potentialpaper

Anchored Inertial Proposals with Objective Verification for Diffusion-Prior Inverse Problems

Minwoo Kim, Seunghyeok Shin, Dabin Kim, Hongki Lim

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

Abstract. Training-free diffusion priors are powerful for inverse problems, but measurement guidance during reverse sampling is local: aggressive updates can improve immediate data fit while disrupting later denoising. We introduce an anchored inertial correction rule that separates proposal generation from acceptance. At each corrected step, the denoiser prediction anchors a frozen clean-space objective combining measurement fit with a noise-level-dependent proximal term. Heavy-ball dynamics with step size and momentum computed from the measured curvature generate a clean-state candidate; a separate verifier evaluates it with the same objective, with the denoiser prediction retained as fallback; both stages are derived from one objective for the whole trajectory, considered one step at a time. The accepted clean state is re-noised to continue sampling. The rule applies to pixel and latent diffusion with differentiable measurement operators, requires no retraining, and adds no denoiser calls inside the correction loop. We analyze how objective verification yields local nonincrease and displacement control. Across natural-image benchmarks, the method achieves competitive reconstruction quality. Code is available at https://github.com/Seunghyeok0715/PIVOT2026.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
5 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]—[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:43 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

The paper proposes PIVOT, a training-free diffusion-based inverse solver that integrates several components (e.g., tethered denoising, heavy-ball proposal generation, etc.). The reviewers recognized several strengths of the work, including the importance of the problem, the novel algorithmic pipeline, and competitive experimental performance on certain inverse problems. While the method largely builds on existing techniques and the theoretical analysis is limited, the authors addressed most concerns well in the rebuttal. Overall, the method offers clear practical value and constitutes a solid contribution.

Final justification

Overall, the practical value overrides the concern on sampling theory, which justifies my recommendation for acceptance.

Area Chair vcwS · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

The paper proposes PIVOT, a training-free diffusion-based inverse solver that integrates several components (e.g., tethered denoising, heavy-ball proposal generation, etc.). The reviewers recognized several strengths of the work, including the importance of the problem, the novel algorithmic pipeline, and competitive experimental performance on certain inverse problems. While the method largely builds on existing techniques and the theoretical analysis is limited, the authors addressed most concerns well in the rebuttal. Overall, the method offers clear practical value and constitutes a solid contribution.

Final justification

Overall, the practical value overrides the concern on sampling theory, which justifies my recommendation for acceptance.

Reviewer 1TKUOpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes PIVOT, a training-free correction rule for solving inverse problems with pretrained diffusion priors. Existing diffusion sampling methods directly inject measurement gradients in reverse steps, which easily destabilize denoising trajectories and hurt reconstruction quality. The proposed two-part design separates candidate generation and objective verification: heavy-ball inertial steps plus predictive smoothing generate candidate clean states, then a frozen unsmoothed objective filters candidates and retains the denoiser prediction as fallback, avoiding harmful large updates. The method works for both pixel and latent diffusion, and full theoretical derivations of local contraction and bound properties are provided in appendices.

Strengths and weaknesses
  1. Clear novel decoupling design, solving the stability defect of direct measurement guidance in diffusion sampling.
  2. Complete theoretical analysis proving local objective non-increase and displacement control properties, rigorous mathematical support.
  3. Comprehensive experiments covering natural image tasks (inpainting, deblurring, HDR etc.) and fastMRI medical reconstruction, with full ablation and hyperparameter analysis verifying each component’s contribution.
  4. Favourable speed-quality balance compared to mainstream baselines like DAPS, FAST-DIPS, achieving state-of-the-art PSNR on undersampled MRI data.
Questions
  1. The theoretical guarantees only hold per single reverse step, without global convergence analysis for the full sampling trajectory; add discussion on long-term trajectory stability.
  2. Experiments only test differentiable forward operators; supplement tests on non-differentiable measurement models to show generalizability.
  3. The paper mentions hallucination risks for medical imaging but lacks targeted quantitative analysis of reconstruction artifacts under severe undersampling.
Limitations

I would encourage the authors to more explicitly discuss the local nature of the theoretical guarantees, the number of task-dependent hyperparameters, and the fact that PIVOT is not uniformly better than all baselines across natural-image metrics. The current results support a favorable trade-off claim, but not universal superiority.

Formatting concerns

None.

2 comments
Authors · CommentOpenReview ↗

Rebuttal by Authors (1/2)

Thank you for the constructive review. We appreciate the questions on trajectory stability, non-differentiable measurements, and severe MRI undersampling. This review became visible to us on 3 August 2026, and we are responding at the earliest opportunity.

Q1. Long-term trajectory stability

We agree that a per-step guarantee alone does not quantify how accepted corrections propagate. We will add the following conditional result.

Theorem (finite-horizon perturbation propagation and conditional long-term tracking). Let Dk:=DσkD_ k:=D_ {\sigma_ k}, μk=Dk(uk)\mu_ k=D_ k(u_ k), and Δk=zk+−μk\Delta_ k=z_ k^+-\mu_ k, with Δk=0\Delta_ k=0 when correction is skipped:

uk+1=Dk(uk)+Δk+σk+1ϵk.u_ {k+1}=D_ k(u_ k)+\Delta_ k+\sigma_ {k+1}\epsilon_ k.

Couple this with the uncorrected reference trajectory using the same Gaussian innovations:

vk+1=Dk(vk)+σk+1ϵk,v0=u0.v_ {k+1}=D_ k(v_ k)+\sigma_ {k+1}\epsilon_ k,\qquad v_ 0=u_ 0.

If DkD_ k is ckc_ k-Lipschitz on the coupled states, then, for every T≤KT\le K,

∥uT−vT∥2≤∑k<T(∏r=k+1T−1cr)∥Δk∥2≤∑k<T(∏r=k+1T−1cr)2Rkβk,\|u_ T-v_ T\|_ 2\le \sum_ {k<T}\left(\prod_ {r=k+1}^{T-1}c_ r\right)\|\Delta_ k\|_ 2 \le \sum_ {k<T}\left(\prod_ {r=k+1}^{T-1}c_ r\right) \sqrt{\frac{2R_ k}{\beta_ k}},

where L(z):=ℓ(F(z),y)L(z):=\ell(F(z),y), Rk:=L(μk)−L(zk+)+ηk≥0R_ k:=L(\mu_ k)-L(z_ k^+)+\eta_ k\ge0, βk>0\beta_ k>0 is the tether weight, ηk≥0\eta_ k\ge0 is the selection slack, and an empty product is one. The second inequality follows from verified displacement control.

This is a pathwise bound under a same-noise coupling. It bounds each accepted correction's propagated contribution relative to the uncorrected sampler; without contractivity, the products of ckc_ k explicitly expose possible amplification rather than guaranteeing decay. If the coupled recursion is extended indefinitely, ck≤c<1c_ k\le c<1, and ∥Δk∥2≤d\|\Delta_ k\|_ 2\le d, then sup⁡T∥uT−vT∥2≤d/(1−c)\sup_ T\|u_ T-v_ T\|_ 2\le d/(1-c); if additionally ∥Δk∥2→0\|\Delta_ k\|_ 2\to0, then ∥uT−vT∥2→0\|u_ T-v_ T\|_ 2\to0. An LGL_ G-Lipschitz decoder/output map multiplies the image-space bound by LGL_ G.

Because fresh noise is intentionally injected, monotonicity of noisy states is neither expected nor required. This result does not establish contraction toward x⋆x^\star, monotonicity of a global objective, distributional/posterior convergence, global optimality, or calibrated posterior sampling. We will include the formal statement and proof in the revision.

Q2. Non-differentiable measurement operators

PIVOT requires gradients through the sampling-time composite map F=A∘GF=A\circ G, so direct use with a genuinely non-differentiable operator is an explicit scope limitation. In exact JPEG, hard quantization has zero derivative almost everywhere and is non-differentiable at thresholds, eliminating a meaningful proposal gradient.

We tested the practically relevant surrogate setting on 10 FFHQ images at JPEG quality q=10q=10. In both rows, measurements were generated by the same exact pipeline, y=AJPEGexact(x⋆)y=A_ {\mathrm{JPEG}}^{\mathrm{exact}}(x^\star); only the sampling-time operator changed.

Sampling-time operator PSNR SSIM LPIPS
Exact JPEG 10.850 0.392 0.697
Differentiable JPEG surrogate [1] 30.066 0.853 0.248

Exact JPEG performs poorly because quantization yields vanishing gradients, whereas the differentiable surrogate substantially improves all three metrics despite exact-JPEG measurements. The supported conclusion is deliberately narrow: this demonstrates feasibility for exact-JPEG measurements when a sufficiently faithful differentiable surrogate is available during sampling. It does not establish direct applicability to arbitrary non-differentiable operators. The local verification guarantee is then with respect to the surrogate objective; performance under the exact-JPEG mismatch is empirical. We will add this experiment and clarify the scope.

[1] C. Reich, B. Debnath, D. Patel, and S. Chakradhar, “Differentiable JPEG: The Devil is in the Details,” WACV 2024.

Authors · CommentOpenReview ↗

Rebuttal by Authors (2/2)

Q3. Artifact-sensitive evaluation under severe undersampling

We extended the same 96-slice fastMRI protocol to 16×16\times undersampling. We transferred the submitted 8×8\times configurations without acceleration-specific retuning and used identical masks and random seeds across methods.

Method PSNR ↑\uparrow SSIM ↑\uparrow EacqE_ {\mathrm{acq}} ↓\downarrow EgnullE_ {\mathrm{gnull}} ↓\downarrow HFEN ↓\downarrow WD-EgnullE_ {\mathrm{gnull}} ↓\downarrow
DAPS 26.40 0.5935 0.1436 0.0558 0.7795 0.1749
DDS 25.31 0.5502 0.1428 0.0526 0.8553 0.1361
FAST-DIPS 26.76 0.5104 0.1460 0.0364 0.7022 0.0883
PIVOT 27.29 0.5452 0.1420 0.0349 0.6603 0.0870

PSNR measures overall image-domain fidelity but does not isolate weakly constrained components. The acquired-data residual

Eacq=∥Ax^−y∥2/∥y∥2E_ {\mathrm{acq}}=\|A\hat{x}-y\|_ 2/\|y\|_ 2

measures consistency with acquired measurements, but cannot detect errors in poorly observed directions. The generalized null-space error

Egnull=∥Pgnull(x^−x⋆)∥22/∥x⋆∥22,Pgnull=I−Aϵ†A,E_ {\mathrm{gnull}}=\|P_ {\mathrm{gnull}}(\hat{x}-x^\star)\|_ 2^2/\|x^\star\|_ 2^2,\qquad P_ {\mathrm{gnull}}=I-A_ \epsilon^\dagger A,

measures error in directions not stably determined by the data and thus more prior-dependent. We use the same per-block relative singular-value threshold ϵ=10−3\epsilon=10^{-3} for every slice and method, retaining σi/σmax⁡,block≥ϵ\sigma_ i/\sigma_ {\max,\mathrm{block}}\ge\epsilon. HFEN compares high-frequency content after a fixed Laplacian-of-Gaussian filter. WD-EgnullE_ {\mathrm{gnull}} is the mean EgnullE_ {\mathrm{gnull}} over the worst 10% of slices.

Under this zero-retuning 16×16\times transfer protocol, PIVOT has the best observed mean PSNR, EacqE_ {\mathrm{acq}}, EgnullE_ {\mathrm{gnull}}, HFEN, and WD-EgnullE_ {\mathrm{gnull}} among the reported methods; DAPS has the best SSIM. The worst-decile ordering is also favorable, although the margin over FAST-DIPS is small (0.0870 vs. 0.0883), so we treat it as descriptive rather than evidence of a statistically established worst-case gain. These are artifact-sensitive reconstruction diagnostics, not a clinical hallucination or diagnostic-impact analysis. We will state this distinction and retain the broader medical-imaging caution in the revision.

Limitations

We agree and will make the qualifications more prominent. The submitted theory is local to the frozen objective at one reverse step. It does not imply monotonicity of noisy states, unconditional global convergence, contraction toward x⋆x^\star, monotonicity of a global objective, or calibrated posterior sampling. Q1 adds only a pathwise same-noise coupling bound relative to an uncorrected reference trajectory under local Lipschitz assumptions; it characterizes propagation of accepted corrections, not those stronger properties.

We also conducted a preliminary paired FFHQ-10 parameter-transfer study using a fixed rule derived from the submitted configurations, rather than choosing shared values from the outcomes.

Task Shared schedule Shared schedule + smoothing
Random inpainting -0.130 -0.130
HDR -0.304 -0.849
Phase retrieval -0.366 -0.366
Latent 4×4\times SR -0.128 -0.128
Mean -0.232 -0.368
Worst task -0.366 -0.849

Values are PSNR changes (dB) from the submitted settings. Shared schedule ties (ρα,γ,spp)(\rho_ \alpha,\gamma,s_ {\mathrm{pp}}) separately within pixel and latent spaces. Shared schedule + smoothing also ties (cpp,τmax⁡)(c_ {\mathrm{pp}},\tau_ {\max}), leaving (K,J,α0)(K,J,\alpha_ 0) task-specific. The first setting provides preliminary evidence that several schedule parameters can be shared with modest PSNR degradation; tying smoothing parameters causes a larger HDR loss. This study covers only four tasks, ten images, and PSNR, while (K,J)(K,J) remain task-specific compute-quality budgets and α0\alpha_ 0 remains task-sensitive. It therefore does not establish a universal configuration.

Finally, PIVOT is not uniformly superior across natural-image PSNR, SSIM, LPIPS, or runtime. We will consistently claim a favorable speed-quality trade-off and Pareto-competitive performance, not universal superiority.

Reviewer bShxOpenReview ↗
Rating
3/6
Confidence
3/5
Quality
3/4
Clarity
2/4
Significance
3/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes PIVOT, a training-free diffusion inverse solver that combines denoiser tethering, heavy-ball proposal generation, predictive smoothing, and objective verification. The method separates candidate generation from acceptance: smoothed and inertial updates generate clean-state proposals, while the original unsmoothed frozen objective verifies whether they should be reinserted into the reverse diffusion trajectory. The approach is clearly formulated and achieves competitive speed–quality trade-offs across natural-image and fastMRI reconstruction tasks. However, the core novelty appears mostly combinational, the theoretical guarantees are limited to local per-step frozen objectives, and the method relies on many task-specific hyperparameters.

Strengths and weaknesses

Strengths

  1. The method has a clear and coherent design. Separating proposal generation from objective verification is a sensible way to stabilize measurement-guided diffusion sampling.
  2. The experiments cover a reasonably broad set of settings, including pixel diffusion, latent diffusion, FFHQ, ImageNet, multiple image inverse problems, and fastMRI reconstruction.
  3. The empirical results are practically competitive. PIVOT performs well on random inpainting, HDR recovery, several latent deblurring settings, and fastMRI PSNR, mainly showing a favorable speed–quality trade-off.

Weaknesses

  1. The core novelty is somewhat incremental. The main components—quadratic tethering, momentum, smoothing, backtracking-style verification, and re-noising—are all closely related to existing optimization or diffusion inverse-problem techniques.
  2. The theoretical contribution is mostly local. The analysis shows per-step nonincrease, contraction, and displacement control for the frozen objective, but it does not imply monotonic improvement of the full diffusion trajectory, global reconstruction optimality, or calibrated posterior sampling.
  3. The method appears to require substantial task-specific tuning. Different tasks use different values of K,J,α0,ρα,γ,cpp,τmax⁡K, J, \alpha_0, \rho_\alpha, \gamma, c_{pp}, \tau_{\max}, and smoothing stride, and the proposal step size is reported to be sensitive.
Questions
  1. How much of PIVOT’s improvement comes from the objective verification step? Does the per-step decrease in the frozen objective actually lead to better final reconstruction quality?

  2. Different tasks use different hyperparameters. Does the method rely too heavily on task-specific hyperparameter tuning?

Limitations

yes

Final justification

The rebuttal directly addresses my questions and clearly defines the scope of the method. The new verifier ablation shows that objective verification serves as a useful safeguard when proposal updates are overly aggressive, but it is inactive and provides no reconstruction gain under the nominal configuration. The parameter transfer study suggests that some schedule parameters can be shared, while the proposal step size and smoothing magnitude still require task level calibration. The additional trajectory analysis is informative but relies on strong assumptions and does not establish general improvement of the full sampling process. Moreover, the novelty remains primarily in the combination and interaction of existing components. I therefore maintain my score of 3. However, I recognize the practical value, coherent design, and broad experimental evaluation of the work, and I would not oppose acceptance.

Formatting concerns

No

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for highlighting novelty versus established primitives and the theory’s local scope. We agree that PIVOT’s novelty is interface-level, not primitive-level, and that it is task-calibrated, not parameter-free.

W1. The contribution is an interface, not a new primitive.

Quadratic tethering, heavy-ball momentum, smoothing, dyadic scale search, and fresh re-noising have precedents; novelty lies in their objective-asymmetric coupling. At each corrected step, a predictive-inertial branch generates proposals using Φˉk\bar{\Phi}_ k when smoothing is active. Eqs. (5)–(6) jointly select proposal index jj and dyadic scale bb under the original unsmoothed, denoiser-tethered Φk\Phi_k, with μk\mu_k as fallback. Neither inertial dynamics nor a smoothed-surrogate update is committed directly; only verified zk+z_k^+ is reinserted by fresh noising at σk+1\sigma_{k+1}.

Versus momentum/history guidance [15,49], dynamics remain in proposal generation and are screened before commitment. Versus one-direction step-length search [2,29], PIVOT verifies a finite family over proposal time and scale even when proposal and acceptance objectives differ. Versus DAPS-style methods [50], which separate data consistency from denoising/noise evolution across broader blocks, PIVOT does so within each corrected step.

Under the stated local assumptions, Theorem 1 contracts the original unsmoothed frozen objective up to explicit surrogate discrepancy; Proposition 2 gives dominance over the tested dyadic family, conditional constant-factor recovery of optimal line decrease, displacement control, and fresh-noise reinsertion bounds. We will revise the introduction and related work to state this narrower interface contribution without implying component novelty.

W2. The retained theory is strictly local.

The per-step result does not establish monotonic full-trajectory improvement, global optimality, or calibrated posterior sampling. Sufficient conditions follow.

Theorem (conditional full-trajectory error recursion). Let xk=G(μk)x_k=G(\mu_k), x~k=G(zk+)\tilde{x}_k=G(z_k^+), ek=∥xk−x⋆∥2e_k=\|x_k-x^\star\|_2, rk=∥A(xk)−y∥2r_k=\|A(x_k)-y\|_2, Δk=zk+−μk\Delta_k=z_k^+-\mu_k, and y=A(x⋆)+ξy=A(x^\star)+\xi, ∥ξ∥2≤δ\|\xi\|_2\le\delta. For rk>0r_k>0, define

qk:=rk2−βkσy2∥Δk∥22+2σy2ηkrk≥0.q_k:=\frac{\sqrt{r_k^2-\beta_k\sigma_y^2\|\Delta_k\|_2^2+2\sigma_y^2\eta_k}}{r_k}\ge0.

Here βk>0\beta_k>0, σy\sigma_y, and ηk≥0\eta_k\ge0 denote tether weight, likelihood scale, and selection slack; verification makes the radicand nonnegative. Assume, for x∈{xk,x~k}x\in\{x_k,\tilde{x}_k\},

mk∥x−x⋆∥2≤∥A(x)−A(x⋆)∥2≤Mk∥x−x⋆∥2,mk>0,m_k\|x-x^\star\|_2\le\|A(x)-A(x^\star)\|_2\le M_k\|x-x^\star\|_2, \qquad m_k>0,

and ∥xk+1−x⋆∥2≤ck+1∥x~k−x⋆∥2+bk+1\|x_{k+1}-x^\star\|_ 2\le c_{k+1}\|\tilde{x}_ k-x^\star\|_ 2+b_{k+1}. Then

ek+1≤ρkek+ak,ρk=ck+1qkMkmk,ak=ck+1(qk+1)δmk+bk+1,e_{k+1}\le\rho_ke_k+a_k, \qquad \rho_k=\frac{c_{k+1}q_kM_k}{m_k}, \qquad a_k=\frac{c_{k+1}(q_k+1)\delta}{m_k}+b_{k+1},

and, with empty products equal to one,

eT≤(∏k<Tρk)e0+∑j<T(∏r=j+1T−1ρr)aj.e_T\le\left(\prod_{k<T}\rho_k\right)e_0+ \sum_{j<T}\left(\prod_{r=j+1}^{T-1}\rho_r\right)a_j.

Clean-prediction PSNR is monotone if ρk≤1\rho_k\le1 and ak≤(1−ρk)eka_k\le(1-\rho_k)e_k. Under δ=ηk=bk=0\delta=\eta_k=b_k=0, global measurement stability on the stated domain, and ρk≤ρ<1\rho_k\le\rho<1, eT≤ρTe0e_T\le\rho^Te_0; thus clean predictions converge geometrically to x⋆x^\star, the unique data-consistent minimizer there. The zero-residual case is direct. These conditions are stronger than the original local assumptions and do not imply calibrated posterior sampling; the revision will include the full proof.

W3, Q2. Dependence on task-specific hyperparameters.

Shared schedule shares (ρα,γ,spp)(\rho_\alpha,\gamma,s_{\mathrm{pp}}) separately within pixel and latent spaces. Shared schedule+smoothing also shares (cpp,τmax⁡)(c_{\mathrm{pp}},\tau_{\max}), leaving only (K,J,α0)(K,J,\alpha_0) task-specific. Values use a fixed Table-3 median-mode rule, not these outcomes.

Table 1. Preliminary paired FFHQ-10 transfer. Entries are PSNR changes in dB relative to the submitted settings.

Task Shared schedule Shared schedule+smoothing
Random inpainting −0.130-0.130 −0.130-0.130
HDR −0.304-0.304 −0.849-0.849
Phase retrieval −0.366-0.366 −0.366-0.366
Latent 4×4\times SR −0.128-0.128 −0.128-0.128
Mean −0.232-0.232 −0.368-0.368
Worst task −0.366-0.366 −0.849-0.849

The concern is partly correct: PIVOT is training-free, but not parameter-insensitive at its best operating point. Still, Table 3’s eight task-dependent entries are not equally sensitive tuning dimensions: (K,J)(K,J) sets the quality–runtime budget; (ρα,γ,spp)(\rho_\alpha,\gamma,s_{\mathrm{pp}}) sets proposal schedule and smoothing frequency; the main task-sensitive quantities are proposal scale α0\alpha_0 and smoothing magnitude (cpp,τmax⁡)(c_{\mathrm{pp}},\tau_{\max}).

We tested transfer on paired FFHQ-10 random inpainting, HDR, phase retrieval, and latent 4×4\times SR. Shared values used a deterministic pixel/latent median-mode rule on submitted Table 3 settings, not outcomes. With identical images, measurements, measurement noise, and sampling seeds, sharing (ρα,γ,spp)(\rho_\alpha,\gamma,s_{\mathrm{pp}}) within each model space changed PSNR by −0.232-0.232 dB on average (worst: −0.366-0.366 dB), SSIM by −0.016-0.016, LPIPS by +0.007+0.007, and mean runtime by 0.877×0.877\times. Thus these schedule parameters transferred with limited degradation in this preliminary study.

Complete sharing is unsupported. Also sharing (cpp,τmax⁡)(c_{\mathrm{pp}},\tau_{\max}), leaving only (K,J,α0)(K,J,\alpha_0) task-specific, increased mean PSNR loss to −0.368-0.368 dB and worst-task loss to −0.849-0.849 dB on HDR. A local multiplicative sweep also showed α0\alpha_0 is task-dependent: the same change can improve one operator and degrade another. We therefore do not claim a universal configuration.

Our revised interpretation is that apparent tuning dimensionality overstates dependence: (K,J)(K,J) chooses the compute operating point; several schedule parameters can be shared with limited average degradation; α0\alpha_0 and smoothing magnitude require task-level calibration for best performance. Each task/representation preset was selected once on a fixed development subset, frozen across images, and reused unchanged on FFHQ and ImageNet; there was no per-image or FFHQ-vs.-ImageNet retuning. We will report the development/evaluation split, shared values and construction rule, and task-level selection protocol, and list task-level calibration as a limitation. These paired 10-image results are preliminary and do not replace the full 100-image evaluation.

Q1. How much improvement comes from objective verification.

The frozen-objective guarantee is local, not final-quality. Because the anchor, reverse state, noise level, and Φk\Phi_k change across steps, Φk(zk+)≤Φk(μk)\Phi_k(z_k^+)\le\Phi_k(\mu_k) does not imply that every accepted correction improves final PSNR, SSIM, or LPIPS. We therefore evaluated its marginal effect in the complete pipeline.

Table 6 and the new experiment cover different regimes. Table 6 adds verification to a short unverified first-order loop before inertia/smoothing; its baseline-to-+A transition shows that verification can improve that regime, but is not the verifier’s marginal contribution in jointly calibrated PIVOT.

We isolated verification in complete FFHQ latent 4×4\times SR. Both arms use the same 100 images, measurements, diffusion schedules, proposal parameters, initial states, and keyed random streams. The unverified arm commits the raw final proposal. Positive differences favor verification; oriented Δ\DeltaLPIPS is unverified minus verified, so positive means lower LPIPS. CIs are unadjusted 95% image-paired percentile-bootstrap intervals over 10,000 resamples. An actionable image has at least one verification-changed committed state; “commits” counts these over the trajectory.

Table 2. Verifier ablation on FFHQ latent 4×4\times SR. Positive metric differences favor verification; oriented Δ\DeltaLPIPS reports unverified minus verified, so positive values indicate lower LPIPS.

Contrast nn Actionable images (commits) Δ\DeltaPSNR$\uparrow$ (95% CI) Δ\DeltaSSIM$\uparrow$ (95% CI) Oriented Δ\DeltaLPIPS$\uparrow$ (95% CI)
Nominal 1×1\times: verified vs. unverified 100 0/100 (0) 0 0 0
Aggressive 4×4\times: verified vs. unverified 100 99/100 (960) +0.1241  [−0.0304,+0.2802]+0.1241\;[-0.0304,+0.2802] +0.0060  [+0.0017,+0.0098]+0.0060\;[+0.0017,+0.0098] +0.0043  [+0.0007,+0.0079]+0.0043\;[+0.0007,+0.0079]

At reported α0=10−4\alpha_0=10^{-4}, verification makes no material intervention. Thus it is not the source of nominal gain in this calibrated latent-SR setting, and Table 6’s larger gain should not be attributed to complete PIVOT.

We then increased only α0\alpha_0 to 4×10−44\times10^{-4}, intentionally making proposals aggressive. The stress factor was chosen by an objective-only overshoot criterion before examining reconstruction quality. Verification became active on 99/100 images and changed 960 commitments. Versus unverified, it improved mean SSIM by 0.0060 (95% CI [+0.0017,+0.0098][+0.0017,+0.0098]) and reduced mean LPIPS by 0.0043 (95% CI [+0.0007,+0.0079][+0.0007,+0.0079]). PSNR was +0.1241+0.1241 dB, but its CI [−0.0304,+0.2802][-0.0304,+0.2802] includes zero, so we do not claim established PSNR improvement.

Thus, a lower current frozen objective does not universally imply better final quality. At the nominal point, verification neither changes the trajectory nor adds quality; when proposal scale is deliberately misspecified and verification blocks aggressive commitments, its local decisions improve final SSIM and LPIPS on average, while PSNR remains inconclusive.

We will describe verification as a conditional acceptance safeguard against proposal overshoot and scale misspecification, not a universal or dominant source of nominal gains. The theory remains frozen per-step nonincrease; final-quality benefit is empirical and appears when verification changes the committed trajectory.

Reviewer 5Sk6OpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper addresses measurement-guidance instability for training-free diffusion priors in inverse problems. Direct step-by-step measurement corrections can disrupt diffusion trajectories under non-linear measurements, high noise, or latent space geometries. The authors propose PIVOT (Predictive-Inertial Verification with Objective Tethering), which decouples proposal generation from acceptance verification. PIVOT sets the denoiser prediction as a local clean anchor, applies predictive smoothing and heavy-ball momentum to generate candidate corrections, and utilizes a dyadic verification step via a tethered objective to filter or fallback to the anchor. Accepted proposals are re-noised to continue sampling. Local per-step contraction bounds are verified theoretically. Evaluated across FFHQ, ImageNet, and fastMRI, PIVOT offers a viable speed-quality trade-off and achieves top PSNR on fastMRI.

Strengths and weaknesses

Strengths:

  1. Addresses a critical issue, trajectory disruption caused by standard direct guidance, by separating proposal generation from objective-tethered verification.
  2. Integrates inertia-driven momentum, localized quadratic tethers, and dyadic verification into a well-engineered pipeline.
  3. Provides cohesive per-step theoretical boundaries (contraction and scale robustness) without overclaiming global posterior convergence.

Weaknesses:

  1. Performance is competitive but not uniformly superior; baselines like FAST-DIPS, SITCOM, or DAPS frequently match or outperform PIVOT in runtime, LPIPS, or specific task metrics.
  2. Core ablations are evaluated on only 10 FFHQ images across two tasks, offering insufficient empirical depth to firmly back the multi-component architecture.
  3. Proving local non-increase for a frozen per-step objective does not directly translate to a guaranteed global increase in standard metrics like PSNR or LPIPS.
  4. While PIVOT claims the highest PSNR on fastMRI, its structural SSIM scores fall behind DAPS and DDS, which is a significant drawback for clinical diagnostic integrity.
Questions

How were task-specific hyperparameters chosen? Were baselines given an equivalent tuning search budget?

Can you provide comprehensive side-by-side ablations of predictive smoothing across non-linear deblurring, phase retrieval, and MRI?

Can you present clear visualization of failure cases involving severe domain mismatch, non-differentiable operators, or adversarial latent space maps?

Limitations

yes

Final justification

Thank you for the authors’ response. I appreciate the clarifications but will maintain my original score.

Formatting concerns

N/A

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for the careful review. We agree that the original 10-image cumulative ablation was too small to support broad claims about individual components, that PIVOT is not uniformly best, and that local objective verification should not be interpreted as a global image-metric or clinical guarantee.

W1. Competitive rather than uniformly superior.

We agree. We will state that PIVOT provides a favorable speed–quality trade-off across the evaluated suite, while FAST-DIPS, SITCOM, and DAPS are stronger for several task–metric–runtime combinations, including some settings in super-resolution, deblurring, phase retrieval, perceptual quality, and MRI SSIM.

Table 1. Cumulative component ablation on 100 FFHQ images. The protocol and component order match the submitted Table 6: A denotes objective verification, B denotes inertial proposal dynamics, and C denotes predictive smoothing.

Task Setting PSNR$\uparrow$ SSIM$\uparrow$ LPIPS$\downarrow$ sec/img$\downarrow$
Pixel HDR Baseline 19.186 0.688 0.405 0.84
+A 21.315 0.769 0.306 1.06
+A + B 24.928 0.828 0.235 1.06
+A + B + C 26.331 0.842 0.216 1.63
Latent 4×4\times SR Baseline 25.855 0.738 0.388 21.90
+A 27.292 0.772 0.348 40.73
+A + B 29.304 0.830 0.279 42.25
+A + B + C 29.306 0.830 0.279 43.37

W2. Expanded component ablation (n=100n=100).

We agree that the original 10-image ablation was insufficient for a multi-component conclusion. We therefore repeated the exact cumulative Table 6 protocol on 100 FFHQ images for pixel HDR and latent 4×4\times SR. The main ordering is preserved: verification improves both tasks before inertia is introduced (+2.129/+1.437+2.129/+1.437 dB), and inertia provides the largest subsequent gain (+3.613/+2.012+3.613/+2.012 dB). Smoothing gives a further +1.403+1.403 dB on nonlinear HDR, while its previously small latent-SR effect becomes negligible. We will replace Table 6 with the 100-image result in the revision.

W3. Technical distinction and theoretical scope.

Frozen-objective nonincrease cannot unconditionally guarantee improved PSNR/LPIPS for an ill-posed operator; a direct certificate requires local observability. Let y=A(x⋆)+ξy=A(x^\star)+\xi, ∥ξ∥2≤δ\|\xi\|_ 2\le\delta, xμ=G(μ)x_\mu=G(\mu), x+=G(z+)x_+=G(z^+), rμ=∥A(xμ)−y∥2r_\mu=\|A(x_\mu)-y\|_ 2, r+=∥A(x+)−y∥2r_+=\|A(x_+)-y\|_ 2, and Δ=z+−μ\Delta=z^+-\mu. With tether weight β>0\beta>0, likelihood scale σy\sigma_y, and slack η≥0\eta\ge0, verification yields, provided that the radicand is nonnegative,

r+≤s+:=rμ2−βσy2∥Δ∥22+2σy2η.r_+\le s_+:=\sqrt{r_\mu^2-\beta\sigma_y^2\|\Delta\|_2^2+2\sigma_y^2\eta}.

Assume restricted measurement stability for x∈{xμ,x+}x\in\{x_\mu,x_+\}:

m∥x−x⋆∥2≤∥A(x)−A(x⋆)∥2≤M∥x−x⋆∥2,m>0.m\|x-x^\star\|_2\le\|A(x)-A(x^\star)\|_2\le M\|x-x^\star\|_2, \qquad m>0.

For nn image entries and peak range RR,

PSNR⁡(x+,x⋆)≥10log⁡10nR2m2(s++δ)2,\operatorname{PSNR}(x_+,x^\star)\ge10\log_{10}\frac{nR^2m^2}{(s_++\delta)^2},

and PSNR is nondecreasing relative to xμx_\mu if

s++δ≤(m/M)(rμ−δ)+,(a)+:=max⁡(a,0).s_++\delta\le(m/M)(r_\mu-\delta)_ +, \qquad (a)_+:=\max(a,0).

Thus, noiseless exact verification is PSNR-monotone for a scaled isometry (m=Mm=M). If, locally,

p‾∥x−x⋆∥2≤LPIPS⁡(x,x⋆)≤pˉ∥x−x⋆∥2,\underline{p}\|x-x^\star\|_2 \le\sqrt{\operatorname{LPIPS}(x,x^\star)} \le\bar{p}\|x-x^\star\|_2,

a sufficient LPIPS condition is

pˉ(s++δ)/m≤p‾(rμ−δ)+/M.\bar{p}(s_++\delta)/m\le\underline{p}(r_\mu-\delta)_+/M.

These are restricted sufficient conditions, not unconditional guarantees for operators with nullspaces; the formal statement and proof will be included in the revision.

W4. MRI SSIM and clinical interpretation.

We agree that the MRI result reflects a distortion–structure trade-off, not evidence of clinical superiority. DAPS has the best SSIM at both acceleration factors. PIVOT has a lower SSIM than DDS at 4×4\times (0.657 vs. 0.678) and a slightly higher SSIM at 8×8\times (0.596 vs. 0.593), while achieving the highest benchmark PSNR. We will restrict the claim to benchmark PSNR and state explicitly that neither PSNR nor SSIM establishes diagnostic integrity.

Q1. Hyperparameter selection and baseline tuning budget.

PIVOT is training-free, but not parameter-free. We did not perform an unrestricted joint search over all task-specific hyperparameters. For each task–representation pair (pixel or latent), we first fixed the representation-level settings—the diffusion/noise schedule, likelihood scale, verification budget and tolerance, and predictive-probe count—and then performed a sequential, runtime-aware search on a fixed development subset. Specifically, we first selected (K,J)(K,J) to set the quality–runtime budget, then tuned (α0,ρα,γ)(\alpha_0,\rho_\alpha,\gamma) for the proposal dynamics, and finally evaluated (cpp,τmax⁡,spp)(c_{\mathrm{pp}},\tau_{\max},s_{\mathrm{pp}}) for predictive smoothing. At each stage, we selected the candidate with the highest mean development-set PSNR, using runtime as the tie-breaker. The resulting task–representation preset was then frozen for all images and applied unchanged to both FFHQ and ImageNet, with no per-image or dataset-specific retuning.

No matched baseline search was used for the submitted tables. We used the official implementations and recommended/default task settings, and therefore do not claim equal historical or experimental tuning effort. To test whether this choice explains the HDR result, we conducted an additional matched configuration-count audit. PIVOT, DAPS, and FAST-DIPS each received the official configuration plus seven Sobol candidates whose ranges and seed were fixed before evaluation. The same 10 FFHQ development images were used for configuration selection, and the selected configuration for each method was evaluated once on the disjoint remaining 90 paired images. PIVOT obtained 28.073 dB at 5.48 s/image, compared with 27.113 dB at 24.23 s/image for DAPS and 25.924 dB at 6.25 s/image for FAST-DIPS. This audit matches the number of candidate configurations and development images, not GPU-hours or unknown historical development effort; because the cost of one configuration differs across methods, we do not present it as an equal-compute study. We will report the candidate ranges, Sobol seed, and per-method tuning compute, and will present this result strictly as a 10-development/90-evaluation HDR audit rather than a 100-image held-out result.

Q2. Side-by-side predictive-smoothing comparisons.

We switched smoothing on or off while holding the images, measurements, schedules, proposal budgets, verifier, and keyed random streams fixed. Deltas are computed as smoothing-on minus smoothing-off, so a lower Δ\DeltaLPIPS is better. The natural-image PSNR intervals are unadjusted, image-paired 95% percentile-bootstrap intervals based on 10,000 resamples.

Table 2. Predictive-smoothing ablation. Natural-image PSNR entries include unadjusted, image-paired 95% percentile-bootstrap confidence intervals.

Setting Δ\DeltaPSNR$\uparrow$ (95% CI) Δ\DeltaSSIM$\uparrow$ Δ\DeltaLPIPS$\downarrow$ Time$\times$
Nonlinear deblurring −0.0047  [−0.0166,0.0079]-0.0047\;[-0.0166,0.0079] −0.00004-0.00004 +0.00004+0.00004 1.89
Phase retrieval +0.0006  [−0.0011,0.0023]+0.0006\;[-0.0011,0.0023] +0.00018+0.00018 +0.00006+0.00006 1.15
Accelerated MRI (4×,8×4\times,8\times) 0 0 — 1.13

The requested matched comparisons show that predictive smoothing does not provide a measurable endpoint-quality benefit for nonlinear deblurring, phase retrieval, or the auxiliary MRI diagnostic: the natural-image PSNR confidence intervals include zero, the SSIM/LPIPS changes are negligible, and runtime increases. However, HDR is a clear exception. In the submitted n=10n=10 cumulative ablation, adding smoothing improved PSNR from 24.466 to 25.408 dB (+0.942+0.942 dB), and the expanded n=100n=100 rerun preserves the same direction, improving PSNR from 24.928 to 26.331 dB (+1.403+1.403 dB), together with improved SSIM and LPIPS.

Accordingly, the evidence supports predictive smoothing as a task-dependent component with a substantial benefit on HDR, but not as a generally beneficial default. We will revise the paper to make this narrower claim. Proposition 1 separately shows that smoothing is analytically inactive for linear FF under a Gaussian measurement loss.

Q3. Failure cases.

Three fixed 10-image tests paired measurements/noise with controls; indices and strengths were pre-fixed.

Domain mismatch causes moderate degradation that verification cannot detect. Hard JPEG-Q10 without a straight-through estimator or surrogate yields zero gradient/correction RMS and a bitwise denoiser-only result, so native PIVOT cannot use it.

For fixed orthogonal QQ, the anchor-preserving adversarial map is

Gk,s(z)=Dec⁡ ⁣(μk+Ts(z−μk)),Ts=Qdiag⁡(s,s−1,1,1)Q⊤,cond⁡(Ts)=s2.G_{k,s}(z)=\operatorname{Dec}\!\left(\mu_k+T_s(z-\mu_k)\right), \qquad T_s=Q\operatorname{diag}(s,s^{-1},1,1)Q^\top, \qquad \operatorname{cond}(T_s)=s^2.

At s=8s=8 (condition number 64), PSNR falls from 29.506 to 17.004 dB despite shrinkage at 58.8% of active steps. No non-finite outputs occur; the local safeguard cannot repair pathological decoder geometry.

Given the format and space constraints of the OpenReview rebuttal, we provide the quantitative stress-test results here; in the revised manuscript, we will include visualizations of the three failure modes, together with matched controls and error maps.

Table 3. Fixed 10-image failure stress tests. Rows use different tasks/operators, so absolute values should not be compared across rows.

Failure case PSNR$\uparrow$ SSIM$\uparrow$ LPIPS$\downarrow$
FFHQ prior →\rightarrow ImageNet 21.329 0.819 0.279
Hard JPEG, quality 10 10.850 0.392 0.697
Ill-conditioned latent map, s=8s=8 17.004 0.448 0.629

Matched-control (Δ\DeltaPSNR, Δ\DeltaSSIM, Δ\DeltaLPIPS): domain mismatch (−0.635,−0.013,+0.023-0.635,-0.013,+0.023); hard JPEG versus denoiser-only (0,0,0)(0,0,0); s=8s=8 versus native latent map (−12.503,−0.382,+0.343-12.503,-0.382,+0.343).

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?