Multi-Level Alignment Framework for Long-Term Olfactory Neural Decoding
Xu Bohao, Jiawei Zeng, Gang Yu, Lei Wang, Duanduan Chen, Xiaoying Tang, Tianyi Qian
NeurIPS 2026
Abstract. Achieving stable neural decoding over extended periods remains challenging because changes in neural recordings and representational drift can impair generalization across recording sessions. This work introduces the Long-term Neural Decoding Network (LNDN), a hierarchical framework designed to disentangle category-specific neural dynamics from representational drift and maintain decoding accuracy without periodic supervised recalibration. The proposed architecture addresses representational drift through an integrated tri-level alignment strategy. At the physical feature level, a decoupled representation and dynamic gating module isolates the physical identity of neurons from their transient states, adaptively filtering stochastic neural noise. This is further strengthened at the decision level by a Mixture-of-Experts (MoE) architecture, which employs a parallel soft-voting mechanism to suppress high variance induced by local representational distortions. Finally, at the manifold level, Adaptive Batch Normalization (AdaBN), latent contrastive learning, and second-order correlation alignment are combined to promote the geometric consistency of the low-dimensional neural manifold over a period of months. In a four-odor classification task, LNDN was trained exclusively on data from the first four weeks and achieved a mean decoding accuracy of 83.67% over the subsequent eight weeks without supervised recalibration. This framework provides a stable decoding approach for long-term invasive olfactory brain–computer interfaces without periodic supervised recalibration.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:43 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
Initial meta-review
This paper addresses the problem of designing long-term olfactory bulb neural decoders that do not require realignment.
The problem is important, yet challenging because biological variability (due to neurogenesis) and measurement variability (due to electrode movement) are entangled. Moreover, there is limited available training data.
The main strength of the paper is that the method outperforms previous approaches (that were tested).
The main weaknesses are:
- The paper offers relatively little motivation about why their approach is appropriate (most of the paper is Methods, Experiments, Results).
- The reviewers raised several questions related to the methodology and comparisons to baselines.
My overall impression is that if the method robustly outperforms existing approaches, then that is a meaningful result (though a theoretical understanding of why would be more satisfying). However, the authors need to address the reviewers' concerns about the efficacy of their method.
Final meta-review
I have read the authors' rebuttal and the reviewers' responses. The final assessments by the reviewers are mixed.
Reviewer hxAG wrote
The authors ran every analysis I asked for, including the ones that did not favour them.
The authors addressed most of their concerns.
Reviewer TmZf maintained a positive assessment, but lowered their score from a 5 to a 4, writing
The framework primarily assembles existing well-established techniques (lightweight cross-attention, AdaBN, Deep CORAL, and template matching) into a systematic pipeline, rather than introducing a fundamentally novel computational paradigm
Reviewer 3gev stated that they still have concerns, writing
The manuscript still contains a large number of unexplained acronyms and requires significant changes. This paper should compare the proposed approach with more recent methods that were published in 2026. Due to these reasons, I do not change my score.
First, regarding the acronyms, according to the NeurIPS guidelines "authors may not submit revisions of their paper or supplemental material", so they are unable to edit the acronyms. Instead, they wrote "In the revised manuscript, we will expand less common acronyms (e.g., SSHD to "Small-Sample, High-Dimensional", OB to "Olfactory Bulb") throughout the text to improve readability."
Second, regarding comparing to baselines, the authors added baselines from 2021-2025. In addition, the guidelines state
For the purpose of the reviewing process, papers that appeared online after March 1st, 2026 will generally be considered "contemporaneous" in the sense that the submission will not be rejected on the basis of the comparison to contemporaneous work. Authors are still expected to cite and discuss contemporaneous work and perform empirical comparisons to the degree feasible.
Incorrect references The automated citation checked flagged the following ostensibly hallucinated reference:
The title 'Poyo: Spatiotemporal models for objective brain-computer interfaces' does not exist. The actual paper by Mehdi Azabou et al. introducing POYO is titled 'A unified, scalable framework for neural population decoding' (published in NeurIPS 2023, arXiv:2310.16046). Furthermore, the arXiv ID 2311.00423 corresponds to an unrelated paper titled 'LLMRec: Large Language Models with Graph Augmentation for Recommendation'.
The authors should correct this reference.
Final justification
As stated in the meta-review, the final reviews are mixed, with 2 reviewers recommending boderline accept and one reviewer recommending reject (Reviewer 3gev). Reviewer 3gev had 2 main concerns, one of which the authors promised to address and the other which falls outside the NeurIPS guidelines. Therefore, despite the negative review, I am recommending acceptance.
Read meta-review
Meta-review
Initial meta-review
This paper addresses the problem of designing long-term olfactory bulb neural decoders that do not require realignment.
The problem is important, yet challenging because biological variability (due to neurogenesis) and measurement variability (due to electrode movement) are entangled. Moreover, there is limited available training data.
The main strength of the paper is that the method outperforms previous approaches (that were tested).
The main weaknesses are:
- The paper offers relatively little motivation about why their approach is appropriate (most of the paper is Methods, Experiments, Results).
- The reviewers raised several questions related to the methodology and comparisons to baselines.
My overall impression is that if the method robustly outperforms existing approaches, then that is a meaningful result (though a theoretical understanding of why would be more satisfying). However, the authors need to address the reviewers' concerns about the efficacy of their method.
Final meta-review
I have read the authors' rebuttal and the reviewers' responses. The final assessments by the reviewers are mixed.
Reviewer hxAG wrote
The authors ran every analysis I asked for, including the ones that did not favour them.
The authors addressed most of their concerns.
Reviewer TmZf maintained a positive assessment, but lowered their score from a 5 to a 4, writing
The framework primarily assembles existing well-established techniques (lightweight cross-attention, AdaBN, Deep CORAL, and template matching) into a systematic pipeline, rather than introducing a fundamentally novel computational paradigm
Reviewer 3gev stated that they still have concerns, writing
The manuscript still contains a large number of unexplained acronyms and requires significant changes. This paper should compare the proposed approach with more recent methods that were published in 2026. Due to these reasons, I do not change my score.
First, regarding the acronyms, according to the NeurIPS guidelines "authors may not submit revisions of their paper or supplemental material", so they are unable to edit the acronyms. Instead, they wrote "In the revised manuscript, we will expand less common acronyms (e.g., SSHD to "Small-Sample, High-Dimensional", OB to "Olfactory Bulb") throughout the text to improve readability."
Second, regarding comparing to baselines, the authors added baselines from 2021-2025. In addition, the guidelines state
For the purpose of the reviewing process, papers that appeared online after March 1st, 2026 will generally be considered "contemporaneous" in the sense that the submission will not be rejected on the basis of the comparison to contemporaneous work. Authors are still expected to cite and discuss contemporaneous work and perform empirical comparisons to the degree feasible.
Incorrect references The automated citation checked flagged the following ostensibly hallucinated reference:
The title 'Poyo: Spatiotemporal models for objective brain-computer interfaces' does not exist. The actual paper by Mehdi Azabou et al. introducing POYO is titled 'A unified, scalable framework for neural population decoding' (published in NeurIPS 2023, arXiv:2310.16046). Furthermore, the arXiv ID 2311.00423 corresponds to an unrelated paper titled 'LLMRec: Large Language Models with Graph Augmentation for Recommendation'.
The authors should correct this reference.
Final justification
As stated in the meta-review, the final reviews are mixed, with 2 reviewers recommending boderline accept and one reviewer recommending reject (Reviewer 3gev). Reviewer 3gev had 2 main concerns, one of which the authors promised to address and the other which falls outside the NeurIPS guidelines. Therefore, despite the negative review, I am recommending acceptance.
1 comment
- Rating
- 2/6
- Confidence
- 4/5
- Quality
- 2/4
- Clarity
- 2/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This work tackles the central problem of representational drift in long-term neural decoding for olfactory brain-computer interfaces. The proposed method, LNDN (Long-term Neural Decoding Network), introduces a hierarchical tri-level alignment framework designed to maintain decoding stability over extended periods without requiring periodic recalibration.
At the physical level, a decoupled representation with dynamic gating separates neuronal identity from transient firing dynamics. At the decision level, a Mixture-of-Experts architecture with soft-voting is employed to mitigate variance arising from local distortions. At the manifold level, Adaptive Batch Normalization, contrastive objectives, and second-order correlation alignment are jointly used to preserve the geometric consistency of the neural manifold over time.
Strengths and weaknesses
Strengths:
-
The research topic is interesting.
-
This paper has a clear motivation.
Weakness:
-
A critical methodological issue is that the baseline comparisons are not conducted under equal conditions: LNDN uses all detected units with multi-modal inputs (firing activity + spike waveforms + neuron positions) All baseline models are restricted to manually tracked "common units" using only firing activity.
-
The experimental setup is quite limited: Only 4 odor classes: A 4-way classification task is relatively simple and may not sufficiently challenge the method. Small dataset: 9 mice, 12 weeks, 40 trials per session (10 per odor). This is a very small dataset by modern ML standards. Limited diversity: Only one brain region (olfactory bulb), one task type (odor classification), one animal species.
-
There is no formal analysis of why the three-level alignment strategy should work.
-
The choice of specific alignment methods (AdaBN, CORAL, contrastive) is not theoretically motivated.
-
The ablation study (Table 2) shows incremental improvements, but doesn't provide deep insight into why each component helps or how they interact.
-
The paper is densely written with many acronyms (SSHD, LNDN, MoE, AdaBN, CORAL, etc.), making it hard to follow.
-
Only cumulative ablations are shown, not ablations of individual components within each block.
-
The biological motivation (neurogenesis, respiration-coupled motion) is not directly incorporated into the model design.
Questions
Please see the weakness section.
Limitations
Yes.
Final justification
The manuscript still contains a large number of unexplained acronyms and requires significant changes. This paper should compare the proposed approach with more recent methods that were published in 2026. Due to these reasons, I do not change my score.
Formatting concerns
No
8 comments
Response to Q1: Unfair Baseline Comparisons
Author Response: We appreciate the reviewer's attention to fair benchmarking. Our original decision to restrict baselines to "manually tracked common units" was driven by three practical constraints: (1) Without cross-week common-unit tracking and alignment, traditional models incorporate chaotic and uninformative signals, ultimately leading to severe overfitting; (2) Standard decoders lack the architectural mechanisms to process multi-modal, variable-dimension inputs natively; (3) We used manual tracking to implicitly provide baselines with the benefit of waveform and position stability.
To address your concern regarding input parity, we have conducted multiple sets of new experiments evaluating the baselines under identical full-data conditions: All baselines use the same input as LNDN: firing matrices are zero-padded to capacity, with waveform and position vectors prepended to prevent temporal model (e.g., RNN/LSTM) hidden state collapse. Since native POYO requires continuous spike tokens and cannot accommodate auxiliary physical features, it is evaluated on its native raw spike tokens for comparison.
| Model Configuration | Accuracy | Precision | F1-Score |
|---|---|---|---|
| LNDN (full data) | 0.8367 ± 0.1644 | 0.8386 ± 0.1683 | 0.8298 ± 0.1702 |
| SVM (full data) | 0.4625 ± 0.0961 | 0.4248 ± 0.1570 | 0.3803 ± 0.1152 |
| CEBRA (full data) | 0.4412 ± 0.1092 | 0.3994 ± 0.1365 | 0.3596 ± 0.1216 |
| LDA (full data) | 0.4258 ± 0.0871 | 0.4180 ± 0.1060 | 0.3498 ± 0.0949 |
| RF (full data) | 0.4248 ± 0.0740 | 0.4311 ± 0.1051 | 0.3677 ± 0.0888 |
| XGBoost (full data) | 0.3878 ± 0.0698 | 0.3728 ± 0.1246 | 0.3218 ± 0.0916 |
| LSTM (full data) | 0.3564 ± 0.0852 | 0.3100 ± 0.1077 | 0.2755 ± 0.0914 |
| Transformer (full data) | 0.3431 ± 0.0663 | 0.2471 ± 0.0736 | 0.2387 ± 0.0654 |
| RNN (full data) | 0.3200 ± 0.0677 | 0.2615 ± 0.0886 | 0.2339 ± 0.0675 |
| POYO(Scratch) | 0.5089 ± 0.1041 | 0.5296 ± 0.1355 | 0.4820 ± 0.1183 |
| POYO(Pretrained) | 0.5046 ± 0.1082 | 0.5138 ± 0.1297 | 0.4702 ± 0.1258 |
The results demonstrate that standard baselines suffer severe performance degradation (falling below 50%) when exposed to the raw, un-tracked cross-week data due to severe noise overfitting. For this reason, we utilize cross-week aligned neurons specifically to ensure baseline models can be fairly compared against our method at their best achievable performance. We will include this exhaustive parity benchmark in the revised manuscript.
Response to Q2: Limited Experimental Setup
Author Response: We understand the reviewer's perspective regarding dataset scale from a general ML standpoint. However, we wish to clarify the unique difficulty and extreme scarcity of longitudinal invasive recordings:
- Task Difficulty: While a static 4-class decoding task is trivial on a single day, maintaining stability over 12 weeks under severe neural drift is an unsolved challenge. As shown in our Figure 3, the initial neural code completely decorrelates by week 8. Prior studies (e.g., Schoonover et al., Nature 2021) report that static decoders drop to chance levels after just 32 days.
- Dataset Scale: In chronic olfactory electrophysiology, tracking 9 mice for 12 weeks represents an exceptionally rare and challenging longitudinal dataset in the field. The vast majority of existing studies in this domain typically track only 4 to 8 animals over 2 to 6 weeks. For instance, Schoonover et al. (Nature 2021) investigated long-term olfactory representational drift using 6 mice over 32 days (3 with 8 odors and 3 with 4 odors), while Herrero-Vidal et al. (NeurIPS 2021) focused on olfactory decoding across 5 animals without longitudinal tracking. Therefore, our dataset of 9 mice across 12 weeks provides an exceptionally demanding benchmark environment along the temporal dimension. Furthermore, the constraint of 40 trials per session is directly mandated by biological sensory adaptation in the olfactory system. Excessive odor trials within a single session induce severe olfactory bulb neuron desensitization, introducing non-task-related response decay—which is precisely why single-session trial counts remain naturally limited in olfactory electrophysiology literature.
- Diversity vs. Focus: Olfactory BCIs hold immense practical value, especially given the current lack of effective artificial chemical sensors. However, olfactory decoding faces strict physiological constraints: due to rapid sensory adaptation, animals cannot be continuously exposed to odor stimuli without inducing neural desensitization. Furthermore, chronic electrode implantation in the Olfactory Bulb is exceptionally challenging anatomically, resulting in an extreme scarcity of publicly available chronic electrophysiological datasets. Unlike motor BCIs, olfactory BCIs currently lack the large-scale, long-term public datasets required to pre-train generalized neural foundation models. We deliberately focused on odor decoding precisely to address this sensory BCI bottleneck marked by the coexistence of data scarcity and severe long-term representational drift, thereby providing a targeted, domain-specific solution.
Response to Q3、Q4、Q8: Lack of Theoretical Motivation and Biological Incorporation
Author Response: We sincerely appreciate this constructive feedback. The tri-level alignment strategy was explicitly designed from the outset to directly counteract the biophysically motivated challenges inherent to long-term chronic electrode implants. Each level of our alignment framework directly maps to one or more of these concrete biological challenges:
-
Physical-Level Alignment (Addressing respiration-coupled micro-motion and signal decay): The Olfactory Bulb resides in a mechanically unstable environment where ongoing respiratory rhythms induce continuous physiological motion, leading to electrode micro-motion. Furthermore, glial encapsulation and changing cellular states cause signal decay. The "Decoupling and Dynamic Gating" module at the physical level counteracts these issues via the dynamic gating formulation:
The gating matrix functions as a differentiable biological confidence filter. When neuronal activity decays or drifts out of a recording channel's effective range, the resulting identity distortion forces . This effectively cuts off noisy features and compels the network to rely solely on invariant physical identities ().
-
Decision-Level Alignment (Addressing localized neurogenesis and neural remodeling): The Olfactory Bulb is a rare site of active adult neurogenesis, where continuous granule cell turnover dynamically reshapes local circuit connectivity. Consequently, specific local neural features distort or become obsolete over weeks. The parallel Mixture-of-Experts architecture at the decision level is deployed not merely for standard model ensembling, but to achieve biological fault tolerance. When neurogenesis causes localized channel silence or structural distortion, taking the expectation over parallel expert subspaces attenuates the high variance introduced by local circuit restructuring.
-
Manifold-Level Alignment (Addressing low-dimensional representational drift geometry): Existing literature (Gallego et al., Nature Neuroscience, 2020) has established that despite continuous neural turnover over long timescales, there exist stable low-dimensional latent dynamics. Therefore, our manifold alignment is designed precisely to identify a latent space composed of stable low-dimensional manifolds. Driven by chronic baseline fluctuations, electrode impedance changes, and neural remodeling, representational drift can be decomposed into a translation vector in the latent space (capturing baseline firing rate shifts) and a transformation matrix (capturing gain changes and feature rotation). Consequently, we formalize the neural manifold mapping for the same odor across different time points (Session to Session ) as a complete affine transformation:
The vector causes a rigid shift in the mean feature distribution across weeks. We employ Adaptive Batch Normalization (AdaBN) to re-center the target manifold:
Subtracting the target domain mean mathematically cancels out the rigid translation bias in expectation. However, even after eliminating , the manifold remains distorted by (encompassing rotation and scaling, akin to amLDS). Assuming , the source and target covariance matrices satisfy . To eliminate the distortion caused by , we must minimize the discrepancy between and , directly motivating the Deep CORAL loss:
By minimizing the Frobenius norm discrepancy between cross-session covariance matrices, the network theoretically learns an inverse transformation to neutralize the geometric deformations (rotation and scaling) induced by .
However, relying solely on AdaBN and CORAL introduces a theoretical vulnerability: both are global unsupervised constraints. Forcing global covariance alignment under small-sample regimes easily leads to inter-class manifold collapse or overlap. To safeguard discriminative geometric boundaries between odor categories during global alignment, an inter-class repulsive loss is theoretically required. Supervised Contrastive Learning serves this explicit purpose. This objective ensures that intra-class samples cluster together in the latent space while inter-class manifolds repel one another, explicitly preserving discriminative margins during global alignment.
We will add these formal theoretical proofs and biological mappings to a dedicated Appendix section.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
Long-term olfactory BCIs face drift from respiration-induced electrode motion and neurogenesis-driven circuit changes. This study proposes a decoder that avoids neuron tracking and frequent recalibration. It uses waveform and electrode position as stable identity features, and a gating mechanism separates stable firing from noise. Expert networks with soft voting handle local signal loss; covariance alignment and batch normalization reduce session drift and avoid large batches. An auxiliary loss preserves class separation. The decoder utilizes all detected neurons, not just common ones. Trained on four weeks and tested on later weeks, it outperforms baselines, and ablation confirms each module contributes.
Strengths and weaknesses
Strengths: The manuscript presents a solid contribution to chronic olfactory decoding by addressing the Small-Sample, High-Dimensional (SSHD) limitations often encountered in such datasets. The proposed LNDN framework effectively separates the physical identity of neurons from their transient firing states through a dynamic gating module. This design mitigates the need for strict cross-session unit tracking and reduces the data attrition that typically occurs when unmatched or transiently active neurons are discarded, thereby improving the overall utilization of limited biological data. Furthermore, rather than relying primarily on increased model capacity, the authors introduce a structured tri-level alignment strategy. The combination of physical-level noise filtration, a decision-level Mixture-of-Experts consensus, and manifold-level statistical alignment utilizing AdaBN and Deep CORAL successfully separates electrode noise from systemic drift. This comprehensive approach results in sustained decoding accuracy over the two-month longitudinal evaluation period. Weaknesses: While the LNDN framework demonstrates stable long-term decoding, its current architecture introduces computational overhead that challenges practical deployment on resource-constrained edge platforms. Specifically, the reliance on power-intensive spike sorting algorithms, matrix multiplications for the Mixture-of-Experts, and continuous high-dimensional covariance computations leaves the strategy for real-time execution on power-sensitive hardware undefined. Furthermore, the biological validity of the 200 ms random temporal shift augmentation remains unverified. Because precise phase coding is essential in rodent olfaction, a shift of this magnitude risks altering original spike timing and phase-locking relationships, indicating a need for quantitative analysis or ablation studies to justify this parameter choice. Finally, the physical identity decoupling module depends entirely on waveform templates and spatial coordinates extracted by frontend pipelines, making the system susceptible to performance drops during severe signal degradation in late-stage chronic recordings. The absence of boundary robustness tests under artificially lowered signal-to-noise ratio conditions currently limits a comprehensive understanding of the framework's operational boundaries.
Questions
- The LNDN framework demonstrates stable long-term decoding, but its current architecture introduces substantial computational overhead that challenges its practical deployment on resource-constrained edge platforms. Specifically, the physical layer relies on power-intensive spike-sorting algorithms, the decision layer involves heavy matrix multiplications for the Mixture-of-Experts, and the manifold layer demands continuous high-dimensional covariance computations. Given these dependencies, it is unclear how the system can be efficiently executed on power-sensitive hardware. Could the authors clarify their strategy for the real-time deployment of this framework in such environments?
- The framework utilizes a 200 ms random temporal shift augmentation to mitigate overfitting to temporal artifacts. Given that neural coding in rodent olfaction is closely coupled with respiratory rhythms, precise phase coding is typically essential for representing odor identity. Could the authors clarify whether a shift of this magnitude might alter the original spike timing and phase-locking relationships? I recommend providing a quantitative analysis to confirm that this operation preserves the necessary temporal codes. Have the authors considered an ablation study with varying temporal shift magnitudes? Including such data would greatly help the readers assess the biological validity of this specific parameter choice.
- Although the LNDN approach operates without tracking during the downstream decoding phase, the physical identity decoupling module remains dependent on waveform templates and spatial coordinates extracted by frontend spike sorting pipelines like Kilosort. I am curious about how the model handles severe signal degradation during late-stage chronic recordings. In such scenarios, might the physical layer lack the input fidelity required to accurately separate identity from state? Could the authors provide boundary robustness tests to explore this? Evaluating the model under artificially lowered signal-to-noise ratio (SNR) conditions would offer a much clearer understanding of this limitation and establish the framework's operational boundaries.
Limitations
YES
Final justification
After carefully reviewing the authors' rebuttal and re-evaluating the submission against the official NeurIPS rating criteria, I have decided to revise my final rating from 5 to 4 to better reflect the paper's true contribution scope. The rebuttal successfully addressed my technical concerns regarding computational overhead, temporal shift validity, and SNR robustness with new quantitative data. I acknowledge and appreciate these clarifications. However, upon closer scrutiny of the newly provided metrics and the overall architectural design, I find that the contribution, while technically solid and practically useful for the olfactory BCI community, does not quite cross the threshold for a 5 ("high potential value on at least one sub-area of AI or moderate-to-high impact on more than one area"). The framework primarily assembles existing well-established techniques (lightweight cross-attention, AdaBN, Deep CORAL, and template matching) into a systematic pipeline, rather than introducing a fundamentally novel computational paradigm. Given these considerations, the work is best characterized as a solid, well-executed engineering contribution with good performance which aligns precisely with the definition of a score of 4 ("good"), rather than a high-impact or transformative advance. I have adjusted my rating accordingly to maintain consistency with the NeurIPS standards.
Formatting concerns
n/a
5 comments
Response to Q3: Severe Signal Degradation
Author Response: We are grateful to the reviewer for raising this highly practical consideration regarding late-stage chronic interface degradation. To quantitatively explore LNDN's robustness boundaries and address your question about physical layer input fidelity, we conducted a comprehensive Signal-to-Noise Ratio (SNR) stress test.
Using the pre-trained LNDN model (trained strictly on clean data from Weeks 1-4), we artificially injected varying levels of additive Gaussian white noise to the spike waveforms (), applied spatial jitter to the neuron positions (), and degraded the firing activity matrices () during inference on the completely unseen future sessions (Weeks 5-12).
| Configuration | Waveform SNR | Position Jitter | Activity SNR | Accuracy | Accuracy |
|---|---|---|---|---|---|
| Clean (Baseline) | - | - | - | 83.67% ± 16.44% | 0.00% |
| W + P Degraded | 20 dB | 5 m | - | 69.78% ± 17.43% | -13.89% |
| W + P Degraded | 10 dB | 10 m | - | 67.79% ± 17.72% | -15.88% |
| W + P Degraded | 5 dB | 20 m | - | 66.22% ± 17.77% | -17.45% |
| W + P Degraded | 0 dB | 40 m | - | 64.48% ± 17.66% | -19.19% |
| W + P Degraded | -5 dB | 80 m | - | 62.88% ± 17.76% | -20.79% |
| X (Activity) Degraded | - | - | 10 dB | 82.18% ± 16.53% | -1.49% |
| X (Activity) Degraded | - | - | 0 dB | 78.06% ± 16.63% | -5.61% |
| All Degraded | 10 dB | 10 m | 10 dB | 65.02% ± 17.14% | -18.65% |
| All Degraded | 0 dB | 20 m | 0 dB | 56.80% ± 15.29% | -26.87% |
The results show a sharp initial drop in decoding accuracy when noise is introduced to the waveform and position features; however, the subsequent rate of degradation slows down significantly as noise levels increase further. Notably, the model exhibits high robustness when noise is applied exclusively to the firing activity, maintaining an accuracy of 78.06% even at an extreme 0 dB SNR. Severe performance degradation occurs primarily when extreme noise is simultaneously applied across all three modalities ("All Degraded"). Furthermore, a cross-comparison between the 'W+P Degraded' and 'All Degraded' conditions under identical noise levels (67.79% vs. 65.02% at 10 dB; 64.48% vs. 56.80% at 0 dB) demonstrates that when only the physical layer's neuron identity fidelity decreases, the firing activity features exhibit a degree of compensatory resilience against interference.
Response to Q2: Temporal Shift Augmentation
Author Response: We appreciate the reviewer's insightful question regarding the biological validity of the temporal shift augmentation. In fact, this mechanism was explicitly designed to help the model exploit true respiration phase-locked information while discarding arbitrary experimental timing artifacts.
In free-breathing rodents, the absolute timing of the odor valve opening varies randomly relative to the animal's ongoing respiratory phase. Consequently, the absolute temporal latency of odor-evoked spikes (relative to trial onset) fluctuates across trials of the exact same odor. The model must learn the invariant relative sequence of neuronal activations within a respiratory cycle, rather than their absolute timing relative to the arbitrary valve trigger. Our stochastic temporal shift ( ms) shifts the entire population firing matrix simultaneously (Equation 2 in Section 3.2).Therefore, the internal temporal structure and relative phase-locking relationships between all neurons within a trial are perfectly preserved, effectively preventing the model from overfitting to the biologically irrelevant absolute phase.
The ms magnitude was chosen because it roughly corresponds to one complete basal respiratory cycle of a mouse ($\sim$5 Hz). To quantitatively validate this parameter, we conducted the suggested ablation study varying the shift magnitude:
| Shift Magnitude | Accuracy | Precision | F1-Score |
|---|---|---|---|
| 0 ms | 80.93% ± 15.45% | 81.22% ± 15.97% | 80.44% ± 15.94% |
| 50 ms | 81.34% ± 16.27% | 81.77% ± 16.49% | 80.90% ± 16.65% |
| 100 ms | 82.49% ± 16.36% | 82.82% ± 16.82% | 82.00% ± 16.86% |
| 200 ms | 83.67% ± 16.44% | 83.86% ± 16.83% | 82.98% ± 17.02% |
| 300 ms | 83.43% ± 16.23% | 83.71% ± 16.62% | 82.91% ± 16.78% |
As shown, performance improves as the shift increases, plateauing around our selected 200 ms mark. This confirms that an insufficient shift fails to decouple the neural code from the absolute onset artifact, whereas a full respiratory cycle shift optimally forces the model to rely on robust relative temporal dynamics. We will incorporate this biological justification and ablation table into the revised Appendix.
Response to Q1: Hardware Efficiency and Real-time Deployment
We sincerely thank the reviewer for highlighting the critical requirement of hardware efficiency in practical Brain-Computer Interface (BCI) deployment. We completely understand the concerns regarding execution on resource-constrained edge platforms and would like to provide the following clarifications regarding our real-time deployment strategy:
- Manifold Layer (Deep CORAL): The high-dimensional covariance computations in the manifold layer are exclusively utilized during the training phase to compute the alignment loss (, Section 3.3). They are entirely bypassed during real-time inference, thus incurring zero overhead during edge deployment.
- Physical Layer (Spike Sorting): On power-constrained edge devices, we can perform offline updates for and only when severe signal drift is detected. During the inference phase, only low-power online template matching is required to extract the firing activity (). In fact, all trials within a recording week in our dataset share the exact same static and matrices, which further demonstrates the feasibility of deploying our physical layer design on low-power devices.
- Decision Layer (MoE): To mitigate the computational resource consumption introduced by the MoE architecture, the individual expert classifiers were intentionally designed to be highly lightweight. Rather than employing standard self-attention, each expert utilizes only a single-layer Cross-Attention mechanism with a static 1D learnable query vector (Figure 2). This structural simplification effectively reduces the computational complexity from (as seen in standard Transformers) to .
To quantitatively address the power consumption concerns, we evaluated the inference Floating Point Operations (FLOPs) and CPU latency per trial for LNDN under varying tracked neuron counts (). In our dataset, valid neuron counts strictly ranged between 46 and 68 per session.
| Tracked Neurons () | Total Parameters | Inference FLOPs | CPU Latency (ms/trial) |
|---|---|---|---|
| 50 | 278,892 | 15.47 M | 2.16 ms |
| 100 | 278,892 | 30.69 M | 2.17 ms |
| 200 | 278,892 | 61.13 M | 2.63 ms |
These results confirm that LNDN maintains a modest computational footprint suitable for real-time edge processing.We will include these efficiency metrics in the revised Appendix.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 2/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper targets representational drift in chronic, invasive olfactory-bulb (OB) brain-computer interfaces, where adult neurogenesis and respiration-coupled electrode micro-motion make recorded odor codes decorrelate over weeks, and where biological sensory adaptation forces a "small-sample, high-dimensional" (SSHD) data regime.
The authors propose LNDN, a tracking-free decoder with three stages: (1) a physical level that builds per-unit spatiotemporal triplets (firing PSTH + mean spike waveform + estimated 2D position), projects them, and uses a differentiable dynamic gate to decouple invariant physical identity from transient firing states; (2) a decision level of a Mixture-of-Experts cross-attention module with soft-voting over experts; and (3) a manifold level that aligns latent geometry across sessions via Adaptive Batch Normalization (first-order moment alignment using target-session statistics), second-order correlation alignment (Deep CORAL), and a supervised contrastive loss.
The system is trained only on Weeks 1–4 of a 12-week, 9-mouse, 4-odor dataset and evaluated on the unseen Weeks 5–12. The paper reports 83.67% mean accuracy (vs CEBRA 78.81% and weaker static/temporal/foundation baselines), a stepwise ablation showing the physical-level block contributes the largest single gain (+17.58 pp, 59.24→76.82%), and a drift-quantification analysis (Week-1→Week-8 R² falling from 0.916 to 0.096).
Strengths and weaknesses
Quality (soundness). The biological motivation is sound and the experimental scaffolding (3 seeds × 9 mice, full hyperparameter table in App. B, drift quantification in §5.1) is more careful than is typical for this application. However, the central quantitative claims are not adequately supported.
(i) No significance testing is reported anywhere. Table 1's headline — 83.67% ± 0.1644 (SD) vs CEBRA 78.81% ± 0.1990 — has a 4.86 pp gap that sits inside both marginal standard deviations (the gap is ~0.25–0.30× the reported SDs), yet the paper reports no p-values, confidence intervals, paired/non-parametric tests, or mixed-effects model. The abstract's "significantly outperforming" is therefore unsupported by any reported test.
Field-standard practice for animal-level decoding uses paired Wilcoxon / linear mixed-effects (subject random, elapsed-weeks fixed) and bootstrap CIs — and the paper's own baselines establish this bar. CEBRA substantiates superiority with one-way ANOVA + post-hoc Tukey HSD (e.g., F(3,396)=278.31, p=3.95e-97), one-sided paired t-tests (p=5.99e-5; p=0.024), and Wilcoxon signed-rank (p=0.0341; p=0.0005). ADAN reports that even a "small, about 6%" gain "is statistically significant (one-way ANOVA with Tukey's test, p < 0.01)". amLDS plots 95% posterior CIs + s.e.m. across seeds and 10-fold CV. Against this bar, reporting only mean ± SD is below standard.
The ablation deltas (+SD = +0.74 pp; +TS = +2.74 pp) are even smaller relative to ~0.15–0.20 SD and equally untested. I weight in the authors' favor that a paired analysis could be favorable — because between-mouse variance cancels in a paired/mixed-effects design, the gain could reach significance even with the large group-level SDs (e.g., a sign test of 8/9 per-mouse wins → p≈0.039) if the methods co-vary across mice. That evidence is simply not in the submission, so the claim is unsupported as reported (a blocking-unless-rebutted gap), not provably false.
(ii) The "recalibration-free / set-and-forget / zero-shot" framing is technically inaccurate. AdaBN (Eq. 9, "test-time transductive AdaBN" in Fig. 2) updates batch-norm mean/variance using target test-session data. The AdaBN paper's Algorithm 1 computes "the mean and variance of the target domain: μ^t_j = E(x^t_j), σ^t_j = √Var(x^t_j)" and §4.3.2 explicitly studies "how many target images is necessary to obtain stable statistics".
This is unsupervised transductive test-time adaptation: label-free, but it does consume target-domain statistics and requires batching a session of unlabeled future data, so it is not strictly zero-shot/streaming — LNDN cannot decode the first trial of a new week without look-ahead statistics. By contrast, true zero-target-data inference is achievable by methods LNDN omits (see Significance table). LNDN's transductive AdaBN therefore does not deliver the "set-and-forget" property these methods do, making the label inaccurate rather than merely loose.
(iii) The baseline comparison is confounded by input asymmetry. LNDN consumes firing+waveform+position over all units, whereas all baselines (CEBRA, POYO, SVM/RF/LDA/XGBoost, LSTM/Transformer/RNN) receive only the manually-tracked "common-units" firing matrix (App. A.4) — strictly less information.
POYO scoring ~50% (4-class chance = 25%) most plausibly reflects mis-application of a sparse-spike-tokenization, large-pretraining architecture to a tiny pre-binned SSHD dataset, so the paper's use of POYO's failure to argue "capacity cannot help" over-reaches. The "MLP (Base)" ablation at 59.24% (multi-modal-ish flattened input) vs static baselines at 67–77% further confounds architecture with input modality.
(iv) The drift quantification (§5.1, Fig. 3) is circular. It is computed on the same manually-tracked units that feed the baselines, so if those units are as decorrelated as claimed (R²=0.096), the baselines' "stable" inputs are themselves drifted — partly explaining low baseline scores independent of architecture.
Reproducibility scaffolding is otherwise good, but no per-mouse / per-week breakdown is given to inspect whether the mean is outlier-driven, and the hyperparameter-selection protocol (a Weeks-1–4-only validation split for λ1=0.5, λ2=0.2, dropout, #experts, dims) is not stated, leaving a residual test-week leakage risk unruled-out (App. B).
Clarity (presentation). The paper is well-organized and readable: the problem framing, the three-level methodology, and the stepwise ablation narrative are easy to follow, and Appendices B/C give reproducible hyperparameters and ablation-variant definitions, which supports a Clarity score above the soundness score. The notation in Eqs. 1–14 is coherent and Tables 1/2 are legible.
The defects are minor and do not impede understanding: Figs. 1(c)/2 label all three experts "Experts 1 (q1/q2/q3)" (an apparent typo — should be Expert 1/2/3); App. C refers to "Section 6.3" where §5.3 is meant; the supervised contrastive loss (Eq. 11) is the canonical SupCon form but is not attributed to its origin (uncredited, a Clarity/attribution defect — see Originality); and several acronyms are introduced tersely. These accumulate but none obscure the method.
Significance. The problem is real and under-served — most drift/stabilization work targets motor cortex, and chronic olfactory decoding under the SSHD regime is a genuinely useful setting (§1). The multi-modal physical-identity decoupling (waveform+position+firing with dynamic gating, tracking-free) is a sensible and somewhat distinctive design, and the ablation shows the physical-level block carries the largest single gain (+17.58 pp).
But the demonstrated significance is curtailed on three fronts. First, the inflated claims (significance, zero-shot) above mean the headline contributions are not established as stated. Second, the evaluation is narrow: a single 4-odor saturated-vapor discrimination, one probe type (Symbionics HZ-32U-02), one lab, n=9, with no held-out odor identities, no concentration variation, and no second probe/site — so the abstract/impact framing of a "scalable set-and-forget solution for invasive BCI" extrapolates far beyond the evidence (only partially hedged in §6). Third, and most consequentially for impact, the strongest modern competitors are omitted from both the related work and the baseline table, including methods that are stricter on LNDN's own claimed "recalibration-free" axis.
On the axis the paper foregrounds — capability under zero/low target data — LNDN compares unfavorably to several uncited methods:
| Method | Test-time requirement (target data) | Demonstrated capability on the claimed axis | Same domain as LNDN? | Benchmarked by LNDN? |
|---|---|---|---|---|
| LNDN (this paper) | Transductive — needs a batch of unlabeled target-week data for AdaBN stats | 83.67% mean over Weeks 5–12 (no significance test) | OB / odor / chronic drift | — |
| amLDS (the paper's own ref [20]) | Few-shot unsupervised (~2-trial brief target calibration) | ~76%±3% at ~10% training data vs target-only ~60%±8% (sample-efficient low-data alignment) | Yes — mouse OB / odor / M-T cell / across-animal | No (cited, never benchmarked) |
| CAPTIVATE | True zero-shot — no target look-ahead, no target stats, no test labels | Generalizes to completely unseen sessions (up to 8 days) | Motor (transferable mechanism) | No |
| Flexible-regulation plug-and-play | True zero-shot — no test-time adaptation/look-ahead | 87.43% over a 4-week plug-and-play span | Motor / human (transferable mechanism) | No |
| SPINT (NeurIPS 2025) | Gradient-free few-shot — zero test labels, zero param updates | NoMAD+WF reaches R²≈0.99/0.91/1.03 on FALCON | Motor | No |
The omission of amLDS is the single most damaging gap: it is the manuscript's own cited ref [20], operates in the identical setting (mouse OB / odor / mitral-tufted-cell / long-term drift), is sample-efficient (~2-trial alignment, matching LNDN's SSHD regime), and is plausibly stronger than LNDN in the low-data regime this paper foregrounds. The task-difference argument that might excuse omitting open-ended competitors does not apply — amLDS solves the same task on the same kind of data.
CAPTIVATE and flexible-regulation are stricter than LNDN on its own headline axis (genuinely zero-target), and SPINT is gradient-free, so these are strong real competitors, not strawmen. Beyond these, NoMAD (LFADS + KL distribution alignment), ADAN (adversarial residual matching, ref [30]), TCLA (task-conditioned MMD), and RPNT (pretrained transformer) round out the unbenchmarked field.
Originality. The four alignment mechanisms are each standard, pre-existing techniques: AdaBN; Deep CORAL / CORAL (the paper's ref [35]); MoE soft-voting (Shazeer and the MoE survey both state MoE is a "three-decade-old technology", Jacobs 1991; Jordan & Jacobs 1994); and supervised/latent contrastive learning (the SupCon loss in Eq. 11 is verbatim from Khosla et al., and is uncredited).
Critically, the AdaBN+CORAL pairing is not new — the AdaBN paper itself proposes it: §4.2.1 states "since our method is complementary to other methods, we can simply apply CORAL on the top of AdaBN ... this simple combination exhibits 0.5% increase in performance," and it reports explicit "AdaBN + CORAL" rows in Table 1 (Office-31) and Table 2. So the first-order (AdaBN) + second-order (CORAL) moment-alignment stack that LNDN frames as a manifold-level contribution is essentially a published 2017 baseline combination.
The defensible novelty is therefore the integration plus the application to olfactory chronic drift and the multi-modal physical-identity decoupling — incremental and real — but the manuscript frames the alignment machinery as fundamental ("introduces", "is constructed"), which over-states.
Two further points harden the reject side without changing the score. First, the missing competitor amLDS is not merely uncited-as-baseline but fully applicable and plausibly superior in the low-data regime (~76%±3% vs target-only ~60%±8% at ~10% data), so its omission reads as an avoidance of the single nearest author-cited competitor — the strongest reviewer leverage. Second, the "zero-shot / recalibration-free" claim is affirmatively inaccurate because LNDN's AdaBN is transductive, while CAPTIVATE / flexible-regulation are the missing honest baselines that are genuinely zero-target.
Finally, the manuscript's own errors compound the originality/attribution picture: ref [26] (POYO) cites arXiv:2311.00423, which is a different paper ("LLMRec"); the correct POYO is arXiv:2310.16046; and Eq. 11's SupCon is uncredited.
Questions
-
Significance testing. Please provide per-mouse (and ideally per-week) paired comparisons of LNDN vs each baseline — paired Wilcoxon signed-rank and/or a linear mixed-effects model (subject as random effect, elapsed weeks as fixed) — with effect sizes and bootstrap 95% CIs, and show the LNDN>CEBRA gain is not concentrated in a small subset of mice/weeks.
-
"Recalibration-free / zero-shot" claim is inaccurate. LNDN's AdaBN is test-time transductive: it updates batch-norm statistics from the target session's own data (Eq. 9; "test-time transductive AdaBN" in Fig. 2), so decoding a new week requires first accumulating a batch of future target-session data. That is incompatible with a "zero-shot / set-and-forget" label — the method is label-free but not target-data-free, and it cannot decode the first trial of a new week without look-ahead statistics.
The honest comparison points are true zero-target methods — CAPTIVATE (generalizes to completely unseen sessions with no target look-ahead/statistics/labels) and the flexible-regulation plug-and-play decoder (runs on held-out days with no test-time adaptation) — which are the missing baselines that actually meet the property LNDN claims.
Questions: does AdaBN require a batch of unlabeled target-week data before decoding (and how large)? Were any hyperparameters (λ1, λ2, dropout, #experts, dims) or BN statistics selected using Weeks 5–12? Please (a) report a strictly frozen end-to-end variant (no target-session statistics at test) and its accuracy, (b) benchmark against a true zero-target baseline (CAPTIVATE or flexible-regulation), and (c) confirm hyperparameters were chosen on a Weeks-1–4-only validation split.
-
Baseline fairness. Can you (a) provide an LNDN ablation restricted to the same common-units firing-only input the baselines receive, to separate architecture from input-modality advantage, and (b) justify/repair the POYO and CEBRA configurations (e.g., POYO via its native spike tokenization rather than pre-binned tracked matrices)?
-
Head-to-head vs amLDS — the closest competitor you yourself cite. Why is the single most directly comparable prior work — amLDS (Herrero-Vidal, Rinberg & Savin, NeurIPS 2021), your own ref [20] — cited but omitted from the baseline table, when it operates in the identical setting (same mouse olfactory-bulb / odor / mitral-tufted-cell / long-term-drift context) and is fully applicable here?
This omission is the most consequential gap in the evaluation: amLDS is sample-efficient — it aligns sessions from only ~2 trials, matching LNDN's own SSHD/few-trial regime — and is plausibly stronger than LNDN in the low-data regime that this paper foregrounds, since amLDS's probabilistic manifold alignment reaches ~76%±3% at 10% training data where target-only decoding sits at ~60%±8%, whereas LNDN's supervised-contrastive objective is large-batch-dependent and disadvantaged under SSHD. The task-difference argument that excuses omitting open-ended competitors does not apply here — amLDS solves the same task on the same kind of data.
Beyond amLDS, the true zero-target-data methods that actually satisfy the "recalibration-free" property LNDN claims (CAPTIVATE and the flexible-regulation plug-and-play decoder; plus SPINT, gradient-free few-shot; NoMAD, ADAN, TCLA, RPNT) are also neither discussed nor benchmarked. Please add at least amLDS and one true-zero-target method (CAPTIVATE or flexible-regulation) as baselines.
Limitations
Partially addressed. The Discussion honestly notes dependence on an initial spike-sorting pipeline, the single 4-odor task, and the compute overhead of MoE + CORAL. However, the two most consequential limitations are not acknowledged: (a) that AdaBN's transductive use of target-session statistics undercuts the central "recalibration-free / zero-shot" claim, and (b) that the headline improvement is reported without any significance test under n=9 with large SDs.
The NeurIPS checklist answer to Q7 ("statistical significance: Yes — Mean ± SD across 9 mice") is misleading, since reporting an SD is not a significance test.
Formatting concerns
None.
5 comments
Response to Q4、W4: Comparison Experiments with Domain Baselines (amLDS, SPINT, CAPTIVATE)
We are grateful to the reviewer for highlighting the importance of evaluating LNDN against domain-relevant baselines (amLDS, SPINT, and CAPTIVATE). We have incorporated head-to-head evaluations against these models:
- amLDS (Few-Shot Benchmark): The training pipeline of amLDS is kept identical to that of LNDN. Given the recalibration requirement of amLDS during inference, we perform independent recalibration and testing on a weekly basis, where 10% labeled trials from each target week are adopted for recalibration. The hyperparameters (latent dimension = 8, EM iterations = 10) are selected via training on Weeks 1–3 data and validation on Week 4 data, consistent with our universal hyperparameter screening strategy. For the configuration of EM iterations, we initially followed the original amLDS implementation by setting the convergence tolerance to with a maximum iteration number of 50. Nevertheless, this configuration yielded severely degraded decoding performance (see the amLDS_convergence group in the corresponding table). Accordingly, we treated EM iteration count as a tunable hyperparameter and determined the optimal value of 10 through formal validation screening.
- SPINT (Few-Shot Benchmark): The original SPINT framework is designed for continuous movement decoding. To adapt it to our discrete odor classification task, we modified the original output heads into scalar logit branches, with each odor category assigned a corresponding learnable query vector. CrossEntropyLoss is utilized as the objective function to fit the discrete classification task, while all remaining network architectures strictly follow the native implementation of SPINT without extra modifications. For fair comparison, we adopt the same weekly calibration strategy as amLDS, using 10% trials(unlabeled) from each target week during the calibration phase.
- CAPTIVATE (Zero-Target Benchmark): We reproduced CAPTIVATE strictly following the network architecture and training pipeline detailed in its original paper. The backbone of the model consists of a GRU-based neuron locator, a sequential variational autoencoder, and a downstream classifier as proposed in the original work. We adopted the six perturbation types and loss functions specified in the paper throughout training.
| Model | Category / Target Supervision | Accuracy (Mean SD) | Precision (Mean SD) | F1-Score (Mean SD) |
|---|---|---|---|---|
| LNDN (Ours) | Transductive Test-Time Adaptation | |||
| SPINT | Few-Shot (Label-guided) | |||
| amLDS (EM=10) | Few-Shot (10% Labeled Target Data) | |||
| amLDS (Convergence) | Few-Shot (10% Labeled Target Data) | |||
| CAPTIVATE | Zero-Target (Self-Supervised) |
All quantitative metrics consistently verify the effectiveness of LNDN. We will integrate all the above baseline comparison results(best) into the main text of the revised manuscript.
Response to Minor Comments: Figure Labeling Clarification and Citation Issue Rectification
Author Response:
We sincerely thank the reviewer for carefully reading the manuscript and pointing out these details.
We would like to clarify that the notations (q1/q2/q3) in Figures 1(c) and 2 were originally intended to denote the dedicated learnable query vectors () associated with each respective expert in the Mixture-of-Experts (MoE) cross-attention module (as defined in Section 3.3). Comprehensive checks and revisions will be implemented for all citation concerns addressed in your review comments within the revised manuscript.
Response to Q3、W3: Input Modality Ablation and Baseline Configuration Fairness
We thank the reviewer for the comments on input fairness. Regarding the discrepancy raised in Weakness (iii): the "MLP (base)" ablation condition achieves an accuracy of 59.24%, while the static baselines reach 67–77%. This gap is primarily attributed to the fact that the MLP (base) ablation experiment employs the same neural activity data as LNDN, without any cross-session neuronal tracking or alignment.
Without cross-session neuronal tracking and alignment, baseline models suffer from severe overfitting when fed with mixed and unordered neural activity signals. Our model is specifically designed to address this limitation: it leverages neuronal identity information output from spike sorting to enable decoding from neuronal populations of arbitrary size and ordering.
(a) To further address your question and verify whether LNDN’s superior performance stems from access to additional input information, we have supplemented the following comparison groups:
- Baselines (Full Data): All baselines (except POYO) use the same input as LNDN: firing matrices are zero-padded to capacity, with waveform and position vectors prepended to prevent temporal model (e.g., RNN/LSTM) hidden state collapse. Since native POYO requires continuous spike tokens and cannot accommodate auxiliary physical features, it is evaluated on its native raw spike tokens for comparison.
- LNDN (CU Data): LNDN restricted to Common Units, utilizing both activity and physical features.
- LNDN (CU Activity Only): LNDN restricted strictly to Common Unit firing rates (identical input to standard baselines).
| Model Variant | Accuracy (Mean SD) | Precision (Mean SD) | F1-Score (Mean SD) |
|---|---|---|---|
| LNDN (Full Data) | |||
| SVM (Full Data) | |||
| CEBRA (Full Data) | |||
| LDA (Full Data) | |||
| RF (Full Data) | |||
| XGBoost (Full Data) | |||
| LSTM (Full Data) | |||
| Transformer (Full Data) | |||
| RNN (Full Data) | |||
| POYO(Scratch) | |||
| POYO(Pretrained) | |||
| LNDN (CU Data) | |||
| LNDN (CU Activity Only) |
The results demonstrate that standard baselines suffer severe performance degradation (falling below 50%) when exposed to the raw, un-tracked cross-week data due to severe noise overfitting. For this reason, we utilize cross-week aligned neurons specifically to ensure baseline models can be fairly compared against our method at their best achievable performance.
(b) We apologize for the insufficient clarity in our manuscript regarding the input data configuration for POYO. In fact, we evaluated POYO strictly using its native spike tokenization setup. We attribute the underperformance of POYO primarily to the limited scale of the olfactory dataset. Converting individual spike events into discrete tokens, the core paradigm of POYO, is prone to overfitting on small datasets; in contrast, the bin-based tokenization approach adopted by SPINT(in Q4) achieves relatively better performance in this low-data regime. The original POYO model was trained on nearly 29,453 units to construct a stable global attention map over discrete spike tokens. Furthermore, there exists a substantial discrepancy between our target brain region and the motor cortex that POYO was designed for. As explicitly stated in the POYO work, all data in its multi-laboratory dataset were collected from the motor cortex. This mismatch in brain regions is likely a key reason for its limited applicability to our olfactory decoding task.
We will supplement the above baseline comparisons in the revised manuscript and specify the data input format adopted by POYO.
Response to Q2、W2: Conceptual Clarification on "Zero-Shot" Claim and AdaBN Batch Dynamics
We sincerely thank the reviewer for correcting the terminology in our work and for the constructive feedback. We have conducted supplementary experiments and detailed clarifications to fully address your concerns. Following your suggestion, given the design of AdaBN in our framework, we will revise the description from "recalibration-free / zero-shot" to transductive test-time adaptation (TTA) in the revised manuscript. For all models, hyperparameter tuning was uniformly performed by training on data from the first three weeks of each mouse and validating on Week 4 data.
We provide detailed responses to your specific questions below:
- During hyperparameter tuning, we applied a consistent batch size to both the training and validation sets, and the final optimal batch size was determined to be 32. Accordingly, the main experimental results reported in our original manuscript reflect the performance of AdaBN with a batch size of 32. In response to your question regarding the required target data scale for AdaBN, we carried out supplementary experiments on the test set, including a strictly frozen end-to-end variant without AdaBN, as well as AdaBN configurations with batch sizes of 4, 8, 16, and 32. We obtained several noteworthy findings, summarized in the table below:
| AdaBN Batch Size | Accuracy (Mean SD) | Precision (Mean SD) | F1-Score (Mean SD) |
|---|---|---|---|
| No AdaBN | |||
| (Default) |
We have confirmed that the data loading order of the test set matches the original trial sequence in the experiment, and the odor presentation order across trials was randomized. This rules out the possibility that performance improvements stem from balanced class representation within each batch. We attribute this pattern to sensory adaptation in olfactory bulb neurons. A batch of 32 trials spans a relatively long time window, and batch statistics computed over such a tens-of-minutes timescale may conflate neural drift driven by sensory adaptation. In contrast, the shorter 4-trial window provides a background baseline with finer temporal resolution, preventing the model from misinterpreting "attenuated neural responses due to sensory adaptation" as a change in odor category.
- The comparative experiments with the zero-target baseline will be presented together with the amLDS results in "Response to Q4".
- For all models, hyperparameter tuning was uniformly conducted using Weeks 1–3 data for training and Week 4 data for validation per mouse. The results across different AdaBN batch sizes also confirm that our hyperparameter tuning process did not leverage any data from Weeks 5–12.
Experiments on AdaBN will be supplemented in the appendix of the revised manuscript.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
We sincerely thank you for recognizing the importance of our research and for your constructive guidance in the Meta Review. We have now responded to all the preliminary comments raised by the reviewers and provided detailed supplementary experiments and analyses. To address your specific concerns, we provide the following detailed clarifications:
① "The paper offers relatively little motivation about why their approach is appropriate."
In our "Response to Q3, Q4, Q8: Lack of Theoretical Motivation and Biological Incorporation" to Reviewer 3gev, we thoroughly clarified how our proposed tri-level alignment strategy maps to and resolves the specific biological challenges inherent in long-term olfactory recordings:
② "The reviewers raised several q uestions related to the methodology and comparisons to baselines."
③ Fairness of Baseline Settings:
We noted that two reviewers raised concerns regarding the baseline configurations. In fact, the chaotic and unordered nature of neural information in cross-session decoding without neuron tracking has always been a critical challenge in the field. Our initial decision to provide baseline models with cross-session tracked and aligned neural data was explicitly intended to allow all comparative models to achieve their optimal performance, preventing them from suffering severe overfitting due to unordered input data. In our "Response to Q1: Unfair Baseline Comparisons" to Reviewer 3gev, we comprehensively demonstrated that if tracking is omitted and all baseline models are fed the exact same raw data inputs as LNDN, they suffer from a severe degradation in classification accuracy.
④ How Our Model Outperforms Current Models:
Beyond its decoding accuracy, our model possesses several objective structural strengths: