potentialpaper

MotorSense: A Video-EMG Dataset of Motoric Representations for Action Understanding

Eadom T Dessalene, Michael Maynord, Amir Hossein Shahidzadeh, Botao He, Yasamin Tabatabaee, Ruoshi Liu, Ruohan Gao, Paul Pu Liang, Yiannis Aloimonos

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

Abstract. Computer vision models learn hand action only from its visual consequences, without access to the underlying embodied motor signals. We address this absence with MotorSense - the first large-scale paired egocentric video and surface electromyography (EMG) dataset. MotorSense pairs bimanual EMG bands with egocentric video and yields synchronized video, bimanual EMG and IMU, and audio across 100100 hours of unscripted manipulation. EMG offers a powerful scalable alternative to manual annotation: it captures finger movement, hand configuration, and the forces exerted between hand and environment as a dense signal free of occlusion and labeler bias, whereas manual annotation is costly, subjective, and unreliable under occlusion. We use MotorSense to learn sensorimotor alignment, producing an organization of action that is shared across the visual and motoric spaces, through cross-modal pre-training between video and EMG. The resultant vision models are then transferred to downstream tasks that benefit from sensorimotor alignment: in this case, action recognition, 3D hand reconstruction, and 3D contact reconstruction. We further demonstrate a generative application in which EMG motor signals are used to condition a video diffusion model, yielding videos of fine-grained hand manipulation. Across four action-centric computer vision tasks and eight popular video datasets, we demonstrate that sensorimotor alignment provides a stronger foundation for visual representation learning than conventional self-supervised learning methods over video, outperforming every baseline across all tasks and datasets evaluated.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
5 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]—[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 5 reviews · OpenReview

Updated 25 Nov 2026, 03:43 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

This work introduces MOTORSENSE, a paired egocentric video and bimanual EMG/IMU dataset, along with discrete motor codes used for visual pretraining and video generation. The paper received mixed reviews (1 accept and 2 borderline rejects). Reviewers found the embodied supervision signal, dataset, and downstream gains promising, but raised concerns about: (i) only four participants and no held-out-subject evaluation, (ii) missing matched visual-only and hand-pose baselines needed to isolate the value of EMG, (iii) incomplete modality and objective ablations, (iv) largely qualitative motor-code and generation analyses, and (v) insufficient privacy, consent, and dataset-governance documentation.

The initial reviews and scores place the paper in a borderline category where clarification about cross-subject generalization, controlled baselines, and human-subject safeguards can help mitigate major weaknesses and address reviewer comments.

Post-rebuttal, many of these concerns were addressed, and the reviewers all noted borderline-accept scores. While the contributions are clearer, there are still lingering concerns over the limited participant diversity, statistical analysis, and lack of evaluation for downstream action recognition or 3D reconstruction tasks. Taking the manuscript, reviews, and rebuttal into account, the strengths outweigh the weaknesses, and the AC concurs with the reviewers and recommends acceptance.

The authors are strongly encouraged to incorporate the information from the rebuttal into the final version for completeness, particularly those noted in the ethics reviews and response.

Final justification

Noted in the meta-review.

Strengths outweigh weaknesses, and the rebuttal did a good job addressing most concerns.

Area Chair 3Kje · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

This work introduces MOTORSENSE, a paired egocentric video and bimanual EMG/IMU dataset, along with discrete motor codes used for visual pretraining and video generation. The paper received mixed reviews (1 accept and 2 borderline rejects). Reviewers found the embodied supervision signal, dataset, and downstream gains promising, but raised concerns about: (i) only four participants and no held-out-subject evaluation, (ii) missing matched visual-only and hand-pose baselines needed to isolate the value of EMG, (iii) incomplete modality and objective ablations, (iv) largely qualitative motor-code and generation analyses, and (v) insufficient privacy, consent, and dataset-governance documentation.

The initial reviews and scores place the paper in a borderline category where clarification about cross-subject generalization, controlled baselines, and human-subject safeguards can help mitigate major weaknesses and address reviewer comments.

Post-rebuttal, many of these concerns were addressed, and the reviewers all noted borderline-accept scores. While the contributions are clearer, there are still lingering concerns over the limited participant diversity, statistical analysis, and lack of evaluation for downstream action recognition or 3D reconstruction tasks. Taking the manuscript, reviews, and rebuttal into account, the strengths outweigh the weaknesses, and the AC concurs with the reviewers and recommends acceptance.

The authors are strongly encouraged to incorporate the information from the rebuttal into the final version for completeness, particularly those noted in the ethics reviews and response.

Final justification

Noted in the meta-review.

Strengths outweigh weaknesses, and the rebuttal did a good job addressing most concerns.

Reviewer TotjOpenReview ↗
Rating
5/6
Confidence
3/5
Quality
4/4
Clarity
4/4
Significance
4/4
Originality
4/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper introduces how EMG & IMU features could help video action understanding task, they introduced MotorCOdes which is used as to be infused to action understanding task (action reconstruction, hand reconstruction, and video reconstruction), this paper also introduces a new dataset which pair EMG data with egocentric video.

Strengths and weaknesses

Strengths:

  • This paper is well written and easy to understand
  • Strong, consistent downstream results across diverse benchmarks and tasks
  • Showing how EMG+IMU data actually correlate to how human actually works, i.e in Figure 1 shows when hands
  • To solve the annotation cost problem, this paper introduces self-supervised representations, Motorcodes are learned entirely from raw EMG via VQ-VAE, and the downstream gains come without any human annotation of the pre-training data.
  • The same motor codes serve both as a discriminative pre-training target and as a generative control signal. Demonstrating that one learned representation transfers across recognition, reconstruction, and generation

Weaknesses:

  • Motor-code analysis is qualitative. The "codes correlate with action semantics" claim rests on a t-SNE plot. No quantitative measure (clustering purity, MI, or a code→action linear probe)
  • Incomplete isolation of the EMG contribution. The IMU ablation helps, but there is no continued video-only self-supervised pre-training baseline on motorsense. Without it, "motor codes help" is partly confounded with "more in-domain egocentric video helps." an ablation on reconstruction would be better since IMU help with the position a lot.
Questions
  • "we use a per-vertex threshold of 10% as opposed to 5%", mentioned in page 8, Why the 10% ARCTIC threshold? What are the numbers at the standard 5%?
  • Any sensitivity analysis for codebook size (N=64), code rate (64/s), and window length (1.5s)?
Limitations

yes

Formatting concerns

none

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the thoughtful and positive assessment of our work. We appreciate the observation that motor codes provide a useful embodied signal for many downstream tasks in computer vision. The reviewer’s main concerns focus on whether the semantic structure of the codes can be demonstrated quantitatively and whether the gains can be separated from the effect of additional in-domain video pre-training. We have addressed both points through new experiments.

  1. Quantitative motor-code analysis

We agree that the original t-SNE visualization was insufficient. We fit a K-means clustering model over the labeled motor-code representations, with the number of clusters set by the number of actions under evaluation. For each value of kk, we select the kk most frequent annotated actions and fit kk clusters over the frozen motor-code representations without using labels. We then label each cluster using the ground-truth label of the sample closest to its centroid and assign that label to the remaining samples in the cluster. Thus, labels are used only to name each learned cluster, using one labeled exemplar per cluster. The results are encouraging given that only one labeled exemplar per cluster is used.

kVerbNounAction21.0001.0001.00030.6451.0000.64540.7110.7110.52650.7210.6510.51260.6880.5420.43870.7170.4910.45380.6840.4390.42190.6500.4500.417100.5400.5710.429\begin{array}{cccc} \hline \text{k} & \text{Verb} & \text{Noun} & \text{Action} \\\\ \hline 2 & 1.000 & 1.000 & 1.000 \\\\ 3 & 0.645 & 1.000 & 0.645 \\\\ 4 & 0.711 & 0.711 & 0.526 \\\\ 5 & 0.721 & 0.651 & 0.512 \\\\ 6 & 0.688 & 0.542 & 0.438 \\\\ 7 & 0.717 & 0.491 & 0.453 \\\\ 8 & 0.684 & 0.439 & 0.421 \\\\ 9 & 0.650 & 0.450 & 0.417 \\\\ 10 & 0.540 & 0.571 & 0.429 \\\\ \hline \end{array}
  1. Representation ablations

We agree that an in-domain visual baseline is necessary to distinguish the value of motor-code supervision from the value of simply continuing pre-training on egocentric video.

We therefore train CVRL using the same MOTORSENSE clips, Hiera backbone, K400 initialization, hand-focused cropping, and downstream fine-tuning protocol used for motor-code pre-training. We also expand the ablation to compare raw continuous EMG, discrete EMG-only codes, histogram aggregation, Aria MPS hand-pose supervision, and alternative EMG+IMU objectives.

Pre-training configurationEPIC verbEPIC nounMeccano actionK400 initialization only41.6515.1226.42Vision-only (CVRL) [1]41.0119.3128.99Pose (no VQ-VAE)46.9220.1031.50Pose (VQ-VAE + histogram)43.2915.9026.05EMG-only (raw)42.2314.9926.62EMG-only (VQ-VAE)46.0116.3827.29EMG-only (VQ-VAE + histogram)48.5920.9933.36EMG + IMU (no VQ-VAE)45.8619.7231.76EMG + IMU (VQ-VAE)49.2020.2236.15EMG + IMU (ours)52.6422.2337.32\begin{array}{lccc} \hline \text{Pre-training configuration} & \text{EPIC verb} & \text{EPIC noun} & \text{Meccano action} \\\\ \hline \text{K400 initialization only} & 41.65 & 15.12 & 26.42 \\\\ \text{Vision-only (CVRL) [1]} & 41.01 & 19.31 & 28.99 \\\\ \text{Pose (no VQ-VAE)} & 46.92 & 20.10 & 31.50 \\\\ \text{Pose (VQ-VAE + histogram)} & 43.29 & 15.90 & 26.05 \\\\ \text{EMG-only (raw)} & 42.23 & 14.99 & 26.62 \\\\ \text{EMG-only (VQ-VAE)} & 46.01 & 16.38 & 27.29 \\\\ \text{EMG-only (VQ-VAE + histogram)} & 48.59 & 20.99 & 33.36 \\\\ \text{EMG + IMU (no VQ-VAE)} & 45.86 & 19.72 & 31.76 \\\\ \text{EMG + IMU (VQ-VAE)} & 49.20 & 20.22 & 36.15 \\\\ \text{EMG + IMU (ours)} & \mathbf{52.64} & \mathbf{22.23} & \mathbf{37.32} \\\\ \hline \end{array}
\begin{array}{llcc} \hline \text{Method} & \text{Pre-training} & \text{MPJPE}\downarrow & \text{Success@5\\%}\uparrow \\\\ \hline \text{ARCTIC} & \text{IN} & 25.41 & 50.26 \\\\ \text{PixPro} & \text{IN} & 24.69 & 51.63 \\\\ \text{DenseCL} & \text{COCO + IN} & 27.33 & 48.82 \\\\ \text{SimHand} & \text{100DOH + Ego4D} & 34.94 & 41.90 \\\\ \text{PeCLR} & \text{100DOH + Ego4D} & 28.82 & 45.03 \\\\ \text{DenseCL} & \text{IN + MotorSense (RGB)} & 28.89 & 49.83 \\\\ \text{VICRegL} & \text{IN + MotorSense (RGB)} & 27.81 & 48.10 \\\\ \text{Ours} & \text{IN + MotorSense} & \mathbf{23.59} & \mathbf{55.03} \\\\ \hline \end{array}
  1. Sensitivity to codebook size, code rate, and window length

These experiments are interesting, as it is expected these factors should have a large influence on the performance of the motor code predictor, and therefore downstream impact. Surprisingly, we do not observe this to be the case for codebook size and window length (and observe minor changes varying codes per second). Once all the runs complete we will report them here.

Reviewer aPgrOpenReview ↗
Rating
4/6
Confidence
3/5
Quality
2/4
Clarity
3/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
Major Concern: Data privacy, copyright, and consent
Read review
Summary

The paper introduces MOTORSENSE, a paired egocentric-video and bimanual surface-EMG dataset for hand-object manipulation. The dataset contains 25 hours of unscripted kitchen manipulation recorded with Meta Aria glasses and two wrist-worn EMG/IMU armbands. The authors learn discrete “motor codes” from EMG+IMU using a VQ-VAE, then use these codes in two ways: as privileged supervision for visual pretraining and as a conditioning signal for image-to-video generation of hand-object manipulation. The paper evaluates the learned representations on action recognition across EPIC-Kitchens, Ego-Exo4D, and Meccano, on 3D hand-object reconstruction using ARCTIC, and on video generation over held-out MOTORSENSE recordings.

Strengths and weaknesses
  • Strength — well-motivated embodied supervision signal. EMG is a compelling privileged signal for hand-action understanding because it can capture muscle activity, finger articulation, grasping, and force-related information that may be hidden in video. The VQ-VAE motor-code formulation is a reasonable way to turn low-level EMG into a higher-level supervision target.
  • Strength — useful controlled downstream evaluation. The paper evaluates action recognition, 3D hand-object reconstruction, and video generation. The action-recognition setup is a controlled backbone comparison: Hiera-B and EgoVideo-B are compared before/after motor-code pretraining. Frozen results improve substantially, e.g., Hiera-B 13.11→25.48 on Ego-Exo4D and 26.42→37.32 on Meccano; EgoVideo-B 26.00→35.99 on Ego-Exo4D and 36.59→40.26 on Meccano.
  • Strength — helpful IMU ablation. The IMU-only ablation shows that wrist-motion supervision alone helps less than EMG+IMU motor-code pretraining, supporting the claim that EMG adds useful fine-grained signal beyond coarse wrist motion.
  • Weakness — novelty and scale claims need qualification. The “first large-scale paired egocentric video and surface EMG dataset” claim is too broad. ActionSense is prior video+EMG work in kitchen activities, and it used Myo armbands with 8 dry EMG electrode pairs on each forearm. MOTORSENSE may be larger-duration and more integrated into representation learning, but the claim should be narrowed.
  • Weakness — participant diversity and subject generalization are weak. The dataset has 25 hours but only 4 participants, and validation holds out recordings/environments rather than subjects. This is a major limitation for EMG because user physiology, sensor placement, armband fit, and session effects can strongly change the signal. The appendix also says participants with larger forearms were prioritized because bands slip on slender wrists.
  • Weakness — the necessity of EMG over Aria hand annotations is not established. The paper itself uses Aria MPS to extract camera pose and 3D hand pose/keypoints, and MPS boxes are also used for video-generation evaluation. A key missing baseline is pretraining or conditioning on Aria/MPS hand pose/keypoints instead of EMG motor codes. Without this, it is unclear whether a separate EMG dataset is necessary beyond the hand annotations already available from the Aria pipeline.
  • Weakness — benchmark reporting and comparison scope are incomplete. The action-recognition table is best viewed as a controlled pretraining ablation, not a broad SOTA comparison. The paper does not compare to several recent egocentric/video-language methods it cites. Metric reporting is also incomplete: EPIC-Kitchens reports verb/noun top-1 but not combined action metrics, while EPIC supports verb/noun/action top-k, precision, and recall; Meccano reports only top-1, whereas the challenge expects top-1 and top-5.
  • Weakness — ARCTIC comparison is not fully standard. MPJPE and object-pose success are relevant metrics, but the paper uses a 10% per-vertex threshold instead of 5%, making the success numbers less directly comparable to standard ARCTIC reporting. Table 2 should be framed as a controlled pretraining comparison, not a full hand-object reconstruction SOTA result.
  • Weakness — source of gains is not fully isolated. Several factors remain entangled: EMG vs. IMU, discrete VQ codes vs. continuous EMG regression, extra in-domain pretraining on MOTORSENSE clips, hand-focused cropping, and histogram prediction. Same-data video-only pretraining, continuous-EMG regression, EMG-only codes, IMU-only VQ codes, and MPS hand-pose supervision would make the causal claim stronger.
  • Weakness — motor-code and video-generation analyses are suggestive but limited. The motor-code semantic analysis is mainly a t-SNE from one held-out recording. The video-generation metrics, FVD/LPIPS/PSNR on hand crops, measure visual fidelity but not action correctness, contact, force, or object-state preservation. A pose/keypoint conditioning baseline is also missing.
  • Weakness — dataset governance documentation is insufficient. The dataset includes egocentric RGB, audio, GPS, kitchen environments, EMG, IMU, camera pose, and hand-pose trajectories. The authors answer “Yes” to IRB/equivalent review, but the justification only says EMG is non-invasive and does not clearly state approval/exemption, risk disclosure, consent, compensation, bystander handling, audio/GPS policy, de-identification, licensing, or access restrictions. The checklist also marks “new assets” as N/A despite releasing a dataset and code.
Questions
  • A subject-held-out evaluation seems important for this submission. Please report motor-code discovery, action-recognition transfer, ARCTIC transfer, and video-generation results when test subjects are not seen during training, since the dataset has only 4 participants and EMG signals are likely to be subject- and placement-dependent.
  • A direct Aria/MPS hand-pose baseline would clarify the need for EMG. Since the pipeline already extracts 3D hand pose/keypoints from Aria MPS, please compare motor-code pretraining and video-generation conditioning against MPS hand-pose/keypoint supervision.
  • The source of the representation gains should be isolated more carefully. Please add same-data baselines such as video-only pretraining on MOTORSENSE clips, continuous-EMG regression, EMG-only motor codes, and IMU-only VQ codes.
  • For benchmark completeness, the action-recognition metrics should be expanded. Please report EPIC-Kitchens combined action top-1/top-5 in addition to verb/noun accuracy, and include Meccano top-5 results alongside top-1.
  • The ARCTIC evaluation should be made directly comparable to standard reporting. Please report the standard 5% object-success threshold as well.
  • The dataset release needs a more complete governance statement. Please specify participant consent, compensation, IRB approval/exemption or equivalent review, risk disclosure, bystander handling, audio/GPS release policy, de-identification, licensing, and access restrictions.
Limitations

No. The paper has a short limitations paragraph, but it is not adequate for a human-subject egocentric dataset. It mentions hardware and the small participant count, but does not sufficiently discuss cross-subject generalization, sensor fit, armband slippage, privacy, bystanders, audio/GPS release, dataset access controls, or the availability of Aria/MPS hand-pose annotations as an alternative supervision source.

Final justification

Thank you for the detailed rebuttal. The added held-out-participant evaluation, MPS-pose and same-data RGB baselines, modality and objective ablations, revised ARCTIC metric, and clearer governance documentation substantially address my main concerns and make the technical contribution more convincing. However, important limitations remain, including limited participant diversity, the absence of downstream subject-disjoint evaluation and an IMU-only control, incomplete standard benchmark reporting, and limited semantic evaluation of video generation. I therefore raise my rating to Borderline Accept: the work is now slightly above the acceptance threshold, but the remaining gaps and need for careful claim qualification prevent an outright Accept.

Formatting concerns

The checklist inconsistently marks “new assets” as N/A despite the claimed dataset/code release.

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the detailed assessment and for recognizing the motivation and value of EMG as an embodied supervision signal. The work is stronger in response to this review. We expanded MOTORSENSE from four to ten participants, added direct held-out-participant and cross-domain motor-code prediction results, added several modality and learning objective ablations, introduced quantitative motor-code analysis, and clarified the IRB filed and the human subject details.

  1. Novelty and scale claim

We agree that the original phrase “first large-scale paired egocentric video and surface-EMG dataset” was too broad. MotorSense provides better capture of hand-centric motor signals as well as many other improvements, and to better distinguish our work from ActionSense we briefly mention these in the Related Works and go in depth in the Appendix. We now introduce our work as: "We introduce MotorSense, a 31-hour dataset pairing egocentric video with bimanual surface EMG and IMU during natural, unscripted hand–object manipulation."

  1. Participant diversity and held-out-subject generalization

Since submission, we have collected data from six additional participants, each contributing approximately one hour. The revised dataset therefore contains approximately 31 hours of recordings from ten participants.

Although transfer to EPIC-Kitchens, Ego-Exo4D, Meccano, and ARCTIC provides evidence that the learned visual representations transfer to actions performed by entirely different participants, we agree that this is indirect and does not replace a direct held-out-participant evaluation of motor-code prediction. We therefore now evaluate video-to-motor-code prediction on seen and unseen participants during training.

Evaluation settingKL divergence↓Normalized ℓ1 distance↓Seen participants, cooking0.740.31Unseen participants, cooking0.830.33\begin{array}{lcc} \hline \text{Evaluation setting} & \text{KL divergence}\downarrow & \text{Normalized }\ell_1\text{ distance}\downarrow \\\\ \hline \text{Seen participants, cooking} & 0.74 & 0.31 \\\\ \text{Unseen participants, cooking} & 0.83 & 0.33 \\\\ \hline \end{array}

We additionally evaluate the motor code predictor on unseen participants performing assembly, cleaning, and laundry.

Evaluation domainKL divergence↓Normalized ℓ1 distance↓Cooking0.830.33Assembly0.890.33Cleaning0.860.36Laundry0.910.40\begin{array}{lcc} \hline \text{Evaluation domain} & \text{KL divergence}\downarrow & \text{Normalized }\ell_1\text{ distance}\downarrow \\\\ \hline \text{Cooking} & 0.83 & 0.33 \\\\ \text{Assembly} & 0.89 & 0.33 \\\\ \text{Cleaning} & 0.86 & 0.36 \\\\ \text{Laundry} & 0.91 & 0.40 \\\\ \hline \end{array}

The decrease in performance from activity-domain shift is larger than the decrease from subject shift, particularly for laundry. This suggests that domain breadth is the larger remaining limitation and motivates the collection of a larger, multi-domain dataset. We leave this to future work.

  1. Aria MPS hand-pose baseline and isolation of the representation gains

We agree that an Aria MPS hand-pose baseline is important because it tests whether the improvements require an embodied motor signal or can instead be obtained from automatically estimated hand configuration. We also agree that the original experiments did not completely isolate motor-code supervision from additional in-domain RGB exposure or our motor code formulation.

We therefore expanded the action-recognition ablation to include variants of: vision-only CVRL [1] pre-training on MOTORSENSE clips, Aria MPS pose prediction, EMG-only prediction, and EMG+IMU prediction. All action-recognition ablations use the same Hiera backbone, initialization, MOTORSENSE clips, and hand-focused cropping.

Pre-training configurationEPIC verbEPIC nounMeccano actionK400 initialization only41.6515.1226.42Vision-only (CVRL) [1]41.0119.3128.99Pose (no VQ-VAE)46.9220.1031.50Pose (VQ-VAE + histogram)43.2915.9026.05EMG-only (raw)42.2314.9926.62EMG-only (VQ-VAE)46.0116.3827.29EMG-only (VQ-VAE + histogram)48.5920.9933.36EMG + IMU (no VQ-VAE)45.8619.7231.76EMG + IMU (VQ-VAE)49.2020.2236.15EMG + IMU (ours)52.6422.2337.32\begin{array}{lccc} \hline \text{Pre-training configuration} & \text{EPIC verb} & \text{EPIC noun} & \text{Meccano action} \\\\ \hline \text{K400 initialization only} & 41.65 & 15.12 & 26.42 \\\\ \text{Vision-only (CVRL) [1]} & 41.01 & 19.31 & 28.99 \\\\ \text{Pose (no VQ-VAE)} & 46.92 & 20.10 & 31.50 \\\\ \text{Pose (VQ-VAE + histogram)} & 43.29 & 15.90 & 26.05 \\\\ \text{EMG-only (raw)} & 42.23 & 14.99 & 26.62 \\\\ \text{EMG-only (VQ-VAE)} & 46.01 & 16.38 & 27.29 \\\\ \text{EMG-only (VQ-VAE + histogram)} & 48.59 & 20.99 & 33.36 \\\\ \text{EMG + IMU (no VQ-VAE)} & 45.86 & 19.72 & 31.76 \\\\ \text{EMG + IMU (VQ-VAE)} & 49.20 & 20.22 & 36.15 \\\\ \text{EMG + IMU (ours)} & \mathbf{52.64} & \mathbf{22.23} & \mathbf{37.32} \\\\ \hline \end{array}

The video network did not successfully predict raw EMG signals, and therefore performed poorly in downstream tasks. Discretization addresses this difficulty by making the learning of high-frequency EMG signals more tractable. Furthermore, the aggregation of these discrete codes into a histogram reduces the sensitivity of the model's predictions to precise temporal alignment with the EMG data, which can be difficult due to the frequency gap between the vision input and EMG targets. We also ran experiments using Aria MPS hand pose. We observed that pose supervision is weaker than motor code supervision. This is likely because MPS finger estimates can become noisy under occlusion, when hand-object interaction occurs. Wrist-mounted IMU remains available during visual occlusion and helps represent arm and wrist motion, as well as helps stabilize the network's interpretation of the EMG signals (EMG signals are noisy when the band undergoes jerky movements). All of this analysis is included in the Appendix.

For 3D hand-object reconstruction, we additionally trained DenseCL [3] and VICRegL [2] using only the same MOTORSENSE RGB frames before fine-tuning on ARCTIC.

\begin{array}{llcc} \hline \text{Method} & \text{Pre-training} & \text{MPJPE}\downarrow & \text{Success@5\\%}\uparrow \\\\ \hline \text{ARCTIC} & \text{IN} & 25.41 & 50.26 \\\\ \text{PixPro} & \text{IN} & 24.69 & 51.63 \\\\ \text{DenseCL} & \text{COCO + IN} & 27.33 & 48.82 \\\\ \text{SimHand} & \text{100DOH + Ego4D} & 34.94 & 41.90 \\\\ \text{PeCLR} & \text{100DOH + Ego4D} & 28.82 & 45.03 \\\\ \text{DenseCL} & \text{IN + MotorSense (RGB)} & 28.89 & 49.83 \\\\ \text{VICRegL} & \text{IN + MotorSense (RGB)} & 27.81 & 48.10 \\\\ \text{Ours} & \text{IN + MotorSense} & \mathbf{23.59} & \mathbf{55.03} \\\\ \hline \end{array}

Motor-code supervision obtains the best MPJPE and Success@5% in the expanded comparison, whereas DenseCL and VICRegL trained on the same RGB frames perform worse than several existing baselines. Similar results hold for the CVRL baseline in action recognition. These results address your concerns the improvements arise merely from additional in-domain visual exposure.

  1. Quantitative motor-code analysis

We agree that the original t-SNE visualization was insufficient. We fit a K-means clustering model over the labeled motor-code representations, with the number of clusters set by the number of actions under evaluation. For each value of kk, we select the kk most frequent annotated actions and fit kk clusters over the frozen motor-code representations without using labels. We then label each cluster using the ground-truth label of the sample closest to its centroid and assign that label to the remaining samples in the cluster. Thus, labels are used only to name each learned cluster, using one labeled exemplar per cluster. The results are encouraging given that only one labeled exemplar per cluster is used.

kVerbNounAction21.0001.0001.00030.6451.0000.64540.7110.7110.52650.7210.6510.51260.6880.5420.43870.7170.4910.45380.6840.4390.42190.6500.4500.417100.5400.5710.429\begin{array}{cccc} \hline \text{k} & \text{Verb} & \text{Noun} & \text{Action} \\\\ \hline 2 & 1.000 & 1.000 & 1.000 \\\\ 3 & 0.645 & 1.000 & 0.645 \\\\ 4 & 0.711 & 0.711 & 0.526 \\\\ 5 & 0.721 & 0.651 & 0.512 \\\\ 6 & 0.688 & 0.542 & 0.438 \\\\ 7 & 0.717 & 0.491 & 0.453 \\\\ 8 & 0.684 & 0.439 & 0.421 \\\\ 9 & 0.650 & 0.450 & 0.417 \\\\ 10 & 0.540 & 0.571 & 0.429 \\\\ \hline \end{array}
  1. Consent, privacy, and human-subjects documentation

We apologize that the original submission did not adequately document the human-subjects procedures.

The collection was conducted under two IRB approvals because the initial approval expired during the overall project timeline. Participants received a fixed payment for their time and were reimbursed for food used during cooking. They recorded alone after being given the Aria glasses, EMG bands, and instructions. They were explicitly instructed that nobody else should be nearby, and manual review verified there were no bystanders in the released recordings. Participants were also instructed not to speak. In the small number of accidental instances containing speech, the affected portions were removed. Location and raw GPS metadata are not included in the release.

We also corrected the checklist inconsistency. The revised checklist consistently identifies the dataset, trained models, and training code as new assets. All of the details mentioned above (as well as additional details pertaining to the IRB) are now included in the Appendix and Checklist.

[1] Qian, Rui, et al. "Spatiotemporal contrastive video representation learning." Proceedings of the IEEE/CVF conference on computer vision and pattern recognition. 2021. [2] Bardes, Adrien, Jean Ponce, and Yann LeCun. "Vicregl: Self-supervised learning of local visual features." Advances in Neural Information Processing Systems 35 (2022): 8799-8810. [3] Wang, Xinlong, et al. "Dense contrastive learning for self-supervised visual pre-training." Proceedings of the IEEE/CVF conference on computer vision and pattern recognition. 2021.

Authors · CommentOpenReview ↗

We hope these additions address the main concerns raised in the review. We would appreciate your reconsideration of the paper in light of the new results and clarifications.

Reviewer FchDOpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper introduces MOTORSENSE, a dataset and learning framework for using surface electromyography (EMG) as an embodied signal for hand-centric action understanding. The dataset pairs egocentric video/audio from Project Aria glasses with bimanual wrist-worn EMG and IMU during unscripted kitchen manipulation. The authors learn discrete “motor codes” from EMG/IMU using a VQ-VAE and use these codes in two ways: as privileged pre-training targets for image/video backbones, and as conditioning inputs for an image-to-video diffusion model. The paper evaluates the resulting representations on action recognition, 3D hand-object reconstruction, and video diffusion.

Strengths and weaknesses

Strengths

  1. Motivation and problem framing. The paper studies a meaningful limitation of vision-only action learning: many aspects of hand-object manipulation, such as finger articulation, contact, and exerted effort, are only partially visible or fully occluded in egocentric video. EMG is a reasonable and interesting privileged signal for this setting.

  2. Valuable multimodal dataset direction. Pairing bimanual EMG/IMU with egocentric video in natural kitchen manipulation is useful for the community. Even though the participant count is small, the dataset is likely to be valuable for studying embodied action representations, sensor-to-vision distillation, and multimodal hand-object interaction.

  3. Simple and reusable representation idea. The motor-code formulation is easy to understand and potentially extensible: learn discrete codes from motor signals, then train visual backbones to predict these codes from pixels. This makes the contribution accessible and likely reproducible if the released data/code are complete.

  4. Promising downstream results. The action-recognition results are encouraging, especially under frozen evaluation, where motor-code pre-training improves over standard Hiera and EgoVideo initializations across several manipulation-centric benchmarks. The 3D reconstruction and diffusion experiments also suggest that the learned signal may transfer beyond classification.

  5. Relevant ablations and baselines are partially included. The paper includes an IMU-only ablation and compares against video-history conditioning for diffusion. These are useful first steps toward isolating the value of motor codes.

Weaknesses

  1. Dataset scale and subject diversity limit the strength of the claims. The dataset contains 25 hours but only 4 participants. For EMG, cross-subject variation is a central issue because signals depend on anatomy, electrode placement, skin contact, and band fit. The appendix also notes that participants with larger forearms were prioritized because the bands slip on slender wrists. This does not invalidate the dataset, but it weakens broad claims about general motor representations and population coverage.

  2. No held-out-subject evaluation. The validation split holds out recordings from unseen environments, but I did not find a leave-one-subject-out or held-out-participant evaluation. For an EMG-based representation, this is one of the most important missing validations. Without it, it is hard to know whether the learned motor codes capture participant-invariant motor structure or mostly participant/device-specific signatures.

  3. The main pre-training comparison is confounded by extra in-domain video exposure. Table 1 shows clear gains over off-the-shelf K400/Ego4D pre-training, but it does not fully isolate whether the improvement comes from EMG-derived motor-code supervision or from additional in-domain pre-training on MOTORSENSE clips. A matched visual-only pre-training baseline on the same clips would make the empirical claim much stronger.

  4. The EMG-vs-IMU ablation is helpful but not fully controlled. The appendix removes EMG and trains with raw IMU regression, whereas the full method uses discrete VQ motor-code histogram prediction over EMG+IMU. This changes both the modality and the learning objective. A cleaner isolation would include EMG-only motor codes, IMU-only VQ codes with the same histogram objective, raw EMG regression, and possibly random-code or shuffled-code controls.

  5. The semantic analysis of motor codes is mostly qualitative. The t-SNE visualization is suggestive, but it is based on a manually labeled visualization and does not establish that motor codes robustly recover action semantics. Quantitative analyses such as linear probing from motor-code histograms, clustering metrics, mutual information with verb/object labels, or stability across participants would better support the claim.

  6. Diffusion results are preliminary. The video diffusion section reports FVD, LPIPS, and PSNR on hand-centered crops, plus qualitative examples. However, these metrics do not directly measure physical/contact correctness or whether the generated motion follows the intended motor signal. The paper would benefit from failure cases, human preference evaluation, hand/contact consistency metrics, or a more explicit discussion that this part is exploratory.

  7. Limitations and ethics discussion are incomplete. The authors mention 8-channel EMG and 4 participants, which is good. However, the broader limitations should also discuss lack of cross-subject validation, possible selection bias from forearm fit, privacy risks from egocentric video/audio/GPS, and physiological/biometric sensitivity of EMG. The checklist also appears inconsistent in treating new assets, despite the paper claiming to release data and code.

Overall, I see the paper as promising and potentially useful, but not yet fully convincing. The idea is interesting and the dataset direction is valuable, but the current evidence does not fully support the breadth of the claims.

Questions
  1. Held-out-subject generalization: Could the authors report leave-one-subject-out or held-out-participant results for motor-code learning and downstream transfer? This would address whether the representation captures general motor structure rather than participant- or placement-specific EMG patterns. A convincing held-out-subject result would substantially increase my confidence.

  2. Matched visual-only pre-training control: Please compare motor-code pre-training against a visual-only objective trained on the same MOTORSENSE clips with similar compute, such as MAE, contrastive learning, future-frame prediction, or hand-pose/MPS-based supervision. This would help determine whether the gains come from EMG supervision rather than extra in-domain video pre-training. If this control performs similarly, my evaluation would decrease; if motor codes remain clearly better, my evaluation would increase.

  3. Cleaner modality/objective ablations: The current IMU-only ablation changes both the modality and the training objective. It would be useful to include EMG-only VQ codes, IMU-only VQ codes, raw EMG regression, and shuffled/random-code controls. These would clarify whether the benefit comes from EMG, from discretization, or from any temporally aligned sensor target.

  4. Quantitative motor-code analysis: The t-SNE plot is intuitive but not enough to establish semantic structure. A linear probe from frozen motor-code histograms to verb/object labels, clustering metrics, or cross-participant code stability analysis would make the motor-code claim more convincing.

  5. Privacy and human-subjects documentation: Please clarify consent, IRB/ethics review, participant compensation, whether raw audio/GPS are released or removed, and what anonymization is applied to egocentric video and physiological EMG. Stronger documentation here would reduce my ethical concerns.

My score would likely increase to borderline accept if the authors can show convincing held-out-subject generalization and a matched in-domain visual-only pre-training baseline where motor-code supervision remains clearly beneficial. My score would decrease if the gains mostly disappear under matched visual-only pre-training or if the dataset release lacks adequate consent/privacy safeguards.

Limitations

No. The authors acknowledge the 8-channel consumer-grade EMG device and the small number of participants, which is useful. However, the limitations should more directly address cross-subject generalization, band-fit/participant-selection bias, lack of matched visual-only pre-training controls, lack of statistical uncertainty, and privacy/consent risks from releasing egocentric video, audio/GPS metadata, and physiological EMG signals.

Final justification

After considering the rebuttal, I recommend increasing the score from Borderline Reject to Borderline Accept. The authors directly addressed the main concerns by adding matched visual-only pretraining baselines on the same MOTORSENSE clips, showing that the improvements are not explained by additional in-domain video exposure alone. They also provide promising held-out-participant results for motor-code prediction, although this evaluation does not extend to downstream action recognition or 3D reconstruction. The expanded modality and objective ablations further support the value of EMG-derived motor supervision, while the larger participant pool and clarified human-subject procedures address several secondary concerns. Remaining limitations include the restricted scope of cross-subject evaluation, lack of statistical uncertainty, and limited failure analysis for the diffusion component.

Formatting concerns

No formatting issues

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the constructive feedback. We are happy you find our work valuable for embodied action understanding, and find the downstream results encouraging. We structure our response to you based on the points you make in the Questions and Weaknesses sections. We are thankful you have considered increasing your score based on additional experimentation involving pre-training comparisons, held-out subject ablations, quantitative motor code analysis, and clearer human-subjects documentation. We have made all of these changes, described further below.

  1. Dataset scale and held-out-subject generalization

Since submission, we have collected data from six additional participants, each contributing approximately one hour. The revised dataset therefore contains approximately 31 hours of recordings from ten participants.

While transfer to external datasets is evidence of cross-subject generalization (for the tasks of action recognition and hand-object reconstruction), we agree cross-subject experiments for motor code prediction is particularly interesting. We now evaluate motor-code prediction from video on both seen and unseen participants.

Evaluation settingKL divergence↓Normalized ℓ1 distance↓Seen participants, cooking0.740.31Unseen participants, cooking0.830.33\begin{array}{lcc} \hline \text{Evaluation setting} & \text{KL divergence}\downarrow & \text{Normalized }\ell_1\text{ distance}\downarrow \\\\ \hline \text{Seen participants, cooking} & 0.74 & 0.31 \\\\ \text{Unseen participants, cooking} & 0.83 & 0.33 \\\\ \hline \end{array}

We additionally evaluate the model on unseen participants performing assembly, cleaning, and laundry.

Evaluation domainKL divergence↓Normalized ℓ1 distance↓Cooking0.830.33Assembly0.890.33Cleaning0.860.36Laundry0.910.40\begin{array}{lcc} \hline \text{Evaluation domain} & \text{KL divergence}\downarrow & \text{Normalized }\ell_1\text{ distance}\downarrow \\\\ \hline \text{Cooking} & 0.83 & 0.33 \\\\ \text{Assembly} & 0.89 & 0.33 \\\\ \text{Cleaning} & 0.86 & 0.36 \\\\ \text{Laundry} & 0.91 & 0.40 \\\\ \hline \end{array}

The decrease in performance from activity-domain shift is larger than the decrease from subject shift, particularly for laundry. This suggests that domain breadth is the larger remaining limitation and motivates the collection of a larger, multi-domain dataset. We leave this to future work.

  1. Matched visual-only pre-training controls + Modality and Objective Ablations

We agree the original comparisons did not isolate the benefit of motor-code supervision. For action recognition, we added a CVRL [1] baseline trained on the same MotorSense clips using the same Hiera initialization. For 3D hand-object reconstruction, we added DenseCL [3] and VICRegL [2] baselines pre-trained using only MotorSense RGB frames. We also expanded the modality and objective ablations to compare with pose baselines as well as several ablations (IMU, continuous vs discretized).

Motor-code supervision obtains the best MPJPE and Success@5% in the expanded comparison, whereas DenseCL and VICRegL trained on the same RGB frames perform worse than several existing baselines. Similar results hold for the CVRL baseline in action recognition. These results address your concerns the improvements arise merely from additional in-domain visual exposure.

Furthermore, the vision networks did not successfully predict raw EMG signals, and therefore performed poorly in downstream tasks. Discretization addresses this difficulty by making the learning of high-frequency EMG signals more tractable. The aggregation of these discrete codes into a histogram reduces the sensitivity of the model's predictions to precise temporal alignment with the EMG data, which can be difficult due to the frequency gap between the vision input and EMG targets. We also ran experiments using Aria MPS hand pose. We observed that pose supervision is weaker than motor code supervision. This is likely because MPS finger estimates can become noisy under occlusion, when hand-object interaction occurs. Wrist-mounted IMU remains available during visual occlusion and helps represent arm and wrist motion, as well as helps stabilize the network's interpretation of the EMG signals (EMG signals are noisy when the band undergoes jerky movements). All of this analysis is included in the Appendix.

Pre-training configurationEPIC verbEPIC nounMeccano actionK400 initialization only41.6515.1226.42Vision-only (CVRL)41.0119.3128.99Pose (no VQ-VAE)46.9220.1031.50Pose (VQ-VAE + histogram)43.2915.9026.05EMG-only (raw)42.2314.9926.62EMG-only (VQ-VAE)46.0116.3827.29EMG-only (VQ-VAE + histogram)48.5920.9933.36EMG + IMU (no VQ-VAE)45.8619.7231.76EMG + IMU (VQ-VAE)49.2020.2236.15EMG + IMU (ours)52.6422.2337.32\begin{array}{lccc} \hline \text{Pre-training configuration} & \text{EPIC verb} & \text{EPIC noun} & \text{Meccano action} \\\\ \hline \text{K400 initialization only} & 41.65 & 15.12 & 26.42 \\\\ \text{Vision-only (CVRL)} & 41.01 & 19.31 & 28.99 \\\\ \text{Pose (no VQ-VAE)} & 46.92 & 20.10 & 31.50 \\\\ \text{Pose (VQ-VAE + histogram)} & 43.29 & 15.90 & 26.05 \\\\ \text{EMG-only (raw)} & 42.23 & 14.99 & 26.62 \\\\ \text{EMG-only (VQ-VAE)} & 46.01 & 16.38 & 27.29 \\\\ \text{EMG-only (VQ-VAE + histogram)} & 48.59 & 20.99 & 33.36 \\\\ \text{EMG + IMU (no VQ-VAE)} & 45.86 & 19.72 & 31.76 \\\\ \text{EMG + IMU (VQ-VAE)} & 49.20 & 20.22 & 36.15 \\\\ \text{EMG + IMU (ours)} & \mathbf{52.64} & \mathbf{22.23} & \mathbf{37.32} \\\\ \hline \end{array}
\begin{array}{llcc} \hline \text{Method} & \text{Pre-training} & \text{MPJPE}\downarrow & \text{Success@5\\%}\uparrow \\\\ \hline \text{ARCTIC} & \text{IN} & 25.41 & 50.26 \\\\ \text{PixPro} & \text{IN} & 24.69 & 51.63 \\\\ \text{DenseCL} & \text{COCO + IN} & 27.33 & 48.82 \\\\ \text{SimHand} & \text{100DOH + Ego4D} & 34.94 & 41.90 \\\\ \text{PeCLR} & \text{100DOH + Ego4D} & 28.82 & 45.03 \\\\ \text{DenseCL} & \text{IN + MotorSense (RGB)} & 28.89 & 49.83 \\\\ \text{VICRegL} & \text{IN + MotorSense (RGB)} & 27.81 & 48.10 \\\\ \text{Ours} & \text{IN + MotorSense} & \mathbf{23.59} & \mathbf{55.03} \\\\ \hline \end{array}
  1. Quantitative motor-code analysis

We agree that the original t-SNE visualization was insufficient. We fit a K-means clustering model over the labeled motor-code representations, with the number of clusters set by the number of actions under evaluation. For each value of kk, we select the kk most frequent annotated actions and fit kk clusters over the frozen motor-code representations without using labels. We then label each cluster using the ground-truth label of the sample closest to its centroid and assign that label to the remaining samples in the cluster. Thus, labels are used only to name each learned cluster, using one labeled exemplar per cluster. The results are encouraging given that only one labeled exemplar per cluster is used.

kVerbNounAction21.0001.0001.00030.6451.0000.64540.7110.7110.52650.7210.6510.51260.6880.5420.43870.7170.4910.45380.6840.4390.42190.6500.4500.417100.5400.5710.429\begin{array}{cccc} \hline \text{k} & \text{Verb} & \text{Noun} & \text{Action} \\\\ \hline 2 & 1.000 & 1.000 & 1.000 \\\\ 3 & 0.645 & 1.000 & 0.645 \\\\ 4 & 0.711 & 0.711 & 0.526 \\\\ 5 & 0.721 & 0.651 & 0.512 \\\\ 6 & 0.688 & 0.542 & 0.438 \\\\ 7 & 0.717 & 0.491 & 0.453 \\\\ 8 & 0.684 & 0.439 & 0.421 \\\\ 9 & 0.650 & 0.450 & 0.417 \\\\ 10 & 0.540 & 0.571 & 0.429 \\\\ \hline \end{array}
  1. Consent, privacy, and human-subjects documentation

We apologize that the original submission did not provide sufficient information about human-subjects oversight and dataset governance. We obtained two IRB approvals before the corresponding stages of data collection because the earlier approval expired before the complete collection was finished. Participants received a fixed payment for their time and were reimbursed for food used during cooking. Participants recorded alone after receiving the Aria glasses, EMG bands, and recording instructions. Location metadata is not included in the release. They were explicitly instructed that no other person should be nearby, and our manual review verified there were no bystanders in the recordings. Participants were also instructed not to speak during recording. We manually and automatically reviewed the recordings for identifying content to make sure the data was anonymous. All of this and more is included in the Appendix.

We also apologize for the checklist inconsistency. We have corrected the asset-related checklist responses and now consistently describe the intended release of the dataset, trained models, and training code.

  1. Limitations and device fit

The fit issue arose from the mechanical mounting design of the particular MindRove bands used in our collection, rather than from an inherent limitation of surface EMG. Better EMG devices (e.g. Meta's Neural Bands) have customizable wrist mount sizes that would mitigate this issue. We also clarify the role of IMU. Rapid arm and wrist movements can negatively affect EMG measurements. Incorporating IMU into the motor representation provides information about these movements and helps stabilize interpretation of the EMG signal. We mention both of these points, as well as additional points in a new limitations section in the Appendix.

[1] Qian, Rui, et al. "Spatiotemporal contrastive video representation learning." Proceedings of the IEEE/CVF conference on computer vision and pattern recognition. 2021. [2] Bardes, Adrien, Jean Ponce, and Yann LeCun. "Vicregl: Self-supervised learning of local visual features." Advances in Neural Information Processing Systems 35 (2022): 8799-8810. [3] Wang, Xinlong, et al. "Dense contrastive learning for self-supervised visual pre-training." Proceedings of the IEEE/CVF conference on computer vision and pattern recognition. 2021.

Reviewer FchD · CommentOpenReview ↗

Thank you for the detailed rebuttal. The matched visual-only controls, expanded modality ablations, held-out-participant motor-code prediction results, and clarified human-subject procedures addressed our main concerns. I have therefore updated my review and increased my recommendation from Borderline Reject to Borderline Accept.

Ethics Reviewer AaBoOpenReview ↗
Scope
Moderate ethical concerns (can likely be resolved) (yellow)
Read ethics review
Ethics review

The authors do not handle human subjects aspects of the research correctly in the paper. This is particularly important when the authors plan to release a public data set.

  • There is selection bias in the subjects having to do with the fitting process. This needs to be acknowledged and its impact on the findings discussed.
  • The processes around human subjects are inadequately described. The Human Subjects checkbox says "Yes", but all the requirements are not met.
    • The NeurIPS code of ethics state that participants must be fairly compensated. There is no discussion of compensation.
    • Full text of instructions to participants are supposed to be included but are not.
  • The paper does not discuss any process of third-party human subjects review (IRB or equivalent). The fact that EMG devices are non-invasive is not the complete story. Data is recorded in naturalistic settings and the video data in particular may divulge personally-identifiable information. There is no discussion of recruitment or any kind of checking/anonymization of the video recordings. In my institution, this would require detailed IRB review.
  • The New Assets box is marked as "N/A" but clearly there are new assets in the form of code and data.

I'm optimistically marking this as Moderate. It is possible that best practices were followed but the authors just didn't write about it. If so, the ethical issues could be addressed by more thorough discussion of the human subjects aspect of the data collection in the paper: recruitment, compensation, data management esp. with respect to PII, and privacy risks should all be discussed. If, however, it turns out that the study was never reviewed or that privacy issues related to the data collection were not managed, then I would change my rating to Serious, and I believe the paper would have to be rejected.

1 comment
Authors · CommentOpenReview ↗

We thank the reviewer for the specific points of feedback. The reviewer is correct the procedures were followed, but they were not written up, and the checklist did not reflect the paper. We address each point in order. All material below now appears in the revised Appendix and Checklist.

1. Selection bias from the fitting process

Participants with larger forearms were prioritized because the bands slip on slender wrists and produce motion artifacts that render the data unusable. This biases the participant pool with respect to forearm circumference, which correlates with sex and with body size more generally. We emphasize this follows from the mechanical mounting of the MindRove bands rather than from surface EMG as a modality — newer bands with customizable sizing (e.g. Meta's Neural Bands) would not face this issue. We describe this in the paper, and that the EMG data collected in MotorSense is not representative of a general population.

2. Compensation

Participants received a fixed payment of $25 per recording session and were reimbursed for food used during cooking. This is now stated in the Appendix and in the corresponding checklist item.

3. Full text of instructions to participants

The complete instructions given to participants are now described in the revised Appendix. They cover installation and connection of the EMG streaming software, band placement on each wrist, the clench verification test used to confirm correct mounting, glasses configuration and recording start/stop, session length, and the post-recording offload procedure. The instructions state explicitly that participants should record alone, that no other person should be present, and that they should not speak during recording.

4. Third-party review, recruitment, PII, and privacy risk

We agree that non-invasiveness is not the only relevant question, and that our original checklist justification was inadequate. The collection was reviewed and approved by our institution's IRB.

Approval Every stage of collection was covered by an IRB approval; no recording took place outside an approved protocol.

Recruitment. Participants were recruited by convenience, through word of mouth within the authors' institutional network of students. Screening was limited to device-fit suitability and willingness to record cooking activity in a kitchen environment. Participation was voluntary. Participants were informed they could withdraw at any point during data collection, and recruitment materials described the recording, the intended public release, and the compensation before enrollment. All participants gave written informed consent before any recording. The consent covered participation, research use of the recorded video, audio, and EMG data, as well as public release of that data as a research dataset.

Risk disclosure. Participants were informed of the risks: minor skin irritation from the dry electrodes and band pressure, discomfort from extended wear, and the privacy risk in egocentric recording within their own home environment.

PII management. Participants recorded alone and were instructed that no one else be present; manual review confirmed no bystanders appear in the released recordings. Participants were instructed not to speak, and the small number of segments containing inadvertent speech were removed. Every recording was screened and de-identified before release according to a documented release protocol combining manual review with EgoBlur [1], targeting faces and other identifying content.

5. New assets

We have corrected the asset-related checklist responses and now consistently describe the intended release of the dataset, trained models, and training code.

[1] Raina, Nikhil, et al. "EgoBlur: Responsible innovation in Aria." arXiv preprint arXiv:2308.13093 (2023).

Ethics Reviewer 5vbrOpenReview ↗
Scope
Moderate ethical concerns (can likely be resolved) (yellow)
Read ethics review
Ethics review

The paper presents a method that uses Meta Aria glasses to capture finger movements, hand configurations, and interactions between the hand and surrounding objects for hand-object reconstruction, and pairs this with EMG data to develop an understanding of these actions. The main ethical concerns relate to the limited diversity of the participant sample and the reporting of participant consent for the visual data included in the paper. These issues can likely be addressed through clearer discussion of the study's limitations and improved transparency about participant consent.

  1. Limited participant diversity (Moderate) - The study includes only four participants, which is already acknowledged as a limitation. However, claims about the method's applicability to broader populations are not fully supported by such a small sample. Factors such as anatomical variation across different ethnicities, differences in hand shape and size, and the fit of EMG bands may affect the system's performance. How to address it: Clearly limit claims about generalisability, discuss how anatomical diversity may influence results, and include a more diverse participant population in future studies.

  2. Participant consent for images and videos (Moderate) - The paper includes images captured using Meta Aria glasses, but it does not explicitly state whether participants consented to the publication and research use of these images, videos, and associated sensor data. Although consent may have been obtained, the lack of documentation reduces transparency. How to address it: Explicitly describe the informed consent process, including whether participants agreed to the publication of images and videos, and state that the study received appropriate ethical approval where applicable.

1 comment
Authors · CommentOpenReview ↗

Participant Diversity and Consent

We thank the reviewer for the constructive assessment and for identifying two concrete issues. We address both below, and we have made corresponding revisions to the paper, the Appendix, and the checklist.

1. Limited participant diversity and the scope of our claims

We agree that the claims about the MotorSense dataset itself were broader than a four-participant sample supports. In the paper we observe that video models trained over MotorSense transfer to external datasets, which is indirect evidence of cross-subject generalization, but we agree it does not substitute for a direct evaluation. Regarding the dataset itself, two changes follow.

First, we have expanded the dataset. Since submission we collected data from six additional participants, giving approximately 31 hours from ten participants. We also now report a direct held-out-participant evaluation of motor-code prediction, alongside a cross-domain evaluation on unseen participants performing assembly, cleaning, and laundry. Please see Tables 1 and 2 in our response to Reviewer FchD.

Second, we have narrowed the claims and added an explicit discussion of anatomical selection bias. The MindRove bands we used slip on slender wrists and produce motion artifacts that render the data unusable, so participants with larger forearms were prioritized. This results in selection bias with respect to forearm circumference, which correlates with sex and with body size more generally. We note that this constraint follows from the mechanical mounting of the MindRove bands we used rather than from surface EMG as a modality — newer bands with customizable sizing (e.g. Meta's Neural Bands) would not face this issue. We therefore now state in the revised Limitations that MotorSense should not be read as population-representative.

Anatomical variation also affects the signal directly: EMG amplitude and the correspondence between individual electrodes and the underlying muscles vary with forearm circumference, and electrode placement. In the paper we discuss how this may affect the prediction of motor codes while still allowing for the learning of useful representations for action understanding.

2. Consent and publication of images and video

We apologize that the original submission did not document these procedures. They were followed but were not described in the paper. The revised Appendix now contains the following.

Ethical approval. The collection was reviewed and approved by our institution's IRB. It was conducted under two sequential approvals: the first protocol expired during the overall project timeline, and a second protocol was approved before the corresponding later sessions began. Every stage of collection was covered by an active approval.

Informed consent. All participants gave written informed consent before any recording. The consent covered (i) participation in the study, (ii) research use of the recorded video, audio, EMG, IMU, and derived data, (iii) public release of that data as a research dataset, and (iv) reproduction of individual frames and clips in publications and presentations, including this paper. Participants were told that they could withdraw at any point during collection.

Risk disclosure. Participants were informed of the risks of the procedure: minor skin irritation from the dry electrodes and band pressure, discomfort from extended wear, and the privacy risk of egocentric recording in their own home environment.

Recruitment, compensation, bystander handling, de-identification and screening, and release terms are documented in the revised Appendix and described more briefly in our response to Ethics Reviewer AaBo.

Comments on the paper

1 comment
Area Chair 3Kje · CommentOpenReview ↗

Please review author responses and respond!

All,

The authors have responded to many of your comments. Please review and follow up if any additional clarifications are needed.

-Your AC

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…