GRASP: Guided Residual Adapters with Sample-wise Partitioning
Felix Nützel, Mischa Dombrowski, Bernhard Kainz
NeurIPS 2026
TL;DR. GRASP prevents rare-class collapse in long-tail flow matching using static conditioning partitions and residual adapters, improving fidelity, diversity, and downstream classification without changing the objective or sampler.
Abstract. Text-to-image flow matching transformers degrade sharply in long-tail settings: tail-class outputs collapse in fidelity and diversity, limiting their value as synthetic augmentation for rare conditions. We trace this to low head-versus-tail gradient alignment during fine-tuning, an optimization-level pathology that conditioning- and sampling-side interventions do not address. We propose GRASP (Guided Residual Adapters with Sample-wise Partitioning): a deterministic partition of the conditioning space, paired with group-specific residual adapters in the transformer feedforward layers, that leaves the flow-matching objective and the sampler untouched. In conditional flow matching, condition values index distinct sets of probability paths, which makes the conditioning a structurally natural axis along which to factorize residual updates. Because the partition is static, every tail sample is guaranteed to update its assigned expert, which bypasses extreme long-tail failure modes. GRASP is non-invasive and composable: on MIMIC-CXR-LT, combining GRASP with self-guided minority sampling at inference outperforms its learned counterpart on 10 of 12 metrics. GRASP itself reduces overall Fréchet Inception Distance (FID) by up to 80% and lifts tail-class coverage by up to 44% over full fine-tuning, learned-routing mixture-of-experts and long-tail baselines. Performance is stable across random reassignments of labels to experts and across expert counts, as long as no expert is starved of samples. Used as training data for a downstream DenseNet classifier on NIH-CXR-LT, GRASP synthetics significantly outperform every non-GRASP alternative on macro F1 and yield nonzero F1 on 9 of 13 classes versus 3 of 13 from real data, while maintaining comparable macro F1. Results on ImageNet-LT confirm the mechanism is not tied to medical inductive bias. Code is available at \url{https://github.com/Felix-012/GRASP-LT}
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:46 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
This paper proposes GRASP for long-tail text-to-image generation with flow-matching models. GRASP partitions samples using conditioning information and assigns each partition a residual adapter, ensuring that tail samples update a dedicated expert without changing the flow-matching objective or sampler. The paper evaluates the method on long-tailed chest X-ray generation and ImageNet-LT, including downstream classification experiments.
The problem is important, and the proposed method is simple and non-invasive. Static routing is a reasonable way to prevent rare samples from being ignored by a learned gate dominated by head classes. The evaluation covers generation quality, diversity, tail coverage, downstream classification, and gradient consistency, and several of the reported improvements are promising.
The main concern is that the proposed justification is stronger than the evidence. The claim that conditioning provides the “structurally correct factorization” is supported mainly through empirical gradient correlations, while the actual partitions rely on label frequency, text clustering, or manually chosen medical groups. As 4pzK notes, the medical partitions do not appear to align cleanly with the original head/medium/tail definition. The robustness of GRASP to noisy partitions, different numbers of experts, and alternative groupings is therefore unclear.
The comparison with learned routing is also not fully conclusive. MoE performance can depend on expert capacity, gate initialization, balancing losses, and training schedules, and it is unclear whether these baselines received comparable tuning. The set of external long-tail generation baselines is limited, while several comparisons are closer to GRASP ablations. Some configurations and dataset descriptions are also insufficiently specified.
Finally, the downstream classification gains are modest, some extreme-tail classes still have zero F1, and the difference from training with real data is not statistically established. For medical generation, feature-space metrics alone do not demonstrate pathology fidelity. The substantial training cost is another practical limitation.
I currently lean toward rejection. The response could change my assessment if it clarifies the partition construction and experimental configurations, provides convincing partition-sensitivity results, and addresses the fairness of the learned-routing comparisons. The paper should also moderate the theoretical framing unless stronger support can be provided.
Final justification
The rebuttal addresses the main concerns in the first round. The authors clarified that the medical partition is a balanced whole-label grouping rather than a literal head/medium/tail or statistically curated partition. New experiments show similar performance under random reassignments and different expert counts, provided that no expert receives too few samples. The comparison with learned routing is also better controlled: fixed and learned variants use the same experts, capacity, data, schedule, and seeds, while fixed routing consistently uses all experts and performs better on most reported metrics. The hybrid-routing experiment and the additional CCUA baseline further support the empirical case. The authors also clarified the experimental configurations and identified reporting errors that should be corrected in the revision.
All three reviewers rate the paper Borderline Accept. Reviewer niNX maintained the positive rating after the new experiments, and reviewer 4pzK considered the main concerns resolved and moved to Borderline Accept. Thus, I recommend acceptance, conditional on incorporating the new experiments, correcting the experimental descriptions and affected results, and moderating the theoretical and medical claims.
Read meta-review
Meta-review
This paper proposes GRASP for long-tail text-to-image generation with flow-matching models. GRASP partitions samples using conditioning information and assigns each partition a residual adapter, ensuring that tail samples update a dedicated expert without changing the flow-matching objective or sampler. The paper evaluates the method on long-tailed chest X-ray generation and ImageNet-LT, including downstream classification experiments.
The problem is important, and the proposed method is simple and non-invasive. Static routing is a reasonable way to prevent rare samples from being ignored by a learned gate dominated by head classes. The evaluation covers generation quality, diversity, tail coverage, downstream classification, and gradient consistency, and several of the reported improvements are promising.
The main concern is that the proposed justification is stronger than the evidence. The claim that conditioning provides the “structurally correct factorization” is supported mainly through empirical gradient correlations, while the actual partitions rely on label frequency, text clustering, or manually chosen medical groups. As 4pzK notes, the medical partitions do not appear to align cleanly with the original head/medium/tail definition. The robustness of GRASP to noisy partitions, different numbers of experts, and alternative groupings is therefore unclear.
The comparison with learned routing is also not fully conclusive. MoE performance can depend on expert capacity, gate initialization, balancing losses, and training schedules, and it is unclear whether these baselines received comparable tuning. The set of external long-tail generation baselines is limited, while several comparisons are closer to GRASP ablations. Some configurations and dataset descriptions are also insufficiently specified.
Finally, the downstream classification gains are modest, some extreme-tail classes still have zero F1, and the difference from training with real data is not statistically established. For medical generation, feature-space metrics alone do not demonstrate pathology fidelity. The substantial training cost is another practical limitation.
I currently lean toward rejection. The response could change my assessment if it clarifies the partition construction and experimental configurations, provides convincing partition-sensitivity results, and addresses the fairness of the learned-routing comparisons. The paper should also moderate the theoretical framing unless stronger support can be provided.
Final justification
The rebuttal addresses the main concerns in the first round. The authors clarified that the medical partition is a balanced whole-label grouping rather than a literal head/medium/tail or statistically curated partition. New experiments show similar performance under random reassignments and different expert counts, provided that no expert receives too few samples. The comparison with learned routing is also better controlled: fixed and learned variants use the same experts, capacity, data, schedule, and seeds, while fixed routing consistently uses all experts and performs better on most reported metrics. The hybrid-routing experiment and the additional CCUA baseline further support the empirical case. The authors also clarified the experimental configurations and identified reporting errors that should be corrected in the revision.
All three reviewers rate the paper Borderline Accept. Reviewer niNX maintained the positive rating after the new experiments, and reviewer 4pzK considered the main concerns resolved and moved to Borderline Accept. Thus, I recommend acceptance, conditional on incorporating the new experiments, correcting the experimental descriptions and affected results, and moderating the theoretical and medical claims.
1 comment
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The authors propose Guided Residual Adapters with Sample-wise Partitioning (GRASP) for the text-to-image framework, which partitions long-tailed samples into the disjoint conditioning groups (Sample-wise Partitioning) and trains the corresponding expert layers exclusively which are attached to the backbone with residual connection (Guided Residual Adapters). They conduct the image generation task in the MIMIC-CXR-LT, which is a long-tailed medical image dataset, and shows that GRASP outperforms the sampling approach (MG) and the previous MoE-based approach (MoCLE).
Strengths and weaknesses
This work has its strengths in positioning GRASP compared to the previous methods that address long-tailed data in the text-to-image domain.
- While the proposed method utilizes MoE approach with LoRA-like expert layers, it does not require an additional learning objective for the expert weighting thanks to exploiting the training-free and disjoint partitioning by domain priors or text-based grouping.
- Analyses using gradient consistency and correlation (Figure 4) validate that such condition-based partitioning is effective for the consistent training of long-tail sets.
However, it reveals its weaknesses in justifying and clarifying the methodology of GRASP and its evaluation.
- Although the authors spare a considerable amount of Method section in advocating that the proposed conditioning space is "structurally correct factorization," the implementation of GRASP exploits heuristics (head-medium-tail and K-means on text features) and prior knowledge (healthy vs. pathology dichotomy). I do not mind using heuristics based on reasonable priors or analyses, but its framing of such conditioning as "structurally correct factorization" is misleading.
- The proposed partitioning of MIMIC-CXR-LT into the 4 semantic labels does not correspond to the original intention of the dataset in defining the head-medium-tail frequency. Figure 5 in the supplementary material shows that the whole healthy/No Finding data are partitioned to C3, but other partitions (C0 to C2) do not match the number of head, medium, tail stated by Holste, et al [1]. Such partitioning does not match with the statement in Lines 151-152: "experts specialize to frequency regimes rather than single labels."
- The quantitative experiments in Tables 1 to 3 only include two previous works (MG and MoCLE) as baselines; other baselines are basically interpretable as the ablations of GRASP. Such evaluation is insufficient to support the limitations of previous methods in Lines 33-42 and empirically demonstrate the benefit of GRASP.
- Explanations on other baselines and ablation studies are ambiguous. The difference between Adapter and MoE-GRASP, the configurations of GRASP-LowDim and -HighDim, and the conditions of Label, Resample, and Embed in the ablation studies are not stated sufficiently.
[1] Holste, Gregory, et al. "Long-tailed classification of thorax diseases on chest x-ray: A new benchmark study." MICCAI Workshop on Data Augmentation, Labelling, and Imperfections. Cham: Springer Nature Switzerland, 2022.
Questions
- I would like to request more clear explanation about how the original classes from MIMIC-CXR-LT are partitioned into the label-based conditions. Is this related to the original head-medium-tail sort in the original paper?
- Furthermore, please clarify about some baselines, e.g., Adapter, GRASP-LowDim, GRASP-HighDim, in Tables 1 to 3 and some ablation conditions (Label, Resample, Embed) in Table 4 and 5.
- Although Datasets subsection in Experiments mentions that the DenseNet-121 downstream classification task is conducted with NIH-CXR-LT dataset, the captions of Tables 3 and 6 only state the MIMIC-CXR-LT dataset. Please clarify whether these are typos or my misapprehensions to the experiment setups.
- If possible, please add more baselines with related works in the MIMIC-CXR-LT generation task.
Limitations
yes
Final justification
After the authors' responses, I read the paper again and was convinced that the current writing of the proposed partitioning method is addressable during revision. Using the term "frequency-based partitioning" is not technically incorrect, although ambiguous, according to the detailed explanation in the responses, as the authors essentially segregate labels ordered by frequency into disjoint bins. While the proposed method seems sensitive to the partitioning strategy and the number of bins, in my opinion, that is a relatively minor issue compared to my original concerns, which are mostly resolved. Therefore, I adjust my rating to BA and strongly suggest that the authors clarify the partitioning strategy and supplement experiments conducted during the rebuttal in their revision.
Formatting concerns
N/A
3 comments
Rebuttal
Thank you for identifying places where our terminology and experimental definitions were imprecise. We agree the wording was misleading and will revise it. By "structurally correct factorization" we meant the factorization axis, not the optimality of a particular partition: conditional flow matching learns a family of text-condition-indexed probability paths and vector fields, so the conditioning space is the structure-aligned domain on which to factorize residual updates. Our four-way partition is a deliberately simple prior over this domain.
For a fixed condition map , expert receives
which confines each condition's residual updates to its assigned expert, so that samples in other groups cannot alter those parameters. That is all the phrase was meant to claim: it does not require conditions grouped together to have identical gradients, nor assert that only one grouping is valid. The condition-indexed-family argument motivates conditioning as the factorization proxy, while the gradient experiment tests that proxy empirically at the population level.
Q1: Exact label partition and relation to H/M/T. The partition uses two design choices. First, all 53,260 No Finding studies form a dedicated healthy expert, reflecting their majority status and definition. Second, the pathology labels are divided into three groups, with the number suggested by the H/M/T convention. The partition uses balanced partitioning of a Jaccard-kNN label graph under a ~1.5$\times$ size constraint. This is effectively a balanced label binning, not a frequency-thresholded or clinically curated H/M/T routing as might have been implied by our wording. Consequently, related labels may be separated and common and rare labels may share an expert. Literal H/M/T routing would be poorly supported here: the three official tail labels contain only 71 samples under a 4,438:1 imbalance, so we did not adopt it, and the control below confirms that it degrades. We used the described partition without searching over alternatives from the very beginning. The exact routing is:
| Expert | train samples | complete label composition |
|---|---|---|
| E0 | 11,506 | Support Devices; Edema; Pneumonia; Pneumothorax; Lung Lesion; Fracture; Enlarged Cardiomediastinum |
| E1 | 9,243 | Lung Opacity; Consolidation; Pleural Other; Calcification of the Aorta; Tortuous Aorta; Pneumoperitoneum; Subcutaneous Emphysema; Pneumomediastinum |
| E2 | 13,484 | Cardiomegaly; Atelectasis; Pleural Effusion |
| E3 | 53,260 | No Finding |
The revision will define by this lookup and describe the two decisions separately, rather than through the shorthand you flagged.
New controls support our intended claim. They are reassignments within this same construction: each random map keeps the four experts, the reserved healthy expert, and every label wholesale in one expert, and fills the three pathology bins toward the same target loads as the submitted map, so only the choice of which labels share an expert is randomised, fixed across training and evaluation. All rows share the GRASP-LowDim width, optimizer, training and 50k-image evaluation budget, and three classifier seeds.
| Fixed condition partition | experts | smallest expert | label-macro DINO-FID ↓ | macro-F1 ↑ | nonzero classes |
|---|---|---|---|---|---|
| Clustered partition (submitted) | 4 | 9,243 | 150.59 | .0769 | 9/13 |
| Random reassignment, mean of 3 maps | 4 | 7,927 | 139.63 | .0797 | 9/13 (pooled) |
| Fewer pathology groups | 3 | 17,080 | 149.65 | .0746 | 8/13 |
| More pathology groups | 5 | 8,431 | 150.67 | .0850 | 8/13 |
| Literal official H/M/T | 3 | 71 | 317.55 | .0707 | 2/13 |
| One expert per label | 19 | 12 | 447.19 | .0734 | 5/13 |
Consequently, the submitted partition is one member of a family that performs comparably. Random reassignment of whole conditions at the same expert count and width gives a similar point estimate (.0797 against .0769), and the three- and five-group variants stay close while changing total capacity. The two designs that starve an expert are the two that degrade, which also explains why we do not route by the official H/M/T strata. Our claim is not that the submitted partition is optimal, but that it is one viable, non-starved choice.
Q2: Definitions of the compared configurations.
Adapteris one shared sequential residual adapter, without partition-specific routing.GRASP-LowDimuses four fixed-routed bottleneck-16 residual experts in all 19 dual-stream and 38 single-stream Flux blocks, that is, an adapter at every layer.GRASP-HighDimuses full-dimensional fixed-routed residual experts in the final four dual-stream blocks, based on the design proposed by Dong et al. [10].MoE-GRASPholds GRASP's groups, experts, residual architecture, data, optimizer, steps and seeds fixed, and replaces the deterministic group-to-expert lookup with a learned top-1 gate.- In Tables 4/5,
Labelmeans the fixed label grouping above;Embedmeans a static grouping obtained by bisecting k-means (cosine) over frozen text-conditioning embeddings, which is also the routine used for ImageNet-LT;Resamplemeans round-robin resampling of three batch items, prioritizing the least-used groups and guaranteeing every expert at least one sample per training step.
We will add these definitions, or make them more prominent, in the paper. The matched MoE-GRASP ablation also resolves the capacity ambiguity: both variants have four experts and 53,236,480 expert parameters, and the learned version adds a 512-parameter gate that can represent the fixed assignment. Yet its checkpoints use only two to three of the four experts in every seed and always place the dominant healthy group with pathology groups. Fixed against learned gives DINO-FID 91.36 against 97.73 and macro-F1 .0769 against .0728 for LowDim, and 67.32 against 72.65 and .0801 against .0711 for HighDim. So under this matched, otherwise untuned protocol fixed routing is a robust tuning-free default for tail coverage.
Q3: Tables 3/6 dataset clarification. The captions are typos. The classifier is trained on synthetic images generated from the 23,550 MIMIC-CXR-LT test prompts, then tested on the NIH-CXR-LT test set filtered to the 13 labels shared with MIMIC-CXR-LT (16,506 of 20,279 NIH images). We chose this cross-dataset design to limit memorization effects from report-to-image generation. We will correct both captions and the dataset paragraph, where 20,279 is currently attributed to MIMIC-CXR-LT although it is the size of the full NIH-CXR-LT test set. The revision will also correct the GRASP-LowDim + MG row, whose values were taken from the learned-router run rather than the fixed router that combination uses. Regenerated with the fixed router, it improves on every label-macro metric (DINO-FID 142.0 against 151.4, CXR-FID .039 against .051, DINO IRS .429 against .412) and on four of six all-label metrics (DINO-FID 83.99 against 90.6, CXR IRS .679 against .632), the two exceptions being all-label DINO IRS at .200 against .218 and all-label CXR-FID at .0135 against .012. No conclusion changes.
Q4: Additional external baseline. We add CCUA (Chen et al., ref. [6]), which was cited in the submission but not experimentally compared, at a comparable wall-clock budget and without checkpoint selection:
| Method | DINO-FID ↓ | CXR-FID ↓ | macro-F1 ↑ | nonzero classes |
|---|---|---|---|---|
| GRASP-LowDim | 91.36 | .01394 | .0769 | 9/13 |
| CCUA | 116.77 | .06772 | .06785 | 1/13 |
The feature rows use three generator seeds and the downstream rows pool nine generator-classifier runs. GRASP leads on every column and recovers 9 of 13 downstream classes against 1.
Together, the added comparison, the exact configuration definitions, the partition audit and the routing and sensitivity experiments support the paper's intended claim without asserting that the partition is uniquely optimal. Since most of your points concern how the method and setup were described rather than what was run, we would appreciate knowing whether the definitions are clearer now, and we will carry them into the revision in this form.
Thanks for your response to the review, with additional experiments and explanations that address my concerns in Q2 to Q4.
Yet, the answer to Q1 admits that the partition used for MIMIC-CXR-LT is based on a clustering algorithm available for a multi-label dataset, although the writing in this submission consistently states that the proposed partition is augmented from the frequency-based partition (Lines 155-156, 171-173, and 539-542). Furthermore, multi-label-based clustering naturally implies clinical curation, i.e., correlation among diseases.
I would be grateful if the authors could clarify the intention or context of the aforementioned statements.
Thank you for your reply. First, we would like to clarify that the MIMIC/NIH-LT version we use is strictly single label and not multi-label. You can check out the split here: https://github.com/VITA-Group/LongTailCXR/tree/main (in particular mimic-cxr-lt_single-label_train.csv in labels). So there is no co-occurrence term used for the partitioning, which means the partitioning is effectively label-binning with a balancing constraint. This is also clearly evident from the partition itself, which separates labels such as Pleural Effusion and Pleural Other, or Cardiomegaly and Enlarged Cardiomediastinum.
However, it is true that our wording used to describe the partitioning is inaccurate, and something that should be corrected for the camera-ready version. Thank you for bringing this to our attention. We deliberately did not focus on the exact partitioning procedure, since we did not want to imply that the algorithm played any role in the partitioning outcome. It was only a tool to get a label-based partition with a balancing factor. The frequency-based description is based on two things: the native choice of three experts for the disease classes (with our addition of the healthy expert) and the fact that the partition we used is essentially frequency-ordered: If we rank the 18 pathologies by training frequency, one expert consists of frequency ranks 2-4, one consists of frequency ranks 5-11, and one consists of frequency rank 1 + 12-18. So it is effectively frequency-binned with the most common disease moved to the tail expert for balancing reasons (resulting in an imbalance factor of 1.46:1 instead of 16:1). In our earlier response we focused mostly on the balancing aspect.
So the description of the partitioning was inaccurate, but importantly, does not change any numbers, results or implications in our paper.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposes GRASP, a static routing method for long-tail text-to-image flow matching. It partitions samples according to conditioning information, such as label frequency or text embeddings, and assigns each group to residual adapters inserted into transformer feedforward layers. Different from learned MoE routing, GRASP uses fixed sample-wise partitioning to ensure that tail samples update their assigned expert.
Strengths and weaknesses
Strengths
- The motivation is clear and easy to follow. Long-tail generation is important, especially for rare medical conditions.
- The method is simple and non-invasive. It keeps the original flow-matching objective and sampler unchanged, only adding group-specific residual adapters.
- The static routing idea is intuitive. Compared with learned routing, it can avoid tail samples being ignored by a gate dominated by head-class gradients.
- The experiments are relatively comprehensive, including image quality/diversity metrics, downstream classification, ablations on partitioning/resampling, and gradient-consistency analysis.
Weaknesses:
- The novelty is limited. The key components, including adapters, MoE-style routing, label-frequency grouping, and long-tail sampling, are all well explored. GRASP is mainly a static version of routed adapters for long-tail generation.
- The downstream classification gains are modest. Even with GRASP, several extreme-tail classes still collapse to zero F1, and the macro-F1 improvement over real data or strong baselines is small.
- The evaluation relies heavily on feature-space metrics such as FID, IRS, and coverage. For medical image generation, these metrics may not fully reflect clinical correctness or pathology fidelity.
- The comparison with learned routing is not fully convincing. MoE-GRASP and MoCLE may be sensitive to routing capacity, initialization, balancing loss, and training schedule. It is unclear whether the failure of learned routing is fundamental or due to implementation choices.
Questions
-
How sensitive is GRASP to the partition strategy? If the label-frequency bins or text clusters are noisy, does the method still outperform learned routing? A stronger partition robustness study would raise my confidence.
-
Can the authors provide a fairer comparison with learned-routing MoE methods? For example, tuning the gate, load-balancing loss, or expert capacity would clarify whether static routing is truly better or whether the learned-routing baselines are under-optimized.
Limitations
yes
Formatting concerns
NA
1 comment
Rebuttal
Thank you for recognizing GRASP’s motivation and simplicity. We position its contribution narrowly: it is neither a new generator nor an adapter primitive, nor a universal alternative to learned MoEs. Our finding is that, under extreme imbalance, assigning each condition to one sufficiently supported expert is more stable than asking a gate trained on the same imbalanced signal to learn the allocation. CFM naturally supports condition-wise factorization because it learns prompt-conditioned probability paths. A previously used gradient-consistency metric ranks GRASP, MoCLE, and the shared adapter in the same order as downstream performance.
Q1: Partition sensitivity. Our partitioning is not hand-curated. One expert is reserved for the healthy group, so all No Finding studies route to it, and the 18 pathology labels are split into three groups by a balanced -way graph partition of a Jaccard-kNN graph over class names treated as sets, under a ~1.5$\times$ size constraint. That second step is a label binning balanced in aggregate sample count with each class belonging to a single expert. To test sensitivity, we added several alternative fixed partitions under the same GRASP-LowDim width, optimizer, training and 50k-image evaluation budget, randomizing which labels share an expert while keeping the map fixed across training and evaluation:
| Fixed condition partition | experts | smallest expert | label-macro DINO-FID ↓ | macro-F1 ↑ | nonzero classes |
|---|---|---|---|---|---|
| Clustered partition (paper) | 4 | 9,243 | 150.59 | .0769 | 9/13 |
| Random reassignment, mean of 3 maps | 4 | 7,927 | 139.63 | .0797 | 9/13 (pooled) |
| Fewer pathology groups | 3 | 17,080 | 149.65 | .0746 | 8/13 |
| More pathology groups | 5 | 8,431 | 150.67 | .0850 | 8/13 |
| Literal official H/M/T | 3 | 71 | 317.55 | .0707 | 2/13 |
| One expert per label | 19 | 12 | 447.19 | .0734 | 5/13 |
This supports robustness across sufficiently supported partitions: random assignments perform similarly, so GRASP does not depend on recovering our grouping. The method fails when experts are under-supported. MIMIC-CXR-LT has a 4,438:1 imbalance, and its three official tail labels contain only 71 samples, making both a literal tail expert and 19 per-label experts impractical.
Q2: Fairness to learned routing. Our matched comparison, GRASP-LowDim versus MoE-GRASP-LowDim, keeps the groups, experts, capacity, bottleneck, adapter locations, backbone, data, optimizer, schedule, steps, and seeds fixed. MoE-GRASP only replaces the fixed assignment with a 512-parameter top-1 gate that can represent it. We use the strongest reported router hyperparameters without method-specific tuning. Fixed routing improves most metrics, such as DINO-FID and macro-F1 in both LowDim (91.36 vs. 97.73; .0769 vs. .0728) and HighDim (67.32 vs. 72.65; .0801 vs. .0711), implying that fixed routing better preserves broad tail utility here.
We also initialized the learned gate near GRASP while training adapters from scratch. Instead of drifting away, its diagonal probabilities rose from about .90 to .920–.924, and all 76 modules retained the identity top-1 map throughout training. Macro-F1 remained similar (.0814), while class recovery fell from 9/13 to 6/13. Thus, collapse depends on initialization, as you suggest, but a gate given a viable static solution does not improve it under this protocol.
Weaknesses: downstream utility and pathology fidelity. We agree that absolute macro-F1 gains are modest. GRASP-HighDim (.0801) is comparable to real-data training (.0786), not significantly superior. The clearer long-tail result is class coverage: a DenseNet trained on GRASP synthetics achieves nonzero real-test F1 on 9/13 classes, versus 3/13 after real-data training. GRASP recovers six classes missed by real training and loses none in the reverse direction (directional , two-sided ).
Finally, at comparable wall-clock cost, GRASP-LowDim also outperforms CCUA: 91.36 vs. 116.77 DINO-FID, .01394 vs. .06772 CXR-FID, .0769 vs. .06785 macro-F1, and 9/13 vs. 1/13 recovered classes.
We are happy to expand on any of these points during the discussion period.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 4/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The authors propose 'GRASP (Guided Residual Adapters with Sample-wise Partitioning)' for improving long-tail text-to-image generation. The framework does not alter flow-matching objective or sampling, making it a deployable module for existing diffusion and flow-matching models. The results on datasets such as ImageNet-LT showcase improvements in diversity and FID.
Strengths and weaknesses
- technically sound, with thorough experiments
- non-invasive, with minor modifications to flow matching
- great explanation of motivation, addressing the important challenge of long-tail text-to-image generation
- performance improvement is convincing across various datasets
- Core assumption is empirical rather than mathematical / theoretically established
- robustness of proposed method (generalizability) is uncertain, with more downstream experiments to be done, thus is interesting but not significant enough to medical imaging community.
Questions
-
Your work is based on the assumption that a similar condition = a similar gradient. You provided empirical evidence via gradient consistency. Can you establish: under what assumption conditioning similarity implies gradient similarity? Some cosine-similarity analysis between partitions may be intuitive.
-
The effectiveness of GRASP depends on quality of predefined partition. Do you have a threshold that when would performance degrade when partition becomes noisy?
-
Your results show that static routing performs better on tail classes. Have you considered hybrid strategy (e.g. initialize with static then finetune), such that you can maintain tail-class coverage while recovering head-class performance?
-
How sensitive are the results to the number of experts?
Limitations
-
You mainly compared with MoCLE but lack comparison with recent diffusion MoE frameworks (e.g. Dense2MoE https://openaccess.thecvf.com/content/ICCV2025/html/Zheng_Dense2MoE_Restructuring_Diffusion_Transformer_to_MoE_for_Efficient_Text-to-Image_Generation_ICCV_2025_paper.html) With too many degree-of-freedom, it's hard to tell if performance increase comes from adapter architecture, # of parameters , or else.
-
The design of partition still are artificial. In certain real-world applications like medical (healthy/pathological) fields, the model may lack domain knowledge and cannot maintain generalizability. (In your figure 3, only chest X-ray results are shown - not sure if other clinical image modalities like CT/MRI/Ultrasound etc. are still valid)
-
In your table 3, Macro-F1: real data = .079, while GRASP-HighDim = .080. The outperformance is not significant.
-
Line 565-570: to replicate your experiment need lots of H100 GPU hours. (240 GPU H100 hours per seed) The computational cost is concerning.
-
Lack of strong reasoning for your core assumption. Current proof mainly comes from empirical observation (figure 4b). See my first question in 'Questions' above.
Final justification
I keep my rating with the new experiments provided in rebuttal. This rating is my final decision.
Formatting concerns
Paper formatted well. Please expand the acronyms at their first appearance, if possible.
2 comments
Rebuttal
Thank you for your questions. We first recap our claim in the paper: in conditional flow matching the condition indexes a family of probability paths and vector fields, and a fixed routing map gives the update isolation
so samples outside group cannot modify its residual parameters, while the frozen backbone retains shared structure. We do not assume that nearby conditions have identical gradients, nor that our four-way partition is uniquely optimal.
Q1: When should conditioning similarity imply gradient similarity? Our claim does not depend on the pairwise similarity of individual sample gradients, but on whether the dominant parameter-space direction of a condition subset is represented in the overall optimization direction. We therefore use gradient consistency as defined by Dong et al. [10].
Following their definition, the dominant parameter-space direction of a sample set is , where is the principal eigenvector of the tangent kernel , and gradient consistency is the cosine between and for the subset routed to expert . It therefore measures how well the dominant direction of aligns with that of the full data. In long-tail training, low consistency means the direction a rare subset needs is poorly represented in the dominant one, which Dong et al. [10] attribute to domination by common data.
GRASP only changes which parameter block receives which samples' gradients, so the question is whether the updates an expert receives still represent what its conditions need. That is a relation between a subset and the aggregate, which is what gradient consistency computes. Pairwise cosine instead measures how homogeneous a group is internally. Our bins are balanced by size and mix frequent with rare labels, so within-group similarity is low by construction and is not a property the method needs.
Our hypothesis has two parts: routing helps when isolating condition families raises the consistency of their dominant update directions relative to a shared adapter, and greater consistency goes with better learning of the conditions routed to an expert. Figure 4 is consistent with both, since consistency orders GRASP above MoCLE above the shared adapter and the downstream results follow the same order.
Q2/Q4: Partition noise and number of experts. Our partitioning has two parts. One expert is reserved for the healthy group, so all 53,260 No Finding studies route to it. The 18 pathology labels are then split into three groups, the count following the head/medium/tail convention, by a balanced -way graph partition over class names treated as sets under a ~1.5$\times$ size constraint. In effect this is a label binning balanced in aggregate sample count (11,506 / 9,243 / 13,484): each label is assigned to a single expert, and the largest and rarest pathologies can share one. Four experts in total.
The controls below are reassignments within this construction. Each random map keeps the four experts, the reserved healthy expert, and every label wholesale in one expert, and fills the three pathology bins toward the same target loads as the submitted map, so only the choice of which labels share an expert is randomised, fixed across training and evaluation. All rows use the GRASP-LowDim width, optimizer, fixed steps, 50k-image evaluation budget and three classifier seeds.
| Fixed condition partition | experts | smallest expert | label-macro DINO-FID ↓ | label-macro CXR-FID ↓ | macro-F1 ↑ | nonzero classes |
|---|---|---|---|---|---|---|
| Clustered partition (paper) | 4 | 9,243 | 150.59 | .03684 | .0769 | 9/13 |
| Random reassignment, mean of 3 maps | 4 | 7,927 | 139.63 | .03681 | .0797 | 9/13 (pooled) |
| Fewer pathology groups | 3 | 17,080 | 149.65 | .04059 | .0746 | 8/13 |
| More pathology groups | 5 | 8,431 | 150.67 | .03927 | .0850 | 8/13 |
| Literal official H/M/T | 3 | 71 | 317.55 | .07538 | .0707 | 2/13 |
| One expert per label | 19 | 12 | 447.19 | .04956 | .0734 | 5/13 |
The results are consistent with minimum expert support mattering. Every configuration whose smallest expert holds at least about 8k samples stays close to ours on both macro metrics and recovers 8 to 9 of 13 classes, whereas both starved designs degrade, label-macro DINO-FID doubling or tripling and recovery dropping to 2/13 and 5/13. Reassignment gives a similar point estimate to ours (.0797 against .0769), so the grouping is not what produces the result.
Q3: Fixed versus learned routing, and degrees of freedom. Our matched routing ablation is GRASP against MoE-GRASP: four residual experts, 53,236,480 expert parameters, bottleneck 16, all 19 dual and 38 single Flux blocks, frozen backbone, and the same data, batch size, learning rate, schedule, steps and seeds. MoE-GRASP only replaces the fixed lookup with a trainable top-1 gate, adding 512 parameters, and that gate can represent the fixed assignment.
| Routing (identical experts, data, schedule, seeds) | label-macro DINO-FID ↓ | all-label DINO-FID ↓ | macro-F1 ↑ | nonzero classes | experts used |
|---|---|---|---|---|---|
| Fixed, LowDim | 150.59 | 91.36 | .0769 | 9/13 | 4/4 |
| Learned top-1 gate, LowDim | 153.64 | 97.73 | .0728 | 7/13 | 2-3/4 |
| Fixed, HighDim | 107.70 | 67.32 | .0801 | 8/13 | 4/4 |
| Learned top-1 gate, HighDim | 113.93 | 72.65 | .0711 | n/a | 2-3/4 |
Fixed routing leads in both aggregations and both widths. On Dense2MoE, that work restructures the transformer into an MoE for efficient generation, changing the architecture and several capacity variables at once, so it does not isolate the routing question; the matched ablation above does. We will discuss it and narrow our scope accordingly.
We also ran the suggested hybrid: adapters were trained from scratch for the same number of steps, with only the gate initialized to route each condition to its GRASP expert at approximately .90 confidence. The gate moved further toward GRASP: diagonal probabilities reached .920–.924, and all 76 modules retained the identity top-1 map at every checkpoint. Macro-F1 was similar (.0814), but class recovery fell from 9/13 to 6/13. Thus, this matched protocol found no overall better assignment.
GRASP itself is a minimal intervention. Despite this, at comparable wall-clock cost over three seeds, GRASP also outperforms CCUA [6]: 91.36 vs. 116.77 DINO-FID, .01394 vs. .06772 CXR-FID, .0769 vs. .06785 macro-F1, and 9/13 vs. 1/13 recovered classes. Therefore, its gains are not explained by parameter count or heavier training.
Limitations: significance, generality, and compute. We did not establish that .0801 exceeds real-data training (.0786) significantly, and will replace "matches/outperforms real" with a point-estimate statement. The intended long-tail result is recovery breadth: GRASP-LowDim has nonzero F1 on 9 of 13 classes against 3 of 13 for real training, recovering six classes for which real training gives zero and losing none in the reverse direction (exact directional , two-sided ), which we report as an exploratory paired class-recovery test. GRASP applies to ImageNet-LT, so the method is not CXR-specific, though CT, MRI and ultrasound remain untested.
The pretrained FLUX model is indeed compute-heavy, but it's a common default backbone choice. Our method itself does not intrinsically depend on that choice. GRASP is cheap and produces almost no compute overhead compared to standard adapter-based fine-tuning. The partition itself is computed offline, within seconds for the label-based variant and minutes for bisecting k-means.
Your first question in particular made us state the optimization claim more carefully, and we would gladly go into more detail on the gradient-consistency analysis or on any of the new partition runs during the discussion period.
Thank you for your structured response and new results. Youe LaTex equations are not shown properly in the comment boxes, making it a bit harder to understand.
I am mostly convinced by your controlled experiment, with different # of experts and random partitions. I am not fully confirmed by your explanation of your theoretical assumption. I appreciate your honestly towards real-data superiority and generalization.
Overall, I keep my positive rating.
Comments on the paper
1 comment
Reminder: Phase 2 Discussion — Please Respond to Rebuttals by Aug 3
Dear Reviewers,
A quick reminder that the Phase 2 author–reviewer–AC discussion runs through Aug 3. Please read the rebuttals for your assigned papers and post a brief reply — even a short note on whether your concerns were addressed is very helpful for the final evaluation. If you've already responded, thank you, and please watch for any author follow-ups.
As always, let's engage the way we'd hope reviewers would with our own work: careful reading, a constructive tone, and an open mind toward new evidence.
Thank you for your continued effort and service.
Best,
Your AC
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
For clarity, we briefly summarize the main findings from the rebuttal:
Sensitivity Analysis: Random whole-label reassignments and different expert counts perform comparably to the partition in our paper unless they are intentionally starved.
Hybrid Approach: The gate does not learn a new assignment and class recovery falls from 9/13 to 6/13.
Fixed vs Learned Routing: For both adapter variants, fixed routing improves most metrics and recovers more classes.
External Baseline: GRASP improves on CCUA for 13 out of 14 metrics.
Synthetic vs Real GRASP reaches 9/13 versus 3/13, gaining six classes and losing none (directional p=.0156, two-sided p=.0313), while maintaining comparable macro-F1 in our experiments.
Theoretical framing: By "structurally correct factorization," we do not want to imply optimality or identical gradients. Merely that conditioning is a natural factorization axis in flow matching. Fixed routing guarantees update isolation, while our experiments provide empirical support. We will use "structurally natural" in the revision.
Compute Cost: Both the offline partitioning and the adapters produce minimal overhead. The frozen FLUX backbone as a standard architecture choice itself is the compute-intensive part and not a requirement of GRASP.
Partition Details: The label partition was not tuned or selected for optimality. We used one fixed whole-label grouping, balanced across the pathology experts, without searching over alternative partitions. The result is a balanced, labelwise, approximately frequency-binned partition.
Full Result Tables
Partition sensitivity (GRASP-LowDim, 10k steps, 50k images)
The submitted partition uses three generator seeds (nine runs). Each variant uses one generator seed with three classifier seeds, with random class recovery pooled for comparability.
Fixed vs learned routing (identical experts, data, schedule, seeds)
Same experts, same 53,236,480 parameters (+ 512 for the gate).
External baseline
Exact partition