CSFlow: Aligning Flow Matching with Human Contrast Sensitivity
Malgorzata Galinska, Bart Pogodzinski, Jan Eric Lenssen
NeurIPS 2026
TL;DR. We improve image flow models without extra compute by prioritizing the generation stages that matter most to human vision.
Abstract. We introduce Contrast Sensitive Flow (CSFlow), a weighting scheme that connects the human eye's Contrast Sensitivity Function (CSF) to the iterative denoising steps of flow matching. Because real-world images concentrate signal at low spatial frequencies, these components reach high signal-to-noise ratio earlier during continuous diffusion than high-frequency components. When generating images with diffusion or flow matching models, this induces a soft autoregressive structure in Fourier space, where coarse image content stabilizes before fine detail. Meanwhile, the human visual system is unequally sensitive to spatial frequencies: very low and very high frequencies require significantly higher contrast to be perceived. We for the first time merge these observations through two contributions: (1) a metric that estimates which frequencies are generated at each reverse flow interval and (2) timestep weights obtained by aligning the frequencies generated at each noise level with human contrast sensitivity. We validate our contributions experimentally showing that these weights can improve generative performance by lowering FID by up to %, increasing Inception Score by up to % and improving GenEval scores by up to % using inference-only timestep modification or short fine-tuning. Qualitatively, we find that our CSFlow weights lead to better visual realism and less cartoonish appearance of generated images. In a two-alternative forced-choice study, participants preferred CSFlow generations over the baseline in % of comparisons.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:43 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
This paper proposes CSFlow, a framework that incorporates the human Contrast Sensitivity Function (CSF) into diffusion and flow-matching models by analyzing the relationship between denoising timesteps and the generated spatial frequencies. The method adjusts timestep weighting during training and inference to improve perceptual quality.
Strengths:
- The paper introduces an interesting connection between human visual perception, spatial frequency generation, and diffusion/flow matching processes.
- The proposed timestep weighting strategy is simple, interpretable, and can be applied without significant architectural modifications.
- The method is evaluated on multiple image generation settings with quantitative and qualitative comparisons against existing weighting approaches.
Weaknesses:
- The reported improvements are relatively modest, and the absence of error bars or statistical significance analysis makes the reliability of the gains unclear.
- The theoretical motivation and implementation details of timestep adjustment require clearer explanation, particularly regarding the role of timesteps in the generative process.
- The method is mainly validated on pixel-space models, and its effectiveness on commonly used latent diffusion or flow-based models remains unclear.
- The human perception motivation is not sufficiently validated through human preference studies or perceptual evaluation.
- Some design choices, such as the interpolation scheme and CSF parameter assumptions, lack sufficient theoretical justification and analysis.
Final justification
The initial reviews were mixed, with scores of 3, 4, and 4. The main concerns were the modest gains without statistical significance analysis, limited validation across model architectures, lack of human perceptual evaluation, sensitivity to CSF/display assumptions, and unclear applicability to latent diffusion models. Following the rebuttal, two reviewers raised their scores, resulting in final scores of 5, 4, and 5. The authors added five-run evaluations with error bars, experiments on PixelREPA showing improved FID, a spectral analysis demonstrating reduced power-spectrum error, and a human study showing a 65% preference for CSFlow. They also clarified the timestep weighting and interpolation scheme, analyzed sensitivity to viewing assumptions, and discussed the current pixel-space scope and possible extensions to latent models.
Overall, the rebuttal and follow-up discussion effectively addressed the main concerns raised during review. The additional statistical, perceptual, and cross-model evidence substantially strengthens the paper, while the remaining limitations primarily concern scope and future extension to latent models. I therefore recommend acceptance.
Read meta-review
Meta-review
This paper proposes CSFlow, a framework that incorporates the human Contrast Sensitivity Function (CSF) into diffusion and flow-matching models by analyzing the relationship between denoising timesteps and the generated spatial frequencies. The method adjusts timestep weighting during training and inference to improve perceptual quality.
Strengths:
- The paper introduces an interesting connection between human visual perception, spatial frequency generation, and diffusion/flow matching processes.
- The proposed timestep weighting strategy is simple, interpretable, and can be applied without significant architectural modifications.
- The method is evaluated on multiple image generation settings with quantitative and qualitative comparisons against existing weighting approaches.
Weaknesses:
- The reported improvements are relatively modest, and the absence of error bars or statistical significance analysis makes the reliability of the gains unclear.
- The theoretical motivation and implementation details of timestep adjustment require clearer explanation, particularly regarding the role of timesteps in the generative process.
- The method is mainly validated on pixel-space models, and its effectiveness on commonly used latent diffusion or flow-based models remains unclear.
- The human perception motivation is not sufficiently validated through human preference studies or perceptual evaluation.
- Some design choices, such as the interpolation scheme and CSF parameter assumptions, lack sufficient theoretical justification and analysis.
Final justification
The initial reviews were mixed, with scores of 3, 4, and 4. The main concerns were the modest gains without statistical significance analysis, limited validation across model architectures, lack of human perceptual evaluation, sensitivity to CSF/display assumptions, and unclear applicability to latent diffusion models. Following the rebuttal, two reviewers raised their scores, resulting in final scores of 5, 4, and 5. The authors added five-run evaluations with error bars, experiments on PixelREPA showing improved FID, a spectral analysis demonstrating reduced power-spectrum error, and a human study showing a 65% preference for CSFlow. They also clarified the timestep weighting and interpolation scheme, analyzed sensitivity to viewing assumptions, and discussed the current pixel-space scope and possible extensions to latent models.
Overall, the rebuttal and follow-up discussion effectively addressed the main concerns raised during review. The additional statistical, perceptual, and cross-model evidence substantially strengthens the paper, while the remaining limitations primarily concern scope and future extension to latent models. I therefore recommend acceptance.
1 comment
- Rating
- 5/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This work addresses the central challenge of allocating flow-matching training/inference effort to perceptually important denoising stages. The paper proposes CSFlow, which estimates which spatial frequencies are generated at each timestep and weights those timesteps using the human contrast sensitivity function. It applies the weights to inference step allocation and short fine-tuning.
Strengths and weaknesses
Strengths:
- Nice idea: connect flow-matching frequency progression with human visual sensitivity.
- Simple plug-in weighting scheme for inference and training.
- Clear derivation of retained signal and CSF-based timestep weights.
- Evaluated on both text-to-image and class-to-image generation.
- Includes comparisons to P2 and MinSNR weighting.
- Qualitative results support the claim of less cartoonish, more realistic texture.
Weaknesses:
- The gains are small: GenEval improves from about 0.794 to 0.812, and FID/IS gains are modest.
- No error bars or statistical significance, despite small metric differences.
- The method is limited to pixel-space models; applicability to common latent diffusion/flow models is unclear.
- The human-perception motivation is not validated with human preference studies.
- The CSF conversion depends on assumed viewing distance and pixel size, but sensitivity to these assumptions is not tested.
- The claims of the paper are somewhat stronger than the evidence, especially “human-aligned” generation.
Questions
- Are the reported GenEval, FID, and IS improvements statistically significant across seeds?
- How sensitive are the weights to viewing distance, pixel size, image resolution, and display assumptions?
- Does CSFlow improve human preference judgments, not just automatic metrics?
- Can the method be extended to latent diffusion/flow models, where spatial frequencies are less directly defined?
- How much of the gain comes from inference weighting versus fine-tuning weighting?
Limitations
No. The paper discusses some limitations, but it should more clearly address lack of statistical significance, lack of human study, sensitivity to CSF/display assumptions, and limited applicability to latent-space models.
Final justification
Thank you for the detailed rebuttal. The repeated evaluations, user study, and additional PixelREPA results address my main concerns, so I am increasing my score from 4 to 5; however, extension to latent models remains future work, and the sensitivity analysis does not yet show that performance remains robust across different display assumptions.
Formatting concerns
None observed.
4 comments
Rebuttal [1/3]
We thank the Reviewer for acknowledging the clear derivation, plug-in simplicity of using the method, the extensiveness of our evaluation. In the following points we address the questions raised by the reviewer.
W1, W2, Q1: Statistical significance
We ensure that our results are statistically significant, by rerunning all the quantitative evaluations 5 times and reporting the means with standard deviations. We show the results in the tables below.
Table 1: PixelGen text-to-image GenEval$\uparrow$ reevaluation, best per method
| Method | Inference-only | Finetuning-only | Finetuning + Inference |
|---|---|---|---|
| Baseline (no reweighting) | 0.791 ± 0.0018 | 0.789 ± 0.0024 | 0.789 ± 0.0024 |
| P2 | 0.792 ± 0.0040 | 0.809 ± 0.0031 | 0.806 ± 0.0005 |
| MinSNR | 0.788 ± 0.0048 | 0.786 ± 0.0011 | 0.788 ± 0.0013 |
| CSFlow (ours) | 0.798 ± 0.0025 | 0.810 ± 0.0004 | 0.813 ± 0.0022 |
Table 2: JiT-H/16 class-to-image FID$\downarrow$ reevaluation, best per method
| Method | Inference-only | Training-only | Training + Inference |
|---|---|---|---|
| Baseline (no reweighting) | 1.89 ± 0.011 | 1.89 ± 0.019 | 1.89 ± 0.019 |
| P2 | 1.84 ± 0.011 | 1.86 ± 0.021 | 1.78 ± 0.015 |
| MinSNR | 1.84 ± 0.011 | 1.90 ± 0.013 | 1.86 ± 0.021 |
| CSFlow (ours) | 1.80 ± 0.010 | 1.89 ± 0.005 | 1.78 ± 0.020 |
Additionally, to show the impact of our method against model diversity, we evaluate our weighted inference applied to PixelREPA-H/16, where we experience larger improvements in FID from 1.81 to 1.59. We use the default inference configuration -- 50 steps with Heun solver. We show the results in the table below.
Table 3: PixelREPA inference weighting results
| Model Variant | FID | |
|---|---|---|
| Original model | -- | 1.81 +- 0.015 |
| P2 inference | 0.5 | 1.62 +- 0.004 |
| MinSNR inference | 0.4 | 1.68 +- 0.009 |
| CSFlow inference (ours) | 0.5 | 1.59 +- 0.005 |
We also rerun the Fig. 7 with error bars, to make sure our conclusions about better applicability of our weights to inference-scaling wasn't due to noise.
Table 3: GenEval$\uparrow$ scores in Figure 7 (timeshift 3.0), original model weights
| Model | =0.0 | =0.1 | =0.2 | =0.3 | =0.4 | =0.5 | =0.6 | =0.7 | =0.8 | =0.9 | =1.0 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Our | 0.791 ± 0.0018 | 0.791 ± 0.0024 | 0.791 ± 0.0026 | 0.789 ± 0.0015 | 0.788 ± 0.0016 | 0.788 ± 0.0025 | 0.791 ± 0.0039 | 0.796 ± 0.0011 | 0.792 ± 0.0035 | 0.794 ± 0.0027 | 0.798 ± 0.0025 |
| MinSNR | 0.791 ± 0.0018 | 0.792 ± 0.0024 | 0.785 ± 0.0023 | 0.786 ± 0.0013 | 0.786 ± 0.0015 | 0.788 ± 0.0023 | 0.792 ± 0.0009 | 0.795 ± 0.0022 | 0.793 ± 0.0026 | 0.783 ± 0.0018 | 0.765 ± 0.0023 |
| P2 | 0.791 ± 0.0018 | 0.791 ± 0.0019 | 0.792 ± 0.0016 | 0.789 ± 0.0028 | 0.792 ± 0.0022 | 0.790 ± 0.0017 | 0.789 ± 0.0010 | 0.792 ± 0.0040 | 0.789 ± 0.0020 | 0.785 ± 0.0009 | 0.778 ± 0.0024 |
Table 4: GenEval$\uparrow$ scores in Figure 7 (timeshift 1.0), original model weights
| Model | =0.0 | =0.1 | =0.2 | =0.3 | =0.4 | =0.5 | =0.6 | =0.7 | =0.8 | =0.9 | =1.0 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Our | 0.791 ± 0.0018 | 0.791 ± 0.0017 | 0.791 ± 0.0022 | 0.792 ± 0.0005 | 0.791 ± 0.0018 | 0.793 ± 0.0013 | 0.792 ± 0.0008 | 0.793 ± 0.0016 | 0.794 ± 0.0034 | 0.794 ± 0.0019 | 0.798 ± 0.0025 |
| MinSNR | 0.791 ± 0.0018 | 0.795 ± 0.0013 | 0.791 ± 0.0004 | 0.793 ± 0.0005 | 0.794 ± 0.0023 | 0.791 ± 0.0007 | 0.786 ± 0.0019 | 0.786 ± 0.0015 | 0.785 ± 0.0021 | 0.773 ± 0.0017 | 0.765 ± 0.0023 |
| P2 | 0.791 ± 0.0018 | 0.791 ± 0.0016 | 0.794 ± 0.0017 | 0.792 ± 0.0027 | 0.791 ± 0.0036 | 0.790 ± 0.0014 | 0.787 ± 0.0013 | 0.784 ± 0.0016 | 0.788 ± 0.0037 | 0.787 ± 0.0028 | 0.778 ± 0.0024 |
Additionally, we show that the distribution of images generated using our method match more closely the radially-averaged power spectrum of real images. We encourage the reviewer to look into our results from Q2 of Reviewer deKT.
We also emphasise that our method qualitatively improves the visual realism, as it was ackgnowledged by the reviewer and validated by our user study (see W4, W6, Q3: User study).
Rebuttal [2/3]
W3, Q4: Extendability to latent diffusion/flow models
The method as-is is directly applicable only to pixel-space diffusion, since the derivation of the weights requires us to know which spectral frequencies are generated at which denoising timestep. This is due to the usage of Contrast Sensitivity Function (CSF), which is defined only for spectral frequencies, and there exists no clear conversion between them and latent frequencies. In most latent diffusion models, only the final clean latent is in distribution for the decoder – decoding and analysing spectra of noisy latent states might be misleading.
We want to highlight, that pixel-space diffusion -- while not currently SOTA on image generation benchmarks -- remains an active direction with large interest from both industry labs as well as academia. The interest in the field is exhibited by recent works such as: SiD2 (Google, CVPR'25), PixelFlow (Adobe/HKU, 2025), JiT (MIT, CVPR'26), and PixelDiT (NVIDIA, CVPR'26 oral), with 2026 follow-ups such as PixelGen and Pixel MeanFlow.
Beyond benchmarks, pixel space avoids lossy VAE round-trips in editing and inpainting and enables exact per-pixel masking (eg. TD-Paint, ICLR'25; RAD, CVPR'25). Additionally, the single-stage training makes it much simpler to identify issue causes than in the two-stage pipeline with AE.
We believe one could apply the CSFlow weights for a latent diffusion model if the latent-space would be “spectrally aligned” with pixel space (a noisy latent would correctly encode low-frequency pixel-space components) -- then one could prioritize some timesteps by either
- Applying the CSFlow weights by modifying the distribution during training of both the autoencoder and the diffusion model,
- Adjust the mapping of latent noise level to frequencies of the AE, so that a fixed in latent space would contribute to an equal CSFlow-weighted information gain in the pixel-space. The re-mapping of the noise levels would be equivalent to our inverse-CDF timestep mapping we already perform in the inference-time CSFlow weighting.
We consider it as an exciting future work direction.
W4, W6, Q3: User study
We strongly agree that a User Study on perceptual quality would strengthen the paper. We designed the following two-stage protocol to quantitatively capture the improved visual realism of geometrically correct generated images:
Stage 1: We presented users with generated images from our best model and the baseline (unpaired), asking them to select those that do not show significant geometric distortions (e.g. missing legs or broken shapes). From the resulting images, we gathered pairs of (baseline, ours) where both were considered geometrically correct. These pairs are the image set for Stage 2.
Stage 2: We presented the pairs gathered in Stage 1 (only consisting of images that are physically plausible and geometrically correct) to the users in random order and image positions and asked for a preference in visual realism. The instruction was to choose an image that the user prefers in terms of its quality, realism and aesthetics. In total, 50 users took part in the study and judged 393 image pairs.
Results: The users preferred our generations over the baseline in 65% of all cases, supporting the improved visual realism of our generations.
Rebuttal [3/3]
W5, Q2: Sensitivity of the CSFlow weights
Our CSFlow weights are dependant on the viewing distance, image size and the image resolution.
Doubling the image size is exactly equivalent to halving the distance to the image (it is the scale ambiguity problem). This operation only impacts the conversion from cycles/degree to cycles/pixels when using the CSF function. Changing those parameters would result in shifting the arguments of the CSF function. It is a multiplicative shift, but CSF is most often visualised with log on X axis, so it would be equivalent to linearly shifting the windows along the CSF weights plot.
When increasing the resolution (and keeping the distance and image size fixed), the SNR of the information from lower frequencies (that were already present in the image) increases, eg. when doubling the resolution, there are now 4 pixels encoding the same coarse information instead of 1. Many papers, eg. SD3 utilized by implementing timeshifting to adjust the schedules for better high-resolution generation. In our case, changing the resolution cannot be directly approximated by the SD3's timeshift, as in our case adding new higher frequencies also modifies the range of arguments to the CSF function, thus we cannot exactly calculate the effect of resolution change on the weights without making strong assumptions about the (empirically estimated) CSF.
Other display settings (such as brightness) should have no impact on the weights, as it would impact contrast of all frequencies at the same time -- thus shall have no effects on the relative weight.
In the table below, we present (1) the original weights that we use for resolution 512x512 with the same assumptions as in the paper, (2) the weights after doubling the image size, (3) after halving the distance to the image and (4) after reducing the image resolution by half (while keeping all other parameters fixed).
Sensitivity of the CSFflow weights
| range | [0.0, 0.2) | [0.2, 0.4) | [0.4, 0.6) | [0.6, 0.8) | [0.8, 1.0) |
|---|---|---|---|---|---|
| 1. Weights 512x512 res | 1.34 | 1.55 | 1.18 | 0.71 | 0.23 |
| 2. 2× image size | 0.84 | 1.31 | 1.29 | 1.03 | 0.53 |
| 3. ½× distance | 0.84 | 1.31 | 1.29 | 1.03 | 0.53 |
| 4. Half res (256) | 0.91 | 1.36 | 1.28 | 0.97 | 0.49 |
One could observe that operations (2) and (3) lead to exactly the same weights, but differ from the weights obtained by resolution change (4).
Q5: Inference weighting vs fine-tuning weighting
In the tables below we show the individual influence of training and inference-time weighing on GenEval (PixelGen XXL) and ImageNet 256 class conditional generation (JiT-H).
Table 2: PixelGen text-to-image GenEval$\uparrow$ reevaluation, best per method
| Method | Inference-only | Finetuning-only | Finetuning + Inference |
|---|---|---|---|
| P2 | 0.792 ± 0.0040 | 0.809 ± 0.0031 | 0.806 ± 0.0005 |
| MinSNR | 0.788 ± 0.0048 | 0.786 ± 0.0011 | 0.788 ± 0.0013 |
| CSFlow (ours) | 0.798 ± 0.0025 | 0.810 ± 0.0004 | 0.813 ± 0.0022 |
Table 3: JiT-H/16 class-to-image FID$\downarrow$ reevaluation, best per method
| Method | Inference-only | Training-only | Training + Inference |
|---|---|---|---|
| Baseline (no reweighting) | 1.89 ± 0.011 | 1.89 ± 0.019 | — |
| P2 | 1.84 ± 0.011 | 1.86 ± 0.021 | 1.78 ± 0.015 |
| MinSNR | 1.84 ± 0.011 | 1.90 ± 0.013 | 1.86 ± 0.021 |
| CSFlow (ours) | 1.80 ± 0.010 | 1.89 ± 0.005 | 1.78 ± 0.020 |
We ask the Reviewer to increase their score, if the questions and weaknesses were addressed appropriately. Otherwise, we happy to engage in further discussion.
References
- [PixelREPA] Shin et al., Representation Alignment for Just Image Transformers is not Easier than You Think, ECCV 2026.
- [SD3] Esser et al., Scaling Rectified Flow Transformers for High-Resolution Image Synthesis, ICML 2024.
- [SiD2] Hoogeboom et al., Simpler Diffusion: 1.5 FID on ImageNet512 with Pixel-space Diffusion, CVPR 2025.
- [PixelFlow] Chen et al., PixelFlow: Pixel-Space Generative Models with Flow, arXiv:2504.07963, 2025.
- [PixelDiT] Yu et al., PixelDiT: Pixel Diffusion Transformers for Image Generation, CVPR 2026.
- [TD-Paint] Mayet et al., TD-Paint: Faster Diffusion Inpainting Through Time Aware Pixel Conditioning, ICLR 2025.
- [RAD] Kim et al., RAD: Region-Aware Diffusion Models for Image Inpainting, CVPR 2025.
Thank you for the detailed rebuttal. The repeated evaluations, user study, and additional PixelREPA results address my main concerns, so I am increasing my score from 4 to 5; however, extension to latent models remains future work, and the sensitivity analysis does not yet show that performance remains robust across different display assumptions.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper presents Contrast Sensitive Flow (CSFlow) that connects the human eye’s Contrast Sensitivity Function (CSF) to the iterative denoising steps of diffusion and flow matching models. Based on the fact that the reverse image generative process of those models is strongly connected to the reconstruction of different spatial frequencies, this approach identifies time intervals that recover spatial frequencies important to human perception in the CSF manner. Then, it weights such time intervals during training and/or inference to generate more realistic images. Experiments show that the proposed method achieves more realistic image generation than the baseline model (PixelGen) and outperforms the existing weighting methods quantitatively.
Strengths and weaknesses
Strengths
- This paper is the first to introduce the concept of human perception (i.e., CSF) into the time step weighting in diffusion and flow matching models and show this effectiveness.
- The proposed weighting approach leads to quantitative improvements in both training-free (inference) and finetuning settings.
- Limitations are well discussed throughout the paper.
Weaknesses
- This paper is hard to follow, especially for the readers unfamiliar with diffusion and flow matching models because it lacks the detailed mathematical explanations (preliminaries) about those models. At least, the role of time steps (time sampling during training or time intervals during inference) in the reverse generative process must be explained deeply in the main paper because the proposed method intervenes these steps directly.
- The proposed approach seems to achieve better results only when using PixelGen models (using JiT-H improves only FID score). Thus, the robustness of the proposed approach against model diversity is unclear.
- The proposed approach is grounded from human perception. Thus, improvements of visual quality are most important and must be discussed more deeply. However, the visual results are compared between the baseline model and that with the proposed approach, no the existing weighting methods (MinSNR and P2). Perhaps, like the human perception experiments, conducting image quality tests by human subjects might make the paper contributions more convincing.
Questions
As I mentioned in the Weaknesses, I am concerned with the following two points.
- The model robustness of the proposed approach. This approach can be applied only in pixel-space diffusion or flow models, which are not mainstream in real applications. Therefore, unless the authors can at least prove that the proposed approach is effective for most pixel-space diffusion or flow models, it will be difficult to present this paper at the top tier level of conference.
- Lack of visual comparison. The proposed approach is based on the concept of human perception, i.e., CSF. Therefore, the reader expects significant improvements of visual quality of generated images. More results and discussions for this point must be needed.
Limitations
yes
Final justification
The authors' rebuttal and comments address my main concerns, so I am increasing my score from 3 to 4. However, as Reviewer Cfch mentioned, extension to latent models and more model diversity (robustness) remain future work. I hope to add preliminary and clarify the relationship between diffusion (and flow) matching models and the proposed method. This highlights the originality of this work.
Formatting concerns
I thought there was nothing in this paper.
5 comments
Rebuttal [1/2]
We thank the reviewer for acknowledging the novelty of our work, as we are the first paper to introduce CSF in image generation models. In this rebuttal, we show stronger significance of our method by including scores with error bars, evaluating our method on an additional model and reporting results of a user study on image preference.
W1: Preliminaries
We apologise for not including the preliminaries on diffusion and flow matching models and not explaining sufficiently the impact of timestep weighting and discretizations in training and inference respectively. We will include this in the final version of the paper.
W2: Robustness against model diversity
FID is widely considered the default metric for evaluating image generation quality, as it directly assesses whether the model correctly models the data distribution. On ImageNet, the FID numbers are quite saturated. For example, our improvement of in FID on JiT-H with our inference-only modification is larger than the jump the original paper has when changing from 953M to 2B parameter model ( FID=). We cannot report GenEval scores (only text-to-image) on JiT-H, as JiT-H cannot be directly applied to text-to-image generation.
To show the impact of our method against model diversity, we further evaluate our weighted inference on PixelREPA-H/16, where we experience even larger improvements in FID from 1.81 to 1.59. We use the default inference configuration -- the 50-step Heun solver with CFG. We show the results in the table below.
Table 3: PixelREPA inference weighting results, best was chosen
| Model Variant | FID | |
|---|---|---|
| Original model | -- | 1.81 +- 0.015 |
| P2 inference | 0.5 | 1.62 +- 0.004 |
| MinSNR inference | 0.4 | 1.68 +- 0.009 |
| CSFlow inference (ours) | 0.5 | 1.59 +- 0.005 |
We will also add standard deviations to all results in the paper. Please refer to first answer to R1 for the actual numbers.
In the response to Reviewer deKT (Q2, Tab. 6) we also show, that our method applied to JiT-H produces images exhibiting power spectrum closer to that of real images -- underlining our improvement on this model.
W3 and Q2: User Study on perceived realism
We strongly agree that a User Study on perceptual quality would strengthen the paper. We designed the following two-stage protocol to quantitatively capture the improved visual realism of geometrically correct generated images:
Stage 1: We presented users with generated images from our best model and the baseline (unpaired), asking them to select those that do not show significant geometric distortions (e.g. missing legs or broken shapes). From the resulting images, we gathered pairs of (baseline, ours) where both were considered geometrically correct. These pairs are the image set for Stage 2.
Stage 2: We presented the pairs gathered in Stage 1 (only consisting of images that are physically plausible and geometrically correct) to the users in random order and image positions and asked for a preference in visual realism. The instruction was to choose an image that the user prefers in terms of its quality, realism and aesthetics. In total, 50 users took part in the study and judged 393 image pairs.
Results: The users preferred our generations over the baseline in 65% of all cases, supporting the improved visual realism of our generations.
Rebuttal [2/2]
Q1: Model robustness and Latent Models
The method as-is is directly applicable only to pixel-space diffusion, since the derivation of the weights requires us to know which spectral frequencies are generated at which denoising timestep. This is due to the usage of Contrast Sensitivity Function (CSF), which is defined only for spectral frequencies, and there exists no clear conversion between them and latent frequencies. In most latent diffusion models, only the final clean latent is in-distribution for the decoder -- thus decoding and analysing spectra of the noisy latent states might be misleading.
We want to highlight, that pixel-space diffusion -- while not currently SOTA on image generation benchmarks -- remains an active direction with large interest from both industry labs as well as academia. The interest in the field is exhibited by recent works such as: SiD2 (Google, CVPR'25), PixelFlow (Adobe/HKU, 2025), JiT (MIT, CVPR'26), and PixelDiT (NVIDIA, CVPR'26 oral), with 2026 follow-ups such as PixelGen and Pixel MeanFlow.
Beyond benchmarks, pixel space avoids lossy VAE round-trips in editing and inpainting and enables exact per-pixel masking (eg. TD-Paint, ICLR'25; RAD, CVPR'25). Additionally, the single-stage training makes it much simpler to identify issue causes than in the two-stage pipeline with AE.
As mentioned before, we extend our evaluation to show that our method significantly outperforms base JiT-H in terms of FID (from 1.89 to 1.78), and models more accurately the frequency power spectrum of real images. We also show that our inference can greatly improve the performance on other methods, such as PixelREPA, where we reduce the FID from 1.81 to 1.59 using our weighted inference. Our method is architecture agnostic, and could be applied to any diffusion and flow models denoising in pixel-space.
We believe one could apply the CSFlow weights for a latent diffusion model if the latent-space would be “spectrally aligned” with pixel space (a noisy latent would correctly encode low-frequency pixel-space components) -- then one could prioritize some timesteps by either:
- Applying the CSFlow weights by modifying the distribution during training of both the autoencoder and the diffusion model,
- Adjust the mapping of latent noise level to frequencies of the AE, so that a fixed in latent space would contribute to an equal CSFlow-weighted information gain in the pixel-space. The re-mapping of the noise levels would be equivalent to our inverse-CDF timestep mapping we already perform in the inference-time CSFlow weighting.
We consider it as an exciting future work direction.
We ask the Reviewer to increase their score, if the questions and weaknesses were addressed appropriately. Otherwise, we happy to engage in further discussion.
References
- [PixelREPA] Shin et al., Representation Alignment for Just Image Transformers is not Easier than You Think, ECCV 2026.
- [SD3] Esser et al., Scaling Rectified Flow Transformers for High-Resolution Image Synthesis, ICML 2024.
- [SiD2] Hoogeboom et al., Simpler Diffusion: 1.5 FID on ImageNet512 with Pixel-space Diffusion, CVPR 2025.
- [PixelFlow] Chen et al., PixelFlow: Pixel-Space Generative Models with Flow, arXiv:2504.07963, 2025.
- [PixelDiT] Yu et al., PixelDiT: Pixel Diffusion Transformers for Image Generation, CVPR 2026.
- [TD-Paint] Mayet et al., TD-Paint: Faster Diffusion Inpainting Through Time Aware Pixel Conditioning, ICLR 2025.
- [RAD] Kim et al., RAD: Region-Aware Diffusion Models for Image Inpainting, CVPR 2025.
Dear Reviewer,
We're very thankful for your time and constructive feedback. We would greatly appreciate any early feedback on our rebuttal, as this would allow us to provide further explanations or small experiments that may support your judgment.
- Rating
- 5/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The authors incorporate human visual perception, particularly the contrast sensitivity function towards improving diffusion image synthesis with flow matching, identifying an uneven distribution of spatial frequency matching along the timeline of diffusion, and using this to adjust the scheduler. Images generated with this new method are presented and show good synthesis results.
Strengths and weaknesses
Strengths:
- This paper addresses an important, timely, and active area of research, improving the quality of diffusion generated images by improving flow-based schedulers.
- The paper contains a well-written introduction and comprehensive overview of related prior work.
- The authors develop an elegant framework linking three distinct fields: human perception, image statistics, and diffusion models, and the use of human visual perception to improve diffusion is exciting. In particular, as the authors claim “[they] are the first to explicitly describe which frequencies are being generated at specific t’s” and the perceptual importance of said signal gain.
- The authors report significant quantitative and qualitative experiments to verify their claims
Weaknesses:
- The central claims of improved performance are not substantiated. Because the reported gains are modest (2.2% - 4.7%), and reported without error bars or confidence, I remain unconvinced that these are true improvements. This is compounded by the choice of as Fig. 7 appears noisy and also absent any confidence intervals. I do not believe the results presented demonstrate that the settings are anything beyond artifacts of noise.
- The interpolation scheme (Eq. 8), appears to be an ad hoc introduction of a tunable parameter (or even worse, a way to cherry-pick noisy results). Unlike the CSF weighting, its necessity is not theoretically justified by the authors.
- Neither of the baseline comparisons, P2 nor Min-SNR, were designed to be time-step schedulers, but instead to improve training. Repurposing their weighting curves as inference grids, and furthermore modifying them with the authors’ own interpolation scheme, does not constitute a fair comparison.
- The central method used to modify the timesteps such that they are inversely proportional to the CDF of the weighting should be presented in the main text and not left in the appendix. Minor: "a a frequency” (Line 152)
Questions
- Are the central claims of improved performance actually significant quantitatively in the context of rigorous error analysis? Without this, while the method is interesting, it is unclear how important or impactful the results truly are.
- Do denser sampling in timesteps with greater perceptually weighted signal gain actually help to “reconstruct these frequencies”? For example would reproducing Figure 3 with a CSFlow weighted time steps show an increase in signal gain in these perceptually important frequencies? A central theme of the paper is how to allocate a limited inference-time computational budget on image reconstruction.
- Have the authors considered using diagnostically to compare agains various variants of diffusion models? Since the output of latent diffusion models are still images, can be calculated for most modern diffusion models as well.
- Relatedly, have the authors considered using as an objective function rather than a weighting? It would be an exciting addition to show the weighting or time-steps such that the resulting could be learned such that it is equalized across all time-steps.
Limitations
yes.
Final justification
In light of the new experiments and explanations made by the authors in the last round of rebuttal period, and the confirmation regarding the human subjects protocol adherence, I raise my score to a 5.
Formatting concerns
none
9 comments
Rebuttal [1/3]
We thank the Reviewer for acknowledging the elegance of our framework. We believe that beyond the theoretical contribution of providing a useful metric tying the spectral frequencies of an image to the diffusion timesteps, our practical contribution -- timestep weights based on the Contrast Sensitivity Function -- yields clear improvement on image distribution modelling (FID), prompt-following accuracy (GenEval), as well as qualitatively (as on Fig. 5). In the rebuttal, we show that our advantage is statistically significant, and extend the experiments to quantitatively show that our method improves modelling of the relevant frequencies. Additionally, we validate our claims on the improved perceptual quality using a user study.
W1 and Q1: Statistical Significance
Regarding W1 and Q1, we reevaluated our models, as well as all the baselines 5 times with different seeds. Below we report our main paper results with standard deviations. We will add them to the paper as well.
Table 1: PixelGen text-to-image GenEval$\uparrow$ reevaluation, best per method
| Method | Inference-only | Finetuning-only | Finetuning + Inference |
|---|---|---|---|
| Baseline (no reweighting) | 0.791 ± 0.0018 | 0.789 ± 0.0024 | 0.789 ± 0.0024 |
| P2 | 0.792 ± 0.0040 | 0.809 ± 0.0031 | 0.806 ± 0.0005 |
| MinSNR | 0.788 ± 0.0048 | 0.786 ± 0.0011 | 0.788 ± 0.0013 |
| CSFlow (ours) | 0.798 ± 0.0025 | 0.810 ± 0.0004 | 0.813 ± 0.0022 |
Table 2: JiT-H/16 class-to-image FID$\downarrow$ reevaluation, best per method
| Method | Inference-only | Training-only | Training + Inference |
|---|---|---|---|
| Baseline (no reweighting) | 1.89 ± 0.011 | 1.89 ± 0.019 | 1.89 ± 0.019 |
| P2 | 1.84 ± 0.011 | 1.86 ± 0.021 | 1.78 ± 0.015 |
| MinSNR | 1.84 ± 0.011 | 1.90 ± 0.013 | 1.86 ± 0.021 |
| CSFlow (ours) | 1.80 ± 0.010 | 1.89 ± 0.005 | 1.78 ± 0.020 |
Table 3: GenEval$\uparrow$ scores in Figure 7 (timeshift 3.0), original model weights
| Model | =0.0 | =0.1 | =0.2 | =0.3 | =0.4 | =0.5 | =0.6 | =0.7 | =0.8 | =0.9 | =1.0 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Our | 0.791 ± 0.0018 | 0.791 ± 0.0024 | 0.791 ± 0.0026 | 0.789 ± 0.0015 | 0.788 ± 0.0016 | 0.788 ± 0.0025 | 0.791 ± 0.0039 | 0.796 ± 0.0011 | 0.792 ± 0.0035 | 0.794 ± 0.0027 | 0.798 ± 0.0025 |
| MinSNR | 0.791 ± 0.0018 | 0.792 ± 0.0024 | 0.785 ± 0.0023 | 0.786 ± 0.0013 | 0.786 ± 0.0015 | 0.788 ± 0.0023 | 0.792 ± 0.0009 | 0.795 ± 0.0022 | 0.793 ± 0.0026 | 0.783 ± 0.0018 | 0.765 ± 0.0023 |
| P2 | 0.791 ± 0.0018 | 0.791 ± 0.0019 | 0.792 ± 0.0016 | 0.789 ± 0.0028 | 0.792 ± 0.0022 | 0.790 ± 0.0017 | 0.789 ± 0.0010 | 0.792 ± 0.0040 | 0.789 ± 0.0020 | 0.785 ± 0.0009 | 0.778 ± 0.0024 |
Table 4: GenEval$\uparrow$ scores in Figure 7 (timeshift 1.0), original model weights
| Model | =0.0 | =0.1 | =0.2 | =0.3 | =0.4 | =0.5 | =0.6 | =0.7 | =0.8 | =0.9 | =1.0 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Our | 0.791 ± 0.0018 | 0.791 ± 0.0017 | 0.791 ± 0.0022 | 0.792 ± 0.0005 | 0.791 ± 0.0018 | 0.793 ± 0.0013 | 0.792 ± 0.0008 | 0.793 ± 0.0016 | 0.794 ± 0.0034 | 0.794 ± 0.0019 | 0.798 ± 0.0025 |
| MinSNR | 0.791 ± 0.0018 | 0.795 ± 0.0013 | 0.791 ± 0.0004 | 0.793 ± 0.0005 | 0.794 ± 0.0023 | 0.791 ± 0.0007 | 0.786 ± 0.0019 | 0.786 ± 0.0015 | 0.785 ± 0.0021 | 0.773 ± 0.0017 | 0.765 ± 0.0023 |
| P2 | 0.791 ± 0.0018 | 0.791 ± 0.0016 | 0.794 ± 0.0017 | 0.792 ± 0.0027 | 0.791 ± 0.0036 | 0.790 ± 0.0014 | 0.787 ± 0.0013 | 0.784 ± 0.0016 | 0.788 ± 0.0037 | 0.787 ± 0.0028 | 0.778 ± 0.0024 |
In addition to the small but significant quantitative gains, we strongly believe that our weighting leads to clear qualitative improvements and encourage the reviewer to zoom into Fig. 5 for an impression. To support this quantitatively, we conducted a user study and found that viewers prefer our generations over the baseline in 65% of the cases (see answer to R. bhRH for a detailed description of the study).
Rebuttal [2/3]
W2: Interpolation Parameter
We would like to point out that even without the interpolation scheme, our weighting scheme improves over baselines in two of the three cases. Below we present GenEval results without interpolation ().
Table 5: GenEval$\uparrow$ scores without interpolation
| Method | Inference-only | Finetuning-only | Finetuning + Inference |
|---|---|---|---|
| Baseline (no reweighting) | 0.791 ± 0.0018 | 0.789 ± 0.0024 | 0.789 ± 0.0024 |
| P2 | 0.778 ± 0.0024 | 0.809 ± 0.0031 | 0.806 +- 0.0005 |
| MinSNR | 0.765 ± 0.0023 | 0.786 ± 0.0011 | 0.758 +- 0.0026 |
| CSFlow (ours) | 0.798 ± 0.0025 | 0.810 ± 0.0004 | 0.797 +- 0.0011 |
We found that the proposed interpolation can improve results of our method as well as P2 and MinSNR further. This can be considered our contribution. To enable fair comparison, we chose the best configuration for each method in the main paper.
As justification for the weighting, we point to the following discussion:
While some frequencies might be irrelevant for the human eye (and thus are heavily down-weighted by our method), they might still be relevant for the flow model itself. For example, if very low frequencies are not modelled correctly (eg. images are often too bright, too blue, etc.) then, in intermediate denoising states, the noisy image might become out of distribution for the model.
Furthermore, with inference-only weights, the benefit of making smaller steps in a complex region is bounded by the quality of the flow learned by the model – thus beyond some point, making smaller steps will bring no added value. On the other hand, reducing step-density in simple time regions might have additional detrimental effect, since the inference paths in flow matching are often not straight. Thus, making very large denoising steps in simple regions (or those where not-important spectral frequencies are being generated) might outweigh the benefit of doing smaller steps in important regions.
That is why we believe it is justified to consider adjusting the strength of weighting using our parameters.
W3: Setups of Previous Works
We like to point out that we are the first method that proposes inference step sizes for alignment with human perception. We outperform the uniform baseline weights clearly in all setups, as can be seen in Tables 1 and 2.
Due to the lack of existing works with this goal, we decided to adapt training time methods (P2 and MinSNR) to inference as well, using our conversion. Our method clearly outperforms them in the inference only setting. Therefore, we would disagree with the statement that our comparisons are not fair. In fact, we believe we have been fairer than we had to be.
Further, in Tables 1 and 2 we provide fair comparisons individually ablating the weighting during training against original logit-normal weights, P2 and MinSNR, where ours is better in most cases.
Overall, we believe our experiments sufficiently show the individual and combined improvement of our training- and inference-time weighting. We outperform most of the training-only schemes of previous works in their original setup. We further adapt them to inference and clearly outperform them there as well. While in comparison with P2, our method is not always better, we still provide the formally more grounded method.
W4 and W5
We thank the reviewer for the suggestion and the correction -- we will make sure to move the inference-time weighting to the main paper and correct the mentioned mistake.
Rebuttal [3/3]
Q2: Frequency Reconstruction Analysis
We analyse how our method improves the generation of individual frequencies. We first analyse the radially averaged power spectral density (RAPSD) of the dataset and the generated images -- and measure the log-space error of the power spectrum, between the RAPSD of the data and one of the methods (baseline and ours). We show that in the frequency range around the peak CSF, our RAPSD log space error is smaller, indicating that CSFlow meaningfully improves the modelling of the marginal power spectrum. The results are presented in the table below (lower error is better).
Table 6: Log-space RAPSD error for different frequency ranges
| frequency (1/pixel) | 1/128 | 1/64 | 1/32 | 1/16 | 1/8 | 1/4 |
|---|---|---|---|---|---|---|
| CSF, relative to the peak | 0.54 | 0.85 | 1.00 | 0.83 | 0.47 | 0.17 |
| baseline | 0.0668 ± 0.0020 | 0.0670 ± 0.0021 | 0.0709 ± 0.0013 | 0.0553 ± 0.0015 | 0.0626 ± 0.0014 | 0.2874 ± 0.0028 |
| Ours finetune + inference | 0.0661 ± 0.0005 | 0.0554 ± 0.0022 | 0.0477 ± 0.0035 | 0.0271 ± 0.0035 | 0.0364 ± 0.0018 | 0.2697 ± 0.0057 |
| difference | −0.0006 | −0.0116 | −0.0233 | −0.0282 | −0.0262 | −0.0177 |
We used 5 runs to estimate the mean and standard deviation of the scores. Both analyses have been conducted on ImageNet-256 using fine-tuned JiT-H. We used baseline model finetuned for equal number of steps as ours, with uniform inference grid. For ours, we chose our CSFlow-weighted JiT-H model which performed best in terms of FID.
We observe that this table is hard to parse. If the reviewers request it, we are also happy to provide these results as plot figures. However, without an explicit request, the guidelines prevent adding such a link. We will provide the figure in the revised paper version.
Q3: Latent Models: Applicability of the CSFlow weights
We want to highlight, that pixel-space diffusion -- while not currently SOTA on image generation benchmarks -- remains an active direction with large interest from both industry labs as well as academia. The interest in the field is exhibited by recent works such as: SiD2 (Google, CVPR'25), PixelFlow (Adobe/HKU, 2025), JiT (MIT, CVPR'26), and PixelDiT (NVIDIA, CVPR'26 oral), with 2026 follow-ups such as PixelGen and Pixel MeanFlow.
Beyond benchmarks, pixel space avoids lossy VAE round-trips in editing and inpainting and enables exact per-pixel masking (eg. TD-Paint, ICLR'25; RAD, CVPR'25). Additionally, the single-stage training makes it much simpler to identify issue causes than in the two-stage pipeline with AE.
Q4: Latent Models: weight in the objective function
We could apply the CSFlow weights for a latent diffusion model if the latent-space would be “spectrally aligned” with pixel space (a noisy latent would correctly encode low-frequency pixel-space components) -- then one could prioritize some timesteps by either
- Applying the CSFlow weights by modifying the distribution during training of both the autoencoder and the diffusion model
- Adjust the mapping of latent noise level to frequencies of the AE, so that a fixed in latent space would contribute to an equal CSFlow-weighted information gain in the pixel-space. The re-mapping of the noise levels would be equivalent to our inverse-CDF timestep mapping we already perform in the inference-time CSFlow weighting.
We thank the reviewer for the suggestion, as we believe this could be an exciting venture for future work.
We ask the Reviewer to increase their score, if the questions and weaknesses were addressed appropriately. Otherwise, we happy to engage in further discussion.
References
- [PixelREPA] Shin et al., Representation Alignment for Just Image Transformers is not Easier than You Think, ECCV 2026.
- [SD3] Esser et al., Scaling Rectified Flow Transformers for High-Resolution Image Synthesis, ICML 2024.
- [SiD2] Hoogeboom et al., Simpler Diffusion: 1.5 FID on ImageNet512 with Pixel-space Diffusion, CVPR 2025.
- [PixelFlow] Chen et al., PixelFlow: Pixel-Space Generative Models with Flow, arXiv:2504.07963, 2025.
- [PixelDiT] Yu et al., PixelDiT: Pixel Diffusion Transformers for Image Generation, CVPR 2026.
- [TD-Paint] Mayet et al., TD-Paint: Faster Diffusion Inpainting Through Time Aware Pixel Conditioning, ICLR 2025.
- [RAD] Kim et al., RAD: Region-Aware Diffusion Models for Image Inpainting, CVPR 2025.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
We thank the AC for the thoughtful meta-review. During the rebuttal period, we substantially expanded the empirical evaluation and clarified several aspects of the paper. We have responded in detail to each reviewer’s comments in their respective discussion threads. To summarize how we addressed the main concerns:
The new revision will add diffusion/flow-matching preliminaries, and move the inverse-CDF timestep allocation to the main paper. We hope these additions address the main concerns highlighted in the meta-review, and we look forward to the further discussion.