Selective Disk Bispectrum: A Complete and Rotation Invariant Image Descriptor
Adele Myers, Nina Miolane
NeurIPS 2026
TL;DR. We propose the selective disk bispectrum, an analytic descriptor which retains all information about an image while being invariant to planar rotation.
Abstract. The classical bispectrum is a signal representation with two fundamental properties desirable for machine learning. First, it is invariant to translation of the signal, and second the signal can be reconstructed (inverted) from its bispectrum coefficients, up to a translation. These properties, along with its ability to capture higher-order frequency correlations, have made the bispectrum a fixture for signal processing across science and engineering. For image processing, the relevant symmetry is rotation, and the disk bispectrum has been proposed for this domain. However, its size and computation time grow almost cubically with the number of basis functions, making its tractability difficult on downstream tasks. Furthermore, no inversion or completeness proof had previously been proposed. We introduce the \emph{Selective Disk Bispectrum} (SDB), a structured subset of disk bispectrum coefficients whose size grows linearly with the number of basis functions. We derive an explicit inversion algorithm proving that the SDB is complete, since an image can be reconstructed, up to a rotation, from its SDB coefficients alone. We verify the inversion numerically and demonstrate the SDB's practical benefits for (i) classification and (ii) multi-reference alignment on translated and noisy MNIST, FashionMNIST, and cell microscopy images. (i)Classification: Across datasets, the SDB fed to an MLP classifier matches learned baselines. (ii)Rotational MRA: Across datasets, the SDB inversion recovers an image from noisy rotated copies. Our results bring to images what the classical bispectrum has long provided for 1D signals: an invariant that is complete, efficient, and invertible, and has proven advantages across downstream tasks.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:46 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
This paper introduces the Selective Disk Bispectrum (SDB), a complex-valued, rotation-invariant image descriptor designed to reduce the computational and spatial complexity of the full disk bispectrum. The authors present strong theoretical contributions, including the first analytic inversion formula for the disk bispectrum, the identification of a minimal sufficient subset of coefficients for exact reconstruction, and a characterization of the descriptor's behavior. The method is evaluated on rotated, noisy MNIST and FashionMNIST datasets, as well as a multi-reference alignment (MRA) task.
The reviewers agree that the paper presents an elegant and mathematically sound theoretical framework. The derivation of an analytic inversion formula is a notable milestone, proving that the disk bispectrum is a complete rotation-invariant representation. Identifying a minimal subset of coefficients successfully reduces the computational bottleneck associated with the traditional disk bispectrum. Moreover, deriving the expectation and variance of the SDB under Gaussian noise provides a rigorous foundation for its application in noisy imaging environments.
Primary weaknesses: Despite the strong theoretical backing, all three reviewers raised significant concerns regarding the method's practical utility and the weakness of its empirical validation.
The most critical flaw identified by the reviewers is that the SDB is strictly invariant to global, perfectly centered rotations. It cannot handle translations, off-center rotations, or local feature rotations. Because real-world applications (like the paper's motivated use cases of cryo-EM and satellite imagery) rarely feature perfectly centered, single-object data, this omission severely limits the descriptor's practical applicability.
The experiments are restricted to low-resolution (up to 112x112), simplistic datasets (MNIST and FashionMNIST) and the paper lacks comparisons to contemporary, learning-based equivariant models (e.g., Steerable CNNs, Harmonic Networks). Finally, reviewer jqS8 questioned whether the mathematical assumptions required for inversion hold reliably in practical image data, and what the consequences are when inversion yields non-zero errors.
Following the detailed rebuttal and the lack of answers from the reviewers, after additional reading I changed the decision to "accept".
Final justification
The authors send a very detailed rebuttal, and mentioned the focus on theory. After additional reading, I changed the final decision to "accept".
Read meta-review
Meta-review
This paper introduces the Selective Disk Bispectrum (SDB), a complex-valued, rotation-invariant image descriptor designed to reduce the computational and spatial complexity of the full disk bispectrum. The authors present strong theoretical contributions, including the first analytic inversion formula for the disk bispectrum, the identification of a minimal sufficient subset of coefficients for exact reconstruction, and a characterization of the descriptor's behavior. The method is evaluated on rotated, noisy MNIST and FashionMNIST datasets, as well as a multi-reference alignment (MRA) task.
The reviewers agree that the paper presents an elegant and mathematically sound theoretical framework. The derivation of an analytic inversion formula is a notable milestone, proving that the disk bispectrum is a complete rotation-invariant representation. Identifying a minimal subset of coefficients successfully reduces the computational bottleneck associated with the traditional disk bispectrum. Moreover, deriving the expectation and variance of the SDB under Gaussian noise provides a rigorous foundation for its application in noisy imaging environments.
Primary weaknesses: Despite the strong theoretical backing, all three reviewers raised significant concerns regarding the method's practical utility and the weakness of its empirical validation.
The most critical flaw identified by the reviewers is that the SDB is strictly invariant to global, perfectly centered rotations. It cannot handle translations, off-center rotations, or local feature rotations. Because real-world applications (like the paper's motivated use cases of cryo-EM and satellite imagery) rarely feature perfectly centered, single-object data, this omission severely limits the descriptor's practical applicability.
The experiments are restricted to low-resolution (up to 112x112), simplistic datasets (MNIST and FashionMNIST) and the paper lacks comparisons to contemporary, learning-based equivariant models (e.g., Steerable CNNs, Harmonic Networks). Finally, reviewer jqS8 questioned whether the mathematical assumptions required for inversion hold reliably in practical image data, and what the consequences are when inversion yields non-zero errors.
Following the detailed rebuttal and the lack of answers from the reviewers, after additional reading I changed the decision to "accept".
Final justification
The authors send a very detailed rebuttal, and mentioned the focus on theory. After additional reading, I changed the final decision to "accept".
- Rating
- 3/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 3/4
- Contribution type
- theory
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposes Selective Disk Bispectrum (SDB), a rotation-invariant image descriptor. The main claim is that SDB is complete/invertible up to global rotation, while being much cheaper than the full disk bispectrum. The paper gives theoretical results for inversion, complexity reduction, approximation error, and noise behavior. Experiments are shown on rotated noisy MNIST/FashionMNIST classification and multi-reference alignment.
Strengths and weaknesses
trengths:
The idea of getting a compact rotation-invariant descriptor without learning the invariance is interesting. The paper also tries to give a stronger guarantee than ordinary invariant descriptors by showing invertibility up to rotation. The selective construction is useful if it really keeps the important information while reducing the full bispectrum cost.
Weaknesses:
The empirical results look marginal. SDB is competitive in some settings, but it is not clearly better across datasets and resolutions, especially compared to strong pretrained features.
The reconstruction/MRA images are not very convincing visually. If the descriptor is claimed to be invertible and information-preserving up to rotation, the reconstruction error and visual quality should be discussed more carefully.
The paper motivates applications like microscopy, satellite imagery, and cryo-EM, but experiments are only on MNIST/FashionMNIST-like data. These are simple centered images. This does not fully support the claimed practical importance for complex real images.
The invertibility is also not perfect in practice. If the inversion has non-zero error, it is important to explain what information is lost or distorted, and whether this matters for complex images.
Questions
- Can the authors explain what information is lost or distorted in the practical inversion when the reconstruction error is non-zero?
- Can the method be tested on a more complex natural-image dataset, such as ImageNet or another dataset where global rotation invariance is meaningful?
- Since the claimed applications involve complex real images, can the authors clarify the practical scope of SDB beyond centered single-object images like MNIST and FashionMNIST?
Limitations
yes
Final justification
I have adjusted the confidence, considering theory contribution type.
Formatting concerns
na
3 comments
I have updated the assessment.
Thank you for the detailed rebuttal and the additional reconstruction and practical-scope results. I have updated my assessment to reflect the Theory contribution type and have given less weight to empirical competitiveness against pretrained features.
The rebuttal clarified the main sources of reconstruction error and provided useful additional comparisons between SDB and the underlying disk-harmonic reconstruction. I also appreciate the clarification of the intended application scope and the additional osteosarcoma-cell experiment.
Accordingly, I revised the significance score to 2, the overall recommendation to Borderline Reject, and the confidence to 3. My remaining reservations concern the practical numerical accuracy of inversion and the limited evidence for broader applicability, but these now carry less weight than in my initial assessment.
Reconstruction stats across 6 datasets, total of 50650 images (inversion accuracy). New experiment: MRA on cell shape images (practical application)
We thank the reviewer for the updated assessment. We address the remaining reservations on reconstruction accuracy and broader applicability of SDB below. Side-by-side reconstructions will appear in the camera-ready. We are happy to provide anonymized links to these figures. Per NeurIPS guidelines we should not post links unless you explicitly request them. Please ask if you would like them.
1. Practical numerical accuracy. Our reconstruction is only as exact as our bispectrum map. Theorem 3 bounds the error between the exact bispectrum and the bandlimited implemented bispectrum by a term that shrinks as the number of pixels grows. We demonstrate this on full evaluation sets across six datasets at , using all osteosarcoma cell silhouettes and the full -image test sets for MNIST, Fashion-MNIST, rotated and translated MNIST, rotated and translated Fashion-MNIST, and CIFAR10. Errors are median relative after rotation registration. Each entry is SDB inversion error (with DHC round-trip error in parentheses).
| dataset | |||||
|---|---|---|---|---|---|
| osteosarcoma cells | 0.259 (0.051) | 0.153 (0.073) | 0.076 (0.030) | 0.086 (0.056) | 0.079 (0.038) |
| CIFAR10 | 0.281 (0.133) | 0.207 (0.160) | 0.144 (0.121) | 0.077 (0.061) | 0.055 (0.044) |
| Fashion-MNIST | 0.342 (0.123) | 0.245 (0.178) | 0.153 (0.115) | 0.059 (0.019) | 0.038 (0.009) |
| rotated and translated Fashion-MNIST | 0.360 (0.138) | 0.305 (0.242) | 0.206 (0.171) | 0.088 (0.044) | 0.053 (0.015) |
| MNIST | 0.446 (0.134) | 0.250 (0.158) | 0.136 (0.085) | 0.064 (0.017) | 0.043 (0.007) |
| rotated and translated MNIST | 0.481 (0.163) | 0.315 (0.203) | 0.163 (0.102) | 0.069 (0.022) | 0.046 (0.009) |
At , a common microscopy image size, every dataset has median SDB error at most . The highest is osteosarcoma cells at and the lowest is Fashion-MNIST at . Osteosarcoma cells already reach at . At this resolution the reconstructed cell morphology is visually not distinguishable from the original. Most residual numerical error is an intensity fade, for example white turning to grey, while structure is preserved. We can corroborate this with an anonymized link to the side-by-side figures if you request it, per NeurIPS guidelines on not sharing links except upon request.
The key point is that SDB error stays close to DHC round-trip error at large . Much of the reconstruction error is already present when we project onto disk harmonics and reconstruct the image, without ever forming the SDB. Selective inversion does not introduce a large new failure mode on top of bandlimiting.
2. Broader applicability of SDB. On real osteosarcoma cell imaging, two tasks show that SDB is usable in the scientific domain.
(A) Cell treatment classification. We classify real mouse osteosarcoma cell silhouettes by treatment on cells, using a split. This is a typical scientific dataset size. Here, there is no canonical upright orientation, so rotation invariance is scientifically meaningful. At , SDB reaches classification accuracy, whereas trained G-CNN, select_gbisp, and tc baselines and frozen DINOv3, EVA, and OpenCLIP encoders near to . At , SDB reaches , again the strongest among those methods. Full tables appear in our response to Reviewer jqS8.
(B) Cell MRA. A second scientific use is multi-reference alignment of cell shapes. Microscopy often yields many randomly rotated noisy copies of one morphology, and the goal is to recover a clean template without knowing the rotations. Because SDB is rotation-invariant, one can average SDB coefficients across observations to suppress noise and then invert the average to obtain an image-space template. The 1D translation invariant bispectrum has been used for this task, but it was not possible for rotated noisy image because the recovery step requires analytic inversion. Without inversion, an average in bispectrum space would not produce a usable cell image.
Centered relative MRA errors on osteosarcoma templates at are reported below. This is a new experiment relative to the Tuesday rebuttal.
| treatment | |||
|---|---|---|---|
| control | 0.064 | 0.051 | 0.068 |
| jasp | 0.084 | 0.067 | 0.110 |
| cytd | 0.152 | 0.252 | 0.207 |
Single-image inversion of control templates stays near to across the same noise levels.
Cell classification and cell MRA are concrete scientific use-cases under the stated assumptions.
If these additions resolve your reservations we would be grateful if you would consider raising your score further. If anything else remains a concern please let us know so we can address it.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- theory
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes the selective disk bispectrum (SDB), a complex-valued rotation-invariant vector that preserves all information about the image except its orientation. Its main theoretical contributions include the construction of the SDB, its inversion, its reduced spatial and computational complexity relative to the full disk bispectrum, and characterizations of its expectation and variance under noise. Experimental results validate SDB's invariance and robustness to noise classification tasks.
Strengths and weaknesses
Strengthes:
- Rotation invariance is important to many computer vision tasks. The paper derives the first analytic inversion formula for the disk bispectrum. This establishes that the disk bispectrum is a complete rotation-invariant representation: it preserves all information about an image except its global orientation.
- The paper identifies a minimal subset of coefficients, called the SDB, that is sufficient for exact image reconstruction up to rotation. As a result, the SDB is a complete invariant: two images have the same SDB if and only if they differ by a planar rotation.
- This paper further derives the expectation and variance of the SDB under i.i.d. Gaussian noise and shows that most SDB coefficients are asymptotically unbiased. This provides a statistical foundation for using the SDB in noisy imaging settings.
Weaknesses:
- The main classification experiments are limited to rotated noisy MNIST and FashionMNIST, with resolutions up to 112×112. It is unclear whether the approach is applicable to broader tasks in more realistic settings.
- The SDB is not invariant to translation, reflection, or local feature rotations. This is a serious practical limitation because many real images are not perfectly centered single-object images.
- It is unclear how well the assumptions like a_{n,1} \neq 0 in the theoretical contributions are satisfied in practice.
Questions
- Can the authors clarify whether the proposed SDB descriptor is expected to scale to more realistic image domains, such as natural images and medical images?
- Since SDB is only invariant to global rotation, how sensitive is the method to translations, off-center objects, reflections, or local rotations of image features?
- Since SDB does not address translation or reflection invariance, how should it be integrated into a practical vision pipeline? Would it require separate registration, centering, or augmentation steps, and how would these affect the claimed efficiency advantages?
Limitations
Yes
Final justification
I went through all the reviews and the authors' rebuttal. All reviewers raised concerns about the applicability of the proposed theory to real-world images. However, the rebuttal only provided additional results on an unreferenced mouse osteosarcoma cell image dataset with three classes. Therefore, this significant concern remains only partially addressed.
Formatting concerns
None
2 comments
Rebuttal
We thank the reviewer for an accurate summary of the theory and for focused questions on translation, the assumption, and practical scope.
1. Translation / centering. You asked how sensitive SDB is to translations and off-center objects, and how it should enter a practical pipeline. We agree: as you noted, SDB is rotation-invariant but not translation-invariant, so uncontrolled translations can change the descriptor. Following your constructive feedback, we ran additional experiments to test the effect of translations on the SDB and its effectiveness in relevant classification. First, we measure translation separability via distances between SDB coefficient vectors. Second, we train classifiers on translated and rotated MNIST. We consider a translation admissible when the object’s support remains inside the computational disk after the translation (no clipping at the disk boundary).
Practical context. At high SNR (for example, histopathology or clean microscopy), centering is cheap and reliable: an intensity center-of-mass or a single registration pass costs in the number of pixels and is already part of most pipelines. At low SNR (for example, cryo-EM), centering can be harder, and particles may retain residual translations. SDB fits settings where reliable centering is available, and next we show that it tolerates residual translations.
Experiment (i): SDB Separability for Translated MNIST. We take one center-of-mass-centered prototype per digit. For each maximum translation radius pixels (, , , , and of the disk diameter , we draw twenty random admissible translations with and compute pairwise distances on the real and imaginary parts of the SDB vectors. Separability is the mean between-digit SDB divided by the mean within-digit distance. A ratio means digit identity remains recoverable; a ratio near means collapse. At , the ratio is .
| max translation | % of disk diameter | SDB sep. after translation |
|---|---|---|
| 0 px | ||
| 1 px | 22.6 | |
| 2 px | 12.8 | |
| 4 px | 7.2 | |
| 8 px | 3.7 |
Even without perfect centering, same-digit SDBs stay clustered at moderate residual translations. Digit identity therefore remains recoverable from distances in SDB space.
Experiment (ii): classification of translated and rotated MNIST. Thank you for raising this point. Following your feedback, we evaluate classification on images that are both rotated and translated with an admissible translation. We also add SE(2) and Harmonic baselines, at the suggestion of Reviewer oCu4. We use and an MLP sized parameters. We report mean$\pm$std over seeds (typically ; a few cells use ), with columns and .
| method | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| SDB | .837±.002 | .743±.039 | .551±.072 | .850±.001 | .812±.021 | .735±.042 | .808±.002 | .772±.034 | .697±.032 |
| G-CNN (max) | .720±.006 | .225±.080 | .177±.075 | .740±.003 | .278±.074 | .175±.064 | .724±.006 | .399±.060 | .243±.055 |
| select_gbisp | .712±.005 | .199±.094 | .163±.085 | .732±.003 | .233±.078 | .158±.062 | .693±.004 | .332±.057 | .201±.048 |
| tc | .761±.002 | .217±.093 | .169±.087 | .788±.003 | .275±.073 | .165±.065 | .757±.004 | .398±.064 | .224±.051 |
| SE(2) | .969±.000 | .613±.203 | .171±.107 | .978±.001 | .903±.061 | .659±.296 | .981±.000 | .919±.048 | .907±.053 |
| Harmonic | .681±.091 | .196±.017 | .145±.018 | .897±.045 | .283±.047 | .188±.025 | .872±.016 | .562±.035 | .273±.052 |
| DINOv3 | .887±.002 | .762±.009 | .483±.030 | .916±.003 | .862±.008 | .744±.006 | .914±.002 | .896±.006 | .848±.008 |
| EVA | .865±.005 | .722±.011 | .440±.029 | .896±.007 | .851±.008 | .727±.006 | .901±.003 | .870±.004 | .827±.006 |
| OpenCLIP | .904±.003 | .764±.006 | .442±.019 | .938±.001 | .896±.004 | .728±.006 | .944±.002 | .928±.005 | .891±.002 |
Under translated and rotated MNIST, SDB stays far above G-CNN, select_gbisp, tc, and Harmonic as noise grows. SE(2) is strongest at larger across noise levels; at it is strong when noiseless but drops sharply as grows. Among pretrained encoders, OpenCLIP and DINOv3 lead at low , while SDB is competitive at higher noise, especially at .
Theory (after experiments). As you noted, SDB is not translation-invariant. More precisely, under an in-disk support condition, it is translation-equivariant at the disk-harmonic and SDB level (proof below). This matters because the change under small admissible translations is structured and continuous in the translation, which explains the clustering in Experiment (i). It does not claim translation invariance.
Take the unit disk with orthonormal basis and coefficients , where . Let the object be supported in a smaller disk with , and zero outside . An admissible translation satisfies , so the translated support stays inside . Define the translated image by on and elsewhere. On this class of images, both and are linear. Expanding in the basis and using linearity gives , where is a fixed matrix depending on and (but not on ), with entries given by inner products of translated basis functions against the original basis. Each SDB coefficient is a fixed triple product of disk-harmonic coefficients, so applying SDB after translation is the same as applying the triple-product map to . Thus SDB is equivariant under admissible translations, not invariant. Center rotations cancel in the triple products, yielding rotation invariance. As , approaches the identity, so slightly translated SDBs stay near the centered SDB and Experiment (i) separability remains at small .
2. The assumption. You asked whether inversion assumptions such as hold in practice. The inversion divides by coefficients such as . That step fails only if (or another needed ) is exactly zero. Exact zeros are pathological edge cases, not what we see for ordinary digit or cell images. Still, we agree it is useful to test these coefficients on our datasets. On 500 MNIST test images and all 650 cell silhouettes at , we find and zero fractions below or (MNIST median ; cells ). For the rare near-zero case, the revision will document this fallback: if is below a threshold, replace the pivot by the first radial index with above that threshold, and add a small ridge in the division if needed.
3. Scientific single-object imaging (osteosarcoma cells). You asked about realistic domains beyond MNIST. Global rotation invariance is most meaningful where there is no canonical “up,” as in cell microscopy, rather than ImageNet-style scenes. Accordingly, we added an experiment classifying mouse osteosarcoma cell images (). Each cell has a label indicating control, or one of two drug treatments (jasp or cytd), for three classes in total. We use a 70/30 train/test split, , and an MLP of size parameters. We add random rotation and report mean$\pm$std over five seeds. SDB with an MLP, and G-CNN / select_gbisp / tc, are trained on the cell task. DINOv3, EVA, and OpenCLIP are pretrained natural-image encoders with only a trained MLP.
| method | |||
|---|---|---|---|
| SDB | () | ||
| G-CNN (max pool) | () | ||
| G-CNN (avg pool) | () | ||
| select_gbisp | () | ||
| tc | |||
| DINOv3 | () | ||
| EVA | () | ||
| OpenCLIP | () |
At and , SDB matches or exceeds the trained pooling baselines and the frozen encoders; all methods are well above chance. For frozen encoders, a natural explanation is domain mismatch (natural-image pretraining versus cell silhouettes). For trained convolutional baselines, the small sample size () is also relevant. This size is typical of scientific datasets.
Notes pointing to other responses. For reconstruction error across 500 MNIST digits, see Reviewer 2hsc.
If our responses have answered your questions, we would be grateful if you would consider raising your score.
Gentle follow-up on translation, inversion assumptions, and cell experiments
Dear Reviewer jqS8,
As the discussion period ends Monday (AoE), we wanted to gently follow up on our rebuttal. It addresses your concerns about translation and centering, the inversion assumption, and practical scientific scope, including admissible-translation separability experiments, classification on rotated and translated MNIST, and osteosarcoma cell treatment classification.
We have sincerely appreciated your careful reading, and we believe these additions have strengthened the paper. Thank you.
If you confirm that our rebuttal resolves your concerns, we would be grateful for a brief acknowledgment and, should you judge it warranted, an updated score. If any questions remain, we would be very happy to clarify them before the deadline.
All the best and thanks again, The Authors
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- theory
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper describes a new rotation-invariant descriptor based on earlier work on the rotation-invariant disk bispectrum. The disk bispectrum applies the concept of the bispectrum to a rotation-invariant transform in which the basis functions are exhibit rotation properties similar to the shift properties of the Fourier transform. This transform has been known to exhibit redundancy, and the paper explores this redundancy to reduce the cost of applying the transform.
Strengths and weaknesses
This is an interesting approach to build a descriptor. The trick for reducing the computational cost and the size of the descriptors is nice and save significant computation. Most of the theoretical heavy lifting has already been done in the development of the disk bispectrum, but the paper provides a very nice enhancement and use case.
However, I think the comparisons in the tables, and especially the experiments are not accurate or fair. There is significant work on rotation-invariant deep learning that avoids a lot of the pitfalls mentioned in the examples in the paper. These include equivariant networks, Steerable CNNs, Equivariant Steerable CNNs and harmonic networks, among others. If the goal is a descriptor (i.e., detection/classification/estimation) the information loss from pooling of equivariant network features is not a problem. The authors seem to dislike trained methods, but trained methods carefully designed to be invariant are likely to outperform their handcrafted generic methods, just by virtue of their adaptation to their data.
With respect to the MRA part, it seems more like preliminary work, rather than a strong point of the paper. While I think the results are very important as an indication that this method works for MRA, the example is slightly formulaic. Practical MRA applications deal with data that are both translated and rotated (sometimes in 3D, but that's a whole other issue) and the proposed method cannot handle rotations off-center and rotations with translations. MRA methods do handle this issue, even if their alignment is more heuristic or not as complete.
Questions
I would expect the authors to provide some more credible comparison with more recent methods (possibly experimental as well, but at least in their exposition. If they decide to keep the multi-reference alignment methods, they should explore it on more realistic scenarios and against state of the art methods.
Limitations
Partly. The authors should address in more detail how the method would work when the data is shifted in addition to being rotated (or is rotated off-axis). Finding the axis of rotation is not as trivial, and the method would suffer.
Formatting concerns
None
2 comments
Rebuttal
We appreciate that the reviewer grasped the computational reduction and selective construction, and thank them for pushing on baselines and MRA scope. We address your concerns below.
Contribution type (Theory track). This submission is Theory-track: the primary contribution is mathematical—analytic inversion, which enables identification of a minimal subset of coefficients (SDB) necessary to completely describe the image. Identifying this minimal subset makes the disk bispectrum computationally tractable. Authors of the original disk bispectrum resorted to PCA on the coefficients to make the size manageable, without completeness guarantees. We provide accuracy guarantees for our implementation, as well as the expectation and variance of the SDB under noise. Empirics illustrate these claims. We respectfully ask that significance be weighed under Theory-track criteria. At the same time, we value the classification and MRA settings as genuine enhancements of the theory.
Equivariant / learned baselines. You asked for comparisons to contemporary learning-based equivariant models (for example, steerable CNNs and Harmonic Networks). We agree the paper should compare to such methods. The submission already situates SDB among basic matched rotation-equivariant learned baselines in escnn, specifically G-CNNs with max and average group pooling, the selective G-bispectrum (select_gbisp), and the triple-correlation (tc). As requested, we have now included SE(2) Networks and Harmonic Networks, and we evaluate them alongside SDB on translated and rotated MNIST. The full table across resolutions and noise levels is in our response to Reviewer jqS8. Here, we summarize the high-resolution setting . At , SE(2) reaches , followed by OpenCLIP at , DINOv3 at , EVA at , Harmonic at , and SDB at , all above G-CNN max, select_gbisp, and tc in the – range. As noise grows, SE(2) remains strongest, with at and at , while SDB reaches and and stays far above G-CNN, select_gbisp, tc, and Harmonic, which collapse toward chance.
MRA. You suggested the MRA section reads as a proof of concept. We agree that the MRA section can be understood as a proof of concept, yet we believe it has value and enhances the paper. Prior translation-bispectrum MRA literature is similarly scoped: those works develop theory and then sweep noise and the number of observations at a single resolution. Our disk/rotation MRA plays the same role. Averaging SDB and inverting recovers a template up to rotation under noise. We will revise the text to make this parallel explicit. Joint SE(2) MRA is future work; see Reviewer jqS8 on translation.
Notes pointing to other responses.
Translated and rotated setting. In our response to Reviewer jqS8, we added separability experiments that show how the SDB changes under translation. We also added classification experiments on translated and rotated MNIST.
Reconstruction quality. In our response to Reviewer 2hsc, we compute SDB reconstruction errors for 500 MNIST digits and assess how much of the reconstruction error comes from the SDB computation versus the disk-harmonic coefficient maps.
Scientific cell-shape evaluation. In our response to Reviewer jqS8, we included a classification experiment on real scientific osteosarcoma cell-shape data (). Each cell is either a control or treated by one of two drugs (jasp / cytd). At and , SDB is competitive with trained G-CNN / select_gbisp / tc and pretrained DINOv3 / EVA / OpenCLIP encoders.
We hope these clarifications address fairness and scope while keeping the theoretical contributions central. If our responses have answered your questions, we would be grateful if you would consider raising your score.
Gentle follow-up on SE(2) / Harmonic baselines and MRA scope
Dear Reviewer oCu4,
With the discussion period closing Monday (AoE), we wanted to gently follow up on our rebuttal. It responds to your requests for stronger equivariant baselines and for clarifying the scope of the MRA section, including new SE(2) and Harmonic Network comparisons on rotated and translated MNIST and a rewritten MRA discussion.
We have sincerely appreciated your feedback, and we believe addressing it has strengthened the paper. Thank you.
If you confirm that our rebuttal resolves your concerns, we would be grateful for a brief acknowledgment and, should you judge it warranted, an updated score. If any questions remain, we would be very happy to clarify them before the deadline.
All the best and thanks again, The Authors
Comments on the paper
2 comments
Additional experiments on translated+rotated images, SE(2) and Harmonic baselines, cell data, and reconstruction, completed at the reviewers’ request
We thank the Area Chair and all reviewers for careful reading and constructive feedback. This global note summarizes the additional work completed during the rebuttal. Detailed numbers, tables, and proofs appear in the individual responses to Reviewers oCu4, jqS8, and 2hsc.
Theory-track framing (Area Chair and all reviewers). This paper was submitted to the Theory track. Its primary contributions are analytic inversion of the disk bispectrum, identification of a minimal complete subset of coefficients called the Selective Disk Bispectrum (SDB), complexity reduction with completeness guarantees, and noise expectation and variance results. The experiments illustrate these claims under the stated single-object and disk-support assumptions. We ask that significance be weighed under Theory-track criteria. At the same time, we treated the reviewers' experimental requests as genuine opportunities to strengthen the paper, and we carried them out.
Translation and centering (Reviewer jqS8). We define a translation as admissible when the object's support remains inside the computational disk after the translation. We measure SDB separability under residual admissible translations on centered MNIST prototypes. For maximum translation radii from 1 to 8 pixels on a disk of diameter 56, the between-digit to within-digit separability ratios range from 22.6 down to 3.7 (Large = better. 1 is bad). Same-digit SDBs therefore remain clustered at moderate residual translations. We also clarify the theory. Under an in-disk support condition, SDB is translation-equivariant rather than translation-invariant. A short proof appears in our response to Reviewer jqS8.
Classification under rotation and translation (Reviewers jqS8 and oCu4). We compare SDB to G-CNN, select_gbisp, tc, SE(2) Networks, Harmonic Networks, and pretrained DINOv3, EVA, and OpenCLIP encoders on translated and rotated MNIST. We report results at resolutions and noise levels . The full table is in our response to Reviewer jqS8, and a high-resolution summary is in our response to Reviewer oCu4. At high resolution with noise, SDB remains far above the G-CNN family and Harmonic Networks. SE(2) is strongest overall. Reviewer jqS8 requested the translated setting, and Reviewer oCu4 requested the SE(2) and Harmonic baselines.
Scientific cell-shape evaluation (Reviewer jqS8). We added a real scientific evaluation on osteosarcoma cell shapes. The dataset has cells with three treatment classes, namely control, jasp, and cytd. At and , SDB with a small MLP is competitive with trained G-CNN, select_gbisp, and tc baselines, and with frozen pretrained encoders. Details appear in our response to Reviewer jqS8.
Reconstruction quality (Reviewer 2hsc). On 500 MNIST digits, we compute both disk-harmonic coefficient round-trip error and SDB inversion error across resolutions and noise levels. Most of the observed error comes from the bandlimited disk-harmonic projection. SDB medians are about to times the corresponding disk-harmonic medians, while coarse structure is preserved. We link these numbers to the visual quality of the paper's MRA reconstructions. In the camera-ready we will add histograms and side-by-side examples using the allowed extra content page.
Inversion assumption (Reviewer jqS8). We checked the inversion assumption . On 500 MNIST images and all 650 cell silhouettes at , the minimum absolute value of exceeds , and the fraction of near-zero coefficients is zero. For rare pathological cases we document a simple radial-index fallback in our response to Reviewer jqS8.
Practical scope and MRA (Reviewers oCu4 and 2hsc). SDB targets single-object images with meaningful global rotation, such as cell microscopy. It is not intended for general natural scenes where upright orientation is already defined. We also affirm that the MRA section is a valued proof of concept in the spirit of prior translation-bispectrum MRA work.
Conclusion These additions directly address the shared concerns on translation, stronger baselines, reconstruction quality, assumption validity, and scientific scope, while keeping the theoretical contributions central. We would be grateful if the Area Chair and reviewers would reconsider their assessments in light of this additional work.
Follow-up: inversion on 50k images and cell-shape MRA
We are adding a short follow up to point out further experiemnts demonstrating numerical accuracy of the inversion, as well as MRA on microscopy cell shapes demonstrating its practical application. Reviewer 2hsc asked about the numerical accuracy of our inversion. To answer this, we took the full test sets of MNIST, Fashion-MNIST, CIFAR10, rotated and translated MNIST, and rotated and translated Fashion-MNIST ( images each), plus all osteosarcoma cell images, for images in total. For each image we computed its SDB and used our inversion to reconstruct the image. We report the median relative reconstruction error after rotation registration, at resolutions . As a baseline, we also map each image to its disk harmonic coefficients and back, without forming the bispectrum. Full tables are in our Official Comment to Reviewer 2hsc. At , every dataset has median SDB error at most , and much of that error is already present in the disk-harmonic round trip.
To show a practical use of SDB beyond a compact descriptor for classification, we also run multi-reference alignment on osteosarcoma cell shapes. Microscopy often yields many randomly rotated noisy copies of one morphology, and the goal is to recover a clean template without knowing the rotations. Because SDB is rotation-invariant, we average SDB coefficients across observations and invert the average to get an image-space template. The 1D translation-invariant bispectrum has been used for this task in several scientific settings, but MRA for rotated 2D images was previously impossible because the recovery step requires analytic inversion. Without inversion, an average in bispectrum space does not yield a usable cell image. At , centered control templates have relative MRA error about to under mild noise. Details are again in the comment to Reviewer 2hsc.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Rebuttal
We thank the reviewer for engaging with invertibility, reconstruction quality, and the gap between motivated applications and MNIST-style empirics.
1. What is lost when practical inversion error is non-zero? You asked what information is lost or distorted when reconstruction error is non-zero. We agree this needs a quantitative answer. In the continuous setting, inversion is exact (completeness up to rotation). Discrete error comes from (i) disk-harmonic bandlimiting / numerical approximation, (ii) observation noise, and (iii) additional error from the selective-bispectrum inverse beyond the DHC round-trip. Completeness is a property of the exact descriptor, not of any single finite bandlimit. We agree that clearly isolating sources of error is important. Following this feedback, we ran new reconstruction experiments comparing the reconstruction error of the SDB to the reconstruction error of the underlying disk harmonic coefficients. Empirically, most error is from the disk-harmonic step (Marshall, Mickelin & Singer, SIAM J. Sci. Comput., 2023; our accuracy guarantees build on theirs—see §4.1). The SDB step then contributes a moderate additional factor (SDB/DHC ratios below).
These results can be compared to our MRA figures for an intuitive sense of what information is lost. At 112×112, the paper’s MRA digits “3” and “4” have relative errors of about 0.17 and 0.20. Those values sit somewhat above the noiseless SDB median of about 0.11, as expected for MRA with noise and a finite number of observations. Digit identity and coarse shape remain; fine edges are softer. We hope that providing this link helps you conceptualize what a relative error of 0.17 and 0.20 looks like in the reconstructed image.
New experiment (SDB vs DHC round-trip). On a 500-image MNIST subset (50 per digit):
Median relative ℓ2 to the clean image:
Both medians fall as L grows. At L=56 with no noise, the DHC projection alone accounts for about 0.11 of the observed 0.16 SDB error. At L=112, the medians fall further to about 0.07 for DHC and 0.11 for SDB. Across settings, SDB error is about 1.3 to 1.6 times the DHC median. Residual error is mostly in high-frequency edge detail, while coarse structure is preserved. In the revision, NeurIPS camera-ready allows one additional content page, and we will add histograms and side-by-side examples as a new figure in the Experiments / numerical approximation subsection (§4), with a pointer from the MRA discussion.
2. Empirical competitiveness. You noted that SDB is not clearly better across every plot vs strong pretrained features. We agree. This is a Theory-track paper: the value is analytic inversion, identification of selective coefficients, completeness, complexity reduction, and noise statistics at low descriptor cost. Empirics illustrate those claims under single-object / disk assumptions, including a useful classification setting. We ask that our paper be scored under theory-track guidelines, as opposed to general-track guidelines.
3. Practical scope. You asked whether SDB is useful beyond centered MNIST-like images. We agree the introduction should not overclaim. SDB targets single-object images such as microscopy, where images are rotated to arbitrary angles, and no canonical "up" direction exists, not general ImageNet scenes where “up” is defined. Under Reviewer jqS8, we provide additional experiments on the real-world task of classifying osteosarcoma cell treatment.
We believe these additions address reconstruction concerns and practical scope. If our responses have answered your questions, we would be grateful if you would consider raising your score.