potentialpaper

$\texttt{NOCE-Net}$: Representation Learning for Battery Operational Context via Nested Sequence Modelling

Arnab Bhattacharjee, Wayes Tushar, Tapan Kumar Saha

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. NOCE-Net encodes actionable degradation signals from battery telemetric data, without any degradation indicating labels used for training and predicts voltage responses over very long horizons with high zero shot accuracy.

Abstract. Learning effective representations from battery operational history is essential for predictive health management and control-oriented applications. Existing approaches rely on response-dependent engineered features or short early-life windows, limiting generalisability and precluding use in prospective settings where future responses are unavailable. We propose NOCE-Net\texttt{NOCE-Net}, a deep nested sequence model that learns control-enabling representations directly from raw cyclic operational or telemetric data. Our data pipeline, re-BatteryData\texttt{re-BatteryData}, standardises heterogeneous aging datasets into semantically equivalent Full Equivalent Cycles (FECs) defined by absolute charge throughput, enabling end-to-end learning across diverse operational regimes. NOCE-Net\texttt{NOCE-Net} combines multi-patch transformer encoders for intra-cycle dynamics with a GRU backbone for inter-cycle state evolution, operating on approximately 700700 batteries across ten public datasets spanning over 300300 operational profiles. In zero-shot evaluation on unseen battery chemistries and usage patterns, NOCE-Net\texttt{NOCE-Net} achieves 13.7%13.7\% MAPE in voltage response prediction, outperforming strong long-sequence baselines by over 43%43\% while using 40×40 \times fewer parameters. Shape and component diagnostics of the learned hidden states reveal that the GRU's principal direction of evolution achieves Spearman ∣ρ∣≥0.95|\rho| \geq 0.95 with the capacity fade trajectory on average across all datasets with monotone degradation profiles, including zero-shot test batteries, providing evidence that the representations encode degradation dynamics transferable to downstream tasks beyond battery response modelling.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
4 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]—[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 2 reviews · OpenReview

Updated 25 Nov 2026, 03:44 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

This paper tackles battery-related predictions with a unified battery preprocessing framework and a carefully designed sequential model. Data processing is important but usually neglected in recent works, and it requires professional advice for scientific data. Main concerns remain in nested context and presentation.

Final justification

This paper studies representation learning from heterogeneous battery operational histories. Its main contributions are the re-BatteryData preprocessing framework, which organizes raw operational records into Full Equivalent Cycles (FECs), and NOCE-Net, which models intra-cycle dynamics and inter-cycle evolution through a nested sequence architecture. The work brings together approximately 700 batteries from ten public datasets and evaluates both voltage-response prediction and the degradation information encoded in the learned representations. The data standardization effort is substantial, the problem is practically important, and the evaluation includes challenging dataset-level zero-shot tests.

The rebuttal adequately addressed the principal clarity and experimental concerns. The authors now define nested operational context explicitly as a bilevel representation: variable-length measurements within each FEC are encoded into cycle-level features, while a recurrent backbone models evolution across FECs and a decoder reconstructs temporally resolved voltage responses. They also clarified the M1, M2, and independent evaluation modes, the meanings of the MPATCH and VARSEQ settings, the dataset-level train/test protocol, and the ablation results by adding full-model references and relative differences. These revisions should substantially improve the presentation and reproducibility of the work.

The rebuttal provides useful evidence concerning the substantive technical questions. The authors clarify that FEC is a segmentation criterion rather than an assumption that equal charge throughput implies identical degradation. Temperature, current, time, and other intra-cycle signals remain available to distinguish different operating conditions. To test whether the learned degradation representation merely tracks FEC progression, they compare against linear and nonlinear FEC-index baselines, analyze the effect of subtracting the initial hidden state, and report battery-specific fade-shape correlations. The hidden-state representation is substantially stronger than FEC-only predictors in aggregate zero-shot evaluation, although the advantage is not uniform on every dataset. These results support, but do not completely settle, the claim that the representation captures degradation dynamics beyond simple throughput progression.

The authors further explain that the M1 configurations already provide targeted hierarchical controls operating on the same nested data representation, while M2 and independent configurations respectively remove explicit nesting and inter-cycle memory. Together with the revised component ablations, these comparisons provide reasonable evidence that the reported gains cannot be attributed solely to data preprocessing. The “control-enabling” claim has also been appropriately narrowed: the model supplies a differentiable forward predictor that may support model-based optimization, rather than constituting a validated closed-loop control system.

A remaining limitation is that the architectural novelty is moderate under the General contribution criteria. NOCE-Net is primarily a domain-motivated combination of established encoders, recurrent modeling, conditioning, and decoding components, and its applicability beyond battery data is not yet demonstrated. FEC-based organization also cannot fully normalize differences in temperature, C-rate, state-of-charge range, and operational regime. Nevertheless, the unified data pipeline, physically meaningful nested formulation, broad cross-dataset evaluation, compact model, and degradation-representation analysis together constitute a valuable contribution.

Following the rebuttal, one reviewer recommends Accept, and the other raised the recommendation to Borderline Accept after finding the main concerns adequately addressed. Considering the substantial data and experimental effort, the practically relevant problem, and the strengthened evidence supplied during rebuttal, I believe the positive aspects outweigh the remaining limitations and recommend acceptance as a poster.

Area Chair QGgP · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

This paper tackles battery-related predictions with a unified battery preprocessing framework and a carefully designed sequential model. Data processing is important but usually neglected in recent works, and it requires professional advice for scientific data. Main concerns remain in nested context and presentation.

Final justification

This paper studies representation learning from heterogeneous battery operational histories. Its main contributions are the re-BatteryData preprocessing framework, which organizes raw operational records into Full Equivalent Cycles (FECs), and NOCE-Net, which models intra-cycle dynamics and inter-cycle evolution through a nested sequence architecture. The work brings together approximately 700 batteries from ten public datasets and evaluates both voltage-response prediction and the degradation information encoded in the learned representations. The data standardization effort is substantial, the problem is practically important, and the evaluation includes challenging dataset-level zero-shot tests.

The rebuttal adequately addressed the principal clarity and experimental concerns. The authors now define nested operational context explicitly as a bilevel representation: variable-length measurements within each FEC are encoded into cycle-level features, while a recurrent backbone models evolution across FECs and a decoder reconstructs temporally resolved voltage responses. They also clarified the M1, M2, and independent evaluation modes, the meanings of the MPATCH and VARSEQ settings, the dataset-level train/test protocol, and the ablation results by adding full-model references and relative differences. These revisions should substantially improve the presentation and reproducibility of the work.

The rebuttal provides useful evidence concerning the substantive technical questions. The authors clarify that FEC is a segmentation criterion rather than an assumption that equal charge throughput implies identical degradation. Temperature, current, time, and other intra-cycle signals remain available to distinguish different operating conditions. To test whether the learned degradation representation merely tracks FEC progression, they compare against linear and nonlinear FEC-index baselines, analyze the effect of subtracting the initial hidden state, and report battery-specific fade-shape correlations. The hidden-state representation is substantially stronger than FEC-only predictors in aggregate zero-shot evaluation, although the advantage is not uniform on every dataset. These results support, but do not completely settle, the claim that the representation captures degradation dynamics beyond simple throughput progression.

The authors further explain that the M1 configurations already provide targeted hierarchical controls operating on the same nested data representation, while M2 and independent configurations respectively remove explicit nesting and inter-cycle memory. Together with the revised component ablations, these comparisons provide reasonable evidence that the reported gains cannot be attributed solely to data preprocessing. The “control-enabling” claim has also been appropriately narrowed: the model supplies a differentiable forward predictor that may support model-based optimization, rather than constituting a validated closed-loop control system.

A remaining limitation is that the architectural novelty is moderate under the General contribution criteria. NOCE-Net is primarily a domain-motivated combination of established encoders, recurrent modeling, conditioning, and decoding components, and its applicability beyond battery data is not yet demonstrated. FEC-based organization also cannot fully normalize differences in temperature, C-rate, state-of-charge range, and operational regime. Nevertheless, the unified data pipeline, physically meaningful nested formulation, broad cross-dataset evaluation, compact model, and degradation-representation analysis together constitute a valuable contribution.

Following the rebuttal, one reviewer recommends Accept, and the other raised the recommendation to Borderline Accept after finding the main concerns adequately addressed. Considering the substantial data and experimental effort, the practically relevant problem, and the strengthened evidence supplied during rebuttal, I believe the positive aspects outweigh the remaining limitations and recommend acceptance as a poster.

1 comment
Authors · CommentOpenReview ↗

Response to Area Chair Metareview

We thank the Area Chair for the constructive summary. The metareview identifies two main concerns — nested context and presentation — both of which we have directly addressed in our responses to the reviewers.

On nested context. In our response to Reviewer DVGi we provide an explicit definition of the bilevel nested operational context: the outer sequence over FECs and the inner variable-length intra-cycle sequence, each processed by a distinct mechanism (Patch Encoder, GRU, Patch Decoder). We confirm that Reviewer DVGi's interpretation of the architecture was exactly correct, and we commit to adding this definition to Section 2 and the Figure 1 caption. We also clarify the three baseline evaluation modes (M1/M2/Indep.) and the MPATCH/VARSEQ flags in a dedicated table, and make the seen/unseen split protocol explicit. In our response to Reviewer Zf7D we additionally provide a detailed account of why M1 (MPATCH=True) baselines constitute targeted hierarchical comparisons — covering Transformer, LLM, MLP-mixer, and recurrent SSM inter-cycle mechanisms — without any NOCE-Net-specific conditioning.

On presentation. We have revised Table 3 (ablation study) to include the full-model reference row and percentage deltas relative to NOCE-Net's per-dataset results, directly addressing Reviewer DVGi's request.

On the substantive technical concern raised by Reviewer Zf7D (whether the PC1/capacity correlation reflects cycle-progression rather than genuine degradation encoding): we provide three independent pieces of evidence — (1) an FEC-only baseline comparison showing the frozen PID-feature head achieves 52.7% lower aggregate zero-shot MAPE than a linear FEC model and 90.5% lower than a nonlinear MLP FEC model, (2) the h0h_0 subtraction effect demonstrating the degradation signal lives in the GRU's voltage-driven dynamics rather than the FEC positional input, and (3) the shape decomposition confirming battery-specific fade structure is captured without capacity supervision.

We hope the AC and reviewers will find the responses address the core issues, and we welcome any further questions.

Reviewer Zf7DOpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
2/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper studies representation learning for battery operational history. The authors propose re-BatteryData to organize heterogeneous battery aging datasets into Full Equivalent Cycles, and propose NOCE-Net to model the nested structure of battery operation. The model uses Transformer encoders for intra-cycle dynamics and a GRU backbone for inter-cycle evolution. The learned representations are evaluated through voltage response prediction and degradation-related analysis.

I think the data organization effort is valuable. The paper collects and processes a large amount of battery data, and the nested formulation is meaningful for this domain. However, I have concerns about the method itself and the motivation behind some design choices.

Strengths and weaknesses

Strengths

1 The data effort is significant. Organizing around 700 batteries from multiple public datasets into a unified format is useful for the battery learning community.

2 The problem is practically important. Learning from long battery operational histories is relevant to battery health monitoring and future control-oriented applications.

3 The nested view is reasonable. Separating intra-cycle response dynamics and inter-cycle degradation dynamics matches the structure of battery aging data.

4The paper has a relatively broad empirical setup, including zero-shot and few-shot evaluations, rather than only testing on one small dataset.

Weaknesses

1 I think the methodological novelty is moderate. The model uses a reasonable combination of multi-patch Transformer encoders, FEC/task embeddings, a GRU backbone, and a decoder. These choices fit the battery setting, but the main contribution seems to come more from the data organization and nested formulation than from a clearly new architecture.

2 The FEC-based formulation is practical, but I think its assumptions and the degradation-representation claim need a bit more care. Organizing histories by charge throughput is useful for aligning heterogeneous datasets, but the same throughput can still correspond to different aging conditions due to temperature, C-rate, SOC range, and usage pattern. Also, since the model uses FEC-related inputs, the correlation between hidden states and capacity fade may partly reflect cycle progression or throughput. A simple control without FEC conditioning, or an analysis controlling for FEC index, would make this part more convincing.

3 The empirical comparison could be more targeted. The paper compares with general long-sequence models, which is helpful, but it is still hard to tell how much gain comes from the proposed nested modeling design itself. Simpler hierarchical baselines using the same re-BatteryData format, such as a basic patch encoder plus GRU, and variants without task/FEC conditioning, would make the conclusions clearer.

Questions
  1. Please clarify the role of the FEC formulation. I understand that charge-throughput-based segmentation is practical, but the same FEC can still correspond to different aging conditions under different temperature, C-rate, or SOC range. It would help to discuss this assumption more clearly, and explain why FEC is preferable to simpler cycle-based or time-based organization.

  2. Can the authors better support the degradation-representation claim? Since FEC-related inputs are used by the model, the hidden state may partly track cycle progression or throughput. A control without FEC conditioning, or a comparison with FEC index alone, would make this claim more convincing.

  3. A more targeted baseline would be useful. The current baselines are mostly general long-sequence models. A simple hierarchical baseline using the same re-BatteryData format, such as patch encoder + GRU, would better show what NOCE-Net adds.

  4. Please clarify the “control-enabling” claim. The model predicts voltage under given future operational inputs, but it is not clear how it would be used in a real control loop, especially when future temperature may not be known or controllable.

Limitations

Yes. The authors mention some limitations and future directions. The discussion could be slightly improved by noting that FEC-based segmentation may not fully capture differences in temperature, C-rate, SOC range, or usage pattern. It would also help to briefly mention that real deployment or control use would need stronger validation.

Final justification

The additional experiments and clarifications adequately addressed my concerns. Therefore, I have increased my score by one point to 4.

Formatting concerns

I did not notice any major formatting or anonymity issues in the visible manuscript.

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Rebuttal to Reviewer Zf7D

We thank the reviewer for the thorough reading and for recognising the value of the data effort, the practical importance of the problem, and the broad empirical setup.


W1 — "Methodological novelty is moderate"

We agree and do not claim architectural novelty as a primary contribution. The contributions are: (1) a unified data pipeline for nested operational context, (2) a large-scale dataset of 700 batteries across 300+ profiles, (3) task-conditioned nested modelling for zero-shot voltage prediction, and (4) the empirical finding that voltage-forecasting supervision yields degradation-encoding representations transferable to zero-shot batteries. The architecture is a domain-motivated composition of known components. We will strengthen this framing in the revision.


W2/Q1 — "Same throughput ≠ same aging under different temperature, C-rate, SOC"

The reviewer is correct. The FEC boundary is a segmentation criterion, not a claim of identical degradation conditions. Within each FEC, the full intra-cycle record — current (capturing C-rate), temperature, and time — is available as Uc∈RLc×du\mathbf{U}_c \in \mathbb{R}^{L_c \times d_u}. Two FECs with identical throughput but different profiles produce different intra-cycle encodings and different GRU transitions. FEC-based segmentation solves a different problem: it creates a semantically comparable operational unit across heterogeneous datasets where charge-discharge counts are incomparable (Appendix B.1.3). We will add to Section 2.1: "FEC-based segmentation does not fully account for degradation pathway differences arising from temperature, C-rate, or SOC variations; the model mitigates this through full intra-cycle current and temperature signals."


W2/Q2 — "Correlation between hidden states and capacity may partly reflect cycle progression"

We provide three arguments that PC1(H)/Q correlation is not a FEC-tracking artefact.

Argument 1 — FEC-only baseline. We train a Linear and MLP model mapping only normalised FEC index cnorm∈[0,1]c_\text{norm} \in [0,1] (no hidden state) to SOH and compare against the PID feature extracted from frozen hidden states + SOH head model (Table 11 in the paper). Δ = (FEC MAPE − PID MAPE)/PID MAPE.

In-Sample

Dataset PID MAPE Lin MAPE Δ Lin MLP MAPE Δ MLP
MATR 39.06% 93.18% +138.6% 108.69% +178.3%
XJTU-Partial 28.59% 98.90% +245.9% 117.11% +309.6%
TJU 102.07% 124.89% +22.4% 158.87% +55.6%
ISU-ILCC 143.73% 73.69% −48.7% 88.43% −38.5%
NASA Rand 208.97% 106.79% −48.9% 119.00% −43.1%
Total 98.90% 86.01% −13.0% 103.16% +4.3%

Zero-Shot

Dataset PID MAPE Lin MAPE Δ Lin MLP MAPE Δ MLP
NASA-PCoE 16.59% 73.45% +342.7% 74.31% +347.9%
HUST 72.75% 118.04% +62.3% 147.92% +103.3%
XJTU-Full 75.78% 110.32% +45.6% 135.01% +78.2%
Stanford-EV 106.11% 68.90% −35.1% 67.52% −36.4%
Total 76.30% 116.51% +52.7% 145.38% +90.5%

On zero-shot batteries the PID head achieves 52.7% lower aggregate MAPE than FEC-Linear and 90.5% lower than FEC-MLP. Even a nonlinear MLP with direct FEC access cannot match the frozen hidden-state representations, confirming the hidden states encode battery-specific degradation structures like rate, shape, and knee beyond throughput tracking. The FEC-only advantage on Stanford-EV and the in-sample ISU-ILCC/NASA-Rand reflects known affine miscalibration of the PID head on slow-fade and OOD batteries (Table 12, Section 4.3).

Argument 2 — h0h_0 subtraction. Table 10 shows that raw ∥hc∥2\|h_c\|_2 achieves ∣ρ∣=0.750|\rho|=0.750 on zero-shot batteries despite receiving the same FEC positional input γc=[c,Δc]\gamma_c=[c,\Delta c] as the relativised representation, recovering to ∣ρ∣=0.997|\rho|=0.997 after subtracting h0h_0. If the hidden state trivially forwarded the FEC scalar, the raw norm would already be near-perfect. The recovery proves the degradation signal lives in the GRU's voltage-driven temporal dynamics, not the FEC input.

Argument 3 — Shape decomposition. Fig. 10 and Tab. 12 provide evidence that PC1 captures battery-specific fade shape (mean Pearson r=0.856r=0.856), including curvature and knee regions that a scalar FEC index cannot encode. A throughput-tracking representation would likely produce lower shape correlation for nonlinearly-fading batteries.


W3/Q3 — "A targeted hierarchical baseline (patch encoder + GRU) would better isolate what NOCE-Net adds"

The M1 evaluation mode already constitutes this comparison. When MPATCH=True, every M1 baseline uses a multi-patch convolutional embedding (same design as NOCE-Net's Patch Encoder) for intra-cycle sequences, feeding its own inter-cycle mechanism — with no task conditioning, FEC conditioning, or learnable aggregator tokens:

Mode Nested Patch embedding Inter-cycle memory Conditioning
M1 (T,T) ✓ Multi-patch conv. ✓ baseline's own ✗
M1 (F,T) ✓ MLP ✓ baseline's own ✗
M2 ✗ Flat Implicit ✗
Indep. ✗ Flat None ✗
NOCE-Net ✓ Multi-patch conv. ✓ GRU (explicit) ✓

M1 (MPATCH=T) baselines are the requested targeted hierarchical comparison. When MPATCH=True, each M1 baseline uses a multi-patch convolutional embedding for intra-cycle sequences — the same design as NOCE-Net's Patch Encoder. The cycle-level aggregates are then passed to the baseline's own inter-cycle mechanism. None of these baselines have task conditioning, FEC conditioning, or learnable aggregator tokens. The four M1 architectures therefore span the design space of "patch encoder + X inter-cycle mechanism" across all major architectural families, all operating on the same re-BatteryData nested format:

  • TimerXL M1 (T,T) — multi-patch intra-cycle encoder + Transformer inter-cycle attention (long-context attention across FEC-level features). Best M1 Total-Unseen: MAE = 0.273 / MAPE = 63.4%.
  • AutoTimes M1 (T,T) — multi-patch intra-cycle encoder + LLM-adapted (GPT-2) inter-cycle mechanism (autoregressive prediction over FEC-level tokens). Best M1 Total-Unseen: MAE = 0.129 / MAPE = 32.7%.
  • TTM M1 (F,T) — MLP-embedded intra-cycle + MLP-mixer inter-cycle temporal mixing (lightweight patch-mixing without attention). Best M1 Total-Unseen: MAE = 0.117 / MAPE = 25.4%.
  • MAMBA M1 — multi-patch intra-cycle encoder + selective state-space (recurrent) inter-cycle mechanism. MAMBA is a recurrent model with selective state updates, making M1 MAMBA the closest available analogue to the "patch encoder + GRU" the reviewer describes.

The best M1 baseline (TTM, F,T) achieves Total-Unseen MAE = 0.117 / MAPE = 25.4%, versus NOCE-Net's 0.0656 / 13.7% — a 44% MAE / 46% MAPE gap on an identical nested data format, without NOCE-Net's task or FEC conditioning.

M2 baselines test what happens when nested structure is discarded. Each baseline in M2 mode receives a flattened sequence of length L1+L2+⋯+LNL_1 + L_2 + \cdots + L_N, collapsing the bilevel structure into a single level. Comparing M1 vs. M2 for the same architecture directly tests the value of preserving the nested structure. MAMBA M2 achieves Total-Unseen MAE = 0.100 / MAPE = 43.4% — worse than several M1 configurations, confirming that flattening degrades performance even for a strong recurrent architecture.

Independent baselines test the extreme case: no inter-cycle memory. In Indep. mode each FEC is treated as an independent sample with no shared state between cycles. This isolates the contribution of inter-cycle memory entirely. MAMBA Indep. achieves Total-Unseen MAE = 0.109 / MAPE = 28.6%. The progression Indep. MAMBA (0.109) → MAMBA M2 (0.100) → best M1 TTM (0.117) → NOCE-Net (0.0656) shows that inter-cycle memory helps, nested structure matters, and NOCE-Net's task-conditioned GRU with FEC embeddings provides substantial additional gains beyond what any unconditioned hierarchical baseline achieves.

Ablations decompose the remaining gap. The revised Table 3 (with deltas, shared in response to Reviewer DVGi) then shows what each NOCE-Net-specific addition contributes beyond the bare hierarchical structure: task conditioning (+112% Total MAE when removed), FEC conditioning (+113%), learnable aggregator (+118%), and recurrent backbone (+144%). Taken together, M1 (hierarchical + patch encoder, no conditioning), M2 (flat, no hierarchy), Indep. (no inter-cycle state), and the ablations constitute a full decomposition of NOCE-Net's contribution over a simple hierarchical baseline.

Revision. Specify the M1 mode description in Section 3.2 to explicitly state that M1 (MPATCH=T) baselines serve as targeted hierarchical comparisons on the re-BatteryData format without NOCE-Net-specific conditioning.


Q4 — "Clarify the 'control-enabling' claim"

We use "control-enabling" to mean: a differentiable forward model of voltage response to planned operational inputs — a prerequisite for model-based battery optimisation, not a claim of closed-loop deployment readiness. Temperature enters the model as an input feature (T∈duT \in d_u), so NOCE-Net can be used in two practically relevant settings: (a) when temperature is actively controlled or regulated (as in many BMS designs), or (b) in predictive planning scenarios where temperature is forecasted or treated as a scenario variable. We do not claim the model is immediately deployable in uncontrolled real-world settings without further validation. We will redefine "control-enabling" in Section 1 as a prerequisite for model-based control rather than a claim of deployment readiness, and add to limitations: "Closed-loop deployment requires controllable or reliably forecasted temperature; stronger real-world validation is an open challenge."

Reviewer Zf7D · CommentOpenReview ↗

Thank you for the detailed rebuttal and the substantial data curation and experimental effort; the clarifications largely address my concerns regarding the nested context, FEC formulation, evaluation protocol, and control-enabling claim, so I will raise my score to 4.

Authors · CommentOpenReview ↗

Dear Reviewer Zf7D,

We sincerely thank you for reading our response and for considering to raise the score. We noticed that the official score in the system hasn't been updated yet. We humbly request you to update the official rating on the platform when you have a moment so it reflects your assessment. Thank you for the review, your time and your help.

Reviewer DVGiOpenReview ↗
Rating
5/6
Confidence
3/5
Quality
3/4
Clarity
2/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper proposes 1) a unified battery preprocessing framework that standardizes heterogenous battery aging datasets into a nested structure, 2) a hybrid architecture based on 1d-convolutions, transformer blocks as encoders, a GRU in the middle, followed by another transformer and a temporal reconstruction. This combines transformer encodings and GRUs. They evaluate their learned representation on voltage forecasting and a downstream task (SOH estimation). They have a notable sequence-defining preprocessing by using the FEC definition.

Strengths and weaknesses

strengths: The FEC-based segmentation is interesting.

The architecture is a bit different from the many others in that it seems that the transformer encoder encodes one FEC cycle into one feature per cycle, this feature is then aggregated between cycles by the GRU network, then the patch decoder produces from it a sequence of temporally resolved voltage predictions

The proposed model is small in size which is an appealing property. The hierarchical decomposition of data and architecture is nicely motivated.

on the weakness side: It is unclear what nested context is . It could mean a computation of a FEC-cycle-specific aggregated feature as hidden state by the GRU, and a time-based prediction of voltage states within one FEC using the temporal heads on top of it. This is a mere guess. It is not clearly defined in the paper.

What does this mean: "(dis)enabling multi-patch embedding (MPATCH) and variable-length sequence (VARSEQ) features; " ?

It is not really clear how unseen tests were defined (batteries from the test set not used in training and validation?).

It would be a good standard to train on N-k (k=1 is ok) battery datasets, test on 1, for-loop over the withheld test set, and then report the cross-dataset generalization performance, similar to cross-site studies in medicine.

The authors have not shown deltas or differences for Table 3. making it inconvenient for comparing with original results. This could have been presented much better.

Weak accept primarily due to the unclarities. The reviewer thinks that the paper has potential.

Questions

The reviewer understands the definition of a sequence boundary via FEC and its physical motivation. The reviewer understands that there is a temporally resolved prediction of voltage within one FEC-defined sub-sequence.

It is not clear what nested context is ? What is the difference between M1 and M2 . What is flattened in M2 ? What does this mean: "(dis)enabling multi-patch embedding (MPATCH) and variable-length sequence (VARSEQ) features; " ? What is then (Indep.) independent per-cycle modelling ?

Limitations

Seems well done/

Final justification

For a "general" category the submission has limited methodical novelty, as noted by the other reviewer. With the suggested clarifications the readability of this paper improves substantially. With a narrow reading one could argue that the score remains the same due to the category change - then this paper would remain at a tie. This reviewer is agreeable to disagree with the program chairs ;) .

The reviewer is not knowledgeable about battery prediction networks, thus the low certainty ("that you are unfamiliar with some pieces of related work"), however the reviewer finds the paper with the proposed revisions okay to be accepted ("with high potential value on at least one sub-area of AI " - yes, for batteries), and thus increases the score as if this would be a use-inspired paper (seriously, it is not ?).

Formatting concerns

NA

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

Rebuttal to Reviewer DVGi

We thank the reviewer for the constructive assessment, for recognising the potential of the FEC-based segmentation and hierarchical design, and for the borderline-accept rating. We note that all raised concerns relate to clarity of exposition rather than technical validity, and we address each below with concrete revisions to the paper.


W1 / Q1 — "It is unclear what nested context is"

Response. By nested operational context we mean a two-level (bilevel) sequence representation:

  • Outer sequence: over full equivalent cycles (FECs), c∈[1,…,N]c \in [1, \ldots, N].
  • Inner sequence: nested within each FEC, the variable-length intra-cycle time series of operational inputs Uc∈RLc×du\mathbf{U}_c \in \mathbb{R}^{L_c \times d_u}.

NOCE-Net processes these two levels with different mechanisms: the Patch Encoder compresses each inner (intra-cycle) sequence into a single fixed-dimensional feature vector; the GRU backbone propagates information across the outer (inter-cycle) sequence; and the Patch Decoder expands the GRU state back into a temporally-resolved intra-cycle voltage response.

The reviewer's interpretation — "a computation of a FEC-cycle-specific aggregated feature as hidden state by the GRU, and a time-based prediction of voltage states within one FEC using the temporal heads on top of it" — is exactly correct.

Revision: We will add this explicit bilevel definition to Section 2 (immediately before Section 2.1) and to the Figure 1 caption.


Q2 — "What is the difference between M1 and M2? What is flattened in M2? What do MPATCH and VARSEQ mean? What is Indep.?"

Response. We evaluated three modes of applying off-the-shelf long-sequence models to battery data, designed to isolate the contribution of the nested structure itself:

Mode Nested structure Intra-cycle embedding Variable length Inter-cycle memory
M1 (F, F) ✓ MLP Pooled to fixed length ✓ (baseline's own)
M1 (F, T) ✓ MLP Preserved (padded) ✓
M1 (T, F) ✓ Multi-patch conv. Pooled to fixed length ✓
M1 (T, T) ✓ Multi-patch conv. Preserved (padded) ✓
M2 ✗ Flat single-level N/A Implicit only
Indep. ✗ Flat single-level N/A None
NOCE-Net ✓ Multi-patch conv. Preserved natively ✓ GRU + task/FEC conditioning

Concretely, for a battery with 3 FECs of intra-cycle lengths L1,L2,L3L_1, L_2, L_3:

  • M1 treats the data bilevelly, exactly as NOCE-Net does: each cycle is encoded separately and passed through the baseline's inter-cycle mechanism.
  • M2 sees a single unbroken flattened sequence of length L1+L2+L3L_1 + L_2 + L_3 — the nested boundary information is discarded entirely.
  • Indep. sees C1C_1, C2C_2, C3C_3 as three completely independent sequence samples with no shared state between them.

The two binary flags in M1 control exactly how the baseline handles the inner sequence:

  • MPATCH: whether intra-cycle inputs are embedded with a multi-patch convolutional layer (True) or a plain MLP (False). When (True), the output reconstruction layer from NOCE-Net is applied to generate the voltage response, which in the (False) case is created using an MLP head in the time dimension.
  • VARSEQ: whether variable intra-cycle lengths are preserved via max-length batch padding (True) or attention-pooled to a fixed length (False).

M1 (MPATCH=T, VARSEQ=T) is therefore the closest structural analogue to NOCE-Net among all baselines — the only differences are the baseline's own inter-cycle mechanism and the absence of task/FEC conditioning.

Revision: We will add this table and the concrete three-cycle example to Section 3.2 with explicit definitions of MPATCH and VARSEQ.


W3 — "It is not really clear how unseen tests were defined"

Response. Test batteries are held out at the dataset level, not the battery level. Datasets marked "Train" in Table 1 contribute batteries to training, validation, and in-sample test splits (6:2:2). The held-out in-sample test batteries form Total-Seen — unseen batteries from seen chemistries. The five datasets marked "Test" (NASA-PCoE, Stanford-EV, HUST, XJTU-Full, evTOL) are excluded from training entirely — no battery from them is ever seen at any stage — and constitute Total-Unseen, our zero-shot cross-chemistry and cross-operational-regime evaluation.

Revision: We will add this explicit description of the split protocol to Section 3.1 and to the caption of Table 2.


W4 — "It would be a good standard to train on N−k datasets, test on 1 (leave-one-out)"

Response. We agree that cross-dataset generalisation is the right thing to measure. Our evaluation was specifically designed with this in mind. Total-Unseen already constitutes a strict cross-dataset test: five entire datasets are held out simultaneously, spanning chemistries (LFP, NMC, NCA, Graphite/Silicon), form factors, and operational regimes entirely absent from training. We further deliberately included Stanford-EV (EV drive-cycle profiles, silicon-graphite anodes) and evTOL (aircraft discharge profiles) as the most out-of-distribution datasets, making the test more demanding than a standard LOO sweep over similar lab-cycling datasets.

Holding out five diverse datasets simultaneously is arguably more demanding than leave-one-out: the model must generalise to multiple unseen distributions at once rather than a single one, without any opportunity to implicitly leverage the held-out dataset's profile through the remaining training data. A full LOO sweep would multiply training cost by the number of datasets (×10); we agree it is a valuable robustness study and will note it as future work.


W5 — "The authors have not shown deltas or differences for Table 3"

Response. We have revised Table 3 to include the full-model reference row and percentage deltas. The revised table is shown below.


Table 3 (Revised): Ablation Study with Deltas vs. Full NOCE-Net

Percentage change relative to full model shown in parentheses. ↑ = degradation (higher error), ↓ = improvement vs. full model.

MAE (lower is better)

Model NASA-PCoE Stanford-EV HUST XJTU-Full evTOL Total
NOCE-Net (full) 0.0897 0.1422 0.0574 0.0415 0.0778 0.0656
wo Task Emb. 0.178 (↑+98%) 0.120 (↓−16%) 0.130 (↑+127%) 0.180 (↑+334%) 0.141 (↑+81%) 0.139 (↑+112%)
wo FEC Emb. 0.179 (↑+100%) 0.120 (↓−16%) 0.130 (↑+127%) 0.185 (↑+346%) 0.142 (↑+83%) 0.140 (↑+113%)
wo Learn Emb. 0.180 (↑+101%) 0.164 (↑+15%) 0.130 (↑+127%) 0.185 (↑+346%) 0.142 (↑+83%) 0.143 (↑+118%)
wo Rec. Backbone 0.167 (↑+86%) 0.140 (↓−2%) 0.154 (↑+168%) 0.175 (↑+322%) 0.134 (↑+72%) 0.160 (↑+144%)

MAPE (%) (lower is better)

Model NASA-PCoE Stanford-EV HUST XJTU-Full evTOL Total
NOCE-Net (full) 15.16 17.99 14.61 7.77 13.31 13.71
wo Task Emb. 33.68 (↑+122%) 16.97 (↓−6%) 43.99 (↑+201%) 34.92 (↑+349%) 23.61 (↑+77%) 26.85 (↑+96%)
wo FEC Emb. 33.60 (↑+122%) 16.82 (↓−7%) 43.84 (↑+200%) 34.57 (↑+345%) 23.58 (↑+77%) 26.72 (↑+95%)
wo Learn Emb. 33.56 (↑+121%) 21.82 (↑+21%) 43.80 (↑+200%) 34.42 (↑+343%) 23.57 (↑+77%) 27.13 (↑+98%)
wo Rec. Backbone 30.64 (↑+102%) 18.19 (↑+1%) 44.30 (↑+203%) 31.65 (↑+307%) 22.32 (↑+68%) 36.84 (↑+169%)

Note on Stanford-EV (↓ entries): Removing task/FEC embeddings reduces error on Stanford-EV (silicon-graphite anodes, EV profiles — the most chemically distinct dataset from the training distribution). This is interpretable: the embeddings encode training-distribution chemistry priors that provide an inductive bias helpful for seen chemistries but slightly counterproductive for the most novel chemistry. The recurrent backbone has near-zero effect on Stanford-EV (only 6 homogeneous batteries with short, consistent cycles), consistent with inter-cycle memory mattering primarily for batteries with long, variable operational histories.


Summary of Revisions

Point Revision
W1/Q1 Add bilevel definition of nested context to Section 2 and Figure 1 caption
Q2 Add M1/M2/Indep. clarification table + three-cycle example to Section 3.2
W3 Add explicit dataset-level split protocol description to Section 3.1 and Table 2 caption
W4 Add sentence clarifying zero-shot protocol and note LOO as future work
W5 Add NOCE-Net reference row and percentage deltas to Table 3

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…