Breaking Noise Shortcuts in Self-Supervised Learning via Noise-Aligned View Generation
Oankar R. Patil, May Dongmei Wang
NeurIPS 2026
TL;DR. SEANA improves self-supervised learning from noisy images by generating training views with independent noise, helping models focus on meaningful content without clean reference images, model changes, or extra processing at inference.
Abstract. Self-supervised learning (SSL) is increasingly applied to scientific imaging domains, such as microscopy, where labels are scarce but noisy data is abundant. These domains exhibit significant signal-dependent noise, which can create a representational shortcut: since both augmented views derive from the same noisy image, the encoder can boost view agreement by also encoding noise patterns rather than semantic content. To enable noise-robust representation learning without knowledge of underlying noise models, we introduce Self-Aligned Noise Augmentation (SEANA), a drop-in module that generates noise-aware SSL views. SEANA learns an invertible variance-stabilizing transform (VST) from noisy data, then estimates the clean signal and resamples independent noise in learned VST space, requiring no clean targets, no dataset-specific denoiser training or use at inference, and no changes to the SSL objective or encoder. On CIFAR-10 and ImageNet-100 under synthetic Gaussian, Poisson–Gaussian, and multiplicative noise, SEANA improves clean-test linear-probe accuracy across contrastive/non-contrastive SSL methods, indicating higher-quality representations. On real fluorescence imaging, SEANA improves Jurkat cell-cycle stage classification by up to 28.6pp over standard SSL and 27.5pp over denoiser-preprocessed baselines. In all settings, SEANA outperforms the denoiser-preprocessed SSL pipelines, demonstrating that learned VST-space noise-aligned resampling yields more robust representations than denoising alone. Code can be found here: https://github.com/opatil31/SEANA
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:44 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The paper introduces a drop-in view-generation module, for noise-robust representation learning in joint-embedding SSL, and shows improvements across different SSL methods and noise families, including synthetic benchmarks and real fluorescence microscopy dataset.
The strengths appreciated by the reviewers include addressing important problem relevant to scientific imaging, clear motivation, reasonable design to use a learned variance-stabilizing transform, flexible plug-in with existing SSL methods, comprehensive experiments and good performance gain.
Before rebuttal, reviewers also raised concerns regarding the need for direct evidence supporting the central claim that baseline representations encode noise and that the proposed method reduces it, isolation of the learned transform's contribution from generic noise resampling, comparison against stronger and more recent denoising baselines, broader real data evaluation across additional noise conditions, clarification of the sensitivity parameter selection and the role of the frozen denoiser, more careful scoping of theoretical claims, and improvements to presentation including the augmentation pipeline description. The author has provided a very detailed and thorough response during the rebuttal, which was well received by all the reviewers. Reviewers found that the additional experiments, including stronger denoising baselines, representation invariance analysis, and expanded evaluation across SSL methods and datasets, substantially addressed the concern All reviewers either raised their scores following the rebuttal or maintained a positive position. Without major concerns remaining, I recommend Accept.
Final justification
Please see meta review.
- Final justification
- Please see meta review.
Read meta-review
Meta-review
The paper introduces a drop-in view-generation module, for noise-robust representation learning in joint-embedding SSL, and shows improvements across different SSL methods and noise families, including synthetic benchmarks and real fluorescence microscopy dataset.
The strengths appreciated by the reviewers include addressing important problem relevant to scientific imaging, clear motivation, reasonable design to use a learned variance-stabilizing transform, flexible plug-in with existing SSL methods, comprehensive experiments and good performance gain.
Before rebuttal, reviewers also raised concerns regarding the need for direct evidence supporting the central claim that baseline representations encode noise and that the proposed method reduces it, isolation of the learned transform's contribution from generic noise resampling, comparison against stronger and more recent denoising baselines, broader real data evaluation across additional noise conditions, clarification of the sensitivity parameter selection and the role of the frozen denoiser, more careful scoping of theoretical claims, and improvements to presentation including the augmentation pipeline description. The author has provided a very detailed and thorough response during the rebuttal, which was well received by all the reviewers. Reviewers found that the additional experiments, including stronger denoising baselines, representation invariance analysis, and expanded evaluation across SSL methods and datasets, substantially addressed the concern All reviewers either raised their scores following the rebuttal or maintained a positive position. Without major concerns remaining, I recommend Accept.
6 comments
Rebuttal Part 2
Concern 2: Isolate the contribution of the learned transform, ideally through oracle or analytic comparisons that separate the proposed mechanism from generic noise resampling.
We compare SEANA to oracle noise-aligned augmentation, analytic VST plus resampling, and raw-domain noise resampling when the true noise model is known across all noise regimes. Each low and high noise regime below is the same as in the original synthetic noisy CIFAR-10 experiment:
Table 1 (Summary):
| Rank | Approach | Required External Knowledge | Mean Accuracy (%) | Mean Gain vs. Ref (+pp) | Median Gain (+pp) | Gain Range [Min, Max] |
|---|---|---|---|---|---|---|
| — | Oracle (Upper Bound) | True clean image + exact noise model | 59.37% | +16.69 | +16.50 | [+7.0, +27.0] |
| 1 | SEANA | Nothing | 57.68% | +15.01 | +14.15 | [+5.9, +26.6] |
| 2 | Analytical VST + Resample | Noise Family | 54.86% | +12.18 | +12.85 | [+1.8, +22.8] |
| 3 | NSP + Resample | Exact noise model | 53.24% | +10.56 | +11.55 | [-2.0, +19.8] |
| 4 | NSP | Nothing | 46.35% | +3.67 | +2.25 | [-1.9, +16.4] |
| 5 | N2N + Resample | Exact noise model | 45.68% | +3.00 | +4.65 | [-8.6, +14.0] |
| 6 | N2N | Nothing | 43.49% | +0.82 | +0.20 | [-4.6, +7.0] |
| — | Baseline (Ref) | - | 42.68% | 0.00 | 0.00 | [0.0, 0.0] |
Table 2 (Full):
| Noise Cond. | SSL | N2N | NSP | N2N + Resample | NSP + Resample | Analytical VST + Resample | SEANA | Oracle | Baseline (Ref) |
|---|---|---|---|---|---|---|---|---|---|
| Gauss_Low | BYOL | 51.8 | 54.4 | 57.6 | 57.4 | 60.7 | 60.8 | 61.4 | 52.3 |
| SimCLR | 59.8 | 58.6 | 62.3 | 58.1 | 61.9 | 66.0 | 67.2 | 60.1 | |
| VICReg | 64.8 | 61.7 | 67.3 | 64.6 | 69.3 | 69.4 | 69.5 | 62.5 | |
| Gauss_High | BYOL | 22.9 | 25.8 | 26.9 | 40.3 | 41.0 | 41.9 | 49.3 | 27.5 |
| SimCLR | 28.1 | 29.2 | 36.1 | 40.5 | 42.5 | 42.2 | 49.1 | 22.1 | |
| VICReg | 30.1 | 28.9 | 38.3 | 43.8 | 43.4 | 47.4 | 50.1 | 30.8 | |
| PG_Low | BYOL | 48.0 | 48.9 | 52.9 | 56.8 | 59.6 | 59.9 | 59.9 | 46.5 |
| SimCLR | 53.5 | 57.4 | 58.7 | 56.9 | 61.8 | 65.0 | 64.8 | 51.1 | |
| VICReg | 56.9 | 60.0 | 64.6 | 64.3 | 68.7 | 69.1 | 69.7 | 58.7 | |
| PG_High | BYOL | 27.5 | 35.7 | 23.8 | 45.7 | 44.5 | 47.8 | 51.6 | 29.7 |
| SimCLR | 29.2 | 37.6 | 28.6 | 47.0 | 41.1 | 50.5 | 52.3 | 27.2 | |
| VICReg | 31.1 | 33.0 | 30.3 | 51.8 | 53.0 | 54.7 | 54.7 | 32.1 | |
| Speckle_Low | BYOL | 51.3 | 51.2 | 56.6 | 57.7 | 59.0 | 61.5 | 61.6 | 52.1 |
| SimCLR | 58.8 | 59.8 | 63.1 | 58.8 | 59.5 | 67.0 | 67.4 | 55.5 | |
| VICReg | 61.0 | 63.2 | 68.8 | 66.6 | 67.3 | 71.4 | 71.7 | 63.7 | |
| Speckle_High | BYOL | 34.4 | 36.1 | 29.2 | 46.8 | 46.8 | 50.1 | 54.0 | 30.3 |
| SimCLR | 35.1 | 44.5 | 27.8 | 47.9 | 46.7 | 54.7 | 54.5 | 28.1 | |
| VICReg | 38.6 | 48.3 | 29.3 | 53.3 | 60.7 | 58.9 | 59.8 | 37.9 |
Rebuttal Part 3
Concern 3: Strengthen the baseline set with stronger and more recent denoising alternatives.
We leverage Next-Scale Prediction (NSP) [1], a SSL Denoising paradigm recently introduced in CVPR '26 (June 2026) that greatly outperformed Neighbor2Neighbor (N2N) which was used in our paper, as well as outperforming other recent SSL denoisers. As an example, NSP achieved a PSNR of 37.02 and an SSIM of 0.8865 on the SIDD Dataset in contrast to Neighbor2Neighbor which sat at PSNR of 28.00 and SSIM of 0.5890. NSP is, to our knowledge, the current SOTA SSL Denoiser.
On CIFAR-10's synthetic high noisy data regimes, we compared N2N-denoising alone, NSP-alone, DRUNet-alone (SEANA used frozen DRUNet as gaussian denoiser for its main paper experiments), and SEANA's learned VST + DRUNet in terms of PSNR to evaluate which produces the cleanest estimate:
Table 3 (PSNR of Denoisers on CIFAR-10 Noisy)
| Noise Cond. | N2N | NSP | DRUNet | DRUNet + VST (SEANA) |
|---|---|---|---|---|
| Gauss_High | 13.46 | 17.55 | 16.90 | 17.96 |
| PG_High | 15.00 | 18.44 | 15.97 | 19.96 |
| Speckle_High | 16.00 | 18.76 | 13.56 | 20.13 |
Further, we find that in synthetic noisy CIFAR-10, SEANA is able to outperform both:
- NSP denoising alone as well
- NSP + Resampling with the True/Known Noise Model
- We note that in practical reality, it would be difficult to resample with the true noise model, so this represents an upper bound of generic noise resampling with NSP Table 4:
| Noise Cond. | SSL | NSP | NSP + Resample | SEANA | Baseline (Ref) |
|---|---|---|---|---|---|
| Gauss_Low | BYOL | 54.4 | 57.4 | 60.8 | 52.3 |
| SimCLR | 58.6 | 58.1 | 66.0 | 60.1 | |
| VICReg | 61.7 | 64.6 | 69.4 | 62.5 | |
| Gauss_High | BYOL | 25.8 | 40.3 | 41.9 | 27.5 |
| SimCLR | 29.2 | 40.5 | 42.2 | 22.1 | |
| VICReg | 28.9 | 43.8 | 47.4 | 30.8 | |
| PG_Low | BYOL | 48.9 | 56.8 | 59.9 | 46.5 |
| SimCLR | 57.4 | 56.9 | 65.0 | 51.1 | |
| VICReg | 60.0 | 64.3 | 69.1 | 58.7 | |
| PG_High | BYOL | 35.7 | 45.7 | 47.8 | 29.7 |
| SimCLR | 37.6 | 47.0 | 50.5 | 27.2 | |
| VICReg | 33.0 | 51.8 | 54.7 | 32.1 | |
| Speckle_Low | BYOL | 51.2 | 57.7 | 61.5 | 52.1 |
| SimCLR | 59.8 | 58.8 | 67.0 | 55.5 | |
| VICReg | 63.2 | 66.6 | 71.4 | 63.7 | |
| Speckle_High | BYOL | 36.1 | 46.8 | 50.1 | 30.3 |
| SimCLR | 44.5 | 47.9 | 54.7 | 28.1 | |
| VICReg | 48.3 | 53.3 | 58.9 | 37.9 |
BBBC048 (Real Fluorescence Imaging Dataset) - Extended Evaluation:
We also then evaluate NSP + SSL in BBBC048, for the following SSL methods, across 3 seeds on Linear Probe Top-1 Accuracy:
- SimCLR, VICReg, BYOL, MoCoV2 [2], LeJEPA [3]
Table 5:
| SSL Method | Baseline | N2N + SSL | NSP + SSL | SEANA |
|---|---|---|---|---|
| BYOL | 63.4 +- 3.4 | 67.3 +- 2.0 | 67.9 +- 2.3 | 75.7 +- 0.1 |
| SimCLR | 46.9 +- 0.3 | 48.2 +- 0.6 | 46.6 +- 0.6 | 75.5 +- 0.1 |
| VICReg | 46.8 +- 0.2 | 47.4 +- 0.8 | 48.6 +- 0.3 | 74.4 +- 0.2 |
| LeJEPA | 47.5 +- 0.4 | 49.4 +- 0.3 | 49.3 +- 0.4 | 74.4 +- 0.3 |
| MoCoV2 | 71.5 +- 1.9 | 73.3 +- 0.1 | 73.9 +- 0.1 | 75.1 +- 0.6 |
SEANA Ablation:
| SSL Method | Baseline | VST-Only | Resampling-Only | SEANA (Full) |
|---|---|---|---|---|
| BYOL | 63.4 +- 3.4 | 59.6 +- 0.1 | 46.5 +- 0.2 | 75.7 +- 0.1 |
| SimCLR | 46.9 +- 0.3 | 47.3 +- 0.5 | 74.2 +- 0.0 | 75.5 +- 0.1 |
| VICReg | 46.8 +- 0.2 | 46.1 +- 1.0 | 73.3 +- 0.1 | 74.4 +- 0.2 |
| LeJEPA | 47.5 +- 0.4 | 47.6 +- 0.3 | 73.2 +- 0.1 | 74.4 +- 0.3 |
| MoCoV2 | 71.5 +- 1.9 | 66.75 +- 0.1 | 68.1 +- 1.1 | 75.1 +- 0.6 |
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper introduces self-aligned noise augmentation (SEANA), which addresses the short-cut learning for signal-dependent noises in joint-embedding self-supervised learning. SEANA learns an invertible variance-stabilizing transform (VST) from noisy data via an invertible spline, then estimates the clean signal via an off-the-shelf decoder and resamples independent noise in learned VST space. After inverse VST, the two augmented images are then fed to train the joint-embedding SSL model. The main contributions are the proposal of the SEANA module and their consistent improvements across various noise types and model families.
Strengths and weaknesses
Strengths:
- The experiments are comprehensive, covering different joint-embedding models (i.e., BYOL, SimCLR, and VICReg) and both synthetic and real noisy datasets.
- The results are strong, significantly surpassing the baseline.
- The designs are well-motivated by prior theories..
- SEANA is paremeter-efficient, requiring only 130 parameters for the variance-stablizing transform....
Weaknesses:
- The ablation studies show that resampling-only method also significantly improve over the baseline (except BYOL collapses), which raises the possibility that simply making the two views have independent noise realizations is enough. This to some extent weakens the necessity of "VST" claim.
- Current setting is still relatively small-scale. It would be better to demonstrate the effectiveness on larger scale, e.g., ImageNet-1k with DINOv2
- "(Low) Shot" is repeated two times in table 3
Questions
- The paper uses N2N (neighbor2neighbor, 2021) as the denoising baseline, which can be a bit outdated. I am interested whether using a more recent SOTA SSL denoiser network could be a stronger baseline?
- On line 236-237, it trains N2N then SSL during training stage. Are the denoised images used for test-time/downtream evaluation? Can you expand why (N2N + SSL) repetitively degrade the linear probe performance (line 249)?
- What is the advantage of the VST method over fitting a conditional noise model and resampling from that model?
- As the learning objective for VST is indirect , how do we know/gaurantee the learned transform is actually a VST?
Limitations
- The N2N baseline can be relatively weak compared to recent SSL denoisers.
Final justification
My issues such as using a stronger denoising baseline and questions about learning objectives are mostly resolved during the rebuttal.
Based on the experiments and justifications, I agree that SEANA is a novel and effective methods for SSL for noisy images.
Formatting concerns
N/A
5 comments
Rebuttal Part 1
Thank you for your valuable feedback and questions. We are happy to hear your appreciation regarding our experimental coverage being overall comprehensive, the strength of our results, our method being well motivated by previous theoretical work in SSL, and the parameter efficiency of SEANA.
Q1: The paper uses N2N (neighbor2neighbor, 2021) as the denoising baseline, which can be a bit outdated. I am interested whether using a more recent SOTA SSL denoiser network could be a stronger baseline?
In the below responses, we leverage Next-Scale Prediction (NSP) [1], a SSL Denoising paradigm recently introduced in CVPR '26 (June 2026) that greatly outperformed Neighbor2Neighbor (N2N) which was used in our paper, as well as outperforming other recent SSL denoisers. As an example, NSP achieved a PSNR of 37.02 and an SSIM of 0.8865 on the SIDD Dataset in contrast to Neighbor2Neighbor which sat at PSNR of 28.00 and SSIM of 0.5890. NSP is, to our knowledge, the current SOTA SSL Denoiser.
On CIFAR-10's synthetic high noisy data regimes, we compared N2N-denoising alone, NSP-alone, DRUNet-alone (SEANA used frozen DRUNet as gaussian denoiser for its main paper experiments), and SEANA's learned VST + DRUNet in terms of PSNR to evaluate which produces the cleanest estimate:
Table 1 (PSNR of Denoisers on CIFAR-10 Noisy)
| Noise Cond. | N2N | NSP | DRUNet | DRUNet + VST (SEANA) |
|---|---|---|---|---|
| Gauss_High | 13.46 | 17.55 | 16.90 | 17.96 |
| PG_High | 15.00 | 18.44 | 15.97 | 19.96 |
| Speckle_High | 16.00 | 18.76 | 13.56 | 20.13 |
Further, we find that SEANA is able to outperform in synthetic noisy CIFAR-10, both:
- NSP denoising alone as well
- NSP + Resampling with the True/Known Noise Model
- We note that in practical reality, it would be difficult to resample with the true noise model, so this represents an upper bound of generic noise resampling with NSP
Table 2:
*Note: Oracle = Oracle Noise-Aligned Augmentation: We take the original clean data + Resampling with the True/Known Noise Model, represents an upper ceiling. Additionally, the below low and high noise regimes are the same as those used in the main paper's synthetic noisy CIFAR-10 data regimes.
| Noise Cond. | SSL | N2N | N2N + Resample | NSP | NSP + Resample | SEANA | Oracle | Baseline (Ref) |
|---|---|---|---|---|---|---|---|---|
| Gauss_Low | BYOL | 51.8 | 57.6 | 54.4 | 57.4 | 60.8 | 61.4 | 52.3 |
| SimCLR | 59.8 | 62.3 | 58.6 | 58.1 | 66.0 | 67.2 | 60.1 | |
| VICReg | 64.8 | 67.3 | 61.7 | 64.6 | 69.4 | 69.5 | 62.5 | |
| Gauss_High | BYOL | 22.9 | 26.9 | 25.8 | 40.3 | 41.9 | 49.3 | 27.5 |
| SimCLR | 28.1 | 36.1 | 29.2 | 40.5 | 42.2 | 49.1 | 22.1 | |
| VICReg | 30.1 | 38.3 | 28.9 | 43.8 | 47.4 | 50.1 | 30.8 | |
| PG_Low | BYOL | 48.0 | 52.9 | 48.9 | 56.8 | 59.9 | 59.9 | 46.5 |
| SimCLR | 53.5 | 58.7 | 57.4 | 56.9 | 65.0 | 64.8 | 51.1 | |
| VICReg | 56.9 | 64.6 | 60.0 | 64.3 | 69.1 | 69.7 | 58.7 | |
| PG_High | BYOL | 27.5 | 23.8 | 35.7 | 45.7 | 47.8 | 51.6 | 29.7 |
| SimCLR | 29.2 | 28.6 | 37.6 | 47.0 | 50.5 | 52.3 | 27.2 | |
| VICReg | 31.1 | 30.3 | 33.0 | 51.8 | 54.7 | 54.7 | 32.1 | |
| Speckle_Low | BYOL | 51.3 | 56.6 | 51.2 | 57.7 | 61.5 | 61.6 | 52.1 |
| SimCLR | 58.8 | 63.1 | 59.8 | 58.8 | 67.0 | 67.4 | 55.5 | |
| VICReg | 61.0 | 68.8 | 63.2 | 66.6 | 71.4 | 71.7 | 63.7 | |
| Speckle_High | BYOL | 34.4 | 29.2 | 36.1 | 46.8 | 50.1 | 54.0 | 30.3 |
| SimCLR | 35.1 | 27.8 | 44.5 | 47.9 | 54.7 | 54.5 | 28.1 | |
| VICReg | 38.6 | 29.3 | 48.3 | 53.3 | 58.9 | 59.8 | 37.9 |
Q1. Continued Below
Rebuttal Part 2
Q1. Continued
We also then evaluate NSP + SSL in BBBC048, for the following SSL methods, across 3 seeds on Linear Probe Top-1 Accuracy:
- SimCLR, VICReg, BYOL, MoCoV2 [2], LeJEPA [3]
Table 3:
| SSL Method | Baseline | NSP + SSL | SEANA |
|---|---|---|---|
| BYOL | 63.4 +- 3.4 | 67.9 +- 2.3 | 75.7 +- 0.1 |
| SimCLR | 46.9 +- 0.3 | 46.6 +- 0.6 | 75.5 +- 0.1 |
| VICReg | 46.8 +- 0.2 | 48.6 +- 0.3 | 74.4 +- 0.2 |
| LeJEPA | 47.5 +- 0.4 | 49.3 +- 0.4 | 74.4 +- 0.3 |
| MoCoV2 | 71.5 +- 1.9 | 73.9 +- 0.1 | 75.1 +- 0.6 |
W1: The ablation studies show that resampling-only method also significantly improve over the baseline (except BYOL collapses), which raises the possibility that simply making the two views have independent noise realizations is enough. This to some extent weakens the necessity of "VST" claim.
Table 2 shows that Oracle Noise-Aligned Augmentation is the clear ceiling and highlights that an ideal method would produce a completely clean version of the data and resample with the exact true/known noise model.
Then, in Table 1, we see that DRUNet by itself is actually a weaker denoiser than NSP. However, by leveraging SEANA's learned VST, DRUNet is better able to adapt to the noise characteristics in each high noise data regime, allowing for SEANA to produce cleaner estimates (than even NSP) to perform its resampling step with. This showcases one necessity of the VST.
Table 2 also highlights that even when given the true/known noise model to perform resampling with for NSP, as an upper bound of generic noise resampling, SEANA still outperforms such independent noise realizations. This is in spite of the fact that SEANA is only leveraging simple gaussian resampling in the learned VST space.
As such, we see that the learned VST allows for SEANA to leverage frozen denoisers to produce cleaner estimates as well as leverage the inverse of the learned VST for approximating simple gaussian resampling as independent noise realizations from the true/known noise model.
Finally, Table 6 below highlights that momentum-based SSL methods like BYOL and MoCoV2 suffer from if we were to do generic resampling only and are more fragile to it, while non-momentum SSL is robust to it.
Table 6 - BBBC048 Ablation Study of SEANA:
| SSL Method | Baseline | VST-Only | Resampling-Only | SEANA (Full) |
|---|---|---|---|---|
| BYOL | 63.4 +- 3.4 | 59.6 +- 0.1 | 46.5 +- 0.2 | 75.7 +- 0.1 |
| SimCLR | 46.9 +- 0.3 | 47.3 +- 0.5 | 74.2 +- 0.0 | 75.5 +- 0.1 |
| VICReg | 46.8 +- 0.2 | 46.1 +- 1.0 | 73.3 +- 0.1 | 74.4 +- 0.2 |
| LeJEPA | 47.5 +- 0.4 | 47.6 +- 0.3 | 73.23 +- 0.1 | 74.4 +- 0.3 |
| MoCoV2 | 71.5 +- 1.9 | 66.75 +- 0.1 | 68.1 +- 1.1 | 75.1 +- 0.6 |
Rebuttal Part 3
Q2: On line 236-237, it trains N2N then SSL during training stage. Are the denoised images used for test-time/downtream evaluation? Can you expand why (N2N + SSL) repetitively degrade the linear probe performance (line 249)?
Yes, for N2N + SSL, the denoised images are used for test-time/downstream evaluation. We see that N2N + SSL repetitively degrades the linear probe performance because N2N does not produce a very clean estimate. NSP + SSL tends to help the improve the linear probe performance in contrast to N2N and Baselines (further shown above on BBBC048 in Table 3, as well as in Table 2 above), but not to the degree of SEANA.
We also try to directly measure how baseline representations encode noise and how denoising and SEANA directly influence these representations. We show the following in the main paper's synthetic noisy CIFAR-10 data scenarios:
For each clean test image, we draw k = 8 independent noise realizations, embed all of them with the frozen backbone, and run a one-way ANOVA on the embeddings grouped by clean-image identity:
- S_W = mean within-image variance (the 8 embeddings of the same clean image spread apart only because the noise differs), i.e noise-driven variance
- S_B = between-image variance (different images) - i.e content
Our primary metric is then:
Where ICC is the standard one-way intraclass correlation coefficient (equivalently
1 − ICC = 1 − η², the complement of the ANOVA effect size).
- Lower
1 − ICC= the representation barely moves when only the noise changes = more noise-invariant. - We also clarify that all measurements are forward passes on frozen backbones
Additional Metrics:
- Content re-ID: nearest-neighbor retrieval of the same clean image across two independent noise draws.
- High = content survives the noise.
- Effective rank (
eff_rank): participation ratio of the embedding covariance = effective dimensionality.
- Content re-ID: nearest-neighbor retrieval of the same clean image across two independent noise draws.
Table 4:
| Noise Cond. | Baseline (1- ICC) | SEANA (1 - ICC) | Reduction |
|---|---|---|---|
| Gauss_Low | 0.0212 | 0.0126 | -40% |
| Gauss_High | 0.1147 | 0.0630 | -45% |
| PG_Low | 0.0262 | 0.0195 | -26% |
| PG_High | 0.0792 | 0.0509 | -36% |
| Speckle_Low | 0.0203 | 0.0156 | -23% |
| Speckle_High | 0.0513 | 0.0360 | -30% |
At high noise ~5–11% of the baseline embedding's variance is pure noise, SEANA cuts that fraction by a third to a half.
Why denoising-only fails from this angle:
Table 5 (Gauss_High Noise Scenario in synthetic noisy CIFAR-10 Experiment):
| Approach | 1 - ICC | S_W (Noise) | S_B (Content) | eff_rank | content re-ID |
|---|---|---|---|---|---|
| Baseline | 0.115 | 144.5 | 1049 | 31.2 | 0.786 |
| NSP | 0.206 | 42.6 | 175 | 7.1 | 0.247 |
| SEANA | 0.063 | 84.4 | 1235 | 24.5 | 0.905 |
- NSP removes the most absolute noise (S_W 42.6 vs 144.5) yet has the worst
1 − ICC, because its content variance collapses 6× (S_B 1049→175) and dimensionality crashes (eff_rank 31→7). - Denoising alone strips the variance the SSL objective needs to stay non-degenerate.
- SEANA restores it (SEANA S_B 1235, eff_rank 24.5, content re-ID 0.79→0.91).
Q3: What is the advantage of the VST method over fitting a conditional noise model and resampling from that model?
We see that the learned VST is not just useful for approximating independent noise realizations from the true/known noise model, but that it is also capable of bringing frozen gaussian denoiser's clean signal estimates higher than SOTA SSL denoisers such as NSP (Table 1).
Furthermore, Table 2 highlights that even when given the ideal of a true/known noise model (which is what fitting a conditional noise model would try to approximate) to resample from, SEANA's inverse of learned VST is capable of allowing simple gaussian resampling to outperform resampling using true/known noise model paired with a SOTA SSL Denoiser (ex NSP).
- Rating
- 5/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper studies self-supervised learning for image data with signal-dependent noise, especially in scientific imaging domains such as fluorescence microscopy. The authors argue that standard joint-embedding SSL can learn a shortcut because both augmented views are generated from the same noisy observation. As a result, the encoder may improve view agreement by encoding shared noise patterns rather than semantic content.
To address this, the authors propose SEANA, a drop-in view generation module for SSL. SEANA learns an invertible variance-stabilizing transform from noisy training data, uses a frozen Gaussian denoiser to estimate the clean signal in the transformed space, resamples independent Gaussian noise in that space, and then maps the result back to image space. The SSL objective and encoder architecture remain unchanged.
The authors evaluate SEANA on synthetic noisy versions of CIFAR-10 and ImageNet-100 using BYOL, SimCLR, and VICReg, as well as on a real fluorescence microscopy dataset for Jurkat cell-cycle classification. The results show consistent improvements over standard noisy SSL and denoiser-preprocessed SSL baselines. The paper also includes ablations showing that both the learned VST and noise resampling are important for the method.
Strengths and weaknesses
The paper addresses an important and practical problem: self-supervised representation learning when the input data contains substantial signal-dependent noise. This setting is especially relevant for scientific imaging, where labels are often scarce and noisy data is abundant. The motivation is clear, and the proposed method is appealing because it can be inserted into existing joint-embedding SSL pipelines without modifying the encoder, objective, or downstream inference procedure.
A major strength of the paper is that the method is simple and modular. Learning a variance-stabilizing transform and then resampling noise in the transformed space is a natural way to make signal-dependent noise closer to the homoscedastic setting assumed by existing noise-alignment arguments. The paper explains this intuition clearly, and Figure 1 gives a useful overview of the difference between standard SSL and SEANA.
The empirical evaluation is also reasonably strong. The authors test SEANA across three SSL methods, three noise families, two synthetic benchmarks, and a real fluorescence microscopy dataset. The reported improvements are consistent across the synthetic experiments, and the gains on the real microscopy dataset are especially large. The ablation study is useful because it shows that VST-only and resampling-only variants are not sufficient in all cases, and that raw-domain resampling can collapse BYOL.
However, I have several concerns.
-
The central noise-shortcut argument is plausible, but the paper does not directly measure whether the learned representations encode noise. Most of the evidence is downstream accuracy improvement and residual analysis. A stronger paper would include direct evidence that baseline SSL representations contain noise information and that SEANA reduces this. For example, the authors could probe representations for recoverability of noise residuals, evaluate representation invariance under independent noisy observations of the same clean image, or directly measure agreement between representations generated from independently resampled noise.
-
The theoretical motivation comes from an additive linear-Gaussian noise-alignment setting, but the method is applied to signal-dependent, nonlinear, clipped, multiplicative, Poisson-Gaussian, and real microscopy noise. The intuition is reasonable, but the paper should be more careful about the scope of the theoretical claim. The current presentation sometimes suggests that satisfying alignment in learned VST space follows directly, but this depends on the quality of the learned transform and denoiser.
-
The baseline set could be stronger. Since the synthetic experiments use known noise models, the authors could compare against oracle noise-aligned augmentation or analytic VST plus resampling. These baselines would help isolate whether the gains come specifically from the learned VST, from noise resampling more generally, or from weaknesses of the denoising baseline. The Neighbor2Neighbor comparison is useful, but it is not enough to fully establish that SEANA is the best or most principled way to generate noise-aligned views.
-
The real-data evaluation is limited to one microscopy dataset and uses a stratified random 80/20 split. For microscopy data, random cell-level splits can sometimes overestimate generalization if train and test images share acquisition conditions, fields of view, plates, or batches. A held-out plate, batch, acquisition, or experiment split would make the real-data result more convincing. Additional real scientific imaging datasets with different noise profiles would also strengthen the significance of the work.
-
The resampling strength parameter appears important. The appendix shows that performance is sensitive to sigma_vst, especially for BYOL, which can collapse when the resampling strength is too large. The paper states that sigma_vst can be tuned on a held-out split or estimated from residuals, but it is not fully clear how this was selected in the main experiments without using downstream labels. A fully label-free selection rule would make the method easier to trust and apply.
-
The method depends on a frozen off-the-shelf denoiser. The paper includes a denoiser-family ablation, which is helpful, but the role of the denoiser should be clarified. In particular, it was not fully clear whether the denoiser itself is blind-spot, or whether a standard Gaussian denoiser is used inside a blind-spot calibration procedure. The authors should also discuss possible failure cases when the denoiser is poorly matched to the image domain or when the signal-to-noise ratio is very low.
Questions
-
Can the authors provide a direct measurement showing that baseline SSL representations encode shared noise patterns and that SEANA reduces this? For example, can noise residuals be predicted from the learned representations?
-
In the synthetic experiments, how does SEANA compare to oracle noise-aligned augmentation, analytic VST plus resampling, and raw-domain noise resampling when the true noise model is known?
-
How is sigma_vst selected in the main experiments without using downstream labels or test-set feedback? Can the authors provide a fully unsupervised selection rule?
-
Can the authors evaluate BBBC048 using a more stringent held-out split, such as by plate, batch, acquisition condition, or field of view?
-
Can the authors clarify the role of the frozen denoiser, including which checkpoints are used, whether the denoiser itself is blind-spot, and how sensitive SEANA is to denoiser domain mismatch?
Limitations
No. The paper does include a useful limitations paragraph discussing pixelwise independent noise, the need to tune sigma_vst, and dependence on the frozen denoiser. However, the limitations section should also discuss the limited real-world evaluation, the risk that random cell-level microscopy splits may overestimate generalization, the need for a label-free hyperparameter-selection procedure, and possible failures under denoiser domain mismatch or very low-SNR data.
Final justification
Thank you for the detailed rebuttal and additional experiments. The response has addressed most of my concerns.
In particular, the new representation-invariance analysis provides direct evidence for the proposed noise-shortcut mechanism. The comparisons against oracle augmentation, analytical VST, and the stronger NSP denoiser also better isolate the contribution of SEANA. The expanded evaluation across additional SSL methods and the Fetal Planes DB dataset further strengthens the empirical support and generality of the method.
I therefore update my rating from 4: Borderline Accept to 5: Accept, while maintaining my confidence score of 3.
Formatting concerns
Yes. The paper states that code is not provided during the initial review phase, although the authors commit to release it upon acceptance.
6 comments
Rebuttal Part 1
Thank your for your detailed and thorough feedback that help improve the paper. We are happy to hear that you appreciated the importance of studying this problem for scientific imaging, the simplicity/modularity of our method design, the flexibility of it easily integrating into various joint-embedding SSL pipelines, our initial empirical evaluation/experimental coverage being reasonably strong, and our ablation study providing relevant insights into SEANA's mechanisms.
Q1. Can the authors provide a direct measurement showing that baseline SSL representations encode shared noise patterns and that SEANA reduces this? For example, can noise residuals be predicted from the learned representations?
To directly measure measure whether baseline representations encode noise and that SEANA, the proposed method, reduces it, we show the following in the main paper's synthetic noisy CIFAR-10 data scenarios:
For each clean test image, we draw k = 8 independent noise realizations, embed all of them with the frozen backbone, and run a one-way ANOVA on the embeddings grouped by clean-image identity:
- S_W = mean within-image variance (the 8 embeddings of the same clean image spread apart only because the noise differs), i.e noise-driven variance
- S_B = between-image variance (different images) - i.e content
Our primary metric is then:
Where ICC is the standard one-way intraclass correlation coefficient (equivalently
1 − ICC = 1 − η², the complement of the ANOVA effect size).
- Lower
1 − ICC= the representation barely moves when only the noise changes = more noise-invariant. - We also clarify that all measurements are forward passes on frozen backbones
Table 1:
| Noise Cond. | Baseline (1- ICC) | SEANA (1 - ICC) | Reduction |
|---|---|---|---|
| Gauss_Low | 0.0212 | 0.0126 | -40% |
| Gauss_High | 0.1147 | 0.0630 | -45% |
| PG_Low | 0.0262 | 0.0195 | -26% |
| PG_High | 0.0792 | 0.0509 | -36% |
| Speckle_Low | 0.0203 | 0.0156 | -23% |
| Speckle_High | 0.0513 | 0.0360 | -30% |
At high noise ~5–11% of the baseline embedding's variance is pure noise, SEANA cuts that fraction by a third to a half.
We also investigate why denoising-only fails from this angle:
- Note: We use Next-Scale Prediction (NSP) SSL Denoiser as it is the most recent SOTA SSL Denoiser (CVPR'26) [1] and in our additional experiments below, we saw it outperformed Neighbor2Neighbor (N2N)
- Additional Metrics:
- Content re-ID: nearest-neighbor retrieval of the same clean image across two independent noise draws.
- High = content survives the noise.
- Effective rank (
eff_rank): participation ratio of the embedding covariance = effective dimensionality.
- Content re-ID: nearest-neighbor retrieval of the same clean image across two independent noise draws.
Table 2 (Gauss_High Noise Scenario:)
| Approach | 1 - ICC | S_W (Noise) | S_B (Content) | eff_rank | content re-ID |
|---|---|---|---|---|---|
| Baseline | 0.115 | 144.5 | 1049 | 31.2 | 0.786 |
| NSP | 0.206 | 42.6 | 175 | 7.1 | 0.247 |
| SEANA | 0.063 | 84.4 | 1235 | 24.5 | 0.905 |
- NSP removes the most absolute noise (S_W 42.6 vs 144.5) yet has the worst
1 − ICC, because its content variance collapses 6× (S_B 1049→175) and dimensionality crashes (eff_rank 31→7). - Denoising alone strips the variance the SSL objective needs to stay non-degenerate.
- SEANA restores it (SEANA S_B 1235, eff_rank 24.5, content re-ID 0.79→0.91).
Rebuttal Part 2
Q2. In the synthetic experiments, how does SEANA compare to oracle noise-aligned augmentation, analytic VST plus resampling, and raw-domain noise resampling when the true noise model is known?
In the synthetic noisy CIFAR-10 experiment, we compare SEANA to oracle noise-aligned augmentation, analytic VST plus resampling, and raw-domain noise resampling when the true noise model is known across all noise regimes. Each low and high noise regime below is the same as in the original synthetic noisy CIFAR-10 experiment:
Table 1 (Summary):
| Rank | Approach | Required External Knowledge | Mean Accuracy (%) | Mean Gain vs. Ref (+pp) | Median Gain (+pp) | Gain Range [Min, Max] |
|---|---|---|---|---|---|---|
| — | Oracle (Upper Bound) | True clean image + exact noise model | 59.37% | +16.69 | +16.50 | [+7.0, +27.0] |
| 1 | SEANA | Nothing | 57.68% | +15.01 | +14.15 | [+5.9, +26.6] |
| 2 | Analytical VST + Resample | Noise Family | 54.86% | +12.18 | +12.85 | [+1.8, +22.8] |
| 3 | NSP + Resample | Exact noise model | 53.24% | +10.56 | +11.55 | [-2.0, +19.8] |
| 4 | NSP | Nothing | 46.35% | +3.67 | +2.25 | [-1.9, +16.4] |
| 5 | N2N + Resample | Exact noise model | 45.68% | +3.00 | +4.65 | [-8.6, +14.0] |
| 6 | N2N | Nothing | 43.49% | +0.82 | +0.20 | [-4.6, +7.0] |
| — | Baseline (Ref) | - | 42.68% | 0.00 | 0.00 | [0.0, 0.0] |
Table 2 (Full)
| Noise Cond. | SSL | N2N | NSP | N2N + Resample | NSP + Resample | Analytical VST + Resample | SEANA | Oracle | Baseline (Ref) |
|---|---|---|---|---|---|---|---|---|---|
| Gauss_Low | BYOL | 51.8 | 54.4 | 57.6 | 57.4 | 60.7 | 60.8 | 61.4 | 52.3 |
| SimCLR | 59.8 | 58.6 | 62.3 | 58.1 | 61.9 | 66.0 | 67.2 | 60.1 | |
| VICReg | 64.8 | 61.7 | 67.3 | 64.6 | 69.3 | 69.4 | 69.5 | 62.5 | |
| Gauss_High | BYOL | 22.9 | 25.8 | 26.9 | 40.3 | 41.0 | 41.9 | 49.3 | 27.5 |
| SimCLR | 28.1 | 29.2 | 36.1 | 40.5 | 42.5 | 42.2 | 49.1 | 22.1 | |
| VICReg | 30.1 | 28.9 | 38.3 | 43.8 | 43.4 | 47.4 | 50.1 | 30.8 | |
| PG_Low | BYOL | 48.0 | 48.9 | 52.9 | 56.8 | 59.6 | 59.9 | 59.9 | 46.5 |
| SimCLR | 53.5 | 57.4 | 58.7 | 56.9 | 61.8 | 65.0 | 64.8 | 51.1 | |
| VICReg | 56.9 | 60.0 | 64.6 | 64.3 | 68.7 | 69.1 | 69.7 | 58.7 | |
| PG_High | BYOL | 27.5 | 35.7 | 23.8 | 45.7 | 44.5 | 47.8 | 51.6 | 29.7 |
| SimCLR | 29.2 | 37.6 | 28.6 | 47.0 | 41.1 | 50.5 | 52.3 | 27.2 | |
| VICReg | 31.1 | 33.0 | 30.3 | 51.8 | 53.0 | 54.7 | 54.7 | 32.1 | |
| Speckle_Low | BYOL | 51.3 | 51.2 | 56.6 | 57.7 | 59.0 | 61.5 | 61.6 | 52.1 |
| SimCLR | 58.8 | 59.8 | 63.1 | 58.8 | 59.5 | 67.0 | 67.4 | 55.5 | |
| VICReg | 61.0 | 63.2 | 68.8 | 66.6 | 67.3 | 71.4 | 71.7 | 63.7 | |
| Speckle_High | BYOL | 34.4 | 36.1 | 29.2 | 46.8 | 46.8 | 50.1 | 54.0 | 30.3 |
| SimCLR | 35.1 | 44.5 | 27.8 | 47.9 | 46.7 | 54.7 | 54.5 | 28.1 | |
| VICReg | 38.6 | 48.3 | 29.3 | 53.3 | 60.7 | 58.9 | 59.8 | 37.9 |
Rebuttal Part 3
Q3. Can the authors evaluate BBBC048 using a more stringent held-out split, such as by plate, batch, acquisition condition, or field of view?
Concern/Weakness: "Additional real scientific imaging datasets with different noise profiles would also strengthen the significance of the work."
We would like to clarify the BBBC048 dataset. It used the Amnis ImageStream platform, which is a fluorescence imaging instrument, producing fluorescence micrographs and is specifically considered a imaging flow cytometer [2].
In this modality, each cell is imaged individually as it passes the objective, so unlike plate microscopy there is no field of view shared by multiple cells and no plate or well structure. Thus, cells cannot share a parent image across the split.
Furthermore, the BBBC cell-cycle data does not distribute any plate/well/batch/replicate/session/timestamp field. To minimize confusion, we will rename Section 5.3 to "SSL on Real-World Single-Cell Fluorescence Imaging with Signal-Dependent Noise", name imaging flow cytometry explicitly at first mention in the abstract and Section 5.3, and extend Appendix D with the metadata availability.
Additional real scientific imaging dataset with different noise profile
We additionally utilize the Fetal Planes DB Dataset [3]. This ultrasound imaging dataset consists of maternal-fetal screening ultrasound images collected from different hospitals, several operators, and different ultrasound machines, divided into six classes: 4 are the most widely used fetal anatomical planes (Abdomen, Brain, Femur and Thorax), the mother’s cervix (widely used for prematurity screening), and a general category to include any other less common image plane.
Ultrasound imaging is quite distinct from the photon imaging-based modality seen in BBBC048, as it involves a transducer sending out high-frequency sound waves that travel through the body.
The dataset consists of over 12,400 images from 1,792 patients, with the authors of this dataset mentioning in their paper that it, "represents a real clinical scenario" [3]. We follow the official paper's split by patient, with a train of (6,400 images / 806 patients), a val of (715 images / 90 patients), and a test of (5,271 images / 896 patients).
- Additionally, we observe the dataset contains an implicit ultrasound machine / device domain-shift in Voluson E10
| Ultrasound Machine | % of train | % of test | % of its images in test |
|---|---|---|---|
| Voluson E6 | 48.5% | 45.7% | 41% |
| Aloka | 47.4% | 33.0% | 34% |
| Voluson E10 | 0.15% | 20.3% | 99% |
| Other | 4.0% | 1.1% | 17% |
We followed the same SSL model training and linear probing setup as the main experiments. We measured the macro-F1 score as our main metric as well as give a secondary per-class anatomical breakdown and accuracy measurement on device domain-shift in Voluson E10, to provide greater clinical insight into what SEANA is impacting.
We present the below results (macro F1 of linear probe) across the following SSL methods across 3 seeds:
- SimCLR, BYOL, VICReg, MoCoV2 [4], LeJEPA [5]
- Across all SSL methods, SEANA provides neutral to positive gains on macro F1.
Table 6: Fetal Planes DB Results
| SSL Method | Baseline | NSP + SSL | SEANA |
|---|---|---|---|
| SimCLR | 65.57 +- 0.12 | 66.64 +- 0.39 | 71.01 +- 0.14 |
| VICReg | 65.39 +- 0.19 | 64.55 +- 0.27 | 68.79 +- 0.52 |
| LeJEPA | 67.41 +- 0.03 | 68.15 +- 0.08 | 69.22 +- 0.04 |
| BYOL | 71.11 +- 0.07 | 71.44 +- 0.12 | 72.06 +- 0.08 |
| MoCoV2 | 69.11 +- 0.08 | 68.77 +- 0.01 | 69.24 +- 0.07 |
Table 7: Per-Class Anatomical Breakdown
| SSL Method | Approach | Brain | Thorax | Cervix | Abdomen | Femur | Other | Macro |
|---|---|---|---|---|---|---|---|---|
| SimCLR | Baseline | 78.7 | 65.5 | 92.5 | 44.0 | 43.0 | 69.7 | 65.6 |
| SimCLR | SEANA | 84.3 | 70.5 | 91.5 | 55.7 | 51.8 | 72.2 | 71.0 |
| VICReg | Baseline | 77.3 | 66.5 | 92.1 | 42.1 | 44.2 | 70.2 | 65.4 |
| VICReg | SEANA | 82.3 | 70.1 | 90.4 | 51.4 | 47.8 | 70.8 | 68.8 |
| LeJEPA | Baseline | 78.3 | 69.5 | 91.6 | 43.3 | 51.2 | 70.6 | 67.4 |
| LeJEPA | SEANA | 82.8 | 70.2 | 90.7 | 51.8 | 48.9 | 70.9 | 69.2 |
| MoCoV2 | Baseline | 81.6 | 70.0 | 91.8 | 50.1 | 50.4 | 70.8 | 69.1 |
| MoCoV2 | SEANA | 81.9 | 70.5 | 91.0 | 48.6 | 52.3 | 71.1 | 69.2 |
| BYOL | Baseline | 82.1 | 71.8 | 95.9 | 51.2 | 53.6 | 72.1 | 71.1 |
| BYOL | SEANA | 83.7 | 72.8 | 96.0 | 55.2 | 51.8 | 72.9 | 72.1 |
Q3. Continued below
- Rating
- 5/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper studies representation learning under signal-dependent noise. It proposes SEANA, a simple plugin that combines a learned variance-stabilizing transform (VST) with an off-the-shelf denoiser. VST reduces the mismatch between signal-dependent noise and the noise model assumed by the denoiser, allowing the denoiser to be used without retraining. The subsequent noise resampling step encourages the augmented views to preserve semantic content while varying noise patterns. The motivation and design choices are well justified through thorough ablation studies. Experiments on synthetic noise settings using CIFAR and ImageNet, as well as a real fluorescence microscopy dataset, show clear performance gains, supporting the effectiveness of the proposed method.
Strengths and weaknesses
Strengths
S1. The motivation is clear, and the design is simple and well justified. Using a learned variance-stabilizing transform to adapt signal-dependent noise to a standard denoiser provides a practical plugin for SSL augmentation.
S2. The method shows significant performance gains in both synthetic and real noise settings.
Weaknesses
W1. The paper lacks sufficient explanation of the BYOL collapse observed in Table 5 and Figure 3 under the “resampling only” setting. This may indicate that the method depends on the choice of SSL framework. A broader evaluation with other popular SSL methods, such as DINO and I-JEPA, would strengthen the paper.
W2. The role of appearance augmentation is unclear. SSL methods usually rely on strong augmentations such as color jittering, Gaussian blur, and grayscale conversion, but these components seem to be missing from Figure 1(a) and Figure 1(b). In particular, the resampling step in Figure 1(b) appears to partially overlap with the role of appearance augmentation. Clarifying the difference between these components would improve the presentation.
W3. (Minor) The axis labels in Figure 2 are too small. In Tables 2 and 3, it would be easier to compare results if each noise type were placed in the same row.
Questions
Q1. In Figure 1(b), is the same spatial augmentation applied to the two augmented views? Spatial augmentation is important in SSL for preserving semantic consistency across views. It would be helpful to clarify whether SEANA applies identical spatial transformations to the two views.
Q2. The paper notes that Lu et al. [17] performs worse than the Neighbor2Neighbor plus SSL setup. However, it would still be useful to include its results in the real noise study in Table 4. Besides, since Lu et al. [17] trains a dataset-specific denoiser, please also clarify why SEANA can outperform it despite using a more general denoising pipeline.
Limitations
Yes
Final justification
The rebuttal substantially addressed my concerns. In particular, the stronger NSP denoising baseline, broader SSL evaluation, and the new ICC-based representation analysis provide more convincing evidence that SEANA reduces noise sensitivity while preserving useful content. I therefore raise my rating from Borderline Accept to Accept.
Formatting concerns
No specific
5 comments
Rebuttal Part 1
Thank you for your clear and thorough feedback. We are happy to hear that you appreciated the motivation for studying this problem and thus the development of SEANA, the simplicity and justification of SEANA's methodological design and its practicality for SSL augmentation, and the good performance gains on synthetic/real noise settings.
Q1. In Figure 1(b), is the same spatial augmentation applied to the two augmented views? Spatial augmentation is important in SSL for preserving semantic consistency across views. It would be helpful to clarify whether SEANA applies identical spatial transformations to the two views.
Yes, the same spatial augmentation is applied to the two augmented views. SEANA slots into traditional augmentation pipelines where such spatial augmentations are performed as standard beforehand before SEANA performs its operations to produce independent noise views.
Q2. The paper notes that Lu et al. [17] performs worse than the Neighbor2Neighbor plus SSL setup. However, it would still be useful to include its results in the real noise study in Table 4. Besides, since Lu et al. [17] trains a dataset-specific denoiser, please also clarify why SEANA can outperform it despite using a more general denoising pipeline.
To better study why SEANA can outperform dataset-specific denoiser approaches (whether they be dataset-specific denoisers alone or dataset-specific denoiser guided approaches such as Lu et al. which are dependent on the quality of dataset-specific denoisers), we first compare SEANA against a more recent SOTA SSL Denoiser. We leverage Next-Scale Prediction (NSP) denoiser [1], a SSL Denoising paradigm recently introduced in CVPR '26 (June 2026) where they greatly outperformed Neighbor2Neighbor (N2N) which was used in our paper, as well as outperforming other recent SSL denoisers. As an example, NSP achieved a PSNR of 37.02 and an SSIM of 0.8865 on the SIDD Dataset in contrast to Neighbor2Neighbor which sat at PSNR of 28.00 and SSIM of 0.5890. NSP is, to our knowledge, the current SOTA SSL Denoiser.
On CIFAR-10's synthetic high noisy data regimes, we compared N2N-denoising alone, NSP-alone, DRUNet-alone (SEANA used frozen DRUNet as gaussian denoiser for its main paper experiments), and SEANA's learned VST + DRUNet in terms of PSNR to evaluate which produces the cleanest estimate:
Table 1: PSNR of Denoisers on CIFAR-10 Noisy. Each high noise condition is the same as that used in the main paper for CIFAR-10 synthetic high-noise regime experiments.
| Noise Cond. | N2N | NSP | DRUNet | DRUNet + VST (SEANA) |
|---|---|---|---|---|
| Gauss_High | 13.46 | 17.55 | 16.90 | 17.96 |
| PG_High | 15.00 | 18.44 | 15.97 | 19.96 |
| Speckle_High | 16.00 | 18.76 | 13.56 | 20.13 |
As seen above, DRUNet by itself is actually a weaker denoiser than NSP. However, by leveraging SEANA's learned VST, DRUNet is better able to adapt to the noise characteristics in each high noise data regime, allowing for SEANA to produce cleaner estimates (outperforming NSP).
Further, we find that in synthetic noisy CIFAR-10 scenarios, SEANA is able to outperform the following in Table 2 below:
- NSP denoising alone
- N2N denoising alone
- N2N + Resampling with the True/Known Noise Model
- NSP + Resampling with the True/Known Noise Model
- We note that in practical reality, it would be difficult to resample with the true noise model, so this represents an upper bound of generic noise resampling with NSP
Rebuttal Part 2
*Note: Oracle Noise-Aligned Augmentation: We take the original clean data + Resampling with the True/Known Noise Model, represents an upper ceiling
Table 2:
| Noise Cond. | SSL | N2N | N2N + Resample | NSP | NSP + Resample | SEANA | Oracle | Baseline (Ref) |
|---|---|---|---|---|---|---|---|---|
| Gauss_Low | BYOL | 51.8 | 57.6 | 54.4 | 57.4 | 60.8 | 61.4 | 52.3 |
| SimCLR | 59.8 | 62.3 | 58.6 | 58.1 | 66.0 | 67.2 | 60.1 | |
| VICReg | 64.8 | 67.3 | 61.7 | 64.6 | 69.4 | 69.5 | 62.5 | |
| Gauss_High | BYOL | 22.9 | 26.9 | 25.8 | 40.3 | 41.9 | 49.3 | 27.5 |
| SimCLR | 28.1 | 36.1 | 29.2 | 40.5 | 42.2 | 49.1 | 22.1 | |
| VICReg | 30.1 | 38.3 | 28.9 | 43.8 | 47.4 | 50.1 | 30.8 | |
| PG_Low | BYOL | 48.0 | 52.9 | 48.9 | 56.8 | 59.9 | 59.9 | 46.5 |
| SimCLR | 53.5 | 58.7 | 57.4 | 56.9 | 65.0 | 64.8 | 51.1 | |
| VICReg | 56.9 | 64.6 | 60.0 | 64.3 | 69.1 | 69.7 | 58.7 | |
| PG_High | BYOL | 27.5 | 23.8 | 35.7 | 45.7 | 47.8 | 51.6 | 29.7 |
| SimCLR | 29.2 | 28.6 | 37.6 | 47.0 | 50.5 | 52.3 | 27.2 | |
| VICReg | 31.1 | 30.3 | 33.0 | 51.8 | 54.7 | 54.7 | 32.1 | |
| Speckle_Low | BYOL | 51.3 | 56.6 | 51.2 | 57.7 | 61.5 | 61.6 | 52.1 |
| SimCLR | 58.8 | 63.1 | 59.8 | 58.8 | 67.0 | 67.4 | 55.5 | |
| VICReg | 61.0 | 68.8 | 63.2 | 66.6 | 71.4 | 71.7 | 63.7 | |
| Speckle_High | BYOL | 34.4 | 29.2 | 36.1 | 46.8 | 50.1 | 54.0 | 30.3 |
| SimCLR | 35.1 | 27.8 | 44.5 | 47.9 | 54.7 | 54.5 | 28.1 | |
| VICReg | 38.6 | 29.3 | 58.9 | 37.9 | 58.9 | 59.8 | 37.9 |
Oracle Noise-Aligned Augmentation is the clear ceiling and highlights that an ideal method would produce a completely clean version of the data and resample with the exact true/known noise model. As such, SEANA's use of a learned VST is what allows it to outperform dataset-specific denoiser based approaches in spite of using a more general (frozen) denoising pipeline, through the learned VST it is the closest to producing an initial clean estimate.
We also try to directly measure how baseline representations encode noise and how dataset-specific denoising and SEANA directly influence these representations. We show the following in the main paper's synthetic noisy CIFAR-10 data scenarios:
For each clean test image, we draw k = 8 independent noise realizations, embed all of them with the frozen backbone, and run a one-way ANOVA on the embeddings grouped by clean-image identity:
- S_W = mean within-image variance (the 8 embeddings of the same clean image spread apart only because the noise differs), i.e noise-driven variance
- S_B = between-image variance (different images) - i.e content
Our primary metric is then:
Where ICC is the standard one-way intraclass correlation coefficient (equivalently
1 − ICC = 1 − η², the complement of the ANOVA effect size).
- Lower
1 − ICC= the representation barely moves when only the noise changes = more noise-invariant. - We also clarify that all measurements are forward passes on frozen backbones
Additional Metrics:
- Content re-ID: nearest-neighbor retrieval of the same clean image across two independent noise draws.
- High = content survives the noise.
- Effective rank (
eff_rank): participation ratio of the embedding covariance = effective dimensionality.
Table 3:
| Noise Cond. | Baseline (1- ICC) | SEANA (1 - ICC) | Reduction |
|---|---|---|---|
| Gauss_Low | 0.0212 | 0.0126 | -40% |
| Gauss_High | 0.1147 | 0.0630 | -45% |
| PG_Low | 0.0262 | 0.0195 | -26% |
| PG_High | 0.0792 | 0.0509 | -36% |
| Speckle_Low | 0.0203 | 0.0156 | -23% |
| Speckle_High | 0.0513 | 0.0360 | -30% |
At high noise ~5–11% of the baseline embedding's variance is pure noise, SEANA cuts that fraction by a third to a half.
Rebuttal Part 3
Q2. Continued:
Why dataset-specific denoising-only fails from this angle:
Table 4 (Gauss_High Noise Scenario:)
| Approach | 1 - ICC | S_W (Noise) | S_B (Content) | eff_rank | content re-ID |
|---|---|---|---|---|---|
| Baseline | 0.115 | 144.5 | 1049 | 31.2 | 0.786 |
| NSP | 0.206 | 42.6 | 175 | 7.1 | 0.247 |
| SEANA | 0.063 | 84.4 | 1235 | 24.5 | 0.905 |
- NSP removes the most absolute noise (S_W 42.6 vs 144.5) yet has the worst
1 − ICC, because its content variance collapses 6× (S_B 1049→175) and dimensionality crashes (eff_rank 31→7). - Denoising alone strips the variance the SSL objective needs to stay non-degenerate.
- SEANA restores it (SEANA S_B 1235, eff_rank 24.5, content re-ID 0.79→0.91).
W1. The paper lacks sufficient explanation of the BYOL collapse observed in Table 5 and Figure 3 under the “resampling only” setting. This may indicate that the method depends on the choice of SSL framework. A broader evaluation with other popular SSL methods, such as DINO and I-JEPA, would strengthen the paper.
We look toward doing a broader evaluation of SSL methods on the BBBC048 (Real Fluorescence Imaging) Dataset used in the main paper below.
We did not go forward with I-JEPA on BBBC048, the real noise dataset currently used in the main paper, due to its need for reliance on Vision Transformers. At the scale of BBBC048 (~26k Images), even a ViT-tiny would not allow I-JEPA to serve as a robust SSL baseline to truly evaluate SEANA's influence on SSL in this real bioimaging noisy data scenario.
Instead, we select LeJepa [2]. LeJEPA is considered the successor/optimization to I-JEPA/overall JEPA family. Additionally, LeJepa is inspired by DINO's multi-crop (global/local) view approach.
BBBC048 (Real Fluorescence Imaging Dataset) - Extended Evaluation:
We also then evaluate NSP + SSL in BBBC048, for the following SSL methods, across 3 seeds on Linear Probe Top-1 Accuracy:
- SimCLR, VICReg, BYOL, MoCoV2 [3], LeJEPA Table 5:
| SSL Method | Baseline | NSP + SSL | SEANA |
|---|---|---|---|
| BYOL | 63.4 +- 3.4 | 67.9 +- 2.3 | 75.7 +- 0.1 |
| SimCLR | 46.9 +- 0.3 | 46.6 +- 0.6 | 75.5 +- 0.1 |
| VICReg | 46.8 +- 0.2 | 48.6 +- 0.3 | 74.4 +- 0.2 |
| LeJEPA | 47.5 +- 0.4 | 49.3 +- 0.4 | 74.4 +- 0.3 |
| MoCoV2 | 71.5 +- 1.9 | 73.9 +- 0.1 | 75.1 +- 0.6 |
| SSL Method | Baseline | VST-Only | Resampling-Only | SEANA (Full) |
|---|---|---|---|---|
| BYOL | 63.4 +- 3.4 | 59.6 +- 0.1 | 46.5 +- 0.2 | 75.7 +- 0.1 |
| SimCLR | 46.9 +- 0.3 | 47.3 +- 0.5 | 74.2 +- 0.0 | 75.5 +- 0.1 |
| VICReg | 46.8 +- 0.2 | 46.1 +- 1.0 | 73.3 +- 0.1 | 74.4 +- 0.2 |
| LeJEPA | 47.5 +- 0.4 | 47.6 +- 0.3 | 73.23 +- 0.1 | 74.4 +- 0.3 |
| MoCoV2 | 71.5 +- 1.9 | 66.75 +- 0.1 | 68.1 +- 1.1 | 75.1 +- 0.6 |
- We see MocoV2 suffers similar to BYOL, in that generic noise resampling alone harms it.
- It seems that Momentum-based SSL methods are more fragile to generic noise resampling and can lead to collapse. SEANA's full pipeline is what rescues these methods.
These observations align with the larger literature/SSL community shift away from momentum-based SSL approaches due to their fragility. SEANA benefits both momentum and non-momentum SSL methods. Non-momentum SSL methods tend to start at a lower floor/baseline in signal-dependent noisy imaging data, necessitating SEANA.
W2. The role of appearance augmentation is unclear. SSL methods usually rely on strong augmentations such as color jittering, Gaussian blur, and grayscale conversion, but these components seem to be missing from Figure 1(a) and Figure 1(b). In particular, the resampling step in Figure 1(b) appears to partially overlap with the role of appearance augmentation. Clarifying the difference between these components would improve the presentation.
To clarify, we still rely on traditional SSL appearance augmentations within the SEANA integrated augmentation pipeline. Specifically, spatial augmentations (such as random crops/flips etc) are first carried out, then SEANA performs its operations to produce independent noisy views, and afterwards traditional appearance augmentations (such as color jitter etc) are carried out.
For example, in the CIFAR-10 experiments in the main paper, after SEANA's operations, we utilize default LightlySSL library [4] appearance augmentations for SimCLR, VICReg, and BYOL, some ex: ColorJitter with RandomApply, RandomGrayscale, RandomSolarization
We shall update Figure 1(a) and 1(b) to more clearly showcase how traditional appearance augmentations are integrated, specifically showcasing that SEANA slots into traditional augmentation pipelines that leverage spatial/appearance augmentations.
Comments on the paper
1 comment
Dear Reviewers,
Thanks for your time and efforts to help review this submission and join the discussion. As we approach the end of reviewer-author discussion phase, please follow up to the author if there is still any remaining concern.
Thanks,
AC
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Rebuttal Part 1
We are happy to hear that, pre-rebuttal, the reviewers already appreciated the importance of studying this problem and its relevance for scientific imaging, our experimental coverage being overall comprehensive, the strength of our method's results/performance gain in real/synthetic data, our method (SEANA) being well motivated by previous theoretical work in SSL, the parameter efficiency of SEANA in contrast to dataset-specific denoisers, and that it flexibly plugs-in with existing joint-embedding SSL methods.
We thank the Area Chair for their guidance on relevant concerns that need to be addressed.
To directly measure measure whether baseline representations encode noise and that SEANA, the proposed method, reduces it, we show the following:
For each clean test image, we draw k = 8 independent noise realizations, embed all of them with the frozen backbone, and run a one-way ANOVA on the embeddings grouped by clean-image identity, on the synthetic noisy CIFAR-10 dataset regimes:
Our primary metric is then:
Where ICC is the standard one-way intraclass correlation coefficient (equivalently
1 − ICC = 1 − η², the complement of the ANOVA effect size).1 − ICC= the representation barely moves when only the noise changes = more noise-invariant.Table 1:
At high noise ~5–11% of the baseline embedding's variance is pure noise, SEANA cuts that fraction by a third to a half.
We also investigate why denoising-only fails from this angle:
eff_rank): participation ratio of the embedding covariance = effective dimensionality.Table 2 (Gauss_High Noise Scenario:)
1 − ICC, because its content variance collapses 6× (S_B 1049→175) and dimensionality crashes (eff_rank 31→7).