GLINT: Sparsely Gated Vision-Language Alignment for Fine-Grained Radiology Representations
Jonggwon Park, Seongeun Lee, Junhyun Park, Hannah Yun, Hyunwoong Kim, Sohyun Jeong, Hyewon Kang, Byungmu Yoon, Kyoyun Choi
NeurIPS 2026
TL;DR. GLINT learns the sparse correspondence between medical images and radiology reports from image-report pairs alone, enabling free-text localization and strong performance on both zero-shot and downstream tasks.
Abstract. Vision-language models (VLMs) for radiology have emerged as a scalable paradigm by leveraging image-report pairs naturally produced in clinical workflows. However, this pairing reveals a mismatch in scale: each finding occupies only a small region of the image, yet supervision is provided only at the global image-report level. This poses a central challenge: prior approaches spread weight densely across all patches rather than concentrating on the sparse subset relevant to a given query. To address this, we present GLINT (Gated Language-Image alignmeNT), a framework that models this sparse correspondence. On the alignment side, we introduce Sparsely Gated Alignment, a novel architecture in which a sigmoid gate over a separate gate embedding space activates only the patches relevant to each textual query, yielding sparsity. On the representation side, we add Dense Feature Regularization, which anchors the trainable encoder's intermediate features to a frozen self-supervised learning (SSL) teacher, preserving the fine-grained patch features that the gate relies on. The same recipe applies to both 2D chest X-ray (CXR) and 3D chest computed tomography (CT), built with DINOv3 and V-JEPA 2.1, respectively. GLINT enables zero-shot classification, grounding, and segmentation from free-text queries, and to our knowledge is the first to demonstrate zero-shot segmentation on 3D CT volumes without mask supervision. Notably, the most pronounced gains arise on zero-shot grounding and segmentation, where sparse, query-specific localization is required, consistent with our design intent. In downstream evaluation, GLINT outperforms both SSL encoders and medical VLMs on classification, report generation, and segmentation. Code is available at https://github.com/deepnoid-ai/GLINT.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:44 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
This paper introduces a sigmoid-gated alignment module and a teacher-anchored feature regularizer for fine-grained radiology vision-language learning, and reports broad gains on chest X-ray and chest CT. It received one accept, one borderline accept, and one reject.
I have read the authors' response, and it resolved the two validity questions and the clarity questions from my initial meta-review. On data splits, the authors audited every dataset for patient-level disjointness, found that one dataset had been split at the volume level, corrected it to a patient-level split, re-evaluated all methods, and the conclusions held. The chest CT dataset was already patient-level, with the official validation split used as the test set. On the initialization concern, they showed the gains survive when the larger teacher is removed. Even an ImageNet-pretrained variant that uses only a frozen copy of itself as the teacher, with no larger model involved, still exceeds the best prior results on every task group. So the advantage is not merely inherited from a strong backbone. They also defined the notation, separated the standard from the multi-positive contrastive branch, and reworded the sparsity claim to reflect that the sparsity is observed rather than imposed. The borderline-accept reviewer confirmed the response addressed their concerns.
I recommend acceptance. Two reviewers are positive, the results are broad and internally consistent, the leakage and fairness questions were answered on existing data, and the first zero-shot free-text segmentation on 3D CT is a real capability. The remaining reject did not respond during the discussion period, and its points about clarity, notation, and a possibly machine-drawn figure are the ones the response directly addressed, so I do not find them decisive against the two positive assessments.
The authors should redraw the architecture figure with a full legend, define all notation at first use, move the variance and significance numbers into the main tables, and add the missing early fine-grained-alignment baseline to the zero-shot table.
Final justification
Accept. The rebuttal resolved both validity questions (a patient-level split audit that corrected one dataset with unchanged conclusions, and an initialization isolation showing the gains survive without the larger teacher) and the notation and sparsity clarity items. Two reviewers are positive; the confident reject did not engage during discussion and its points were the ones the response addressed. The score-discrepancy flag on the accepting reviewer is resolved, since the review text justifies the score.
Read meta-review
Meta-review
This paper introduces a sigmoid-gated alignment module and a teacher-anchored feature regularizer for fine-grained radiology vision-language learning, and reports broad gains on chest X-ray and chest CT. It received one accept, one borderline accept, and one reject.
I have read the authors' response, and it resolved the two validity questions and the clarity questions from my initial meta-review. On data splits, the authors audited every dataset for patient-level disjointness, found that one dataset had been split at the volume level, corrected it to a patient-level split, re-evaluated all methods, and the conclusions held. The chest CT dataset was already patient-level, with the official validation split used as the test set. On the initialization concern, they showed the gains survive when the larger teacher is removed. Even an ImageNet-pretrained variant that uses only a frozen copy of itself as the teacher, with no larger model involved, still exceeds the best prior results on every task group. So the advantage is not merely inherited from a strong backbone. They also defined the notation, separated the standard from the multi-positive contrastive branch, and reworded the sparsity claim to reflect that the sparsity is observed rather than imposed. The borderline-accept reviewer confirmed the response addressed their concerns.
I recommend acceptance. Two reviewers are positive, the results are broad and internally consistent, the leakage and fairness questions were answered on existing data, and the first zero-shot free-text segmentation on 3D CT is a real capability. The remaining reject did not respond during the discussion period, and its points about clarity, notation, and a possibly machine-drawn figure are the ones the response directly addressed, so I do not find them decisive against the two positive assessments.
The authors should redraw the architecture figure with a full legend, define all notation at first use, move the variance and significance numbers into the main tables, and add the missing early fine-grained-alignment baseline to the zero-shot table.
Final justification
Accept. The rebuttal resolved both validity questions (a patient-level split audit that corrected one dataset with unchanged conclusions, and an initialization isolation showing the gains survive without the larger teacher) and the notation and sparsity clarity items. Two reviewers are positive; the confident reject did not engage during discussion and its points were the ones the response addressed. The score-discrepancy flag on the accepting reviewer is resolved, since the review text justifies the score.
1 comment
- Rating
- 2/6
- Confidence
- 5/5
- Quality
- 2/4
- Clarity
- 2/4
- Significance
- 2/4
- Originality
- 1/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper addresses the scale mismatch in radiology vision-language models (VLMs), where training is performed using global image–report pairs while clinically relevant findings often occupy only localized image regions. This paper propose GLINT (Gated Language–Image AlignmeNT), a framework that explicitly models sparse image–text correspondences through query-dependent region selection. GLINT consists of two components: Sparsely Gated Alignment (SGA), which employs a sigmoid-based gating mechanism to selectively activate image patches relevant to a textual query, and Dense Feature Regularization (DFR), which aligns intermediate features of the trainable encoder with those of a frozen self-supervised teacher to preserve fine-grained local representations. The proposed framework aims to improve lesion-level grounding and cross-modal alignment in radiology VLMs.
Strengths and weaknesses
Strengths : Comprehensive experiments on multiple datasets across three representative tasks demonstrate the effectiveness and generalizability of the proposed method.
Weaknesses: 1.The problem addressed in this paper is relatively old, and the proposed method appears to be a straightforward combination of existing techniques, with limited methodological novelty. 2.Figure 2 appears possibly AI-generated and is difficult to interpret. For example, it is unclear what the boxes, crosses, and sigma symbols represent. Several elements that should be explained in the caption are not annotated. In addition, the 2D illustrations appear inconsistent. I strongly suggest redrawing this figure for clarity. 3.In Table 1, it is unclear what the missing/default values indicate. The authors should explicitly explain their meaning. 4.The paper introduces the loss and gate temperatures, but it is unclear why they are initialized in log space. No sensitivity analysis is provided to justify this design choice. 5.The report generation task has already achieved strong performance with both recent MLLMs, such as Lingshu and Qwen3, and traditional radiology report generation methods, such as PromptMRG, which reports METEOR of 15.7% and ROUGE-L of 26.8%. Given these existing results, the motivation and practical significance of further pursuing this task should be better justified. 6.Many technical details are insufficiently explained. Several variables in the equations are not clearly defined, making the method difficult to follow. For example, the variables in Equations 1 and 2 are not fully explained; the meanings of (B) and (P) in Equation 3 are unclear; and the formulation of InfoNCE in Equation 4 is non-standard and difficult to verify. Overall, the writing raises concerns about possible AI-generated content. I recommend that the authors substantially rewrite the manuscript to improve clarity, rigor, and readability.
Questions
This paper seems to be AI-generated. The paper addresses a relatively well-studied problem, and the proposed approach appears to be a straightforward combination of existing techniques with limited novelty. The presentation is also difficult to follow: Figure 2 is unclear and poorly annotated, Table 1 contains unexplained default/missing values, and several design choices (e.g., log-space initialization of loss and gate temperatures) lack justification or sensitivity analysis. Furthermore, the motivation for further improving radiology report generation is insufficiently discussed given the already strong performance of recent MLLMs and existing report generation methods. Many technical details are inadequately explained, with undefined variables, ambiguous notation, and a non-standard formulation of InfoNCE loss that is difficult to verify. Overall, the manuscript requires substantial revision to improve its clarity, rigor, and technical presentation.
Limitations
The limitations section provides only the limiations onto the extension of data modality and the clinical practice validation, but does not offer a substantive discussion of the method's own problems. A thorough critique of the inherent limitations of such methods when applied to this problem domain, as well as the specific deficiencies of the proposed approach, is notably absent.
Formatting concerns
nil
1 comment
Rebuttal
We thank the reviewer for the detailed reading. The presentation issues raised can be addressed directly, and we also clarify how our method differs from prior work in response to the concern about methodological novelty. We respond to each point below.
W1. problem definition & limited methodological novelty.
The problem is indeed not new — fine-grained alignment from image-level reports has been pursued since GLoRIA [22] and MGCA [57]. However, it remains far from solved. Our zero-shot segmentation Dice rises from 0.332 to 0.434 on ChestX-Det and 0.171 to 0.317 on SIIM over the prior best, indicating that substantial room for progress remains.
Our method builds on gating concept from [45], but that work gates self-attention inside a language model. SGA is a different architecture — patch and text features are projected into a separate gate embedding space, where a per-patch sigmoid gate conditions image aggregation on the text query. To reinforce the design priciples beyond this novel architecture, we further incorporate the simple yet effective DFR objective design, promoting sparse vision-language alignment and fine-grained patch representations.
This architectural difference also enables a capability beyond a straightforward combination of existing techniques. GLINT-CT is, to our knowledge, the first to perform zero-shot free-text segmentation on 3D CT without mask supervision, reaching 0.128 Dice on ReXGroundingCT and matching supervised SAT [74] (0.131). Prior 3D VLMs [20, 52, 10, 41] do not support zero-shot free-text segmentation, and VoxTell [48] requires large-scale masks.
W2. Figure 2 clarity.
We agree that the figure is hard to interpret in its current form, and we will redraw it with clearer annotation. To be clear about how it was produced, the figure is a vector diagram drawn by the authors, and the images in it are evaluation-set cases with actual model outputs.
The symbols are defined in the method section: is the sigmoid on the temperature-scaled cosine similarity (Sec. 3.2), and is the element-wise multiplication of gate scores with L2-normalized patch embeddings (Eq. (1)). The figure should not require reconstructing these from the text, so we will add a legend describing each symbol.
The inconsistency arises because Figure 2 illustrates the overall pipeline rather than a single example. The thumbnails indicate where each modality enters the framework, so the inputs in panel (a) and the maps in panel (b) come from different cases. We will use the same CXR and CT images throughout the figure.
W3. Table 1 missing values.
The "—" entries indicate cells for which no value is reported, for two distinct reasons. Except for MedSigLIP [50], the baseline numbers are taken from RadZero [42], whose protocol and splits we follow for comparability (Appendix D.1); within that protocol GLoRIA [22] and KAD [72] are evaluated only on classification and ChestX-Det10 grounding, not on MS-CXR or segmentation, so these results are left blank. MedSigLIP is a different case: we evaluated it ourselves, but it produces only global image-text embeddings with no patch-text scoring, so localization is structurally undefined for it rather than merely unevaluated. We will state both cases in the caption, distinguish them with separate symbols, and identify which values are taken from prior work.
W4. temperature sensitivity analysis.
We should have distinguished two separate points. The values and are initializations, whereas log-space refers to the parameterization, where we optimize rather than . Both choices follow established practice: is the initialization used by CLIP [46], whose softmax-normalized form matches our alignment loss, and follows SigLIP (Zhai et al.), whose sigmoid formulation matches our gate. Log-space parameterization is used in both, as it keeps positive without an explicit constraint and makes gradient updates multiplicative in , which enters the loss as a divisor. We will state these references in the revision.
The absence of a sensitivity analysis is a fair point. We trained GLINT-CXR over the full grid of at 0.04, 0.07, 0.10 crossed with at 0.05, 0.10, 0.15, and evaluated all nine models zero-shot. Task-wise averages, computed as in Table 6:
| Classification | Grounding | Segmentation | ||
|---|---|---|---|---|
| 0.04 | 0.05 | 0.871 | 0.782 | 0.353 |
| 0.04 | 0.10 | 0.876 | 0.796 | 0.365 |
| 0.04 | 0.15 | 0.873 | 0.770 | 0.315 |
| 0.07 | 0.05 | 0.868 | 0.767 | 0.353 |
| 0.07 | 0.10 | 0.877 | 0.810 | 0.375 |
| 0.07 | 0.15 | 0.873 | 0.782 | 0.323 |
| 0.10 | 0.05 | 0.872 | 0.797 | 0.358 |
| 0.10 | 0.10 | 0.874 | 0.786 | 0.361 |
| 0.10 | 0.15 | 0.868 | 0.763 | 0.305 |
Classification is insensitive (spread 0.009), while localization is not (0.047 for grounding, 0.070 for segmentation), and the sensitivity is primarily driven by . At 0.15 the gate is too soft to be selective and segmentation falls to 0.305–0.323 for every , while at 0.05 the gate becomes nearly binary and also underperforms. Since sets gate sharpness, this behavior is consistent with the intended design. The initialization values were adopted from prior work rather than tuned for our work, and the sweep provides empirical support for these choices.
Reference: Zhai et al. Sigmoid Loss for Language Image Pre-Training. ICCV 2023.
W5. report generation task.
Report generation is not our primary target task, and we should have made this clearer. Rather, it serves as one of three probes for evaluating the transferability of the learned representation, alongside classification and segmentation. In Table 2, the encoder is frozen and an R2Gen [12] decoder is attached identically for GLINT and all baselines, ensuring that performance differences reflect the quality of the encoder representation rather than decoder design or hyperparameter tuning. We adopt a protocol similar to that of BenchX [76], a chest X-ray benchmark that evaluates medical VLP encoders on the same three downstream tasks, including the same R2Gen decoder for report generation. We will present this evaluation explicitly as a representation probe in Sec. 4.2 and clarify that our claims are limited to encoder comparison.
W6 & AC meta-review Q3. notations.
We thank the reviewer for pointing out that the notation is hard to follow. We agree that introducing these symbols in running text, rather than alongside the equations where they first appear, makes them difficult to track. Specifically, the symbols in Eqs. (1)-(2) are defined in Sec. 3.2, and is defined in Sec. 3.3. In the revision, each symbol will be defined adjacent to its first use.
| Symbol | Meaning |
|---|---|
| number of patch tokens on the 2D or 3D patch grid | |
| embedding of patch | |
| sentence embedding | |
| the two gate-head MLP branches | |
| gate score for patch | |
| learnable gate and loss temperatures | |
| learnable weight on the gate confidence shift | |
| mini-batch size | |
| student and teacher patch tokens at layers | |
| MLP projector matching student to teacher dimension | |
| weight on the DFR loss | |
| number of sentences and images in a mini-batch | |
| index of the image that sentence came from |
Distinguishing the two branches of Eq. (4). The two branches are currently written on a single line. We will present them as separately labeled equations for readability.
The text-to-image branch, , follows the standard InfoNCE formulation: the positive is the source image of the sentence, and the denominator runs over all images in the mini-batch.
The image-to-text branch, , adopts the multi-positive variant (MP-NCE) [29, 42], as described in Sec. 3.4. Because each report is decomposed into multiple positive sentences, sibling sentences are additional positives rather than negatives. Its denominator accordingly includes the positive pair with only those sentences satisfying , i.e., sentences originating from different images. A standard single-positive InfoNCE objective would instead treat sibling sentences as negatives, thereby pushing apart pairs that should be pulled together.
Limitations.
We agree that the current section primarily discusses the scope of our study rather than the proposed method itself, and we will revise it to include the following method-level limitations.
Dependence on a self-supervised pretrained encoder. GLINT uses such an encoder in two places: as the initialization of the trainable encoder, and as the frozen teacher that DFR anchors to. Its performance depends substantially on both, and applying it to a different modality may require identifying or pretraining a suitable encoder.
No explicit handling of in-batch false negatives. Our contrastive objective treats all sentences from other images in the batch as negatives, although in radiology many sentences from different studies may be semantically equivalent. As a result, semantically matched image–sentence pairs can be incorrectly treated as negatives during training. Objectives that account for such false negatives, for example by identifying these pairs or by adopting soft-label formulations, are promising ways to address this, and we leave them for future work.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes GLINT, a sparsely gated alignment framework for radiology vision-language pretraining. The paper focuses on the problem of fine-grained alignment in radiology VLMs, which has been widely studied in the community. The proposed method shows a relatively high degree of novelty, the experimental coverage is broad, and the results are generally convincing.
Strengths and weaknesses
Strengths
- The paper studies fine-grained alignment in medical imaging, an important problem that has received sustained attention in the community.
- The proposed method is novel. The idea of using a gating mechanism instead of softmax attention is clear and intuitive, and it directly addresses the limitations of softmax-based attention.
- The experiments are relatively comprehensive. The method is evaluated on both X-ray and CT modalities, and it demonstrates strong performance on both.
Weaknesses
- The authors use the term “explicit sparsity” to describe the proposed method. However, GLINT does not introduce an explicit sparsity loss or a structural constraint to enforce sparsity, so I find this claim questionable.
- In Table 2, the paper uses MGCA as a baseline for comparison, but MGCA does not appear in Table 1. Since MGCA is an early and representative method for fine-grained alignment, it should be included in both sets of experiments.
- The visual encoder of GLINT is initialized from pretrained vision foundation models, and during training it is further supervised by a larger teacher model from the same model family through teacher-student regularization. In contrast, some baselines may be initialized from ImageNet or even trained from random initialization. This makes the comparison potentially unfair.
Questions
Refer to weaknesses.
Limitations
Yes
Formatting concerns
Nil.
1 comment
Rebuttal
We thank the reviewer for the constructive review and for finding the proposed method novel. We address the three weaknesses below.
W1. The authors use the term "explicit sparsity" to describe the proposed method. However, GLINT does not introduce an explicit sparsity loss or a structural constraint to enforce sparsity, so I find this claim questionable.
AC meta-review Q3: ... justify the term "explicit sparsity."
We accept this point and will rephrase the wording. Sparsity in GLINT is deliberate by design, even though it is not imposed by a penalty. Softmax normalization requires the aggregation weights to sum to one, so every patch retains non-zero mass and attention of some patches must always be activated. We chose a per-patch sigmoid with separate embedding space to remove this constraint: it carries no normalization, so irrelevant patches can be suppressed entirely and every gate can approach zero when no region corresponds to the query at all. DFR then suppresses the spurious activations that such unconstrained weighting can produce, by anchoring patch features to the frozen self-supervised teacher. Sec. 5.2.1 shows that the learned gates are sparse.
That verification is what Fig. 3 reports. Patch-wise sparsity on ReXGroundingCT rises from 0.000 for the softmax-based VL-CABS baselines, where every patch remains active, to 0.872 once softmax is replaced by the gate, and to 0.975 in full GLINT, approaching the 0.996 background ratio of the data.
We will therefore revise the wording to reflect this distinction: rather than describing the method as enforcing sparsity, we will state that the gate permits sparse activation and report the sparsity we observe as an empirical result.
W2. In Table 2, the paper uses MGCA as a baseline for comparison, but MGCA does not appear in Table 1. Since MGCA is an early and representative method for fine-grained alignment, it should be included in both sets of experiments.
MGCA is absent from Table 1 because it does not define a zero-shot inference protocol. Its original paper evaluates transfer settings (linear classification, detection, and segmentation with frozen features), reporting no zero-shot evaluation and no prompt design. Its CTA module yields token-level correspondences, but the paper reports only qualitative attention maps with no quantitative localization protocol, so there is no defined procedure for producing a grounding score or a segmentation mask from it; any such procedure would be ours rather than MGCA's. We therefore compared MGCA in downstream tasks as it was designed for.
W3. The visual encoder of GLINT is initialized from pretrained vision foundation models, and during training it is further supervised by a larger teacher model from the same model family through teacher-student regularization. In contrast, some baselines may be initialized from ImageNet or even trained from random initialization. This makes the comparison potentially unfair.
AC meta-review Q2: Isolate the method from its initialization. Your encoder starts from a strong vision foundation model and is further regularized by a larger same-family teacher that the baselines do not receive.
We appreciate this concern, which the AC also raises. The most direct answer is to take each advantage away and see whether the result survives, so we retrained the model under each removal. Task-wise averages, as in Table 6:
| initialization | DFR | CXR classification | CXR grounding | CXR segmentation | CT classification | CT segmentation |
|---|---|---|---|---|---|---|
| best prior work (zero-shot) | 0.848 | 0.733 | 0.252 | 0.760 | - | |
| pretrained initialization | ✓ | 0.877 | 0.810 | 0.375 | 0.819 | 0.128 |
| pretrained initialization | – | 0.870 | 0.772 | 0.369 | 0.812 | 0.119 |
| from scratch | ✓ | 0.822 | 0.677 | 0.195 | 0.781 | 0.114 |
| from scratch | – | 0.776 | 0.535 | 0.111 | 0.736 | 0.005 |
With the larger teacher removed, the margin holds. Even without teacher distillation, the model still exceeds the best prior result on every benchmark for which a zero-shot baseline exists. The teacher does refine the outcome, most visibly on grounding, but exceeding prior work does not depend on it.
Removing pretrained initialization does substantially degrade performance, and we acknowledge this without qualification. However, this is not unique to GLINT: many prior VLMs likewise rely on pretrained vision encoders or masked image modeling. We will therefore state pretrained initialization explicitly as a prerequisite of our framework rather than leaving it implicit. Notably, DFR is not simply a channel for the teacher—applied from scratch, it still lifts grounding from 0.535 to 0.677 and CT classification from 0.736 to 0.781, indicating that initialization and distillation contribute through complementary mechanisms.
Replacing our initialization with the baselines' own. The baselines are themselves built on pretrained encoders, so the sharper test is to retrain our framework on their checkpoints:
| initialization | resolution | DFR teacher | CXR classification | CXR grounding | CXR segmentation | |
|---|---|---|---|---|---|---|
| best prior work | — | — | — | 0.848 | 0.733 | 0.252 |
| CARZero [28] | ViT-B/16, M3AE (Chen et al.) | 224 | — | 0.836 | 0.646 | 0.193 |
| ours | ViT-B/16, M3AE (Chen et al.) | 224 | self | 0.856 | 0.671 | 0.229 |
| RadZero [42] | ViT-B/14, XrayDINOv2 (Chambon et al.) | 518 | — | 0.842 | 0.733 | 0.252 |
| ours | ViT-B/14, DINOv2 [39] | 518 | larger | 0.852 | 0.762 | 0.327 |
| ours | ViT-B/14, SSL on ImageNet-21k (Venkataramanan et al.) | 518 | self | 0.857 | 0.760 | 0.300 |
Bold marks values above the best prior result; "self" means the teacher is a frozen copy of the student, so no larger model is involved.
Using CARZero's M3AE backbone and resolution and without a larger teacher, we improve on it across all three task groups, though localization at 224 stays below the best prior figures, which come from higher-resolution models. Against RadZero the initialization runs against us — its DINOv2 is radiology-adapted while ours is the generic checkpoint — and we still exceed RadZero on all three tasks. Further, an ImageNet-21k pretrained ViT-B, using DFR with a frozen copy of itself as the teacher, surpasses the best prior on all three task groups, without medical pretraining, a larger teacher, and VFM pretrained with large-scale dataset.
In summary, removing the larger teacher does not change the ranking, while replacing our initialization with those used by the baselines preserves the same conclusion. Pretraining itself remains a prerequisite, but this should be viewed as an assumption of the framework rather than an unfair advantage.
References:
- Chen et al. Multi-Modal Masked Autoencoders for Medical Vision-and-Language Pre-Training. MICCAI 2022.
- Chambon et al. CheXpert Plus: Augmenting a Large Chest X-ray Dataset with Text Radiology Reports. arXiv:2405.19538, 2024.
- Venkataramanan et al. Franca: Nested Matryoshka Clustering for Scalable Visual Representation Learning. arXiv:2507.14137, 2025.
- Rating
- 5/6
- Confidence
- 5/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This study addresses the scale mismatch problem in Radiology VLMs, where each finding occupies only a small region of the image, yet supervision is provided exclusively at the global image-report level. While existing approaches assign uniform weights to all patches, this work introduces the GLINT (Gated Language-Image alignmeNT) method to account for sparse correspondence, thereby proposing a novel Sparsely Gated Alignment framework.
Strengths and weaknesses
Strengths
- GLINT supports zero-shot classification, grounding, and segmentation from free-text queries. It is the first to demonstrate zero-shot segmentation on 3D CT volumes without mask supervision.
- This consistently outperforms SSL encoders and medical VLMs on classification, report generation, and supervised segmentation across CXR and CT. Weaknesses -Since the CT-RATE dataset consists of 50,188 volumes reconstructed from 25,692 CT scans across approximately 20,000 unique patients, it contains a significant number of duplicate or overlapping images. Consequently, creating a test set through random sampling leads to severe data leakage.
Questions
Since the CT-RATE dataset consists of approximately 50,188 volumes reconstructed from 25,692 CT scans across roughly 20,000 unique patients, it contains a substantial number of overlapping images. Creating a test set through random sampling inevitably introduces data leakage. The authors must re-partition the dataset using a strict patient-level split.
The reported results lack essential statistical metrics, including standard deviations (SD), confidence intervals (CI), and statistical significance tests (i.e., Dice metric). These must be provided to ensure the reliability of the findings. To evaluate run-to-run variability, how many time do you test?
Limitations
N/A
Formatting concerns
N/A
1 comment
Rebuttal
We thank you for the positive assessment and the careful questions on data splits and statistics.
Q1. Since CT-RATE consists of 50,188 volumes reconstructed from 25,692 CT scans across roughly 20,000 unique patients, it contains a significant number of duplicate or overlapping images. Creating a test split through random sampling likely introduces data leakage.
We agree this is a critical concern, and apologize that our description in Section 4.1 was insufficient. The issue does not arise here, because our sampling was performed at the patient level, and our test set is the official CT-RATE validation split rather than a randomly drawn subset.
| Stage | Train | Validation | Test | Total |
|---|---|---|---|---|
| CT-RATE v2.0, all volumes | 50,188 | |||
| − 792 excluded (non-chest, unusable volumes) | 49,396 | |||
| Volumes after patient-disjoint split | 43,400 | 2,994 | 3,002 | 49,396 |
| Unique patients | 18,696 | 1,304 | 1,304 | 21,304 |
| − exclusions (train/validation only) | 43,337 | 2,990 | 3,002 | 49,329 |
CT-RATE's official training split covers 20,000 patients, which we divide into 18,696 for training and 1,304 for validation, and its official validation split of 1,304 further patients serves as our test set. All splits are performed at the patient level, so the duplicate reconstructions the reviewer notes cannot span across two splits. All splits are performed at the patient level, so the duplicate reconstructions the reviewer notes cannot span across two splits.
The reduction to the 43,337 / 2,990 counts in Section 4.1 reflects two exclusions applied after the split, both training-side only: volumes whose report decomposition (Sec. 3.1) yields no sentences, and volumes overlapping ReXGroundingCT, as a cross-task precaution for zero-shot segmentation. The test split is never altered — all 3,002 official validation volumes are used in full for every task. We will state this protocol explicitly in the revision.
Q2. The reported results lack essential statistical metrics, including standard deviations, confidence intervals, and statistical tests. To evaluate run-to-run variability, how many trials do you use?
We use three independent trials with different random seeds, reporting the mean and standard deviation across them. This is already provided in Appendix F (Tables 12–15), but the comparison tables themselves carried no variability information, which is where margins matter most.
Zero-shot (Tables 1, 3). Baseline numbers are cited from prior work as single values, so seed-level variability is available only for our model; ours below is the mean ± standard deviation over three seeds. What can be checked is whether our margins survive seed variation:
| CXR zero-shot | PadChest | PadChest20 | ChestXray14 | ChestX-Det10 | CheXpert | Open-I | ChestX-Det10-g | MS-CXR | ChestX-Det-seg | SIIM-seg |
|---|---|---|---|---|---|---|---|---|---|---|
| CARZero [28] | 0.810 | 0.837 | 0.811 | 0.796 | 0.923 | 0.838 | 0.543 | 0.749 | 0.304 | 0.081 |
| RadZero [42] | 0.841 | 0.871 | 0.804 | 0.787 | 0.900 | 0.847 | 0.622 | 0.844 | 0.332 | 0.171 |
| GLINT-CXR | 0.860±0.003 | 0.908±0.009 | 0.827±0.003 | 0.845±0.007 | 0.915±0.006 | 0.879±0.002 | 0.711±0.022 | 0.904±0.032 | 0.429±0.004 | 0.305±0.025 |
| CT zero-shot | CT-RATE | RAD-ChestCT |
|---|---|---|
| ViSD-Boost [10] | 0.790 | 0.694 |
| COLIPRI [56] | 0.785 | 0.730 |
| GLINT-CT | 0.849±0.001 | 0.780±0.010 |
Every margin over the strongest baseline exceeds our seed spread, with one exception.
Downstream (Tables 2, 5). These baselines are our own evaluations under a frozen-encoder protocol, so we trained two additional seeds for each setting and report mean ± std over three seeds. Every entry below is a mean ± standard deviation, and bold marks the highest mean in each column:
| CXR downstream | ChestXray14 | VinDr-CXR | RSNA-PN | SIIM | METEOR | ROUGE-L | CheXbert | RadGraph | ChestX-Det-seg | SIIM-seg |
|---|---|---|---|---|---|---|---|---|---|---|
| DINOv3 [53] | 0.806±0.001 | 0.883±0.015 | 0.879±0.003 | 0.931±0.006 | 0.130±0.003 | 0.238±0.002 | 0.238±0.004 | 0.202±0.004 | 0.765±0.065 | 0.479±0.077 |
| MGCA [57] | 0.808±0.001 | 0.923±0.000 | 0.892±0.001 | 0.928±0.003 | 0.131±0.001 | 0.237±0.001 | 0.259±0.008 | 0.204±0.002 | 0.779±0.041 | 0.514±0.110 |
| KAD [72] | 0.812±0.003 | 0.934±0.001 | 0.896±0.002 | 0.937±0.002 | 0.135±0.002 | 0.243±0.001 | 0.277±0.005 | 0.215±0.003 | 0.789±0.007 | 0.539±0.021 |
| MedKLIP [62] | 0.801±0.000 | 0.919±0.005 | 0.893±0.001 | 0.937±0.002 | 0.135±0.001 | 0.237±0.001 | 0.268±0.007 | 0.204±0.002 | 0.781±0.020 | 0.507±0.009 |
| MRM [75] | 0.818±0.000 | 0.907±0.006 | 0.893±0.001 | 0.937±0.000 | 0.133±0.003 | 0.240±0.004 | 0.271±0.003 | 0.209±0.002 | 0.793±0.014 | 0.577±0.048 |
| MAVL [44] | 0.802±0.001 | 0.914±0.004 | 0.892±0.002 | 0.944±0.001 | 0.133±0.001 | 0.240±0.002 | 0.278±0.005 | 0.211±0.003 | 0.765±0.003 | 0.551±0.037 |
| CheXWorld [68] | 0.814±0.002 | 0.922±0.004 | 0.888±0.003 | 0.937±0.002 | 0.133±0.000 | 0.238±0.001 | 0.259±0.006 | 0.208±0.001 | 0.795±0.006 | 0.586±0.007 |
| RAD-DINO [43] | 0.831±0.001 | 0.936±0.003 | 0.891±0.001 | 0.953±0.002 | 0.137±0.001 | 0.242±0.001 | 0.283±0.007 | 0.213±0.000 | 0.808±0.003 | 0.631±0.054 |
| GLINT-CXR | 0.847±0.001 | 0.944±0.001 | 0.902±0.001 | 0.975±0.001 | 0.143±0.001 | 0.249±0.002 | 0.314±0.002 | 0.225±0.002 | 0.818±0.007 | 0.730±0.049 |
| CT downstream | CT-RATE | RSNA-PE | LIDC* | METEOR | ROUGE-L | RadBERT | CRG | MSD-Lung | NSCLC |
|---|---|---|---|---|---|---|---|---|---|
| V-JEPA 2.1 [37] | 0.857±0.003 | 0.627±0.015 | 0.788±0.017 | 0.223±0.008 | 0.271±0.018 | 0.338±0.007 | 0.397±0.004 | 0.532±0.037 | 0.561±0.003 |
| CT-CLIP [20] | 0.766±0.002 | 0.595±0.019 | 0.786±0.008 | 0.191±0.005 | 0.274±0.005 | 0.124±0.003 | 0.352±0.002 | 0.022±0.035 | 0.360±0.017 |
| fVLM [52] | 0.807±0.000 | 0.649±0.009 | 0.730±0.029 | 0.224±0.001 | 0.290±0.001 | 0.327±0.007 | 0.394±0.003 | – | – |
| ViSD-Boost [10] | 0.744±0.003 | 0.597±0.019 | 0.603±0.041 | 0.213±0.004 | 0.278±0.006 | 0.226±0.032 | 0.358±0.005 | – | – |
| COLIPRI [56] | 0.876±0.000 | 0.673±0.009 | 0.874±0.024 | 0.228±0.009 | 0.289±0.004 | 0.391±0.018 | 0.425±0.008 | 0.568±0.052 | 0.581±0.012 |
| GLINT-CT | 0.876±0.002 | 0.677±0.021 | 0.901±0.015 | 0.221±0.005 | 0.226±0.017 | 0.399±0.001 | 0.432±0.003 | 0.613±0.031 | 0.587±0.010 |
*corrected patient-disjoint split (see the below).
On CXR, GLINT-CXR leads on all ten metrics by margins exceeding the combined spreads. On CT, GLINT-CT leads clearly on LIDC-IDRI, both segmentation benchmarks, and both clinical-content report metrics, and is statistically indistinguishable from COLIPRI on CT-RATE and RSNA-PE; the NLG metrics remain the exception, as already noted in Sec. 5.1.
AC meta-review Q1: State, for every dataset, whether the train, validation, and test splits are patient-level disjoint.
Additional: complete per-dataset split audit
We extend the review to every dataset, which also addresses the AC's request. Split sources and per-split counts are in Appendix D and Table 9; the review below adds the patient-level verification we had not stated explicitly. We focus on datasets used for VL alignment and downstream tasks, since these are the settings where a split boundary can be violated; zero-shot evaluation involves no training, so the only requirement there is no overlap with our VL alignment data.
| Dataset | Task | Test split | Patient-level verification |
|---|---|---|---|
| MIMIC-CXR | VL alignment / CXR report generation | official | patient disjoint |
| ChestXray14 | CXR classification | official | — |
| VinDr-CXR | CXR classification | official | — |
| RSNA-PN | CXR classification | ours | patient disjoint |
| SIIM | CXR classification, segmentation | BenchX [76] | patient disjoint |
| ChestX-Det | CXR segmentation | official | — |
| CT-RATE | VL alignment / CT classification, report generation | official | patient disjoint |
| RSNA-PE | CT classification | Ke et al. [26] | study-level disjoint |
| LIDC-IDRI | CT classification | ours | volume-level → corrected to patient-level |
| MSD-Lung | CT segmentation | ours | patient disjoint |
| NSCLC-Radiomics | CT segmentation | ours | patient disjoint |
Zero-shot evaluation. All zero-shot benchmarks are external to MIMIC-CXR and CT-RATE, except MS-CXR and ReXGroundingCT, whose test data we remove from the corresponding alignment training set.
Issue found and corrected — LIDC-IDRI. Our LIDC-IDRI split was constructed at the volume level. LIDC contains 1,010 scans from 1,002 patients, and a small number of patients had scans in more than one split. We rebuilt it by moving every affected patient into the test set, which preserves all original test patients and makes the three splits patient-disjoint; counts change from 709 / 151 / 150 to 705 / 148 / 157. All methods were then re-evaluated on the corrected split under a single shared seed:
| Method | Paper (Table 5) | Patient-disjoint split |
|---|---|---|
| V-JEPA 2.1 [37] | 0.798 | 0.771 |
| CT-CLIP [20] | 0.755 | 0.777 |
| fVLM [52] | 0.726 | 0.733 |
| ViSD-Boost [10] | 0.518 | 0.625 |
| COLIPRI [56] | 0.906 | 0.874 |
| GLINT-CT | 0.916 | 0.886 |
The trend is unchanged: GLINT-CT remains strongest, with a comparable margin over the next-best baseline (0.010–0.012). We will replace the LIDC-IDRI column in Table 5 and describe the corrected split in Appendix D.4.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
We thank the AC for prioritizing these three points. All three points have been addressed in detail in the corresponding reviewer threads. We briefly summarize them here.
Q1. We re-checked patient-level disjointness across all datasets. CT-RATE, which the reviewer raised, is unaffected: our splits are patient-level, and our test set is the official validation split. In LIDC-IDRI the split had been constructed at the volume level. This affected only 7 of the 1,010 volumes. We moved them into the test set (709 / 151 / 150 → 705 / 148 / 157), re-evaluated all methods on the corrected split, and the conclusions are unchanged. All dataset splits have now been re-verified.
Q2. We report three settings. (i) Even without the larger teacher, our model outperforms the best prior work. (ii) Under matched initialization, it improves over both CARZero and RadZero — backbone and resolution matched exactly for CARZero, and for RadZero the comparison is conservative since RadZero benefits from a radiology-adapted XrayDINOv2 initialization, whereas ours uses the generic DINOv2 checkpoint. (iii) Even an ImageNet-21k SSL initialization with a frozen copy of itself as the teacher, with no medical pretraining and no larger teacher, surpasses the best prior result.
Q3. We have clarified where the notation and the loss formulation could cause confusion, and will state both in the paper. On "explicit sparsity": the sparsity is by design but is not enforced by a penalty, so we will revise the wording. Figure 3 shows that the sparsity emerges empirically from the design.
We thank the AC and all reviewers for their careful consideration. We hope the detailed responses provided in each thread will be taken into account during the final assessment.