potentialpaper

STRAND: Sequence-Conditioned Transport for Single-Cell Perturbations

Boyang Fu, Sameer Gabbita, George Dasoulas, xiang lin, Shanghua Gao, Xiaorui Su, Soumya Ghosh, Marinka Zitnik

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. STRAND is a generative model that predicts how cells respond to genetic perturbations by conditioning on the DNA sequence at the sequence resolution perturbation site

Abstract. Predicting how genetic perturbations change cellular state is a core problem for building controllable models of gene regulation. Perturbations at the same gene can produce different transcriptional responses depending on their genomic locus, including different transcription start sites and regulatory elements; gene-level perturbation models collapse these distinct interventions into a single representation. We introduce STRAND, a generative model that predicts single-cell transcriptional responses by encoding regulatory DNA sequence at the perturbation locus and using it to parameterize a conditional transport process from control to perturbed cell states. Sequence conditioning supports zero-shot inference at perturbation targets unseen during training and locus-resolved inputs across a 524,kb window at 128,bp model resolution. On CRISPRi datasets in K562, Jurkat, and RPE1 cells, STRAND improves few-shot perturbation discrimination by up to 33%, achieves the best average rank on unseen-gene benchmarks, and improves held-out-cell-line transfer by up to 0.12 in Δ\DeltaPearson; ablations attribute these gains to both sequence conditioning and conditional transport. At the locus level, STRAND distinguishes alternative transcription start sites and validated regulatory elements that gene-identifier models treat as identical perturbations

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
4 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]—[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 2 reviews · OpenReview

Updated 25 Nov 2026, 03:45 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

This paper proposes a sequence-conditioned transport model for single-cell perturbation prediction. It is a meaningful step for virtual-cell and regulatory-genomics models by moving from gene-level perturbation labels to sequence-defined loci. Nevertheless, experiments are not sufficient. Thus far, the proposed method is demonstrated only on one dataset. Besides that, this work lacks computational efficiency comparisons with the existing counterparts. Also, baseline fairness and ablation control should be stricter.

Final justification

After reading the authors' rebuttal and the reviewers' feedback, my previous recommendation remains unchanged.

Area Chair aSwf · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

This paper proposes a sequence-conditioned transport model for single-cell perturbation prediction. It is a meaningful step for virtual-cell and regulatory-genomics models by moving from gene-level perturbation labels to sequence-defined loci. Nevertheless, experiments are not sufficient. Thus far, the proposed method is demonstrated only on one dataset. Besides that, this work lacks computational efficiency comparisons with the existing counterparts. Also, baseline fairness and ablation control should be stricter.

Final justification

After reading the authors' rebuttal and the reviewers' feedback, my previous recommendation remains unchanged.

1 comment
Authors · CommentOpenReview ↗

We thank the AC for recognizing that moving from gene-level perturbation labels to sequence-defined loci is a meaningful step for virtual-cell and regulatory-genomics models. Our reviewer responses now provide additional experiments addressing each concern in the meta-review.

Generalization. We clarify that the submitted evaluation already contained three leave-one-cell-line-out experiments spanning three screens from two studies (App. K.1, Fig. S2). In the Jurkat fold, the entire source study (Nadig et al., 2025) was excluded from training. We further added HCT116 from a third study using a distinct FiCS protocol, evaluated with a frozen checkpoint and no HCT116 perturbation profiles, labels, retraining, or adaptation. On HCT116, STRAND reaches 0.578 direction match, compared with 0.534 for STATE and 0.499 for STACK and the no-change control. Its paired gain over the stronger learned baseline is +0.045 [95% CI: +0.029, +0.059]. Across all four held-out cell lines, STRAND is the only method that exceeds the no-change control in every fold.

Computational efficiency. We now report matched end-to-end, ablation, diffusion-step, locus-scan, inference, and dataset-scaling costs on one H100. Across the five configurations completed by all methods, total costs are 24.7 GPU-h for STRAND, 22.2 for STATE, and 28.5 for GEARS. Over an approximately tenfold increase in dataset size, cost increases 1.7× for STRAND, 2.1× for STATE, and 9.4× for GEARS. Locus scans covering 81–118 coordinates complete in 3.5–7.6 minutes; gene-conditioned methods do not define an equivalent noncoding-coordinate scan to compare with.

Baseline fairness and ablations. We reran Linear using STRAND’s full 524-kb context while holding the frozen encoder, splits, training, and evaluation fixed. Expanding its context changed no few-shot metric by more than 0.026: Linear remains near chance on Discrimination Cosine at both widths (5.02–5.09; chance = 5.0), whereas STRAND reaches 7.11–7.23. We also tested each component separately, changing only one at a time. These experiments complement the submitted controls for the alignment objective, transport model, and how the perturbation coordinate is defined.

We hope the AC will consider this additional evidence when finalizing the recommendation.

Reviewer FyWyOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
4/4
Significance
3/4
Originality
3/4
Contribution type
use_inspired
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

Authors propose a generative model for perturbation of single-cell transcriptomics data by interfering the regulatory DNA segments rather than interfering the genes.

Strengths and weaknesses

Strengths

  1. Proposes a novel method by interfering DNA and by using an Optimal Transport mechanism
  2. Experiments show that method outperforms existing methods
  3. Ablation studies
  4. The manuscript is easy to follow

Weakness

  1. The method is demonstrated only on one dataset
  2. To demonstrate generalizability, you may want to train one dataset and test on another data set.
Questions

The method is demonstrated only on one dataset. Maybe to demonstrate generalizability, you may want to train one dataset and test on another data set.

Limitations

Yes

Final justification

Considering the novelty and the weaknesses highlighted above

Formatting concerns

Nil

3 comments
Authors · CommentOpenReview ↗

Thank you for recognizing STRAND’s novelty, empirical results, and clarity.

“Train on one dataset and test on another.”

This is already the design, and we have now extended it. The submitted evaluation contains three leave-one-cell-line-out experiments spanning three screens from two source studies. In the submitted cross-study Jurkat fold (App. K.1, Fig. S2), STRAND was trained only on the Replogle et al. (2022) K562 and RPE1 screens and evaluated on the independently generated Nadig et al. (2025) Jurkat screen. It used no Jurkat perturbation profiles, labels, or target-context fine-tuning.

To go further, we added a zero-shot evaluation on HCT116 from X-Atlas/Orion (Huang et al., 2025), an independent study on the FiCS fix–cryopreserve platform. We use a frozen checkpoint trained on K562, RPE1, and Jurkat, with no HCT116 retraining or adaptation. All methods received the same HCT116 controls and were evaluated on the same 300 perturbations.

Table R1. Held-out contexts and transfer design.

Held-out context Source; assay/platform Training screens
K562 Replogle et al. (2022); single-sgRNA CRISPRi, 10x Genomics RPE1 + Jurkat
RPE1 Replogle et al. (2022); single-sgRNA CRISPRi, 10x Genomics K562 + Jurkat
Jurkat Nadig et al. (2025); dual-sgRNA CRISPRi, 10x Genomics K562 + RPE1; source study fully held out
HCT116 (new) Huang et al. (2025), X-Atlas/Orion; dual-sgRNA CRISPRi, FiCS Perturb-seq K562 + RPE1 + Jurkat; source study and protocol fully held out

Thus, the evaluation now covers four held-out cell lines from three studies; two folds exclude the entire source study from training.

Table R2. Direction match in zero-shot transfer. Means [95% bootstrap CI] over 300 perturbations/fold, averaged across top-K=5–100 gene cutoffs. Δ values are paired per-perturbation differences; parentheses give the percentage of perturbations on which STRAND wins. Chance=0.50. K562, RPE1, and Jurkat are submitted; HCT116 is new.

Held-out line No-change STATE STACK STRAND Δ vs stronger baseline (% win) Δ vs no-change (% win)
K562 0.492 0.492 0.524 0.554 [0.534, 0.571] +0.029 [+0.015, +0.044] (55%) +0.062 [+0.040, +0.081] (62%)
RPE1 0.503 0.430 0.482 0.631 [0.615, 0.648] +0.150 [+0.122, +0.179] (72%) +0.129 [+0.107, +0.152] (76%)
Jurkat (study held out) 0.497 0.542 0.518 0.591 [0.573, 0.607] +0.049 [+0.038, +0.059] (73%) +0.093 [+0.073, +0.112] (73%)
HCT116 (new study/protocol) 0.499 0.534 0.499 0.578 [0.564, 0.593] +0.045 [+0.029, +0.059] (65%) +0.080 [+0.063, +0.096] (72%)

For HCT116, no perturbed expression profiles or labels were used for training or adaptation: only unperturbed controls were available at inference. STRAND is the only method that beats the no-change control in every fold; STATE and STACK each fall at or below it in two of the four.

Table R3. Paired improvement in effect correlation (ΔPearson). STRAND minus baseline per perturbation [95% bootstrap CI], followed by win percentage; 300 perturbations/fold, averaged across top-K=5–100. STRAND exceeds both baselines in all four folds; seven of eight CIs exclude zero.

Held-out line Δ vs STATE (% win) Δ vs STACK (% win)
K562 +0.078 [+0.059, +0.094] (70%) +0.070 [+0.051, +0.089] (67%)
RPE1 +0.176 [+0.153, +0.201] (81%) +0.083 [+0.047, +0.118] (59%)
Jurkat (study held out) +0.029 [+0.016, +0.041] (69%) +0.038 [+0.018, +0.058] (65%)
HCT116 (new study/protocol) +0.015 [−0.004, +0.033] (54%) +0.074 [+0.050, +0.099] (61%)

In the revision, Sec. 4 will identify each screen’s source study and describe the design as cross-study, leave-one-context-out transfer. The appendix will report complete HCT116 results for every method and metric. The submitted Jurkat fold establishes transfer across studies, while HCT116 extends this to a new study and protocol (Tables R1–R3); the evaluation is therefore not confined to one dataset.

We would be grateful if the reviewer would weigh this evidence in the final assessment.

Reviewer FyWy · CommentOpenReview ↗

Noted on the addition experiments done.

Authors · CommentOpenReview ↗

We thank the reviewer for noting the additional experiments done.

The updated evaluation now covers four held-out cell lines from three independent studies. The Jurkat and HCT116 folds each hold out the entire source study; HCT116 additionally uses a different platform and protocol. In every fold, no perturbation profiles from the held-out cell line were used for training, and no retraining or adaptation to that cell line was performed.

Across the four folds, STRAND is the only method that remains above the no-change control on Direction Match. The HCT116 experiment directly implements the cross-dataset evaluation suggested in the review.

We hope this resolves the generalization concern. If so, we would be grateful if the reviewer could update their assessment accordingly.

Reviewer 8EGqOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
4/4
Clarity
3/4
Significance
3/4
Originality
4/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes STRAND, a sequence-conditioned transport model for single-cell perturbation prediction. Instead of conditioning on gene identifiers, STRAND uses regulatory DNA sequence around a specified perturbation locus, a perturbation mask, a frozen DNA encoder, a frozen RNA cell-state encoder, OT-based endpoint pairing, an I2SB-style latent bridge, and a residual hurdle decoder.

Strengths and weaknesses

Strengths: Moving from gene-level perturbation labels to sequence-defined loci is a meaningful step for virtual-cell and regulatory-genomics models.

Weakness:

  1. Lacks computational efficiency comparisons with other methods. Although the paper reports per-cell-line training time, it does not quantify benchmark, ablation, diffusion-step tuning, or locus-resolved inference costs; such scans may be substantially slower than gene-level baselines.
  2. Appendix G.2 also describes Delta Pearson using an "absolute difference" while the formula uses the signed difference pbar_t - cbar_t; this changes the interpretation of directionality.
  3. Baseline fairness and ablation control should be stricter. The Linear baseline uses a much smaller 7 kb TSS-centered mean-pooled Borzoi context, while STRAND uses a 524 kb context.
Questions

NA

Limitations

Yes

Formatting concerns

NA

1 comment
Authors · CommentOpenReview ↗

We thank the reviewer for recognizing that moving from gene-level labels to sequence-defined loci is a meaningful step for virtual-cell models.

1. Computational efficiency

Single-GPU wall-clock, one H100 80GB, submitted config (GEARS/STRAND 20 epochs; STATE 40k steps).

Cost GPU-h
Benchmark: 5 configs all methods finished (Jurkat/RPE1 both panels, K562 2k-HVG) STRAND 24.7 (9.4 prep+15.3 train); GEARS 28.5 (22.3+6.2); STATE 22.2 (2.8+19.4)
Full 6-config grid STRAND ~29.5; STATE ~29.1; GEARS time out after 40 hours
Ablations: 3 variants x 3 cell lines <=29.4 for all 9 runs
Diffusion sweep, T in {2,6,10,20,50,100} 3.6, no retraining
Locus scan, 81-118 coordinates 3.5-7.6 min per scan

On the five shared configurations, STRAND falls between STATE and GEARS. Across all six, STRAND and STATE are nearly identical; STRAND uses ~20% less training time. Ablations reuse SCimilarity embeddings and OT coupling; rerunning preprocessing per arm would add 18.8 GPU-h.

T (sampling step) is used at inference. Each step adds ~1.52 ms for 256 cells, so the default T=10 is 15 ms of a 2.96 s prediction yet already reaches 97.2% of the T=100 discrimination score and 97.9% of its ΔPearson. T is never tuned per locus, so step selection adds no cost to any reported result.

STRAND can query any coordinate, including noncoding sites. A scan advances by 100 bp; each query reads 524 kb and predicts 256 cells. Sequence encoding takes 0.180±0.009 s of the 2.96-s total; transport/decoding takes 2.785±0.020 s. Sequence conditioning, which enables coordinate-level prediction, is 6.1% of runtime and runs once per coordinate, not per cell. Gene-conditioned GEARS, STATE, and STACK have no equivalent noncoding scan. On matched Jurkat output (48 cells/perturbation; startup excluded), STACK took 5.5 s versus 0.28 s for STRAND (20×).

Across 19,183→191,466 Jurkat cells (~10×), with perturbations, task, and budgets fixed, cost grew 9.4× for GEARS, 2.1× for STATE, and 1.7× for STRAND. Details will be added to Appendix L.

2. ΔPearson definition

The reviewer is correct: the prose conflicts with Eq. S36. The equation and implementation use signed changes. For each perturbation, we subtract the mean control from the mean perturbed profile in both observed and predicted data, correlate these changes across genes, and average across perturbations. Sign is retained, so reversing up- and down-regulation is penalized. We will replace “absolute” with “signed difference” in Appendix G.2. No reported value or conclusion changes.

3. Baseline fairness and ablation controls

We reran Linear with STRAND's full 524-kb Borzoi context, changing only the pooling window (identical frozen encoder, splits, training, evaluation). It uses 2,000 HVGs, so values are not comparable to full-gene Table S6.

Widening Linear from 7 kb to 524 kb changed no metric significantly. Linear's Discrimination Cosine stayed at chance level in every cell line at both widths (chance = 5.0), while STRAND reached 7.11-7.23.

Table R1. Linear context control. Combined = mean over K562, Jurkat, RPE1.

Setting Model DiscCos ↑ DirMatch ↑ P@N ↑ O@N ↑ ΔPear ↑ MSE ↓ Rank ↓
Few-shot k=5 Linear 7 kb 5.060 6.774 1.728 1.983 0.293 1.754 1.91
Linear 524 kb 5.046 6.767 1.720 1.970 0.291 1.764 2.86
STRAND 7.159 8.014 2.427 2.626 0.460 1.754 1.22
Zero-shot Linear 7 kb 5.025 7.057 1.801 1.950 0.328 1.720 2.00
Linear 524 kb 5.021 7.058 1.796 1.942 0.327 1.726 2.67
STRAND 5.389 7.981 2.158 2.397 0.457 1.750 1.33

DiscCos, DirMatch, P@N, O@N x10; MSE x100, as in Table 2.

STRAND also holds the best rank in each individual cell line and outranks Linear in every cell line of Table S6 and Table R1. MSE alone does not establish perturbation-prediction quality [1,2]: PerturbMean has the best MSE in Table 2 (1.03) at chance-level DiscCos (5.02).

Ablations. Table S10 changes one component at a time: “w/o Perturbation Module” mean-pools the same Borzoi embeddings instead of using locus-anchored aggregation; “w/o Latent Diffusion” replaces I²SB with an equal-width deterministic predictor. Combined results:

Method DiscCos ↑ E-Dist ↓ DirMatch ↑ P@N ↑ O@N ↑ ΔPear ↑ MSE ↓ Rank ↓
w/o Perturbation Module 5.063 2.340 7.287 0.690 0.960 0.347 1.093 2.24
w/o Latent Diffusion 4.993 3.143 7.307 0.693 0.813 0.357 1.183 2.57
STRAND 7.110 2.037 7.660 0.707 1.150 0.380 0.990 1.19

We will add the Linear control to Appendix J.1 and discuss it in Appendix H. The submission already ablates alignment (S9), transport backbone (S12), and perturbation coordinates (S13).

Summary

All four cost items are now measured, the matched-context Linear control is run, and the Appendix G.2 wording is corrected. We would be grateful if the reviewer would weigh this evidence in the final assessment.

[1] Vinas Torne et al., Nat Biotechnol 2025. [2] Ahlmann-Eltze et al., Nat Methods 2025.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…