Positive-Unlabeled Preference Optimization For Chest X-ray Report Generation
Yuta Kobayashi, Pradyun Ramesh, Muhammad Ahmed Chaudhry, Vincent Jeanselme, Judy Gichoya, Sanmi Koyejo, Kathleen M. Capaccione, Shalmali Joshi
NeurIPS 2026
Abstract. Vision-Language Models (VLMs) for radiology report generation are typically trained on retrospective clinical reports, which suffer from omission noise: clinically present findings are left unreported due to the omission of subtle findings. For example, prior studies show that cardiomegaly may be omitted from ICU chest X-ray reports when the imaging request is focused on monitoring support device placement. As a result, models trained with standard approaches inherit these omissions, learning to under-report findings themselves. We propose PU-DPO, a preference optimization framework that constructs contrastive pairs via editing model responses, producing variants that explicitly mention or omit a specific finding. To prevent omission noise from corrupting the preference signal, we reformulate the objective under a positive-unlabeled (PU) learning framework, treating absent mentions as unlabeled rather than truly negative. Across semi-synthetic experiments and preliminary analyses on real-world chest radiograph benchmarks where adjudicated labels are available, PU-DPO yields consistent gains in detection rates across multiple pathologies without compromising specificity or overall report quality, and is more robust to omission noise than prior approaches.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:43 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
PU-DPO applies a positive-unlabeled correction to DPO for chest X-ray report generation, motivated by the observation that retrospective radiology reports are not exhaustive and unmentioned findings should be treated as unlabeled rather than as negatives. Contrastive report pairs are constructed with a large editor model (GPT-OSS 120B) that differ in whether a target pathology subtype is mentioned, and a PU-risk correction is applied to the DPO-style objective. Experiments include semi-synthetic omission noise on CheXpert and real-world evaluations on CheXpert and MIMIC-CXR across LLaVA-Rad, MedGemma, and NV-Reason.
Please address the following in your response.
-
Real-world validation gap. Most of the real-world evaluation still leans on labels extracted from reports — precisely what the paper critiques as noisy — so omitted-finding recovery is not directly verified (Reviewer MaLq); Reviewers nvdG and eBbw independently ask for a radiologist-adjudicated test set.
-
PU assumptions. SCAR within subtype, no false-positive report mentions, and accurate alpha estimation are unlikely to hold cleanly since omissions depend on ICU status, indication, severity, and co-occurring findings (Reviewer eBbw); Reviewer MaLq asks about sensitivity of real-world results to alpha estimation errors.
-
Editor-pair quality. The method relies heavily on GPT-OSS 120B for constructing contrastive pairs, but edit quality and clinical consistency are not audited enough (Reviewer eBbw, echoed by Reviewer MaLq).
Final justification
During the rebuttal, the authors responded to the concerns raised by the reviewers, and two reviewers accepted the rebuttal in principle. All three reviewers gave positive ratings. Although one reviewer did not provide a final recommendation, I think the authors provided an adequate response.
Read meta-review
Meta-review
PU-DPO applies a positive-unlabeled correction to DPO for chest X-ray report generation, motivated by the observation that retrospective radiology reports are not exhaustive and unmentioned findings should be treated as unlabeled rather than as negatives. Contrastive report pairs are constructed with a large editor model (GPT-OSS 120B) that differ in whether a target pathology subtype is mentioned, and a PU-risk correction is applied to the DPO-style objective. Experiments include semi-synthetic omission noise on CheXpert and real-world evaluations on CheXpert and MIMIC-CXR across LLaVA-Rad, MedGemma, and NV-Reason.
Please address the following in your response.
-
Real-world validation gap. Most of the real-world evaluation still leans on labels extracted from reports — precisely what the paper critiques as noisy — so omitted-finding recovery is not directly verified (Reviewer MaLq); Reviewers nvdG and eBbw independently ask for a radiologist-adjudicated test set.
-
PU assumptions. SCAR within subtype, no false-positive report mentions, and accurate alpha estimation are unlikely to hold cleanly since omissions depend on ICU status, indication, severity, and co-occurring findings (Reviewer eBbw); Reviewer MaLq asks about sensitivity of real-world results to alpha estimation errors.
-
Editor-pair quality. The method relies heavily on GPT-OSS 120B for constructing contrastive pairs, but edit quality and clinical consistency are not audited enough (Reviewer eBbw, echoed by Reviewer MaLq).
Final justification
During the rebuttal, the authors responded to the concerns raised by the reviewers, and two reviewers accepted the rebuttal in principle. All three reviewers gave positive ratings. Although one reviewer did not provide a final recommendation, I think the authors provided an adequate response.
1 comment
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper studies omission noise in chest X-ray report generation: clinical reports are not exhaustive labels, so a finding can be visible on the image but not mentioned in the report. A model trained on such reports may then learn to omit the same findings. The authors propose PU-DPO, which treats missing mentions as unlabeled rather than negative. They create contrastive report pairs that either mention or omit a target finding, then train with a positive-unlabeled version of DPO. The paper evaluates the method in semi-synthetic omission settings and on CheXpert/MIMIC-CXR with several VLM backbones.
Strengths and weaknesses
I think the paper is going after the right problem. The “not mentioned” != “not present” point is very important in radiology, and the paper makes a good case that standard SFT or reward-based training can inherit this bias. The PU-DPO idea is also neat: it is not just another reward tweak, but a principled attempt to fix the label structure behind the preference signal.
The semi-synthetic experiments are the most convincing part. When positives are deliberately hidden, standard DPO becomes too conservative, while PU-DPO keeps sensitivity higher. That is exactly the failure mode the method is supposed to address, and the comparison to Dr-DPO is useful.
The paper is also reasonably well documented. I appreciated the derivation, the alpha sweep, multiple backbones, two datasets, confidence intervals, prompts, and compute details. This is more complete than many papers in this space.
That said, I am not fully convinced by the real-world clinical evidence. The paper’s core claim is that PU-DPO recovers visually present findings that reports omit. But most of the real-world evaluation still uses labels extracted from reports. This leaves a gap, because those reports are precisely what the paper says are incomplete. The radiologist study helps show that omission noise exists, but it does not really validate that PU-DPO produces clinically better reports on omitted-positive cases.
I also want more evidence that the synthetic edited preference pairs are clean. GPT-OSS 120B is carrying a lot of the training signal here. If the edits add artifacts, change unrelated findings, or make the “presence vs absence” contrast too artificial, then the training signal may not mean what the paper says it means. A length filter is not enough to settle that.
The assumptions are another concern. SCAR/multi-SCAR is convenient, but in radiology omissions are probably not random within a subtype. Mild findings, ICU context, support devices, view quality, co-occurring disease, and clinical indication can all affect whether a radiologist mentions something. The paper admits this, but does not really show how much it matters in practice.
Finally, I would tone down the specificity claim. PU-DPO often improves sensitivity/F1, but the tables show specificity drops in some settings. That may be a reasonable clinical tradeoff, but the paper should call it a tradeoff rather than saying specificity is not compromised.
Questions
-
Can you evaluate PU-DPO on a small radiologist-adjudicated subset of generated reports, especially cases where the original report omits a finding that radiologists mark as present?
-
Can you manually audit the GPT-OSS edited preference pairs? I would like to know how often the edits are clinically valid, preserve unrelated findings, and correctly express the target subtype.
-
How sensitive are the real-world results to alpha estimation errors? The semi-synthetic sweep is useful, but the real setting is the important one.
-
Could you state the specificity result as a sensitivity-specificity tradeoff where appropriate? Some results do show specificity degradation.
-
Can you clarify how to interpret real-world gains measured against report-derived labels, given that the paper’s premise is that report-derived labels are noisy?
Limitations
The current limitations section covers alpha estimation and SCAR, which is good, but it misses several practical issues. I would add the lack of direct radiologist evaluation of generated reports, dependence on GPT-OSS edits, limited pathology/subtype coverage, single-seed reporting, and the fact that sensitivity gains sometimes come with specificity loss.
Final justification
The authors substantially addressed my concerns by adding an evaluation on the radiologist-adjudicated CheXpert test set, real-world sensitivity analysis for alpha, a radiologist audit of the GPT-OSS contrastive edits, and pathology-specific results.
The edit audit suggests that the editor usually performs the requested operation and preserves unrelated findings, although only 62/70 pairs were judged definitively clinically correct. More importantly, the pathology-specific analysis shows that PU-DPO helps recover omitted atelectasis findings but does not improve over standard DPO for cardiomegaly, where the authors detect a statistically significant SCAR violation. This is a useful and honest result, but it also shows that the method’s real-world benefit depends strongly on its assumptions.
The adjudicated-alpha variants are oracle/post-hoc analyses, while the deployable BBE results remain mixed across backbones. Sensitivity gains also sometimes come with lower specificity. I therefore remain positive about the problem formulation, method, and semi-synthetic evidence, but retain a Borderline Accept rating rather than moving to a clear Accept.
Formatting concerns
No
6 comments
Rebuttal
We thank the reviewer for their careful reading and thoughtful questions, which allowed us to further clarify and improve our empirical evaluations.
[Q1] Evaluation on adjudicated test set. Please refer to the response for reviewer nvDG [Q2].
[Q2] Auditing contrastive edits. We have created a study for manually auditing the contrastive edits and will include study results with a radiologist in the camera-ready version. In the study, we evaluate the correctness of the edit, the preservation of unrelated findings, and the clinical correctness of the preferred response using the Medgemma base responses, where edits are introduced by GPT-OSS 120B to the on-policy response.
[Q3] Sensitivity to in real-world settings. We conducted a sensitivity analysis on the real-world radiologist-adjudicated test set and found that the real-world results mirror our semi-synthetic findings. Please refer to the response for reviewer nvDG [Q2] for the result table.
While underestimating dampens the maximum theoretical benefit of PU-DPO, it still often outperforms both standard DPO and the base model in recall and omission recovery. Crucially, our PU-DPO objective modifies the standard DPO objective purely through an -scaled loss correction term. This allows us to interpret as a calibration parameter for the diagnostic threshold, explicitly managing the sensitivity-specificity tradeoff. Therefore, if a training dataset is known to contain hidden positives, using a conservatively estimated (e.g., the empirical prevalence of labeled positives plus a small ) may provide a safe and effective strategy for recovering them in practice.
[Q4] Specificity degradation. We acknowledge the decrease in specificity compared to the base model in certain settings, and we will update the text to explicitly characterize this as a necessary sensitivity-specificity trade-off. We note that a base model that systematically underdiagnoses will naturally exhibit an artificially inflated specificity, simply because it overwhelmingly defaults to predicting the negative class.
[Q5] Evaluating against noisy report-derived labels. We address the noise in report-derived labels by strictly filtering the evaluation dataset to contain only labeled positives and labeled negatives (where the original report explicitly noted the absence of the pathology). By testing models on this curated distribution, we can evaluate their underlying diagnostic accuracy on a sufficiently large set of real images with known pathology presence. However, this setup likely introduces a distribution shift and does not directly evaluate the recovery of hidden positives. Therefore, we now additionally report results on a test-sample with radiologist-adjudicated labels (see [Q1]) which we will include in the main text of our revised manuscript.
Thank you for the detailed response. I read the adjudicated-set results and the responses to the other reviewers. The new evaluation addresses an important part of my concern, and I appreciate that the paper now describes the result as a sensitivity-specificity trade-off rather than a uniform improvement.
Two points remain important to me.
First, the audit of the GPT-OSS edits is currently promised only for the camera-ready version. Since these edits provide the central training signal, could you report the current audit sample size, protocol, and preliminary results during the discussion? A short table with the rates of correct target edits, preservation of unrelated findings, and clinical validity would be sufficient.
Second, your SCAR analysis finds a statistically significant violation for cardiomegaly (p=0.016). Could you report the adjudicated results separately for each pathology, especially omission recovery and specificity for cardiomegaly? This would show how the method behaves when one of its main assumptions is detectably violated.
Please also make clear that the adjudicated-alpha variants use test-set information and are therefore oracle/post-hoc sensitivity analyses rather than deployable estimates. The BBE-alpha variant should remain the primary real-world result.
The new results are encouraging, particularly for MedGemma, but they are mixed across backbones and several confidence intervals overlap. I therefore agree with the authors’ more cautious interpretation and ask that the final paper avoid claims of consistent improvement without a specificity cost.
We thank the reviewer for their detailed analysis of the results and helpful feedback, and we agree that these points are important to address.
[Q1] Study results on contrastive edits. We provide preliminary results from an initial sample evaluated by a board-certified radiologist to determine whether our editor LLM correctly introduces the targeted pathology subtypes. A radiologist reviewed a random subset of 70 MedGemma preference pairs (35 for pleural effusion and 35 for cardiomegaly). We found that:
-
Edit accuracy: The target edit operations (addition and removal) were performed correctly in 68/69 cases (1 missing response).
-
Context preservation: Unrelated findings were successfully preserved in 67/69 cases (1 missing response).
-
Clinical correctness: The preferred response was definitively correct in 62/70 cases (4 cases were uncertain, and 4 were incorrect).
Error analysis: The 8 uncertain or incorrect cases stemmed from disagreements with the original retrospective reports. The original reporting radiologists likely had access to lateral views, allowing for definitive diagnoses in subtle cases of pleural effusion and cardiomegaly, whereas our study was restricted to single frontal views. We acknowledge this reliance on single-view imaging as a limitation, and reliance on single-view imaging for report generation is a broader limitation that most state-of-the-art report generation models suffer from. Because retrospective reports rely on all available views, we leave such extensions to future work.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 4/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposes PU-DPO, a positive-unlabeled variant of direct preference optimization for chest X-ray report generation. The core motivation is that retrospective radiology reports often omit true visual findings, so treating unmentioned findings as negatives can train VLMs to under-report disease. The method constructs contrastive report pairs that mention vs. omit a target pathology subtype, then applies a PU-risk correction using a class prior estimate. Experiments include semi-synthetic omission noise on CheXpert and real-world evaluations on CheXpert and MIMIC-CXR across LLaVA-Rad, MedGemma, and NV-Reason.
Strengths and weaknesses
Strengths
- The problem is important and well-motivated: omission noise is a real issue in clinical report supervision.
- The PU framing is natural and technically clean, with a clear derivation connecting PU risk estimation to DPO-style preference optimization.
- The semi-synthetic experiments are useful and show the expected failure mode of naive DPO under increasing hidden-positive rates.
- Evaluation covers multiple datasets, multiple VLM backbones, and several clinical metrics rather than relying only on surface text similarity.
Weaknesses
- The central assumptions are strong. SCAR within subtype, no false-positive report mentions, accurate label extraction, and accurate alpha estimation are unlikely to hold cleanly in real clinical reports.
- The method relies heavily on a large external editor model for constructing contrastive pairs, but edit quality, failure modes, and clinical consistency are not audited deeply enough.
- Only three pathologies and seven fine-grained subtypes are studied, limiting the claim of broad applicability.
Questions
-
How robust is PU-DPO when SCAR is violated, for example when omissions depend on ICU status, report indication, disease severity, or co-occurring findings?
-
Can the authors evaluate on a held-out radiologist-adjudicated test set rather than labels extracted from the same noisy report distribution?
-
How often does the GPT-OSS 120B editor introduce clinically incorrect additions/removals?
-
Does the method scale to more findings and richer subtypes beyond the three pathologies and seven subtypes studied here?
Limitations
yes
Formatting concerns
None
2 comments
Rebuttal
We thank the reviewer for their careful reading and thoughtful questions, allowing us to clarify and discuss key assumptions.
[Q1] Multi-SCAR assumption. Intuitively, the multi-SCAR assumption dictates that labeled positives are a representative subsample of all true positives for a particular disease subtype. When this assumption is violated, for instance, if a certain finding is systematically reported only for ICU patients but present in both the ICU and ED, a distribution mismatch may occur between the labeled positives and the unlabeled hidden positives. Consequently, PU-DPO's reliance on labeled positive samples as a proxy for hidden positives breaks down.
While our paper considers disease severity as an omission factor, a practical solution to selection bias is defining even finer subtypes for (e.g., "mild cardiomegaly in the ICU") to isolate unbiased subpopulations given sufficient training data. The validity of these subtypes can then be verified by collecting adjudicated labels for a representative subset of the data.
We demonstrate this verification process at the pathology level using our radiologist-adjudicated test set. To test for statistical independence between labeled and hidden positives, we extracted MedGemma image embeddings and evaluated the cohorts using a kernel MMD test, with corresponding p-values. As shown in the table below, Cardiomegaly exhibits detectable selection bias (violating SCAR) with statistical significance, whereas Atelectasis and Pleural Effusion show indistinguishable distributions, indicating that the SCAR assumption may hold.
| Finding | Labeled | Hidden | MMD$^2$ | MMD |
|---|---|---|---|---|
| Cardiomegaly | 46 | 102 | 0.0079 | 0.016 |
| Atelectasis | 73 | 80 | -0.0040 | 0.979 |
| Pleural Effusion | 80 | 20 | -0.0081 | 0.940 |
Table: SCAR check on the radiologist-adjudicated CheXpert test set. For each finding, labeled positives (the original report asserts the finding) are compared against hidden positives (the report excludes but the adjudicating radiologists confirmed the finding) in MedGemma image-embedding space. Under SCAR the two cohorts are assumed as draws from the same distribution, so the kernel-MMD permutation test should not reject and the cross-validated labeled-vs-hidden; -values are permutation tails over 5000 resamples.
[Q2] Evaluation on adjudicated test set. Please refer to the response for reviewer nvDG [Q2].
[Q3] Auditing contrastive edits. We have created a study for manually auditing the contrastive edits and will include study results with a radiologist in the camera-ready version. In the study, we evaluate the correctness of the edit, the preservation of unrelated findings, and the clinical correctness of the preferred response using the Medgemma base responses, where edits are introduced by GPT-OSS 120B to the on-policy response.
[Q4] Generalizability. We expect that applying a PU correction to DPO will generalize to other chest radiography pathologies and subtypes, as our underlying assumptions rely on the overall noise structure of chest radiograph reports rather than disease-specific features. In this study, we provide a proof-of-concept using well-studied pathologies; due to computational constraints, scaling this to a fully fine-tuned report generation model remains future work. Furthermore, extending this method to other imaging modalities will depend heavily on their respective reporting noise models. For instance, mammography utilizes much more rigid reporting constraints than chest radiography, potentially requiring different noise assumptions. We consider this an important avenue for future research, and acknowledge this as a limitation of the current study.
[Q3 Followup] Auditing contrastive edits. We provide preliminary results from an initial sample evaluated by a board-certified radiologist to determine whether our editor LLM correctly introduces the targeted pathology subtypes. A radiologist reviewed a random subset of 70 MedGemma preference pairs (35 for pleural effusion and 35 for cardiomegaly). We found that:
-
Edit accuracy: The target edit operations (addition and removal) were performed correctly in 68/69 cases (1 missing response).
-
Context preservation: Unrelated findings were successfully preserved in 67/69 cases (1 missing response).
-
Clinical correctness: The preferred response was definitively correct in 62/70 cases (4 cases were uncertain, and 4 were incorrect).
Error analysis: The 8 uncertain or incorrect cases stemmed from disagreements with the original retrospective reports. The original reporting radiologists likely had access to lateral views, allowing for definitive diagnoses in subtle cases of pleural effusion and cardiomegaly, whereas our study was restricted to single frontal views. We acknowledge this reliance on single-view imaging as a limitation, and reliance on single-view imaging for report generation is a broader limitation that most state-of-the-art report generation models suffer from. Because retrospective reports rely on all available views, we leave such extensions to future work.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper addresses an important problem in medical report generation: findings that are not mentioned in clinical reports should not necessarily be treated as reliable negative labels, as they may instead correspond to unlabeled positive findings. This is an interesting and practically important problem. To address it, the authors propose PU-DPO, a preference optimization framework based on positive-unlabeled learning that corrects the training objective for hidden positives.
Strengths and weaknesses
Strengths
- The paper identifies an important limitation of training radiology report-generation models using retrospective clinical reports.
- Treating explicitly mentioned findings as positive and unmentioned findings as unlabeled is a natural formulation of this problem.
- The method constructs preference pairs that differ primarily in whether a specific pathology subtype is included or omitted.
Weaknesses
- The theoretical formulation defines the class prior as the overall prevalence (P(Y=1)), whereas parts of the experimental description appear to interpret the estimated value as the proportion of hidden positives within the unlabeled subset, (P(Y=1 \mid S=-1)).
- The real-world evaluation does not directly verify recovery of omitted findings.
Questions
Could the authors clarify whether the estimated class prior corresponds to the marginal prevalence (P(Y=1)) or the hidden-positive proportion within the unlabeled subset (P(Y=1 \mid S=-1)), and how this estimate is used in the PU-DPO objective? Could the authors evaluate whether PU-DPO directly recovers findings that were omitted from the original reports but confirmed as present by radiologists?
Limitations
The paper appropriately acknowledges its dependence on accurate class-prior estimation and the potentially restrictive multi-SCAR assumption. However, the limitations of relying on automatically generated contrastive edits and the lack of direct radiologist validation of the recovered omitted findings should be discussed more explicitly. In addition, the evaluation is limited to chest X-rays and a small set of pathologies, so the generalizability to other medical imaging domains remains unclear.
Final justification
They address my concerns, so I will increase my score accordingly.
Formatting concerns
N/A
2 comments
Rebuttal
We thank the reviewer for their careful reading and constructive feedback on the study’s limitations and clarity.
[Q1] Alpha estimation. We use the BBE mixture proportion method to estimate the fraction of hidden positives strictly within the unlabeled set, . Because our setup follows the one-sample PU learning setting, this fraction does not equal the overall class prior . Therefore, for each batch, we compute the empirical prior (estimating ) by combining the known labeled positives () with the estimated hidden positives from the unlabeled set (). Specifically, we compute , where is the total batch size. This batch-level is then used to scale the PU loss correction. We will revise the experimental description by providing the step-by-step procedure, and revising Appendix table 8 to be more precise.
[Q2] Evaluation on adjudicated test set. We use the Chexpert test set (500 studies labeled by 5 radiologists), which serves as a radiologist adjudicated set that is also in-distribution (same institution) but unseen for our finetuned model. While the original reports are unavailable for these studies, the report-derived Chexbert labels are publicly available, so we evaluate recovery on hidden positives by treating the provided labels as the noisy diagnosis in the original radiologist report. We first report the statistics of this test set of 500 frontal images.
| Pathology | Positive | Prevalence | Hidden positive |
|---|---|---|---|
| Cardiomegaly | 151 | 30.2% | 102 |
| Atelectasis | 153 | 30.6% | 80 |
| Pleural Effusion | 104 | 20.8% | 20 |
Table: Per-pathology statistics of the radiologist-adjudicated CheXpert test set (500 studies). Prevalence is the fraction of studies the adjudicating radiologists labeled positive. Hidden positives are radiologist-positive studies whose original clinical report never mentioned the finding (blank CheXbert label); they form the denominator of the omission-recovery metric.
As a potentially more distributionally aligned alternative to BBE, we compute an "adjudicated ." This approach derives the hidden positive rate directly from the marginal empirical frequencies in our adjudicated test set. We then estimate the subtype conditional probability using the empirical frequencies in the CheXpert training set. For our sensitivity analysis, we perturb this adjudicated by to simulate over- and under-estimation.
Below are results comparing the base model, standard DPO, and our PU variants with different choices of on various metrics:
| Backbone | Method | Micro-F1 ↑ | Micro recall ↑ | Micro specificity ↑ | Omission recovery ↑ |
|---|---|---|---|---|---|
| MedGemma-4B | Base | 0.615 [0.571, 0.653] | 0.647 [0.598, 0.693] | 0.829 [0.803, 0.851] | 0.553 [0.486, 0.626] |
| DPO | 0.619 [0.580, 0.658] | 0.686 [0.644, 0.727] | 0.802 [0.776, 0.826] | 0.620 [0.554, 0.684] | |
| PU-DPO (BBE ) | 0.635 [0.598, 0.672] | 0.723 [0.683, 0.761] | 0.793 [0.765, 0.818] | 0.650 [0.589, 0.713] | |
| PU-DPO (Adjudicated ) | 0.638 [0.599, 0.675] | 0.722 [0.679, 0.761] | 0.798 [0.772, 0.822] | 0.655 [0.594, 0.717] | |
| PU-DPO (Adjudicated ) | 0.632 [0.593, 0.670] | 0.719 [0.676, 0.760] | 0.792 [0.765, 0.817] | 0.659 [0.595, 0.723] | |
| PU-DPO (Adjudicated ) | 0.629 [0.590, 0.668] | 0.701 [0.659, 0.742] | 0.803 [0.777, 0.826] | 0.651 [0.589, 0.716] | |
| NV-Reason-CXR-3B | Base | 0.707 [0.671, 0.739] | 0.830 [0.796, 0.864] | 0.806 [0.779, 0.832] | 0.767 [0.712, 0.825] |
| DPO | 0.718 [0.684, 0.750] | 0.827 [0.790, 0.862] | 0.822 [0.795, 0.846] | 0.795 [0.736, 0.851] | |
| PU-DPO (BBE ) | 0.710 [0.673, 0.743] | 0.820 [0.785, 0.856] | 0.816 [0.789, 0.842] | 0.763 [0.707, 0.821] | |
| PU-DPO (Adjudicated ) | 0.708 [0.674, 0.739] | 0.825 [0.791, 0.860] | 0.811 [0.784, 0.835] | 0.797 [0.742, 0.850] | |
| PU-DPO (Adjudicated ) | 0.712 [0.679, 0.742] | 0.830 [0.797, 0.864] | 0.812 [0.785, 0.838] | 0.801 [0.748, 0.853] | |
| PU-DPO (Adjudicated ) | 0.709 [0.674, 0.743] | 0.832 [0.795, 0.867] | 0.808 [0.779, 0.833] | 0.795 [0.739, 0.848] | |
| LLaVA-Rad | Base | 0.654 [0.611, 0.692] | 0.694 [0.647, 0.737] | 0.840 [0.815, 0.862] | 0.574 [0.503, 0.643] |
| DPO | 0.621 [0.583, 0.656] | 0.672 [0.628, 0.712] | 0.816 [0.790, 0.840] | 0.569 [0.500, 0.635] | |
| PU-DPO (BBE ) | 0.611 [0.572, 0.646] | 0.706 [0.665, 0.749] | 0.775 [0.747, 0.801] | 0.604 [0.546, 0.665] | |
| PU-DPO (Adjudicated ) | 0.629 [0.590, 0.662] | 0.713 [0.672, 0.751] | 0.793 [0.768, 0.820] | 0.619 [0.559, 0.680] | |
| PU-DPO (Adjudicated ) | 0.625 [0.587, 0.658] | 0.711 [0.671, 0.748] | 0.789 [0.763, 0.816] | 0.614 [0.549, 0.678] | |
| PU-DPO (Adjudicated ) | 0.624 [0.586, 0.656] | 0.689 [0.649, 0.729] | 0.806 [0.782, 0.832] | 0.599 [0.530, 0.665] |
Table: Results on the radiologist-adjudicated CheXpert test set. Omission recovery is the rate at which a model reports a finding that the original clinical report omitted but the adjudicating radiologists confirmed as present (i.e. recovery of hidden positives). 95% bootstrap CIs in brackets.
Interpretation. We interpret the results as follows. Because PU-DPO is exactly our DPO baseline plus a -scaled PU loss correction term, the choice of effectively acts as a calibration factor. It dictates the extent to which the VLM shifts its internal diagnostic threshold, controlling the trade-off between sensitivity and specificity. Our underlying DPO approach aims to teach the model to better capture pathology signals, monotonically improving both sensitivity and specificity in some cases (as seen in our semi-synthetic results). PU-DPO builds on this as a well-specified calibrates the model to maintain sensitivity when faced with hidden positives in training, without sacrificing the benefits of DPO. Therefore, while we demonstrate evidence of the intended effect of increased omission recovery on the adjudicated hidden positives, we cannot yet conclude with statistical certainty that our finetuned models yield consistent improvements on all metrics across a broader clinical deployment distribution.
[L1] Limitations. We will acknowledge these limitations more carefully. On the reliance on automated preference data construction for our empirical validation, we have created a study for manually auditing the contrastive edits and will include study results with a radiologist in the camera-ready version, where we evaluate the correctness of the edit, the preservation of unrelated findings, and the clinical correctness of the preferred response. We will also acknowledge the limitation regarding the small data size of the adjudicated test set and interpret the results cautiously.
Thank you for the more detailed results and clarifications. They address my concerns, so I will increase my score accordingly.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
We thank the AC for a detailed meta-review that states precisely what the paper needs to address. We summarize the rebuttal process below:
Adjudicated test-set evaluation. We present empirical validation using an adjudicated test set (Reviewer nvDG [Q2]), demonstrating PU-DPO's intended effect on hidden positive recovery. We further break this down into pathology-specific results (Reviewer MaLq Followup), showing that real-world effectiveness may closely depend on the pathology-wise SCAR assumption.
Sensitivity Analysis & SCAR. We conduct an α sensitivity analysis using real-world data (Reviewer nvDG [Q2]) to illustrate how the choice of α effectively acts as a calibration factor, dictating the extent to which the model shifts its internal diagnostic threshold. We also include hypothesis testing to verify the SCAR assumption against the adjudicated test set (Reviewer eBbw [Q1]). Our analysis indicates that further radiologist adjudication is a highly promising avenue to test these assumptions and elicit α.
Edit quality audit study. We conducted a new study with a radiologist to audit the preference pairs. The results (Reviewers eBbw, MaLq Followup) demonstrate high edit quality and confirm the preservation of unrelated findings for our experiments.
We hope that these changes have addressed concerns, and we thank you again for your time and consideration.