potentialpaper

Sparse Multimodal Switching State-Space Models for Regime-Dependent Neural Connectivity under Partial Observations

R. K. Sharma, Feng Liu, Xiaochen Xian

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. This paper develops a sparse multimodal switching state-space model for regime-dependent directed connectivity inference of joint EEG–iEEG recordings, with application to epilepsy-related neural dynamics.

Abstract. The directed coupling between brain regions constitutes a high-dimensional connectivity network that can change substantially across dynamical regimes (e.g., pre-seizure, ictal, and post-seizure states). Statistically quantifying changes in these networks across regimes can help neuroscience researchers better understand brain dynamics over time. However, this quantification is challenging: multimodal electrophysiological recordings can only partially observe the underlying neural dynamics, these dynamics switch among unobserved regimes, and the candidate interactions are many but sparse. Joint scalp electroencephalography (EEG) and intracranial EEG (iEEG) provide complementary information for this task: EEG offers broad but spatially mixed coverage, whereas iEEG provides high-fidelity observations at sparsely sampled locations. We propose the Sparse Multimodal Switching State-Space Model (S$^4$M$^3$), a unified framework for fusing these observations to estimate sparse directed source-space networks and statistically assess their regime-dependent changes. The model links both modalities to a shared latent source process governed by regime-specific sparse transition matrices. An approximate expectation-maximization algorithm combines Kim filtering and RTS smoothing with an elastic-net penalty to jointly estimate source activity, regimes, and sparse directed networks. To address the shrinkage bias of the elastic-net sparsity penalty, we separate edge selection from edge assessment: selected edges are refit by regime-weighted least squares, followed by Wald tests with Benjamini-Hochberg correction. On the synthetic benchmark, S$^4$M$^3$ improves edge F1F_1 by approximately 25% over the strongest evaluated stationary baseline and 64% over the best evaluated two-stage source-connectivity pipeline. In a real EEG-iEEG epilepsy case study, S$^4$M$^3$ identifies regime-dependent pathway changes involving the left hippocampus, the clinician-confirmed seizure-onset region, without using clinical labels.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
5 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]—[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:47 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

This paper proposes a sparse state-space model for inferring regime-dependent directed connectivity from joint EEG and intracranial EEG recordings.

Strengths:

  • Technically rigorous (xZKZ, LgKk, We1C)
  • Careful synthetic evaluation, including ablations and robustness analyses (xZKZ, LgKk)
  • Addresses an important multimodal neural data analysis problem with a principled probabilistic framework (LgKk, We1C)

Weaknesses:

  • The methodological novelty beyond existing switching state-space models and sparse estimation techniques could clarified (xZKZ, We1C)
  • Evaluation on real data could be strengthened by additional baselines and analyses (LgKk, We1C)
  • Generality of the proposed framework should be clarified, particularly beyond the epilepsy application (xZKZ, LgKk)
  • Would benefit from clearer exposition of the inference procedure, background material, and key definitions (xZKZ, We1C)

Weaknesses that, if addressed, might significantly change the odds of acceptance:

  • Better clarify the methodological novelty relative to prior switching state-space models and multimodal connectivity estimation approaches. (xZKZ, We1C)
  • Strengthen the empirical validation through additional real-data baselines, broader synthetic evaluations, and discussion of how the framework generalizes beyond the current setting. (xZKZ, LgKk, We1C)

Overall, the reviewers agreed that the paper presents a technically sound framework with careful methodological development and promising empirical results, but felt that the paper would benefit from a clearer articulation of its methodological novelty and a stronger empirical validation on real data.

Final justification

I have read the authors' response and the reviewers' assessments following the rebuttal. The authors provided substantial additional experiments and clarification addressing the empirical validation, scope, and positioning of the method. Reviewers LgKk and We1C felt that their concerns were largely or fully addressed, while xZKZ remained unconvinced that the work provides sufficient methodological novelty. Overall, I believe the rebuttal substantially strengthened the paper and addressed most of the concerns raised in the initial reviews.

Area Chair ig3z · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

This paper proposes a sparse state-space model for inferring regime-dependent directed connectivity from joint EEG and intracranial EEG recordings.

Strengths:

  • Technically rigorous (xZKZ, LgKk, We1C)
  • Careful synthetic evaluation, including ablations and robustness analyses (xZKZ, LgKk)
  • Addresses an important multimodal neural data analysis problem with a principled probabilistic framework (LgKk, We1C)

Weaknesses:

  • The methodological novelty beyond existing switching state-space models and sparse estimation techniques could clarified (xZKZ, We1C)
  • Evaluation on real data could be strengthened by additional baselines and analyses (LgKk, We1C)
  • Generality of the proposed framework should be clarified, particularly beyond the epilepsy application (xZKZ, LgKk)
  • Would benefit from clearer exposition of the inference procedure, background material, and key definitions (xZKZ, We1C)

Weaknesses that, if addressed, might significantly change the odds of acceptance:

  • Better clarify the methodological novelty relative to prior switching state-space models and multimodal connectivity estimation approaches. (xZKZ, We1C)
  • Strengthen the empirical validation through additional real-data baselines, broader synthetic evaluations, and discussion of how the framework generalizes beyond the current setting. (xZKZ, LgKk, We1C)

Overall, the reviewers agreed that the paper presents a technically sound framework with careful methodological development and promising empirical results, but felt that the paper would benefit from a clearer articulation of its methodological novelty and a stronger empirical validation on real data.

Final justification

I have read the authors' response and the reviewers' assessments following the rebuttal. The authors provided substantial additional experiments and clarification addressing the empirical validation, scope, and positioning of the method. Reviewers LgKk and We1C felt that their concerns were largely or fully addressed, while xZKZ remained unconvinced that the work provides sufficient methodological novelty. Overall, I believe the rebuttal substantially strengthened the paper and addressed most of the concerns raised in the initial reviews.

1 comment
Authors · CommentOpenReview ↗

We thank the AC for the clear summary of the reviewers’ concerns. We have addressed each of the points raised in our rebuttals to Reviewers xZKZ, LgKk, and We1C.

For methodological novelty, please see our responses to Reviewer xZKZ under "1. Methodological novelty and multimodal specificity" and to Reviewer We1C under "Q2. Novelty and contributions beyond existing switching models."

Unlike standard switching state-space models, which primarily recover latent states and regime transitions, S4M3S^4M^3 directly infers sparse, anatomically indexed, regime-specific directed networks and the pathway changes between them. It therefore not only detects when the dynamics change, but also identifies which anatomical pathways change, estimates the sign and magnitude of those changes, and assesses them while accounting for uncertainty and multiplicity.

We supported this distinction in three ways:

  1. Positioning against prior models: the comparison table clarifies how S4M3S^4M^3 differs from representative switching, sparse, and multimodal model classes.

  2. Formal justification of multimodal specificity: Proposition 1 shows that EEG and iEEG can reduce complementary unobservable subspaces, establishing that the multimodal contribution goes beyond observation stacking.

  3. Empirical validation of the mechanism: the coverage-stratified experiment shows that the largest gains occur when the two modalities constrain complementary parts of a directed pathway.

For stronger empirical validation, please see our response to Reviewer We1C under "Q1. Expanded real-data evaluation, baselines, and sensitivity." We added EEG-only and iEEG-only switching baselines, a fixed-window dual baseline, a multi-population rSLDS comparison, and analyses of initialization robustness, elastic-net sensitivity, and source-space resolution. Broader synthetic experiments and direct latent-state recovery are presented in our response to Reviewer xZKZ under "4. Broader synthetic evaluation and latent-state recovery." The three-regime evaluation and extension of the assessment framework to general JJ are discussed in our response to Reviewer LgKk under "Q2. General JJ-regime formulation and three-regime evaluation."

For generality beyond epilepsy, please see our response to Reviewer xZKZ under "3. Intended scope, limitations, future work, and relation to CREIMBO." There, we clarify that the framework applies more broadly to synchronized multimodal observations of a shared latent process with approximately piecewise-stationary dynamics.

Finally, the inference and exposition concerns are addressed in our response to Reviewer xZKZ under "2. E-step explanation and manuscript organization" and in the "Minor Weaknesses" section.

We hope these additions clarify the paper’s methodological contribution, strengthen its empirical support, and directly address the concerns highlighted in the meta-review.

Reviewer We1COpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
2/4
Significance
2/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper proposes Sparse Multimodal Switching State-Space Model (S4M3), a method for analyzing joint scalp EEG-intracranial EEG recordings. The paper identifies three main challenges in analyzing such recordings: partial-observability, nonstationarity, and sparsity. S4M3 tackles each challenge by adding a switching capability and elastic-net sparsity penalty to the model. The paper derives an EM algorithm for inference and parameter estimation. S4M3 is compared with other methods on a synthetic dataset whose ground truth regime and dynamics are known, and is applied to a real EEG dataset.

Strengths and weaknesses

Quality: The submission is technically sound, with appropriate explanations throughout the paper. The methods section is particularly well-written in great detail, with supporting sections in the Appendix. The claims are well supported by experimental results, though I think the real data experiment could be improved with additional baselines (see Questions below).

Clarity: Although the paper is generally well-written, I think the paper needs a more concise abstract and Introduction, as they’re currently too dense. In addition, I think the paper would benefit from having a technical background section on switching models (e.g., switching linear dynamical system), elastic-net sparsity penalty, and other key techniques used throughout the paper. In addition, the Figure legends and labels are too small, making it hard to read.

Significance: The paper could be of interest to the community interested in EEG analysis, and it’s well supported by S4M3’s performance on synthetic dataset. However, the paper lacks comparison with other baseline methods for the real data experiment, which could make the community question the results for the real data experiment.

Originality: The paper lacks originality, as it mostly builds on top of existing methods, such as switching models and elastic-net sparsity penalty.

Questions
  • The paper currently shows the results from S4M3 for the real EEG-iEEG recording experiment. Although the authors make a note that the findings from S4M3 are interpretable and are in line with the clinical results, it’s hard to say whether this result was only possible because of the proposed method. How sensitive is the result to the hyperparameters of S4M3, and how are the hyperparameters chosen? In addition, could we apply existing methods such as the multi-population recurrent switching linear dynamical systems (Glaser et al. 2020 cited as [3] in the paper) and compare the results?

  • Could you further clarify the key contributions and novelty on top of the existing switching models?

  • (Minor) How efficient is the current S4M3 implementation? How well does S4M3 scale to larger EEG-iEEG datasets, with more timesteps, etc?

Limitations

Yes

Final justification

The authors addressed my questions and concerns with additional experiments and explanations. Thus, I raise my score to 4.

Formatting concerns

No concerns.

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

1. Strengths and Weaknesses

We thank the reviewer for recognizing the paper’s strengths. We address the real-data concern in Q1 and will shorten the opening sections, add brief methodological background, and enlarge figure text. As clarified in Q2, the contribution is unified estimation and assessment of sparse regime-dependent network contrasts under multimodal partial observation.

2. Questions

Q1. Expanded real-data evaluation, baselines, and sensitivity

We expanded the Patient #1 simultaneous EEG-iEEG analysis by comparing S4M3S^4M^3 with EEG-only and iEEG-only switching models, a prespecified 70/30 fixed-window dual baseline, and a multi-population rSLDS. We also performed 50-initialization robustness, elastic-net sensitivity, and source-resolution analyses. Directly comparable models use the same preprocessing, anatomically anchored N=12N=12 source space, regularization, and select-refit-assess procedure. The clinician-confirmed SOZ (Hippocampus L; Hipp. L hereafter) was used only post hoc as an external qualitative reference.

Initialization robustness. Each switching model used 50 random initializations. A fit was valid if its final observed-data likelihood was finite and ρ(Φ^j)<1\rho(\widehat{\Phi}^j)<1 for both regimes. The dual model produced 32 valid fits with median support 16.5 and a sparse distributed network. EEG-only produced 44 valid fits with median support 0 and no off-diagonal pathways; iEEG-only produced 14 valid fits with median support 32 and a denser mesial-temporal network. The fixed-window baseline produced a dense early-late contrast with support 58. The representative fit was the valid initialization with the highest observed-data likelihood.

Highest-ranked directed pathways. Pathways are ranked by absolute edge-level Wald statistic after unpenalized refitting; pBHp_{\mathrm{BH}} is the BH-adjusted pp-value, and Hipp. L indicates whether Hipp. L is an endpoint.

Model Directed pathway Wald (approx.) pBHp_{\mathrm{BH}} Significant Hipp.
Dual switching Hipp. L$\rightarrow$Lingual Gyrus 27 <0.001 Yes Yes
Temporal Fusiform (post.)→\rightarrowLingual Gyrus 14 0.009 Yes No
Parahippocampal Gyr. (post.)→\rightarrowLingual Gyrus 12 0.022 Yes No
Hipp. L$\rightarrow$Temporal Pole 11 0.030 Yes Yes
Temporal Fusiform (post.)→\rightarrowHipp. L 9 0.055 No Yes
Hipp. L pathways among top five 3/5
EEG-only switching No off-diagonal pathways selected in the representative valid fit --
iEEG-only switching Hipp. L$\rightarrow$Amygdala L 99.350 <10−20<10^-20 Yes Yes
Amygdala L$\rightarrow$Hipp. L 47.356 <10−9<10^-9 Yes Yes
Temporal Fusiform (post.)→\rightarrowAmygdala L 30.914 <10−6<10^-6 Yes No
Sup. Temporal Gyrus (ant.)→\rightarrowTemporal Pole 27.339 <10−5<10^-5 Yes No
Sup. Temporal Gyrus (ant.)→\rightarrowAmygdala L 15.725 3.22×10−43.22×10^-4 Yes No
Hipp. L pathways among top five 2/5
Fixed-window dual Sup. Temporal Gyrus (ant.)→\rightarrowParahippocampal Gyr. (post.) 281.369 <10−60<10^-60 Yes No
Mid Temporal Gyrus (ant.)→\rightarrowParahippocampal Gyr. (post.) 181.341 <10−38<10^-38 Yes No
Temporal Pole$\rightarrow$Parahippocampal Gyr. (post.) 160.936 <10−34<10^-34 Yes No
Inf. Temporal Gyrus (ant.)→\rightarrowParahippocampal Gyr. (post.) 122.999 <10−26<10^-26 Yes No
Parahippocampal Gyr. (ant.)→\rightarrowAmygdala L 18.820 1.67×10−41.67×10^-4 Yes No
Hipp. L pathways among top five 0/5

Modality and temporal baselines. The dual model produced a sparse distributed network with 3/5 top pathways involving Hipp. L. EEG-only selected no off-diagonal pathways; iEEG-only emphasized local Hipp. L–Amygdala L connectivity, and the denser fixed-window network had no top-five Hipp. L pathway. Thus, the dual model combined local intracranial and broader source-space information.

Comparison with multi-population rSLDS. rSLDS detected a sustained regime change at 1.548 s, supporting a nontrivial transition. However, its population-level latent coordinates are not anatomically indexed, so its dynamics cannot be mapped directly to specific sources or pathways. We therefore use rSLDS for regime detection, whereas S4M3S^4M^3 localizes pathway changes and assesses them statistically.

Elastic-net sensitivity. The nominal (λ,α)(\lambda,\alpha) pair was selected by observed-data likelihood; neighboring values assessed sensitivity. We evaluated λ=(0.0005,0.001,0.002)\lambda=(0.0005,0.001,0.002) and α=(0.90,0.95,0.98)\alpha=(0.90,0.95,0.98) with 10 initializations each. Results were more sensitive to λ\lambda. At λ=0.0005\lambda=0.0005, 8–10/10 fits were valid and Hipp. L appeared among the top five in nearly every fit. At λ=0.001\lambda=0.001, 5–6/10 were valid but Hipp. L involvement persisted. At λ=0.002\lambda=0.002, only 0–1/10 were valid, indicating over-regularization. Median support decreased from about 28–31 to 16–19 as λ\lambda increased, whereas α\alpha had little effect. The Hipp. L-centered interpretation was therefore stable over the usable range.

Source-space resolution. We repeated the dual analysis at N=30N=30 and 4040. Hipp. L remained involved, appearing in one top pathway at N=30N=30 and two at N=40N=40. Exact pathways varied with anatomical granularity, as expected because each parcellation defines a different estimand.

Q2. Novelty and contributions beyond existing switching models

The novelty of S4M3S^4M^3 lies in combining anatomically anchored multimodal inference, sparse regime-specific network estimation, and post-selection assessment of cross-regime pathway changes.

Regime-specific anatomical networks as inferential targets. The primary estimands are the directed networks Φj\Phi^j and their contrasts, such as Δ=Φ1−Φ0\Delta=\Phi^1-\Phi^0. As summarized below, S4M3S^4M^3 jointly infers anatomically anchored latent sources, discrete regimes, and sparse regime-specific networks under one likelihood. It therefore identifies which directed pathways change across regimes, estimates the sign and magnitude of those changes, and ranks them after uncertainty and multiplicity adjustment.

Model Latent/partial Multimodal Switching network Network target Contrast assessment
MS-VAR ✗ ✗ ✓ ✗ ✗
Variational SSM ✓ ✗ ✓ ✗ ✗
rSLDS ✓ ✗ ✓ ✗ ✗
Sparse VAR ✗ ✗ ✗ Static ✗
DCM ✓ Sometimes ✗ Static ✗
Two-stage connectivity Indirect Sometimes Usually no Static Post hoc
Stationary EEG-iEEG SSM ✓ ✓ ✗ Static ✗
S4M3S^4M^3 ✓ ✓ ✓ Per regime ✓

Multimodal fusion under complementary partial observation. The multimodal contribution is not merely observation stacking. S4M3S^4M^3 links EEG and iEEG to the same anatomically anchored latent process through distinct modality-specific operators. EEG provides broad but spatially mixed coverage, whereas iEEG provides sparse, locally precise measurements. Their joint use can reduce modality-specific unobservable subspaces, as formalized below. This complementarity has a precise observability consequence.

Proposition 1 (Complementary multimodal observability). For regime jj, let OEjO_E^j and OIjO_I^j denote the observability matrices associated with LL and CC, and define OEIj=[OEj;OIj]O_{EI}^j=[O_E^j;O_I^j]. Then null(OEIj)=null(OEj)∩null(OIj)null(O_{EI}^j)=null(O_E^j)\cap null(O_I^j) and rank(OEIj)≥max⁡(rank(OEj),rank(OIj))rank(O_{EI}^j)\geq\max(rank(O_E^j),rank(O_I^j)). Hence, the joint system is observable whenever the modality-specific null spaces intersect only at 0\mathbf{0}, even if neither modality is individually observable.

The result follows because OEIjv=0O_{EI}^jv=0 if and only if both OEjv=0O_E^jv=0 and OIjv=0O_I^jv=0.

We evaluated this complementarity in a 30-trial coverage-stratified synthetic experiment. Edges were grouped by whether their source and target regions were directly sampled by iEEG (covered) or not (uncovered). For covered-covered edges, the dual model achieved F1=0.838F_1=0.838, versus 0.7190.719 for iEEG-only and 0.1820.182 for EEG-only, with paired gain 0.139[0.090,0.195]0.139 [0.090,0.195]. When only the source or target was covered, iEEG-only achieved F1=0F_1=0, whereas the dual model achieved 0.3670.367 and 0.3630.363, with gains 0.207[0.129,0.290]0.207 [0.129,0.290] and 0.340[0.233,0.451]0.340 [0.233,0.451], respectively. The largest gains occurred when iEEG constrained one endpoint and EEG informed the other, directly matching the complementary-coverage mechanism described by Proposition 1.

Post-selection assessment of pathway changes. Existing switching models generally do not provide pathway-level assessment of cross-regime contrasts because their latent coordinates may not be anatomically anchored, their transition matrices are treated primarily as predictive parameters, or support selection is not separated from uncertainty quantification. Because penalization induces shrinkage bias, direct Wald testing of the penalized coefficients is unsuitable. S4M3S^4M^3 instead combines penalized support selection, unpenalized refitting, fixed-support large-sample Wald assessment, and multiplicity correction, yielding sparse pathway discovery with approximate evidence for regime-dependent change.

Q3. (Minor) Efficiency and scalability

The per-iteration cost is

O(TJ2(N3+MN2+M3)+TJN2+JNs2),\mathcal{O}\left(TJ^2(N^3+MN^2+M^3)+TJN^2+JNs^2\right),

where JJ, NN, MM, and s≪Ns\ll N denote the numbers of regimes, latent sources, observed channels, and active coefficients per row, respectively. Runtime is approximately linear in TT but more demanding in NN because of latent covariance operations.

On a 64 GB CPU workstation, runtime increased from 734734 s at N=20N=20 to 10881088, 15571557, and 24552455 s at N=40N=40, 6060, and 8080. Edge F1F_1 was 0.5720.572 at N=40N=40 and 6060, decreasing to 0.5000.500 at N=80N=80. Thus, the implementation is practical for moderate source spaces, while high-resolution models remain the main computational bottleneck. Derivations and results are in Appendices C and H.

Reviewer We1C · CommentOpenReview ↗

I would like to thank the authors for a thoughtful response to my questions and for running additional experiments. My concerns in the original comment are mostly well addressed. Thus, I am happy to raise my score.

Authors · CommentOpenReview ↗

We thank the reviewer for reconsidering the submission and for recognizing that our response and additional experiments addressed the main concerns. We appreciate the constructive feedback, which will help us improve the clarity and empirical presentation of the final manuscript.

Reviewer LgKkOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
4/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The proposed methodology seeks to leverage datasets in which simultaneous EEG and iEEG observations are available in order to identify source-space directed connectivity dynamics from multimodal data. An expectation-maximization algorithm is proposed to simultaneously identify connectivity patterns in different regimes (i.e. brain states) and transitions/differences between these regimes; accompanying statistical tests for assessing the significance of changes in detected edges are also proposed. Validations on synthetic datasets against appropriate benchmarks show the proposed method’s efficacy, but there remain some aspects of model validation that would be useful to address.

Strengths and weaknesses

• Strengths: The proposed methods are rigorously developed and key issues such as complexity and identifiability are addressed specifically. Algorithms for initialization also provide a useful tool for reproducibility. Benchmarking on synthetic datasets is rigorous as well, though there are additional questions that are unaddressed. • Weaknesses: Statistical testing of network differences across regimes is only explored for the two-regime case. It seems that extrapolation to more regimes might be non-trivial, given corrections for multiple comparisons seem to be necessary (e.g. pairwise significant differences between j=0,1,2,…). Accompanying the model formulation provided for the general case exactly would make the contribution of this work more complete. Additionally, assessment of network differences is based on all detected edges in each regime rather than only the significant ones, which might misrepresent the extent of network differences.

Questions

• Tracking dynamics of networks across regimes seem very much related to the problem addressed in previous work here [1,2], and a comparison to the proposed methods would be good to mention in the first section of related works discussed. • The proposed work considers J regimes, but only quantifies edge-level differences between two. I understand that the validation is based on data in which J=2, but in the general case for which the rest of the methodology is developed, what is the motivation for only assessing the contrast between regimes j=0 and j=1? Wouldn’t the contrast between other combinations of regimes also be of interest, and how would the edge assessment procedure need to modified for the general case? Could this be examined in a synthetic dataset? • The assessment of significant network changes is applied to the contrast between two networks. However, the edges in networks in each regime are not assessed for significance first; might this not overestimate regime differences? • Sources are distributed across the brain and iEEG is locally observed (so the corresponding portion of the observation matrix would have its energy concentrated on a subset of the source space); would the proposed dual-modality approach better improve edge detection of sources jointly observed by both EEG and iEEG? That is, beyond the ablation experiment, do edges originating at sources covered by iEEG tend to be selected and assessed with greater confidence in the dual-modality model? And at what spatial scale of the source localization would the dual-modality approach provide the best improvement over single-modality source-space network analysis? Again, studying this on a synthetic dataset would be of great interest.

[1]. J. Gaudreault, A. Saxena and H. Shimazaki, "Online Estimation of Multiple Dynamic Graphs in Pattern Sequences," 2019 International Joint Conference on Neural Networks (IJCNN), Budapest, Hungary, 2019, pp. 1-8, doi: 10.1109/IJCNN.2019.8852467. [2]. Ishihara, K., Shimazaki, H. State-space kinetic Ising model reveals task-dependent entropy flow in sparsely active nonequilibrium neuronal dynamics. Nat Commun 16, 10852 (2025). https://doi.org/10.1038/s41467-025-66669-w

Limitations

The dual-modality model proposed here is limited to two sets of continuous signals at the same temporal resolution, and assumes that regimes evolve at the same temporal resolution of the measurements. Other dual-modality settings, such as joint spiking and LFP signals, are not easily generalized to given the current formulation but would be of interest in future work. The inference procedure is limited to comparing two regimes; however, settings such as sleep studies require consideration of multiple regimes. Addressing how the edge assessment procedure generalizes to 3 or more regimes would be an important addition to the work.

Final justification

Thanks to the authors for conducting substantial further analyses to address issues raised by all reviewers. Confirming again that my concerns have been well addressed, and I retain my positive assessment of the submission.

Formatting concerns

N/A

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

1. Strengths and Weaknesses

We thank the reviewer for recognizing the rigor of the complexity and identifiability analysis and the reproducibility value of the initialization procedure. We also agree that the manuscript should more clearly address: (i) generalization of the assessment layer beyond two regimes, (ii) the distinction between testing cross-regime contrasts and testing regime-specific edges, (iii) closely related nonstationary network models, and (iv) the dependence of multimodal gains on iEEG coverage and source-space resolution. We address these points in the questions below.

2. Questions

Q1. Relation to Gaudreault et al. [1] and Ishihara and Shimazaki [2]

We thank the reviewer for identifying these closely related approaches to nonstationary neural-network estimation. We will discuss both prominently in Related Work.

Gaudreault et al. [1] estimate time-varying mixtures of undirected Ising-type graphs from directly observed binary activity using sequential Bayesian inference. Ishihara and Shimazaki [2] develop a state-space kinetic Ising model for directly observed spike trains, allowing firing rates and directed couplings to vary smoothly over time and enabling time-dependent entropy-flow analysis. Both approaches operate on directly observed binary neuronal activity.

S4M3S^4M^3, in contrast, models continuous latent source dynamics that are only partially observed through spatially mixed EEG and spatially sparse iEEG. Gaudreault et al. [1] represent nonstationarity through time-varying mixtures of undirected graphs, whereas the kinetic Ising model uses smoothly time-varying directed couplings. S4M3S^4M^3 assumes piecewise-stationary directed transition networks governed by a latent discrete regime and targets the sparse cross-regime contrast Δ(j,k)=Φj−Φk.\Delta^{(j,k)} = \Phi^j-\Phi^k. Its select--refit--assess procedure identifies which anatomically anchored directed interactions change across regimes. We will also note that smoothly time-varying coupling models motivate a natural extension beyond the current piecewise-stationary assumption.

Q2. General JJ-regime formulation and three-regime evaluation

The switching model and penalized EM estimator are defined for an arbitrary number of regimes JJ. The two-regime presentation reflects the motivating background-versus-pathological application rather than a restriction of the estimation framework.

For J>2J>2, define the pairwise transition-network contrasts Δ(j,k)=Φ(j)−Φ(k)\Delta^{(j,k)}=\Phi^{(j)}-\Phi^{(k)}, 0≤k<j≤J−10\leq k<j\leq J-1.

For each candidate edge, let rr denote the unpenalized refit and define Dp,n(j,k)=Φ^r(j)[p,n]−Φ^r(k)[p,n]D_{p,n}^{(j,k)}=\widehat{\Phi}_{r}^{(j)}[p,n] - \widehat{\Phi}_r^{(k)}[p,n]. The standardized contrast and Wald statistic are

Zp,n(j,k)=Dp,n(j,k)/SE[Dp,n(j,k)]Z_{p,n}^{(j,k)}=D_{p,n}^{(j,k)}/SE[D_{p,n}^{(j,k)}] and Wp,n(j,k)=(Zp,n(j,k))2W_{p,n}^{(j,k)}=(Z_{p,n}^{(j,k)})^2, respectively.

Multiplicity across the complete edge-contrast family {(p,n,j,k)}\{(p,n,j,k)\} can be controlled using a single global Benjamini-Hochberg correction under the usual dependence conditions. A more conservative alternative is a hierarchical procedure that first tests the edge-wise omnibus null H0:Φ(0)[p,n]=Φ(1)[p,n]=⋯=Φ(J−1)[p,n]H_0:\Phi^{(0)}[p,n]=\Phi^{(1)}[p,n]=\cdots=\Phi^{(J-1)}[p,n], followed by multiplicity-adjusted pairwise comparisons only for edges that reject the omnibus null. We will add this formulation to the Methods section and identify the two-regime case as the special contrast (j,k)=(1,0)(j,k)=(1,0).

For each pair (j,k)(j,k), an edge (p,n)(p,n) is included in the candidate support S(j,k)S^{(j,k)} when ∣Δ^pen(j,k)[p,n]∣>τΔ|\widehat{\Delta}{pen}^{(j,k)}[p,n]| \gt \tau_{\Delta} and p≠np\ne n. Only these candidates are refitted without shrinkage and subjected to Wald assessment and multiplicity correction.

We additionally evaluated a three-regime process with repeated transitions: baseline →\rightarrow focal →\rightarrow distributed →\rightarrow focal →\rightarrow baseline. The experiment included single-hub, two-hub, bidirectional, and mixed-sign network changes. Regime accuracy remained between 0.970.97 and 0.980.98 in the single-hub, bidirectional, and mixed-sign settings, with edge F1F_1 between 0.370.37 and 0.410.41. The overlapping two-hub setting was substantially more difficult, yielding regime accuracy 0.77±0.050.77\pm0.05 and edge F1=0.18±0.03F_1=0.18\pm0.03.

These results demonstrate that the estimation framework can recover repeated multi-regime structure and regime-specific networks beyond J=2J=2, while also revealing reduced stability under strongly overlapping distributed dynamics. The generalized pairwise assessment follows from the formulation above; however, a complete empirical evaluation of all pairwise post-selection Wald assessments for J>2J>2 remains future work.

Q3. Why assess the cross-regime contrast directly?

Testing whether an edge changes across regimes differs from testing whether it is nonzero within each regime. The scientific null is H0:Φ(1)[p,n]−Φ(0)[p,n]=0H_0:\Phi^{(1)}[p,n]-\Phi^{(0)}[p,n]=0, which is not equivalent to separately testing Φ(0)[p,n]=0\Phi^{(0)}[p,n]=0 and Φ(1)[p,n]=0\Phi^{(1)}[p,n]=0.

An edge may be weak in both regimes yet have a well-estimated cross-regime difference; conversely, it may be strongly nonzero in both regimes but change little. Requiring regime-wise significance would therefore answer a different question and may discard genuine regime-dependent changes. Starting from the penalized contrast Δ^pen\widehat{\Delta}_{pen}, we select the candidate support SS refit Φ^r0\widehat{\Phi}_r^0 and Φ^r1\widehat{\Phi}_r^1, compute the Wald statistics, and apply BH correction. The final contrast network is not the union of regime-specific edges.

Q4. Coverage-specific multimodal gains and spatial scale

We designed a 30-trial coverage-stratified synthetic experiment. Under the convention Φmn:n→m\Phi_{mn}:n\rightarrow m, regime-changing edges were grouped according to whether their source and target regions were directly sampled by iEEG. The results are presented below.

Edge group Model Precision Recall F1F_1 Dual gain
Covered →\rightarrow covered EEG only 0.219±0.2330.219\pm0.233 0.167±0.1920.167\pm0.192 0.182±0.2020.182\pm0.202 --
Covered →\rightarrow covered iEEG only 0.585±0.1600.585\pm0.160 0.974±0.0620.974\pm0.062 0.719±0.1280.719\pm0.128 --
Covered →\rightarrow covered Dual EEG--iEEG 0.756±0.1650.756\pm0.165 0.966±0.0820.966\pm0.082 0.838±0.1230.838\pm0.123 0.139[0.090,0.195]0.139[0.090,0.195]
Covered →\rightarrow uncovered EEG only 0.129±0.1200.129\pm0.120 0.202±0.1890.202\pm0.189 0.148±0.1300.148\pm0.130 --
Covered →\rightarrow uncovered iEEG only 0.000±0.0000.000\pm0.000 0.000±0.0000.000\pm0.000 0.000±0.0000.000\pm0.000 --
Covered →\rightarrow uncovered Dual EEG--iEEG 0.276±0.1240.276\pm0.124 0.603±0.2290.603\pm0.229 0.367±0.1410.367\pm0.141 0.207[0.129,0.290]0.207[0.129,0.290]
Uncovered →\rightarrow covered EEG only 0.076±0.1440.076\pm0.144 0.065±0.1050.065\pm0.105 0.062±0.1000.062\pm0.100 --
Uncovered →\rightarrow covered iEEG only 0.000±0.0000.000\pm0.000 0.000±0.0000.000\pm0.000 0.000±0.0000.000\pm0.000 --
Uncovered →\rightarrow covered Dual EEG--iEEG 0.414±0.2930.414\pm0.293 0.345±0.2310.345\pm0.231 0.363±0.2380.363\pm0.238 0.340[0.233,0.451]0.340[0.233,0.451]
Uncovered →\rightarrow uncovered EEG only 0.045±0.0660.045\pm0.066 0.101±0.1310.101\pm0.131 0.056±0.0720.056\pm0.072 --
Uncovered →\rightarrow uncovered iEEG only 0.000±0.0000.000\pm0.000 0.000±0.0000.000\pm0.000 0.000±0.0000.000\pm0.000 --
Uncovered →\rightarrow uncovered Dual EEG--iEEG 0.122±0.1720.122\pm0.172 0.167±0.1540.167\pm0.154 0.126±0.1440.126\pm0.144 0.050[0.006,0.109]0.050[0.006,0.109]
All covered-origin edges EEG only 0.166±0.1220.166\pm0.122 0.185±0.1510.185\pm0.151 0.164±0.1260.164\pm0.126 --
All covered-origin edges iEEG only 0.585±0.1600.585\pm0.160 0.487±0.0310.487\pm0.031 0.522±0.0720.522\pm0.072 --
All covered-origin edges Dual EEG--iEEG 0.443±0.1210.443\pm0.121 0.784±0.1250.784\pm0.125 0.557±0.1120.557\pm0.112 0.047[0.009,0.084]0.047[0.009,0.084]

Coverage-stratified recovery of regime-dependent directed edges. The first and second labels denote iEEG coverage of the source and target regions, respectively. Dual gain is the paired improvement over the stronger unimodal F1F_1. Brackets report paired-bootstrap 95% confidence intervals.

The dual model achieved the highest F1F_1 in every coverage group. The largest gains occurred for uncovered-to-covered and covered-to-uncovered edges, where iEEG directly constrains one endpoint and EEG provides broader information about the other. The smallest gain occurred for uncovered-to-uncovered edges, where neither endpoint receives direct intracranial sampling. Even covered-to-covered edges improved by 0.1390.139, indicating that EEG contributes nonredundant information despite direct iEEG coverage.

For all edges originating from an iEEG-covered source, the dual model achieved F1=0.557F_1=0.557, compared with 0.5220.522 for iEEG-only and 0.1640.164 for EEG-only, with paired gain +0.047[0.009,0.084]+0.047 [0.009,0.084]. Thus, the dual model improves recovery even for covered-origin edges, although the largest relative gains occur when an edge spans the iEEG coverage boundary.

To examine spatial scale, we varied N=(20,40,60,80)N=(20,40,60,80), with the number of iEEG contacts scaled proportionally. The results are presented in Appendix H. Dual-model edge F1F_1 was 0.645±0.0620.645\pm0.062, 0.572±0.0600.572\pm0.060, 0.572±0.0650.572\pm0.065, and 0.500±0.0700.500\pm0.070, respectively. Absolute recovery therefore decreased as the source space became finer, with the strongest performance at N=20N=20. Because EEG-only and iEEG-only models were not repeated at every resolution, this experiment evaluates scalability and absolute recovery rather than the resolution with maximal relative multimodal gain.

[1]. J. Gaudreault, A. Saxena and H. Shimazaki, "Online Estimation of Multiple Dynamic Graphs in Pattern Sequences," 2019 International Joint Conference on Neural Networks (IJCNN), Budapest, Hungary, 2019, pp. 1-8, doi: 10.1109/IJCNN.2019.8852467.

[2]. Ishihara, K., Shimazaki, H. State-space kinetic Ising model reveals task-dependent entropy flow in sparsely active nonequilibrium neuronal dynamics. Nat Commun 16, 10852 (2025).

Reviewer LgKk · CommentOpenReview ↗

Acknowledgement of Authors' Responses

Thanks to the authors for their comprehensive responses; my concerns about the work have satisfactorily been addressed and I retain an overall positive view of the submission.

Authors · CommentOpenReview ↗

We thank the reviewer for the positive assessment and for confirming that our responses satisfactorily addressed the concerns. We appreciate the thoughtful comments, which will help us strengthen the final manuscript.

Reviewer xZKZOpenReview ↗
Rating
3/6
Confidence
3/5
Quality
2/4
Clarity
2/4
Significance
3/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper presents a new method, called S4M3S^4M^3, which is a switching state-space model for estimation of regime-dependent directed connectivity from joint EEG and intracranial EEG recordings. The presented model treats both modalities as linear observations of a shared latent process whose dynamics switch between regimes, each with its own sparse transition matrix. The model fitting is based on EM with a Kim filter/RTS smoother E-step and an elastic-net M-step. The method is validated on both synthetic data and real-world epilepsy recording.

Strengths and weaknesses

Strengths

  • The separation of the problem/model formulation from estimation is well-structured and I appreciate the clean organization.
  • The ablation study is well-designed and highlights the contribution of each component.
  • The robustness analyses in the appendix (SNR sweeps, iEEG coverage, regime duration, dimensionality, etc) are thorough.

Weaknesses

Major

  • It is unclear to me what the specific methodological novelty is. The Kim filter is from Kim and Nelson, elastic net is standard, post-selection refit follows Belloni and Chernozhukov and Meinshausen. The multimodal contribution amounts to stacking H \= [L; C]. Nothing in the formulation beyond the stacking seems to be specific to multimodal data.

  • The E-step is not properly explained in the main text and I feel that one cannot understand it without reading the appendix. The paper names the Kim filter and RTS smoother and states briefly what they output, but that needs to be more motivated.

  • I recognize that the above requires more space, which I think can be freed up by avoiding multiple repetitions and over-explanation in the introduction. For example, I believe the whole paragraph in lines 65-80 can be removed, significantly narrowed, or be moved to the method part. Either way it is hard to understand what is written there before you introduce the problem only after.

  • The paper oscillates between a general framework and an epilepsy-specific tool. The label-switching rule (higher energy = pathological) and the idea that regimes must change "abruptly" may be mainly in epilepsy, as in continuous behavior tasks, neural dynamics may change more smoothly, or, at least, not necessarily abruptly. I think it is important to clarify the intended scope.

  • There is no limitations or future work section, and the conclusion paragraph is a pure summary.

  • The synthetic benchmark uses a single switch point and one broadcasting source, which is a best-case scenario for column-sparse recovery.

  • Latent state recovery (xtx_t), from what I understand, is not evaluated, could the authors explain the motivation for that? I understand there may be rotational ambiguity or sensitivity to initializations, but these can be aligned post hoc to still allow for evaluation.

  • The shared-latent-state formulation has a natural connection to multi-session neural data alignment (e.g., CREIMBO, Mudrik et al. ICLR 2025) and stitching. If your method can indeed be generalized to, as mentioned in line 125, cases where multiple linear sensors observe a shared latent state, then it needs to be discussed. If not, please be more precise as to what are the limitations wrt the variability or overlap in data properties across the sensors.

Minor

  • Figure labels font size is too small.
  • Equation 2 conditions on S_t \= j but does not clarify what happens at regime boundaries.
  • In the M-step, MM mask is re-explained despite already being defined in Section 3, while Bˉ(j)\bar{B}^{(j)} and Aˉ(j)\bar{A}^{(j)}, which are new and central, receive minimal explanation.
  • The ⊙\odot operator (Hadamard product) and the ones vector 1\mathbf{1} should be defined when first used.
  • The notation YtY_t for the stacked observation and yty_t for one component is confusing.
Questions
  1. How does S⁴M³ handle regime transitions in the latent dynamics? I.e. what happens when xt−1x_{t-1} was generated under a different regime i≠ji \neq j?

  2. Why is latent state recovery (xtx_t) not evaluated?

  3. How are λ\lambda, α\alpha, and τΔ\tau_\Delta selected in practice? Are results sensitive to these choices?

  4. How does performance change under more diverse ground-truth structures (e.g., multiple broadcasting sources, bidirectional edges, distributed sparse changes)?

Limitations

No. The paper does not include a limitations section or future work paragraph in the discussion.

Formatting concerns

n/a

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the positive assessment.

Major Weaknesses

1. Methodological novelty and multimodal specificity

The novelty of S4M3S^4M^3 lies in combining anatomically anchored multimodal inference, sparse regime-specific network estimation, and post-selection assessment of cross-regime pathway changes.

Regime-specific anatomical networks as inferential targets. The primary estimands are the directed networks Φj\Phi^j and their contrasts, such as Δ=Φ1−Φ0\Delta=\Phi^1-\Phi^0. As summarized below, S4M3S^4M^3 jointly infers anatomically anchored latent sources, discrete regimes, and sparse regime-specific networks under one likelihood. It therefore identifies which directed pathways change across regimes, estimates the sign and magnitude of those changes, and ranks them after uncertainty and multiplicity adjustment.

Model Latent/partial Multimodal Switching network Network target Contrast assessment
MS-VAR ✗ ✗ ✓ ✗ ✗
Variational SSM ✓ ✗ ✓ ✗ ✗
rSLDS [1] ✓ ✗ ✓ ✗ ✗
Sparse VAR ✗ ✗ ✗ Static ✗
DCM [2] ✓ Sometimes ✗ Static ✗
Two-stage connectivity Indirect Sometimes Usually no Static Post hoc
Stationary EEG-iEEG SSM ✓ ✓ ✗ Static ✗
S4M3S^4M^3 ✓ ✓ ✓ Per regime ✓

Multimodal fusion under complementary partial observation. The multimodal contribution is not merely observation stacking. S4M3S^4M^3 links EEG and iEEG to the same anatomically anchored latent process through distinct modality-specific operators. EEG provides broad but spatially mixed coverage, whereas iEEG provides sparse, locally precise measurements. Their joint use can reduce modality-specific unobservable subspaces, as formalized below. This complementarity has a precise observability consequence.

Proposition 1 (Complementary multimodal observability). For regime jj, let OEjO_E^j and OIjO_I^j denote the observability matrices associated with LL and CC, and define OEIj=[OEj;OIj]O_{EI}^j=[O_E^j;O_I^j]. Then null(OEIj)=null(OEj)∩null(OIj)null(O_{EI}^j)=null(O_E^j)\cap null(O_I^j) and rank(OEIj)≥max⁡(rank(OEj),rank(OIj))rank(O_{EI}^j)\geq\max(rank(O_E^j),rank(O_I^j)). Hence, the joint system is observable whenever the modality-specific null spaces intersect only at 0\mathbf{0}, even if neither modality is individually observable.

The result follows because OEIjv=0O_{EI}^jv=0 if and only if both OEjv=0O_E^jv=0 and OIjv=0O_I^jv=0.

We evaluated this complementarity in a 30-trial coverage-stratified synthetic experiment. Edges were grouped by whether their source and target regions were directly sampled by iEEG (covered) or not (uncovered). For covered-covered edges, the dual model achieved F1=0.838F_1=0.838, versus 0.7190.719 for iEEG-only and 0.1820.182 for EEG-only, with paired gain 0.139[0.090,0.195]0.139 [0.090,0.195]. When only the source or target was covered, iEEG-only achieved F1=0F_1=0, whereas the dual model achieved 0.3670.367 and 0.3630.363, with gains 0.207[0.129,0.290]0.207 [0.129,0.290] and 0.340[0.233,0.451]0.340 [0.233,0.451], respectively. The largest gains occurred when iEEG constrained one endpoint and EEG informed the other, directly matching the complementary-coverage mechanism described by Proposition 1.

Post-selection assessment of pathway changes. Existing switching models generally do not provide pathway-level assessment of cross-regime contrasts because their latent coordinates may not be anatomically anchored, their transition matrices are treated primarily as predictive parameters, or support selection is not separated from uncertainty quantification. Because penalization induces shrinkage bias, direct Wald testing of the penalized coefficients is unsuitable. S4M3S^4M^3 instead combines penalized support selection, unpenalized refitting, fixed-support large-sample Wald assessment, and multiplicity correction, yielding sparse pathway discovery with approximate evidence for regime-dependent change.

2. E-step explanation and manuscript organization

The Kim filter estimates regime-conditioned states and probabilities from the multimodal observations, with moment matching controlling regime-history growth; the RTS smoother then computes the smoothed probabilities and state moments used in the M-step. We will add this explanation, shorten the Introduction, and move technical details to Methods.

3. Intended scope, limitations, future work, and relation to CREIMBO

Scope. S4M3S^4M^3 is intended for regime-dependent directed-network inference from synchronized multimodal measurements of a shared latent process with approximately piecewise-stationary dynamics. Epilepsy is one application; the model does not require any regime to be pathological. The framework may also extend to settings such as EEG-MEG, EEG-LFP, and invasive-noninvasive monitoring, provided the modalities admit linear observation operators into a common latent coordinate system.

Relation to CREIMBO [3]. CREIMBO addresses alignment across non-simultaneous sessions with session-specific neural populations and no shared time axis. In contrast, S4M3S^4M^3 assumes synchronized modalities, a shared anatomical latent space, and known sensor-to-source mappings, and targets regime-specific network contrasts. Extending it to the CREIMBO setting would require session-specific observation operators and explicit cross-session latent alignment.

Future work. Future work will consider uncertain observation operators, asynchronous or multi-rate data, modality-specific latent components, smoothly time-varying dynamics, and validation on larger clinical datasets. We will revise the scope and limitations accordingly.

4. Broader synthetic evaluation and latent-state recovery

We added multi-source, mixed-sign, bidirectional, and recurrent three-regime settings, together with direct latent-state evaluation. The smoothed trajectory is reconstructed as xt^=∑jγt,j^xt,j^\hat{x_t}=\sum_{j}\hat{\gamma_{t,j}}\hat{x_{t,j}}, where γt,j^\hat{\gamma_{t,j}} is the smoothed probability of regime jj and NRMSE is computed against the simulated source trajectory.

Synthetic recovery across two- and three-regime settings. Results are mean$\pm$SD over 50 Monte Carlo trials.

JJ Condition Regime Acc. Edge Sens. Edge Prec. Edge F1F_1 State NRMSE
2 Single source 1.00±0.001.00\pm0.00 0.61±0.060.61\pm0.06 0.53±0.050.53\pm0.05 0.56±0.050.56\pm0.05 0.38±0.040.38\pm0.04
2 Two sources, unidirectional 1.00±0.001.00\pm0.00 0.42±0.040.42\pm0.04 0.30±0.040.30\pm0.04 0.35±0.040.35\pm0.04 0.40±0.070.40\pm0.07
2 Two sources, mixed sign 1.00±0.001.00\pm0.00 0.21±0.040.21\pm0.04 0.25±0.040.25\pm0.04 0.23±0.030.23\pm0.03 0.62±0.040.62\pm0.04
3 Single-hub spread 0.98±0.050.98\pm0.05 0.38±0.050.38\pm0.05 0.46±0.060.46\pm0.06 0.41±0.040.41\pm0.04 0.79±0.230.79\pm0.23
3 Two-hub spread 0.77±0.050.77\pm0.05 0.19±0.030.19\pm0.03 0.17±0.030.17\pm0.03 0.18±0.030.18\pm0.03 0.73±0.200.73\pm0.20
3 Bidirectional spread 0.98±0.040.98\pm0.04 0.30±0.010.30\pm0.01 0.64±0.030.64\pm0.03 0.40±0.010.40\pm0.01 0.89±0.140.89\pm0.14
3 Mixed-sign spread 0.97±0.080.97\pm0.08 0.34±0.070.34\pm0.07 0.42±0.080.42\pm0.08 0.37±0.060.37\pm0.06 0.75±0.280.75\pm0.28

The results show a consistent difficulty gradient. In the two-regime setting, recovery declined as changes became distributed and mixed-sign. In the three-regime setting, single-hub, bidirectional, and mixed-sign conditions retained high regime accuracy, whereas the overlapping two-hub condition was substantially harder. Overall, recovery degraded with increasing overlap and network complexity.

Minor Weaknesses

We will enlarge figure text; clarify that Eq 2 uses the newly active regime jj at time tt, while p(St=j∣St−1=i)p(S_t=j\mid S_{t-1}=i) determines only the switch probability; remove the repeated mask explanation; define Aˉj\bar A^j, Bˉj\bar B^j, ⊙\odot, and 1\mathbf 1 at first use; and standardize observations as ytEy_t^E, ytIy_t^I, and yt=[ytE;ytI]y_t=[y_t^E;y_t^I].

Questions

1. Reply to Q1

If St−1=iS_{t-1}=i and St=jS_t=j, then xt=Φjxt−1+εtjx_t=\Phi^jx_{t-1}+\varepsilon_t^j, with εtj∼N(0,Qj)\varepsilon_t^j\sim\mathcal{N}(0,Q^j). The previous regime affects only the switching probability p(St=j∣St−1=i)p(S_t=j\mid S_{t-1}=i); the state transition at time tt is governed entirely by the newly active regime jj.

2. Reply to Q2

Addressed in the broader synthetic evaluation above. The original experiments focused on regime identification and regime-dependent edge recovery because these are the primary inferential targets of the paper.

3. Reply to Q3

Across the synthetic and real-data analyses, each grid configuration was fit from 10 random initializations, and the representative fit had the highest observed-data likelihood. Synthetic sensitivity results are reported in Appendix H. The nominal (λ,α)(\lambda,\alpha) pair was chosen solely by observed-data likelihood, without using SOZ (Hipp. L). We evaluated λ=(0.0005,0.001,0.002)\lambda = (0.0005,0.001,0.002) and α=(0.90,0.95,0.98)\alpha = (0.90,0.95,0.98). Results were substantially more sensitive to λ\lambda than to α\alpha. At λ=0.0005\lambda=0.0005, 8–10/10 fits were valid, with Hipp. L pathways among the top five in nearly all fits. At λ=0.001\lambda=0.001, validity decreased to 5–6/10, although Hipp. L involvement persisted. At λ=0.002\lambda=0.002, only 00–1/101/10 fits were valid, indicating over-regularization. The fixed threshold τΔ=0.10\tau_\Delta=0.10 is applied only post-fit to select candidates for unpenalized refitting and Wald assessment; it does not affect estimation of states, regimes, or Φj\Phi^j.

4. Reply to Q4

Addressed in the broader synthetic evaluation above.

[1] J. Glaser, M. Whiteway, J. P. Cunningham, L. Paninski, and S. Linderman, “Recurrent switching dynamical systems models for multiple interacting neural populations,” Advances in neural information processing systems, vol. 33, pp. 14 867–14 878, 2020.

[2]Kiebel, Stefan J., Marta I. Garrido, Rosalyn J. Moran, and Karl J. Friston. "Dynamic causal modelling for EEG and MEG." Cognitive neurodynamics 2, no. 2 (2008): 121-136.

[3] Mudrik, Noga, Ryan Ly, Oliver Ruebel, and Adam S. Charles. "Creimbo: Cross-regional ensemble interactions in multi-view brain observations." The International Conference on Learning Representations, 2025.

Reviewer xZKZ · CommentOpenReview ↗

I thank the authors for their detailed rebuttal. That said, I still do not think the paper presents a method novel enough for publication at NeurIPS. Moreover, several of the rebuttal responses to me address points or provide experiments I did not ask for (raised instead by other reviewers) rather than addressing the major limitations I listed (primarily method novelty). My own concerns remain unresolved: the E-step exposition is deferred to a future revision, latent-state recovery appears only in the rebuttal rather than the paper, and Proposition 1, offered as evidence that the contribution exceeds stacking, restates what stacking does, since the joint unobservable subspace is the intersection of the two modality-specific ones. The volume of new results does not settle whether the core contribution is methodological, theoretical, or empirical, which remains my central concern. TBH, I genuinely do think there is an interesting theoretical question latent here, namely when combining the two modalities actually helps recover connections that neither can recover alone, but this is not developed, and the paper does not read as a theory paper.

Authors · CommentOpenReview ↗

We thank the reviewer for stating the remaining concern and noting that parts of our rebuttal addressed other reviewers. We address your central question directly.

S4M3S^4M^3 is primarily a methodological and inferential framework. Its main contribution is a unified approach for estimating sparse, anatomically indexed, regime-specific directed networks from partially observed EEG and iEEG, and assessing which pathways change across regimes.

The novelty does not lie in the Kim filter, elastic net, or post-selection refitting alone, but in the resulting inferential capability: estimating anatomically indexed, regime-specific network contrasts under multimodal partial observation and assessing them with uncertainty and multiplicity control. This is achieved through:

  1. a shared anatomical source space observed by complementary modalities;
  2. sparse directed networks that vary across regimes;
  3. a select–refit–assess procedure for cross-regime pathway changes.

Standard switching state-space models mainly estimate latent states and regime transitions. Sparse VAR models generally assume directly observed nodes. Multimodal state-space models generally do not estimate and statistically assess sparse anatomical pathway changes across regimes. S4M3S^4M^3 addresses this combined problem within one model.

We agree that Proposition 1 should not be presented as a major theoretical contribution. The null-space identity is a general property of stacked linear systems and is not specific to EEG and iEEG. Its intended role is narrower: to clarify when combining the modalities can reduce latent-state ambiguity.

The practical benefit depends not on stacking alone, but on whether the observation operators constrain different directions in the latent source space. The EEG lead-field matrix LL provides broad but spatially mixed measurements, whereas the iEEG observation matrix CC directly measures only a limited set of source locations. Their unobservable subspaces arise from different sensing mechanisms and need not coincide. When complementary, the joint observations can constrain latent directions that remain ambiguous under either modality alone. We will present Proposition 1 as motivation for the multimodal formulation, rather than as the central theoretical contribution.

The coverage-stratified experiment addresses the substantive question raised by the reviewer: when does combining EEG and iEEG improve pathway recovery? The largest gains occurred when iEEG directly constrained one endpoint of a pathway and EEG informed the other. This is consistent with the observation operators providing complementary information. It gives empirical evidence that complementary coverage improves directed-edge recovery, although it is not a complete theory of multimodal support recovery.

We also agree that the E-step exposition should have been clearer in the submitted paper. The appendix already contains the complete E-step algorithm and derivation; the main text does not sufficiently explain how the Kim filter estimates regime-conditioned states and probabilities, how moment matching controls regime-history growth, and how the RTS smoother provides the moments used in the M-step. We will add this explanation.

Latent-state recovery was not emphasized originally, since our primary inferential targets are regime identification and pathway changes, not latent-trajectory reconstruction. We agree it is a useful supporting evaluation and have added state NRMSE results for the revised manuscript.

The broader synthetic experiments were not intended to establish theoretical novelty. They directly address the reviewer’s concern that the initial benchmark used one broadcasting source and one switch point. The added multi-source, bidirectional, mixed-sign, distributed, repeated-transition, and three-regime settings test whether the framework remains effective beyond that favorable case.

We will therefore state the contribution hierarchy more clearly:

  • Primary contribution: a methodological and inferential framework for sparse regime-dependent anatomical network estimation under multimodal partial observation;
  • Supporting analysis: an observability characterization that motivates complementary measurements;
  • Empirical validation: broader synthetic experiments, coverage-specific analysis, and real-data comparisons;
  • Future direction: theory establishing when multimodal fusion enables recovery of connections that neither modality can recover alone.

We agree that this is a deeper theoretical question than Proposition 1 currently answers, and we do not claim that the present paper resolves it. Our claim is narrower: S4M3S^4M^3 introduces and validates a unified framework for estimating and assessing regime-dependent anatomical pathway changes from synchronized multimodal observations. We view the reviewer’s question as a natural theoretical extension of this work, rather than as the contribution claimed here.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…