MC^2: Monte Carlo Correction for Fast Elliptic PDE Solving
Ethan Hsu, Ivan Ge, Hong Meng Yam
NeurIPS 2026
TL;DR. Extremely Fast Elliptic PDE Solver
Abstract. Partial differential equation (PDE) solvers underpin modern computer graphics, geometry processing, and scientific computing. Classical Monte Carlo PDE solvers such as Walk-on-Spheres (WoS) provide mesh-free estimations that are unbiased, but with accuracy limited by sampling and numerical approximation. Learned solvers are fast but biased and brittle under distribution shift. We therefore present MC$^2$, a hybrid Neural Network-Monte Carlo PDE solver that treats a low-budget Monte Carlo solution as a structured estimator of the true field and learns a single-pass neural correction to recover a high-fidelity solution. MC$^2$ matches the accuracy of solutions using over more Monte Carlo samples, outperforming all evaluated mesh-free classical, denoising, and neural-operator baselines. To enable reproducible study of finite-compute PDE solving, we additionally release PDEZoo, the largest standardized elliptic PDE benchmark to date: 2 million PDEs spanning 5 elliptic families and unlimited geometric compositions, with analytic ground truth and multi-budget Monte Carlo trajectories. Together, MC$^2$ and PDEZoo (1) empirically establish that finite-sample Monte Carlo error is structured, learnable, and correctable in a single forward pass, (2) show that we can solve PDEs $\sim$218$\times$ faster than WoS at matched accuracy and achieve a $\sim$171$\times$ reduction in inference time relative to state-of-the-art diffusion methods while attaining higher accuracy, and (3) provide the reproducible evaluation infrastructure the field has so far lacked.
Code & Data: https://mc-error-correction.github.io
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 4 reviews · OpenReview
Updated 25 Nov 2026, 03:46 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The paper introduces a method to solve elliptic PDEs by combining a Monte Carlo solver with neural correction.
Reviewers praised the compelling motivation, simple and effective approach, generalization to unseen PDE families, and the usefulness of the PDEZoo benchmark. The major weaknesses raised were 1) comparisons to baselines might not be fair due to the method receiving more information in its inputs, 2) lack of detailed reports of timing/memory and ablations, 3) missing modern baselines, 4) several technical concerns raised by Mpjh.
Initial recommendations were mixed. All reviewers acknowledged the thorough rebuttal and either raised or maintained their scores, resulting in a consensus. Thus, I recommend acceptance.
To the authors: please fix the author list for references [14] and [32] as they were flagged as problematic by the auto-checker.
Final justification
All reviewers acknowledged the thorough rebuttal and either raised or maintained their scores, resulting in a consensus. Thus, I recommend acceptance.
Read meta-review
Meta-review
The paper introduces a method to solve elliptic PDEs by combining a Monte Carlo solver with neural correction.
Reviewers praised the compelling motivation, simple and effective approach, generalization to unseen PDE families, and the usefulness of the PDEZoo benchmark. The major weaknesses raised were 1) comparisons to baselines might not be fair due to the method receiving more information in its inputs, 2) lack of detailed reports of timing/memory and ablations, 3) missing modern baselines, 4) several technical concerns raised by Mpjh.
Initial recommendations were mixed. All reviewers acknowledged the thorough rebuttal and either raised or maintained their scores, resulting in a consensus. Thus, I recommend acceptance.
To the authors: please fix the author list for references [14] and [32] as they were flagged as problematic by the auto-checker.
Final justification
All reviewers acknowledged the thorough rebuttal and either raised or maintained their scores, resulting in a consensus. Thus, I recommend acceptance.
2 comments
AC Response Part 2
4. Technical concerns raised by Reviewer Mpjh. We agree that several technical details and qualifications were not stated clearly enough in the original submission. For the biharmonic problem, we impose the Navier boundary conditions and on where both and are obtained from the manufactured solution. Writing , the problem decomposes into
and
For the Helmholtz problems, we use the exact two-dimensional ball Green's-function () representation with boundary weight to compute Monte Carlo solutions, explicitly excluding Dirichlet resonances and capping the radius below the first zero of at .
The measured errors follow the expected Monte Carlo convergence rate of over the relevant budget range and no evaluated walk reaches the truncation cap of WoS steps, and the results are stable under changes to the -shell.
We also agree that the original theoretical language was too broad. Conditional-mean optimality is a population statement rather than a guarantee for our trained network, and MC² is not necessarily globally contractive or exactly unbiased. We therefore ground our statistical claims in the measured empirical behavior. Across the full test set, MC² substantially reduces variance while introducing only a small bias, yielding a large reduction in total MSE at the operating budget. Furthermore, the corrected estimator remains more accurate than raw WoS across every tested budget, improving all instances through the moderate-budget regime and most instances even at the highest budgets. At high budgets, MC²'s error approaches a stable plateau that agrees with the solution input bias floor, while raw WoS continues to converge. The revision will report these measured finite-budget gains, noise-direction contraction, high-budget plateau, and estimated crossover explicitly.
To test whether MC² primarily fits the manufactured-solution prior, we evaluated repeated independent WoS realizations and a new 500-instance test set using atom families absent from training. Like the main evaluation set, this test set also contains 40% biharmonic and Helmholtz problems which were never trained on. Together, this indicates that MC² generalizes strongly to PDE domains and problems highly dissimilar from the training set. In particular, on this unseen atoms test set, MC² retains a median PSNR of 42.32 dB, whereas the prior-driven FNO operator falls below the raw WoS input.
Finally, we acknowledge the inconsistent values in the submitted paper. We reconstructed the evaluation using one checkpoint, a fixed 5,000-instance test manifest, one metric implementation, and one hardware configuration. Tables 2–3 are definitive and are fully reproduced. Every conflicting value has been traced to an older checkpoint or a mislabeled baseline (see detailed response). All revised tables and figures have been regenerated, and we will release the checkpoint identifier, manifest, evaluation code, protocol, and per-instance predictions such that it is fully reproducible.
Conclusion
We believe these additional experiments and clarifications directly address the four concerns identified in the meta-review while preserving the central result: conditioning on a low-budget WoS realization enables a large and robust improvement in finite-compute PDE solution quality.
- Rating
- 5/6
- Confidence
- 2/5
- Quality
- 3/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes , a novel method for efficiently solving elliptic PDEs, alongside PDEZoo, a new benchmark designed to evaluate its performance.
The framework consists of a Monte Carlo PDE solver and a neural estimator that corrects its output. Generally, achieving high accuracy with a Monte Carlo PDE solver requires a large number of samples, making the process computationally expensive. To address this, the proposed method first executes the Monte Carlo PDE solver with a limited sample size. Although this fewer-sample approach introduces errors due to sample insufficiency, the final high-accuracy result is obtained by feeding this initial output into a modified Swin-UNet architecture that effectively corrects the errors.
Furthermore, the paper introduces PDEZoo, a synthetic dataset consisting of 2M pairs of elliptic PDEs and their analytical solutions, to validate the effectiveness of the proposed method. The experimental results demonstrate that the proposed method solves PDEs faster and more accurately than the baseline methods.
Strengths and weaknesses
Quality
- The core motivation of integrating classical numerical methods with neural architectures to enhance precision and computational efficiency is well-justified, with its efficacy thoroughly validated by experimental evidence. The authors have conducted a rigorous evaluation regarding both accuracy and runtime, showcasing that the proposed approach successfully surpasses existing baseline methods.
Clarity
- The paper is well-written, allowing readers to easily understand both the proposed method and the introduced benchmark.
- In the experiments, multiple baseline methods are appropriately selected, and the rationale behind their selection is clear. Furthermore, the experimental protocol is well-defined, ensuring sufficient reproducibility.
Significance
- As demonstrated in Table 3, the proposed model outperforms other baseline methods even on PDE families that were not included in the training set, indicating that the model generalizes remarkably well.
- The PDEZoo benchmark proposed in this paper is one of the largest scales for handling elliptic PDEs and is expected to serve as a cornerstone for future research in this field.
Originality
- The proposed strategy of integrating a neural estimator to rectify the results of a Monte Carlo PDE solver represents a unique contribution not seen in existing literature. It is particularly remarkable that this framework bypasses the computational bottleneck of traditional methods by avoiding the generation of dense sample points, leading to a substantial speedup in performance.
Other minor weaknesses
- The citation for the FNO datasets is broken in line 93.
Questions
- Is the only input to the neural estimator? Is the model agnostic to other factors related to the target PDE problem, such as information about the geometry?
- Would it be difficult to conduct additional evaluations using datasets other than PDEZoo?
Limitations
yes
Final justification
I maintain my original score. My concerns regarding the model's inputs have been addressed by the authors' rebuttal.
Formatting concerns
no
2 comments
Rebuttal
We thank you for your positive review!
Q1. Inputs and geometry.
Thank you for asking us to clarify the corrector's inputs. The corrector's inputs are the low-budget WoS field and the source term on the same grid, nothing else. It receives no boundary values, coefficients, meshes, or solver internals (the domain mask is used only in the training loss). Geometry enters implicitly through itself, whose support and structure are shaped by , and the model is geometry-agnostic in the operative sense. One set of weights serves all eight primitive domains and their Boolean compositions with no per-geometry training. A new bit-identical-capacity ablation makes these roles precise. Given explicit geometry and the full PDE specification but no observation, the network reaches only 8.56 dB, below the raw input (13.91), while alone reaches 40.56 and reaches 44.29. We will state this input specification explicitly in Sec.~3 of the camera-ready.
Q2. Evaluation beyond PDEZoo.
We agree that evaluation beyond PDEZoo would further strengthen the paper. No existing public benchmark supports the finite-compute setting end to end, since this requires per-instance Monte Carlo trajectories at multiple budgets and discretization-free ground truth (Table 1), which is why PDEZoo exists. We therefore performed three additional checks. First, we ran a head-to-head comparison against Neural Walk-on-Spheres using the official code on a pre-registered 30-case subset of its supported class, where MC2 reaches lower error at less wall-clock. Second, we evaluated on a 500-case pack whose manufactured solutions use only atom types absent from the training dictionary, where MC2 reaches 42.32 dB median against 45.54 in-distribution while the FNO operator baseline collapses to below the raw input. Third, we applied the corrector without retraining at on 510 instances, where every instance improves over its own raw field. We will also add an evaluation on independently solved FEM/FDM reference problems to the camera-ready.
Minor.
Thank you for pointing this out. We will fix the duplicated bibliography keys for the FNO datasets in the camera-ready (they have now been deduplicated).
The authors have adequately addressed my concerns. I will maintain the current score.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 4/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposes MC², a hybrid PDE solver that treats a low‑budget Walk‑on‑Spheres (WoS) Monte Carlo solution as a structured, stochastic estimator and learns a single-pass neural corrector (a SUNet variant) to reduce variance and recover high-fidelity solutions. The authors also introduce PDEZoo, a large-scale benchmark of 2M analytic elliptic PDE instances with multi-budget WoS trajectories designed for finite-compute evaluation. Empirically, MC² improves PSNR by over 30 dB on B=8 inputs, matches the accuracy of WoS with roughly 512–2,048× more samples, generalizes to held-out PDE families, and outperforms classical denoisers, neural operators, and diffusion baselines on 2D problems.
Strengths and weaknesses
S1. The core idea—treating low-budget WoS outputs as structured estimators and learning a single-pass, distribution-wide corrector—is simple yet powerful, and distinct from per-instance control variates or iterative generative sampling.
S2. Framing variance reduction as estimator correction post-processing (rather than altering the sampler) cleanly preserves the generality and robustness of WoS while improving the bias–variance tradeoff.
S3. The work unifies concepts from variance reduction and learned denoising into a practical solver usable at any WoS budget, not tied to a particular PDE family at test time.
W1. The method introduces bias (as acknowledged), but the bias–variance analysis sits in an appendix rather than the main text, and the condition under which correction is guaranteed to reduce MSE is not stated where a reader would look for it. This is a main-text presentation gap in supporting analysis, not a core deficiency.
W2. There is an inconsistency between claims that the corrector needs no PDE inputs at inference and experimental sections stating that the source term f is provided to MC² at inference; this affects the method’s stated generality.
W3. The operator-learning baselines are information-starved in a way that drives the central comparison: FNO/PINO receive only f, not the boundary conditions g or geometry Ω that are needed to define the solution, which likely accounts for their weak numbers. Since the paper's case rests on outperforming these baselines, the setup has to be evened out before the margin can be read as a real advantage (I think this is important).
W4. Comparisons omit recent WoS variance-reduction techniques that preserve unbiasedness while reducing variance, such as boundary value caching (BVC), neural control variates with automatic integration (NCV-AI), and neural walk-on-spheres/operator hybrids (NWoS, WoS-NO). Without these, it is difficult to gauge MC²’s advantage over modern, task-specific MC improvements.
W5. Metrics are predominantly image-style (MSE/PSNR/LPIPS). PDE-relevant diagnostics such as relative L2, H1 seminorms, PDE residuals, and boundary-condition satisfaction are not reported; these would better characterize solver quality.
W6. Claims of ~1000× speedup rely on a compute–accuracy plot without detailed hardware parity, precise time breakdown (WoS vs NN forward), or full runtime tables; reproducibility of timing claims could be strengthened.
Questions
Q1. What exactly are the inputs to MC² at inference? Section 3 states the corrector does not need PDE coefficients or boundary conditions, but Section 5.1 says the source term f is provided at inference. Please clarify and quantify the impact of including/excluding f across all families and budgets.
Q2. How were FNO/PINO configured—do they receive Ω and boundary conditions g (and any coefficients) in addition to f? If not, why not, and how do you justify fairness given these are necessary to define the solution?
Q3. Can you compare MC² against at least one strong, modern unbiased variance-reduction technique (e.g., BVC, NCV-AI, NWoS) under equal-time settings? If wall-clock constraints prevent full-scale runs, can you provide smaller-scale or targeted comparisons?
Q4. Please report PDE-centric metrics (relative L2, H1 seminorms, PDE residuals, boundary-condition error) to ensure that the corrected fields remain physically consistent and not merely visually plausible.
Q5. How sensitive is MC² to domain resolution and discretization? Does performance hold when inference is performed at a different grid resolution than training, or on unstructured discretizations?
Q6. For Helmholtz and Biharmonic test cases: how are the WoS trajectories generated? Are these standard WoS variants, boundary integral samplers, or another estimator? Some detail is necessary to assess the robustness and transfer claims.
Q7. Can you provide explicit hardware, batching, and timing breakdowns for WoS sampling, NN forward pass, and any I/O to support the “~1000× faster” claim and the Pareto frontier in Figure 4c?
Q8. Have you evaluated on variable-coefficient problems (non-constant α, ω, σ) or 3D geometries? If not, what obstacles do you foresee, and what modifications would be required?
Limitations
yes
Final justification
I raised my score from 3 to 4 after a substantive author response that ran essentially every experiment I requested rather than answering by assertion. The authors retrained FNO/PINO with full inputs (g, Ω), and, more convincingly, isolated formulation from architecture within the same FNO family: the operator-to-correction formulation swap alone moves median PSNR from ~15 to ~32 dB, larger than the residual architecture gap. In addition, relative L2, H1, residual, and boundary error were added. The finding that PINO attains the lowest residual yet the worst solution error, because residual is blind to the boundary-determined component, is a genuinely informative result that also validates the request.
Formatting concerns
None
4 comments
Rebuttal
We thank you for your constructive comments. We ran every requested experiment below, and unless labeled otherwise, numbers come from a single re-evaluation on the full test set of 5,000 test instances with a single forward pass on one A100 node.
W1. Bias-variance in the main text
We agree that the bias-variance analysis and the condition for MSE reduction should appear in the main text. We will move this analysis to Sec. 3 and state the condition explicitly:
Our measurements show that this condition holds by a wide margin. At , raw WoS has negligible measured bias, with median , and a mean variance of . The corrector removes of this variance while introducing median , reducing total MSE from to .
This benefit persists across all tested budgets and PDE families. Even at , which is the operating budget, corrected median MSE remains lower than raw WoS, and the estimated crossover occurs only near walks/px.
We will also replace the unverified Lipschitz assumption with direct measurements. The network is not globally contractive, but along perturbations induced by actual WoS noise, it has median gain , with all measured gains below , consistent with the observed variance reduction.
W2/Q1. Inputs at inference
Thank you for identifying this inconsistency. The corrector consumes and nothing else. Sec. 3 will be corrected to use this single definition throughout.
We also quantified the impact of at bit-identical capacity using one 4-channel network, with forbidden channels zeroed, and one 40-epoch schedule for all configurations. The configuration reaches dB versus dB for alone, so is worth dB at . Per-family and per-budget breakdowns will be added to the camera-ready from the same runs.
W3/Q2. Operator baselines were information-starved
You are correct that the released operator baselines were information-starved. The released FNO and PINO consume only, and the internal coordinate grid is identical for every sample and carries no instance geometry.
We have now also retrained both models from scratch with input channels. FNO rises from to dB mean, an improvement of dB, while PINO reaches dB with its physics loss unchanged at , as published. The loss therefore remains harmful in this regime even with complete inputs. Its relative error diverges on hard instances, with a median of over the full test-set evaluation. Both configurations will appear side by side in the camera-ready.
The retrained numbers also sharpen the finding. Even complete PDE information without the Monte Carlo observation is insufficient. The same-capacity configuration given but no scores dB, below the raw input at dB, while the -only configuration reaches dB. This demonstrates our distinct contribution.
To separate formulation from architecture, we also trained a capacity- and information-matched FNO corrector, with parameters, or the parameter count of , and inputs . We scored it on the same test set.
| Same FNO family, same training-data mode | Parameters | Median PSNR |
|---|---|---|
| Operator formulation | 16.8M | 15.05 |
| FNO correction formulation * | 99.8M | 32.00 |
| correction formulation, Swin backbone | 99.7M | 45.54 |
Holding the architecture family fixed, the formulation swap alone is worth dB, larger than the dB architecture premium that remains. We believe this addresses the fairness concern quantitatively rather than by assertion, since it shows that the operator baselines' weakness is not merely an artifact of starved inputs, but also of the operator formulation itself in this regime.
We note that the FNO pipeline trains on Laplace, Poisson, and Yukawa, following the released-baseline convention shared with the operator run, so the comparison is internally consistent. On those three families, it scores a median of dB, compared with at to dB.
W4/Q3. Modern WoS variance reduction
Thank you for suggesting this comparison. We ran NWoS on its supported problem class as an additional baseline.
We used the official NWoS code through a validated adapter, with the sign convention verified to on a manufactured case. We used a pre-registered mechanical subset consisting of Poisson problems on primitive domains, NWoS's supported class, with 30 seeded cases selected from 725 eligible cases. We used a per-instance training budget of 300 seconds, selected as the best option in a 60/120/300-second pilot.
NWoS reaches a median relative error of , with a mean of , at a median runtime of 376 seconds per instance. On the identical cases, reaches at 1.56 seconds end to end. This corresponds to approximately lower error at approximately less wall-clock time.
We will state the accounting asymmetry explicitly: NWoS trains separately for each problem, whereas trains once across the distribution and performs zero-shot inference for each instance. additionally covers the four families outside NWoS's scope.
We will discuss BVC, NCV-AI, and WoS-NO in Related Work, with a structured comparison covering preservation of unbiasedness, per-instance versus amortized training, and iterative versus single-pass inference in the camera-ready version.
W6/Q7. Timing and the speed claim
Thank you for requesting a complete timing breakdown. We timed every stage on one idle A100 at batch size 1. The requested breakdown is below, and Fig. 4c will be regenerated from these measurements.
| Stage or reference point | Wall-clock |
|---|---|
| WoS solve, , standalone | 0.891 s |
| Corrector forward pass, single pass, fp32 | 0.030 s |
| End-to-end at | 0.92 s |
| Harness I/O, one-time and outside the solve path | 0.28 s |
| WoS at | 2.41 s |
| WoS at , first parity with quality | 200.5 s |
| WoS at | 801.2 s |
We used medians over 50 stratified test instances on a single idle A100-80GB with PyTorch 2.1. Both stages used batch size 1, a warm start, and solver settings identical to those in the paper.
The wall-clock ratio at parity is
We will therefore state the claim as two separate measured figures:
- fewer Monte Carlo iterations
- lower wall-clock time on identical hardware
The model has 99.68M parameters, requires 64.03 GFLOP per forward pass, and uses 685 MiB of peak memory. The camera-ready compute appendix will report the complete per-budget ladder and precision variants, together with a reproduction guide in the public codebase.
Q5. Resolution and discretization
Because WoS is mesh-free and pointwise, the estimator can evaluate at any resolution or scattered query set. The corrector applies in a sliding-window fashion. At , it runs as a single tile.
We tested this directly on 510 instances rendered at with WoS at , applying the corrector trained at resolution 256 through Hann-blended tiling, with tile size 256 and overlap 32, without retraining.
Raw WoS error is statistically identical across resolutions, with median relative error of at and at . This confirms that the Monte Carlo noise is per-point rather than per-grid.
The corrector transfers with no net quality loss, improving every one of the 510 instances relative to its own raw field. The paired median relative error improves from to .
Because the walk computations are GPU-parallel and setup-dominated, processing as many pixels requires roughly the same wall-clock time: 0.83 seconds for WoS, plus 0.29 seconds for 25 tiles.
We will add the point-query setting to Sec. 4.4 in the camera-ready.
** Response continued in reply **
Rebuttal Part 2
W5/Q4. PDE-centric metrics
We agree that PDE-centric metrics are important. We measured them on the test set, with medians reported below.
The residual is the discrete PDE residual relative to the same stencil applied to the stored analytic solution. The boundary metric is the median on a shell of at most 2 px. The ground-truth grid itself has a boundary metric of due to interpolation.
| Method | Relative | Relative | Residual / GT | Boundary |
|---|---|---|---|---|
| Ground truth, anchor | 0 | 0 | 1.0 | 0.017 |
| Raw WoS, | 0.827 | 24.1 | 0.021 | |
| NLM, best classical | 0.172 | 2.74 | 0.180 | |
| FNO operator | 0.508 | 1.58 | 0.639 | |
| PINO operator | 12.8 | 1.08 | 497 | 17.96 |
| U-Net, matched | 0.033 | 0.603 | 0.043 | |
| configuration, no observation | 1.06 | 1.23 | 1.24 | |
| 0.015 | 0.060 | 0.026 |
The ground-truth row is the anchor for the residual column, which is why that column is a ratio. A value of represents the analytic solution's own discretization floor under the same stencil at , rather than zero.
Values in this table are medians over the 300-case subset, so they differ slightly from the full test-set numbers quoted elsewhere. For example, PINO's relative error is here, compared with when pooled over the full test set.
Three findings are worth highlighting.
-
restores physics. It reduces the raw field's residual by approximately and its error by approximately , while preserving the boundary accuracy provided by WoS termination. In contrast, every classical denoiser damages boundary accuracy. NLM comes within one order of magnitude of in relative error, yet has its error, its residual, and its boundary error. This pattern holds within every family. For example, Helmholtz error falls from to .
-
Residual alone can be misleading and must be interpreted jointly with solution error. PINO differs from FNO only through its physics loss, with the same architecture, inputs, data, and schedule, so this comparison directly isolates the effect of that loss. Adding the physics loss lowers the residual by to :
- Laplace:
- Poisson:
- Helmholtz:
At the same time, it raises relative error by to on the same three families:
- Laplace:
- Poisson:
- Helmholtz:
This occurs because the residual constrains a field only up to a solution of the homogeneous equation, so it cannot detect the component determined by the boundary data. PINO therefore reports the lowest residual in the table while its boundary error is approximately the ground-truth floor and its solution error is the worst of any method shown. is the only method near the floor on all four axes simultaneously.
-
A residual gap remains. The residual of remains approximately the ground truth's own discretization floor. We will state this explicitly in Limitations.
Rebuttal Part 3
Q6. Held-out trajectory generation
Thank you for requesting clarification. Both solvers use ball-based WoS constructions rather than boundary-integral samplers.
Biharmonic. We impose the Navier conditions
with both functions determined by the manufactured solution. Writing , the problem decomposes into
followed by
The estimator is therefore a nested WoS construction in which the outer Poisson walk for uses independent inner WoS estimates of at its interior source samples .
Helmholtz. For
we use the standard two-dimensional WoS ball representation with the Green's function and boundary weight . We cap each radius at , so that and the step weight remains finite. We also exclude Dirichlet resonances.
Across all 1,000 instances, the smallest first eigenvalue is , and the minimum per-instance ratio is
We will add the complete probabilistic representations and pseudocode to the revised appendix.
Empirically:
- No biharmonic walk reaches the 256-step cap.
- Results are unchanged with a cap of 128.
- Varying from to changes the error by less than .
- Median MSE follows the expected rate.
- The log-log slopes are for Helmholtz and for biharmonic over the relevant budget range.
Biharmonic performance flattens only at very large , where discretization and -shell errors dominate Monte Carlo variance.
Q8. Variable coefficients and 3D
We have not yet evaluated variable-coefficient or 3D problems in this paper, but we agree that both are important directions for future work.
Variable coefficients require WoS variants for spatially varying coefficients, such as delta-tracking-style walks. The correction framework itself remains unchanged, with coefficient fields added as input channels. Likewise, extension to 3D is natural for WoS. The primary obstacles are developing a 3D or patched field-to-field backbone with manageable memory requirements and controlling the data-generation cost. We will state both as immediate next steps.
Conclusion Once again, thanks for your helpful comments! With the inputs clarified, the operator baselines re-run with complete inputs, the NWoS comparison, the PDE-centric metrics, and the timing measurements above, we believe the concerns you raised are now addressed with direct measurements. We welcome any further questions during the discussion period.
I thank the authors for their thorough answer. The new discussions properly address most of my concerns. I will raise my score.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 2/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes , a learned post-correction framework for fast elliptic PDE solving. Rather than replacing the Monte Carlo solver, the method treats a low-budget Walk-on-Spheres estimate as a noisy but structured estimator of the true solution, and trains a neural correction network to map this finite-sample estimate to a high-fidelity solution in a single forward pass. The experiments suggest that finite-sample Monte Carlo errors can be effectively corrected by a learned model, leading to substantial accuracy improvements over low-budget Monte Carlo estimates and several evaluated baselines.
Strengths and weaknesses
Strengths
-
The paper addresses the meaningful and practically relevant problem of improving the accuracy of elliptic PDE solutions under limited Monte Carlo sampling budgets.
-
The proposed correction framework is conceptually appealing, as it treats low-budget WoS estimates as structured inputs rather than simply replacing the numerical solver with a learned surrogate.
-
The proposed PDEZoo benchmark could be useful for evaluating finite-compute PDE solvers, since it provides analytic ground truth, multi-budget Monte Carlo trajectories, and diverse elliptic PDE instances.
Weaknesses
-
The practical computational advantage of is difficult to assess because the paper does not clearly report the correction network’s parameter count, forward-pass cost, memory usage, or end-to-end inference overhead beyond equivalent Monte Carlo sampling budgets.
-
The baseline comparisons would be stronger with information-matched correction baselines, since uses low-budget WoS estimates and source terms as inputs, while the evaluated neural operator baselines do not fully isolate whether the gains come from the correction formulation, the architecture, or the additional input information.
-
Although is motivated as Monte Carlo error correction, the neural correction step introduces distribution-dependent bias and may exploit priors from the procedural PDEZoo generator rather than correcting a universal Monte Carlo error structure, raising questions about whether the corrected estimator retains the theoretical advantages of Monte Carlo methods, such as unbiasedness and consistency.
Questions
-
Since the correction network is trained with supervised ground truth on low-budget WoS estimates from the training distribution, how does it behave when the test-time WoS input exhibits shifted or atypical error patterns? Could the authors provide robustness experiments for budget mismatch, unusually high-variance samples, or difficult geometries where the low-budget estimator is substantially worse than typical training examples?
-
Can the authors include stronger information-matched baselines, such as U-Net, FNO, or Swin-based models that take the same low-budget WoS estimate, source term, boundary/domain mask, and other available conditioning information as input?
Limitations
No. The authors discuss some aspects of the method and benchmark, but the limitations are not fully addressed.
Final justification
I thank the authors for the clarifications. After careful consideration, I prefer to keep my original score.
Formatting concerns
No major formatting or anonymity concerns noticed.
2 comments
Rebuttal
We thank you for your detailed comments, and ran new experiments and provided more information to address them below.
W1. Compute and overhead.
Thank you for raising this point. We measured the compute and overhead directly. The model has 99,681,129 parameters (380 MiB fp32), requires 64.03 GFLOP per forward pass, and uses 685 MiB peak inference memory at batch 1. The corrector forward pass takes 30.0 ms, a standalone WoS solve at takes 0.891 s, and the end-to-end runtime is 0.92 s per instance, so the network accounts for of runtime. WoS alone first matches MC² quality at , costing 200.5 s on the same GPU, giving fewer Monte Carlo iterations and wall-clock speedup. We will report the iteration count and wall-clock speedup in the camera-ready. Additionally, the published WoS cost (1.845 s) was a walk_batch=256 accounting artifact, and the true standalone cost of 0.891 s makes the corrected ratio larger than a naive recomputation would give. We will add a compute appendix with the full per-stage timing table (WoS / NN / I/O) on identical hardware.
W2/Q2. Information-matched baselines.
Thank you for suggesting these comparisons. We conducted these experiments over the weekend. A U-Net with 99,559,507 parameters (around the same as MC²), with identical inputs, data, and training schedule reaches 38.44 dB median vs. 45.54 for MC² (raw input 13.91). A bit-identical-capacity four-arm ablation (one 4-channel SUNet, forbidden channels zeroed) gives 44.29 for , 40.56 for alone, and 9.29 / 8.56 for the observation-free ablations and , both below the raw input itself. We also retrained the operator baselines with the full specification . FNO rises from 7.5 to 18.04 dB mean and PINO reaches 7.95, still far below any method that sees the observation.
The FNO variant you requested is now trained and scored. At 99,799,229 parameters (around the same as MC²) with the same inputs, it reaches 32.00 dB median (relative 0.093) on the same 5000 instances. Because this comparison holds the architecture family fixed and varies only the formulation, it isolates the contribution directly, showing that our architecture shows a very noticeable improvement.
| Same FNO family, same training data mode | params | PSNR med |
|---|---|---|
| operator formulation | 16.8M | 15.05 |
| correction formulation | 99.8M | 32.00 |
| MC² (correction formulation, Swin backbone) | 99.7M | 45.54 |
The formulation swap inside one architecture family is worth dB, larger than the dB architecture premium that remains, so the gain is attributable first to the correction formulation and second to the backbone, not to information or capacity. We note that the FNO pipeline trains on Laplace, Poisson and Yukawa (the released-baseline convention, shared with the operator run); on those three families it scores 35.3 median against MC² at 40–46.
W3. Does the corrected estimator retain unbiasedness and consistency?
We agree that the neural corrector is distribution-dependent and does not preserve the exact unbiasedness or asymptotic consistency of raw Monte Carlo. We therefore do not claim that it learns a universal Monte Carlo error correction, rather it is a learned post-processor whose benefit must be evaluated empirically on both in-distribution and held-out PDE families.
As quantified in our response to Review Mpjh, raw WoS has negligible measured bias, with median bias$^2=7.5\times10^{-7}$ compared with a mean variance of . The corrector removes of this variance while introducing median bias$^2=5.8\times10^{-5}$, reducing total MSE from to , a improvement. Feeding exact solutions through the corrector gives a median relative error of , directly measuring its bias floor.
This tradeoff remains favorable across all tested budgets. Even at , corrected median MSE is still lower than raw WoS. The corrected error eventually plateaus at MSE , consistent with the clean-input bias floor, while extrapolating the raw rate places the crossover near walks/grid point.
The underlying WoS estimator remains unchanged and unbiased, with only the neural post-processing step introducing bias. We will state this limitation explicitly in the camera-ready version and will not attribute the theoretical guarantees of raw Monte Carlo to the corrected estimator.
Q1. Robustness to shifted or atypical inputs.
Thank you for suggesting these robustness evaluations. We measured performance across four separate axes of shift.
Budget mismatch. The corrector is trained on yet improves the median instance at every stored budget up to , which is beyond its training range.
| Budget | raw MSE med | MC² MSE med | fraction improved |
|---|---|---|---|
| 2 | 3.59 | 100% | |
| 8 (operating point) | 0.906 | 100% | |
| 32 (end of training range) | 0.225 | 100% | |
| 256 | 0.0283 | 100% | |
| 2,048 | 99.8% | ||
| 32,768 | 92.9% | ||
| 131,072 | 76.7% |
Entries are medians over the same test instances, computed on interior (domain-masked) pixels in the raw solution frame with no normalization, so they are not convertible to the -frame PSNR above. Fraction improved is paired per instance, the share of instances whose corrected MSE is below their own raw MSE at that budget. The corrected error visibly plateaus at from onward, consistent with the clean-input bias floor discussed under W3.
Unusually high-variance samples and difficult geometries. The paired per-instance test at shows that every one of the 5000 instances improves, with bootstrap confidence intervals below zero in each of the five families. We provide the requested breakdown below rather than deferring it, grouped by geometry and by difficulty (forcing scale), with median PSNR reported.
| Geometry | raw | MC² | impr. | Difficulty | raw | MC² | fraction improved by MC² |
|---|---|---|---|---|---|---|---|
| composed | 16.03 | 47.19 | 100% | Q1 (easiest) | 24.51 | 59.24 | 100% |
| annulus | 18.60 | 48.21 | 100% | Q2 | 16.69 | 50.06 | 100% |
| stadium | 17.27 | 48.36 | 100% | Q3 | 9.57 | 39.88 | 100% |
| triangle | 17.40 | 48.70 | 100% | top decile | 7.35 | 32.62 | 100% |
| hexagon | 12.04 | 45.05 | 100% | ||||
| ellipse | 10.79 | 44.31 | 100% | ||||
| rectangle | 10.11 | 41.34 | 100% | ||||
| disk | 9.05 | 40.04 | 100% | ||||
| square | 10.59 | 38.55 | 100% |
Two findings are worth highlighting. Boolean-composed geometries, which we would expect to be among the hardest, are not (47.19 median, above the pooled 45.54), suggesting that the corrector is not relying on simple domain shapes. In addition, in the hardest decile of the benchmark, where the raw estimator reaches only 7.35 dB, the corrector still improves 100% of instances. The input noise is strongly heteroscedastic (spatial variance CV 1.26), which is precisely the structure exploited by the conditioned corrector.
Unseen solution structure. On a 500-case pack whose manufactured solutions use only atom types absent from the training dictionary, MC² reaches 42.32 dB median against 45.54 in-distribution, retaining 93% of its PSNR, while a training-free classical denoiser moves only dB (calibrating the pack's intrinsic difficulty) and the FNO operator collapses by dB to below the raw input.
Resolution shift. Applied without retraining at via tiled inference on 510 instances, the corrector improves every one of the 510 instances over its own raw field, and the paired median relative improves from 0.0189 to 0.0166.
Limitations.
We will expand this section to cover the dependence on the manufactured-solution distribution, the measured bias floor and crossover budget, and the tradeoff discussed under W3.
Thank you for the clarifications and the additional experiments. My main concerns are partially addressed. I will maintain my current score.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 2/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper introduces MC2, a hybrid PDE solver that uses a learned Swin-UNet to correct low-budget Walk-on-Spheres estimates. The model is trained against analytic solution fields and is intended to recover a more accurate solution from an early Monte Carlo estimate in a single forward pass. The paper also introduces PDEZoo, a procedurally generated benchmark of two-dimensional elliptic PDEs with manufactured analytic solutions, varied geometries, and Monte Carlo trajectories at several sampling budgets. The model is trained on Laplace, Poisson, and Yukawa problems, while biharmonic and Helmholtz problems are used to examine transfer to PDE families not seen during training. The experiments compare MC2 with higher-budget Walk-on-Spheres, classical denoisers, FNO/PINO, and diffusion-based PDE solvers, and report that MC2 with a budget-8 input approaches the accuracy of Monte Carlo estimates obtained with orders of magnitude more samples.
Strengths and weaknesses
Strengths
I found the basic motivation compelling. Monte Carlo PDE solvers are attractive because they are flexible, mesh-free, and approximately unbiased, but their variance makes them expensive at small sampling budgets. Using a learned model to improve an early estimate is a sensible idea, and a benchmark that includes analytic ground truth together with intermediate Monte Carlo solutions could be useful to the community. The data-scaling and input-budget studies are also relevant, and the conditional-mean interpretation gives a clean statistical description of the intended bias-variance tradeoff.
Weaknesses
1. I have several concerns about the technical validity of the current submission. The most important one concerns the held-out PDE families. The biharmonic problem is written as with only prescribed on the boundary. Since this is a fourth-order equation, one would normally need a second boundary condition. As written, the manufactured function is therefore not uniquely determined by the stated boundary-value problem. The Helmholtz case raises a related issue: uniqueness can fail at Dirichlet eigenfrequencies, but I could not find any spectral exclusion or discussion of near-resonant cases. More broadly, the appendix does not give the Walk-on-Spheres estimator, probabilistic representation, or correctness argument used for either biharmonic or Helmholtz problems. These are the two families used to support the OOD claim, so this missing information affects a central result rather than being a minor implementation detail.
2. I also do not think the theoretical discussion currently supports some of the language used in the main paper. The conditional expectation is indeed the population minimizer under squared loss, but this fact does not guarantee that the learned finite-data network improves on the raw estimator. Likewise, the Lipschitz argument establishes variance reduction only under the assumption that the corrector is contractive. The model is not constrained to be contractive, and no Lipschitz or Jacobian measurement is reported. The appendix defines the bias introduced by the corrector but does not bound it, and it explicitly stops short of proving asymptotic consistency. There is also a mismatch in the epsilon-shell analysis: Appendix B gives an rate, whereas Appendix F replaces this with and then in the MSE. The additional bias from terminating walks after a fixed maximum number of steps is not discussed.
3. A separate concern is that the experiments do not clearly separate correction of Monte Carlo error from learning the distribution of manufactured solutions. PDEZoo first samples from a relatively restricted dictionary of atoms and then derives and from that same . According to Sec. 5, MC2 receives both the noisy estimate and the source term. It can therefore use a strong prior over the target fields as well as information contained in . In addition, if independent walks are used at different grid points, the pointwise errors should be conditionally uncorrelated, although their variances may have a spatial pattern. I did not find an experiment with repeated independent realizations of the same PDE that demonstrates the claimed spatial correlation of the error. The comparison with Gaussian filtering, total variation, and non-local means does not resolve this issue, since a learned model may simply be much better at projecting onto the synthetic solution distribution. A useful ablation would compare the same architecture with only, only, and , and then test it on new atom families or independently generated numerical PDE solutions.
4. The baseline comparison also makes it difficult to identify what part of the gain is specific to MC2. The proposed model is a strong image-restoration architecture, but there is no learned U-Net, SUNet, Restormer, or similar denoiser trained with exactly the same input channels and Monte Carlo budget. FNO/PINO and the diffusion methods are given different information and solve somewhat different input-output problems. Their poor performance is therefore not a clean measure of the benefit of the proposed correction formulation. There is also substantial prior work on learned post-processing of low-sample Monte Carlo estimates in rendering, which seems closely related but is not discussed. I see potential originality in applying this idea to WoS and in releasing multi-budget trajectories, but the paper currently presents the broader denoising principle as more novel than it is.
5. Finally, I found substantial inconsistencies in the reported results. MC2 has an overall PSNR of 44.90 dB in Table 2, 44.10 dB in Sec. 5.3 and Table 11, and 44.48 dB in Table 12. The raw budget-8 WoS result is 15.26 dB in Table 2 but 25.54 dB in Sec. 5.3. FNO is reported as 7.74 dB in Table 2 and 30.34 dB in the discussion and Table 11. The MC2 results for biharmonic and Helmholtz are 35.96/40.05 dB in Table 3 but 34.88/35.87 dB in the discussion and appendix. There is a similar inconsistency in the method description: Sec. 3 defines the corrector using only , Sec. 5 uses , and Appendix F allows additional inputs. The PSNR range, normalization, masking, timing protocol, and meaning of the reported standard deviations are also not defined clearly enough. Until these points are reconciled, I do not know which experimental version supports the main claims.
My assessment could change if the authors can resolve the PDE formulation and solver questions, identify the definitive experimental results, and provide evidence that the model is correcting realization-specific Monte Carlo error rather than primarily exploiting the manufactured-solution prior.
Questions
1. Could the authors give the complete boundary conditions and the exact Monte Carlo estimators used for the biharmonic and Helmholtz cases? In particular, I would like to see the probabilistic representation or derivation, estimator pseudocode, treatment of Helmholtz eigenfrequencies, and convergence checks for these two families. A valid and reproducible construction would materially improve my assessment. If the biharmonic problem really uses only one boundary condition, or if these estimates are not produced by a valid WoS estimator, I do not think the present OOD claim is supported.
2. Which numerical results should be treated as definitive: Tables 2–3 or Tables 11–12 and the surrounding discussion? Could the authors provide a reconciled table and specify the exact input channels, training budgets, normalization, mask usage, checkpoint, and evaluation code used to produce it? The differences in FNO and Helmholtz performance are too large to be explained as rounding errors. My score could increase if the authors identify and convincingly resolve this experimental-version mismatch.
3. Could the authors report same-capacity ablations using only, only, PDE information only, and , preferably with the same SUNet backbone? Repeated independent WoS realizations for a fixed set of PDEs would also help determine whether the network is learning realization-specific error or mainly projecting onto the manufactured-solution distribution. Clear evidence for the former would improve my view of both the technical quality and originality.
4. Could the method be compared with at least one learned image-restoration baseline trained with exactly the same budget-8 field and auxiliary inputs? I would also appreciate a timing table measured on identical hardware and including both WoS generation and neural inference. Please clarify whether the claim refers to the number of Monte Carlo samples or to measured wall-clock time, and how the offline generation and training costs are amortized.
5. How are the PSNR data range, field normalization, interior mask, and LPIPS preprocessing defined, and what source of variability do the reported standard deviations represent? I would also like clarification on whether the held-out PDE families use new solution atoms or mainly the same target-function distribution. A small evaluation on unseen atom families or independently solved FEM/FDM problems would help establish whether the benchmark measures PDE-family generalization or denoising within a shared synthetic prior.
Limitations
The paper acknowledges that the method is limited by the applicability of the underlying Monte Carlo solver. It would also be helpful to discuss the extent to which performance depends on the manufactured-solution distribution, particularly given the OOD generalization claims, and to clarify that the theoretical variance-reduction argument is conditional and does not provide a general bias or consistency guarantee for the learned corrector.
Final justification
After considering the rebuttal and discussion, I raise my rating from 3 to 4.
The PDE formulations, matched baselines, input ablations, timing, and evaluation protocol were substantially clarified. The theory remains conditional and does not establish global contraction or asymptotic consistency. The checkpoint mixing, mislabeled baselines, and result-transfer errors still reduce confidence in the empirical evaluation, despite the reconciled results.
Overall, the new evidence outweighs the remaining concerns, but not enough to justify a stronger recommendation.
Formatting concerns
None
10 comments
Rebuttal
We thank you for your helpful feedback. We conducted new experiments by evaluating on the 5,000-instance test set using one A100 node, and address your comments as follows:
W5/Q2. Definitive results
We apologize for the earlier inconsistencies, as we included some numbers from older checkpoint runs and made mistakes when transferring our results into the tables. To resolve this we re-evaluated every method in a single run to conclude that Tables 2 and 3 are definitive. The run we did reproduces the raw Walk-on-Spheres, classical-denoiser, and MC² rows of both tables to the printed precision, including the standard deviations and the biharmonic and Helmholtz values you cite (35.96 and 40.05). The 44.10 dB prose figure and Appendix Table 11, including its 34.88 and 35.87 for biharmonic and Helmholtz, come from an earlier checkpoint and evaluation run, and Table 12's 44.48 dB is the row of the data-scaling ablation, which is a separate model rather than the headline checkpoint. On the FNO discrepancy, 7.74 dB (Table 2) is the operator configuration with input alone; the Discussion's 30.34 dB belongs to an FNO denoiser whose input is the WoS field and was mislabeled there, and a genuinely full-input FNO operator, retrained here, reaches 18.04 dB. The table below consolidates that run together with the additional baselines requested in the reviews, and every number in the camera-ready will be regenerated from it.
| Method (inputs) | PSNR med | PSNR mean | relative med | LPIPS med |
|---|---|---|---|---|
| Raw WoS | 13.91 | 15.26 | 0.919 | 0.683 |
| Non-local means (best classical) | 27.14 | 26.63 | 0.182 | 0.208 |
| FNO operator, full | 15.05 | 18.04 | 0.576 | 0.181 |
| PINO operator, full | 5.92 | 7.95 | 13.19 | 0.349 |
| U-Net, matched 99.6M params, | 38.44 | 37.32 | 0.038 | 0.042 |
| MC², single pass | 45.54 | 44.90 | 0.0178 |
How we computed the metrics: PSNR/SSIM use a per-instance frame set by the pooled min and max of the ground truth and the raw WoS input over interior (domain-masked) pixels, with the same frame applied to every method, relative is frame-independent, and reported spreads are across test instances. We will release the exact protocol and evaluation script and define PSNR range, normalization, masking, timing protocol, and meaning of the reported standard deviations with the camera-ready version.
Additionally, the per-family breakdown from this same run is as follows, reported as mean PSNR to match Table 3. MC² reaches 59.94 (Laplace), 42.17 (Poisson), 46.40 (Yukawa), 35.96 (biharmonic), and 40.05 (Helmholtz), against a raw input of 25.22, 11.20, 13.89, 15.01, and 10.93 respectively. The corrector improves 100% of biharmonic and Helmholtz instances (bootstrap CIs on the paired MSE difference below zero), with median MSE and against raw and .
W1/Q1. Held-out families.
We agree that these details are important and were inadvertently omitted. The problems and estimators used in our experiments are as follows.
Biharmonic. We use the Navier boundary conditions and on , with both and determined by the manufactured solution. The fourth-order problem is therefore well-posed and is solved as two Poisson problems: , , followed by , . At each source sample in the outer WoS estimator for , we run an independent inner WoS estimator for . Since the inner estimate is unbiased, the tower property gives , and averaging independent samples gives variance .
Helmholtz. For with on , we use the exact two-dimensional ball identity
where
Each WoS step samples the boundary term and the volume-source term from this identity.
We explicitly exclude Dirichlet resonances. Across all Helmholtz instances, , while the smallest first Dirichlet eigenvalue is . Computing separately for each instance, the minimum ratio is , so every instance is more than a factor of two below the first resonance. We also cap the WoS radius at , giving . Hence and , preventing singular step weights and ensuring finite variance.
We additionally performed the following convergence checks. For biharmonic problems with and a -step cap, no walk reached the cap. The median walk length was and the maximum was . Results were unchanged when the cap was reduced to . Sweeping changed the error by less than at every tested budget. Increasing the budget from to reduced the error by a factor of , consistent with the predicted .
Finally, fitting median MSE against budget gave log–log slopes of , , , and for Laplace, Poisson, Yukawa, and Helmholtz, respectively, with . Biharmonic fitting yielded a slope of up to and flattened only beyond , where discretization and -shell errors dominate Monte Carlo variance. This is roughly above the operating budget used in our evaluation.
We will add the complete boundary conditions, probabilistic derivations, estimator pseudocode, resonance checks, and convergence results to the revised camera-ready appendix.
W2. Theory.
We agree that the population conditional-expectation result does not guarantee improvement by our finite-data network, and that our original contractivity and consistency language was too strong. We will revise these claims and report the following measurements.
-
Contraction. The network is not globally contractive: over 50 instances, the local Jacobian norm has median and maximum . However, along paired-seed perturbations representing the directions of actual WoS noise, the median gain is , with all measured gains below . Moreover, gain$^2\approx1.4\times10^{-4}$ agrees with the independently measured variance ratio . We will therefore replace the global contractivity assumption with this measured noise-direction contraction.
-
Bias–variance tradeoff. On the evaluation seed pack, no meaningful bias is detected for raw WoS. We observe that median bias$^2$ is , compared with a mean variance of . The corrector reduces variance to while introducing bias$^2=0.0269$, yielding total MSE instead of , a reduction.
-
High-budget behavior. We do not claim asymptotic consistency. The corrected estimator remains better at every tested budget, including by at , which is the operating budget. It improves 100% of instances through , 92.9% at , and at . Its high-budget plateau, approximately , agrees with the measured clean-input bias floor. Extrapolating the raw rate places the crossover near walks/grid point. We will state this bias floor and remove any stronger consistency claim.
-
-shell error. We will correct the mismatch between Appendices B and F and consistently use the correct error rate. Empirically, varying over three orders of magnitude changes the error by less than at every tested budget.
-
Maximum-step truncation. As mentioned above, no walk reaches the -step cap, the maximum observed length is , and outputs are bit-identical with a cap of . Thus, no truncation bias is observed in our evaluation.
Continued in reply
Rebuttal Part 2
W3/Q3. Realization-specific correction vs. prior fitting.
Thank you for suggesting these experiments. We ran both.
Same-capacity four-configuration ablation. We use one 4-channel SUNet with 99,682,857 parameters in every configuration, with unavailable channels zeroed at train and evaluation time, so parameters, initialization, data, and schedule are bit-identical and only information content varies. All four configurations were trained using one matched 40-epoch schedule.
| Configuration (visible inputs) | PSNR med | relative med |
|---|---|---|
| , the MC² configuration | 44.29 | 0.0207 |
| only (no PDE information) | 40.56 | 0.0289 |
| only (prior, no observation) | 9.29 | 1.549 |
| (full specification, no observation) | 8.56 | 1.659 |
The observation-free configurations score below the raw input itself (8.6/9.3 vs. 13.9 dB median). With the full PDE specification and the paper's own atom dictionary but no Monte Carlo observation, the network cannot reconstruct , so it is not a solution-prior lookup. The -only configuration reaches 40.6 dB with zero PDE information, 31 dB above the best observation-free configuration. we also see that adding contributes a further dB. The ranking is what the corrector hypothesis predicts and the opposite of the prior-fitter prediction.
Repeated independent realizations. We evaluated 300 fixed instances (60 per family) 10 independent WoS seeds at . Mean spatial autocorrelation of the error at lags 1–8 px is (per-case max 0.018), supporting your independence argument. We will replace "spatially correlated noise" in the camera-ready with the measured mechanism, a strongly heteroscedastic variance field (spatial CV 1.26) over a smooth signal, which is precisely the structure the conditioned corrector exploits. The correction is realization-specific rather than a per-instance constant. The per-seed error gain has median 0.011 (p95 0.037, 100% below 1), so the corrector removes of each individual realization's stochastic error, and its output variance across seeds is strictly positive (variance ratio , mean ).
Unseen atoms. You are correct that Table 3's OOD axis is the operator (fourth-order, indefinite) and that the held-out families draw from the training atom dictionary; we will state this explicitly in the camera-ready. To test the atom axis directly, we built and evaluated a fresh 500-case pack (100 per family) whose manufactured solutions use only atom types absent from the training dictionary. The general pool includes Gabor wavelets, radial ripples , Hermite-lobed Gaussians, angular petal rings, and radial chirps . The harmonic pool for Laplace includes multipoles , essential singularities , rotated complex-frequency modes , and , each verified harmonic to in fp64. We use the same protocol and report median PSNR at .
| Method | standard pack | unseen atoms | |
|---|---|---|---|
| Non-local means (training-free ruler) | 27.14 | 26.70 | |
| FNO operator | 15.05 | 7.27 | |
| U-Net , matched | 38.44 | 35.46 | |
| -only configuration | 40.56 | 38.15 | |
| MC² | 45.54 | 42.32 |
We believe this provides a clear separation between correcting the estimate and fitting the prior. The training-free denoiser calibrates the pack's intrinsic difficulty at dB, so the shift itself is small. The operator baseline, which maps the PDE specification directly to the solution and therefore leans entirely on the solution prior, collapses by 7.8 dB to below the raw input on the same pack (14.92 dB). The observation-driven corrector loses 3.2 dB, retains 93% of its PSNR, remains 27 dB above its own input, and still improves with budget on the new atoms (42.3 dB at rising to 53.2 dB at , while the raw WoS input keeps converging at the expected Monte Carlo rate of in relative ). A prior-fitter would be expected to collapse in the way the operator does, whereas MC² does not. An additional evaluation against independently solved FEM/FDM references will be added to the camera-ready.
Rebuttal Part 3
W4/Q4. Matched baselines, related work, timing.
Thank you for requesting these comparisons and clarifications. (a) We trained two capacity- and information-matched learned denoisers. A plain U-Net at 99,559,507 parameters ( MC²), with identical inputs, data, and schedule, reaches 38.44 dB, 5.85 dB below the same-schedule MC² configuration and 7.1 dB below the headline checkpoint. An FNO at 99,799,229 parameters ( MC²) with the same inputs reaches 32.00 dB. The latter comparison directly isolates the requested effect because it holds the architecture family fixed and varies only the formulation.
| Type | params | PSNR med |
|---|---|---|
| FNO with operator formulation | 16.8M | 15.05 |
| FNO with correction formulation | 99.8M | 32.00 |
| MC² | 99.7M | 45.54 |
Swapping the formulation inside a single architecture family is worth dB, larger than the dB architecture premium that remains. Conditioning on the stochastic estimate, rather than capacity or architecture, is the single largest factor, which directly addresses the requested fairness comparison. We note that the FNO data pipeline trains on Laplace, Poisson and Yukawa (the released-baseline convention, shared with the operator run, so the dB comparison is internally consistent); on those three families it scores 35.3 median against MC² at 40–46, so the architecture gap remains on its supported families.
(b) We will add the rendering literature on learned post-processing of low-sample Monte Carlo estimates (Rousselle et al.; Bako et al., KPCN; Chaitanya et al.; Gharbi et al., SBMC) to Related Work, and rescope the novelty claim to the WoS/PDE instantiation, the train-once single-pass setting, and the multi-budget trajectory dataset release.
(c) We measured timing end to end on one idle A100, with batch 1 for both stages. WoS at costs 0.891 s standalone; the corrector forward pass takes 30.0 ms ( of runtime); and end-to-end runtime is 0.92 s. WoS first matches MC² quality at , costing 200.5 s. Our Contribution 1 currently states a "more than 1000x wall-clock speedup," and we agree that this is an overstatement that should be corrected. The measured figures on identical hardware are fewer Monte Carlo iterations and wall-clock, and the camera-ready will state the two separately rather than conflating them. We also identified an accounting issue in the opposite direction. The published WoS cost (1.845 s) was a walk_batch=256 accounting artifact that credited the first 256-walk chunk to every budget at or below 256; a standalone solve costs 0.891 s, so the true wall-clock ratio is larger than a naive recomputation from the published table would give. Data generation and training are one-time costs amortized across the problem distribution (train once, correct any WoS-solvable instance zero-shot). Current compute required is 64.03 GFLOP/forward and 685 MiB peak memory on one A100 GPU. A camera-ready compute appendix will report the full timing table.
Q5. Definitions.
Thank you for asking us to clarify these definitions. We will fix them in the evaluation-protocol subsection of the camera-ready. PSNR is computed in the min–max frame over interior (masked) pixels; frame-independent relative is reported alongside; standard deviations are across test instances; and the timing protocol (single GPU, batch 1, warm start, per-stage breakdown) will also be specified. The atom question is addressed under W3.
Limitations.
We will expand this section in the camera-ready to state the dependence on the manufactured-solution distribution, the measured rather than guaranteed nature of the variance reduction, and the corrector's bias floor with the crossover budget above.
Conclusion Once again, thank you so much for your very detailed review and helpful feedback to improve our paper. We believe your three conditions regarding valid held-out formulations, definitive results, and evidence of realization-specific correction are addressed above with direct measurements, and we welcome any further questions during the discussion period.
Comments on the paper
2 comments
Overall Authors Comments 1
We thank all reviewers for their thoughtful engagement with our work. Reviewer Mpjh found the motivation compelling and described our method as a sensible idea. Reviewer fT9n called the core approach simple yet powerful, while Reviewer ydGg described the problem as meaningful and practically relevant and the correction framework as conceptually appealing. Reviewer G9Js further highlighted that the results on held out PDE families indicate that MC² generalizes remarkably well, and described PDEZoo as a potential cornerstone for future research.
We summarize our responses to the reviewers' concerns below.
Reliability of the empirical evaluation. Reviewer Mpjh highlighted inconsistent values in the submitted paper. We agree that mixing results from an older checkpoint, a separate data-scaling model, and a mislabeled FNO corrector was confusing.
To address this, we reconstructed the evaluation through one pipeline on the fixed 5,000-instance test set, using one headline checkpoint, test manifest, metric implementation, and A100 configuration. Tables 2–3 are definitive and are reproduced when we reran it, including the biharmonic and Helmholtz values. Each conflicting value has been traced to a specific previous run rather than unexplained numerical variation. We will revise all tables and figures in the camera ready version and release the checkpoint identifier, manifest, evaluation code, normalization and masking protocol, and per-instance predictions.
We show that the central result is not an artifact of an aggregate metric or favorable subset, with MC² improving almost all evaluated instances, with statistically significant improvement for every PDE family. We take Reviewer Mpjh's remaining concern seriously, but believe that our transparent results, protocol and code release make all our results fully reproducible.
Validity of the held-out PDE experiments. Reviewers Mpjh and fT9n noted that the initial submission didn't fully specify the biharmonic boundary conditions or Helmholtz estimator. In our experiments, biharmonic instances use the Navier conditions () and (), evaluated through a nested two-Poisson WoS estimator. Helmholtz instances use the exact two-dimensional ball Green's-function representation. We explicitly exclude Dirichlet resonances and cap the radius below the first zero of . The measured errors follow the expected Monte Carlo convergence rate over the relevant budget range. Furthermore, no evaluated walk reaches the truncation cap and the results are stable under changes to the -shell.
Theoretical scope. Additionally, we agree that our original theoretical language was too broad. Conditional-mean optimality is a population statement, and MC² is not necessarily globally contractive nor does it preserve unbiasedness. However, the standard bias–variance decomposition gives a precise condition for finite-budget improvement:
In other words, MC² improves MSE whenever the variance reduction exceeds the additional squared bias introduced. Our further experiments show this condition holds at our tested operating budgets: raw WoS has negligible measured bias, while MC² substantially reduces its variance and total MSE. MC² improves every single test instance at the operating budget (B=8) and remains beneficial across all tested budgets, including well beyond its training range. At high budgets, the corrected error plateaus near the error obtained when the exact solution is passed through the corrector, while raw WoS continues to improve at the expected Monte Carlo rate. The revision will present this finite-budget improvement condition together with the measured bias–variance tradeoff, repeated-seed variance reduction, high-budget plateau, and estimated crossover with raw WoS.
Overall Authors Comments 2
Correction of Monte Carlo error vs. fitting a synthetic prior. Reviewers Mpjh and ydGg questioned whether the network primarily reconstructs solutions from the PDEZoo distribution rather than correcting Monte Carlo error. To address this, we ran a bit-identical-capacity ablation using one SUNet with unavailable channels zeroed. The full corrector reaches 44.29 dB and the WoS-only configuration reaches 40.56 dB median PSNR, whereas the observation-free -only and full PDE specification configurations reach only 9.29 and 8.56 dB, both below the raw WoS input. Thus, access to the manufactured PDE specification is insufficient without the stochastic observation.
Furthermore, we conducted repeated seed experiments that show the corrected output varies with and removes error from each individual WoS realization. We also constructed a new 500-instance test set containing only solution-atom families absent from training. On this test set, MC² retains a median PSNR of 42.32 dB, whereas the FNO operator falls below the raw input. We will clarify that the original held-out family experiment probes model transfer across PDE operators, while this new experiment separately tests transfer across solution structure.
Fair baselines and new metrics. Reviewers Mpjh, ydGg, and fT9n noted that the original FNO/PINO baselines may have been information-starved. To address this, we added capacity and information matched baselines. A U-Net with equal parameter count reaches a median PSNR of 38.44 dB and a matched FNO corrector reaches 32.00 dB, compared to the 45.54 dB for MC². Within the FNO family, changing from the direct operator prediction to input correction raises median PSNR from 15.05 to 32.00 dB. This shows that conditioning on the low-budget Monte Carlo observation is itself a major source of improvement, while the Swin backbone provides a further gain.
To better assess the benefits of MC², we also added PDE-centric metrics, a comparison with Neural Walk-on-Spheres, different resolution experiments, and hardware timing. E2E MC² inference takes 0.92 s, while raw WoS first reaches comparable accuracy at 200.5 s. We will update our final paper version with separate measured statements about Monte Carlo sample reduction and the approximately wall-clock speedup.
We would like to thank the reviewers again for their time in reviewing our work and providing valuable feedback.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
AC Response Part 1
We thank the AC for summarizing the strengths of the paper and identifying the four most important concerns. We are encouraged that the reviewers found the motivation compelling, the approach simple and effective, the transfer to unseen PDE families promising, and PDEZoo as a potentially useful dataset to the community. We summarize our response to each concern below, with our full responses being located under the corresponding reviewers' comments.
1. Fairness of the baseline comparisons. We agree that the original FNO and PINO comparisons did not fully isolate the effects of input information, formulation, and architecture. We therefore added information and capacity matched baselines. A 99.6M-parameter U-Net trained with the same inputs, data, and schedule reaches 38.44 dB median PSNR, while a 99.8M-parameter FNO corrector reaches 32.00 dB, compared with 45.54 dB for MC². Within the FNO family, changing from direct operator prediction to correction raises median PSNR from 15.05 to 32.00 dB, directly isolating the value of conditioning on the low-budget WoS realization.
We also performed a bit-identical-capacity input ablation. The full (uB,f) model reaches 44.29 dB, while uB alone reaches 40.56 dB. In contrast, the observation-free f-only and full-PDE-specification configurations reach only 9.29 and 8.56 dB, both below the raw WoS input. These results show that the gain is not explained solely by additional PDE information or solution-prior fitting.
2. Timing, memory, and ablations. We measured the complete inference pipeline on one idle A100 at batch size one. MC² has 99.68M parameters, requires 64.03 GFLOP per forward pass, and uses 685 MiB peak inference memory. Budget-8 WoS takes 0.891 s, the corrector takes 30 ms, and end-to-end inference takes 0.92 s. Raw WoS first reaches comparable accuracy at 200.5 s on the same hardware.
We will therefore replace the ambiguous "1000× faster" statement with separate measured claims for Monte Carlo sample reduction and approximately 218× wall-clock speedup at matched accuracy. The revision will include the complete timing ladder, hardware and batching details, model memory and compute, and the matched architecture and input ablations above.
3. Missing modern baselines. We added Neural Walk-on-Spheres using its official implementation on a pre-registered subset of Poisson problems (which we chose since this is the primary class of problem that NWoS supports). NWoS trains separately for each PDE instance and requires a median of 376 s per instance, whereas MC² performs train-once, zero-shot correction and obtains lower error in 1.56 s on the same cases.
We will also expand Related Work to discuss BVC, NCV-AI, WoS-NO, and learned Monte Carlo post-processing in rendering. We will narrow the novelty claim accordingly: neural denoising itself is not new. Our contribution is the WoS/PDE correction formulation, amortized train-once and single-pass inference across a problem distribution, and PDEZoo's release of analytic solutions with multi-budget WoS trajectories.