SpikeSSL: A Universal Spike Inference Framework with Dynamics-Informed State-Space Layers
Chenghao Yue, Siming Xing, shuran liu, Angran Li, Yuanlong Zhang
NeurIPS 2026
Abstract. Two-photon calcium imaging is a standard tool for recording large neural populations in vivo, yet inferring spikes accurately across the growing diversity of calcium indicators remains an open problem. Existing supervised methods achieve reasonable in-domain accuracy but generalize poorly to unseen indicators, because different indicators induce distinct fluorescence kinetics and signal statistics while existing architectures remain relatively simple generic temporal regressors without dynamics-matched inductive bias. We propose SpikeSSL, a universal spike inference framework whose temporal backbone is a bank of bidirectional IIR state-space layers broadly motivated by calcium dynamics. A multi-modal conditioning encoder maps indicator identity, sampling rate, and trace-level signal statistics into a global conditioning vector that modulates the backbone via Adaptive Layer Normalization, while a heteroscedastic variance head provides calibrated per-frame uncertainty. On a benchmark with five fixed evaluation splits built from 33 public ground-truth datasets, SpikeSSL achieves state-of-the-art performance in both in-domain and zero-shot leave-one-indicator-out settings. We also develop a biophysical simulation pipeline capable of generating paired fluorescence-spike traces with systematically varied kinetic parameters, spike statistics, response nonlinearities, baseline drift, and noise. Using this pipeline, we synthesize approximately 11{,}000 simulated traces. Augmenting training with these data effectively closes the cross-indicator domain gap and improves zero-shot generalization. Code is publicly available at https://github.com/detimage123/SpikeSSL.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:44 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
Reviewers lean positive overall (accept to borderline reject), agreeing SpikeSSL addresses a practically important problem — generalizing spike inference across calcium indicators — with a well-motivated architecture, though several question how "universal" and "zero-shot" the method's claims really are.
- Multiple reviewers want the zero-shot claim stress-tested: one asks for comparison against indicator-specific oracle models to clarify whether SpikeSSL can replace specialized training or is mainly valuable when target data is unavailable, while another notes the AdaLN conditioning uses target-domain trace statistics at test time, which may make the setting closer to few-shot adaptation than true zero-shot generalization.
- Reviewers flagged incomplete statistical rigor and mixed evidence for individual components — no standard deviations or significance tests in the main results or ablation tables, and one reviewer noted the simulation-augmentation pipeline doesn't uniformly help (it slightly hurts on the Other-RCaMP split), warranting more analysis of when it helps or hurts.
- The most critical reviewer raised practical limitations (bidirectional layers preclude real-time use, a fixed 0.5 gating threshold lacking sensitivity analysis, and susceptibility of global statistics to motion artifacts/baseline drift) and requested an ablation removing indicator ID to isolate the true source of generalization.
Final justification
The authors provided substantial rebuttals to the primary reviewer concerns, and the paper will be stronger as a result. The two most substantive reviewers both recommended acceptance, and the reviewer with the least substantive comments did not engage with the rebuttal. I think this is a solid paper and I recommend acceptance.
Read meta-review
Meta-review
Reviewers lean positive overall (accept to borderline reject), agreeing SpikeSSL addresses a practically important problem — generalizing spike inference across calcium indicators — with a well-motivated architecture, though several question how "universal" and "zero-shot" the method's claims really are.
- Multiple reviewers want the zero-shot claim stress-tested: one asks for comparison against indicator-specific oracle models to clarify whether SpikeSSL can replace specialized training or is mainly valuable when target data is unavailable, while another notes the AdaLN conditioning uses target-domain trace statistics at test time, which may make the setting closer to few-shot adaptation than true zero-shot generalization.
- Reviewers flagged incomplete statistical rigor and mixed evidence for individual components — no standard deviations or significance tests in the main results or ablation tables, and one reviewer noted the simulation-augmentation pipeline doesn't uniformly help (it slightly hurts on the Other-RCaMP split), warranting more analysis of when it helps or hurts.
- The most critical reviewer raised practical limitations (bidirectional layers preclude real-time use, a fixed 0.5 gating threshold lacking sensitivity analysis, and susceptibility of global statistics to motion artifacts/baseline drift) and requested an ablation removing indicator ID to isolate the true source of generalization.
Final justification
The authors provided substantial rebuttals to the primary reviewer concerns, and the paper will be stronger as a result. The two most substantive reviewers both recommended acceptance, and the reviewer with the least substantive comments did not engage with the rebuttal. I think this is a solid paper and I recommend acceptance.
- Rating
- 3/6
- Confidence
- 3/5
- Quality
- 2/4
- Clarity
- 2/4
- Significance
- 2/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes a universal spike inference framework, SpikeSSL, that infers neuronal spike rates from two-photon calcium imaging data across different, unseen calcium indicators. It combines dynamics knowledge with bidirectional state-space layers to extract temporal features. The paper also creates a biophysical simulation pipeline for data augmentation. Experimental results show that the method achieves SOTA performance.
Strengths and weaknesses
Strengths:
- Combining dynamics knowledge with state-space layers gives the framework strong zero-shot generalization capabilities.
- The biophysical simulation pipeline provides high-quality data augmentation, helping the framework achieve state-of-the-art performance.
- The framework achieves SOTA performance across multiple diverse datasets.
Weaknesses:
- The bidirectional nature of the state-space layers inherently relies on future context, rendering the proposed method unsuitable for real-time inference applications.
- The rigid choice of a 0.5 gating threshold tends to inadvertently suppress genuine weak signals, particularly in low signal-to-noise ratio (SNR) regimes.
- The global statistics are highly特 susceptible to distortion induced by localized motion artifacts or baseline drifts.
Questions
Q1: In the ablation study, the authors do not evaluate the performance without the indicator ID. Incorporating this specific baseline is highly desirable, as it would conclusively demonstrate the true source of the model's generalization capability.
Q2: The choice of a fixed 0.5 threshold for noise filtering during inference lacks sufficient justification. To ensure the reliability of the core claims, the authors should include a threshold sensitivity study (e.g., varying from 0.3 to 0.7) to verify the model’s stability under different filtering regimes.
Q3: In Figure 2, the LN layer is erroneously drawn on the residual path, which contradicts the architectural diagram provided in the Appendix.
Limitations
No.
Formatting concerns
No.
3 comments
Dear Reviewer,
Thank you again for highlighting these practical concerns. We added the indicator-ID ablation, a gate-threshold sensitivity study, clarification of the LayerNorm placement, and stress tests under baseline drift and motion artifacts. We also clarified that SpikeSSL targets offline inference and remains noncausal within each bounded window. We would be grateful to know whether these results address your main concerns.
Best regards, The authors
Dear Reviewer,
Thank you again for carefully identifying these important practical concerns and for giving us the opportunity to strengthen the work. With the author-reviewer discussion period nearing its conclusion, we would be sincerely grateful if you could briefly indicate whether the added indicator-ID ablation, threshold-sensitivity analysis, artifact robustness tests, and clarification of the noncausal offline setting have adequately addressed your concerns. We fully appreciate the time required for reviewing, and any further feedback from you would be extremely helpful to us. We remain ready to clarify any unresolved issue before the discussion closes.
Best regards, The authors
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper presents SpikeSSL, a spike inference framework for calcium imaging trace that aims to generalize across calcium indicators. The method uses bidirectional IIR state-space layers motivated by first-order calcium dynamics, together with conditioning based on indicator identity, sampling rate, and trace-level statistics to modulate the IIR backbone. The overall goal is to infer the underlying spike-rate signal from fluorescence traces in a way that is more robust across different indicators and experimental conditions. The authors also construct a simulation pipeline to generate synthetic data with diverse statistics. These simulated traces are then used as augmentation during training. The results suggest that this augmentation improves SpikeSSL and also helps other learned baselines compared to training without synthetic data. The method is evaluated on a datasets spanning multiple calcium indicators, using both in-domain and held-out evaluations. SpikeSSL outperforms existing baselines such as OASIS, and CASCADE.
Strengths and weaknesses
The paper addresses an important and practically relevant problem. Generalizing spike inference across calcium indicators is difficult and useful, especially because paired electrophysiology/calcium ground truth is expensive to collect. The model design is coherent with the problem at hand: the IIR layers are well matched to calcium decay dynamics, the conditioning mechanism is reasonable, and the simulation augmentation is motivated by the fact that real-wrold labels for this task are limited. The evaluation compares against standard baselines and shows improvements in both in-domain and held-out settings. The ablations also suggest that different components of the model are useful. Overall, the evaluation setup and reported metrics are sensible.
However, I have several concerns, listed below.
-
The scope of the zero-shot setting seems limited, and some technical details remain unclear for realistic zero-shot deployment. SpikeSSL conditions through AdaLN on indicator identity, sampling rate, and trace-level statistics. If these statistics require many samples from the target experiment, then although no model update is performed, the method still uses target-domain fluorescence to estimate the statistics of the held-out setting. This weakens the zero-shot claim and makes it closer to a few-shot target-domain adaptation and should be clarified/discussed. In particular, the authors should explain whether these statistics are computed from the whole target dataset or only few trace samples from target dataset, and how performance changes when only limited target-domain fluorescence is available.
-
Relatedly, the paper’s evaluation setting is label-free with respect to the held-out target recordings, but it is not a fully unseen sensor benchmark or does not strictly leave one lab out for evaluation. The splits are held-out distribution shifts within the same setup, and some involve closely related indicator variants. Therefore, the results support transfer across selected held-out conditions, but they do not fully establish "universal" zero-shot generalization across labs or unseen indicators.
-
The scaling discussion is limited to model-size scaling and leaves the data-scaling question open. The paper states that further scaling SpikeSSL does not yield additional gains. However, this does not answer whether performance is limited by data diversity, synthetic-data quality, or model capacity or design. It would be helpful to report data-scaling curves, such as performance versus the amount of real data or synthetic data, or the number of indicators included during training. This would clarify whether the method has saturated because of data limitations and what the expected upper limit might be as more paired calcium/electrophysiology data become available in the future.
-
Statistical significance is not sufficiently reported. The main result tables give point estimates, but I did not see standard deviations across random seeds or significance tests for the method comparisons. This is especially relevant for Table 4, where the ablations are reported as single mean-correlation values with no standard deviations, even though some component gains are modest.
-
The role of the simulator need more evidence or discussion. Table 3 shows that simulation improves the mean correlation, but it does not improve every split. For example, the Other-RCaMP split slightly decreases compared with SpikeSSL without simulation. This suggests that the simulator is not uniformly beneficial. More analysis of when synthetic data helps or hurts, and discussion scenarios where it would hurt, would strengthen the paper.
Questions
- How much target-domain data is needed to compute the trace statistics used for AdaLN conditioning?
- At test time, is the held-out indicator encoded as an unknown indicator, as its true indicator ID, or through another metadata representation? If the unknown-indicator embedding is used, how is this embedding trained?
- The paper defines the combined form of the structural penalty in Equation 10 and describes the three components in words. However, I could not find explicit mathematical definitions for , , and in the main text or appendix. For reproducibility, the deatils and exact formulas should be reported.
Limitations
Yes
Final justification
Most of my concerns have been addressed, and I will keep my positive score while raising my confidence to 4.
The zero-shot setup is now much clearer: LOIO uses the unknown indicator ID, trace statistics are computed only from the current unlabeled input window, and there is no target domain update. This resolves my main concern that the setup might be closer to few-shot adaptation.
The added clarifications of loss formulas, results for scaling of data, seeded results for the main experiments and ablations, and analysis of when simulation helps also strengthen the paper.
Formatting concerns
--
5 comments
Rebuttal
Q1. How much target-domain data is used for trace statistics?
Thank you. The seven statistics are computed from the current input window, so LOIO uses one unlabeled window with no target-domain pool, labels, or update. This is per-window conditioning, not few-shot adaptation. Pooling 5, 20, or all windows does not improve correlation, showing that performance is independent of target-domain data volume.
| Mean Corr. | Per-window | Pool 5 windows | Pool 20 windows | Pool all windows |
|---|---|---|---|---|
| LOIO | 0.654 | 0.649 | 0.650 | 0.650 |
Q2. Test-time encoding of a held-out indicator
Thank you. LOIO always uses the reserved unknown code (ID=0), never the dye label. Because ID=0 is neither used nor optimized during training, it carries no target-domain information, and inference relies on sampling rate, window statistics, and the trace. Removing the ID branch changes LOIO correlation only from 0.654 to 0.647, versus 0.741 to 0.703 in-domain, confirming that ID mainly benefits observed domains. Split-wise results and the shuffled-ID control appear in our response to Reviewer tRGu, Q4.
Q3. Explicit definitions for Eq. (10)
Thank you. Let be the valid-frame mask and . All sums are over valid frames. The overestimation term is .
For , let be its size and be the Huber loss. The peak term is .
The bias term is .
The structural term is .
We use , , , , and . We will add these equations to the appendix.
Q4. Scope of “universal” zero-shot generalization
We thank the reviewer for inviting us to clarify this point. Our corpus aggregates ground-truth recordings from many labs, sensors, species, regions, cell types, and protocols, not one setup (Supplementary Table 6). LOIO excludes every recording of the held-out family and performs no target-domain update. Real indicators are not deterministic kernels. Traces vary across indicators and repeated recordings. Figure 1 in the main paper shows this heterogeneity. We therefore quantify isolated-spike rise time, decay time, and SNR in the public recordings compiled by CASCADE.
| Indicator family | n | Rise μ±σ | Decay μ±σ | SNR μ±σ |
|---|---|---|---|---|
| Cal-520 | 6 | 0.086±0.085 | 0.253±0.094 | 5.533±2.295 |
| GCaMP5k | 36 | 0.079±0.095 | 0.073±0.058 | 3.934±0.904 |
| GCaMP6f | 907 | 0.061±0.071 | 0.119±0.120 | 5.570±4.358 |
| GCaMP6s | 436 | 0.104±0.095 | 0.177±0.173 | 5.713±3.011 |
| GCaMP6s spinal | 180 | 0.112±0.164 | 0.155±0.199 | 5.210±2.906 |
| GCaMP7f | 57 | 0.030±0.025 | 0.070±0.058 | 6.125±4.398 |
| GCaMP8 variants | 2,967 | 0.018±0.020 | 0.083±0.060 | 6.417±4.017 |
| Interneurons mixed | 102 | 0.037±0.056 | 0.050±0.044 | 3.886±0.936 |
| OGB-1 | 330 | 0.094±0.073 | 0.193±0.155 | 7.141±9.075 |
| R-CaMP | 260 | 0.082±0.069 | 0.235±0.201 | 10.831±11.666 |
| Unknown | 619 | 0.096±0.122 | 0.138±0.143 | 5.689±4.283 |
| XCaMPgf | 37 | 0.028±0.031 | 0.060±0.044 | 4.511±2.445 |
| jGECO1a | 96 | 0.066±0.056 | 0.126±0.092 | 6.110±3.671 |
| jRCaMP1a | 56 | 0.146±0.166 | 0.261±0.198 | 11.627±26.422 |
Rise-time standard deviation exceeds the mean for GCaMP6f, GCaMP8 variants, and XCaMPgf, showing substantial within-family heterogeneity. Across families, mean decay ranges from 0.050 s for mixed interneurons to 0.261 s for jRCaMP1a, while mean SNR ranges from 3.886 to 11.627 with markedly different dispersions. These event-level summaries are distinct from the baseline-aware exponential reported separately. Together, the within-family dispersion and cross-family shifts in rise, decay, and SNR confirm a substantial domain gap. Here, “universal” means one model that transfers across this diverse multi-laboratory benchmark without target labels or retraining. We therefore believe that “universal” is not an overclaim.
Q5. Data scaling
Thank you. We vary real data, synthetic data, and indicator coverage across five LOIO splits with fixed evaluation.
| Real-recording fraction | 25% | 50% | 75% | 100% |
|---|---|---|---|---|
| Corr. | 0.564 | 0.614 | 0.637 | 0.654 |
| Error | 1.791 | 1.534 | 1.133 | 1.123 |
| Absolute bias | 1.187 | 1.081 | 0.583 | 0.588 |
| Synthetic-data fraction | 0% | 25% | 50% | 75% | 100% |
|---|---|---|---|---|---|
| Corr. | 0.654 | 0.667 | 0.679 | 0.692 | 0.704 |
| Error | 1.123 | 1.118 | 1.113 | 1.108 | 1.103 |
| Absolute bias | 0.588 | 0.564 | 0.539 | 0.514 | 0.490 |
| Indicator families | 4 | 8 | 13 |
|---|---|---|---|
| Corr. | 0.543 | 0.583 | 0.654 |
| Error | 1.140 | 1.204 | 1.123 |
| Absolute bias | 0.871 | 0.811 | 0.588 |
More real data, more synthetic data, and broader indicator coverage improve mean correlation. We therefore conclude that data quantity is the primary limitation.
Q6. Variability, significance, and ablations
We thank the reviewer for pressing on statistical rigor. Across seeds {42, 2719, 8888, 1337, 2025}, LOIO is and in-domain is , within 0.006 and 0.002 of seed 42 (0.654 and 0.741). This supports robustness. Bias denotes mean absolute bias, and both tables will enter the appendix.
Five-seed LOIO results
| Split | Corr. | Error | Signed Bias |
|---|---|---|---|
| V1-OGB | 0.666 ± 0.030 | 1.096 ± 0.513 | −0.309 ± 0.574 |
| V1-GCaMP6s | 0.507 ± 0.022 | 0.951 ± 0.008 | −0.780 ± 0.069 |
| V1-GCaMP8 | 0.864 ± 0.013 | 0.531 ± 0.015 | −0.054 ± 0.213 |
| Other-RCaMP | 0.724 ± 0.013 | 1.141 ± 0.157 | 0.445 ± 0.267 |
| SC-GCaMP6s | 0.539 ± 0.018 | 0.889 ± 0.046 | −0.840 ± 0.082 |
| Mean | 0.660 ± 0.016 | 0.922 ± 0.116 | 0.486±0.074 |
Five-seed in-domain results
| Split | Corr. | Error | Signed Bias |
|---|---|---|---|
| V1-OGB | 0.729 ± 0.017 | 0.875 ± 0.062 | −0.131 ± 0.180 |
| V1-GCaMP6s | 0.575 ± 0.009 | 0.948 ± 0.005 | −0.779 ± 0.031 |
| V1-GCaMP8 | 0.917 ± 0.005 | 0.487 ± 0.044 | 0.036 ± 0.059 |
| Other-RCaMP | 0.748 ± 0.019 | 1.025 ± 0.137 | 0.149 ± 0.130 |
| SC-GCaMP6s | 0.728 ± 0.009 | 0.825 ± 0.036 | −0.784 ± 0.050 |
| Mean | 0.739 ± 0.004 | 0.832 ± 0.021 | 0.376±0.069 |
We also report error and mean absolute bias for removal and cumulative build-up. All entries are mean±std across the same five seeds. The bidirectional IIR backbone, multi-modal conditioning, gate head, and variance head each contribute positively, so the model is not redundant.
Removal ablations under LOIO
| Variant | Mean Corr. | Mean Error | Mean absolute Bias |
|---|---|---|---|
| − AdaLN | 0.604±0.014 | 1.276±0.103 | 0.456±0.061 |
| − statistics | 0.626±0.012 | 1.213±0.091 | 0.556±0.073 |
| − bidirectional IIR | 0.597±0.016 | 1.377±0.120 | 0.719±0.086 |
| − variance head | 0.611±0.013 | 1.243±0.112 | 1.005±0.105 |
| − gate | 0.624±0.011 | 1.153±0.084 | 0.402±0.057 |
| Full SpikeSSL | 0.660±0.016 | 0.922±0.116 | 0.486±0.074 |
Cumulative build-up under LOIO
| Stage | Mean Corr. | Mean Error | Mean absolute Bias |
|---|---|---|---|
| 1D U-Net backbone | 0.481±0.022 | 1.173±0.101 | 0.788±0.088 |
| Transformer backbone | 0.484±0.020 | 1.197±0.104 | 0.618±0.074 |
| Bidirectional IIR backbone | 0.539±0.018 | 1.191±0.101 | 0.757±0.083 |
| + Indicator ID | 0.550±0.017 | 1.167±0.096 | 0.696±0.079 |
| + Sampling rate | 0.554±0.016 | 1.175±0.098 | 0.672±0.077 |
| + Signal statistics | 0.576±0.015 | 1.145±0.091 | 0.703±0.081 |
| + AdaLN | 0.594±0.014 | 1.153±0.087 | 0.696±0.076 |
| + Gate | 0.612±0.013 | 1.117±0.082 | 0.665±0.071 |
| + Variance head | 0.660±0.016 | 0.922±0.116 | 0.486±0.074 |
Q7. When simulation helps or hurts
We thank the reviewer for requesting a mechanism-level analysis. We repeated LOIO with simulation across five seeds and measured each target gap in the exact conditioning space of SpikeSSL. Each 188-frame window uses log sampling rate, standard deviation, skewness, excess kurtosis, and autocorrelation at lags 1, 3, 5, and 10. After robust scaling, we compute 512-projection sliced Wasserstein-1 distance. Each is the real-only gap minus the equal-sampled real-plus-simulation gap, so positive values indicate better alignment. AC averages the four autocorrelation terms, while shape averages standard deviation, skewness, and kurtosis.
| Split | No-sim Corr. | +Sim Corr. | Corr. | SWD | AC | shape | Kurt. |
|---|---|---|---|---|---|---|---|
| V1-OGB | 0.666 ± 0.030 | 0.704 ± 0.012 | +0.038 | +0.013 | −0.111 | +0.008 | −0.132 |
| V1-GCaMP6s | 0.507 ± 0.022 | 0.531 ± 0.008 | +0.024 | +0.065 | +0.197 | −0.031 | +0.094 |
| V1-GCaMP8 | 0.864 ± 0.013 | 0.914 ± 0.015 | +0.050 | −0.090 | −0.124 | −0.157 | −0.260 |
| Other-RCaMP | 0.724 ± 0.013 | 0.712 ± 0.009 | −0.012 | +0.018 | +0.110 | −0.051 | −0.180 |
| SC-GCaMP6s | 0.539 ± 0.018 | 0.677 ± 0.010 | +0.138 | +0.126 | +0.187 | +0.065 | +0.202 |
| Mean | 0.660 ± 0.016 | 0.708 ± 0.011 | +0.048 |
The results reveal two mechanisms. SC-GCaMP6s has the largest overall (+0.126), temporal (+0.187), and shape (+0.065) gap reductions and the largest correlation gain (+0.138), while V1-GCaMP6s benefits from better autocorrelation alignment (+0.197). Other-RCaMP exposes a diagnostic failure mode. Simulation improves its autocorrelation alignment (+0.110) but worsens shape (−0.051), especially kurtosis (−0.180), consistent with incomplete coverage of red-indicator nonlinear statistics. Its −0.012 correlation change remains within five-seed variation, indicating no reliable gain rather than harm. GCaMP8 improves despite a larger marginal SWD. Since Wasserstein distance is label agnostic, this is consistent with paired synthetic supervision regularizing the inverse mapping across broader dynamics. Thus, simulation helps through target-gap closure or dynamics diversity, but may cause negative transfer if mismatched synthetic or conditional dynamics are overweighted. Reweighting or rejecting simulated windows by target-relative statistics from unlabeled traces provides a direct mitigation. We will describe simulation as broadly beneficial with a diagnosable, non-uniform failure mode.
Dear Reviewer,
Thank you again for your detailed feedback. We clarified that the trace statistics are computed only from the current unlabeled input window, added the no-ID ablation, explicit loss definitions, data-scaling results, five-seed statistics, and further analysis of when simulation helps or does not help. We would appreciate knowing whether these additions resolve your main concerns.
Best regards, The authors
Dear Reviewer,
Thank you again for the considerable time and care you have devoted to evaluating our work. With the author-reviewer discussion period nearing its conclusion, we would be sincerely grateful if you could briefly let us know whether our additional clarifications and experiments have adequately addressed your main concerns regarding the zero-shot setting, statistical rigor, and simulation augmentation. We fully understand how demanding the reviewing period is, and any further guidance from you would be extremely valuable to us. We remain ready to clarify any unresolved point before the discussion closes.
Best regards, The authors
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 4/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The topic of this paper is the spike inference from calcium imaging data. The main gap/challenge in the field is that different calcium indicators can have different fluorescence dynamics, so a model trained on one indicator may not work well on another. SpikeSSL is proposed to address this problem. From my understanding, the model uses temporal layers inspired by calcium decay, and it also uses information such as the indicator identity, sampling rate, and simple statistics of the trace to condition its prediction.
The authors also generate simulated calcium traces to increase the diversity of training data. Experimentally, they compare SpikeSSL with OASIS, MLSpike, CASCADE, and on several public ground-truth datasets. The main empirical finding is that SpikeSSL performs better than these baselines in both the in-domain setting and the leave-one-indicator-out setting (LOIO), and that adding simulated data further improves generalization to held-out indicators.
Strengths and weaknesses
The motivation of the paper is good. Different calcium indicators are used across labs, brain regions, animal species, and experimental preparations, and their fluorescence dynamics can vary substantially. Therefore, a method that generalizes across indicators without requiring a separately optimized model for each new condition would be useful.
I think using state-space layers as a dynamics-informed backbone is a smart idea, and conditioning the model on indicator identity, sampling rate, and trace stats is also well motivated. The model’s performance on the proposed benchmark is strong, especially in the zero-shot LOIO setting.
Weakness:
The paper does not clearly establish what is gained over indicator-specific supervised models. The motivation suggests that a universal model can reduce the need to train separate models for each indicator. However, if enough ground-truth data are available for a particular indicator, users would presumably prefer the model that performs best on that indicator, even if it is not universal. Therefore, it is important to know whether SpikeSSL is mainly useful when target-indicator ground truth is unavailable, or whether it also remains competitive when indicator-specific training is possible.
The current experiments mostly compare SpikeSSL with other baselines in unified or zero-shot settings. I do not see a direct comparison against oracle models trained or fine-tuned specifically on the target indicator. If ground-truth data for indicator A are available, a specialized model may still outperform the universal model on A. Without this comparison, I think the paper supports the claim that SpikeSSL is strong for cross-indicator transfer, but not the stronger claim that it can replace indicator-specific optimization.
Relatedly, the paper should clarify the data regime in which the method is intended to be used. If no target-indicator data are available, the LOIO result is relevant. If a small amount of target data is available, it would be useful to see few-shot fine-tuning results. If abundant target data are available, the right comparison is against fully indicator-specific models. These are different practical settings, and the current paper does not clearly distinguish them.
The second point is that the current LOIO setting may mix several kinds of domain shift. The held-out groups appear to differ not only in indicator identity, but also in neuron type, brain region, brain stat, imaging condition and so on. It is hard to know from the current evidence whether the gain comes from better modeling of indicator kinetics specifically, or from more general robustness to dataset shift.
Finally, the “dynamics-informed” interpretation is plausible but not fully demonstrated. The IIR recurrence resembles decay, but I am not sure that the learned effective decay rates actually correlate with known indicator kinetics.
Questions
Can the authors compare SpikeSSL with indicator-specific oracle models? For example, for each target indicator, train or fine-tune a model using the target indicator’s training data and evaluate it on the corresponding test data. This would help clarify whether SpikeSSL can replace indicator-specific optimization, or whether its main value is in the setting where target-indicator ground truth is unavailable.
Can the authors clarify the intended data regime for this method? Is SpikeSSL mainly designed for the no-target-data setting, the few-target-data setting, or the abundant-target-data setting? If a small amount of target-indicator data is available, a few-shot fine-tuning experiment would be useful.
Can the authors further disentangle the LOIO result? The current held-out splits may mix indicator shift with brain region, brian state, and imagie condition. It would be helpful to know whether the performance gain remains when these factors are separated as much as possible. If this is not possible with the current dataset, I think this limitation should be stated more clearly.
Can the authors show whether the learned effective decay rates are related to known indicator kinetics? For example, do slow indicators lead to slower learned decay constants than fast indicators? This would help support the “dynamics-informed” interpretation. What happens if the indicator identity is intervened? This would help clarify whether the model is truly adapting to trace dynamics, or whether it mainly benefits from having the correct domain.
Limitations
The current main limitation is that the paper does not clearly show whether SpikeSSL is better than models trained specifically for one indicator. The LOIO setting may also mix indicator differences with other dataset differences.
Final justification
After considering the rebuttal and discussion, I will keep my score at 5. The indicator-specific and few-shot experiments address my main concern and clarify the practical value of SpikeSSL in the current limited-data setting. The mini-domain and learned-dynamics analyses also strengthen the paper. Some questions remain about the abundant-target-data setting, complete separation of domain shifts, and direct interpretation of the learned decay parameters. I view these as limitations rather than critical flaws.
Formatting concerns
No
4 comments
Rebuttal
Q1. Comparison to indicator-specific models
Thank you for this important question. We added a CASCADE-compatible per-indicator comparison across all 13 indicator families. Each row holds out one recording of that indicator and uses all remaining recordings of that indicator for specific-model training. The universal models are trained by pooling the training recordings from all 13 indicators. All four conditions use the same held-out recording in each row.
Pearson correlation (r)
| Indicator | CASCADE-spec | SpikeSSL-spec | CASCADE-univ | SpikeSSL-univ |
|---|---|---|---|---|
| OGB1 | 0.663 | 0.760 | 0.583 | 0.728 |
| Cal520 | 0.721 | 0.633 | 0.647 | 0.693 |
| GCaMP5k | 0.687 | 0.520 | 0.688 | 0.695 |
| GCaMP6f | 0.500 | 0.626 | 0.416 | 0.562 |
| GCaMP6s | 0.262 | 0.435 | 0.279 | 0.628 |
| GCaMP7f | 0.776 | 0.508 | 0.412 | 0.816 |
| GCaMP8f | 0.753 | 0.928 | 0.815 | 0.933 |
| GCaMP8m | 0.799 | 0.939 | 0.809 | 0.928 |
| GCaMP8s | 0.884 | 0.927 | 0.767 | 0.912 |
| R-CaMP | 0.309 | 0.555 | 0.644 | 0.691 |
| jRCaMP1a | 0.689 | 0.538 | 0.662 | 0.769 |
| jGECO1a | 0.736 | 0.613 | 0.672 | 0.790 |
| XCaMPgf | 0.797 | 0.537 | 0.446 | 0.833 |
| Mean Corr. | 0.660 | 0.655 | 0.603 | 0.768 |
The two specific models are nearly tied on average, but win on different indicators. SpikeSSL-specific is weaker than CASCADE-specific on some indicators, consistent with underfitting when the larger model receives only limited per-indicator data. On other indicators it is stronger, showing that it can learn the relevant dynamics when the data are sufficiently informative. This mixed result is expected in the low-data specific setting.
CASCADE-specific is stronger than CASCADE-universal overall, 0.660 versus 0.603, and on eight of 13 indicators, indicating a limitation when its architecture pools heterogeneous recordings. SpikeSSL instead benefits from pooling, which raises mean correlation from 0.655 to 0.768, gives the best result on eight of 13 indicators, and exceeds SpikeSSL-specific on nine. The parameter-matched main-paper comparisons show that this gain is not explained by model size. These results also clarify practical use. SpikeSSL-universal is used directly without labels, fine-tuned once at least five target neurons are labeled, and compared against indicator-specific training when labels are abundant. It leads our 13-family comparison overall, 0.768 versus 0.655.
Q2. Few-shot fine-tuning
Thank you for asking about the low-data regime. For each split, we first set aside 20 target-domain neurons as a support pool and evaluate on all remaining traces. For , we fine-tune from the universal LOIO pretrained weights using labeled neurons from this pool.
Pearson correlation (r)
| k | V1-OGB | V1-GCaMP6s | V1-GCaMP8 | Other-RCaMP | SC-GCaMP6s | Mean Corr. |
|---|---|---|---|---|---|---|
| 0 | 0.622 | 0.466 | 0.843 | 0.696 | 0.493 | 0.624 |
| 1 | 0.488 | 0.324 | 0.766 | 0.649 | 0.606 | 0.567 |
| 3 | 0.509 | 0.389 | 0.888 | 0.683 | 0.545 | 0.603 |
| 5 | 0.521 | 0.412 | 0.895 | 0.718 | 0.648 | 0.639 |
| 10 | 0.621 | 0.459 | 0.862 | 0.721 | 0.714 | 0.675 |
| 20 | 0.707 | 0.548 | 0.892 | 0.725 | 0.722 | 0.719 |
At , mean is 0.567, below the zero-shot value of 0.624. Target-domain recordings are themselves diverse in morphology and kinetics, so fitting only a few support neurons cannot adapt to all remaining target-domain traces. Performance improves as grows. It first exceeds zero-shot at with mean and reaches 0.719 at .
Q3. Disentangle LOIO
Thank you for pointing out that LOIO mixes indicator identity with other dataset shifts. We constructed mini-domain splits that hold one indicator fixed and vary a single additional factor. The other shift types are excluded from each experiment’s data pool.
| Indicator | Shift varied | Train → Eval |
|---|---|---|
| GCaMP6f | Species | Mouse V1 (DS09–11, X-DS09/10) → Zebrafish (DS06–08) |
| GCaMP6f | Cell type | Mouse V1 excitatory + PV/SST/VIP interneurons → DS33 interneuron panel |
| GCaMP6s | Tissue | Brain cortex inhibitory V1 (DS41) → Spinal cord excitatory (DS40) |
Within each row, brain region, species, and cell class are held as consistent as the underlying public recordings allow for that shift. For example, the species split fixes GCaMP6f and imaging conditions but changes species and anatomical target. The cell-type split fixes mouse V1 and GCaMP6f but changes the labeled cell population. The tissue split fixes GCaMP6s kinetics but changes organ. SpikeSSL attains the highest correlation on all three splits and remains substantially better than every preceding method on the primary metric.
Mini-domain results. Each table reports Pearson correlation, normalized error, and signed bias. Higher correlation and lower error or absolute bias are better.
Species shift, GCaMP6f
| Method | Corr. | Error | Bias |
|---|---|---|---|
| OASIS | 0.191 | 0.982 | −0.945 |
| MLSpike | 0.085 | 1.130 | −0.706 |
| CASCADE | 0.540 | 1.304 | 0.539 |
| ENS2 | 0.476 | 1.266 | 0.229 |
| SpikeSSL | 0.636 | 0.952 | −0.442 |
Cell-type shift, GCaMP6f
| Method | Corr. | Error | Bias |
|---|---|---|---|
| OASIS | 0.266 | 0.985 | −0.974 |
| MLSpike | 0.098 | 1.015 | −0.897 |
| CASCADE | 0.574 | 0.977 | −0.144 |
| ENS2 | 0.584 | 0.898 | −0.680 |
| SpikeSSL | 0.673 | 0.931 | −0.798 |
Tissue shift, GCaMP6s
| Method | Corr. | Error | Bias |
|---|---|---|---|
| OASIS | 0.365 | 0.975 | −0.964 |
| MLSpike | 0.307 | 1.005 | −0.919 |
| CASCADE | 0.226 | 1.083 | −0.442 |
| ENS2 | 0.278 | 1.092 | −0.391 |
| SpikeSSL | 0.542 | 0.911 | −0.592 |
Q4. Learnable decay vs. kinetics and indicator ID intervention
Thank you for these two mechanistic questions.
Learnable decay vs. indicator kinetics. We report four complementary quantities. Ref. τ is the catalogue decay time. Measured τ is fitted from isolated real fluorescence responses at 30 Hz using a joint baseline and exponential fit, not model weights. ‖W_α‖ and ACF τ are extracted from a separate SpikeSSL model trained for each indicator family.
The conditioned IIR rate is a bank of channel-wise values, and the matrix maps the condition vector to its shift. We use the Frobenius norm ‖W_α‖ to measure how strongly conditioning moves the learned bank. Its magnitude is not a time constant and has no fixed proportional relation to τ. The norms differ markedly across indicators, showing indicator-dependent effects on the bank. Conversely, the three GCaMP8 variants have similar norms (5.35, 6.11, and 5.94), consistent with their similar fast kinetics. These differences and similarities show that the model learns indicator-specific dynamics. ACF τ is fitted from IIR-output autocorrelation. It is positively correlated with measured τ (Spearman ρ = 0.886, p = 5.6×10⁻⁵), although not in a strict one-to-one ratio. Together, the weight and output readouts show that SpikeSSL is informed by indicator dynamics rather than using a fixed shared kernel.
| Indicator | Ref. τ (ms) | ‖W_α‖ | Measured τ (data, ms) | ACF τ (ms) |
|---|---|---|---|---|
| GCaMP8f | 60 | 5.35 | 175 | 145 |
| GCaMP8s | 70 | 5.94 | 314 | 165 |
| GCaMP8m | 80 | 6.11 | 136 | 132 |
| GCaMP7f | 100 | 0.60 | 223 | 154 |
| XCaMPgf | 120 | 0.39 | 179 | 152 |
| GCaMP6f | 180 | 5.44 | 212 | 140 |
| Cal520 | 200 | 0.41 | 878 | 178 |
| GCaMP5k | 250 | 0.50 | 547 | 163 |
| R-CaMP | 280 | 0.25 | 535 | 171 |
| jRCaMP1a | 280 | 0.74 | 756 | 163 |
| jGECO1a | 300 | 0.81 | 572 | 162 |
| GCaMP6s | 600 | 4.64 | 912 | 192 |
| OGB1 | 750 | 2.59 | 854 | 191 |
Indicator ID intervention (LOIO and in-domain, Pearson r). The LOIO baseline uses the reserved ID=0. Removing the ID branch only reduces LOIO correlation from 0.654 to 0.647, so zero-shot transfer does not strongly rely on ID. In this setting, the model can still use the sampling rate, window statistics, and trace. In-domain training receives the correct ID. Shuffling it at inference then reduces correlation from 0.741 to 0.578, showing that an inconsistent ID substantially disrupts the model’s judgment. Removing the ID branch in-domain gives 0.703, showing that ID primarily captures observed domain-specific regularities.
| Setting | V1-OGB | V1-GCaMP6s | V1-GCaMP8 | Other-RCaMP | SC-GCaMP6s | Mean Corr. |
|---|---|---|---|---|---|---|
| LOIO baseline (ID=0) | 0.650 | 0.509 | 0.853 | 0.717 | 0.542 | 0.654 |
| LOIO without ID branch | 0.646 | 0.500 | 0.849 | 0.708 | 0.532 | 0.647 |
| In-domain full model | 0.743 | 0.579 | 0.915 | 0.731 | 0.736 | 0.741 |
| In-domain shuffled ID | 0.587 | 0.457 | 0.791 | 0.619 | 0.437 | 0.578 |
| In-domain without ID branch | 0.700 | 0.546 | 0.881 | 0.694 | 0.694 | 0.703 |
Dear Reviewer,
Thank you again for your constructive review. Following your suggestions, we added indicator-specific comparisons across 13 indicator families, few-shot adaptation results, controlled mini-domain experiments, and analyses relating the learned dynamics to indicator kinetics. We would be grateful to know whether these additions address your main concerns, and we are happy to clarify any remaining questions.
Best regards, The authors
Thank you for the detailed rebuttal and the additional experiments. The indicator-specific comparison directly addresses my main concern. From my understanding, under the current data setting, the universal SpikeSSL performs better on average than both SpikeSSL-specific and CASCADE-specific models. The few-shot results also make the practical use case clearer. When very little target data are available, zero-shot inference seems to work better, while fine-tuning becomes helpful when more labeled neurons are available.
For my second concern, I think the mini-domain experiments are helpful. They show that SpikeSSL also performs well under species, cell-type, and tissue shifts. However, some of these splits still change more than one factor at the same time. Therefore, I think these results mainly support the general robustness of the model to dataset shift, rather than fully separating the effect of indicator kinetics.
The additional analysis of the learned dynamics is also helpful. The correlation between the IIR-output timescale and the measured indicator kinetics, together with the indicator-ID intervention, gives stronger support to the dynamics-informed interpretation. However, the relationship between the learned decay parameters and the actual biophysical time constants is still somewhat indirect.
Overall, the rebuttal addresses most of my concerns and increases my confidence in the paper. I will keep my rating at 5. I think this is a strong paper for this specific problem. The remaining questions about the abundant-target-data setting, mixed domain shifts, and the interpretation of the learned dynamics are not serious enough to change my accept decision, but they also make it difficult for me to increase the rating to 6. I do not think more rebuttal experiments are necessary, but I encourage the authors to clarify these points in the revised paper.
Dear Reviewer,
Thank you very much for your thoughtful follow-up and positive assessment. We greatly appreciate your careful consideration of the additional experiments and clarifications, and we will incorporate the remaining points regarding the abundant-data setting, mixed domain shifts, and interpretation of the learned dynamics into the revised manuscript.
Best regards,
The authors
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Rebuttal
Q1. Ablation without indicator ID
We thank the reviewer for requesting this decisive control. In LOIO, SpikeSSL is given an unknown indicator code (ID=0), never the held-out dye label. We trained and evaluated a version without the discrete-ID branch. Mean correlation decreases only slightly from 0.654 to 0.647. Thus, cross-indicator generalization does not depend strongly on indicator ID. Sampling rate and the seven statistics computed from the input window provide complementary metadata for the conditioned dynamics.
ID has a larger role in the in-domain setting, where it is observed and can capture domain-specific regularities. Mean correlation decreases from 0.741 to 0.703, a drop of 3.8 points.
Pearson correlation (r)
Q2. Gate-threshold sensitivity
We appreciate this important robustness check. We swept the inference threshold τ from 0.2 to 0.8 while keeping the trained model fixed. The default τ=0.5 gives the highest mean correlation at 0.654. Mean normalized error is lowest at τ=0.6. Mean absolute bias decreases through τ=0.7 as the gate becomes more conservative. Correlation is the most valuable metric for this task, so we use the correlation-optimal threshold of 0.5.
Correlation r
Normalized error
Normalized bias
Q3. Figure 2 LayerNorm placement
Thank you for raising this potential ambiguity. In both Figure 2 and Supplementary Figure 8(a), AdaLN is applied within the IIR branch before the residual addition. The two diagrams are therefore consistent. We apologize that the current drawing can be read differently and will make the labels and caption clearer.
Q4. Bidirectional layers and real-time inference
We appreciate this practical concern. Spike inference is predominantly an offline analysis task, and our benchmarks follow that setting. We agree that SpikeSSL is not a causal frame-by-frame filter because the bidirectional IIR block uses bounded future context within each window. However, inference uses sliding windows rather than whole-recording batches, so the model never needs an entire recording in memory. On an A100, a single-window forward pass is about 29 times faster than 30 Hz frame arrival. Overlapping windows can therefore keep pace with acquisition in many laboratory settings, although the method remains noncausal within a window.
Q5. Motion artifacts and baseline drift
We thank the reviewer for highlighting this failure mode. Our statistics are computed per window rather than over a whole trial, but this does not make SpikeSSL invariant to artifacts. On perturbed LOIO traces, drift is the dominant degradation. Motion alone is milder, and combined drift and motion also reduce performance. We will add this limitation and recommend standard motion correction and baseline detrending before inference.
Pearson correlation (r)