Unsupervised Physics Informed Decomposition of Incomplete Time-Resolved Spectroscopy
Tom Muir, Qifeng Liu, Mohammadrahim Kazemzadeh, William Mills, Ales Leonardis, Huabing Yin, Alexander Krull
NeurIPS 2026
TL;DR. An unsupervised physics-informed VAE recovers Raman spectra from short, incomplete fluorescence-bleaching time series, modelling decay and noise, and outperforms state-of-the-art methods on real cell data and multiple simulated benchmarks.
Abstract. Raman spectroscopy is often hindered by strong autofluorescence backgrounds and noise. While methods for computational removal exist, better results are often achieved through a time-intensive process of waiting for fluorescence to bleach before recording the Raman spectrum. Here, we instead show that short, incomplete recordings of the bleaching process already contain enough information to recover the underlying Raman signal. We present the first unsupervised model that operates on short, incomplete, variable-length sequences of time-resolved measurements, decomposing them into Raman spectra and autofluorescence components while simultaneously removing measurement noise. Our VAE-based method simultaneously learns (i) a bank of fluorophore spectra comprising the baseline, (ii) possible peak positions and shapes, (iii) a model of the measurement noise, and (iv) neural networks for the decomposition of Raman spectra and decay behaviour. We evaluate our method on spectral reconstruction and downstream peak detection, where it outperforms state-of-the-art approaches on multiple simulated benchmarks as well as on a newly collected real-world dataset of spectral time series. We further show that normally disregarded fluorescence decay dynamics themselves may contain discriminative information that can be exploited in future work.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:43 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
This paper introduces a physics-informed VAE for the unsupervised decomposition of incomplete Raman photobleaching time series. It is a well motivated problem with potential application to high-throughput settings. All reviewers seem to agree that the paper has some novelties and thus give positive ratings. The paper could benefit from better designed experimental evaluation.
Final justification
The author rebuttal addressed the concerns raised in the original reviews. All reviewers still feel positively about this paper.
Read meta-review
Meta-review
This paper introduces a physics-informed VAE for the unsupervised decomposition of incomplete Raman photobleaching time series. It is a well motivated problem with potential application to high-throughput settings. All reviewers seem to agree that the paper has some novelties and thus give positive ratings. The paper could benefit from better designed experimental evaluation.
Final justification
The author rebuttal addressed the concerns raised in the original reviews. All reviewers still feel positively about this paper.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
Summary This manuscript introduces LUMOS, a VAE-based framework designed to decompose time-resolved Raman spectroscopy into Raman peaks, distinct fluorescent components, and noise. The authors position this work as the first to address short, incomplete bleaching sequences in an unsupervised fashion. Evaluation on both simulated and real-world datasets demonstrates performance gains over algorithmic baselines (AirPLS, iModPoly) and certain supervised alternatives.
Strengths and weaknesses
Strengths (1) The work addresses a highly practical challenge in Raman spectroscopy—reducing acquisition time by leveraging partial bleaching dynamics. This has clear applicability to high-throughput settings. (2) The integration of domain-specific physics (Voigt profiles, exponential decay) with a probabilistic latent-variable model is logically consistent and well-motivated.
Weaknesses (1) Incremental Methodological Contribution: My primary concern lies in the novelty of the approach. LUMOS effectively aggregates several established components: a standard VAE backbone, a physics-informed decoder, fixed Voigt parameterizations, exponential decay kinetics, and a Poisson-Gaussian noise model. While the engineering required to unify these elements for Raman data is non-trivial, the core machine learning methodology feels evolutionary. The manuscript acknowledges similarities to prior physics-informed autoencoders; however, the shift to a VAE framework and the inclusion of temporal bleaching sequences do not constitute a fundamental architectural or theoretical advance. (2) Potential Evaluation Bias: The synthetic data generation pipeline appears to mirror LUMOS’s internal generative assumptions (exponential decay, specific fluorophore mixtures, Voigt peaks, and Poisson-Gaussian noise). This alignment likely grants the model an inherent advantage. A stronger evaluation would include significant model mismatch scenarios. Without such analyses, it is difficult to determine whether the gains arise from genuine robustness or from matching the simulation assumptions. (3) Limitations of Real-World Validation: The real-data experiments rely on a relatively small set (266 filtered sequences across four classes). More critically, the "ground truth" Raman spectra used for benchmarking are derived from post-processed late-frame averages (baseline corrected and smoothed). Since this reference is itself an estimate rather than a true physical ground truth, the reported quantitative improvements on real data should be interpreted cautiously. (4) The Nature of "Unsupervised" Learning: The emphasis on "unsupervised" training is somewhat misleading. The model incorporates strong physical priors, including a fixed number of fluorophores, pre-defined peak shapes, and noise distributions. It is worth discussing how the method remains "unsupervised" when so many hyperparameters require expert tuning. Additionally, the manuscript does not convincingly demonstrate a scenario where this approach succeeds where supervised methods fail.
Questions
Questions (1) Can the authors clarify what they consider the primary methodological novelty beyond combining existing VAE frameworks with established Raman physics models? (2) How sensitive is LUMOS to violations of the exponential bleaching assumption? (3) Have the authors evaluated the model under realistic distribution shifts where fluorophore spectra or bleaching dynamics differ substantially from the training data?
Limitations
Yes
Formatting concerns
No
2 comments
Appologies for the missing citations
Unfortunately we forgot to include the references in the section 'Evaluation bias and robustness to model mismatch'. The missing references are [1] and [WR96, IAD12] from the main paper.
[1]: Fitzgerald, Sean, Eric Marple, and Anita Mahadevan-Jansen. "Performance assessment of probe-based Raman spectroscopy systems for biomedical analysis." Biomedical Optics Express 14.7 (2023): 3597-3609.
- Rating
- 5/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper introduces LUMOS, a physics-informed VAE for the unsupervised decomposition of incomplete Raman photobleaching time series. The method decomposes a short, temporally decaying sequence of spectra into a single constant Raman spectrum and several exponentially decaying fluorophore components, while jointly estimating measurement noise—thereby recovering the Raman signal without waiting for the fluorescence to bleach fully. The authors evaluate spectral reconstruction and downstream peak detection on four synthetic datasets and one real-world human-cell dataset, reporting improvements over both traditional algorithmic methods and the supervised method RADAR. They also release the new dataset and present preliminary evidence that fluorophore decay dynamics may themselves carry discriminative information complementary to the Raman spectrum.
Strengths and weaknesses
Strengths
-
Real and important motivation. The time cost of complete photobleaching is a well-recognized point in Raman spectroscopy.
-
A genuinely unsupervised setting. The model never observes a clean Raman spectrum; it relies solely on the physical contrast that the signal is constant while fluorescence decays over time. This avoids any dependence on paired ground truth or on the distribution of simulated training data, making the setup closer to real deployment than many supervised methods.
-
Physics-informed design yields a strong inductive bias and data efficiency. Constraining the generative process explicitly to "Voigt peaks + several exponentially decaying fluorophores + signal-dependent noise" allows the method to train from as few as ~240 measurements and to handle variable-length sequences.
-
Reasonably broad evaluation that treats baselines fairly. Comparisons span four synthetic datasets and one real dataset across both reconstruction and peak-detection tasks.
Weaknesses
-
The central claim of time savings lacks direct experimental evidence. The paper repeatedly asserts that high-quality spectra can be obtained using "a fraction of the typical acquisition time," yet never performs a head-to-head wall-clock comparison (full bleaching protocol vs. LUMOS short-sequence acquisition). The sequence-length ablation (Fig. 4, left) measures the number of frames rather than time and cannot substitute for this argument; the only quantified "speed" is the 6.6 ms inference compute time, which is a different axis from acquisition-time savings.
-
Absence of a non-amortized (per-sample optimization) baseline makes the neural network's contribution impossible to assess. All current comparisons are either different methods (polynomial baseline removal, supervised RADAR) or variants of the authors' own hyperparameters. To separate the contribution of the physics model from that of amortized learning / the shared fluorophore bank, a comparison is needed against directly optimizing the same forward model (Eqs. 1–3) per sample, without the network. Such a baseline is not difficult to implement, and its absence leaves the fundamental question of why machine learning is needed experimentally unanswered.
-
No evaluation of fluorophore-component recovery on synthetic data. In the synthetic data, the fluorophore spectra, abundances , and decay rates are all known ground truth, yet the paper evaluates only the Raman spectrum quantitatively (Tables 1–2) and does not use these ground-truth values to verify whether the decomposition is correct. Given the identifiability (permutation/scale) ambiguity of the K-component decomposition, this is precisely where synthetic data should have been leveraged.
-
K (the number of fluorophore slots = 16) is a fixed hyperparameter without a sensitivity analysis. The ablations cover only sequence length, regularization, and noise, but not the value of K; when the true number of fluorophore components is unknown, the justification for this upper bound is unsupported.
Questions
- Is the strong performance of LUMOS driven primarily by training across samples jointly (amortized learning with a shared, globally learned fluorophore bank) or by the physics-informed forward model (the explicit Voigt-peak + multiple-exponential-decay + signal-dependent-noise parameterization)?
- What experiments does shorter acquisition actually unlock that are currently impractical? How easily could another lab adopt this method? Specifically, what minimum hardware and data would a new lab need, and does the learned fluorophore bank transfer across instruments and sample types, or must it be retrained for each new dataset?
Limitations
Yes.
Final justification
Sorry, I chose the wrong contribution type. I fixed it. Thanks for the detailed rebuttal. My concerns are resolved. I think the approach is useful and clearly written. I increased my score from 4 to 5.
Formatting concerns
NA
1 comment
Rebuttal
We thank the reviewer for their insightful feedback. We will address the points below.
'The central claim of time savings lacks direct experimental evidence':
We appreciate the reviewer highlighting that the frame count needs to be tied explicitly to the required acquisition time and would like to clarify this. Photobleaching is a side effect of the same laser used for measurement, so acquiring a time-resolved sequence takes no longer than a conventional measurement. A single exposure of duration corresponds exactly to multiple shorter consecutive acquisitions with the same combined acquisition time, as there is negligible dead time between acquisitions. The total required time for a measurement series of fixed acquisitions is therefore directly proportional to the frame count. Considering the results in Figure 4, our model using 4 (0.4s) measurements still outperforms traditional methods using a single acquisition equivalent to 64 (6.4s) short exposures. This amounts to a 16-fold reduction in acquisition time. Importantly, this time saving compounds when hundreds or thousands of spectra are to be acquired.
'Absence of a non-amortized (per-sample optimization) baseline':
We strongly agree with the reviewer that a comparison with a non-amortized baseline is important. As such, we directly optimized parameters per sample in the cancer dataset. While LUMOS achieves a Pearson correlation of 0.93 for the predicted Raman spectrum, the direct optimization yields a score of 0.49; and 0.68 when providing the true sample fluorophores. Only when we additionally provide the true decay rates and abundances for each sample did the direct fitting achieve similar correlation as LUMOS (0.91). Note that this latter case is highly unrealistic and effectively already removes the baseline, leaving the trivial task of fitting the Raman residual.
While LUMOS’ VAE-based architecture can learn a prior distribution of which patterns and correlations are likely to occur in the data by combining information from the whole training set, the non-amortized fitting does not have this benefit and has to separately process each sample, resulting in inferior results.
Evaluation of fluorophore-component recovery on synthetic data:
We thank the reviewer for this suggestion and have run the requested analysis using two settings with K=4 and K=16 fluorophores on the cancer dataset. During evaluation, we match predicted to ground-truth fluorophores by Hungarian assignment on cosine similarity, resolving the permutation ambiguity.
On a realistic library of 4 random fluorophores, LUMOS is able to reasonably recover the fluorophore spectra, abundances, and decay rates. We achieve a Pearson correlation of r = 0.97 between learned and true spectra and recover abundances at r = 0.79 and decay rates at r = 0.71. When supplying the ground-truth dictionary of fluorophore spectra in place of the learned bank, performance increases only modestly (abundance r = 0.82; decay r = 0.77), indicating that the learned fluorophores are close to the ceiling set by a perfect dictionary and are not the limiting factor at this scale.
When considering the more adversarial 16-fluorophore setting, spectral matching remains reasonable (mean r=0.90) but component-wise recovery degrades (abundance r = 0.24; decay r = 0.22).
Again, this is not a limitation of spectral learning: supplying the exact ground-truth dictionary, which removes spectral matching as a factor entirely, leaves recovery no better than predicting the mean (abundance r = 0.32; decay r = 0.40). The bottleneck is therefore the prediction of abundances and decay rates rather than spectral estimation. In a setting with large K, many almost equivalent combinations of fluorophores in each sample become possible, each of them explaining the data similarly well. While it achieves highly competitive results regarding the quality of the recovered Raman spectra, the predicted abundances and decay rates become less accurate. However, as we show in Figure 5, despite not precisely corresponding to true abundances/decay rates, the predicted values still contain meaningful biological information.
We believe that future work could address this problem of overparameterization by introducing an additional regularization of the predicted abundances. Furthermore, while real acquisitions could be expected to contain associations (particular fluorophores recurring in particular sample types with characteristic kinetics and Raman spectra), which could be exploited by the model, our simulation samples fluorophores independently from the Raman spectrum, thus making the recovery task more challenging. A more sophisticated simulation approach in future work may further investigate the performance under these more realistic conditions.
'The number of fluorophore slots is a fixed hyperparameter without a sensitivity analysis':
We thank the reviewer and have run the requested analysis. Over K = 4, 8, 16 and 32 we obtain Pearson correlations on the estimated Raman spectrum of 0.73, 0.91, 0.92 and 0.92 respectively. Performance is stable for K of 8 and above; the lower value at K = 4 reflects too few slots to represent the fluorophore diversity. Notably, performance is already strong at K = 8 and saturates, indicating that the method is not sensitive with respect to this hyperparamter, allowing for a simple choice of K as long as it is large enough.
Questions
Q1. 'Is LUMOS' performance driven primarily by amortized learning with a fluorophore bank or the physics-informed model?'
We hope we have addressed the reviewer’s concerns in our response to weakness 2.
Q2. 'What experiments does shorter acquisition unlock that are currently impractical?'
Faster acquisition is particularly valuable in Raman imaging, where low Raman intensity and limited SNR and extensive measurement time are the principal bottlenecks. It would enable faster spatial mapping, imaging of dynamic or live samples, and reduced motion, photobleaching and photodamage.
Q3. How easily could another lab adopt this method - what minimum hardware and data would a new lab need?
LUMOS requires only a standard confocal Raman microscope capable of short, repeated exposures. Our real data were acquired with 532nm excitation (~6.2 mW at the sample through a 100x/0.9 NA objective), a 600 grooves/mm grating, and an Andor Kymera 328i spectrometer with a Newton EMCCD detector, at 0.1s per frame. None of these is specialized beyond a conventional Raman setup. Critically, because the method is fully unsupervised, no paired or labeled ground truth data is required: adoption of our technique only requires unlabeled bleaching sequences, of which our results use approximately 240. This makes our barrier to adoption low relative to supervised approaches, which require curated clean or paired references that do not exist for live-cell Raman.
Q4. Does the learned fluorophore bank transfer across instruments and sample types, or must it be retrained for each new dataset?
The physics parameterization makes the model's transfer behavior interpretable rather than a black box, since its parameters separate into sample-intrinsic and instrument-specific groups. The Lorentzian widths of the Voigt peaks are properties of the sample's molecular vibrations and are therefore instrument-independent. The Gaussian component models the instrument response function, and the Poisson-Gaussian noise terms model the detector; these are the instrument-specific parameters that would require refitting on a new setup. The fluorophore bank transfers to the extent that new samples share similar fluorophores, and could be adapted where there is partial overlap. Because fluorescence features are broad and smooth relative to the narrow Raman peaks, the bank is expected to be relatively robust to modest differences in spectral resolution.
We have not evaluated cross-instrument transfer directly, and see this, along with a qualitative analysis of generalization to similar samples, as a clear next step once suitable data is available. More broadly, because the model recovers physical parameters rather than opaque features, instrument or excitation changes with known physical effects could in principle be applied analytically to the learned parameters, a capability not available to black-box approaches. We see this as a promising direction and thank the reviewer for the suggestion.
We thank the reviewer again for the depth of the review and hope these clarifications and additional results address the concerns raised.
- Rating
- 5/6
- Confidence
- 2/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 4/4
- Originality
- 3/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper mainly works on problems with item intensive process of waiting for flouresence to bleach before recording the Raman spectrum, whereas this paper introduces a concept of utilising the short yet incomplete recordings of the bleaching process and argue that these recordings contain enough information to actually recover the underlying Raman signal. There are multiple contributions claimed by the author/s with their VAE-based framework. Authors conducted experiments on a downstream peak detection task ‘spectral reconstruction’, outperforming SOTA methods on multiple benchmarks and their newly collected real world dataset.
Strengths and weaknesses
Strengths: • The paper is easy to follow. • Authors introduced a new concept of LUMOS, modifying the VAE with physics-informed unsupervised mechanism. • Extensive ablation study as well comparison with other techniques. • A newly introduced dataset with 431 measure Raman bleaching time series. Weaknesses: • The core idea is highly influenced by some of the previous conceptual items with some minor modifications. • References are hard to trace and not very easy to follow and identify. • The comparisons and experimental analysis could be made more fair w.r.t the methodologies in place and observed. • Ablation studies could be more expensive, particularly around the architecture being followed is VAE, where it could benefit from more relevant diffusion models.
Questions
Questions: • Why authors only tested their method with one type of neural architecture? • Authors could have included more critical ablations? • What are some other evaluation metric from qualitative perspective that could be used for your as well as other datasets?
Limitations
yes
Final justification
I mismatched the contribution with another criteria.
Therefore, I've modified my score considering the response about the newly designed approach which is of course based on some existing methods yet the training strategy is convincing and results along with new dataset.
I agree with the author that within this approach, your contribution is good enough to be published, so improving the score.
References contain some differnet numbers.
Formatting concerns
references are strange.
2 comments
Rebuttal
We thank the reviewer for their insightful feedback. We will address all points below.
Novelty: 'Highly influenced by previous conceptual items with minor modifications.'
It is true that our approach is based on established insights into the mechanisms of data generation in spectroscopy. However, to the best of our knowledge, we are the first to combine these insights in an unsupervised ML model. Furthermore, we would like to point out that our manuscript was submitted under the 'use-inspired' (https://neurips.cc/Conferences/2026/ReviewerGuidelines) category, which calls for submissions based on 'a novel combination of existing methods to match the characteristics of the data'.
Evaluation and Ablation:
The originality of the problem means that, as of now, there are no established datasets, evaluation practices, or baseline methods designed to work on partially observed bleaching time series. We believe we did our best to evaluate our method fairly, comparing against multiple versions of established baseline-removal methods, and even fine-tuning the noise-removal hyperparameters on the test set to give the strongest possible baseline.
While we have ablated the main hyperparameters (sequence length, noise severity, regularization), we recognize there are further ablations worth reporting, and have run the following experiments.
We retrained our model on the cancer dataset with K = 4, 8, 16, and 32 learnable fluorophores, achieving Pearson correlations on the estimated Raman spectrum of 0.73, 0.91, 0.92, and 0.92, respectively. This indicates that the method reacts robustly to allowing more learnable fluorophores than are present, and is not sensitive to K above a threshold.
We additionally optimized the parameters per sample under the same physics-based forward model, instead of training a VAE. LUMOS achieves a Pearson correlation of 0.91, whereas direct optimization yields only 0.49. Providing the true sample fluorophores raises this to 0.68, and only when we additionally provide the true decay rates and abundances does direct fitting reach 0.91. We note that this final case is highly unrealistic, as it effectively supplies the answer and leaves only the residual Raman to recover. The fact that LUMOS, given only the short time series, competes with a fit that was supplied all fluorescence-related parameters demonstrates the power of our approach.
Alternative architectures:
While we agree that exploring other types of generative models (e.g., diffusion models) could be worthwhile, we would like to highlight that our model allows for unsupervised training while simultaneously learning the parameters of our forward model (e.g., the noise model). VAEs offer a clear avenue for training in this setting. On the other hand, little work exists on training diffusion models in an unsupervised fashion [1], and it is far from obvious how the forward model could be trained simultaneously. However, we do see this as a promising direction for future work.
Daras, Giannis, et al. "Ambient diffusion: Learning clean distributions from corrupted data." Advances in Neural Information Processing Systems 36 (2023): 288-313.
'References hard to trace':
We would appreciate it if the reviewer could kindly provide some examples of where they found the references difficult to follow, so that we can make amendments to the camera-ready version of the paper.
We thank the reviewer again for the depth of the review and hope these clarifications and additional results address the concerns raised.
Unsupervised Physics Informed Decomposition of Incomplete Time-Resolved Spectroscopy
I mismatched the contribution with another criteria.
Therefore, I've modified my score.
I agree with the author that within this approach, your contribution is good enough to be published, so improving the score.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Rebuttal
We thank the reviewer for their insightful feedback and will address the points below.
Novelty
We appreciate the reviewer's scrutiny here and would like to clarify what we consider to be the primary contribution of our work. We would first note the use-inspired track's framing of originality, which states that originality "need not mean wholly novel methods" and may consist of "a novel combination of existing methods to match the characteristics of the data, or a novel way of framing a stereotypical ML problem due to the particular needs of the use case." We believe LUMOS meets this criterion on several fronts. The problem itself is new: to our knowledge, no prior work addresses recovery of Raman spectra from short, incomplete photobleaching sequences, and the data type this requires did not previously exist, which is why we introduce it. The central insight, that an incomplete, unbleached decay sequence already contains sufficient information to separate constant Raman signals from decaying fluorescence, without waiting for complete bleaching is, we believe, new.
Importantly, we have now run additional experiments to probe how much our forward model itself, or its combination with a trained VAE contribute to overall performance. As such, we directly optimized parameters for each sample in the cancer dataset, instead of training a VAE. While VAE-based LUMOS achieves a Pearson correlation of 0.93 for the predicted Raman spectrum, the direct optimization yields a score of 0.49; and 0.68 when providing the true sample fluorophores. Only when we additionally provide the true decay rates and abundances for each sample did the direct fitting achieve a similar performance as LUMOS (0.91). Note that this latter case is highly unrealistic and effectively already removes the baseline, leaving the trivial task of fitting the Raman residual.
While LUMOS’ VAE-based architecture can learn a prior distribution of which patterns and correlations are likely to occur in the data by combining information from the whole training set, the non-amortized fitting does not have this benefit and has to separately process each sample, resulting in inferior results.
Evaluation bias and robustness to model mismatch
‘The synthetic data generation pipeline appears to mirror LUMOS’s internal generative assumptions (exponential decay, specific fluorophore mixtures, Voigt peaks, and Poisson-Gaussian noise)’
It is true that we use the established model (TODO CITE PAPER) of exponentially decaying fluorophores in our VAE and simulation pipeline. However, this is not the case with respect to the Raman spectra themselves. While our VAE assumes a combination of Voigt profiles, our simulated data uses real spectra from various sources without assuming a mixture of Voigt shapes. Regarding the noise model, we use Poisson Gaussian noise in our simulation, but a Gaussian approximation with variable linear variance in our VEA. Again, Possion-Gaussian noise and this approximation are well established model [ ZLFW23 ]. Importantly, in order to avoid an incorrect positive evaluation based on matching unrealistic models, we present a novel non-simulated directly measured Raman bleaching dataset, which will be published upon acceptance of the paper. We would like to highlight that our model outperforms its competitors in both, the real and simulated datasets. The strongest evidence against "the gains merely reflect matched assumptions" is that they persist on data we did not generate. We welcome any suggestions as to which aspect of our forward model could be more realistic and how it could be further improved to avoid spurious results.
Limitations of real-world validation
We agree with the reviewer, and this is the most important caveat in the evaluation. There is no true physical Raman ground truth for live cells - the residual fluorescence in incomplete bleaching is intrinsic to the problem addressed by the paper - so the late-frame average is a necessary estimated reference rather than a physical one. We would add that baseline subtraction and Savitzky–Golay smoothing of weak Raman signals is standard practice, so the estimate is constructed in the conventional way rather than tuned to favour our method; if anything, constructing the reference with the same SavGol and baseline-subtraction steps that the classical methods themselves use may favour those baselines rather than LUMOS. On dataset size, we agree it is modest; strong performance in this low-data regime is itself part of the contribution: that an unsupervised model can compete with industry-standard and state-of-the-art supervised methods on so few samples is unusual, and would not be possible without the physical priors.
The "unsupervised" framing
We take this point and would like to make a clear distinction. LUMOS uses no labels and never observes a clean Raman spectrum; its only supervision signal is the physical contrast that the Raman component is constant while fluorescence decays according to a known process. In the standard sense, learning without labelled targets is unsupervised learning. The reviewer is correct that the model carries strong physical priors, but we would distinguish inductive bias from supervision: strong priors narrow the hypothesis space rather than providing labels. We regard this as a strength rather than a weakness, since it is what facilitates efficient and transparent training from few examples. We would additionally add that these priors are not per-dataset tuned - the same configuration and hyperparameters are used across all datasets without adjustment.
Finally, on the reviewer's related point that we do not demonstrate a scenario where the unsupervised approach succeeds and supervised methods fail: on the real dataset, LUMOS outperforms both supervised RADAR variants (pretrained and finetuned) on PSNR, SI-PSNR, Pearson, SAM, AUPRC and Max F1, despite using no labels.
We thank the reviewer again for the depth of the review and hope these clarifications and additional results address the concerns raised
Questions:
Q1. Can authors clarify the primary methodological novelty beyond combining existing methods?
The primary methodological novelty is addressed in our response to weakness 1. In brief: LUMOS is, to our knowledge, the first unsupervised model to recover Raman spectra from short, incomplete photobleaching sequences, a problem and data type that did not previously exist, and our per-sample optimisation experiment shows the physics-plus-amortisation combination resolves a decomposition degeneracy that neither component achieves alone.
Q2 & Q3. How sensitive is LUMOS to violations of the model assumptions?
Sensitivity to assumption violations and to distribution shift are closely related, and we address both in our response to weakness 2. In brief: the real dataset is generated by an unknown physical process that departs from the model's idealised assumptions, and LUMOS's strong performance there is evidence of robustness to such violations. As we note in weakness 2, a controlled model-mismatch study would strengthen this further, and we see it as a clear next step.
We thank the reviewer again for the depth of the review and hope these clarifications and additional results address the concerns raised.