potentialpaper

Efficient Factorized Volume Synthesis with Lifted Inter-Slice Feature Trajectories

Xinhe Zhang, Yuyang Zhang, Pengfei Jin, Arnau Marin-Llobet, Na Li, Quanzheng Li

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. LiFT factorizes 3D medical-image synthesis into a 2D slice generator plus a small depth-indexed trajectory module, supervised distributionally by tri-planar drifting for unconditional MR or directly by a ground truth for paired translation.

Abstract. High-resolution 3D medical image generation remains challenging because fully volumetric models are computationally expensive, while efficient 2D slice generators often fail to preserve anatomical consistency across the third dimension. We propose LiFT, a framework for Lifted inter-slice Feature Trajectories that factorizes 3D volume synthesis into per-slice image generation and inter-slice trajectory learning. Rather than using a fully volumetric synthesis backbone, LiFT treats a volume as an ordered trajectory in feature space, capturing how anatomical structures appear, transform, and disappear across depth. We demonstrate the LiFT framework in both unconditional and conditional settings. In unconditional generation, a tri-planar drifting loss matches feature distributions between generated and real volumes across three orthogonal planes; in paired translation, a bidirectional zz-context mixer trained with paired target supervision supplies through-plane coherence while preserving per-slice fidelity. We evaluate LiFT on BraTS 2023 for unconditional and missing-modality MR synthesis, and on SynthRAD2023 for MR-to-CT translation. LiFT achieves competitive image quality while retaining the efficiency of predominantly 2D synthesis, operating up to 390×390\times faster than a volumetric diffusion baseline and consistently improving through-plane coherence through explicit inter-slice modeling. These results establish lightweight inter-slice trajectory learning as an efficient approach to high-resolution 3D medical synthesis.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
5 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]—[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:49 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

This paper proposes a 3D medical image synthesis method by integrating 2D slice generators. While the reviewers agree that the task is well motivated and the proposed solution is generally sound, they also raised concerns regarding the missing comparisons against SOTA methods, inadequate analysis, insufficient technical innovations, insufficient clinical evidence, and missing technical details and confusing presentation. The authors are encouraged to carefully review the reviewers' comments and address all concerns in the rebuttal.


Final meta-review: the rebuttal provided additional results, including new baselines, statistical analysis, coherence and lesion-level evaluations, and the requested ablations, directly addressing the reviewers' concerns. Nevertheless, several limitations still remain: there newly provided results weren't sufficiently documented, the revised model differs somewhat from the submitted one, and the anatomical/clinical evaluation is still fairly coarse. As a result of the rebuttal, two reviewers increased their scores after the rebuttal, resulting in final ratings of 4/5/3.

Overall, the area chairs agree with the reviewers' assessments and find the merits outweigh the current limitations. The factorization is simple, the efficiency gains are large, and what's left is mostly documentation and scoping rather than the validity of the results. Hence, the area chairs recommend to accept the submission. However, the authors will have to incorporate substantial changes in the revision, including the new benchmark results, ablations, and revised figures, documenting the new protocols and flag which configuration was used where, and carefully scoping their claims to the evaluated brain-imaging tasks rather than broad clinical validity.

Final justification

Overall, the area chairs agree with the reviewers' assessments and find the merits outweigh the current limitations. The factorization is simple, the efficiency gains are large, and what's left is mostly documentation and scoping rather than the validity of the results. Hence, the area chairs recommend to accept the submission. However, the authors will have to incorporate substantial changes in the revision, including the new benchmark results, ablations, and revised figures, documenting the new protocols and flag which configuration was used where, and carefully scoping their claims to the evaluated brain-imaging tasks rather than broad clinical validity.

Area Chair 844g · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

This paper proposes a 3D medical image synthesis method by integrating 2D slice generators. While the reviewers agree that the task is well motivated and the proposed solution is generally sound, they also raised concerns regarding the missing comparisons against SOTA methods, inadequate analysis, insufficient technical innovations, insufficient clinical evidence, and missing technical details and confusing presentation. The authors are encouraged to carefully review the reviewers' comments and address all concerns in the rebuttal.


Final meta-review: the rebuttal provided additional results, including new baselines, statistical analysis, coherence and lesion-level evaluations, and the requested ablations, directly addressing the reviewers' concerns. Nevertheless, several limitations still remain: there newly provided results weren't sufficiently documented, the revised model differs somewhat from the submitted one, and the anatomical/clinical evaluation is still fairly coarse. As a result of the rebuttal, two reviewers increased their scores after the rebuttal, resulting in final ratings of 4/5/3.

Overall, the area chairs agree with the reviewers' assessments and find the merits outweigh the current limitations. The factorization is simple, the efficiency gains are large, and what's left is mostly documentation and scoping rather than the validity of the results. Hence, the area chairs recommend to accept the submission. However, the authors will have to incorporate substantial changes in the revision, including the new benchmark results, ablations, and revised figures, documenting the new protocols and flag which configuration was used where, and carefully scoping their claims to the evaluated brain-imaging tasks rather than broad clinical validity.

Final justification

Overall, the area chairs agree with the reviewers' assessments and find the merits outweigh the current limitations. The factorization is simple, the efficiency gains are large, and what's left is mostly documentation and scoping rather than the validity of the results. Hence, the area chairs recommend to accept the submission. However, the authors will have to incorporate substantial changes in the revision, including the new benchmark results, ablations, and revised figures, documenting the new protocols and flag which configuration was used where, and carefully scoping their claims to the evaluated brain-imaging tasks rather than broad clinical validity.

Reviewer PQnzOpenReview ↗
Rating
3/6
Confidence
4/5
Quality
2/4
Clarity
2/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper addresses 3D medical image synthesis, motivated by the trade-off that fully volumetric generators are expensive while purely slice-wise 2D generators struggle to maintain consistency along the through-plane axis.

The central idea is a factorization: a predominantly 2D synthesizer handles high-resolution in-plane slice formation, while a lightweight, depth-indexed "trajectory" module handles only through-plane organization.

The method is evaluated across three settings—unconditional MR generation (BraTS 2023), missing-modality MR synthesis (BraTS 2023, vs. cWDM), and MR-to-CT synthesis (SynthRAD2023)—reporting per-slice quality, through-plane coherence, inference cost, a no-mapper ablation, and appendix analyses (bootstrap CIs, paired Wilcoxon tests, a memorization probe, and depth-trajectory PCA).

I read the main contributions as: (1) the 2D-synthesizer-plus-lightweight-trajectory-module factorization, with the claim that through-plane organization can be added cheaply; (2) LiFT-U, using a frozen 2D generator and a depth mapper trained by tri-planar drift; (3) LiFT-C, using a BiGRU z-context mixer with memory-efficient native-resolution inference; and (4) an evaluation showing the principle transfers across both unconditional and paired regimes at lower inference cost than volumetric or iterative alternatives.

Strengths and weaknesses

Strengths : The experiment is basically complete. I think the idea is somewhat novel. The evaluation indicators are also basically appropriate.

Weaknesses : 1. The comparisons neither establish SOTA nor isolate the contribution against the right baselines. My main concern is that the experimental design does not cleanly support the central claim. Two problems compound. First, on the paired tasks the results do not actually demonstrate state-of-the-art performance, and the paper's framing slightly obscures this. On missing-MR (Tables 2–3), LiFT-C trails cWDM on the averages for both PSNR (28.31 vs. 28.42 dB) and SSIM (0.9518 vs. 0.9525), and the authors' own paired Wilcoxon tests find no significant difference at any contrast (p≥0.37). Second, LiFT is benchmarked only against fully-volumetric and naive slice-wise baselines.

2. Figures 1 and 2 are difficult to follow and, in places, internally inconsistent. I am concerned they were AI-generated without careful post-editing. The clearest symptom is in Figure 2, whose legend does not map onto the formulation it is supposed to illustrate. The drift loss in Eq. (4) involves exactly three objects: the generated feature gg g, the bank of real features {rk}, and the kernel-weighted local target μ. The legend, however, lists more marker types than this, and they cannot be matched back to the equation. Most confusingly, it contains two separate entries that both read "local mean"—"Drift target (local mean)" (the × glyph) and "Drift target in real distribution (local mean)" (the ⋆ glyph)—using different markers but identical descriptions. A reader cannot tell whether these denote the same quantity (in which case why two glyphs?) or two different quantities (in which case the labels fail to distinguish them).

3. The architecture of the depth mapper MϕM_\phi is never specified. The paper describes it only as a "lightweight network" with a 1.4551.455M parameter count (Appendix E.1), but gives no layer structure—is it an MLP, and of what depth?—and never states the dimensions of zz, γ(d)\gamma(d), or cdc_d (the symbol dcd_c is introduced in Eq. (1). For a paper whose central contribution is precisely "a lightweight depth-indexed trajectory module," leaving both the module's architecture and its interface to the generator undefined directly undermines reproducibility.

4. The paper lacks experimental setups and visualizations specifically targeting the inter-slice inconsistency problem. Given that through-plane coherence is the stated core contribution, the evaluation should be built around it directly—dedicated experiments and qualitative reformats that isolate and display slice-to-slice consistency—rather than relying on aggregate quality scores and figures that do not clearly show it.

5. The MR-to-CT no-mapper ablation conflates two mechanisms and so cannot attribute the improvement. Per Appendix E.3, "no mapper" is Stage 1 alone—a plain per-slice 2D U-Net with no BiGRU and hence no depth encoding—while the full model adds, simultaneously, both the BiGRU sequence model (which actually reads neighboring slices) and the Fourier depth signal γ(d). This matters for what the contribution is: if adding a plain normalized scalar depth input to the Stage-1 U-Net (no BiGRU) already recovered most of the benefit, the BiGRU-plus-Fourier design would not be shown to be necessary. I would suggest an intermediate ablation—no mapper → Stage-1 + depth encoding only, no BiGRU → full—to separate the two. Relatedly, the Fourier encoding itself is left unspecified (normalization of ddd, number/scale of frequencies), which is a reproducibility gap; for LiFT-U, where the trajectory module is not removable, this is purely a specification issue rather than an attribution one.

Questions

Please refer to the weaknesses.

Limitations

Overall, I find the motivation of this paper appealing: the inversion of the usual question—asking how little explicit 3D processing is needed once a strong 2D model is in place, rather than how to make a 3D generator cheaper—is a genuinely interesting starting point. My main suggestion is that the writing, the experimental design, and the figures do not yet cohere around this motivation as well as they should, and this is where the paper most needs improvement. Concretely: the evaluation should be built more directly around through-plane coherence (the stated core idea), including a direct coherence metric for LiFT-U and at least one comparison against a competing 2D-lifting method rather than only volumetric and naive slice-wise extremes; the exposition should fully specify the components that carry the contribution (MϕM_\phi Mϕ​, the conditioning interface, the context merge) rather than the peripheral details; and the figures need to be redrawn so they accurately and clearly convey the mechanism. With the motivation tightened into the design, evaluation, and presentation in this way, this could become a considerably stronger submission.

Final justification

After reading the rebuttal and discussion, I raise my rating from 2 to 3. The authors clarified the architecture, added the requested depth-only ablation, provided stronger statistical analysis of through-plane coherence, and expanded comparisons with recent baselines, which make the quality–efficiency claim more convincing.

Formatting concerns

N/A

5 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for the detailed, point-by-point review. We appreciate the specific concerns about baseline positioning, presentation, reproducibility, direct coherence evidence, and the MR-to-CT ablation. We address each below and report two new analyses: a direct coherence evaluation and the requested depth-only control.

1. Baselines, SOTA framing, and comparison with 2D-lifting methods. Our intended claim is not that LiFT has the best image-quality metric in every task. The main result is the quality–efficiency trade-off. On missing-MR, LiFT-C is within approximately 0.12 dB PSNR and 0.0007 SSIM of cWDM, while reducing inference time from 156.4 s to 1.16 s per volume (~135×). The nonsignificant paired Wilcoxon result does not establish equivalence or non-inferiority. We are re-evaluating the comparison with a formal equivalence/non-inferiority test and do not interpret the current p-values as evidence of equivalence.

We also completed a matched MAISI-v2 experiment on BraTS T1n at 128³ using the same MedicalNet-FID protocol:

Model FID (x10^3) ↓ Time / volume ↓
LiFT-U 0.066 0.039 s
MAISI-v2 0.294 0.506 s

Both timings were measured on an NVIDIA RTX 5090. Matched 3D MedDiffusion and Fast-cWDM evaluations are in progress, and we will share verified results as soon as they are available.

Table 1 includes the 2.5D-LDM result reported by WDM, which is a Make-A-Volume-style adaptation under the same evaluation protocol. However, this is a quoted result rather than our own matched reproduction, so it only partially addresses the requested baseline comparison. We will clarify this limitation and avoid presenting it as an independently rerun comparison.

2. Figures and presentation. We apologize that the current figures mix the shared conceptual idea with task-specific implementations, making the relationship between LiFT-U and LiFT-C harder to follow. We are revising the presentation by separating the conceptual overview from the two implementation diagrams, simplifying the notation, and making the captions self-contained.

The two Figure 2 legend entries labeled “local mean” are an editing error, not two different quantities. Both refer to the same kernel-weighted local target μ in Eq. (4). The revised figure will use a single marker for μ and show only the three quantities used by the loss: the generated feature g, the real feature bank {r_k}, and the local target μ. We will also label Figure 1 explicitly as a conceptual overview rather than a literal architecture diagram. We appreciate your careful attention to these presentation errors.

3. Depth mapper, conditioning interface, and reproducibility. We agree that these details are necessary for reproducibility and should have been stated explicitly. For LiFT-U, z∈R^{256} is combined with a Fourier encoding of depth and mapped to c_d∈R^{512} by a four-layer SiLU MLP followed by a lightweight residual depth refiner. The mapper has ≈1.455M trainable parameters, and each c_d conditions the frozen 2D generator through adaptive GroupNorm at every residual block. We will add the exact layer widths, Fourier-feature setup, kernel sizes, and initialization details in the revision. For LiFT-C, recurrence is applied only at the bottleneck and merged through a zero-initialized residual 1×1 convolution. The missing-MR model uses a two-layer bidirectional GRU over pooled 512-D slice descriptors, while the MR-to-CT model uses a single-layer bidirectional GRU over a 256-channel 16×16 bottleneck feature map. In item 5, the two BiGRU cells use the same MR-to-CT architecture and differ only in whether the depth term is included.

4. Direct evaluation of through-plane coherence. We appreciate this request and added direct through-plane measurements rather than relying mainly on aggregate image-quality metrics.

For LiFT-C, we evaluated the full model and the no-mapper control on the same 219-subject missing-MR validation set:

Coherence metric ↓ No mapper LiFT-C
Axial-bias SSIM gap 0.00270 0.00234
Normalized adjacent-slice error 0.6127 0.6015
Absolute adjacent-slice error 0.00399 0.00393
T2f normalized adjacent-slice error 0.690 0.661

The full per-contrast results improve all 12 cells (four contrasts × three metrics); the table reports the cross-contrast averages and the largest contrast-specific change.

For LiFT-U, paired derivative error is not defined because generated samples have no paired targets. We therefore added a real-calibrated roughness measure, A=Rz/Rxy, where Rz is adjacent-slice roughness and Rxy is in-plane roughness:

Group A = Rz/Rxy Raw Rz
Real BraTS 0.943 ± 0.118 0.0588
LiFT-U 0.881 ± 0.036 0.0607
Random slice permutation 2.627 ± 0.275 0.1804

This control shows that LiFT-U is far more orderly than a random slice permutation and that its through-plane roughness is on a similar scale to real BraTS volumes. It does not establish anatomical equivalence.

We are also revising the qualitative presentation so that coronal and sagittal reformats, rather than only axial slices, are used to make through-plane behavior easier to inspect.

5. MR-to-CT depth-only ablation. The submitted no-mapper ablation removed both recurrent context and depth encoding, so it could not isolate which component produced the gain. We therefore ran the intermediate control requested in the review.

The new control results are:

MR-to-CT setting Full-volume MAE ↓
No BiGRU, no depth 58.564 HU
No BiGRU, + Fourier depth 58.569 HU
BiGRU, no depth 57.404 HU
BiGRU, + Fourier depth 57.475 HU

Depth conditioning gives no improvement—it is essentially unchanged with or without the BiGRU—whereas recurrent context improves MAE by approximately 1.1 HU. This indicates that the gain is associated with inter-slice context rather than absolute slice position. We appreciate this suggestion, as the requested control helped us identify and isolate this important finding.

The individual ingredients—2D generators, GRUs, and Fourier features—are established. The contribution is the specific separation of responsibilities: the 2D model retains the high-capacity spatial synthesis path, while the added module is restricted to through-plane interaction. The new ablation and direct coherence measurements now test that separation much more directly than the original submission did.

We appreciate the specificity of these comments; the added controls, coherence analysis, and clearer technical description make the central claim substantially easier to assess.

Reviewer PQnz · CommentOpenReview ↗

Thank you for the detailed response. The additional coherence evaluation, architectural clarification, and depth-only ablation address several of my concerns. However, some important issues remain. The comparison with competitive 2D-lifting methods is still incomplete, and the new coherence results would benefit from stronger statistical analysis and more meaningful baselines. The exact implementation details and revised figures should also be included in the paper.

A major concern is still the lack of care in the current figures. The inconsistent legends and unclear correspondence between the diagrams and equations suggest that the possibly AI-assisted figures were not carefully checked or post-edited. Since the figures describe the central method, this significantly affects the clarity and reliability of the presentation.

Overall, the rebuttal provides useful new evidence, so I am willing to raise my score to 3. The paper still requires further refinement before it can be accepted.

Authors · CommentOpenReview ↗

Response 1/3

Thank you for raising your score and for identifying precisely what remains. Below, we present the analyses completed since our last response.

Figures and manuscript. We sincerely appreciate the reviewer identifying these presentation issues. We have revised both figures rather than correcting them element by element: a consistent visual language across both figures, every symbol checked against the equations, and text rendered as text rather than as an image. The discussion period does not permit uploading a revised PDF, so we describe the changes here. In the revision, Figure 2 no longer carries the legend strip that produced the duplicated "local mean" entries; the panel labels the projection operators explicitly as π_xy (axial), π_yz (sagittal) and π_xz (coronal), names the generated feature banks, and every remaining marker corresponds to one of the three quantities in Eq. (4) — the generated feature g, the real feature bank {r_k}, and the kernel-weighted local target μ. Figure 1 is labelled a conceptual overview and split into two implementation diagrams, one for LiFT-U and one for LiFT-C, so the shared principle and the task-specific realizations are no longer combined in a single panel. The related-work and motivation sections state the factorization question directly, and the mapper architecture, depth encoding, conditioning interface and context-merge layer are specified in the method section and appendix. On the qualitative side, Appendix Figure 4 already shows the missing-MR case in axial, coronal and sagittal reformats, with the no-mapper ablation alongside the full model and per-method error maps over the same volume; the revision promotes that comparison into the main text and frames it explicitly as through-plane evidence rather than general qualitative results. These changes are incorporated in our working revision and will appear in the revised manuscript.

Paired upper confidence bounds against cWDM. Matching LiFT-C and cWDM subject by subject across all 219 held-out cases, the one-sided 95% upper confidence bound on cWDM's advantage is 0.10 dB for average PSNR and 0.0002 for average SSIM, and the observed average SSIM difference in fact favours LiFT-C. Per-subject correlations are 0.80–0.97, so the paired analysis removes much of the between-patient variation. We report confidence bounds rather than testing against a fixed margin because no standard non-inferiority margin exists for this task; a bound of 0.10 dB is a stronger statement than a non-significant test, since it limits how large the difference could be rather than only failing to detect one.

Matched recent baselines. These evaluations use the same held-out subjects with identical preprocessing and metric code, and for unconditional generation all models were trained on the same BraTS T1n split. The FID values differ from our preliminary response because every method was reevaluated against the same 219-subject real reference used for the real-versus-real calibration.

Model FID ×10³ Time/volume Parameters
Real held-out calibration 0.056 — —
LiFT-U 0.086 0.039 s 30.3 M
3D MedDiffusion 0.085 15.37 s 166.3 M
MAISI-v2 0.279 0.506 s 201.4 M

LiFT-U and 3D MedDiffusion reach essentially the same FID, against a real-versus-real calibration floor of 0.056. For missing-MR, on all 219 subjects and all four targets:

Model Avg. PSNR Avg. SSIM Time/volume Parameters Steps
LiFT-C 28.417 0.9528 1.159 s 41.3 M 1
cWDM 28.425 0.9525 156.4 s 81.5 M 1000
Fast-cWDM 28.233 0.9456 15.53 s 81.5 M 100

LiFT-C is within 0.008 dB of cWDM on average PSNR and slightly ahead on average SSIM at 135× the speed, and improves on Fast-cWDM by 0.184 dB and 0.0072 SSIM at 13.4× the speed with about half the parameters.

Reviewer Ps2vOpenReview ↗
Rating
5/6
Confidence
3/5
Quality
4/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

Summary:

The paper introduces LiFT, a novel approach for 3D image generation. The idea behind LiFT is to harness the capacity of strong 2D image generators, while modeling the third dimension as a trajectory in the latent space of the 2D generator. To this end, LiFT employs a 2D GAN and a 2D encoder-decoder, to produce unconditioned and conditioned (image-translated) 2D slices. Then, two models are introduced: LiFT-U, and LiFT-C. LiFT-U learns plausible depth-wise walks in the latent space of the frozen 2D GAN, while LiFT-C learns to maintain anatomical consistency across translated slices. The proposed approach is highly efficient, as it avoids the burden of dense 3D modeling, and is reasonably competitive across the evaluations. The key innovation of the paper is in integration of existing concepts into the novel learning paradigm, and in demonstrating the outstanding properties of such approach.

Strengths and weaknesses

Strengths:

(S1) The proposed approach is sound and logical. There is existing precedent for modeling 3D volumes as sequences of 2D generator latent codes, and in the broader sense to solve complex tasks in the latent space of encoders and generative models to limit the computational load, while still achieving highly expressive modeling. In this context, LiFT is a valuable case study of how a modern approach can harness this principle to a highly effective and efficient end.

(S2) The evaluations are extensive and sufficiently nuanced. Evaluations report modern and informative metrics for medical image synthesis. The empirical evidence is strongly in favor of the proposed approach, in particular in terms of efficiency.

Weaknesses:

(W1) While it is entirely valid to limit the scope of this work to the field of medical imaging, we are wondering whether the proposed technique can find broader applications for modeling arbitrary, heterogeneous volumes, such as in scientific imaging. Since medical volumes are highly standardized in terms of orientation, resolution and noise distribution, we are wondering whether the elegant design as presented in the paper would also generalize to non-medical applications. We believe it would strengthen the presentation of the underlying technique to evaluate and discuss such scenario.

(W2) Incremental novelty. The paper offers system-level innovation by integrating existing designs in a non-trivial way. This is only a minor issue for us, given the overall high quality of the submission.

Quality:

The presented solutions are technically sound, with good empirical support for the underlying hypotheses. The authors openly discuss limitations of their technique.

Clarity:

The paper is well-written, well-illustrated, informative, and easy to understand. The authors intend to publish the code for reproducibility.

Significance:

The proposed approach offers massive performance gains in terms of inference speed and memory footprints. We believe this has critical significance for the application case.

Originality:

The proposed combination of previously known individual components and designs is entirely novel, and is clearly differentiated from related work.

Final justification:

We believe that LiFT is a high-quality contribution (S1, S2) that showcases an effective method with breakthrough efficiency and high significance for the field of medical imaging, even if the novelty is primarily on the level of integration (W2). While further discussion (W1, Q1) can offer improved insight into the limits of the proposed technique, we believe LiFT to be a valuable and important contribution to the field.

Questions

Questions:

(Q1) The inherent feature of the design of LiFT is that adjacent slices must lay close in the latent/conditioning space. Does that introduce limitations in terms of modeling sharp changes between the slices? For example, could it be that small, sharp anomalies with high importance for the downstream task are not feasible to model?

Limitations

yes

Final justification

In addition to our initial remarks, the authors have engaged constructively with the reviewers feedback, and provided further evidence and adjustments to the paper presentation.

Formatting concerns

No major formatting concerns

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for the thoughtful and constructive questions. We appreciate the concern that whole-volume coherence may still hide failures on small abnormalities. Below, we clarify what the current design does and does not establish, describe the evaluation we are preparing, and discuss broader generalization.

Small or abrupt abnormalities. We agree that a model can look globally coherent while still smoothing a small lesion that appears or disappears over only a few slices. The current submission does not isolate that failure mode, so we are preparing a lesion-stratified evaluation. This analysis requires tumor masks for the evaluated subjects, which are not included in the current held-out missing-MR split. Predictions from both the full and no-mapper models already exist for this split, so the analysis would be evaluation-only if masks for these subjects can be obtained. Otherwise, we would need a new mask-bearing split and matched retraining to avoid train-on-evaluation leakage. We will share the result as soon as the matched evaluation is complete.

The architecture does not include an explicit smoothness penalty. In LiFT-C, the through-plane loss is |Δ_zŶ − Δ_zY|_1, which matches the predicted derivative to the target derivative rather than suppressing the derivative. An abrupt change in the target is therefore part of the signal the model is trained to preserve. The original slice-wise encoder features and skip connections also remain intact; the BiGRU adds context at the bottleneck but does not replace the local 2D pathway. LiFT-U likewise has no explicit trajectory-smoothness penalty. These design choices do not by themselves establish lesion preservation; the lesion-stratified experiment is needed before making that claim.

Generalization beyond medical imaging. LiFT does not use anatomy-specific operators. A basic requirement is that the data have a meaningful ordered axis and that a strong 2D generator or translator already exists. In principle, the same factorization could be applied to microscopy stacks, materials tomography, or other scientific volumes by letting the 2D model handle in-plane structure and the trajectory module handle variation along the ordered axis. However, our experiments only cover aligned brain volumes. Domains with irregular spacing, changing orientation, sparse sampling, or strongly anisotropic noise may require different positional encodings, preprocessing, or a more flexible trajectory module. We therefore see this as a promising extension, not as generalization already demonstrated by the current results.

We appreciate these questions because they identify important tests of where the current evidence is strong and where further validation is still needed.

Reviewer Ps2v · CommentOpenReview ↗

Thank you for these insights. New quantitative evidence and details provided to other reviewers further strengthens the paper from our point of view. We maintain our rating.

From our side, we also see improvement potential in figures 1 and 2, and we also believe these are AI-generated and need some additional work. The issue is primarily in the lack of a single visual vocabulary and of a clear flow/rhythm in the layout. One also gets an ambiguous feeling whether the image thumbnails represent real tensors. Internal indexing (a-b-c), (1-2-3) is never used in the caption, and text is poorly rasterized. We believe these figures should be carefully re-done, however this is not a ground for reducing the rating from our side.

Authors · CommentOpenReview ↗

Thank you for maintaining your rating, and for the specific figure critique. Below we report the lesion-stratified evaluation and describe the figure revisions.

Lesion-stratified evaluation. The held-out missing-MR subjects have no released lesion masks, so we built a separate leakage-free split: 200 mask-bearing subjects, stratified by whole-tumour-volume decile, were held out, and both the full model and a no-mapper control were retrained per contrast without them. Lesions follow the BraTS-2023 lesion-wise convention (26-connectivity components, ground-truth dilation, 2 mm³ threshold) on the whole-tumour region. Measurements are aggregated within each patient, so patients are the sampling unit; p-values are two-sided paired Wilcoxon and intervals are 95% percentile bootstrap.

Contrast Δ lesion PSNR (dB) 95% CI p Δ lesion SSIM Δz error reduction
t2f +0.469 [+0.268, +0.677] 2.7×10⁻⁵ +0.0166 3.6%
t1c +0.038 [−0.073, +0.150] 0.64 +0.0070 2.2%
t2w −0.084 [−0.194, +0.025] 0.16 +0.0048 3.7%
t1n +0.255 [+0.103, +0.410] 0.0016 +0.0061 2.8%

Lesion SSIM improves significantly on all four contrasts (all p < 10⁻⁵), as does lesion-region through-plane error — the adjacent-slice derivative error |Δ_z Ŷ − Δ_z Y| restricted to the lesion region (all p < 10⁻¹⁸). Lesion PSNR improves significantly for t2f and t1n, while the differences for t1c and t2w are statistically inconclusive. The structural measures most directly related to the concern raised therefore improve consistently, whereas the lesion-PSNR evidence is contrast dependent.

The sharpest transitions specifically. An average over the whole lesion can obscure the abrupt transitions most susceptible to smoothing. Within each patient, we ranked lesion-region through-plane transitions by the ground-truth magnitude |Δ_z Y| and retained the top 10% before comparing the models. Measurements are aggregated per patient, so patients remain the sampling unit.

Contrast Δz error reduction Relative 95% CI p Bonferroni
t2f +0.00196 2.6% [+0.00149, +0.00245] 2×10⁻¹⁶ 9×10⁻¹⁶
t1n +0.00030 0.5% [+0.00004, +0.00056] 0.003 0.011
t2w +0.00031 0.5% [+0.00006, +0.00054] 0.007 0.029
t1c −0.00004 −0.03% [−0.00026, +0.00016] 0.84 1.0

Three contrasts improve and remain significant after Bonferroni correction across the four tests. For t1c the estimated difference is near zero and statistically inconclusive, the interval bounding it between −0.17% and +0.10% of that contrast's baseline error.

Although neighbouring conditioning vectors are organised along depth, the output is not constrained to change smoothly. Slice-specific information reaches the decoder through the unchanged 2D encoder and skip connections, while the through-plane loss matches the prediction's slice-to-slice derivative to the ground-truth derivative rather than penalising large derivatives. Abrupt changes in the target therefore remain part of the training signal.

This controlled comparison directly tests whether the trajectory module smooths lesion transitions. It improves sharp-transition reconstruction on three contrasts, while the t1c estimate is near zero and tightly bounded. The comparison isolates the module's effect but does not by itself establish absolute lesion fidelity.

Figures 1 and 2. We sincerely appreciate the reviewer identifying these presentation issues. We have rebuilt both figures in our working revision, though the discussion period does not permit uploading the revised PDF. One shape and stroke grammar now distinguishes frozen from learned components and data flow from gradient flow, with a single palette across both figures. The layout runs left to right on a shared column grid, so the pipeline reads in one direction. Every thumbnail carries its tensor shape and is marked as either a real sample or a schematic. Panel indices are referenced explicitly in the captions or removed. Both figures are rebuilt as vector art, so text is rendered as text rather than as an image. Figure 1 is additionally labelled a conceptual overview and split into separate LiFT-U and LiFT-C diagrams, so the shared principle and the task-specific realisations no longer share one panel.

We thank the reviewer for these questions, which helped us evaluate the specific failure mode more directly.

Reviewer kg5BOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes LiFT, a framework for 3D medical image synthesis using a 2D slice generator or translator plus a lightweight inter-slice trajectory module. In the unconditional setting, LiFT-U freezes a 2D slice generator and trains a depth-conditioned mapper using a tri-planar drifting loss. In paired translation, LiFT-C augments a 2D U-Net-style translator with a bidirectional GRU over bottleneck descriptors and supervised reconstruction/through-plane losses. The method is evaluated on BraTS 2023 for unconditional T1n MRI and missing-modality MRI synthesis, and on SynthRAD2023 brain MR-to-CT translation. The main reported result is that the approach retains slice-wise quality while improving through-plane coherence and reducing inference cost compared with volumetric diffusion-style models.

Strengths and weaknesses

Strengths
The paper presents a relevant problem and the motivation is clear (3D medical image generation), while presenting a simple and practical solution: keep high-resolution 2D synthesis where performance is already strong, and add only enough sequence/trajectory modelling to organize slices into a plausible volume. Figure 1 and the method section make this decomposition easy to understand. The LiFT-U/LiFT-C split is also sound since unconditional generation and paired translation require different supervision.

The experiments cover three clinically relevant settings rather than a single narrow benchmark: unconditional brain MRI generation, missing-modality MR synthesis, and MR-to-CT synthesis. The authors also provide ablations.

The paper includes good implementation details and optimizer settings, learning rates, batch sizes, training steps, loss weights, memory-efficient two-pass inference, and memorization probes are all described. The appendix also contain CIs and statistical tests such as the paired Wilcoxon tests for missing-MR and MR-to-CT ablations.

Weaknesses

SOTA and novelty
While the paper is clearly written, it is hard to judge the novelty and impact, as several SOTA models for 3D medical image generation seem to be missing in the benchmarks, particularly 3D diffusion models. One of the major claims of the paper is the high performance in relation to compute and inference time. However, several diffusion models have gained significant performance optimizations during the last two years; for example MAISI-v2 [1], which is 33 times faster than v1 while maintaining or even improving quality metrics. Another example of a model that can be executed on a 24GB GPU with reasonable inference time is 3D MedDiffusion [2]. In addition there seem to be several attempts at speeding up cWDM in particular, which is the major baseline for missing-MR synthesis - and against which the main claim of speed ups come from (for example Fast-cWDM that claims significant speed up). Also a minor issue: that the statistical test reject a difference is not evidence of equivalence or non-inferiority, for example, the cWDM average is slightly better in both PSNR and SSIM.

Looking at the 2D-to-3D methods, the paper cites Make-A-Volume and TCAM-diff. Make-A-Volume is very similar in that it uses 2D backbones and adds volumetric layers to mitigate incosistencies. TCAM-diff uses triplane representations to reduce memory for high resloution 3D generation. LiFT seem to be meaningfully different from these in that it is more assymetric (as the paper states), i.e. most capacity remains in the 2D model, and the learned 3D component is a small trajectory/context module rather than a volumetric decoder or triplane diffusion model. Still, from my understanding, the novelty gap might be narrower than the paper suggets, especially for LiFT-C, where a BIGRU over slice features is very similar to a sequence-context wrapper around a 2D translator.

[1] Zhao, Can, et al. "Maisi-v2: Accelerated 3d high-resolution medical image synthesis with rectified flow and region-specific contrastive loss." Proceedings of the AAAI Conference on Artificial Intelligence. Vol. 40. No. 15. 2026.

[2] Wang, Haoshen, et al. "3D MedDiffusion: A 3D medical latent diffusion model for controllable and high-quality medical image generation." IEEE Transactions on Medical Imaging (2025).

Clinical grounding and validation
For MR-to-CT, the authors use SynthRAD2023 which is a large multi-center challenge with 540 instances for MR-to-CT. The challenge contain both image similarity and dose.based metrics, and many valid submissions. The challenge report explicitly notes that image similarity did not sginificantly correlate with dose accuracy, which makes dose evaluation important for clinical sCT claims. This paper evaluates only on an 80/20 split of 180 public brain subjects (cropped to 128³) and compares mainly to pix2pix variants plus a reimplemented CBAM3D-UNet. While useful for the ablation study it is hard to draw any further conclusions against other SynthRAD participants. The authors acknowledges that the evaluation is image-domain only, but I cannot find a reason for why the full evaluation protocol was not used (other than stating it is out of scope).

LiFT-U reports very impressive results compared to WDM on BraTS GLI, with much lower MS-SSIM and only using 0.41GB inference memory. However, again, it is hard to say anything about the clinical utility. Tri-planar marginal feature matching can look good under a feature based FID without proving that the 3D anatomy is valid. The method aligns generated and real slices in axial/coronal/sagittal feature spaces, but a distribution that matches all three sets of 2D projections can still have unrealistic joint 3D topology, tumor morphology, or long-range dependencies (see e.g. [3] or [4]). The qualitative reformats and PCA trajectories help, but they do not establish anatomical validity. The PCA plots show smooth context trajectories, not necessarily correct anatomy. The paper should add real-vs-real calibration for FID/MS-SSIM (right now it is hard to assess how close LiFT-U is to the intrinsic variability of the dataset), KID or precision/recall-style metrics, disease-region or tumor shape statistics, automated segmentation consistency (this is specifically mentioned to be out of scope, but why?) or similar. Ideally also a blinded user review, but this is challenging without access to clinicians, and is also mentioned to be out of scope (which is more understandable, but done in other studies like e.g. [2]).

I understand that this might seem excessive, but the method is specifically targeting the medical domain, and clinical utility is thus important.

[3] Cohen, Joseph Paul, Margaux Luck, and Sina Honari. "Distribution matching losses can hallucinate features in medical image translation." International conference on medical image computing and computer-assisted intervention. Cham: Springer International Publishing, 2018.

[4] Usman Akbar, Muhammad, et al. "Brain tumor segmentation using synthetic MR images-A comparison of GANs and diffusion models." Scientific Data 11.1 (2024): 259.

Questions
  1. Could the authors benchmark against more recent baselines like e.g. MAISI-v2 and 3D MedDiffusion (or other more recent models with similar performance)?
  2. Could the authors run the complete SynthRAD testing protocol?
  3. Could the authors add additional testing metrics (as listed under weaknesses) + real-vs-real calibration, or otherwise motivate clinical utility?
  4. Is it possible to further expand on the real differences between LiFT and Make-A-Volume (other than the different backbone and loss function)?
Limitations

The authors do discuss limitations, but just stating that clinical utility is out of scope is not sufficient given that the paper evaluates clinically motivated tasks.

Final justification

After considering the rebuttal and subsequent discussion, I increase my overall score from 3 to 4. The authors have substantially addressed my main empirical concerns. In particular, they provide matched evaluations of MAISI-v2, 3D MedDiffusion, cWDM, and Fast-cWDM on the same datasets and metric pipelines. These results support the narrower and more defensible claim that LiFT provides competitive image quality at substantially lower inference cost. They also correct the interpretation of the nonsignificant cWDM comparisons, provide paired confidence bounds and significance analyses, explain the discrepancy between the original and official SynthRAD metrics, and clarify the architectural distinction from Make-A-Volume and TCAM-Diff.

The added real-vs-real calibration, precision/recall/coverage metrics, shuffled-volume controls, coarse anatomical measures, and lesion-region analysis materially improve the evaluation. In particular, the negative controls support the claim that the proposed metrics detect gross slice-ordering failures, while the lesion-region results provide evidence that the paired mapper improves through-plane reconstruction in pathological regions rather than only global image metrics.

Important limitations remain. Several central analyses were added only during discussion and are not yet documented in enough detail to assess training convergence, sampling configurations, repeated-run variability, and the exact real-vs-real calibration procedure. The new spatial LiFT-C configuration also differs from the pooled-descriptor design described in the submitted paper, so I place limited weight on improvements that depend on this post-submission architectural change. Moreover, the unconditional anatomical evaluation remains coarse: brain-mask consistency and symmetry do not establish detailed internal anatomy, tumour validity, or clinical utility. There is also no matched Make-A-Volume quality comparison or official SynthRAD dose evaluation.

A final manuscript needs to clearly document the new protocols, distinguishes submitted from revised model configurations, and scopes its conclusions to the evaluated brain-imaging tasks rather than universal SOTA or clinical validity.

Formatting concerns

No

6 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for the detailed review and for helping us strengthen the modern-baseline and clinical-evaluation discussion. We agree that our wording should distinguish more clearly between universal SOTA performance and the quality–efficiency trade-off that LiFT is designed to achieve. LiFT’s claim is competitive image quality at much lower inference cost, not the best image metric in every setting. We also agree that the nonsignificant paired Wilcoxon result does not establish equivalence or non-inferiority. We are re-evaluating the comparison with a formal equivalence/non-inferiority test and do not interpret the current p-values as evidence of equivalence.

1. Recent baselines. We appreciate the request for comparisons with more recent efficient models. The verified comparisons and current evaluation status are summarized below:

Model FID (x10^3) ↓ Time / volume ↓ Parameters
LiFT-U 0.066 0.039 s 30.3M
MAISI-v2 0.294 0.506 s 201.4M
3D MedDiffusion training 15.37 s 166.3M

All timings above were measured on an NVIDIA RTX 5090. Matched Fast-cWDM evaluations for all four missing-MR targets are also in progress. We will share the verified 3D MedDiffusion and Fast-cWDM quality results as soon as they are available.

2. SynthRAD protocol. For SynthRAD, we use an 80/20 patient-level split of the public brain MR-to-CT cohort and evaluate all models on the same held-out subjects with the official SynthRAD image-metric implementation (MAE, PSNR, and SSIM):

Model MAE ↓ PSNR ↑ SSIM ↑
pix2pix-UNet 74.06 26.93 0.8872
CBAM3D-UNet 60.94 28.30 0.9201
pix2pix-ResNet 55.21 29.08 0.9287
LiFT-C without mapper 56.01 28.84 0.9301
LiFT-C 54.04 29.10 0.9357

Under this controlled evaluation, LiFT-C gives the best MAE, PSNR, and SSIM among the models listed and improves all three metrics over the no-mapper control. We chose this matched comparison rather than relying only on a leaderboard submission, because it allows the baselines and ablation to be evaluated under identical data and metric settings.

The hidden-test CTs and patient-specific treatment-planning files are embargoed, so the dose analysis cannot be reproduced locally. A challenge submission could provide a leaderboard score for LiFT, but the submission limit would not allow the same controlled multi-baseline evaluation. These are therefore internal test-split results, not official leaderboard or dose-validation results.

3. Additional metrics and medical scope. FID alone is not enough to establish anatomical or clinical validity. For the paired tasks, we evaluate the quantity that LiFT is designed to improve: through-plane consistency. This includes plane-wise SSIM, adjacent-slice derivative error, derivative correlation, and region-specific MR-to-CT errors. On MR-to-CT, the mapper reduces regional through-plane derivative error by ~9–12%, a larger change than the improvement in voxel MAE.

For unconditional medical generation, we are working on a broader evaluation protocol that considers fidelity, distributional coverage, anatomical plausibility, and through-plane coherence.

The paper evaluates a synthesis method on medical imaging tasks; it is not a clinical validation study. Tumor-shape analysis, segmentation consistency, reader studies, and dose evaluation would be needed before making clinical-use claims.

4. Difference from Make-A-Volume. The cleanest distinction is where the cross-slice computation lives. Make-A-Volume inserts pseudo-3D cross-slice layers into a 2D latent-diffusion backbone, so slices interact during denoising.

LiFT instead leaves the 2D synthesis path intact and confines cross-slice communication to a small trajectory or bottleneck module. In LiFT-U, the depth mapper produces one conditioning vector per depth for a frozen 2D generator; it does not apply volumetric convolutions to full spatial feature maps. In LiFT-C, recurrence is confined to the bottleneck and injects a context representation before the unchanged 2D decoder and skip pathways. The volume is then generated in one non-iterative pass.

We appreciate these requests, which help us state the scope of the contribution more precisely and strengthen the evidence around efficiency, medical evaluation, and related work.

Reviewer kg5B · CommentOpenReview ↗

Thank you for the response, it clarifies that the intended claim is a quality-efficiency trade-off rather than universal SOTA, and provides clarifications on architectural distinctions from Make-A-Volume. The new benchmarks are potentially important, but hard to judge without more details, e.g. whether MAISI-v2 was tuned on BraTS T1n etc, and some SOTA comparisons remain in progress. The new SynthRad results are also interesting and while numerically true that LiFT-C seem to have the highest scores, the differences are small enough that it could be well within the variance. Also these rebuttal numbers differ substantially from Table 6. Finally, the response acknowledges that FID is insufficient for anatomical validity but provides no new unconditional anatomy/pathology-aware metrics or real-vs-real calibration. I therefore view the rebuttal positively but retain my overall rating of 3, while increasing my assessment of the potential significance of the efficiency result.

Authors · CommentOpenReview ↗

Response 1/4

Thank you for the follow-up and for identifying the additional details needed to assess the new results. Below, we present the results and analyses completed since our previous response to address the remaining concerns.

Recent-baseline protocol and completed results. Models compared below were trained on the same BraTS T1n training split at (128^3); the 219 held-out subjects were used only for final evaluation. All unconditional models were evaluated against the same held-out real reference using identical MedicalNet feature extraction and metric code. MAISI-v2 and 3D MedDiffusion were retrained on this split rather than used off-the-shelf; for MAISI-v2 we ran both from-scratch and warm-started training and report the better of the two.

Model FID ×10³ Recall Precision Coverage Time/volume Parameters
Real held-out calibration 0.056 0.890 0.904 0.954 — —
LiFT-U 0.086 0.877 ± 0.016 0.977 0.990 0.039 s 30.3 M
3D MedDiffusion 0.085 0.861 ± 0.026 0.935 0.963 15.37 s 166.3 M
MAISI-v2 0.279 0.616 ± 0.043 0.902 0.794 0.506 s 201.4 M

LiFT-U obtains essentially the same FID as 3D MedDiffusion while being approximately 394× faster and using 5.5× fewer parameters. Relative to the real-data calibration, LiFT-U achieves recall 0.877 versus 0.890, precision 0.977 versus 0.904, and coverage 0.990 versus 0.954. The FID values differ from our preliminary response because all methods were reevaluated against the same 219-subject real reference used for the real-versus-real calibration.

Consolidated design. The submitted missing-MR model used recurrence over pooled slice descriptors, whereas the MR-to-CT model used a spatial bottleneck map. In analysis performed in response to the lesion-fidelity question, a linear probe showed that the spatial representation preserves within-slice lesion localization (per-pixel tumour-occupancy AUC 0.973). We therefore standardized both tasks on the spatial configuration for the new analyses reported below. This raises the missing-MR average PSNR from 28.31 dB for the submitted pooled configuration to 28.42 dB for the spatial configuration, while leaving the quality–efficiency conclusion unchanged.

We also completed our matched Fast-cWDM evaluation on all 219 held-out subjects and all four missing-MR targets. All methods use identical preprocessing and metric code.

Model Avg. PSNR Avg. SSIM Time/volume Parameters Steps
LiFT-C 28.417 0.9528 1.159 s 41.3 M 1
cWDM 28.425 0.9525 156.4 s 81.5 M 1000
Fast-cWDM 28.233 0.9456 15.53 s 81.5 M 100

LiFT-C differs from cWDM by 0.008 dB in average PSNR, slightly exceeds it in average SSIM, and is 135× faster. Compared with Fast-cWDM, LiFT-C improves average PSNR by 0.184 dB and SSIM by 0.0072 while being 13.4× faster and using about half the parameters. Fast-cWDM trains and samples with 100 rather than 1000 steps while retaining the same 81.5 M-parameter network, whereas LiFT-C synthesizes the volume in a single pass. The reconstruction-quality differences between LiFT-C and cWDM are small. Our claim is that LiFT achieves competitive quality with substantially lower computational cost, not that it is superior on every reconstruction metric.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…