UTOPI: Efficient Egocentric Long-Video Understanding in AR via User-Guided Token Pre-Compression
Ziqi Wang, Su Chen, Qiance Tang, Jieyu Lin, Ziyun Li, Barbara De Salvo, Sai Qian Zhang
NeurIPS 2026
TL;DR. UTOPI uses head-motion and eye-gaze signals from AR glasses to prune redundant visual tokens before the language model, cutting up to 95% of tokens on egocentric long videos without losing accuracy.
Abstract. As long-video understanding continues to gain traction, Augmented Reality (AR) devices emerge as a compelling deployment platform. However, egocentric videos exhibit significant temporal redundancy, imposing substantial memory and computational burdens on resource constrained AR hardware. To address this challenge, we introduce UTOPI, a plug-and-play pre-compression module designed specifically for egocentric long videos on AR platforms. First, we leverage user motion signals to estimate inter-frame overlap and propose a viewpoint-shift-invariant pruning algorithm. Second, we exploit eye-tracking sensors to identify user fixations, enabling the separation of attended foreground content from background and its preferential retention via a fine-tuned neural network-based adjustment mechanism. Across multiple benchmarks and model backbones, UTOPI achieves up to 95% compression while preserving performance.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 6 reviews · OpenReview
Updated 25 Nov 2026, 03:44 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
Initially, this paper has received 1 accept and 2 borderline reject recommendations from reviewers. The reviewers praised the paper for its strong motivation; solid technical execution; and six backbones tested across 3 benchmarks. However, the reviewers also had a number of issues with the paper in its current form:
- Issues with benchmark validity of egoeye and gaze estimation/gaze availability on EgoSchema/Ego4D and the method's robustness to this
- Limited novelty in individual components (e.g. gaze based attention, 2D gaussian kernels, IVOC, etc.)
- Missing generalisation to longer videos
- No statistical analysis as to the consistency of the performance increase - all results are a single run.
The AC has read the reviews and the paper and agrees with the majority of reviewers at this stage that the paper is not yet ready for publication, particularly because of the issues above. Because of this, the AC is currently leaning towards rejection for this paper, but is looking forward to seeing the above issues (and other issues the reviewers highlighted) addressed within the rebuttal.
Final justification
As mentioned above, this paper initially received 1 accept and 2 borderline reject recommendations from reviewers. The reviewers praised the paper for its strong motivation; solid technical execution; and six backbones tested across 3 benchmarks. However, the reviewers also had a number of issues with the paper in its current form:
- Issues with benchmark validity of egoeye and gaze estimation/gaze availability on EgoSchema/Ego4D and the method's robustness to this
- Limited novelty in individual components (e.g. gaze based attention, 2D gaussian kernels, IVOC, etc.)
- Missing generalisation to longer videos
- No statistical analysis as to the consistency of the performance increase - all results are a single run.
The rebuttal focused on addressing the reviewers' weaknesses and questions, particularly EgoEye benchmark construction; Gaze signals in EgoSchema/Ego4D; beyond pairwise consecutive frames; application on larger models; limited novelty; analysis of failure modes; limited scale benchmark; generalisation to longer videos; missing simpler baselines; statistical relevance over multiple runs; discrepancies between budget and accuracy; and human verification of QA benchmark.
Following the rebuttal 1 reviewer increased from borderline reject to borderline accept and 1 reviewer decreased from borderline reject to reject, giving the final scores of accept, borderline accept, and reject. PvZF mentioned in their final justification that they are still worried about how the central claim around long-video AR understanding is not sufficiently validated from the results in the original submission or the rebuttal. The AC has read the reviews, the paper, and the rebuttal, and agrees with the majority of the reviewers. Whilst the paper does not evaluate on videos beyond an hour in length, the EgoEye dataset does include videos up to 22 minutes in duration, well beyond short video datasets. Additionally, experiments that showcase the reduced budget are promising which, whilst not exactly showing how the method would scale to long video, does a reasonable approximation of a higher budget on a longer video. Because of these reasons, the AC recommends acceptance for this paper.
Read meta-review
Meta-review
Initially, this paper has received 1 accept and 2 borderline reject recommendations from reviewers. The reviewers praised the paper for its strong motivation; solid technical execution; and six backbones tested across 3 benchmarks. However, the reviewers also had a number of issues with the paper in its current form:
- Issues with benchmark validity of egoeye and gaze estimation/gaze availability on EgoSchema/Ego4D and the method's robustness to this
- Limited novelty in individual components (e.g. gaze based attention, 2D gaussian kernels, IVOC, etc.)
- Missing generalisation to longer videos
- No statistical analysis as to the consistency of the performance increase - all results are a single run.
The AC has read the reviews and the paper and agrees with the majority of reviewers at this stage that the paper is not yet ready for publication, particularly because of the issues above. Because of this, the AC is currently leaning towards rejection for this paper, but is looking forward to seeing the above issues (and other issues the reviewers highlighted) addressed within the rebuttal.
Final justification
As mentioned above, this paper initially received 1 accept and 2 borderline reject recommendations from reviewers. The reviewers praised the paper for its strong motivation; solid technical execution; and six backbones tested across 3 benchmarks. However, the reviewers also had a number of issues with the paper in its current form:
- Issues with benchmark validity of egoeye and gaze estimation/gaze availability on EgoSchema/Ego4D and the method's robustness to this
- Limited novelty in individual components (e.g. gaze based attention, 2D gaussian kernels, IVOC, etc.)
- Missing generalisation to longer videos
- No statistical analysis as to the consistency of the performance increase - all results are a single run.
The rebuttal focused on addressing the reviewers' weaknesses and questions, particularly EgoEye benchmark construction; Gaze signals in EgoSchema/Ego4D; beyond pairwise consecutive frames; application on larger models; limited novelty; analysis of failure modes; limited scale benchmark; generalisation to longer videos; missing simpler baselines; statistical relevance over multiple runs; discrepancies between budget and accuracy; and human verification of QA benchmark.
Following the rebuttal 1 reviewer increased from borderline reject to borderline accept and 1 reviewer decreased from borderline reject to reject, giving the final scores of accept, borderline accept, and reject. PvZF mentioned in their final justification that they are still worried about how the central claim around long-video AR understanding is not sufficiently validated from the results in the original submission or the rebuttal. The AC has read the reviews, the paper, and the rebuttal, and agrees with the majority of the reviewers. Whilst the paper does not evaluate on videos beyond an hour in length, the EgoEye dataset does include videos up to 22 minutes in duration, well beyond short video datasets. Additionally, experiments that showcase the reduced budget are promising which, whilst not exactly showing how the method would scale to long video, does a reasonable approximation of a higher budget on a longer video. Because of these reasons, the AC recommends acceptance for this paper.
1 comment
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
UTOPI is a plug-and-play module that compresses visual tokens for long-video understanding on resource-limited AR devices, using gaze (eye-tracking) to keep attended regions and IMU motion data to remove redundant overlap across frames, all before any query, so results can be cached and reused. It reportedly achieves up to ~95% token compression while maintaining or improving accuracy across three benchmarks (including the authors' new EgoEye), with major memory and latency savings on edge hardware.
Strengths and weaknesses
Strengths
-
It reuses signals AR devices already capture, gaze and IMU pose, instead of adding costly steps like optical flow. Gaze handles spatial redundancy, IMU handles temporal, which is a clean split.
-
Compression happens before any question, so the tokens live in the KV cache and get reused across queries. Query conditioned methods like DynTok and Q Frame have to reprocess the video each time.
-
Six backbones, three benchmarks, and actual system metrics (memory, TTFT, throughput) on both an A6000 and a Jetson Orin edge device. Gains are strong: up to 95% compression, about 52% less memory, roughly 1.9 times latency and 2.7 times throughput.
-
They separate AGTS from IVOC and test robustness to gaze noise, motion intensity, missing gaze (SUM predicted, under 1.2% drop), and object to gaze distance.
-
The straight through estimator makes the hard token selection trainable, which sets it apart from fixed zero shot gaze crop baselines.
Weaknesses
-
All results are single run (item 7 admits this). Several headline gains are only 1 to 3%, so it is hard to tell which are real.
-
The saliency MLP is tuned on EgoEye QA pairs, and EgoEye is also a main eval set, so they share a gaze centric bias that favors the method. The QA is VLM generated (circularity risk), and it is built from just 46 videos.
-
On EgoEye, Qwen actually dips below baseline at most budgets. The EgoSchema gains may just come from pruning noisy distractors, which the authors admit, so "compression helps" is oversold.
-
IVOC needs depth; when it is missing they use MegaSaM estimates, with no analysis of how pose or depth error affects compression. Real AR tracking drifts, and the clean signal tests do not stress that.
-
Everything runs on a Jetson standing in for an HMD, no live streaming, so real time end to end behavior is unverified (the authors concede this).
-
PruneVid's KV cache module is disabled due to reimplementation issues, so that comparison is not apples to apples.
Questions
-
All results are single-run (per your checklist). Report mean ± std over ≥3 seeds for the 15% rows of Table 1 and for Table 4. Score rises if margins exceed the noise band; falls if they don't.
-
The saliency MLP is tuned on EgoEye, which is also an eval benchmark. (a) Confirm the split is disjoint at the video level. (b) Tune on EgoSchema, test on EgoEye (and vice versa). Score rises on strong cross-benchmark transfer; falls if it overfits.
-
IVOC depends on IMU pose and depth, but only clean signals are tested. Repeat your gaze-noise study (Table 6) with injected pose/depth noise. Score rises on graceful degradation; falls on sharp sensitivity.
-
On EgoEye, UTOPI is below baseline at 30%/50% budgets but above at 15%. Why does a higher budget give lower accuracy, and are the EgoSchema gains just distractor removal on a noisy benchmark? Score rises with a convincing mechanism; falls if the headline claim is unsupported.
-
EgoEye = 46 videos with VLM-generated QA. Report the human-verified fraction, human-vs-VLM agreement, and % discarded in QC. Score rises with solid label quality; falls if unverified.
Limitations
yes
Final justification
My concerns and questions have been satisfactorily clarified by the authors, and I am accordingly raising my score to positive.
Formatting concerns
None
5 comments
Response to Question 1 and Question 2
Q1: All results are single-run (per your checklist). Report mean ± std over ≥3 seeds for the 15% rows of Table 1 and for Table 4. Score rises if margins exceed the noise band; falls if they don't.
A: We thank the reviewer for this suggestion. We first clarify where randomness enters UTOPI. The only trained and only stochastic component is the saliency predictor in AGTS, a lightweight MLP whose training involves (i) random parameter initialization, (ii) the random draw of calibration QA pairs, and (iii) stochastic token dropping during training. IVOC and all inference-time computation are deterministic, with greedy decoding throughout. We therefore retrained the saliency predictor with 3 additional independent seeds, where each seed jointly controls all three sources of randomness above, and re-evaluated the pipeline with each retrained predictor under an identical, fixed evaluation protocol. Together with the originally reported run, this gives 4 runs per benchmark. All other rows contain no trained component; they are deterministic single-run values and are reported unchanged.
15% rows of Table 1, mean ± std over 4 runs:
Method Token Budget EE ES EGV QWen2.5VL-7B 100% 58.4% 60.1% 47.8% w/ UTOPI (ours) 15% 60.1% ± 0.77% 64.8% ± 0.22% 49.1% ± 0.26% w/ DTD 15% 57.6% 64.5% 47.9% w/ PruneVid 15% 51.3% 63.0% 48.8% w/ Random Drop 15% 56.8% 59.3% 46.1% The margins over the strongest baseline exceed the seed noise band on all three benchmarks: on EE the margin is +2.5% against a band of ±0.77%; on ES the margin is +0.3% against ±0.22%; on EGV it is +0.3% against ±0.26%. Moreover, every individual run on every benchmark stays above the uncompressed 100% baseline while using 15% of the visual tokens.
Table 4, mean ± std over 4 runs for the AGTS-enabled configurations:
AGTS IVOC Token Budget ES ✓ ✓ 15% 64.8% ± 0.26% ✓ × 50% 64.1% ± 0.17% × ✓ 30% 64.4% × × 100% 60.1% Configurations without AGTS contain no trained component and are fully deterministic, hence keep single values. Both AGTS-enabled configurations exceed the no-compression baseline by about 4 points for every individual seed, which is more than 15 times the noise band. The full combination with both modules enabled exceeds the strongest single-module configuration, IVOC only at 64.4%, by 0.4% against a band of ±0.26%. Beyond this accuracy delta, the combination's primary contribution is that it is the only configuration to reach the lowest budget of 15% without degradation. We will include these seed-variance results in the revision.
Q2: The saliency MLP is tuned on EgoEye, which is also an eval benchmark. (a) Confirm the split is disjoint at the video level. (b) Tune on EgoSchema, test on EgoEye (and vice versa). Score rises on strong cross-benchmark transfer; falls if it overfits.
A: We thank the reviewer for this suggestion. For (a), the split is disjoint at the video level: the 2k calibration QA pairs are drawn from 18 videos, and evaluation uses only QA pairs from the remaining 28 videos, so the MLP never sees any frame of an evaluation video during training. We will make this explicit in Sec. 4.1.
For (b), the direction "tune on EgoSchema" is infeasible in a meaningful form: calibration requires ground-truth gaze aligned with QA, and EgoSchema releases no gaze modality. Training with SUM-predicted gaze would supervise one predictor with another, which is circular. The forward direction, however, is already tested in Table 1. The MLP is calibrated only on EgoEye, as stated in Secs. 3.2 and 4.1, so every EgoSchema and EgoGazeVQA number is zero-shot cross-benchmark transfer: identical weights, entirely different source videos, devices, wearers, and activities. UTOPI still improves over the uncompressed baselines, 64.8% versus 60.1% on ES and 49.0% versus 47.8% on EGV.
Response to Questions 3-5
Q3: IVOC depends on IMU pose and depth, but only clean signals are tested. Repeat your gaze-noise study (Table 6) with injected pose/depth noise. Score rises on graceful degradation; falls on sharp sensitivity.
A: We thank the reviewer for this suggestion. We repeated the Table 6 protocol with injected IMU rotation drift between consecutive frames at the 15% budget. As in all experiments, θ and ρ are adaptively adjusted to hold the token budget fixed, which is why the compression column stays constant:
Perturbation EE Acc. Achieved compression Clean 60.6% 15% IMU rotation drift 1° 60.1% 15% IMU rotation drift 2° 59.5% 15% IMU rotation drift 5° 56.4% 15% Accuracy degrades smoothly: it drops by 0.5% at 1°, by 1.1% at 2°, and by 4.2% even at 5°, where it remains comparable to clean-signal Random Drop at 56.8%. These are per-frame-pair errors. Our pipeline samples a fixed number of frames per video, so in our benchmarks two consecutive sampled frames are at most about one second apart.
The robustness has a structural reason: IVOC merges a token only if, after reprojection, its cosine similarity with the corresponding token exceeds θ, as defined in Eqs. 4–5. With a fixed θ, pose error produces wrong correspondences that fail this test, so affected tokens are kept rather than wrongly deleted. Error converts into reduced compression, not lost content.
Q4: On EgoEye, UTOPI is below baseline at 30%/50% budgets but above at 15%. Why does a higher budget give lower accuracy, and are the EgoSchema gains just distractor removal on a noisy benchmark? Score rises with a convincing mechanism; falls if the headline claim is unsupported.
A: We thank the reviewer for this suggestion. We would like to address this question with three observations drawn from Table 1.
First, the mid-budget dip is not specific to UTOPI. At 30% and 50%, every compression method falls below the EE baseline of 58.4%; at 50%, for example, DTD reaches 57.0%, PruneVid 52.4%, Random Drop 56.4%, and UTOPI 57.1%. The only configuration exceeding the baseline on EE is UTOPI at 15%. The dip therefore reflects a general property of partial token removal on this benchmark, and crossing the baseline requires selection that is both aggressive and informed.
Second, the budget trend is consistent across benchmarks. For UTOPI, accuracy rises monotonically as the budget shrinks on all three: from 61.9% to 62.6% to 64.8% on ES, from 48.5% to 48.7% to 49.0% on EGV, and from 57.1% to 57.4% to 60.6% on EE. Our working explanation is that mid-saliency background tokens carry little answer-relevant information yet still compete for attention. A 30% to 50% budget retains much of this interference, whereas at 15% only high-confidence foreground survives, maximizing the signal-to-noise ratio of the visual context.
Third, the ES gains are not "any pruning helps on a noisy benchmark." Random Drop at 15% actually hurts ES, scoring 59.3% against the 60.1% baseline. If the gains came from pruning per se, random pruning would also gain. Only informed selection gains: UTOPI by 4.7%, DTD by 4.4%, and PruneVid by 2.9%.
Q5: EgoEye = 46 videos with VLM-generated QA. Report the human-verified fraction, human-vs-VLM agreement, and % discarded in QC. Score rises with solid label quality; falls if unverified.
A: We thank the reviewer for this suggestion. The QA pairs are not accepted from the VLM automatically. Every released pair passed the multi-stage internal QC noted in Checklist items 14–15, whose statistics we report here and will document in the appendix.
- Human-verified fraction: 100%. All released QA pairs were human-reviewed. Crucially, reviewers answered each question from the five options without access to the generated answer, so verification is blind rather than confirmatory.
- Discard rates. Before human review, candidates pass through rule-based screening, which removes unsuitable question targets such as walls or the wearer's own body, and through LLM blind filtering, which keeps only the questions an LLM answers incorrectly without seeing the video and thereby eliminates items solvable from language priors alone. Together these two filters accept about 50% of candidates. At the human-review stage, the adoption rate is about 70%, i.e., a further 30% of candidates are discarded.
- Human-vs-VLM agreement: 83.5%. Under blind answering, human accuracy on the released benchmark averages 83.5%, well above the roughly 60% achieved by the strongest evaluated models, confirming that the questions are both answerable and discriminative.
We also note that the benchmark's diversity exceeds what "46 videos" suggests: it covers over 2k distinct question subjects across five question categories, drawn from two independently collected datasets, AEA and Nymeria, with video durations of 50 seconds to 5 minutes.
Response to Weaknesses
W1: All results are single run (item 7 admits this). Several headline gains are only 1 to 3%, so it is hard to tell which are real.
A: Please see our response to Q1.
W2: The saliency MLP is tuned on EgoEye QA pairs, and EgoEye is also a main eval set, so they share a gaze centric bias that favors the method. The QA is VLM generated (circularity risk), and it is built from just 46 videos.
A: Please see our responses to Q2 and Q5.
W3: On EgoEye, Qwen actually dips below baseline at most budgets. The EgoSchema gains may just come from pruning noisy distractors, which the authors admit, so "compression helps" is oversold.
A: Please see our response to Q4.
W4: IVOC needs depth; when it is missing they use MegaSaM estimates, with no analysis of how pose or depth error affects compression. Real AR tracking drifts, and the clean signal tests do not stress that.
A: Please see our response to Q3.
W5: Everything runs on a Jetson standing in for an HMD, no live streaming, so real time end to end behavior is unverified (the authors concede this).
A: We thank the reviewer for this comment. We concede this, as already acknowledged in the paper. Jetson Orin shares the SoC class and unified-memory architecture of current standalone XR devices and is the standard proxy for on-device feasibility. UTOPI's design itself is streaming-compatible: AGTS operates per frame and IVOC touches only consecutive frames, so the per-frame cost stays constant regardless of video length. A live end-to-end HMD deployment is future work, and we will state this explicitly in the revision.
W6: PruneVid's KV cache module is disabled due to reimplementation issues, so that comparison is not apples to apples.
A: We thank the reviewer for this comment. It was disabled because the implementation is not public and requires modifying the backbone, as stated in Sec. 4.1; we will add this caveat to the Table 1 caption. The comparison remains informative for what we evaluate, since both methods act as pre-LLM token selectors under identical token budgets. In contrast, KV-cache compression operates downstream on the cache, addresses a different stage of the pipeline, and could equally be stacked on UTOPI.
- Rating
- 2/6
- Confidence
- 5/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes UTOPI, a plug-and-play token pre-compression module for efficient long-video understanding on memory-constrained AR devices. The method uses AR-native signals—gaze tracking and IMU-based pose estimation—to compress visual tokens before VLM processing, achieving up to 95% compression while maintaining accuracy. The authors also introduce EgoEye, a new egocentric video QA benchmark centered on human attention patterns.
Strengths and weaknesses
Strengths:
-
Pragmatic problem framing. AR devices have real constraints: 8-16GB memory shared between CPU and GPU. Processing long egocentric video through VLMs like QWen2.5VL requires tens of gigabytes. This paper doesn't just propose a method—it solves a deployment bottleneck that practitioners actually care about.
-
Clever exploitation of available signals. Rather than treating compression as generic token selection, UTOPI leverages AR-native inputs: eye gaze (which modern headsets provide) and IMU pose estimation (already on the device). This is smart because it's already captured, unlike optical flow or other computed features. Using gaze to identify attended regions is well-motivated by attention research—the paper correctly notes that humans focus on small regions while the periphery has low informational value.
-
Solid technical execution with two complementary components. The AGTS module (gaze-aware token selection with Gaussian kernel + saliency predictor) is straightforward but effective. The IVOC module (inter-frame view overlap compression) is more innovative—using IMU and camera pose to project overlapping regions between frames and remove redundant tokens. This handles temporal redundancy in a way that respects egocentric video structure (head movements, not scene pans).
-
Comprehensive experimental evaluation. The paper tests on three video QA benchmarks (EgoSchema, EgoGazeVQA, EgoEye) with multiple VLM backbones (QWen2.5VL, MindPalace, PLLaVA). The ablations are thorough: Table 3 breaks down AGTS vs. IVOC contributions, Table 4 evaluates different budget tradeoffs. Memory and latency measurements on real hardware (RTX A6000, Jetson Orin NX) are appreciated—not just theoretical speedups.
-
Strong empirical results. At 15% token budget, UTOPI retains 96%+ baseline accuracy on EgoSchema while using only 15% of tokens. Memory reduction of 52.2% with maintained accuracy is substantial. Latency improvements of 1.92×-2.67× on edge hardware are practically significant.
-
Realistic benchmark contribution. EgoEye addresses a real gap: existing LVU benchmarks focus on generic video QA, not human-centric attention-driven understanding. With 5k+ QA pairs grounded in real gaze traces, this is a useful resource for the community.
Weaknesses:
-
Limited novelty in individual components. Gaze-based attention is well-established in vision research (papers cited: [32], [51], [82], [83]). Using 2D Gaussian kernels around gaze points is standard. The saliency predictor is just an MLP on token embeddings. IVOC relies on commodity IMU + camera pose estimation (not novel)—the k-means clustering and surrogate token selection is standard. The core contribution is combining these in the AR context, not inventing fundamentally new techniques.
-
Insufficient analysis of failure modes. When does gaze-aware selection fail? What if users have peripheral vision attention (musicians reading sheet music, drivers watching mirrors)? What if the AR device's gaze tracker is noisy or miscalibrated? The paper doesn't evaluate robustness to gaze noise or discuss when gaze-based selection might harm performance. A user study or gaze perturbation analysis would strengthen claims.
-
EgoEye benchmark has limited scale and unclear generalization. 5k QA pairs sounds like a lot, but it's constructed from only two datasets (Aria Everyday Activities, Nymeria) and two question subjects ("Paper Tower," "Washing Machine Knobs"). Will queries on these specific objects generalize to other egocentric tasks? The paper doesn't test cross-domain generalization (e.g., train on Paper Tower, test on Washing Machine). Without this, it's unclear if EgoEye tests diverse reasoning or just memorization of these two tasks.
-
Gaze data availability is a practical limitation that's undersold. Not all AR devices have high-quality eye tracking. Meta Quest Pro, Apple Vision Pro, and HoloLens 2 have gaze, but older devices don't. The paper briefly mentions SUM estimation (Spatial Uncertainty Maps) as a fallback for devices without gaze but doesn't benchmark this. If gaze is unavailable, does accuracy drop significantly? How much worse is SUM-based selection compared to true gaze? This is critical for adoption.
-
Straight-through estimator (STE) for gradient approximation is mathematically hand-wavy. Equation 3 approximates ∂T_F/∂α_s as a product of attention weights and token embeddings. The authors acknowledge this is "non-differentiable" and use STE, but don't justify why this particular approximation is valid. Why not use Gumbel-softmax or other differentiable approximations? No ablation comparing STE to alternatives. This feels like a pragmatic hack rather than principled design.
-
Generalization to longer videos not demonstrated. All experiments use frame budgets of 15-50% of original tokens, which translates to roughly 50-150 frames of 300 sampled frames. Real AR assistants might need to understand 10+ minute videos. Does memory scale linearly? Does UTOPI's effectiveness degrade as videos get longer and temporal overlap becomes less informative? Unknown.
-
Inter-frame overlap compression assumes smooth head motion. IVOC relies on IMU pose estimates to project tokens between consecutive frames. If the user's head moves erratically or the IMU drifts, the projection becomes inaccurate and overlap estimation fails. The paper doesn't analyze IMU calibration requirements or quantify how pose drift affects compression. This is a practical concern for deployed systems.
-
Missing comparison to simpler baselines. The paper compares to PruneVid, DTD, MindPalace, and random dropping. But why not compare to standard query-agnostic methods like uniform downsampling or keyframe selection (every Nth frame)? It's possible that just taking every 5th frame might achieve 80% of UTOPI's benefits with zero gaze instrumentation. Without this baseline, we don't know if the complexity of gaze-aware selection is actually necessary.
-
Evaluation protocol has a subtle issue. Table 1 marks some token budgets as "†" indicating "blind test" (no video input, only QA options). But UTOPI uses gaze/IMU signals derived from watching the full video. If the model only sees QA options, can it even use the compressed tokens effectively? The paper acknowledges this but doesn't clearly separate blind vs. non-blind results, making it hard to assess real-world applicability.
Questions
Q1: How critical is gaze availability? Your paper targets AR devices with eye tracking, but not all headsets have this (older Meta Quest, some enterprise devices). You briefly mention SUM (Spatial Uncertainty Maps) as a fallback but provide no quantitative evaluation. Please compare: (a) gaze-based selection, (b) SUM-based selection, (c) uniform downsampling baseline. This shows whether gaze instrumentation is necessary or optional, and how much accuracy degrades without it. This would clarify the practical applicability of UTOPI beyond premium devices.
Q2: Can you include a simple downsampling baseline? Your comparisons are against PruneVid, DTD, MindPalace, and random dropping. But the simplest baseline—uniform frame downsampling (every 5th frame, no gaze, no compression)—is missing. It's possible that taking every Nth frame achieves 80% of UTOPI's gains with zero gaze instrumentation. Please benchmark: UTOPI at 15% budget vs. uniform downsampling at 15% budget. This would show whether gaze-aware selection is fundamentally better or just a modest improvement over trivial baselines.
Q3: Does your saliency predictor generalize across datasets? You fine-tune the MLP on EgoEye (2k QA pairs). How much does performance depend on this dataset-specific predictor? Please report: (a) saliency predictor trained on EgoEye, tested on EgoSchema/EgoGazeVQA; (b) predictor trained on EgoSchema, tested on EgoEye (if you have time). This clarifies whether the predictor learns general attention patterns or overfits to EgoEye's specific tasks (Paper Tower, Washing Machine).
Q4: Why straight-through estimators over alternatives? Equation 3 uses STE to approximate non-differentiable gate operations. Why not Gumbel-softmax, continuous relaxations, or other differentiable approximations? Please provide an ablation: STE vs. Gumbel-softmax vs. at least one other method, measured on one benchmark (EgoSchema). This justifies a core technical choice that currently feels like an unmotivated pragmatic hack.
Q5: How robust is UTOPI to gaze tracker noise? Real gaze trackers have noise (~0.5-2° error depending on device). Please perturb gaze coordinates with Gaussian noise (σ = 0.5°, 1°, 2°) and report accuracy degradation. What noise level breaks UTOPI? This shows whether gaze-based compression is practically viable on consumer hardware with imperfect trackers.
Limitations
Partially addressed. The paper acknowledges resource constraints on AR devices and briefly mentions SUM as a fallback for devices without gaze. However, several critical limitations lack depth:
- Gaze availability is undersold: Not all AR devices have eye tracking; the implications for broader adoption are not discussed.
- No robustness analysis: Gaze tracker noise, IMU drift, and pose estimation errors are not evaluated—these affect real deployments.
- EgoEye is narrow: Two datasets, two question subjects. Will the benchmark generalize to new domains? Unknown.
- Long-video scalability untested: All experiments use 15-50% of sampled frames (roughly 50-150 frames total). How does UTOPI perform on 5-10 minute videos?
Final justification
The rebuttal addresses few of my concerns through additional statistical and robustness analyses. However, I remain concerned that the central claim around long-video AR understanding is not sufficiently validated on genuinely long-duration continuous videos. The current evaluation and fixed-frame sampling setup do not fully demonstrate how accuracy and information retention behave as video duration increases. Given that long-video scalability is a core motivation of the work, I consider this remaining empirical gap significant.
Formatting concerns
- Implementation Details Scattered Hyperparameters like K = 0.02 × |T_S|, ρ (threshold for Eq. 2), and σ (Gaussian kernel std) are mentioned inline in Section 3 Suggestion: Consolidate into a single "Implementation Details" or "Hyperparameter Settings" table in appendix for clarity and reproducibility
- Algorithm Descriptions The paper references multi-stage pipelines (AGTS, IVOC, IVOC clustering) but doesn't always present pseudocode Suggestion: Consider Algorithm boxes for AGTS token selection and IVOC compression pipeline in main paper or clearly referenced appendix
- Table Formatting Tables 1-4 are well-formatted with clear captions Some tables lack error bars/confidence intervals (noted in review) Note: This is a content issue (missing statistics), not a formatting violation
- Figure Captions Captions are present but some are quite long (Figure 1 caption: 4+ lines) NeurIPS 2026 expectation: Captions should be concise; detailed explanation can go in text Minor suggestion: Shorten captions where possible
7 comments
Response to Questions 1-3
Q1: How critical is gaze availability? Your paper targets AR devices with eye tracking, but not all headsets have this (older Meta Quest, some enterprise devices). You briefly mention SUM (Spatial Uncertainty Maps) as a fallback but provide no quantitative evaluation. Please compare: (a) gaze-based selection, (b) SUM-based selection, (c) uniform downsampling baseline. This shows whether gaze instrumentation is necessary or optional, and how much accuracy degrades without it. This would clarify the practical applicability of UTOPI beyond premium devices.
A: Thank you for your comment and suggestions. All three comparisons exist in the paper. We consolidate them below on EgoEye at the 15% budget, where ground-truth Aria eye-tracking is available:
Selection signal EE Acc. (a) Ground-truth gaze (UTOPI) 60.6% (Table 1) (b) SUM-predicted gaze (UTOPI) 59.4% (Sec. 4.4) (c) Uniform resolution downsampling 50.4% (Table 1, 15%†) Uncompressed baseline 58.4% (b) costs only 1.2% relative to (a) and still exceeds the uncompressed baseline, while (c) trails by 10.2%. Gaze instrumentation is therefore optional. In fact, our EgoSchema results already operate in the no-eye-tracker regime: EgoSchema releases no gaze modality, and 99.7% of its source videos rely on SUM-predicted gaze, yet UTOPI still improves over the baseline there, 64.8% versus 60.1%. Real eye tracking, where present, is strictly better. We will state this prominently in the revision. We would also like to clarify that SUM stands for Saliency Unification through Mamba [27], a visual saliency predictor, rather than Spatial Uncertainty Maps.
Q2: Can you include a simple downsampling baseline? Your comparisons are against PruneVid, DTD, MindPalace, and random dropping. But the simplest baseline—uniform frame downsampling (every 5th frame, no gaze, no compression)—is missing. It's possible that taking every Nth frame achieves 80% of UTOPI's gains with zero gaze instrumentation. Please benchmark: UTOPI at 15% budget vs. uniform downsampling at 15% budget. This would show whether gaze-aware selection is fundamentally better or just a modest improvement over trivial baselines.
A: Thank you for your comment and suggestions. We have run this baseline. It keeps roughly every 7th of the 300 sampled frames, uses no gaze signal and applies no further compression, and matches the same 15% token budget as UTOPI:
Method (15%) EE ES EGV Uniform frame sampling 48.8% 50.3% 44.6% Random token drop 56.8% 59.3% 46.1% Resolution downsampling 50.4% 53.8% 44.2% UTOPI 60.6% 64.8% 49.0% It underperforms UTOPI by 10.2% on average: 11.8% on EE, 14.5% on ES, and 4.4% on EGV. Rather than reaching 80% of UTOPI's gains, it captures none of them. Uniform sampling falls below even the uncompressed baseline on all three benchmarks, by 9.6%, 9.8%, and 3.2% respectively, where UTOPI improves by 2.2%, 4.7%, and 1.2%. It also falls below random token dropping. The reason is structural. Dropping entire frames sacrifices temporal coverage, so short-lived hand–object interactions occurring between the kept frames are lost entirely, whereas UTOPI keeps the temporal structure of all 300 frames and instead removes redundancy within and across frames.
Q3: Does your saliency predictor generalize across datasets? You fine-tune the MLP on EgoEye (2k QA pairs). How much does performance depend on this dataset-specific predictor? Please report: (a) saliency predictor trained on EgoEye, tested on EgoSchema/EgoGazeVQA; (b) predictor trained on EgoSchema, tested on EgoEye (if you have time). This clarifies whether the predictor learns general attention patterns or overfits to EgoEye's specific tasks (Paper Tower, Washing Machine).
A: Thank you for your comment and suggestions. (a) is already reported in Table 1. The MLP is calibrated only on EgoEye, as stated in Secs. 3.2 and 4.1, so every ES/EGV number is zero-shot transfer: identical weights, no retraining, and entirely different source videos, devices, and activities. UTOPI still improves over the uncompressed baselines on both, 64.8% versus 60.1% on ES and 49.0% versus 47.8% on EGV. The MLP scores individual token embeddings and receives no task or dataset identity. We would also like to clarify that "Paper Tower" and "Washing Machine Knob" are two examples shown in Figure 5. As described in Sec. 4.1, EgoEye contains more than 2k question subjects in total; please see our response to W.3 for details.
(b) is infeasible in a meaningful form: calibration requires ground-truth gaze aligned with QA, and EgoSchema provides no gaze modality. Please see our response to Reviewer jA94 Q.2 for details.
Response to Question 4 and Question 5
Q4: Why straight-through estimators over alternatives? Equation 3 uses STE to approximate non-differentiable gate operations. Why not Gumbel-softmax, continuous relaxations, or other differentiable approximations? Please provide an ablation: STE vs. Gumbel-softmax vs. at least one other method, measured on one benchmark (EgoSchema). This justifies a core technical choice that currently feels like an unmotivated pragmatic hack.
A: Thank you for your comment and suggestions. We did evaluate Gumbel-softmax during early development, and it performed essentially the same as STE: on EgoSchema at 15% budget, straight-through Gumbel-softmax training reached 64.1% vs. 64.8% for STE. We retained STE for two reasons.
First, train–test consistency with minimal machinery. At inference the gate is a hard threshold, as defined in Eq. 2. STE keeps the forward pass hard during training, so the network being trained is exactly the network being deployed, and only the backward pass is approximated. The straight-through Gumbel variant shares this same backward approximation and differs from STE only by injected sampling noise and a temperature schedule, which is consistent with the near-identical accuracy we observed. Fully soft relaxations, by contrast, feed soft token mixtures forward, creating a train–test mismatch with hard inference; prior work on differentiable selection reports that straight-through training with a hard forward pass consistently outperforms such soft variants [R1], so we did not pursue them. Second, our recipe already supplies the exploration benefit that Gumbel noise provides: as described in Sec. 4.1, gate values are interpreted as probabilities for stochastic token dropping under a scheduled drop ratio with temperature annealing, regularizing the predictor without Gumbel's additional hyperparameters.
This is also consistent with the broader literature, where both estimators are standard for learned token selection: DynamicViT [R2] trains with Gumbel-softmax and thresholds at inference, while quantization and token-pruning methods widely adopt plain STE. This indicates the choice is not performance-critical for this task. We will add this justification and the comparison to the paper.
[R1] Herrmann et al., "Channel selection using Gumbel Softmax," ECCV 2020.
[R2] Rao et al., "DynamicViT: Efficient Vision Transformers with Dynamic Token Sparsification," NeurIPS 2021.
Q5: How robust is UTOPI to gaze tracker noise? Real gaze trackers have noise (~0.5-2° error depending on device). Please perturb gaze coordinates with Gaussian noise (σ = 0.5°, 1°, 2°) and report accuracy degradation. What noise level breaks UTOPI? This shows whether gaze-based compression is practically viable on consumer hardware with imperfect trackers.
A: Thank you for your comment and suggestions. This study is in the paper: Table 6 perturbs the gaze locations with 75 to 300 px of noise. For reference, EgoEye frames are 1408×1408 pixels and the Aria RGB camera covers a field of view of about 110°, one degree of visual angle spans roughly 12.8 pixels. The requested σ of 0.5°, 1°, and 2° therefore corresponds to about 6, 13, and 26 px, all below our smallest tested perturbation. At 75 px, which is about 6° and already 3 to 12 times the error of consumer trackers, accuracy drops by only 0.3%, from 60.6% to 60.3% on EE. Even at 300 px, which is about 23°, the drop is 2.9% on EE and 1.9% on EGV. We will add this pixel-to-degree conversion to the Table 6 caption in the revision.
Response to Weaknesses 1-5
W1: Limited novelty in individual components. Gaze-based attention is well-established in vision research (papers cited: [32], [51], [82], [83]). Using 2D Gaussian kernels around gaze points is standard. The saliency predictor is just an MLP on token embeddings. IVOC relies on commodity IMU + camera pose estimation (not novel)—the k-means clustering and surrogate token selection is standard. The core contribution is combining these in the AR context, not inventing fundamentally new techniques.
A: Thank you for your comment and suggestions. We would assess the contribution at the system level, consistent with the reviewer's own Strengths 2 and 3, which describe these designs as "clever" and "more innovative". The pairing of free AR-native signals with egocentric token redundancy is new. The way IVOC establishes token correspondence is also new to the token compression literature: it first reprojects tokens across frames geometrically and then verifies each candidate match by feature similarity. Component simplicity is a design constraint rather than a capability ceiling: the whole module must run within a millisecond-scale budget on device, 673 ms as reported in Table 2.
W2: Insufficient analysis of failure modes. When does gaze-aware selection fail? What if users have peripheral vision attention (musicians reading sheet music, drivers watching mirrors)? What if the AR device's gaze tracker is noisy or miscalibrated? The paper doesn't evaluate robustness to gaze noise or discuss when gaze-based selection might harm performance. A user study or gaze perturbation analysis would strengthen claims.
A: Thank you for your comment and suggestions. Gaze-noise robustness is evaluated in Table 6, as discussed in Q5. Sustained peripheral attention, as in the musician and driver examples, is a genuine limitation of the gaze prior: AGTS gates tokens by the product α·G, so regions far from fixation need very high predicted saliency to survive. Table 6 does suggest the behavior degrades gracefully, since even gaze misplaced by about 23° costs less than 3% accuracy. We agree this scenario deserves explicit treatment and will add the failure-mode discussion to the limitations.
W3: EgoEye benchmark has limited scale and unclear generalization. 5k QA pairs sounds like a lot, but it's constructed from only two datasets (Aria Everyday Activities, Nymeria) and two question subjects ("Paper Tower," "Washing Machine Knobs"). Will queries on these specific objects generalize to other egocentric tasks? The paper doesn't test cross-domain generalization (e.g., train on Paper Tower, test on Washing Machine). Without this, it's unclear if EgoEye tests diverse reasoning or just memorization of these two tasks.
A: Thank you for your comment and suggestions. We would like to clarify a possible misunderstanding here. EgoEye contains over 2k distinct question subjects, as stated in Sec. 4.1; "Paper Tower" and "Washing Machine Knobs" are simply two illustrative examples shown in the figures, not the full set. The 5k+ QA pairs span 46 videos drawn from two independently collected datasets, AEA and Nymeria, with durations ranging from 50 seconds to 5 minutes, and cover five question categories, with per-category results reported in Fig. 8 of the appendix. Cross-domain generalization of the method is shown on ES and EGV, as discussed in Q3.
W4: Gaze data availability is a practical limitation that's undersold. Not all AR devices have high-quality eye tracking. Meta Quest Pro, Apple Vision Pro, and HoloLens 2 have gaze, but older devices don't. The paper briefly mentions SUM estimation (Spatial Uncertainty Maps) as a fallback for devices without gaze but doesn't benchmark this. If gaze is unavailable, does accuracy drop significantly? How much worse is SUM-based selection compared to true gaze? This is critical for adoption.
A: Please see our response to Q1.
W5: Straight-through estimator (STE) for gradient approximation is mathematically hand-wavy. Equation 3 approximates ∂T_F/∂α_s as a product of attention weights and token embeddings. The authors acknowledge this is "non-differentiable" and use STE, but don't justify why this particular approximation is valid. Why not use Gumbel-softmax or other differentiable approximations? No ablation comparing STE to alternatives. This feels like a pragmatic hack rather than principled design.
A: Please see our response to Q4.
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper addresses very important aspect of temporal redundancy in egocentric video understanding by introducing UTOPI, a pre-compression module, where the system has two core components: (1) an Adaptive Gaze-Aware Token Selector (AGTS) that uses eye-tracking signals combined with a learned saliency predictor to retain spatially important tokens near the user's gaze, and (2) an Inter-Frame View Overlap Compressor (IVOC) that uses IMU-based pose estimation to identify and compress temporally redundant tokens across consecutive frames. They also provide EgoEye, which has attention driven QA pairs. They benchmark their method on EgoEye, EgoSchema, and EgoGazeQA to show the effectiveness (95% token compression while improving the baseline accuracy) of their approach.
This works addresses the central challenge of deploying memory and compute intensive VLMs on resource-constrained AR hardware.
Strengths and weaknesses
Strengths:
-
Well motivated problem formulation: The paper clearly motivates the gap between demands of long-video understanding and constraints of AR hardware by sharing observations that 32% of consecutive frames pairs show less than 9% pixel change. The use of AR-native sensor signals (gaze, IMU) rather than pure vision-base heuristics is natural and justified design choice.
-
Query-agnostic pre-compression: Unlike some previous methods, UTOPI doesn't need user query to select the user query ahead of time, which is more realistic setting in AR assistants
-
Strong empirical results with comprehensive evaluation: The experimental results are compelling at various token budget on Qwen2.5VL-7B, in fact improving by 2.7% on average over uncompressed baseline, suggesting that redundant token removal reduces noise. The ablations cleanly isolates the contributions of AGTS and IVOC.
-
Viewpoint-shift-invariant design: The insight that naive pixel-level compression fails for egocentric video due to head motion, and the use of geometric reproduction to establish inter-frame correspondence is technically sound and well-motivated, clear improvement over many other methods that do not account for viewpoint changes
Weaknesses:
-
EgoEye benchmark construction raises validity concerns: the saliency MLP is fine-tuned on 2K EgoEye samples, and they are all generated using VLM without manual review there may be distributional biases that favor fine-tuned model.
-
For EgoSchema and portions of Ego4D that lack gaze signals, the authors estimate gaze using SUM. The accuracy of SUM on Ego4D videos is unknown and could be substantially worse. This undermines the claim that UTOPI is specifically designed for AR-native signals.
-
IVOC only considers pairwise consecutive frames, which may miss the scenarios (which is very common in egocentric case) where user looks away and comes back to the same scene. Token redundancy may not be detected in such cases.
-
Though the work is targeted for resource constrained AR devices and the baseline benchmarking is done on 7B model, at least the discussion of applying this approach on the bigger models to see if the gains are similar or not - would have made the method contribution even stronger. The overall quality i.e. 50-60% accuracy, may not be acceptable for real world deployment quality bar.
Questions
Q.1 How does UTOPI perform on bigger models (e.g. Qwen3-VL-236B) or even some other small models (e.g. Qwen3-VL-4B) ? This will help understand if the gains are transferable for all size models.
Q.2 How does the MLP generalizes across datasets? if trained on EgoEye, does it transfer well to EgoSchema without retraining?
Limitations
Limitations that should be discussed:
-
Gaze estimation as a fallback: A significant portion of the evaluation relies on estimated rather than real gaze signals (via SUM for EgoSchema/Ego4D videos). The authors should explicitly discuss the gap between their AR-native framing and the reality that much of their evaluation uses non-AR data with predicted gaze.
-
Pairwise temporal compression: The IVOC module only compares consecutive frames. The authors should discuss the implications of this design choice, particularly for scenarios involving revisited scenes or large temporal gaps, and acknowledge the missed compression opportunities.
-
Domain generalization of the saliency MLP: The learned component is fine-tuned on EgoEye data. The authors should discuss whether this transfers to substantially different AR domains without retraining.
-
The paper's dismissal of societal impact as N/A is a missed opportunity: A system that continuously records egocentric video, tracks eye gaze, and builds episodic memory representations has clear privacy implications, both for the wearer and for bystanders captured in the video stream. Compressing and storing visual tokens of attended regions effectively creates a record of what the user found interesting or important. The authors should at minimum discuss this.
Formatting concerns
None
5 comments
Response to Questions
Q1: How does UTOPI perform on bigger models (e.g. Qwen3-VL-236B) or even some other small models (e.g. Qwen3-VL-4B)? This will help understand if the gains are transferable for all size models.
A: Thank you for your comment and suggestions. For smaller models, the performance is already evaluated. UTOPI is applied to 4-bit Qwen2.5VL-7B and Qwen2.5VL-3B and to SmolVLM-2.2B on Jetson Orin (Table 2). Accuracy is preserved or improved in all cases (7B: +2.2%; 7B-4bit: +0.2%; 3B-4bit: +0.1%; SmolVLM: within 0.4% of baseline), indicating the gains are not tied to one backbone or scale.
For 236B-scale models, we would respectfully note they fall outside the paper's target setting. As stated in Secs. 1 and 3.1, UTOPI is designed for the 8–16 GB memory budget of current AR-class hardware. A 236B model requires more than 100 GB even under 4-bit quantization, which is an order of magnitude greater than the storage capacity of any wearable device. Nevertheless, we expect the gains to transfer to larger models. UTOPI performs compression before the visual tokens reach the language decoder, so the compressed output is independent of decoder scale. Model scale therefore cannot affect the compression itself; it could only modulate the gains through how the decoder responds to the same compressed input. Across the 2.2B to 7B backbones from three architecture families that we evaluated, the gains remain stable and no such scale-dependent difference is observed. We will add this discussion to the next revision of the paper.
Q2: How does the MLP generalizes across datasets? if trained on EgoEye, does it transfer well to EgoSchema without retraining?
A: Thank you for your comment and suggestions. Yes, and Table 1 already tests exactly this setting. The saliency MLP is calibrated only on EgoEye, as stated in Secs. 3.2 and 4.1, because calibration requires ground-truth eye-tracking gaze aligned with QA supervision, which among our benchmarks only EgoEye provides. EgoSchema releases no gaze modality, so fine-tuning on it is not possible.
Consequently, all EgoSchema and EgoGazeVQA results in Tables 1–3 are precisely the zero-shot transfer setting the reviewer asks about: the same EgoEye-calibrated MLP, applied without any retraining to benchmarks built by other groups from entirely different source videos, devices, wearers, and activities, still improves over the uncompressed baseline, reaching 64.8% versus 60.1% on EgoSchema at the 15% budget and 49.0% versus 47.8% on EgoGazeVQA. In addition, the MLP scores individual token embeddings and receives no task or dataset identity. We will state this transfer interpretation explicitly in Sec. 4.1, and add the domain-generalization discussion requested in the Limitations.
Response to Weakness 1 and Weakness 2
W1: EgoEye benchmark construction raises validity concerns: the saliency MLP is fine-tuned on 2K EgoEye samples, and they are all generated using VLM without manual review there may be distributional biases that favor fine-tuned model.
A: Thank you for your comment and suggestions. We would like to clarify that the generated QA pairs did undergo manual review: as stated in Checklist items 14 and 15, an internal quality-control pass over the generated data was performed. We acknowledge that the main text does not document this process, and we will fix this omission by adding the QC protocol to the appendix. Regarding the concern that calibrating the MLP on EgoEye biases evaluation in our favor: the external-benchmark results provide direct counter-evidence: the same MLP transfers zero-shot to EgoSchema and EgoGazeVQA and still improves over uncompressed baselines there (see Q.2).
W2: For EgoSchema and portions of Ego4D that lack gaze signals, the authors estimate gaze using SUM. The accuracy of SUM on Ego4D videos is unknown and could be substantially worse. This undermines the claim that UTOPI is specifically designed for AR-native signals.
A: Thank you for your comment and suggestions. The paper already contains two experiments that directly measure how much accuracy is lost when real gaze is replaced by estimates, and both show the loss is small.
(a) On EgoEye, where real Aria eye-tracking is available, we replaced the ground-truth gaze with SUM predictions and reran the evaluation: accuracy drops by only 1.2% as reported in Sec. 4.4. This directly measures how well SUM substitutes for real gaze on egocentric footage.
(b) Table 6 perturbs the gaze locations with 75–300 px of noise, and accuracy degrades by at most 2.9%. For reference, EgoEye frames are 1408×1408 pixels and the Aria RGB camera covers a field of view of about 110°, so one degree of visual angle spans roughly 12.8 pixels. The tested 75–300 px noise therefore corresponds to angular errors of roughly 6° to 23°. Consumer eye trackers typically err by only 0.5° to 2°, so our perturbations stress conditions an order of magnitude beyond real hardware, and far beyond any plausible saliency-prediction error.
We would also offer a reframing: since our EgoSchema results were obtained almost entirely (99.7% of source videos) under predicted gaze, they already demonstrate that UTOPI does not depend on eye-tracking hardware. On devices that do provide real gaze, which is the AR design target validated on EgoEye, performance is strictly better. We will explicitly discuss the real-vs-estimated gaze composition of our evaluation and this framing in the revision.
Response to Weakness 3 and Weakness 4
W3: IVOC only considers pairwise consecutive frames, which may miss the scenarios (which is very common in egocentric case) where user looks away and comes back to the same scene. Token redundancy may not be detected in such cases.
A: Thank you for your comment and suggestions. The pairwise design is a deliberate choice to keep per-frame latency and memory constant for on-device streaming. To detect revisits, the system would have to store tokens from all earlier frames and compare each incoming frame against that history. Both the storage and the comparison cost keep growing as the video gets longer, which a streaming system on AR hardware cannot afford. Pairwise comparison also targets the dominant redundancy mode we measured: as shown in Fig. 2c, 32% of consecutive frame pairs exhibit less than 9% pixel change.
Two factors soften the impact of missed revisits. First, AGTS operates on every frame independently, so a revisited scene is still spatially compressed even when IVOC misses the temporal correspondence. Second, the consequence is only a missed compression opportunity rather than an error: no token is ever wrongly deleted.
We also note that the geometric reprojection mapping f(·,·) in Sec. 3.3 is defined for any frame pair with known relative pose, so IVOC can extend naturally to a sliding window over the last k frames, trading extra compute for higher compression. We will add this discussion to the limitations and acknowledge the missed compression opportunities there, as suggested.
W4: Though the work is targeted for resource constrained AR devices and the baseline benchmarking is done on 7B model, at least the discussion of applying this approach on the bigger models to see if the gains are similar or not - would have made the method contribution even stronger. The overall quality i.e. 50-60% accuracy, may not be acceptable for real world deployment quality bar.
A: Thank you for your comment and suggestions. For the model-scale discussion, please see our response to Q.1, we will add it to the revision. On whether 50–60% accuracy is acceptable for real-world deployment: we agree that current accuracy alone does not yet meet that bar, but this ceiling is set by today's VLMs on long-video QA rather than by compression. As shown in Table 1, the uncompressed 7B baseline scores in the same range, reaching 60.1% on EgoSchema, where the reported human accuracy is about 76% [44]. UTOPI matches or exceeds this baseline using only 15% of the tokens. We would also note that the real-world deployment bar on AR hardware is not accuracy alone: memory and latency are equally binding constraints, and these are precisely the axes UTOPI addresses. As shown in Table 2, on-device memory and latency stay within AR budgets while accuracy is preserved. As summarized in our contributions in Sec. 1, UTOPI is a plug-and-play pre-compression module whose goal is to lower computation and memory costs while maintaining accuracy, enabling video understanding under tight AR resource constraints. This benefit applies to whichever VLM it is integrated with, and as stronger VLMs emerge, integrating them with UTOPI will bring their improved accuracy to AR hardware.
- Scope
- Moderate ethical concerns (can likely be resolved) (yellow)
Read ethics review
Ethics review
Concern 1 (moderate): Missing societal impact and privacy discussion.
- The system continuously processes egocentric video, gaze, and pose signals, and selectively retains tokens of user-attended regions, effectively creating a record of what the wearer looked at, with privacy implications for both wearer and bystanders.
- The authors' Broader Impacts response (N/A) is inadequate. However, the work uses only existing consent-based public datasets (AEA, Nymeria) with no new data collection, so the concern is not intrinsic to the work.
- Mitigation: add a Broader Impacts section to the camera-ready covering wearer/bystander privacy, dual-use risks of persistent egocentric memory, and possible safeguards.
Concern 2 (minor): Checklist inconsistency on EgoEye quality control.
- EgoEye QA pairs are VLM-generated, yet checklist Q14 claims internal manual review.
- Mitigation: authors should clarify the human-verification fraction and QC procedure in the rebuttal. This is primarily a transparency/validity matter for the technical reviewers.
On PvZF's "Major Concern" flag
The written review identifies no specific copyright, consent, or data-use violation beyond insufficient discussion; both datasets were collected with participant consent. Severity assessed as moderate, not serious.
Recommendation:
Concerns are addressable through revision and do not warrant rejection on ethical grounds; the decision should rest on technical merits.
1 comment
Response to the Ethics Review
Thank you for the careful ethics review and the balanced assessment. For Concern 1, we will add a Broader Impacts section to the camera-ready covering wearer and bystander privacy, the dual-use risks of persistent egocentric memory, and safeguards such as on-device processing and user control over recording and data storage. For Concern 2, the QC procedure and statistics are clarified in our response to Reviewer LX3K Q5: all released QA pairs were human-reviewed under a blind protocol, rule-based screening and LLM blind filtering accept about 50% of candidates, human review adopts about 70% of the rest, and blind human accuracy reaches 83.5%. These details will also be documented in the appendix.
- Scope
- Minor or negligible ethical concerns (green)
Read ethics review
Ethics review
Severity: Low Possible inappropriate use for ongoing surveillance (Minor) Enhancing the effectiveness of long-video comprehension could render ongoing AR recording and assessment more feasible. Although this feature isn't directly provided by the suggested approach, the efficiency improvements could inadvertently enable ongoing surveillance if used carelessly. Mitigation: The document must recognize this potential and clarify that the intended use is assistive AR, incorporating suitable protections like user control regarding recording and data storage.
Severity: Low Dataset representativity (Minor) The suggested EgoEye benchmark is built from current egocentric datasets and may not completely capture the variety of users, settings, or gaze patterns experienced in actual AR applications. Mitigation: The writers ought to recognize these constraints and mention that subsequent assessments involving a wider array of populations and implementation contexts would enhance trust in the method's applicability.
1 comment
Response to the Ethics Review
Thank you for the thoughtful ethics review. We will address both points in the camera-ready: the societal-impact statement will acknowledge the potential for surveillance misuse, clarify that the intended use is assistive AR, and describe safeguards such as user control over recording and data storage. We will also acknowledge that EgoEye may not fully capture the diversity of users, settings, and gaze patterns in real AR applications, and note that future evaluations on broader populations and deployment contexts would strengthen confidence in the method's applicability.
- Scope
- Moderate ethical concerns (can likely be resolved) (yellow)
Read ethics review
Ethics review
Verdict: Moderate-not blocking
The ethics side is mostly fine. The two things that need attention are both documentation issues the authors can handle in the camera-ready.
What’s already good.
- The work builds on existing public datasets, all collected with consent and de-identified, with no new data collection of their own. Marking IRB and crowdsourcing as N/A is the right call.
- I also wouldn’t treat the method as a surveillance or biometric risk in itself. It’s a compression module that uses only 2D gaze points.
Two gaps, both minor
- Broader impacts and safeguards are marked N/A with a one-line dismissal. For a system premised on a continuous first-person recording with eye-tracking N/A doesn’t hold. A short paragraph would settle it; genuine mitigations about on-device processing, ~95% fewer visual token retained, no re-identification.
- Licenses are marked yes but none are named. The source datasets carry restrictive data-use agreements, so the author should name each asset’s license.
1 comment
Response to the Ethics Review
Thank you for the careful ethics review and the clear guidance. We will address both points in the camera-ready: the N/A broader-impact entry will be replaced with a short statement covering on-device processing, the roughly 95% reduction in retained visual tokens, and the absence of re-identification risk, and we will name the license of each source dataset, AEA, Nymeria, and Ego4D, in the appendix.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Response to Metareview
We thank the Area Chair for the careful meta review. We have posted detailed responses in every reviewer thread, including several new experiments completed during the rebuttal. Below we summarize how each of the four issues is addressed.
1. Benchmark validity of EgoEye, and gaze estimation and availability on EgoSchema.
For EgoEye label quality, we report the full QC statistics in our response to Reviewer LX3K Q5: 100% of released QA pairs were human-reviewed under a blind protocol where reviewers answer without seeing the generated answer; rule-based screening and LLM blind filtering accept about 50% of candidates, and human review adopts about 70% of the rest; blind human accuracy reaches 83.5%, versus about 60% for the strongest models. The MLP calibration split is disjoint at the video level, 18 training versus 28 evaluation videos, so no evaluation video is ever seen during training. For gaze availability, replacing real gaze with SUM predictions costs only 1.2% on EgoEye, and Table 6 shows at most 2.9% degradation under gaze noise of 75 to 300 px, corresponding to roughly 6 to 23 degrees, an order of magnitude beyond real tracker error of 0.5 to 2 degrees. Notably, 99.7% of EgoSchema source videos rely on predicted gaze, yet UTOPI still improves over the uncompressed baseline there by 4.7%, so the method does not depend on eye-tracking hardware.
2. Novelty of individual components.
We would assess the contribution at the system level, as Reviewer PvZF's own strengths note. The pairing of free AR-native signals with egocentric token redundancy is new, and the way IVOC establishes token correspondence, first reprojecting tokens across frames geometrically and then verifying each match by feature similarity, is new to the token compression literature. Component simplicity is a deployment constraint rather than a capability ceiling: the whole module must run within 673 ms on device, as reported in Table 2.
3. Generalization to longer videos.
UTOPI is streaming by construction: AGTS operates per frame and IVOC touches only consecutive frames, so the per-frame cost stays constant regardless of video length. Because the pipeline samples a fixed number of frames, the retained token count does not grow with duration; longer videos are covered at a sparser rate. Table 3 further shows headroom for denser coverage: accuracy is maintained while removing up to 95% of tokens on Qwen2.5VL and 85% on PLLaVA.
4. Statistical consistency of the gains.
We ran the requested seed study during the rebuttal, reported in our response to Reviewer LX3K Q1. The only stochastic component is the saliency MLP calibration; we retrained it with 3 additional independent seeds, giving 4 runs in total. At the 15% budget, UTOPI reaches 60.1% ± 0.77% on EgoEye, 64.8% ± 0.22% on EgoSchema, and 49.1% ± 0.26% on EgoGazeVQA. The margins over the strongest baseline exceed the seed noise band on all three benchmarks, and every individual run on every benchmark stays above the uncompressed baseline while using 15% of the tokens.
Beyond these four points, the rebuttal also adds a uniform frame sampling baseline, which falls below even the uncompressed baseline on all three benchmarks, an IMU pose noise study showing smooth degradation, and an STE versus Gumbel-softmax comparison. We hope these responses and new results address the concerns, and we are happy to provide any further clarification.