Region-Normalized DPO for Medical Image Segmentation
Hamza Kalisch, Constantin Seibold, Jens Kleesiek, Ken Herrmann, Frederic Jonske
NeurIPS 2026
Abstract. Direct Preference Optimization (DPO) has recently been applied to medical image segmentation, where comparing candidate masks can require substantially less annotation effort than producing new dense pixel-level masks. This makes pairwise preferences an appealing source of supervision. However, existing studies largely derive preferences from ground-truth masks, leaving open whether DPO remains effective under the imperfect feedback available in practice. We study this question using controlled noisy judges and oracle preferences, finding that vanilla DPO can exhibit training instability under noisy feedback. Our analysis identifies a normalization mismatch in dense DPO, where candidate masks often differ only in localized regions, yet their preference margin is averaged over the full image. This attenuates the effective preference scale and couples update strength to disagreement-region size. We propose Region-Normalized DPO (RN-DPO), which normalizes the preference margin over the disagreement region, removing both effects. Across two medical segmentation benchmarks, multiple judge configurations, and two backbones, RN-DPO consistently improves mean Dice over vanilla DPO, with gains persisting under oracle preferences and improved training stability under weak judges. Complementary control experiments reveal that restoring the overall preference scale accounts for a substantial part of the improvement, while RN-DPO retains additional gains beyond global calibration, highlighting the value of pair-specific normalization.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:44 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The submission proposes a simple modification to Direct Preference Optimization (DPO) with an application to medical segmentation. The modification is to normalize the per-pixel log likelihood ratio by the size of a disagreement region in ranking as opposed to the entire domain. Reviewers were positive about its being a simple modification to an existing framework that seems to have positive effect, but had concerns about the depth of the presentation of the approach. Lacking a deeper mathematical motivation, one reviewer called the method heuristic, while Reviewer k1VA questions the relationship with standard DPO and a scaled step size. These concerns would be valuable to address during the rebuttal.
Final justification
At the end of the rebuttal period, reviewers felt that the submission is borderline, with 2/3 recommending weak acceptance, while one felt it was just below the line, but perhaps acceptable for a MICCAI style venue. There were two main concerns cited by essentially all reviewers in the final justification: (i) that the claims are phrased for medical imaging in general, while experiments are demonstrated for two settings, and (ii) the clarity of the motivation for the method vs. the actual setup. On the other hand, the method is demonstrated on two different imaging modalities, giving a boost of a couple of Dice points on one, while remaining competitive on the other, and the positive points from the initial reviews about it being a simple modification to an existing framework remain.
Read meta-review
Meta-review
The submission proposes a simple modification to Direct Preference Optimization (DPO) with an application to medical segmentation. The modification is to normalize the per-pixel log likelihood ratio by the size of a disagreement region in ranking as opposed to the entire domain. Reviewers were positive about its being a simple modification to an existing framework that seems to have positive effect, but had concerns about the depth of the presentation of the approach. Lacking a deeper mathematical motivation, one reviewer called the method heuristic, while Reviewer k1VA questions the relationship with standard DPO and a scaled step size. These concerns would be valuable to address during the rebuttal.
Final justification
At the end of the rebuttal period, reviewers felt that the submission is borderline, with 2/3 recommending weak acceptance, while one felt it was just below the line, but perhaps acceptable for a MICCAI style venue. There were two main concerns cited by essentially all reviewers in the final justification: (i) that the claims are phrased for medical imaging in general, while experiments are demonstrated for two settings, and (ii) the clarity of the motivation for the method vs. the actual setup. On the other hand, the method is demonstrated on two different imaging modalities, giving a boost of a couple of Dice points on one, while remaining competitive on the other, and the positive points from the initial reviews about it being a simple modification to an existing framework remain.
1 comment
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This manuscript addresses the challenge of reducing the reliance on dense pixel-wise annotations in medical image segmentation by utilizing inexpensive, automated quality-control (QC) signals (modeled as "noisy judges"). The authors investigate DPO within the domain of dense spatial outputs. Specifically, the paper focuses on fine-tuning a base segmenter using pairs of proposed masks ranked by an imperfect judge. The authors observe that standard DPO can amplify optimization instability and propagate errors when the judge's preferences are noisy. To mitigate this, they propose RN-DPO, which introduces a spatially aware weighting mechanism that normalizes preference gradients by the size of the disagreement region between the compared segmentations, seeking to stabilize preference updates and prevent a low-quality judge from driving harmful network updates. Evaluations are presented across two medical image segmentation datasets.
Strengths and weaknesses
Strengths
- Shifting from dense pixel-level annotations to weaker, automated preference signals is an industrially and clinically highly valuable paradigm for scaling up AI models.
- The proposed RN-DPO displays better empirical stability and peak segmentation performance compared to vanilla DPO when subjected to lower-quality or biased judging signals across the chosen evaluation subsets.
- The paper is almost well-written and well-motivated.
Weaknesses
- The novelty is somewhat incremental. The conceptual shift from DPO to RN-DPO relies essentially on scaling the loss function by a factor inversely proportional to the spatial area of disagreement. While intuitive, this contribution is mathematically straightforward and reads more like an empirical heuristic than a robustly formulated theoretical framework for robust alignment.
- The authors primarily contrast their method with standard DPO. However, the literature on learning from noisy annotations, weakly supervised medical image segmentation, and robust loss functions (e.g., Generalized Cross Entropy, Peer Loss, or Co-teaching applied to dense targets) is extensive. The manuscript fails to benchmark against modern robust optimization strategies that could similarly suppress noisy gradient updates.
- In medical deployment, automated QC signals possess highly structured biases. The paper's simulation or modeling of these noisy judges feels overly simplified or artificial, casting doubt on whether RN-DPO would remain stable under authentic, systematic clinical judge biases.
Questions
- Why is a linear normalization chosen over logarithmic or exponential scaling of the disagreement region?
- Why were robust segmentation formulations under noisy labels (such as Soft Dice with label smoothing, Generalized Cross-Entropy, or active robust learning frameworks) omitted from the baselines?
- The spatial disagreement area can be large due to a systematic global shift or due to a completely hallucinated organ/tumor. How does RN-DPO differentiate between these scenarios? If the normalization penalizes both equally based purely on pixel count, it may inadvertently desensitize the model to severe topological errors.
Limitations
The authors adequately acknowledge the restricted dataset scope and synthetic judge regime in the manuscript, but they do not discuss potential pitfalls of applying RN‑DPO to domains with high inter‑annotator disagreement or to tasks where segmentation masks are highly multimodal. Moreover, the authors need to include a constructive discussion on how region-normalization might cause the network to ignore large but crucial anatomical variations, and they should outline explicit failure modes where RN-DPO fails to correct a systematically biased judge.
Final justification
After carefully reviewing the authors' rebuttal, the AC's meta-review focus, and the discussions with other reviewers, I recommend maintaining my initial score. While the added oracle-preference experiments, hyperparameter sweeps, robust-DPO comparisons, alternative miners, SegFormer results, and judge ablations usefully resolve several empirical concerns and show that RN-DPO can outperform vanilla DPO even without judge noise, the core conceptual issue remains only partially addressed: RN-DPO is algebraically equivalent to a disagreement-dependent rescaling of the DPO margin (or pair-specific temperature), so the experiments demonstrate usefulness without establishing a sufficiently distinct methodological contribution beyond adaptive weighting or temperature calibration. Practical motivation is also still weakly validated, as most judges are controlled segmentation models rather than clinicians or true label-free QC systems, leaving the method untested under realistic human feedback or clinical errors. The empirical scope stays narrow (two small 2D medical datasets and related backbones) and relies on extensive regime-specific tuning of learning rates and beta, which undercuts claims of robustness. Finally, strong dense semi-supervised baselines remain competitive or superior in several settings, further clouding the practical advantage of the preference-only pipeline.
Formatting concerns
None.
2 comments
Rebuttal
Dear reviewer 3e3B,
thank you for highlighting the practical relevance of preference-based supervision, RN-DPO’s improved stability and performance under noisy judges, and the paper’s presentation. Reviewer 2Nod also highlighted the method’s simplicity and extensive controlled evaluation, while Reviewer k1VA commented positively on the clarity and breadth of the experiments.
W1/Q1 (Motivation and choice of normalisation.): The factor is not selected heuristically as an empirical linear scaling rule. For a preferred and rejected mask, pixels outside their disagreement region are identical and cancel exactly in the DPO margin. Consequently, .
Full-domain averaging therefore introduces an implicit pair-dependent inverse temperature .
RN-DPO simply averages the remaining evidence over its actual support , thereby removing this geometric factor. Logarithmic or exponential corrections would not follow from the cancellation argument and would instead introduce an additional nonlinear dependence on region size. We also evaluate an interpolation between full-domain and region normalisation (see response to Reviewer k1VA), for which full region normalisation achieves the best overall point estimates.
W2/Q2 (Robust dense objectives.): Our study focuses specifically on learning from preferences between candidate masks and isolates robustness within this supervision interface. Accordingly, we also evaluate IPO, Multi-DPO, rDPO, -DPO, and Dr.DPO, including several objectives designed to improve robustness to noisy or heterogeneous preferences, while holding the remaining preference-learning pipeline fixed. Robust segmentation methods such as GCE, Peer Loss, co-teaching, and label smoothing instead assume dense per-pixel supervision and therefore address a related but distinct learning setting. We agree that robust dense-label training provides useful complementary context and will clarify this distinction and expand the corresponding discussion. Our claim is specifically that RN-DPO corrects a structural bias in DPO when comparative feedback is the available supervision.
W2/Q2 (Structured errors and ambiguous preferences.): RN-DPO addresses only the geometric coupling between update strength and disagreement size; it does not determine which disagreement is anatomically plausible or clinically important. It therefore does not explicitly distinguish a global shift, a hallucinated structure, or a valid alternative segmentation from geometry alone. This distinction must be encoded by the judge or by an additional structured quality signal.
RN-DPO does not ignore large regions: all pixels in contribute to the regional average, but region size alone is no longer treated as a proxy for preference importance. Consequently, inconsistent or annotator-dependent rankings may arise in multimodal settings, and a systematically biased judge may cause RN-DPO to reinforce rather than correct erroneous preferences. We will add these as explicit failure modes and discuss annotator-conditioned preferences, abstention or filtering, and topology-, anatomy-, or uncertainty-aware weighting as complementary directions in the final version.
Additional comparison with robust dense supervision
Dear Reviewer 3e3B,
during the ongoing discussion period, we additionally evaluated a representative robust dense-supervision baseline to complement the preference-learning baselines reported in the paper and directly address this concern. We conduct this comparison in the weak-judge regime for each dataset and base-model setting. Under the same Stage-2 setup, the judge’s highest-ranked candidate is used as a dense pseudo-label, and the model is trained with GCE+Dice. We retain the same initial checkpoints, corresponding weak judges, proposal budget, training budget, and evaluation protocol as for RN-DPO. Thus, the proposal source and judge are matched, while the supervision interface changes from a ranked candidate pair to a dense pseudo-label.
We tune the learning rate over {, } and the GCE parameter q over {0.5, 0.7} using the validation set. The selected learning rate is for both datasets, with for JSRT and for ACDC.
| Dataset | Base model | Method | Dice | HD95 |
|---|---|---|---|---|
| JSRT | Weak | GCE+Dice pseudo-label supervision | ||
| RN-DPO | ||||
| Strong | GCE+Dice pseudo-label supervision | |||
| RN-DPO | ||||
| ACDC | Weak | GCE+Dice pseudo-label supervision | ||
| RN-DPO | ||||
| Strong | GCE+Dice pseudo-label supervision | |||
| RN-DPO |
Across all four evaluated weak-judge settings, RN-DPO achieves higher mean Dice and lower mean HD95 than the GCE+Dice pipeline. Accordingly, this experiment shows that RN-DPO retains an advantage over this robust dense alternative. We view this result as complementary evidence rather than an exhaustive claim of superiority over every robust segmentation method.
- Rating
- 4/6
- Confidence
- 5/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 4/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper focuses on the key issue at the boundary in the medical image segmentation task. The insight is clear and valid in improving DPO for the segmentation task, the proposed RNDPO normalize the likelihood ratio only over the disagreement area between candidate masks, which is reasonable. Experiments on JSRT and ACDC show consistent improvements over vanilla DPO and several robust variants.
Strengths and weaknesses
Strength: The paper identifies a clear and task specific limitation of applying DPO to dense medical image segmentation. The relationship between disagreement area, preference margin, and gradient strength is clearly derived, providing a solid motivation for the proposed region normalization. RNDPO is simple and does not introduce additional models or complex hyperparameters. Its effectiveness is supported by extensive controlled experiments involving different judge reliability levels, mining strategies, judge types, backbones, and oracle preferences. The oracle results are particularly useful, as they show that the improvement is not only due to robustness against noisy rankings. Weakness:
- RNDPO removes the dependence of update strength on disagreement area, but treats disagreement regions similarly after normalization. In medical segmentation, however, regions can differ substantially in anatomical context and segmentation difficulty; for example, lesion boundaries may become more ambiguous when invading adjacent tissues. Incorporating spatial structure, boundary uncertainty, or anatomical context into the region weighting may provide a more reliable preference signal than normalizing by region size alone.
- The main controlled judges are trained using an additional pixel labeled split. Although these labels are not directly used to train the segmenter, they still represent extra dense annotation effort. The practical annotation efficiency and comparison with semi supervised methods under a matched total labeling budget are therefore somewhat unclear.
- The experiments are still limited to two 2D medical datasets, and most preference signals are generated by model based judges. Although the SegFormer and alternative judge results are useful, it is still unclear whether RNDPO would remain effective for 3D volumes or under more complex real clinician feedback.
Questions
How does RN DPO behave when the disagreement region is extremely small or mainly contains uncertain boundary pixels? How should the additional pixel labeled budget used to train the judge be counted when comparing annotation efficiency with semi supervised methods?
Limitations
yes
Final justification
The rebuttal provides useful clarification and additional evidence for small disagreement regions, but the main limitations regarding annotation budget and broader clinical validation remain. I therefore maintain my Borderline Accept rating.
Formatting concerns
No major formatting conerns.
1 comment
Rebuttal
Dear reviewer 2Nod,
we thank you for your positive assessment of RN-DPO’s clear mathematical motivation, simplicity, and extensive controlled evaluation. Reviewer 3e3B also highlighted the practical relevance and improved stability of the method, while Reviewer k1VA described the experiments as genuinely extensive.
W1 (Accounting for anatomical context): RN-DPO addresses a specific geometric bias: the dependence of preference strength on disagreement-region size. It does not model whether individual pixels within the disagreement region are equally reliable or anatomically important. Boundary uncertainty, spatial structure, and anatomy-aware weighting are therefore complementary to region normalisation rather than alternatives to it, and we view their integration as an important direction for future work.
W2/Q2 (Additional label budget): We agree that, when the controlled learned judge is viewed as a newly trained component of the complete pipeline, its dense labels should be counted separately from the labels used to train the segmenter. We report both budgets transparently and do not claim superiority over SSL under a matched total dense-label budget. However, is not an annotation requirement of the RN-DPO objective; it is used here to instantiate judges with systematically varying reliability, allowing us to study preference optimisation under controlled weak and strong feedback.
In practical settings, comparative feedback may instead come from an existing quality-control model, ensemble or uncertainty signal, quality estimator, or direct clinician comparison, without necessarily requiring the collection of an additional pixel-annotated dataset. Our experiments are designed to isolate how dense preference optimisation behaves as the reliability of the available ranking source changes, rather than to compare end-to-end annotation efficiency against SSL.
W3 (Limitations): We agree. Our current experiments establish RN-DPO in controlled 2D settings across multiple datasets, backbones, judge constructions, and reliability levels, but they do not establish its effectiveness for 3D volumes or real clinician feedback. The formulation itself extends directly from pixels to voxels by defining over the volumetric domain, but empirical validation in these settings remains necessary. Both 3D segmentation and clinician-derived preferences are already acknowledged in the paper as limitations and identified as important directions for future work.
Q1 (Extremely small or boundary-dominated disagreement regions): For extremely small disagreement regions, we analysed first-epoch RN-DPO logs under ground-truth rankings and recomputed the corresponding full-domain margins on the same pairs. Among the of pairs with the smallest disagreement regions, the median disagreement fraction was on ACDC and on JSRT. Across all pairs, the Spearman association between disagreement fraction and absolute margin was strong under full-domain normalisation ( on ACDC and on JSRT), but near zero under regional normalisation ( and , respectively). Thus, RN-DPO prevents preference signals from being suppressed in proportion to disagreement-region size when the two masks differ on only a very small subset of pixels. We also found no indication that tiny disagreement regions produced abnormally large RN-DPO margins: the 95th percentile of their absolute margins was comparable to that of the remaining pairs ( on ACDC and on JSRT).
When the disagreement region mainly contains ambiguous boundary pixels, the update still depends on whether the judge ranks the pair correctly. RN-DPO cannot correct a systematically wrong ranking or infer anatomical importance from the region alone. Uncertainty-, boundary-, or anatomy-aware weighting would therefore be complementary extensions. Empirically, RN-DPO improves HD95, and its largest JSRT class-wise gains occur on challenging structures such as the clavicles and heart. This is consistent with local and boundary-sensitive refinements not being systematically suppressed. We will clarify this scope and failure mode.
- Rating
- 3/6
- Confidence
- 4/5
- Quality
- 2/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposes a variant of the original DPO algorithm, named RN-DPO, for medical image segmentation. The idea is that standard DPO averages the per-pixel log-likelihood ratio over the whole image (1/|Ω|), but candidate masks differ only on a small region R, so the effective margin is scaled by r = |R|/|Ω|. This couple's update strength to disagreement area. RN-DPO normalizes over R instead (1/|R|), removing the coupling. The idea is evaluated on chest x-ray and cardiac MRI datasets.
Strengths and weaknesses
The paper is easy to follow. The writing is coherent, and the experiments are genuinely extensive, but the core contribution is thinner than it presents, which I detail as follows:
-
My main point of concern is the motivation of using DPO for medical image segmentation. Looking at Table 1, results of RN-DPO are dominated by the SSL baselines. On JSRT weak-base/weak-judge, the best preference method (RN-DPO) reaches 74.1 Dice, while UniMatch (81.5), BCP (80.4), and RCP4CL (81.9), using the same labeled budget and the same unlabeled pool. The paper does explain but if consistency-regularization SSL is far better at the identical task without needing a judge or proposal machinery, the motivation for preference-based segmentation is not justified. What is the effect of this paradigm particularly for medical image segmentation?
-
From my understanding, RN-DPO is algebraically DPO with a per-pair temperature β/r. This is the dense-prediction analogue of SimPO/LN-DPO, which normalize the DPO reward by sequence length. The related-work section cites token-level DPO and SimPO but the novelty is not really clear here.
-
Since RN-DPO is algebraically DPO with a per-pair temperature β/r, it's unclear whether the gains come from the shape of the reweighting or just a larger effective step on the disagreement region. Tuning learning rate and β separately per method ( section 4.2) means effective scale is never held fixed. Can the authors do a scale-matched control experiment, for example sweep a normalizer 1/|R|^γ, γ∈{0, 0.5, 1}) and show |R|-normalization still wins?
-
As mentioned above, RN-DPO is more like a loss weighting or adaptive temperature correction, not a fully new DPO method. Therefore I am not sure if RN-DPO is really a broad normalization family, or just a reweighting.
-
Minor point but some writings slips that affect clarity, e.g, the abstract's "this bias even degrades performance even under oracle" (doubled "even").
Questions
My main questions are detailed on my review above, the most important ones are as follows:
-
Can the authors clarify on their novelty compared to methods that normalize the DPO reward by sequence length?
-
Can the authors clarify what their benefit is compared to SSL methods? I am not convinced why DPO is really needed for medical image segmentation.
Limitations
Yes.
Final justification
I thank the authors for their detailed response and the additional experiments. The rebuttal was thorough and addressed several of my earlier points well. That said, I still do not think the paper meets the bar for NeurIPS, for the following reasons.
First, the evaluation is too narrow for a paper that frames itself around medical image segmentation in general. For a claim at that level of generality, I would expect experiments across diverse modalities, CT, ultrasound, and others, not just chest X-ray and cardiac MRI. As it stands, the two benchmarks do not convince me that the method transfers across the range of settings the framing implies.
Second, there is a mismatch between the motivation and the actual setup. The paper motivates the noisy-feedback problem with clinician visual judgments and inter-rater variability, but in practice every judge is a weaker segmentation model. Those models produce errors that are systematic and correlated, which is not how clinician feedback behaves. So the central clinical motivation is not really tested by the experiments.
Third, the empirical study is the more substantial contribution here, and I appreciate that. But with only two relatively easy 2D datasets, the paper reads to me as a better fit for a MICCAI-style venue than for NeurIPS.
Formatting concerns
N/A.
2 comments
Rebuttal
Dear Reviewer k1VA,
we appreciate your positive assessment that the paper is easy to follow, coherently written, and supported by genuinely extensive experiments. Reviewer 3e3B also commented positively on the writing, while Reviewer 2Nod likewise highlighted the breadth of the evaluation. We address your raised points as follows.
W1/Q2 (Role of DPO relative to SSL): Our paper focuses on settings in which an existing segmenter receives comparative assessments of candidate masks, for example from automated quality-control systems or clinicians. We systematically study when such rankings can improve the model through preference fine-tuning and how DPO should process them for dense segmentation outputs.
The JSRT weak-base/weak-judge regime is deliberately included as a stress test of preference learning under low-reliability feedback. In this regime, specialised SSL methods indeed outperform RN-DPO, showing that unreliable comparative feedback is not a substitute for SSL when unlabeled images are available. With a strong judge, however, RN-DPO exceeds the reported SSL baselines in the same weak-base setting on JSRT. This shows that the utility of preference-based adaptation depends critically on feedback reliability.
Preference learning can also complement SSL. Starting from a BCP-trained segmenter, RN-DPO increases Dice from to with a weak judge and to with a strong judge. RN-DPO therefore provides a second-stage adaptation mechanism when comparative feedback is available, including on top of an SSL-trained model. We will make the role of feedback quality, the purpose of the weak-judge stress test, and the complementary SSL+RN-DPO setting clearer in the final version.
W2/Q1 (Distinction from sequence-normalised DPO methods): As follows directly from the analysis in Sec. 3.3, RN-DPO can indeed be algebraically re-expressed as vanilla DPO with a pair-dependent inverse temperature . This equivalence, however, is a consequence of the identified dense-normalisation bias rather than the starting point of the method. Vanilla dense DPO already induces the unintended schedule . Because the two masks agree outside , those pixels cancel from the pairwise likelihood ratio, yet full-domain averaging still dilutes the remaining signal by dividing it by . This couples both the margin and update strength to the disagreement area. RN-DPO removes this geometric dependence by averaging over the support on which the comparison is informative.
This is distinct from sequence-length-normalised methods such as SimPO, which normalise each output independently by its own length. In segmentation, all candidates have the same output size , so output-length normalisation recovers the same full-domain normalisation and cannot address pair-specific variation in disagreement support. RN-DPO instead uses the jointly defined support , which can vary substantially between pairs whose individual output dimensions are identical. The core contribution is therefore not output-length normalisation itself, but identifying the pairwise disagreement support as the appropriate normalisation domain for dense preference learning. We will make this distinction, and the interpretation of as the algebraic form of the correction rather than an arbitrary adaptive-temperature schedule, more explicit in the final paper.
W3 (Scale-matched controls): We thank the reviewer for raising this excellent point and for suggesting a scale-matched control experiment. To test whether RN-DPO’s gains arise merely from separate hyperparameter tuning or from a larger effective scale, we perform two complementary controls: (i) an endpoint-preserving interpolation that progressively removes the disagreement-area dependence under identical hyperparameters, and (ii) a mean effective-scale-matched vanilla-DPO baseline. For control (i), the suggested family does not recover vanilla DPO at , because it omits the full-domain normalisation by . We therefore use the endpoint-preserving interpolation .
This gives exact vanilla DPO at , partial attenuation at , and exact RN-DPO at . Using identical vanilla-DPO-selected , learning rate, optimiser, schedule, and folds throughout, performance improves monotonically across every reported metric on both datasets (Table 1): Dice increases 71.8 → 72.5 → 73.4 on JSRT and 73.0 → 74.2 → 75.0 on ACDC, with corresponding improvements in HD95. This demonstrates a consistent cross-dataset trend as the analytically identified support dependence is progressively reduced, without method-specific tuning.
| Dataset | Dice | HD95 | |
|---|---|---|---|
| JSRT | |||
| ACDC | |||
Table 1. Endpoint-preserving normalization interpolation.
Because increasing also increases the typical margin magnitude, this interpolation alone cannot separate average scale restoration from removal of pair-dependent weighting. We therefore construct a strong mean effective-scale-matched vanilla-DPO baseline using RN-DPO's learning rate and .
We estimate separately for each dataset and feedback regime in a calibration pass using proposals generated by the initial Stage-1 checkpoint. Table 2 shows that scale matching strengthens vanilla DPO, confirming that initial mean attenuation is an important component. RN-DPO nevertheless achieves higher mean Dice in all four comparisons: by +0.5 and +3.0 points on JSRT under weak and oracle rankings, respectively, and by +1.2 and +0.5 points on ACDC. RN-DPO also improves HD95 in three of four comparisons, while scale-matched DPO is slightly better on ACDC weak/weak HD95. Together, these results show that separate tuning and average effective scale do not fully explain RN-DPO's gains. Global scale matching still retains the residual pair-specific factor , whereas RN-DPO removes this dependence entirely. We will include both valuable control experiments and clarify this distinction in the camera-ready version.
| Dataset | Regime | Method | Dice | HD95 | |
|---|---|---|---|---|---|
| JSRT | Weak/weak | DPO | |||
| RN-DPO | |||||
| JSRT | Oracle | DPO | |||
| RN-DPO | |||||
| ACDC | Weak/weak | DPO | |||
| RN-DPO | |||||
| ACDC | Oracle | DPO | |||
| RN-DPO |
Table 2. Comparison with mean effective-scale-matched vanilla DPO.
W4 (Scope of RN-DPO): RN-DPO is an exact support-normalisation correction for dense DPO: it prevents small disagreement regions from being diluted by full-domain averaging and removes the unintended dependence of each pair’s influence on spatial extent. Its algebraic form can be expressed as pair-dependent weighting or temperature correction, but the core contribution is identifying and eliminating this structural bias rather than proposing a broad new preference-optimisation family.
Additional Details on the Scale Controls
Dear Reviewer k1VA,
For clarity, we elaborate on the experimental setup of the two complementary scale controls.
The endpoint-preserving interpolation is evaluated in the weak-base/weak-judge regime on both JSRT and ACDC and tests whether performance improves as disagreement-area dependence is progressively removed without method-specific retuning.
The mean-effective-scale-matched experiment tests whether RN-DPO’s gains persist when vanilla DPO is matched to the same average effective scale. For each pair mined in a calibration pass using proposals generated by the initial Stage-1 checkpoint, we compute and estimate separately for each dataset and feedback regime. We then compare:
- RN-DPO: learning rate , regional normalization , and ;
- scale-matched vanilla DPO: the same and training settings, global normalization , and
We use RN-DPO’s selected learning rate for both methods and set vanilla DPO’s to match RN-DPO’s average effective scale. For example, on JSRT weak/weak, and , yielding .
This matching is intentionally not exact at the individual-pair level. Vanilla DPO retains the residual factor , which is precisely the pair-dependent weighting under investigation. Exact pairwise matching would require , which is algebraically equivalent to RN-DPO itself and would therefore no longer constitute a distinct vanilla-DPO control.
As in the main paper, all scale-matched results reported here are averaged over three different partitions of the training data into labeled and unlabeled sets, rather than obtained by rerunning the same partition with different optimization seeds. RN-DPO achieves higher mean Dice in all four scale-matched comparisons reported in W3.
In W3, the oracle comparisons use the weak-base initialization and show particularly pronounced gains for RN-DPO on JSRT. To assess whether these oracle gains are robust to the starting point, we repeated the scale-matched oracle comparison from the strong-base initialization. On JSRT, RN-DPO improves Dice from to (+2.4 Dice) and reduces HD95 from to (-4.2 HD95). On ACDC, RN-DPO improves Dice from to (+1.3 Dice) and reduces HD95 from to (-1.0 HD95). The advantage therefore persists across both datasets and both metrics under oracle rankings, including from a substantially stronger initialization.
Together, these controls show that RN-DPO’s gains are not explained solely by separate hyperparameter tuning or a larger average effective scale. They support the paper’s central contribution: identifying a structural bias induced by disagreement-region size in DPO for segmentation and demonstrating that a simple yet principled correction yields consistent empirical gains.
Sincerely,
The Authors of Submission 27998
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Summary of the rebuttal
Dear Area Chair,
Before the discussion closes, we would like to briefly summarize how our rebuttal addresses the concerns prioritized in the initial meta-review and highlight the evidence supporting the paper’s central contribution.
1. Mathematical motivation and relation to standard DPO. In DPO for segmentation, the preferred and rejected masks differ only on their disagreement region R. Pixels outside R cancel exactly from the pairwise log-likelihood ratio, yet full-domain normalization still divides the remaining evidence by ∣Ω∣. This introduces an unintended dependence of both the preference margin and update strength on r=∣R∣/∣Ω∣. RN-DPO directly corrects this support mismatch by normalizing over the region R on which the comparison is informative. RN-DPO can therefore be represented algebraically as DPO with a pair-dependent weighting or temperature correction. However, this representation is a consequence of removing the factor induced by full-domain normalization, rather than the motivation for introducing an arbitrary or heuristic reweighting. This principled motivation is also supported by Reviewer 2Nod, who noted with high confidence that the “relationship between disagreement area, preference margin, and gradient strength is clearly derived, providing a solid motivation” for RN-DPO.
2. Relation to sequence normalization. Methods such as SimPO normalize the preferred and rejected outputs independently by their respective sequence lengths. In segmentation, both masks always have the same fixed H×W length, so this reduces to the same full-domain normalization for every pair and cannot account for where the masks actually differ. In contrast, RN-DPO normalizes by the jointly defined disagreement region R(y+,y−), whose size depends on the pair and can change even for the same mask when it is compared with a different candidate.
3. Are the gains explained only by tuning or effective scale? The initial meta-review asked whether RN-DPO’s improvements could be reproduced by standard DPO through different hyperparameter tuning or a larger effective update scale. We addressed this with two complementary controls. First, under the endpoint-preserving interpolation, performance improves monotonically on both JSRT and ACDC as disagreement-area dependence is progressively removed, while β, learning rate, optimizer, schedule, and labeled-data partitions remain fixed. This rules out method-specific retuning as the explanation. Second, we constructed a mean-effective-scale-matched vanilla-DPO baseline using RN-DPO’s selected learning rate and an analytically derived β that matches RN-DPO’s average effective scale. Although scale matching strengthens vanilla DPO, RN-DPO retains higher mean Dice in all four reported scale-matched comparisons in W3, including a 3.0-point Dice gain in the weak-base JSRT oracle setting. To test whether this oracle advantage was specific to the weak-base initialization, we additionally repeated the scale-matched oracle comparison from the strong-base initialization. RN-DPO again yields substantial improvements in both Dice and HD95 on both datasets.
Beyond these targeted analyses, RN-DPO is evaluated on two medical imaging datasets, different base-model strengths, judge strengths, judge types, oracle preferences, multiple backbones, and mining strategies, with consistent improvements across these settings. The extensive experimental evaluation was explicitly highlighted by Reviewers k1VA and 2Nod. Reviewers k1VA and 3e3B also gave positive assessments of the paper’s clear writing and presentation.
The clarified mathematical derivation, the additional scale-controlled experiments, and the broader empirical results substantiate the paper’s central contribution: DPO for segmentation exhibits a previously overlooked structural bias, and RN-DPO, a simple yet principled correction, yields consistent empirical improvements.
Thank you for your time and careful consideration.
Sincerely,
The Authors of Submission 27998