potentialpaper

CMPQ: Compensatory Quantization via Input-Aware Hessian Damping

DENG PAN, Grigorii Khvatskii, Xiaobao Huang, Peiyu Li, Shangqian Gao, Ting Hua, Nitesh V. Chawla

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. CMPQ reframes activation corruption in quantization as evidence of unreliable input directions, reshaping the calibration curvature to redirect compensation onto clean subspaces.

Abstract. As large language models (LLMs) scale, post-training weight quantization (PTQ) has become a standard tool for deploying them on commodity hardware with little loss in quality. However, existing quantization solvers such as GPTQ calibrate each weight matrix against a corrupted signal: the calibration input observed at any deep layer is the output of the cumulative quantized chain, not a clean full-precision reference. We propose \textbf{CMPQ (Compensatory Quantization)}, which reframes the corruption as evidence about \emph{which input directions have become unreliable} and tells the solver to stop spending its compensation budget on them. CMPQ measures the divergence between the quantized and full-precision input and uses it to reshape the curvature that GPTQ already relies on, redirecting compensation onto weights attached to clean input subspaces and cutting the propagation path of upstream noise. On the Qwen3 family at three sizes (4B / 8B / 14B), CMPQ improves over GPTQ and is competitive with GPTAQ at 3-bit; at 2-bit, where GPTQ and AWQ collapse to near-random accuracy, it outperforms all baselines.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
4 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]—[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:44 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

(a) Summary of claims/findings

  • Paper proposes CMPQ, a weight-only PTQ method addressing the discrepancy between full-precision and quantized-chain activations that arises from accumulated upstream quantization error in Hessian-based solvers like GPTQ.
  • Argues that GPTAQ's first-order residual correction approach itself introduces disruption, since the correction term depends on already-altered weights, causing correction-target drift as running weights change during column-wise quantization (56WM, ouA1).
  • CMPQ instead estimates the activation discrepancy between quantized and full-precision chains and folds it into the GPTQ Hessian as an input-aware, noise-covariance damping term, leaving the rest of the GPTQ pipeline (solver, checkpoint format, inference path) unchanged.
  • Evaluated on Qwen3-Base 4B/8B/14B under 2-bit and 3-bit weight-only quantization, showing improvements over GPTQ/AWQ/GPTAQ, primarily at 2-bit.

(b) Strengths

  • Identifies a meaningful, well-motivated limitation of existing Hessian-based PTQ methods (Hessians built from quantization-corrupted calibration activations) (56WM, Wwb2, ouA1).
  • The proposed fix is simple, elegant, and easy to integrate — it only modifies the Hessian and is usable as a plug-in to existing pipelines (GPTQ, QuIP) without altering the solver or checkpoint format (56WM, Wwb2, ouA1).
  • Well-written (56WM).
  • Shows convincing improvement at 2-bit quantization, the setting where quantization degradation is typically most severe (56WM, ouA1).

(c) Weaknesses

  • Unjustified zero-mean noise assumption: the method's core motivation relies on an assumption that upstream quantization noise (ξ) is zero-mean; no empirical evidence (e.g., layer-wise discrepancy statistics) is provided to support this across layers, model families, or bit-widths (56WM, Wwb2 — both explicitly request this).
  • Narrow experimental scope: evaluation is limited to the Qwen3-Base family only (4B/8B/14B); generalization to other architectures (LLaMA, Mistral, DeepSeek) is untested (56WM, Wwb2, ouA1 — all three raise this).
  • Incomplete/weak baseline comparison: no comparison against stronger recent 2-bit methods (e.g., QuIP#, other incoherence-based approaches), which the authors themselves acknowledge as a limitation (56WM, Wwb2).
  • Inconsistent results at 14B: GPTAQ surpasses CMPQ on the 14B model, and lower perplexity doesn't correlate with higher accuracy in that case — unexplained and raises concerns about whether results generalize or are cherry-picked (56WM).
  • Limited practical advantage: 2-bit gains are notable but the setting remains far below BF16 in absolute terms; at 3-bit, GPTAQ reportedly performs better overall, so CMPQ's practical advantage over existing methods isn't fully established (ouA1).
  • Insufficient comparison to closely related work: CAE, which shares similar motivation (addressing GPTAQ's correction-target drift), is not discussed in relation to CMPQ's differences or comparative performance (ouA1).
  • Hyperparameter selection protocol unclear: the selection of a key hyperparameter (γ) may have been tuned on the same benchmarks used for final evaluation, risking benchmark leakage/overfitting; a held-out validation set is recommended (ouA1).
  • Mechanism not isolated: it's unclear whether CMPQ's gains stem from the specific noise-aware Hessian structure or simply from a general damping/numerical-stability effect of adding a positive term to the Hessian; comparison against isotropic/diagonal damping baselines is needed to isolate this (ouA1).
  • Design choices under-justified: trace normalization and other design choices lack sufficient justification (56WM).
  • Missing efficiency metrics: no wall-time or peak memory measurements, especially for larger models (56WM).

(d) What could change the outcome in rebuttal

  • Empirical evidence (e.g., layer-wise statistics) supporting the zero-mean noise assumption for ξ (56WM, Wwb2).
  • Results on additional model families (LLaMA, Mistral, DeepSeek) and a broader range of model sizes to establish generality beyond Qwen3 (56WM, Wwb2, ouA1).
  • Comparison against stronger 2-bit baselines (e.g., QuIP#) to properly position CMPQ's competitiveness (56WM, Wwb2).
  • Explanation of the 14B anomaly (GPTAQ outperforming CMPQ) and confirmation that results are reproducible/not cherry-picked (56WM).
  • Ablation isolating the noise-aware Hessian structure from a generic damping effect (e.g., vs. isotropic/diagonal damping) (ouA1).
  • Clarification of the hyperparameter (γ) selection protocol, ideally with a held-out validation set separate from final evaluation benchmarks (ouA1).
  • Discussion/comparison with CAE to clarify CMPQ's distinct contribution (ouA1).
  • Wall-time and peak-memory measurements, particularly at larger scale (56WM).
Final justification

All three reviewers converge on nearly positive assessments after a thorough rebuttal process. The rebuttal substantively strengthened the paper: broader generalization evidence, direct empirical support for the core theoretical assumption, a clean ablation isolating the mechanism from confounds, and reasonable clarification of related-work positioning. Remaining gaps (combined experiments with QuIP#/CAE, broader efficiency benchmarking, PPL/variance on new models) are appropriately characterized by reviewers as camera-ready-level extensions rather than fundamental flaws. Authors are encouraged to incorporate the promised combined-method experiments and broader efficiency/variance reporting into the camera-ready version.

Area Chair LwBw · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

(a) Summary of claims/findings

  • Paper proposes CMPQ, a weight-only PTQ method addressing the discrepancy between full-precision and quantized-chain activations that arises from accumulated upstream quantization error in Hessian-based solvers like GPTQ.
  • Argues that GPTAQ's first-order residual correction approach itself introduces disruption, since the correction term depends on already-altered weights, causing correction-target drift as running weights change during column-wise quantization (56WM, ouA1).
  • CMPQ instead estimates the activation discrepancy between quantized and full-precision chains and folds it into the GPTQ Hessian as an input-aware, noise-covariance damping term, leaving the rest of the GPTQ pipeline (solver, checkpoint format, inference path) unchanged.
  • Evaluated on Qwen3-Base 4B/8B/14B under 2-bit and 3-bit weight-only quantization, showing improvements over GPTQ/AWQ/GPTAQ, primarily at 2-bit.

(b) Strengths

  • Identifies a meaningful, well-motivated limitation of existing Hessian-based PTQ methods (Hessians built from quantization-corrupted calibration activations) (56WM, Wwb2, ouA1).
  • The proposed fix is simple, elegant, and easy to integrate — it only modifies the Hessian and is usable as a plug-in to existing pipelines (GPTQ, QuIP) without altering the solver or checkpoint format (56WM, Wwb2, ouA1).
  • Well-written (56WM).
  • Shows convincing improvement at 2-bit quantization, the setting where quantization degradation is typically most severe (56WM, ouA1).

(c) Weaknesses

  • Unjustified zero-mean noise assumption: the method's core motivation relies on an assumption that upstream quantization noise (ξ) is zero-mean; no empirical evidence (e.g., layer-wise discrepancy statistics) is provided to support this across layers, model families, or bit-widths (56WM, Wwb2 — both explicitly request this).
  • Narrow experimental scope: evaluation is limited to the Qwen3-Base family only (4B/8B/14B); generalization to other architectures (LLaMA, Mistral, DeepSeek) is untested (56WM, Wwb2, ouA1 — all three raise this).
  • Incomplete/weak baseline comparison: no comparison against stronger recent 2-bit methods (e.g., QuIP#, other incoherence-based approaches), which the authors themselves acknowledge as a limitation (56WM, Wwb2).
  • Inconsistent results at 14B: GPTAQ surpasses CMPQ on the 14B model, and lower perplexity doesn't correlate with higher accuracy in that case — unexplained and raises concerns about whether results generalize or are cherry-picked (56WM).
  • Limited practical advantage: 2-bit gains are notable but the setting remains far below BF16 in absolute terms; at 3-bit, GPTAQ reportedly performs better overall, so CMPQ's practical advantage over existing methods isn't fully established (ouA1).
  • Insufficient comparison to closely related work: CAE, which shares similar motivation (addressing GPTAQ's correction-target drift), is not discussed in relation to CMPQ's differences or comparative performance (ouA1).
  • Hyperparameter selection protocol unclear: the selection of a key hyperparameter (γ) may have been tuned on the same benchmarks used for final evaluation, risking benchmark leakage/overfitting; a held-out validation set is recommended (ouA1).
  • Mechanism not isolated: it's unclear whether CMPQ's gains stem from the specific noise-aware Hessian structure or simply from a general damping/numerical-stability effect of adding a positive term to the Hessian; comparison against isotropic/diagonal damping baselines is needed to isolate this (ouA1).
  • Design choices under-justified: trace normalization and other design choices lack sufficient justification (56WM).
  • Missing efficiency metrics: no wall-time or peak memory measurements, especially for larger models (56WM).

(d) What could change the outcome in rebuttal

  • Empirical evidence (e.g., layer-wise statistics) supporting the zero-mean noise assumption for ξ (56WM, Wwb2).
  • Results on additional model families (LLaMA, Mistral, DeepSeek) and a broader range of model sizes to establish generality beyond Qwen3 (56WM, Wwb2, ouA1).
  • Comparison against stronger 2-bit baselines (e.g., QuIP#) to properly position CMPQ's competitiveness (56WM, Wwb2).
  • Explanation of the 14B anomaly (GPTAQ outperforming CMPQ) and confirmation that results are reproducible/not cherry-picked (56WM).
  • Ablation isolating the noise-aware Hessian structure from a generic damping effect (e.g., vs. isotropic/diagonal damping) (ouA1).
  • Clarification of the hyperparameter (γ) selection protocol, ideally with a held-out validation set separate from final evaluation benchmarks (ouA1).
  • Discussion/comparison with CAE to clarify CMPQ's distinct contribution (ouA1).
  • Wall-time and peak-memory measurements, particularly at larger scale (56WM).
Final justification

All three reviewers converge on nearly positive assessments after a thorough rebuttal process. The rebuttal substantively strengthened the paper: broader generalization evidence, direct empirical support for the core theoretical assumption, a clean ablation isolating the mechanism from confounds, and reasonable clarification of related-work positioning. Remaining gaps (combined experiments with QuIP#/CAE, broader efficiency benchmarking, PPL/variance on new models) are appropriately characterized by reviewers as camera-ready-level extensions rather than fundamental flaws. Authors are encouraged to incorporate the promised combined-method experiments and broader efficiency/variance reporting into the camera-ready version.

Reviewer ouA1OpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
2/4
Significance
3/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper addresses the discrepancy between the input activations of the full-precision and quantized models caused by quantization errors accumulated in preceding layers during weight-only post-training quantization. The authors argue that GPTQ does not explicitly exploit the structure of this upstream activation discrepancy, while direct residual correction methods such as GPTAQ may suffer from correction-target drift as the running weights change during column-wise quantization. To address these limitations, CMPQ constructs noise-aware statistics from the activation difference between the quantized and full-precision chains and incorporates them into the GPTQ Hessian to modify the quantization objective. The method preserves the original GPTQ column-wise solver, quantized checkpoint format, and inference pipeline, requiring additional computation only during calibration. The authors evaluate CMPQ on Qwen3-Base models with 4B, 8B, and 14B parameters under 2-bit and 3-bit weight-only quantization and report improved performance over existing methods.

Strengths and weaknesses

Strengths

  • The proposed method is simple and can be integrated into the existing GPTQ solver by modifying only the Hessian.

  • CMPQ shows meaningful improvements over GPTQ and GPTAQ in the challenging 2-bit setting, where quantization typically causes substantial performance degradation.

Weaknesses

  • The motivation for revisiting GPTQ could be clarified. In GPTQ, the calibration input XX for the current layer is obtained after quantizing the preceding layers and thus already reflects upstream quantization errors. This is also consistent with inference, where the current layer receives activations from quantized upstream layers. The authors argue that GPTQ relies too heavily on a single corrupted realization, but the resulting limitation at test time is not directly formalized or analyzed.

  • CAE [15] and the proposed method share a similar motivation, as both aim to address the drift of the correction target in GPTAQ. However, the manuscript does not provide a detailed discussion of how the two methods differ or how their performance compares. Such a discussion would help clarify the contribution of CMPQ.

  • The protocol for selecting λ\lambda could be described more carefully. The manuscript evaluates several values of λ\lambda and reports the one with the best average zero-shot performance. If the same tasks are used for both selection and final evaluation, this may introduce tuning on the evaluation benchmarks. Reporting results with a separate validation set would make the evaluation more convincing.

  • The practical benefit of CMPQ appears limited. Although CMPQ shows larger gains at 2-bit precision, this setting may be difficult to use in practice because its performance remains far below BF16. At 3-bit precision, GPTAQ appears to perform better overall. Therefore, the practical advantage of CMPQ over existing methods is not yet fully demonstrated.

  • The experiments are limited to the Qwen3-Base family. Experiments on additional model families, such as Llama or Mistral, and with multiple calibration seeds would provide stronger evidence of generality and robustness.

  • The effect of Hessian augmentation could be analyzed further. Adding a positive term to the Hessian in Eq. (11) may improve numerical stability by increasing small eigenvalues and making matrix inversion or Cholesky decomposition more stable. It is therefore unclear whether the gains mainly come from the noise-aware structure of ΔXΔX⊤\Delta X \Delta X^\top or from a general damping effect. Comparisons with isotropic and diagonal damping would help isolate the benefit of the proposed regularization.

Questions

I have no additional questions. I would appreciate it if the authors could adequately address the concerns raised in the Weaknesses section. If these concerns are resolved satisfactorily, I would be willing to increase my rating.

Limitations

Yes

Final justification

Thank you for the detailed rebuttal. Most of my concerns have been adequately addressed. However, the lack of direct combination experiments with CAE or QuIP# remains a limitation. I am therefore raising my rating from 3 to 4, as the remaining experimental gap still prevents me from assigning a 5.

Formatting concerns

No

4 comments
Authors · CommentOpenReview ↗

Q1: "The motivation for revisiting GPTQ could be clarified. In GPTQ, the calibration input XX for the current layer is obtained after quantizing the preceding layers and thus already reflects upstream quantization errors. This is also consistent with inference, where the current layer receives activations from quantized upstream layers. The authors argue that GPTQ relies too heavily on a single corrupted realization, but the resulting limitation at test time is not directly formalized or analyzed."

A1. Calibration observes one realization of the quantized-chain activation (128 sequences). At deployment the layer receives a different realization of the same upstream-noise process — different tokens, hence a different ΔX\Delta X. GPTQ fits its Hessian to the single observed realization, so it is free to spend compensation budget on directions dominated by the particular noise draw in the calibration set — expenditure that does not transfer to a fresh draw.

What we want is a W^\hat{W} whose reconstruction error is small in expectation over the noise process, not at the calibration snapshot; Eq. (9) is exactly that expectation, and VV is the covariance of the process estimated from the calibration set, which is why the correction enters as curvature rather than as a residual. This makes the contribution a calibration-to-deployment generalization argument rather than a "corrupted signal" argument.

Q2: "CAE [15] and the proposed method share a similar motivation, as both aim to address the drift of the correction target in GPTAQ. However, the manuscript does not provide a detailed discussion of how the two methods differ or how their performance compares. Such a discussion would help clarify the contribution of CMPQ."

A2. CAE and CMPQ start from the same observation: GPTAQ's residual is defined against the running weight W(q)W^{(q)} rather than W(0)W^{(0)}, but they intervene at different places. CAE acts inside the column loop: it re-anchors the per-column residual to W(0)W^{(0)}, so the correction is first-order in ΔX\Delta X (the discrepancy enters linearly) and it must track the solver state, keeping W(0)W^{(0)} and W(q)W^{(q)} separate as quantization proceeds. CMPQ instead acts before the column loop: it replaces the Hessian HH with H^=H+λrV\hat{H} = H + \lambda r V, so the discrepancy enters at second order as a covariance rather than as a linear residual, and H^\hat{H} is fixed before quantization starts and carries no dependence on solver state.

Q3: "The protocol for selecting λ\lambda could be described more carefully. The manuscript evaluates several values of λ\lambda and reports the one with the best average zero-shot performance. If the same tasks are used for both selection and final evaluation, this may introduce tuning on the evaluation benchmarks. Reporting results with a separate validation set would make the evaluation more convincing."

A3. Thanks for this valuable advice. We agree that using the same zero-shot tasks for both selecting λ\lambda and reporting final results would risk tuning on the evaluation benchmarks. In our protocol, λ\lambda is selected using WikiText-2 perplexity, while zero-shot accuracy is used only for evaluation. This separates hyperparameter selection from the downstream evaluation tasks. Empirically, the choice is also not very sensitive: the λ\lambda-response curve is relatively flat across the tested range, so nearby values give similar performance.

Q4: "The practical benefit of CMPQ appears limited. Although CMPQ shows larger gains at 2-bit precision, this setting may be difficult to use in practice because its performance remains far below BF16. At 3-bit precision, GPTAQ appears to perform better overall. Therefore, the practical advantage of CMPQ over existing methods is not yet fully demonstrated."

A4. There are two complementary sides for the quantization problem: rounding-side and solver-side. For example, the famous QuIP# acts on the rounding side which achieving significantly better results than traditional rounding, but still requires a solver for calibration. CMPQ acts on the solver side: which quadratic form the column-wise compensation minimizes. Our claim is therefore not “CMPQ along can perform reasonably at 2-Bit” but "CMPQ improves the solver that can be combined with rounding methods like QuIP#": the two families compose rather than compete.

Authors · CommentOpenReview ↗

Q5: "The experiments are limited to the Qwen3-Base family. Experiments on additional model families, such as Llama or Mistral, and with multiple calibration seeds would provide stronger evidence of generality and robustness."

A5. For additional experiments, we have run CMPQ and baselines on llama2-13B, Qwen2.5-7B and Mistral-Nemo-12B. As the results show, under 2-bit, CMPQ show advantage in most zero-shot metrics.

  • LLama2-13B 2-bit
method ARC-c ARC-e BoolQ HS PIQA WG ZS avg
GPTQ 22.61 35.23 57.37 37.66 60.07 50.59 43.92
GPTAQ 30.97 54.34 68.65 55.67 70.62 60.14 56.73
CMPQ 33.79 57.15 66.18 55.76 71.44 60.77 57.51
  • Qwen2.5-7B 2-bit
method ARC-c ARC-e BoolQ HS PIQA WG ZS avg
GPTQ 24.66 30.93 48.38 36.72 53.81 48.86 40.56
GPTAQ 32.76 57.15 67.28 48.12 67.63 60.77 55.62
CMPQ 33.62 61.11 65.63 57.85 71.33 61.09 58.44
  • Mistral-Nemo-12B 2-bit
method ARC-c ARC-e BoolQ HS PIQA WG ZS avg
GPTQ 22.70 28.49 41.47 28.22 51.85 48.93 36.94
GPTAQ 24.66 43.10 66.15 51.79 64.31 55.25 50.88
CMPQ 28.07 48.91 66.48 48.96 62.46 56.35 51.87

Q6: "The effect of Hessian augmentation could be analyzed further. Adding a positive term to the Hessian in Eq. (11) may improve numerical stability by increasing small eigenvalues and making matrix inversion or Cholesky decomposition more stable. It is therefore unclear whether the gains mainly come from the noise-aware structure of ΔXΔX⊤\Delta X \Delta X^\top or from a general damping effect. Comparisons with isotropic and diagonal damping would help isolate the benefit of the proposed regularization."

A6. We have now run this ablation. To isolate structure at matched magnitude, we hold the damping energy fixed — trace normalization enforces tr⁡(damping)=λ tr⁡(H)\operatorname{tr}(\text{damping}) = \lambda\,\operatorname{tr}(H) exactly — and vary only the form of the added matrix:

  • Isotropic: λ (tr⁡(H)/d) I\lambda\,(\operatorname{tr}(H)/d)\,I, which in our implementation is exactly GPTQ's own percdamp raised to matched trace;
  • Diagonal: diag⁡ ⁣(∑nΔX:,n2)\operatorname{diag}\!\big(\sum_n \Delta X_{:,n}^2\big), the same source signal with the off-diagonal structure removed;
  • Full VV: ΔXΔX⊤\Delta X \Delta X^\top, the proposed term.

Qwen3-8B, 2-bit, everything else identical (WikiText-2 perplexity / zero-shot average):

λ\lambda Isotropic Diagonal Full VV (ours)
0.1 31.01 / 55.40 68.67 / 48.50 23.46 / 59.69
1 49.73 / 50.80 6870 / collapsed 23.02 / 59.52
Reviewer ouA1 · CommentOpenReview ↗

Thank you for the detailed rebuttal. Many of my concerns have been addressed or clarified. My understanding is that CMPQ could be combined with complementary methods such as CAE and QuIP#. It would have been helpful to see some experiments on these combinations. I will consider raising my score after discussing the paper and the remaining concerns with the other reviewers and the Area Chair.

Authors · CommentOpenReview ↗

Thank you again for your thoughtful follow-up. As the discussion period is about to close, we wanted to kindly ask whether you have had a chance to revisit your assessment in light of the rebuttal and subsequent discussion. We would greatly appreciate any final feedback, and we would be happy to clarify any remaining concerns.

Reviewer Wwb2OpenReview ↗
Rating
3/6
Confidence
4/5
Quality
2/4
Clarity
3/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes CMPQ, a weight-only PTQ method for LLMs. The main motivation is that existing Hessian-based solvers such as GPTQ construct the Hessian using calibration activations from the already-quantized forward chain. These activations are corrupted by upstream quantization noise and therefore differ from the clean full-precision activations. To address this issue, CMPQ estimates the activation discrepancy between the quantized chain and the full-precision chain, uses this discrepancy to construct a noise covariance term, and adds it to the standard GPTQ Hessian as an input-aware damping component. The paper evaluates CMPQ on three Qwen3-Base models, including 4B, 8B, and 14B, under 2-bit and 3-bit weight-only quantization settings. The results show that CMPQ brings improvements over GPTQ and AWQ in the 2-bit setting.

Strengths and weaknesses

Strengths:

  1. The paper identifies a meaningful limitation of existing Hessian-based PTQ methods. It points out that GPTQ constructs the Hessian using activations from the already-quantized forward chain, which may contain accumulated upstream quantization noise rather than clean full-precision activations.

  2. The proposed method is simple and easy to integrate. CMPQ only modifies the Hessian by adding a noise covariance term estimated from the discrepancy between the quantized and full-precision activation chains.

Weakness:

  1. The motivation relies on a strong zero-mean noise assumption. However, the paper does not provide sufficient empirical evidence that the upstream quantization noise is actually zero-mean across different layers, model families, or bit-widths.

  2. The experimental scope is narrow. The main evaluation is conducted only on the Qwen3 family. It is unclear whether the method generalizes to other model families such as LLaMA, Mistral, or DeepSeek.

  3. The baseline comparison is incomplete. The paper does not compare against stronger recent 2-bit quantization methods, such as QuIP# or other incoherence-based approaches. I am sure there are lots of 2bit PTQ methods for LLM. This makes it difficult to assess whether CMPQ is competitive with the strongest low-bit PTQ methods.

Questions
  1. The method relies on the assumption that upstream activation noise is approximately zero-mean. Could the author provide empirical evidence for this assumption, for example by reporting layer-wise statistics of the activation discrepancy between the quantized and full-precision?

  2. How sensitive is CMPQ to the calibration data? It would be helpful to know whether the method remains stable across different calibration samples or random seeds.

Limitations

Please refer to Weaknesses and Question part

Formatting concerns

NA

3 comments
Authors · CommentOpenReview ↗

Q1: "The motivation relies on a strong zero-mean noise assumption. However, the paper does not provide sufficient empirical evidence that the upstream quantization noise is actually zero-mean across different layers, model families, or bit-widths."

A1. We have now measured it directly. Writing μ=1T∑tΔX:,t\mu = \frac{1}{T}\sum_t \Delta X_{:,t}, the damping term's trace splits as

tr⁡(ΔX ΔX⊤)=T∥μ∥2+tr⁡(centered second moment)\operatorname{tr}(\Delta X\,\Delta X^\top) = T\|\mu\|^2 + \operatorname{tr}(\text{centered second moment})

so ρ=T∥μ∥2/∑t∥ΔX:,t∥2∈[0,1]\rho = T\|\mu\|^2 / \sum_t \|\Delta X_{:,t}\|^2 \in [0,1] is exactly the fraction of tr⁡(V)=tr⁡(ΔX ΔX⊤)\operatorname{tr}(V)=\operatorname{tr}(\Delta X\,\Delta X^\top) explained by a nonzero mean: ρ≈0\rho \approx 0 means the plug-in estimator in Eq. (8) is empirically harmless; ρ→1\rho \to 1 means VV is dominated by a systematic shift. Measured on every linear layer (7 per block) at 2-bit:

Model Layers Median ρ\rho Mean ρ\rho p90 Max
Qwen3-8B-Base 249 0.1066 0.1099 0.202 0.360
Qwen3-14B-Base 277 0.0692 0.0822 0.155 0.380
LLaMA-2-13B 277 0.1069 0.1248 0.201 0.637

So for the typical layer roughly 90% of tr(V) is genuine centered second moment (median ρ ≈ 0.07–0.11 across all four models); even at the 90th-percentile layer the mean contributes only ~16–21%, and the worst single layer 36–64%. The pattern is stable across both model families with Llama models slightly worse in worst-case scenarios.

Q2: "The experimental scope is narrow. The main evaluation is conducted only on the Qwen3 family. It is unclear whether the method generalizes to other model families such as LLaMA, Mistral, or DeepSeek."

A2. For additional experiments, we have run CMPQ and baselines on llama2-13B, Qwen2.5-7B and Mistral-Nemo-12B. As the results show, under 2-bit, CMPQ show advantage in most zero-shot metrics.

  • LLama2-13B 2-bit
method ARC-c ARC-e BoolQ HS PIQA WG ZS avg
GPTQ 22.61 35.23 57.37 37.66 60.07 50.59 43.92
GPTAQ 30.97 54.34 68.65 55.67 70.62 60.14 56.73
CMPQ 33.79 57.15 66.18 55.76 71.44 60.77 57.51
  • Qwen2.5-7B 2-bit
method ARC-c ARC-e BoolQ HS PIQA WG ZS avg
GPTQ 24.66 30.93 48.38 36.72 53.81 48.86 40.56
GPTAQ 32.76 57.15 67.28 48.12 67.63 60.77 55.62
CMPQ 33.62 61.11 65.63 57.85 71.33 61.09 58.44
  • Mistral-Nemo-12B 2-bit
method ARC-c ARC-e BoolQ HS PIQA WG ZS avg
GPTQ 22.70 28.49 41.47 28.22 51.85 48.93 36.94
GPTAQ 24.66 43.10 66.15 51.79 64.31 55.25 50.88
CMPQ 28.07 48.91 66.48 48.96 62.46 56.35 51.87

Q3: "The baseline comparison is incomplete. The paper does not compare against stronger recent 2-bit quantization methods, such as QuIP# or other incoherence-based approaches. I am sure there are lots of 2bit PTQ methods for LLM. This makes it difficult to assess whether CMPQ is competitive with the strongest low-bit PTQ methods."

A3. QuIP/QuIP# are not alternatives to CMPQ on the same subproblem. QuIP# acts on the **rounding side (incoherence processing via Hadamard rotations, lattice codebooks, etc.), whereas CMPQ acts on the solver side: which quadratic form the column-wise compensation minimizes. QuIP#'s own pipeline runs an GPTQ-style adaptive rounding step inside the rotated basis, and the Hessian that step consumes is built from exactly the quantized-chain activations we analyze. So CMPQ's modification applies there unchanged. Our claim is therefore not "CMPQ beats QuIP#" but "CMPQ improves the solver that QuIP# also relies on": the two families compose rather than compete. We will revise Section 2 and the Limitations to state this explicitly and commit to a combined CMPQ + QuIP# experiment in the camera-ready, which we believe is more informative than a side-by-side ranking.

Authors · CommentOpenReview ↗

Q4: "The method relies on the assumption that upstream activation noise is approximately zero-mean. Could the author provide empirical evidence for this assumption, for example by reporting layer-wise statistics of the activation discrepancy between the quantized and full-precision?"

A4. Please see A1

Q5: "How sensitive is CMPQ to the calibration data? It would be helpful to know whether the method remains stable across different calibration samples or random seeds."

A5. We have now run a full seed study on Qwen3-8B-Base at 2-bit, re-drawing the calibration set with four different seeds and re-running the entire pipeline end-to-end for both CMPQ and GPTAQ.

seed WT2 C4 ARC-c ARC-e BoolQ HS PIQA WG ZS-Avg
42 23.46 23.49 39.51 66.75 65.87 53.97 71.06 61.01 59.69
0 25.03 22.78 35.41 53.11 69.39 54.55 67.90 61.25 56.94
1 24.43 22.93 36.18 62.50 67.09 54.44 70.57 61.09 58.64
7 24.66 23.36 36.52 64.02 67.03 54.18 71.33 62.12 59.20
mean 24.40 23.14 36.90 61.60 67.35 54.29 70.21 61.37 58.62
std 0.67 0.34 1.80 5.92 1.47 0.26 1.57 0.51 1.20
  • GPTAQ
seed WT2 C4 ARC-c ARC-e BoolQ HS PIQA WG ZS-Avg
42 25.62 24.95 32.17 59.60 63.55 44.19 67.68 58.01 54.20
0 22.23 22.33 32.08 58.21 63.12 47.40 68.23 59.67 54.78
1 24.48 23.74 29.18 40.66 65.96 45.74 63.71 59.51 50.79
7 33.39 24.89 29.95 58.04 65.20 46.33 68.44 59.43 54.56
mean 26.43 23.98 30.84 54.12 64.46 45.91 67.02 59.16 53.59
std 4.85 1.23 1.51 9.01 1.35 1.34 2.23 0.77 1.88
Authors · CommentOpenReview ↗

Thank you again for your constructive review. In our rebuttal, we provided empirical layer-wise evidence regarding the zero-mean assumption, additional experiments on LLaMA-2-13B, Qwen2.5-7B, and Mistral-Nemo-12B, clarification of the relationship between CMPQ and QuIP/QuIP#, and a four-seed calibration study. As the discussion period is about to close, we wanted to kindly ask whether these additions address your main concerns. We would greatly appreciate any final feedback and, if appropriate, reconsideration of your assessment.

Reviewer 56WMOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The method aims to account for disturbance in activations in adaptive-quantization pipelines like GPTQ. Unlike GPTAQ, in which authors propose to add a first-order correction to the weights’ updates, CMPQ claims that GPTAQ itself introduces disruption, because the correction term includes the partially altered weights. CMPQ proposes a more elegant approach: include the expected activation disturbance in the Hessian estimation, leaving other components of the algorithm intact.

Strengths and weaknesses

Strengths

  • This is an interesting and elegant method, which aims to compensate for cumulative noise from quantizing earlier layers.
  • Can be used as a plug-in to an existing adaptive-quantization pipelines (GPTQ, QUIP), since it only alters the Hessian estimation.
  • Shows convincing results on 2-bit quantization, with the exception of perplexity results on 14B model. (See questions)
  • The paper is well-written.

Weaknesses

  • Limited comparison, as authors themselves note in Limitations. Given that there are no stronger baselines for 2-bit quantization (for example, Quip, Quip# (even without vector-quantization and fine-tuning)), the comparison could be broadened by the model sizes and families.
  • Lack of justification for some design choices like trace normalization and zero-mean ξ .
Questions
  • Can you provide more measurement concerning the walltime and peak memory (larger models)?
  • Why does the GPTAQ surpass CMPQ on 14B model? Does it happen on larger models? Why the lower perplexity doesn’t correlate in this case with higher accuracy? Could you provide results on broader range of model sizes and architectures to strengthen the claim and make sure the results are not cherry -picked and are reproducible outside small qwen models? The needs to be some empirical justification for assuming ξ is zero-mean. Can you add some experiments supporting that?
Limitations

See questions

Formatting concerns

no

3 comments
Authors · CommentOpenReview ↗

Q1: "Limited comparison, as authors themselves note in Limitations. Given that there are no stronger baselines for 2-bit quantization (for example, Quip, Quip# (even without vector-quantization and fine-tuning)), the comparison could be broadened by the model sizes and families."

A1. QuIP/QuIP# are not alternatives to CMPQ on the same subproblem. QuIP# acts on the rounding side (incoherence processing via Hadamard rotations, lattice codebooks, etc.), whereas CMPQ acts on the solver side: which quadratic form the column-wise compensation minimizes. QuIP#'s own pipeline runs an GPTQ-style adaptive rounding step inside the rotated basis, and the Hessian that step consumes is built from exactly the quantized-chain activations we analyze. So CMPQ's modification applies there unchanged. Our claim is therefore not "CMPQ beats QuIP#" but "CMPQ improves the solver that QuIP# also relies on": the two families compose rather than compete. We will revise Section 2 and the Limitations to state this explicitly and commit to a combined CMPQ + QuIP# experiment in the camera-ready, which we believe is more informative than a side-by-side ranking.

For additional experiments, we have run CMPQ and baselines on llama2-13B, Qwen2.5-7B and Mistral-Nemo-12B. As the results show, under 2-bit, CMPQ show advantage in most zero-shot metrics.

  • LLama2-13B 2-bit
method ARC-c ARC-e BoolQ HS PIQA WG ZS avg
GPTQ 22.61 35.23 57.37 37.66 60.07 50.59 43.92
GPTAQ 30.97 54.34 68.65 55.67 70.62 60.14 56.73
CMPQ 33.79 57.15 66.18 55.76 71.44 60.77 57.51
  • Qwen2.5-7B 2-bit
method ARC-c ARC-e BoolQ HS PIQA WG ZS avg
GPTQ 24.66 30.93 48.38 36.72 53.81 48.86 40.56
GPTAQ 32.76 57.15 67.28 48.12 67.63 60.77 55.62
CMPQ 33.62 61.11 65.63 57.85 71.33 61.09 58.44
  • Mistral-Nemo-12B 2-bit
method ARC-c ARC-e BoolQ HS PIQA WG ZS avg
GPTQ 22.70 28.49 41.47 28.22 51.85 48.93 36.94
GPTAQ 24.66 43.10 66.15 51.79 64.31 55.25 50.88
CMPQ 28.07 48.91 66.48 48.96 62.46 56.35 51.87

Q2: "Lack of justification for some design choices like trace normalization and zero-mean ξ\xi."

A2. Two design choices are named; we justify each.

Trace normalization. Its purpose is to give uniform interpretation across layers (line 159), since ∣∣V∣∣||V|| will increase when layers are deeper, the damping effect will increase if we do not normalize. Empirically it is also worth +0.47 ZeroShot at 3-bit and +0.30 at 2-bit on Qwen3-14B (Table 3).

Zero-mean noise. We have now measured it directly. Writing μ=1T∑tΔX:,t\mu = \frac{1}{T}\sum_t \Delta X_{:,t}, the damping term's trace splits as

tr⁡(ΔX ΔX⊤)=T∥μ∥2+tr⁡(centered second moment)\operatorname{tr}(\Delta X\,\Delta X^\top) = T\|\mu\|^2 + \operatorname{tr}(\text{centered second moment})

so ρ=T∥μ∥2/∑t∥ΔX:,t∥2∈[0,1]\rho = T\|\mu\|^2 / \sum_t \|\Delta X_{:,t}\|^2 \in [0,1] is exactly the fraction of tr⁡(V)=tr⁡(ΔX ΔX⊤)\operatorname{tr}(V)=\operatorname{tr}(\Delta X\,\Delta X^\top) explained by a nonzero mean: ρ≈0\rho \approx 0 means the plug-in estimator in Eq. (8) is empirically harmless; ρ→1\rho \to 1 means VV is dominated by a systematic shift. Measured on every linear layer (7 per block) at 2-bit:

Model Layers Median ρ\rho Mean ρ\rho p90 Max
Qwen3-8B-Base 249 0.1066 0.1099 0.202 0.360
Qwen3-14B-Base 277 0.0692 0.0822 0.155 0.380
LLaMA-2-13B 277 0.1069 0.1248 0.201 0.637

So for the typical layer roughly 90% of tr(V) is genuine centered second moment (median ρ ≈ 0.07–0.11 across all four models); even at the 90th-percentile layer the mean contributes only ~16–21%, and the worst single layer 36–64%. The pattern is stable across both model families with Llama models slightly worse in worst-case scenarios.

Q3:"Can you provide more measurement concerning the walltime and peak memory (larger models)?"

A3. Measured so far (end-to-end calibration):

Setting GPTQ CMPQ Δ
Qwen3-8B-Base, 3-bit, single A40 49 min 70 min +43%

Analytically, CMPQ's calibration-time additions are:

  • one din×dind_{\mathrm{in}} \times d_{\mathrm{in}} fp32 accumulator for VV
  • one din×Nd_{\mathrm{in}} \times N activation buffer for ΔX\Delta X;
  • one extra full-precision forward pass per block.

The O(din3)O(d_{\mathrm{in}}^3) Cholesky that dominates GPTQ's cost is unchanged.

Authors · CommentOpenReview ↗

Q4: "Why does the GPTAQ surpass CMPQ on 14B model? Does it happen on larger models? Why the lower perplexity doesn't correlate in this case with higher accuracy? Could you provide results on broader range of model sizes and architectures to strengthen the claim and make sure the results are not cherry-picked and are reproducible outside small qwen models? The needs to be some empirical justification for assuming ξ\xi is zero-mean. Can you add some experiments supporting that?"

A4. This question bundles four separable concerns; we answer each in turn.

(a) Why does GPTAQ surpass CMPQ at 14B? Does it happen at larger sizes?

At 14B/2-bit the perplexity gap is WT2 14.44 (GPTAQ) vs 14.60 (CMPQ) , about 1.1% relative. While the zero-shot gap runs the other way by +3.18 points in CMPQ's favour, with CMPQ winning all six zero-shot tasks individually. So this is a marginal perplexity difference alongside a substantial accuracy difference, not two metrics disagreeing about a large effect.

(b) Why doesn't lower perplexity correlate with higher accuracy here?

At 2-bit both models are far from the BF16 reference that WikiText-2 perplexity saturates as a proxy: a heavily quantized model can retain fluent local token statistics, while losing the discriminative structure the zero-shot tasks probe. The 14B/2-bit cell is exactly this regime (0.16 perplexity vs 3.18 accuracy points, in opposite directions).

(c) Broader range of model sizes and architectures

See A1.

(d) Empirical justification for the zero-mean assumption

See A2.

Authors · CommentOpenReview ↗

Thank you again for your constructive review. In our rebuttal, we provided additional results on LLaMA-2-13B, Qwen2.5-7B, and Mistral-Nemo-12B, empirical layer-wise evidence regarding the zero-mean assumption, calibration-time measurements, and further clarification of the Qwen3-14B results. As the discussion period is about to close, we wanted to kindly ask whether these additions address your main concerns. We would greatly appreciate any final feedback and would be happy to clarify any remaining concerns.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…