potentialpaper

CORTEG: Foundation Models Enable Cross-Modality Representation Transfer from Scalp to Intracranial Brain Recordings

Liuyin Yang, Qiang Sun, Bob Van Dyck, Eva Calvo Merino, Marc M. Van Hulle

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. CORTEG provides the first evidence that scalp-EEG foundation models can transfer to intracranial ECoG, achieving state-of-the-art decoding with minimal patient-specific adaptation.

Abstract. Intracranial electrocorticography (ECoG) offers high–signal-to-noise access to cortical activity for brain–computer interfaces, yet limited per-patient data has led most prior work to rely on small, subject-specific decoders that neglect information shared across patients. We investigate whether large pretrained scalp-EEG foundation models (EEG FMs) can be adapted to ECoG, enabling cross-patient learning and competitive decoding performance while calibrating to a held-out patient in 1010--3030 minutes on a single GPU. We introduce \textbf{CORTEG}, a cross-modality transfer framework that combines a pretrained EEG FM backbone, an electrode-aware KNNSoftFourier spatial adapter, a dual-stream tokenizer for low-frequency and high-gamma activity, and a leave-one-subject-out fine-tuning strategy. We evaluate CORTEG on two challenging regression tasks: public finger-trajectory regression (n=9n=9) and private audio-envelope regression (n=16n=16). CORTEG achieves state-of-the-art mean performance on both tasks, achieving the highest mean correlation among the compared methods on the public finger benchmark and larger, statistically significant gains on the audio task and in low-data-per-patient calibration. We further validate CORTEG on the public BrainTreebank stereo-EEG classification tasks, where it also performs strongly. Furthermore, CORTEG outperforms the compared intracranial-EEG foundation models across the continuous regression tasks. Feature analyses align with neurophysiology, and latent representations capture low-dimensional finger-movement structure. Together, these results provide systematic evidence that scalp-EEG pretraining can be repurposed across intracranial recording modalities and tasks, enabling data-efficient neural decoders that can adapt to new patients.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
4 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]—[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:43 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

Summary

This paper proposes CORTEG, a framework for adapting pretrained scalp-EEG foundation models (ST-EEGFormer) to intracranial ECoG decoding. The approach addresses modality gaps via: (1) a KNNSoftFourier spatial adapter mapping ECoG electrode coordinates into the EEG channel codebook, (2) a dual-stream tokenizer separating low-frequency and high-gamma activity, and (3) LoRA-based fine-tuning with a leave-one-subject-out (LOO-FT) strategy enabling rapid per-patient calibration. Evaluation on finger trajectory regression (public, n=9) and audio envelope regression (private, n=16) shows CORTEG achieves the highest mean correlation among compared methods, with statistically significant gains only on the audio task. Ablations reveal that the pretraining benefit is task-dependent — large for the audio task but modest for motor — raising questions about what fraction of performance stems from pretrained representations versus architectural innovations.

Strengths

  • Important and well-motivated problem. The paper addresses ECoG data scarcity and electrode variability — a genuine BCI deployment bottleneck (7Gx5: "critical bottleneck in ECoG BCIs"; NvGg: "first systematic study of scalp-EEG → ECoG transfer").
  • Well-designed spatial adapter. The KNNSoftFourier adapter provides a principled geometry bridge with Nadaraya-Watson initialization (7Gx5: "interpretable, principled way to interpolate"; NvGg: "well-justified by neuroanatomy").
  • Comprehensive and rigorous evaluation. 10+ baselines including ECoG-native task-specific models (DeepFingerNet, HiLoFuseNet), statistical testing, per-subject breakdowns, and thorough ablations (w24A: "attention to detail in the experimental setup"; 7Gx5: "leave-one-subject-out setup paired with thorough ablations").
  • Practical deployment contribution. LOO-FT achieves competitive performance with 10–30 minute calibration on a single GPU (NvGg). Neurophysiologically grounded analysis. Manifold analyses and electrode importance maps align with known neuroanatomy (w24A: "promising to see emergent properties reflecting biological priors").

Weaknesses

  • Core transfer claim weakly supported — non-significant on the public benchmark and reliant on private data for statistical significance. On the reproducible finger task, gains over the best baseline are non-significant, and the ablation reveals only a modest drop when removing pretraining, suggesting architecture and population training account for most performance (7Gx5: "architectural design...not EEG pretraining — account for much of the observed performance"; w24A: "large gap in the fundamental argument"). The statistically significant audio result, which provides the paper's strongest evidence, cannot be independently verified (7Gx5: "strongest evidence relies on a private audio dataset"; NvGg: "no anonymized assets or URL were provided").
  • No comparison with iEEG/ECoG foundation models. While the paper includes ECoG-native task-specific baselines and a from-scratch ablation (random init), it does not compare against existing intracranial foundation models. This comparison would directly test whether scalp-EEG FM transfer can compete with within-modality self-supervised pretraining on iEEG data (7Gx5: "absence of a competitive ECoG-only population model weakens external validity").
  • Dual-stream architecture incompletely ablated. No comparison against early fusion or no frequency separation, leaving late-fusion benefit unestablished (w24A: "ablations only show the benefit over HF and LF components alone, not the combination with early fusion or no separation"; NvGg: "the paper does not verify the design intuition").
  • Absence of scaling benefit undermines the foundation-model framing. Small, Base, and Large backbones perform equivalently (NvGg: "Does the lack of scaling indicate limited ECoG data, architectural mismatch...or that scalp-EEG pretraining does not scale cleanly to ECoG?").

What Would Change Acceptance Odds

This paper needs further clarification. To increase the odds toward acceptance, I suggest to prioritize these focus areas in the rebuttal: Compare against iEEG foundation models: The random-init ablation already shows the architecture trained from scratch on pooled ECoG. What remains unclear is how the proposed approach compares against existing iEEG FMs (e.g., Brant, BrainBERT). Validate on an additional public ECoG/iEEG dataset with the pretraining ablation: Since the statistically significant result relies on private data, demonstrating CORTEG on another publicly available ECoG dataset — and showing that EEG pretraining helps compared to random initialization on that dataset — would substantially strengthen the transfer claim on reproducible data.

Final justification

The authors were highly responsive, providing extensive new experiments directly addressing both prioritized questions from the initial meta-review. Reviewer engagement was asymmetric: w24A engaged deeply and raised their score from 3 to 5, championing acceptance; NvGg responded after a 6-day delay and raised from 3 to 4; 7Gx5 was unresponsive throughout the discussion period and is flagged accordingly.

Both critical rebuttal questions were satisfactorily addressed:

  • iEEG FM comparison: Brant, BrainBERT, and Population Transformer all performed below a simple ridge baseline on the paper's tasks, demonstrating that existing iEEG FMs do not transfer to continuous decoding — validating the cross-modality approach.
  • Additional public dataset with pretraining ablation: on BrainTreebank (public sEEG), CORTEG achieved 0.683 AUROC vs. 0.547 for random initialization, confirming pretraining benefit on reproducible data. CORTEG also outperformed all iEEG FMs on this benchmark.

Additionally, the REVE backbone ablation demonstrates framework generality beyond ST-EEGFormer.

The authors’ excellent rebuttal resolves the primary weaknesses identified in the initial meta-review. The paper now demonstrates that EEG FM transfer to ECoG/iEEG (a) outperforms domain-specific FMs, (b) benefits from pretraining on an additional public dataset, and (c) generalizes across FM backbones. Combined with the thorough evaluation, practical LOO-FT contribution, and honest reporting, the paper merits acceptance, conditioned on incorporating the new results in the final manuscript.

Area Chair PXsu · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

Summary

This paper proposes CORTEG, a framework for adapting pretrained scalp-EEG foundation models (ST-EEGFormer) to intracranial ECoG decoding. The approach addresses modality gaps via: (1) a KNNSoftFourier spatial adapter mapping ECoG electrode coordinates into the EEG channel codebook, (2) a dual-stream tokenizer separating low-frequency and high-gamma activity, and (3) LoRA-based fine-tuning with a leave-one-subject-out (LOO-FT) strategy enabling rapid per-patient calibration. Evaluation on finger trajectory regression (public, n=9) and audio envelope regression (private, n=16) shows CORTEG achieves the highest mean correlation among compared methods, with statistically significant gains only on the audio task. Ablations reveal that the pretraining benefit is task-dependent — large for the audio task but modest for motor — raising questions about what fraction of performance stems from pretrained representations versus architectural innovations.

Strengths

  • Important and well-motivated problem. The paper addresses ECoG data scarcity and electrode variability — a genuine BCI deployment bottleneck (7Gx5: "critical bottleneck in ECoG BCIs"; NvGg: "first systematic study of scalp-EEG → ECoG transfer").
  • Well-designed spatial adapter. The KNNSoftFourier adapter provides a principled geometry bridge with Nadaraya-Watson initialization (7Gx5: "interpretable, principled way to interpolate"; NvGg: "well-justified by neuroanatomy").
  • Comprehensive and rigorous evaluation. 10+ baselines including ECoG-native task-specific models (DeepFingerNet, HiLoFuseNet), statistical testing, per-subject breakdowns, and thorough ablations (w24A: "attention to detail in the experimental setup"; 7Gx5: "leave-one-subject-out setup paired with thorough ablations").
  • Practical deployment contribution. LOO-FT achieves competitive performance with 10–30 minute calibration on a single GPU (NvGg). Neurophysiologically grounded analysis. Manifold analyses and electrode importance maps align with known neuroanatomy (w24A: "promising to see emergent properties reflecting biological priors").

Weaknesses

  • Core transfer claim weakly supported — non-significant on the public benchmark and reliant on private data for statistical significance. On the reproducible finger task, gains over the best baseline are non-significant, and the ablation reveals only a modest drop when removing pretraining, suggesting architecture and population training account for most performance (7Gx5: "architectural design...not EEG pretraining — account for much of the observed performance"; w24A: "large gap in the fundamental argument"). The statistically significant audio result, which provides the paper's strongest evidence, cannot be independently verified (7Gx5: "strongest evidence relies on a private audio dataset"; NvGg: "no anonymized assets or URL were provided").
  • No comparison with iEEG/ECoG foundation models. While the paper includes ECoG-native task-specific baselines and a from-scratch ablation (random init), it does not compare against existing intracranial foundation models. This comparison would directly test whether scalp-EEG FM transfer can compete with within-modality self-supervised pretraining on iEEG data (7Gx5: "absence of a competitive ECoG-only population model weakens external validity").
  • Dual-stream architecture incompletely ablated. No comparison against early fusion or no frequency separation, leaving late-fusion benefit unestablished (w24A: "ablations only show the benefit over HF and LF components alone, not the combination with early fusion or no separation"; NvGg: "the paper does not verify the design intuition").
  • Absence of scaling benefit undermines the foundation-model framing. Small, Base, and Large backbones perform equivalently (NvGg: "Does the lack of scaling indicate limited ECoG data, architectural mismatch...or that scalp-EEG pretraining does not scale cleanly to ECoG?").

What Would Change Acceptance Odds

This paper needs further clarification. To increase the odds toward acceptance, I suggest to prioritize these focus areas in the rebuttal: Compare against iEEG foundation models: The random-init ablation already shows the architecture trained from scratch on pooled ECoG. What remains unclear is how the proposed approach compares against existing iEEG FMs (e.g., Brant, BrainBERT). Validate on an additional public ECoG/iEEG dataset with the pretraining ablation: Since the statistically significant result relies on private data, demonstrating CORTEG on another publicly available ECoG dataset — and showing that EEG pretraining helps compared to random initialization on that dataset — would substantially strengthen the transfer claim on reproducible data.

Final justification

The authors were highly responsive, providing extensive new experiments directly addressing both prioritized questions from the initial meta-review. Reviewer engagement was asymmetric: w24A engaged deeply and raised their score from 3 to 5, championing acceptance; NvGg responded after a 6-day delay and raised from 3 to 4; 7Gx5 was unresponsive throughout the discussion period and is flagged accordingly.

Both critical rebuttal questions were satisfactorily addressed:

  • iEEG FM comparison: Brant, BrainBERT, and Population Transformer all performed below a simple ridge baseline on the paper's tasks, demonstrating that existing iEEG FMs do not transfer to continuous decoding — validating the cross-modality approach.
  • Additional public dataset with pretraining ablation: on BrainTreebank (public sEEG), CORTEG achieved 0.683 AUROC vs. 0.547 for random initialization, confirming pretraining benefit on reproducible data. CORTEG also outperformed all iEEG FMs on this benchmark.

Additionally, the REVE backbone ablation demonstrates framework generality beyond ST-EEGFormer.

The authors’ excellent rebuttal resolves the primary weaknesses identified in the initial meta-review. The paper now demonstrates that EEG FM transfer to ECoG/iEEG (a) outperforms domain-specific FMs, (b) benefits from pretraining on an additional public dataset, and (c) generalizes across FM backbones. Combined with the thorough evaluation, practical LOO-FT contribution, and honest reporting, the paper merits acceptance, conditioned on incorporating the new results in the final manuscript.

3 comments
Authors · CommentOpenReview ↗

# Letter to the Area Chair — Submission 27804 (CORTEG)

Letter to the Area Chair — Submission 27804 (CORTEG) [part 1]

First, we thank the reviewers and AC for their time and constructive feedback, which helped us substantially strengthen the paper. The meta-review highlights two central priorities: comparison with intracranial foundation models and validation on an additional public dataset. We addressed both through extensive new experiments. Although we regret that no further reviewer responses were posted to discuss this evidence, we use this final statement to summarize the main findings and their implications for the paper.

New evidence

A. Comparison with intracranial foundation models

We first benchmarked BrainBERT, PopT, and Brant on our finger-trajectory and auditory-envelope regression tasks. As shown in Table 1, all three intracranial foundation models underperform a simple high-gamma ridge baseline, revealing a clear gap in adapting current intracranial foundation models to challenging continuous ECoG regression.

Table 1: within-modality comparison results, across evaluation splits (mean Pearson r)

Splits: pop = pooled/population, p-s = per-subject, LOSO = leave-one-subject-out (for CORTEG: pooled / per-subject / LOO-FT). The frozen-probe rows and CORTEG cover all three splits.

Model (~total trainable) Adaptation (trainable) Finger · pop · p-s · LOSO Audio · pop · p-s · LOSO
BrainBERT (~43 M) frozen probe (~3.8 K head) 0.030 0.039 0.044 0.031 0.052 0.050
PopT (~20 M) frozen probe (~2.6 K head) 0.040 0.049 0.050 0.031 0.038 0.039
CORTEG (ours) (~33 M) LoRA + adapter (297 K) 0.554 0.539 0.551 0.339 0.250 0.331
Raw-HGA baseline ridge / linear 0.336 0.175

Bigger models and more adaptation do not close the gap. Brant (~506 M, frozen, ~10 K linear head, native 6 s context) reaches only 0.028 / 0.022; and for BrainBERT / PopT, full fine-tuning (finger 0.040 / 0.053), a trained BiLSTM temporal head (0.053 / 0.063), and end-to-end last-N fine-tuning (collapses to ≤0.012) all stay ≤0.063 on finger and ≤0.057 on audio — below even the raw-HGA ridge.

B. Validation on the BrainTreebank sEEG classification task

To verify our approach's generalization, we evaluated CORTEG against three pretrained intracranial foundation models on the 10-subject BrainTreebank sentence-onset classification task.

Model AUROC
CORTEG 0.683
PopT 0.605
BrainBERT 0.565
Brant 0.519
CORTEG, random initialization 0.547
HiLoFuseNet 0.566
CNN_LSTM 0.526
Raw band-power ridge 0.535

These results show that CORTEG generalizes beyond the original ECoG regression setting to sEEG classification, while maintaining strong performance across different intracranial modalities and task formulations. Under the evaluated protocols, all three iEEG-pretrained models perform worse than CORTEG, further supporting the effectiveness of transferring a scalp-EEG foundation model through the proposed framework.

Authors · CommentOpenReview ↗

# Letter to the Area Chair — Submission 27804 (CORTEG)

Letter to the Area Chair — Submission 27804 (CORTEG) [part 2]

C. Dual stream fusion and backbone model choice

(1) Early fusion ablation was in our submission manuscript: Appendix Table9. Since we believe the choice of K is a hyperparameter, we provided our sweep in the appendix. Now, we additionally evaluated a layer-wise gated fusion variant CORTEG that learns the fusion at each layer and therefore avoids a separate manual sweep over K. As shown in Table 2, the gated model can perform as good as the original CORTEG.

Table 2. Layer-wise gated fusion compared with fixed-KK mean-pooling.

Task Model size Mean-pool rr Gated rr (Delta r) Adjusted pp Subjects improved Note
Finger Small 0.5724 0.5747 +0.002 0.73 — No meaningful change
Finger Base 0.5732 0.5915 +0.018 0.008 8/9 Significant improvement
Finger Large 0.5691 0.5789 +0.010 0.08 — No meaningful change
Audio Small 0.3366 0.3220 −0.015 0.013 3/16 Significant degradation
Audio Base 0.2372 0.2814 +0.044 <0.001 15/16 Significant improvement
Audio Large 0.1940 0.3228 +0.129 <0.001 16/16 Significant improvement

(2) To address the reviewer's concern about the EEG foundation model choice, and test if CORTEG highly depends on ST-EEGFormer, we repeated the full pipeline with REVE, another strong EEG FM. As shown in Table 3, REVE performs much better than CBraMod and LaBram. The dual-stream fusion strategy remains the strongest. These results show that CORTEG is not specific to ST-EEGFormer, while also indicating that effective transfer requires backbone-specific optimization and task-relevant feature design.

Table 3. CORTEG with REVE as the backbone model.

Stream Finger (r) Audio (r)
Dual-stream CORTEG 0.529 0.293
High-gamma only 0.514 0.190
Low-frequency only 0.353 0.288
ST-EEGFormer CORTEG, submitted 0.554 0.339
Ridge on raw high-gamma 0.336 0.175

Camera-ready revisions

The camera-ready version will incorporate the main findings from the rebuttal:

  • Add comparisons with intracranial foundation models. BrainBERT, PopT, and Brant results will be added to the original finger and audio tasks and on BrainTreebank, clarifying how scalp-to-intracranial transfer compares with within-modality pretraining.
  • Add public BrainTreebank validation. The new sEEG sentence-onset experiment will provide additional evidence that CORTEG generalizes across intracranial modalities and from regression to classification.
  • Extend the backbone ablation with REVE. This experiment will show that the framework is not specific to ST-EEGFormer, while emphasizing the need for backbone-specific adaptation.
  • Clarify the dual-stream interpretation. We will highlight the task-dependent roles of the two streams: high-gamma is most important for finger decoding, whereas low-frequency representations dominate auditory envelope decoding. Early/late fusion, no-separation, and gated-fusion results will also be included.
Authors · CommentOpenReview ↗

# Letter to the Area Chair — Submission 27804 (CORTEG)

Letter to the Area Chair — Submission 27804 (CORTEG) [part 3]

Why we believe this paper should be considered

1. It establishes a new research direction. To our knowledge, this is the first systematic study of transferring scalp-EEG foundation models to intracranial decoding across multiple datasets, modalities, and task types, with comparisons against task-specific ECoG models, random initialization, alternative scalp-EEG backbones, and three intracranial foundation models. The results open several concrete research directions, including improved backbone selection, adaptive fusion, task-specific feature streams, and analysis of which pretrained representations transfer across modalities.

2. It demonstrates that large pretrained models can be competitive on challenging continuous ECoG regression tasks. Continuous finger-trajectory and auditory-envelope decoding have long been dominated by compact, participant-specific models. CORTEG reaches the strongest mean performance on both tasks while reusing a pretrained cross-subject representation. The additional BrainTreebank results further show that the framework generalizes from ECoG regression to sEEG classification and that pretrained initialization provides a substantial advantage over the same architecture trained from scratch.

3. It provides evidence that cross-subject data scaling matters for intracranial decoding. Across the evaluated datasets, pooled training improves the decoding performance. This suggests that assembling larger and more diverse intracranial datasets may be at least as important as increasing model size, which is an important but comparatively understudied direction in ECoG and sEEG research.

4. It provides a geometry-aware solution for heterogeneous ECoG recordings. ECoG electrode layouts vary substantially across patients because grids are implanted at different locations and with different geometries. CORTEG addresses this variability through a simple geometry-conditioned adapter that maps patient-specific electrode coordinates into a shared representation space. Our ablations show that this spatial adapter is critical to performance, providing an effective way to reuse cross-subject recordings despite heterogeneous electrode placement.

Taken together, we believe the paper provides both strong empirical results and a credible foundation for a new line of work on cross-modality foundation-model transfer for intracranial decoding.

Reviewer NvGgOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
2/4
Clarity
3/4
Significance
3/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper introduces CORTEG, a cross-modality transfer framework that adapts a pretrained scalp-EEG foundation model (ST-EEGFormer) to intracranial ECoG decoding. The approach rests on three contributions: (i) a KNNSoftFourier spatial adapter that maps ECoG electrode coordinates into the EEG channel embedding codebook, eliminating the need to retrain the model backbone; (ii) a dual-stream tokenizer that separates low-frequency (1–64 Hz) and high-gamma (70–200 Hz) signals so each can be encoded with modality-appropriate spectral resolution; and (iii) a two-stage LOO-FT deployment strategy that calibrates a new patient in 10–30 minutes on a single GPU. Together, these components address the central deployment bottleneck in intracranial BCI.

Strengths and weaknesses

Strength:

  1. Systematic study of an under-explored transfer problem. CORTEG is the first systematic study of scalp-EEG → ECoG transfer for a foundation-model-based decoder. The authors provide a rich set of baselines: per-subject decoders, population-trained from-scratch models, and ablations against alternative foundation-model backbones
  2. Well-motivated spatial adapter design. The KNNSoftFourier spatial adapter follows a clear domain-knowledge prior: ECoG electrodes near EEG electrodes should be encoded similarly. This inductive bias is well-justified by neuroanatomy and explains the model's behavior at initialization: the soft attention mass spreads over the spatially nearest EEG channels, then concentrates on a dominant channel after training.
  3. Mechanistic interpretability through manifold analysis. The manifold-alignment analysis provides a mechanistic account of why transfer works: the cross-modality representations occupy the same geometric structure after spatial adaptation.

Weakness:

  1. Transfer signal is task-dependent. The cross-modality pretraining benefit is large on the audio task but modest on the finger task. The discussion about why the audio modality benefits more from the scalp-EEG prior, and whether this reflects differences in signal structure is missing.
  2. Small datasets and long per-patient calibration limit clinical utility. The finger task uses n = 9 subjects and the audio task uses n = 16 subjects, with the audio dataset held privately by the authors. Even with LOO-FT reducing training to 10–30 minutes per patient, this is still long for clinical deployment.
  3. Limited reproducibility. No anonymized assets or URL were provided.
  4. channel in fig 4 for s8 position seems far away from cortex, is that correct?
Questions
  1. High-gamma stream design lacks justification. The dual-stream tokenizer separates LFS (1–64 Hz) and HGA (70–200 Hz) into independent token streams, but the paper does not verify the design intuition. Why averaged with the encoder-processed low-stream tokens?
  2. Task scope is narrow. ECoG decoding supports a wide range of clinically meaningful classification tasks — seizure detection, speech decoding, error-related potentials, motor imagery. The paper restricts evaluation to finger flexion regression and auditory envelope regression. Why is this aim for?
  3. The paper claims ST-EEGFormer is "uniquely well-suited" because of its channel codebook. A controlled experiment is needed: train ST-EEGFormer with a randomly-initialized channel codebook like table 2. Table 2 Random init (no pretrain) full-FT + adapter with what model backbone?
  4. Does the lack of scaling indicate limited ECoG data, architectural mismatch, over-regularized LoRA adaptation, or that scalp-EEG pretraining does not scale cleanly to ECoG?
Limitations

yes

Final justification

The rebuttal addresses my main concerns through the new comparisons with intracranial foundation models and the public BrainTreebank experiment, which provide stronger evidence for the proposed cross-modality transfer. These additions materially improve my assessment of the paper. However, I expect the new experiments to be fully incorporated into the final manuscript with complete methodological and statistical details. The authors should also release the code and configurations as stated and address the remaining limitations and clarifications raised during the review. Based on the rebuttal and these commitments, I have raised my score.

Formatting concerns

No anonymized assets or URL were provided.

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Response to Reviewer NvGg

Thank you for the careful review. We address each concern below.

Weakness 1 — Why is the transfer benefit task-dependent?

We agree that the original discussion did not sufficiently explain the difference between the two tasks. EEG pretraining provides little benefit for high-gamma-dominant finger decoding but a substantial benefit for low-frequency-dominant auditory decoding. A plausible explanation is that scalp-EEG pretraining better captures transferable low-frequency structure, whereas finger decoding depends more strongly on focal high-gamma activity. We will revise the paper to make this task-dependent interpretation explicit.

Thus, EEG pretraining should not be expected to improve every downstream task; its value depends on alignment between the pretrained representation and the target signal structure. CORTEG addresses this limitation through a dedicated high-gamma pathway alongside the pretrained low-frequency representation. On finger decoding, this design remains competitive with task-specific methods and achieves the highest mean performance.

Weakness 2 — Small datasets, private auditory data, and clinical calibration

We acknowledge the limited sample sizes of the original datasets and that the private auditory data limit independent verification. We therefore added a fully public BrainTreebank sEEG sentence-onset experiment. Under a matched three-seed comparison, EEG-pretrained CORTEG reaches 0.699 AUROC versus 0.595 for random initialization, improving all subjects (Wilcoxon p=0.0156). This does not replicate the original ECoG regression tasks, but provides reproducible evidence that the transfer benefit extends to another intracranial modality and task.

We also agree that CORTEG is not a zero-calibration clinical system. Stage 2 uses approximately 10–30 minutes of patient data and 10–30 minutes of adaptation on one RTX 5090; zero-shot performance remains weak. Its current advantage is parameter-efficient reuse of cross-subject data rather than immediate deployment. Reducing calibration requirements remains important future work.

Weakness 3 — Reproducibility

To address the reproducibility concern, we have prepared the implementation, configurations, preprocessing pipeline, and data-access statement for release upon acceptance. NeurIPS policy prevents us from including external URLs in the rebuttal, but if venue rules permit, we would also provide confidential access to an anonymized repository through an official channel during the rebuttal period.

Figure 4 — S8 electrode position

The original Stanford coordinate is valid and is used unchanged before spatial transformation. Subject 8 has a larger head relative to the displayed fsaverage template, so normalization and two-dimensional projection create a small apparent displacement outside the cortical boundary. This is a visualization artifact and does not affect the model input.

Question 1 — Justification of the high-gamma stream and fusion strategy

The design follows the signal structure of the task: the pretrained EEG representation is strongest at low frequencies [1], whereas high-gamma activity is particularly informative for finger decoding [2]. We therefore combine the pretrained low-frequency pathway with a dedicated high-gamma stream.

We evaluated multiple fusion depths and more complex alternatives, including unsuccessful variants reported in Appendix Table 10. Simple mean fusion was the strongest and most consistent, while remaining parameter-free and less prone to overfitting. We additionally evaluated layer-wise gated fusion, which improves Finger-Base and Audio-Base/Large but degrades Audio-Small. We therefore retain mean fusion as the default and report gated fusion as an optional alternative that avoids a separate depth sweep.

Question 2 — Why restrict the task scope to finger and auditory regression?

Our initial question was whether a pretrained scalp-EEG model could be adapted to continuous intracranial decoding. Finger-trajectory prediction is a challenging multidimensional regression task for which the best decoders remain compact and participant-specific. After obtaining strong finger results, we added auditory-envelope regression to test a different task. CORTEG performs well in both, suggesting that it is not restricted to only one task.

Now, we further added BrainTreebank sentence-onset classification using public sEEG data, where pretrained CORTEG again outperforms random initialization. Together, the finger, auditory, and BrainTreebank experiments provide an initial feasibility study across two intracranial modalities, regression and classification, and different signal characteristics. We do not claim comprehensive coverage, and we believe that broader evaluation remains future work.

We have now further extended the evaluation to the fully public BrainTreebank dataset, using a sentence-onset classification task with stereo-EEG recordings (another modality). CORTEG again showed a clear benefit from EEG-pretrained initialization, providing additional evidence that the approach can transfer across different intracranial modalities, task formulations, and signal characteristics.

To summarize, our aim is not to claim comprehensive coverage of intracranial decoding, which is too ambitious. However, we believe that the finger, auditory-envelope, and BrainTreebank experiments together provide an initial feasibility study showing that a pretrained scalp-EEG model can be adapted to multiple intracranial decoding settings. Broader validation across seizure detection, speech production, error-related potentials, motor imagery, and other tasks remains important future work.

Question 3 — Channel-codebook control and the random-initialized backbone

The reviewer is correct that describing ST-EEGFormer as “uniquely well-suited” based on its pretrained channel codebook was too strong. New controlled ablations show that the exact codebook vectors are not the main source of benefit:

real pretrained codebook   0.5666
shuffled codebook          0.5656  (-0.0010)
synthetic codebook         0.5640  (-0.0026)
naive MLP(xyz) adapter     0.5145  (-0.0521)
no adapter                 0.5291  (-0.0375)

The MAE-trained channel embeddings act as distinct tokens rather than carrying specific semantic channel information. At transfer time, our adapter supplies the geometric prior by using ECoG coordinates and known EEG locations to construct inputs through KNN interpolation.

Shuffling or synthesizing the codebook changes performance by at most 0.003, whereas replacing the geometry-conditioned adapter with an MLP or removing it reduces performance by 0.037–0.052. Randomizing or zeroing ECoG coordinates reduces performance by 0.075 and 0.318, respectively. On BrainTreebank, coordinate shuffling reduces AUROC to 0.508. These results support the importance of the geometry-conditioned interface rather than the exact pretrained codebook content. We will revise the claim accordingly.

For the second part of Q3, the Stanford “random initialization” control uses the same ST-EEGFormer-S architecture as the baseline Full CORTEG-S (LoRA + KNNSoftFourier adapter).

Question 4 — Interpretation of the scaling plateau

We share the reviewer’s interpretation that the observed plateau does not support a beneficial model-scaling trend. The plateau could reflect limited ECoG data, architectural mismatch, the LoRA budget, or weak alignment between scalp-EEG pretraining and the target task, and our current experiments cannot distinguish these explanations.

This question also remains open more broadly. On continuous finger decoding, the strongest existing methods are still compact, task- and participant-specific models, and our additional experiments show that current intracranial foundation models do not transfer competitively to this task under the evaluated protocols. More generally, recent EEG-foundation-model benchmarks report mixed scaling behavior, with larger pretrained models sometimes failing to outperform compact neural networks. Therefore, increasing backbone size alone should not be assumed to improve downstream performance [3-5].

Our results instead suggest that data scaling may be a more promising direction than model scaling in the current setting. Pooled cross-subject training consistently benefits performance, indicating that a larger and more diverse Stage-1 population dataset could improve generalization to new patients. However, we have not yet conducted a controlled study that independently varies pretraining-data volume, population-training data, model size, and adaptation capacity. We will therefore present the observed plateau as an unresolved limitation and treat data scaling as a promising hypothesis for future work.

References

[1]Sun, Qiang, et al. "Large EEG Foundation Model Learns Informative Low-Frequency Representations from Intracranial Brain Signals." 1st ICLR Workshop on Time Series in the Age of Large Models. 2026.
[2]Merino, Eva Calvo, A. Faes, and M. M. Van Hulle. "The role of distinct ECoG frequency features in decoding finger movement." Journal of Neural Engineering 20.6 (2023): 066014.
[3]Kontras, Konstantinos, et al. "NeuroAtlas: Benchmarking Foundation Models for Clinical EEG and Brain-Computer Interfaces." arXiv preprint arXiv:2605.14698 (2026).
[4]Xiong, Wei, et al. "EEG-FM-Bench: A Comprehensive Benchmark for the Systematic Evaluation and Diagnostic Analyses of EEG Foundation Models." Forty-third International Conference on Machine Learning.
[5]Liu, Dingkun, et al. "EEG Foundation Models: Progresses, Benchmarking, and Open Problems." arXiv preprint arXiv:2601.17883 (2026).

Reviewer NvGg · CommentOpenReview ↗

Thank you for the comprehensive rebuttal. The new comparisons with intracranial foundation models and the public BrainTreebank experiment address my main concerns. I will consider raising my score accordingly.

Authors · CommentOpenReview ↗

Response to reviewer NvGg

Dear Reviewer NvGg,

Thank you for your thoughtful reconsideration and for acknowledging the additional evidence. We appreciate your careful review and are pleased that the new comparisons with intracranial foundation models and the BrainTreebank evaluation have addressed your main concerns.

Best regards,

The Authors

Reviewer 7Gx5OpenReview ↗
Rating
4/6
Confidence
3/5
Quality
2/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper assesses whether pretrained scalp-EEG encoders can be effectively adapted for ECoG decoding. To this end, CORTEG couples a frozen ST-EEGFormer backbone with spatial coordinate adapters, dual-stream frequency tokenization, and LoRA tuning. Experiments on two regression tasks (finger trajectory, audio envelope) show superior or competitive average correlations over task-specific baselines, with clear gains in low-resource audio settings. Ablation and neuroanatomical analyses further corroborate the pretraining utility and feature plausibility.

Strengths and weaknesses

Strengths:

  1. The paper tackles a critical bottleneck in ECoG BCIs -- limited patient-specific data and non-standardized electrode layouts -- and frames the transfer from abundant scalp EEG as both scientifically compelling and practically urgent.
  2. Rather than an ad hoc patchwork, the framework logically orchestrates a frozen EEG encoder, a coordinate-based geometry bridge, a dedicated high-gamma stream, and constrained fine-tuning, directly aligning each component with the specific modality mismatch.
  3. The KNNSoftFourier adapter stands out as a well-motivated engineering contribution. Its Nadaraya-Watson style initialization offers an interpretable, principled way to interpolate pre-trained EEG codebooks onto novel ECoG layouts, avoiding opaque MLP mappings.
  4. Beyond standard benchmarks, the leave-one-subject-out setup paired with thorough ablations -- particularly the striking drop from 0.339 to 0.156 when pretraining is removed on the audio task -- substantively substantiates the transferability claim while providing valuable behavioral insights.

Weaknesses:

  1. The marginal, non-significant gains on the public finger task directly contradict the abstract’s strong transfer claim, requiring a substantially more cautious framing throughout the paper.
  2. The strongest evidence relies on a private audio dataset; baselines are not uniformly retrained, and the absence of a competitive ECoG-only population model weakens external validity.
  3. Ablations show random initialization trails the full model by just 0.044 on finger, implying that architectural design and pooled training -- not EEG pretraining -- account for much of the observed performance.
Questions

See Weaknesses.

Limitations

Yes

Formatting concerns

None

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

Response to Reviewer 7Gx5

Thank you for the careful review. We address each concern below.

Weakness 1 — Framing of the public finger-decoding result.

We agree that the public finger result should not be interpreted as establishing a statistically significant improvement over the strongest task-specific baselines. Our abstract already states that CORTEG achieves the highest mean correlation on this benchmark while explicitly noting that the gain is not statistically significant at n=9n=9. Thus, our intended claim is competitiveness and feasibility, rather than demonstrated superiority on the finger task.

We believe the novelty lies in the transfer setting. To our knowledge, this is the first systematic study showing that a large neural-signal model pretrained on scalp EEG can be adapted to continuous intracranial finger-trajectory decoding and reach performance comparable to state-of-the-art task-specific ECoG decoders. Continuous individual-finger regression is a challenging BCI task, and leading approaches have generally relied on specialized, participant- and task-specific architectures. CORTEG therefore establishes the feasibility of cross-modal foundation-model transfer on this setting.

This transfer formulation also offers a different data-efficiency pathway from training an independent decoder for every patient. CORTEG first learns a shared population model from recordings collected across subjects and then adapts only approximately 297K parameters to a new patient. We believe this provides a promising route for scaling intracranial decoding by allowing improvements in large, multi-subject scalp-EEG pretraining corpora and cross-subject intracranial datasets to benefit future patients, rather than treating each patient as an isolated learning problem.

Weakness 2 — External validity and comparison with intracranial foundation models.

We agree that the strongest continuous-regression evidence currently comes from a private auditory dataset, which limits independent verification. To address this concern, we added two complementary analyses: (1) a direct comparison with existing intracranial foundation models on our two continuous decoding tasks, and (2) an external validation on the fully public BrainTreebank sEEG dataset.

(1) Comparison with intracranial foundation models

We benchmarked BrainBERT [1], PopT [2], and Brant [3] under the adaptation settings supported by each model, including frozen probing, subject-specific and population training, temporal-head adaptation, and fine-tuning. Table 1 summarizes the main results.

Table 1: within-modality comparison results, across evaluation splits (mean Pearson r)

Splits: pop = pooled/population, p-s = per-subject, LOSO = leave-one-subject-out (for CORTEG: pooled / per-subject / LOO-FT). The frozen-probe rows and CORTEG cover all three splits.

Model (~total trainable) Adaptation (trainable) Finger · pop · p-s · LOSO Audio · pop · p-s · LOSO
BrainBERT (~43 M) frozen probe (~3.8 K head) 0.030 0.039 0.044 0.031 0.052 0.050
PopT (~20 M) frozen probe (~2.6 K head) 0.040 0.049 0.050 0.031 0.038 0.039
CORTEG (ours) (~33 M) LoRA + adapter (297 K) 0.554 0.539 0.551 0.339 0.250 0.331
Raw-HGA baseline ridge / linear 0.336 0.175

Bigger models and more adaptation do not close the gap. Brant (~506 M, frozen, ~10 K linear head, native 6 s context) reaches only 0.028 / 0.022; and for BrainBERT / PopT, full fine-tuning (finger 0.040 / 0.053), a trained BiLSTM temporal head (0.053 / 0.063), and end-to-end last-N fine-tuning (collapses to ≤0.012) all stay ≤0.063 on finger and ≤0.057 on audio — below even the raw-HGA ridge.

These results indicate that existing intracranial-FM representations do not transfer competitively to continuous finger-trajectory or speech-envelope regression. We interpret this as a task-specific representation and adaptation gap.

(2) Public BrainTreebank validation

To test whether the benefit of EEG pretraining generalizes beyond the private auditory dataset, we applied CORTEG to sentence-onset classification on BrainTreebank [4], a fully public stereo-EEG dataset. BrainTreebank differs from our original tasks in both recording modality and task type: it uses depth sEEG and sentence-onset classification rather than surface-ECoG regression. It therefore provides an external test of the broader transfer strategy rather than a direct replication of the finger or auditory experiments.

(a) Matched CORTEG pretraining ablation

We first tested whether EEG foundation model backbone provides a measurable benefit under a matched adaptation protocol.

Table 2. BrainTreebank sentence-onset classification with CORTEG.

Model variant Trainable components AUROC
EEG-pretrained CORTEG LoRA-4 + adapter + head (297K) 0.699
Random-initialized CORTEG LoRA-4 + adapter + head (297K) 0.595
Shuffled electrode coordinates Negative control 0.508
No LoRA adaptation Negative control 0.494

The runs use the same data splits, preprocessing, training environment, model-selection procedure, and trainable-parameter budget; only the backbone initialization differs. Results are averaged over three seeds per model variant. EEG-pretrained initialization improves AUROC by +0.104 p=0.016p=0.016. This provides a matched and statistically supported demonstration that EEG-pretrained initialization benefits a fully public intracranial task.

(b) Intracranial-FM positive controls

We also evaluated frozen BrainBERT and PopT representations on the same dataset.

Table 3. Frozen intracranial-FM representations on BrainTreebank.

Representation Adaptation AUROC
BrainBERT Frozen backbone + linear head 0.613
PopT Frozen backbone + linear head 0.606
Raw-HGA features Ridge classifier 0.510

BrainBERT and PopT outperform the raw-HGA baseline on this related classification task. These results serve as positive controls rather than a complete adaptation benchmark: because of rebuttal-time compute constraints, we did not exhaustively fine-tune every intracranial FM on BrainTreebank. We therefore do not use Table 3 to claim that CORTEG universally outperforms these models. Instead, it shows that their representations are useful on an aligned intracranial classification task.

Together, these analyses address the external-validity concern in two complementary ways. The within-modality comparison shows that the evaluated intracranial FMs are not yet competitive on the continuous regression tasks studied here, while the fully public BrainTreebank experiment independently verifies that EEG-pretrained initialization can benefit a different intracranial modality and task.

Weakness 3 — Contribution of EEG pretraining.

We agree that the finger ablation indicates that the architecture and pooled cross-subject training account for much of CORTEG’s performance on this task. However, the submitted Table 2 comparison does not cleanly isolate the contribution of pretraining because CORTEG uses LoRA plus the adapter, whereas the random-initialized model is trained with full fine-tuning.

Our results suggest that the contribution of EEG pretraining is task-dependent. It is small on high-gamma-dominant finger decoding, but substantial on low-frequency-dominant auditory decoding and on the public BrainTreebank task. This can be explained by that auditory decoding relies more strongly on low-frequency structure that may be better represented by scalp-EEG pretraining, whereas finger decoding depends more heavily on focal high-gamma activity. We will revise the paper to make this task-dependent attribution explicit.

Taken together, our results do not suggest that EEG pretraining guarantees a performance improvement on every downstream task. Rather, its benefit depends on the alignment between the pretrained representation and the target signal structure. CORTEG’s dual-stream design was introduced to address this limitation by preserving a dedicated high-gamma pathway alongside the pretrained low-frequency representation. On finger decoding, this allows the transferred model to remain competitive with state-of-the-art task-specific methods and achieve the highest mean performance.

We're happy to clarify any of these during the discussion period.

References

[1]Wang, Christopher, Vighnesh Subramaniam, Adam Uri Yaari, Gabriel Kreiman, Boris Katz, Ignacio Cases, and Andrei Barbu. "BrainBERT: Self-supervised representation learning for intracranial recordings." arXiv preprint arXiv:2302.14367 (2023).
[2]Chau, Geeling, Christopher Wang, Sabera Talukder, Vighnesh Subramaniam, Saraswati Soedarmadji, Yisong Yue, Boris Katz, and Andrei Barbu. "Population transformer: Learning population-level representations of neural activity." ArXiv (2025): arXiv-2406.
[3]Zhang, Daoze, Zhizhang Yuan, Yang Yang, Junru Chen, Jingjing Wang, and Yafeng Li. "Brant: Foundation model for intracranial neural signal." Advances in Neural Information Processing Systems 36 (2023): 26304-26321.
[4]Wang, Christopher, et al. "Brain treebank: Large-scale intracranial recordings from naturalistic language stimuli." arXiv preprint arXiv:2411.08343 (2024).

Reviewer w24AOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper introduces CORTEG, a framework for transferring representations from EEG foundation models to intracranial ECoG. The idea is to essentially coerce ECoG signals such that they can be effectively ingested by an EEG foundation model, namely ST-EEGFormer. This involves two primary steps: (1) projecting the ECoG contacts' MNI coordinates onto the EEG spatial embedding space via a KNNSoftFourier adapter, and (2) decomposing the ECoG signal into low- and high-frequency bands, and employing a late-fusion strategy of the high-frequency information so the low-frequency information can be effectively processed by the EEG FM and then combined with the high-frequency via LoRA adapters. They also introduce a leave-one-subject-out finetuning strategy for adapting to new subjects downstream. Results on benchmarks, including finger trajectory and audio envelope regression, suggest that CORTEG enables cross-modal transfer on the downstream tasks and performance matching or surpassing single-subject baselines. Analysis of the learned representations also shows that the embedding space is organized meaningfully by fingers in the trajectories dataset.

Strengths and weaknesses

The paper demonstrates strong results showcasing the ability to transfer representations from pretrained EEG foundation models to ECoG with careful adaptation. I appreciate the attention to detail in the experimental setup to ensure fair benchmarking, and the ablation study is helpful to understand the contribution of individual components of the framework. Furthermore, it's promising to see emergent properties in the learned representations that reflect underlying biological priors. However, one major concern I have is the premise of transfer considering there was no comparison made with state-of-the-art decoders for intracranial EEG or ECoG [1,2,3]. To me, the idea of transfer being beneficial is when the modality we're transferring from has some clear strengths in foundation modeling, either from data availability or modeling perspectives. But neither seem to be the case for me, since it's not that we have a shortage of publicly available large-scale ECoG data per-se [4,5]. One could argue that EEG data is more plentiful and possibly better curated, but then the more convincing comparison would be an iEEG pretrained model versus an EEG FM-transferred model. To me, this is a large gap in the fundamental argument of the paper. Even taking existing EEG foundation model architectures/training schemes and pretraining them on iEEG would serve as a reasonable, and possibly even more controlled, comparison. I would be willing to increase my score if the authors are able to sufficiently address this concern.

In addition, while most of the components are properly ablated, I'm not fully convinced of the benefit of the dual-stream architecture. The motivation is compelling and I wouldn't be surprised to find it is helpful, but as far as I can tell the ablations only show the benefit over HF and LF components alone, not the combination with early fusion (or even no separation at all). Unless I'm missing it somewhere, I would request the authors to conduct this ablation study since the dual-stream architecture happens to represent a large part of their innovation.

[1] Zhang, Daoze, Zhizhang Yuan, Yang Yang, Junru Chen, Jingjing Wang, and Yafeng Li. "Brant: Foundation model for intracranial neural signal." Advances in Neural Information Processing Systems 36 (2023): 26304-26321.

[2] Wang, Christopher, Vighnesh Subramaniam, Adam Uri Yaari, Gabriel Kreiman, Boris Katz, Ignacio Cases, and Andrei Barbu. "BrainBERT: Self-supervised representation learning for intracranial recordings." arXiv preprint arXiv:2302.14367 (2023).

[3] Chau, Geeling, Christopher Wang, Sabera Talukder, Vighnesh Subramaniam, Saraswati Soedarmadji, Yisong Yue, Boris Katz, and Andrei Barbu. "Population transformer: Learning population-level representations of neural activity." ArXiv (2025): arXiv-2406.

[4] Peterson, Steven M., Satpreet H. Singh, Benjamin Dichter, Michael Scheid, Rajesh PN Rao, and Bingni W. Brunton. "Ajile12: Long-term naturalistic human intracranial neural recordings and pose." Scientific data 9, no. 1 (2022): 184.

[5] Mineault, Patrick, Niccolò Zanichelli, Joanne Zichen Peng, Anton Arkhipov, Eli Bingham, Julian Jara-Ettinger, Emily Mackevicius et al. "Neuroai for ai safety." arXiv preprint arXiv:2411.18526 (2024).

Questions

(Q1) I believe the dependence on ST-EEGFormer as the pretrained EEG model deserves some more attention or analysis. Presumably an effective cross-modal transfer framework would work well agnostic to the pretrained model it's transferring from, provided the pretrained model is sufficiently strong. Is it just that the other EEG FMs tested on are much weaker in comparison, based on similar EEG benchmarks? Could the authors try some more SOTA models like REVE [....] or ...?

(Q2) I’d like some clarification on the finetuning strategy. As far as I can tell, the setting is not that you have multiple downstream subjects you want to finetune on, but then what is NN referring to on line 128? What does “without retraining the population model” mean in this context, is it a statement about not having to do full finetuning or about data? Also, it’s mentioned that LOO-FT Stage-2 takes 10-30m; how about Stage 1?

(Q3) One noted strength was: “a population model can be trained once and efficiently adapted to new patients, instead of retraining a full per-subject decoder from scratch”. This is promising in principle but the argument would benefit from a more quantitative comparison of the tradeoffs of both approaches, e.g. in terms of compute requirements.

Limitations

Yes

Final justification

The authors have successfully addressed my initial concerns, and from the updated framing and my most recent perspective on the work, I believe this paper merits meaningful contributions to the field. I would champion its acceptance.

Formatting concerns

I believe the top margin is reduced on some pages (2, 5, 6, 7, 8) compared to the standard template. Not certain if this violates the formatting guidelines.

11 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Response to Reviewer w24A

Thank you for the careful review. We address each concern below.

Weakness1 — Motivation and clarification of the EEG-to-ECoG transfer. Our motivation for transferring an EEG foundation model to continuous ECoG finger-trajectory and auditory-envelope regression is based on three observations.

  1. Scalp EEG offers a substantially larger public-data resource than intracranial recordings. Aristimunha, et al. (2026) identified approximately 82,748 hours of publicly available EEG from 41,049 participants, compared with 33,840 hours of iEEG from 2,907 participants [1]. If cross-modal transfer is feasible, large and diverse EEG datasets could therefore provide useful pretrained representations for intracranial decoding, where data remain comparatively scarce and highly patient-specific.
  2. EEG foundation models have advanced rapidly, but their use has remained largely limited to scalp-EEG tasks. Recent models explore diverse pretraining objectives and architectures, yet it remains unclear whether their learned representations can support intracranial decoding. We therefore ask a basic feasibility question: can a foundation model pretrained on scalp EEG be adapted effectively to ECoG? Demonstrating such transfer would broaden the utility of EEG foundation models and provide a complementary route to learning from limited intracranial data.
  3. Continuous decoding remains a frontier in implantable BCIs, with recent clinical advances relying largely on task- and participant-specific models. For example, Willsey et al. (2025) achieved high-performance finger control using a shallow feedforward network trained on a single participant with paralysis [2], while Littlejohn et al. (2025) used specialized RNNs for large-vocabulary speech synthesis in a person with severe paralysis [3]. Although pretrained models have enabled cross-subject and cross-species decoding (e.g., Ryoo et al., 2026) [4], their success remains confined to a single recording modality. To our knowledge, this is the first systematic demonstration that large models pretrained on scalp EEG can be transfered and perform competitively with conventional ECoG decoders. To our knowledge, large models pretrained on another neural modality have not previously been systematically shown to perform competitively on continuous finger-trajectory decoding.

Weakness 2 — Comparison with intracranial foundation models. We thank the reviewer for this suggestion and agree that a direct within-modality comparison makes the evaluation more complete. We have therefore benchmarked BrainBERT, PopT, and Brant under the adaptation settings supported by each model, including frozen probing, subject-specific and pooled training, temporal-head adaptation, and fine-tuning. The results are summarized below. On finger decoding, all three models remain below the paper’s simple high-gamma ridge baseline, and they also remain below CORTEG on both tasks. These results indicate that, under the evaluated protocols, existing intracranial foundation-model representations do not transfer competitively to continuous finger-trajectory or speech-envelope regression. We interpret this as evidence of a task-specific representation and adaptation gap, since current intracranial foundation models have been developed and evaluated mainly on clinical-event classification, seizure-related tasks, or other segment-level representation learning tasks. By contrast, scalp-EEG foundation models have been evaluated across a broader range of BCI tasks, including both classification and regression. In particular, ST-EEGFormer has been tested on hand movement classification [5] and shown the best regression performance on the 2025 EEG foundation challenge [6], which are more closely aligned with the neural representations required here.

Table 1: within-modality comparison results, across evaluation splits (mean Pearson r)

Splits: pop = pooled/population, p-s = per-subject, LOSO = leave-one-subject-out (for CORTEG: pooled / per-subject / LOO-FT). The frozen-probe rows and CORTEG cover all three splits.

Model (~total trainable) Adaptation (trainable) Finger · pop · p-s · LOSO Audio · pop · p-s · LOSO
BrainBERT (~43 M) frozen probe (~3.8 K head) 0.030 0.039 0.044 0.031 0.052 0.050
PopT (~20 M) frozen probe (~2.6 K head) 0.040 0.049 0.050 0.031 0.038 0.039
CORTEG (ours) (~33 M) LoRA + adapter (297 K) 0.554 0.539 0.551 0.339 0.250 0.331
Raw-HGA baseline ridge / linear 0.336 0.175

Bigger models and more adaptation do not close the gap. Brant (~506 M, frozen, ~10 K linear head, native 6 s context) reaches only 0.028 / 0.022; and for BrainBERT / PopT, full fine-tuning (finger 0.040 / 0.053), a trained BiLSTM temporal head (0.053 / 0.063), and end-to-end last-N fine-tuning (collapses to ≤0.012) all stay ≤0.063 on finger and ≤0.057 on audio — below even the raw-HGA ridge.

Weakness 3 — The benefit of the dual-stream architecture. The fusion-depth sweep in the manuscript (Appendix Table9) already shows that performance depends on where the high-gamma stream is fused. Late-to-middle fusion generally outperforms near-input fusion (e.g., Base K=2 r=0.583 → K=11 r=0.470). Because the fixed fusion depth K is effectively an architectural hyperparameter, we now additionally evaluated a layer-wise gated fusion variant that learns a soft HGA contribution at each Transformer layer and therefore avoids a separate manual sweep over K. As shown in Table 2, the gated model can match the strongest fixed-K configurations and improves FInger-Base and Audio-Base/Large. However, it degrades Audio-Small and is therefore not uniformly superior. We therefore retain fixed-K mean-pooling as the default and report gated fusion as an optional alternative that reduces manual tuning. As this is, to our knowledge, the first systematic investigation of fusion strategies for transferring a pretrained scalp-EEG model to ECoG decoding, further improvements in adaptive fusion remain an interesting direction for future work.

Table 2. Layer-wise gated fusion compared with fixed-KK mean-pooling.

Task Model size Mean-pool rr Gated rr (Delta r) Adjusted pp Subjects improved Note
Finger Small 0.5724 0.5747 +0.002 0.73 — No meaningful change
Finger Base 0.5732 0.5915 +0.018 0.008 8/9 Significant improvement
Finger Large 0.5691 0.5789 +0.010 0.08 — No meaningful change
Audio Small 0.3366 0.3220 −0.015 0.013 3/16 Significant degradation
Audio Base 0.2372 0.2814 +0.044 <0.001 15/16 Significant improvement
Audio Large 0.1940 0.3228 +0.129 <0.001 16/16 Significant improvement

Results are obtained from a 5-seed experiment. Adjusted pp denotes the Holm-adjusted subject-level paired-test value. Positive (Delta r) favors gated fusion.

Question 1 — The backbone choice. We did consider backbone dependence and, prior to submission, had already evaluated direct substitutions using LaBraM, CBraMod, and MantisV2. These experiments show that the current framework is not fully backbone-agnostic: naïvely replacing ST-EEGFormer with LaBraM, CBraMod, or MantisV2 reduces finger-decoding performance by 0.18–0.36. We therefore restrict our claim to the present ST-EEGFormer-based implementation.

Our goal in this paper is to establish the feasibility of transferring a pretrained scalp-EEG foundation model to intracranial decoding, rather than to exhaustively optimize every possible backbone–interface combination. The weaker results from direct substitution do not necessarily imply that these backbones are unsuitable; their representations and input structures may require backbone-specific adaptation rather than the same fusion strategy used for ST-EEGFormer. Extending the current fusion strategy to stronger or more recent models, such as REVE, and investigating which representations transfer and why are important directions for future work.

Question 2&3 — Clarification of the fine-tuning strategy and compute trade-off. In our notation, NN denotes the total number of subjects in the dataset. The two-stage procedure is evaluated under leave-one-subject-out (LOSO) validation to simulate adaptation to a newly enrolled patient. For each held-out subject, Stage 1 trains a population model once using the pooled data from the remaining N−1N-1 subjects. Stage 2 then initializes from this population model and adapts to the held-out subject.

By “without retraining the population model,” we mean that when a new patient arrives, their data do not need to be added to the pooled dataset followed by a complete rerun of Stage 1. Instead, the existing population model is reused and only the lightweight Stage-2 adaptation is performed for that patient.

In terms of compute, Stage 1 requires approximately 6–12 GPU-hours for the Base and Large variants used in the sweeps. The Small variant is faster (2 hours). Stage 2 takes approximately 10–30 minutes per patient on a single RTX 5090. By comparison, a from-scratch HiLoFuseNet can be trained in approximately 1–2 minutes per patient, so CORTEG is not faster in wall-clock adaptation time. Its advantage is instead the reuse of a shared cross-subject model, parameter-efficient adaptation (297K versus 334K–1.16M trainable parameters), and performance approaching pooled training while leveraging recordings from other subjects.

References

[Due to character limitations, this will be provided in another response as soon as possible.]

Authors · CommentOpenReview ↗

References

References

[1]Aristimunha, Bruno, et al. "EEGDash: An open-source platform for machine learning on public neurophysiological data." arXiv preprint arXiv:2606.16041 (2026).
[2]Willsey, Matthew S., et al. "A high-performance brain–computer interface for finger decoding and quadcopter game control in an individual with paralysis." Nature Medicine 31.1 (2025): 96-104.
[3]Littlejohn, Kaylo T., et al. "A streaming brain-to-voice neuroprosthesis to restore naturalistic communication." Nature neuroscience 28.4 (2025): 902-912.
[4]Ryoo, A. H. W., Krishna, N. H., Mao, X., Azabou, M., Dyer, E. L., Perich, M. G., & Lajoie, G. (2026). Generalizable, real-time neural decoding with hybrid state-space models. Advances in Neural Information Processing Systems, 38, 51764-51791.
[5]Yang, Liuyin, et al. "Are EEG foundation models worth it? comparative evaluation with traditional decoders in diverse BCI tasks." The Fourteenth International Conference on Learning Representations. 2026.
[6]Aristimunha, Bruno, et al. "Eeg foundation challenge: from cross-task to cross-subject eeg decoding." arXiv preprint arXiv:2506.19141 (2025).\

Authors · CommentOpenReview ↗

Additional ablation: REVE as a second EEG foundation model

Additional ablation: REVE as a second EEG foundation model

To address the reviewer's concern about the EEG foundation model choice, and test if CORTEG highly depends on ST-EEGFormer, we repeated the full pipeline with REVE using pooled training and LoRA-only adaptation (479K trainable parameters, seed 42).

Stream Finger (r) Audio (r)
Dual-stream CORTEG 0.529 0.293
High-gamma only 0.514 0.190
Low-frequency only 0.353 0.288
ST-EEGFormer CORTEG, submitted 0.554 0.339
Ridge on raw high-gamma 0.336 0.175

1. The transfer framework generalizes to a second scalp-EEG backbone. With REVE replacing ST-EEGFormer, CORTEG retains 95% of the submitted finger-decoding performance and 86% of the auditory-decoding performance, while outperforming the raw high-gamma ridge baseline on both tasks. Achieving this performance required two REVE-specific adjustments: matching its documented input-magnitude convention and using denser training windows. This result suggests that the framework is not tied to a single pretrained backbone, although effective transfer still requires adaptation choices that respect each model’s original input and training conventions.

2. The dual-stream configuration remains the strongest on both tasks. For REVE, the dual-stream model achieves the highest mean performance for both finger and auditory decoding. Its advantage over the stronger single stream is modest and not statistically significant: (+0.015) for finger decoding ((p=0.20)) and (+0.005) for auditory decoding ((p=0.32)). This is consistent with the similarly modest, non-significant dual-stream advantage observed with ST-EEGFormer. We therefore interpret the two-stream design as providing a small but consistent benefit that is task-dependent.

3. The contribution of high-gamma information is strongly task-dependent. For finger decoding, the high-gamma-only stream substantially outperforms the low-frequency-only stream ((0.514) versus (0.353); (Delta r=+0.162)), with improvements for all 9 subjects and an exact Wilcoxon (p=0.004). For auditory decoding, the ordering reverses: the low-frequency-only stream outperforms the high-gamma-only stream ((0.288) versus (0.190); (Delta r=+0.098)), with improvements for 13 of 16 subjects ((p=0.003)).

This phenomenon again supports our task-dependent interpretation: finger decoding relies more strongly on focal high-gamma activity, whereas auditory decoding benefits primarily from low-frequency structure that is more closely aligned with the representations learned during scalp-EEG pretraining.

We believe this additional ablation provides strong evidence that CORTEG’s transferability is not specific to ST-EEGFormer and extends to a second scalp-EEG foundation model. Further gains may come from improved backbone selection, model-specific optimization, and alternative feature engineering, including replacing the fixed high-gamma stream with more task-relevant features.

Comments on the paper

1 comment
Area Chair PXsu · CommentOpenReview ↗

Gentle Reminder that Author and Reviewer Discussion Period is Ending

Dear Reviewers and Authors of Submission #27804 ,

This is a quick reminder that the discussion period with authors is ending on August 3rd. If you are a reviewer and need any clarifications based on the authors' rebuttal, please reach out soon.

Your, AC

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…