potentialpaper

Accuracy of Noise Ceiling Estimators for Brain Scores

Aude Maier, Lucas Gruaz, Martin Schrimpf, Johanni Brea

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

Abstract. The internal activations of modern machine learning models align surprisingly well with the activities recorded in real brains. In the last five years, the alignment between encoding models and brain activities, often called brain scores, has steadily increased. Because brain recordings are noisy, there exists an upper bound to the brain scores that any model can achieve. This bound, called the noise ceiling, is crucial for two reasons: it determines whether further improvements in model performance are possible, and it enables meaningful comparisons of brain scores across benchmarks. The field has developed multiple approaches to estimate noise ceilings, but the statistical properties of existing estimators remain poorly understood, leaving it unclear in which experimental settings they provide reliable estimates. Here, we introduce a unified mathematical framework for brain recordings, use it to derive closed-form expressions for four commonly used noise ceiling estimators, and provide theoretical predictions for the behavior of each estimator. We validate the theoretical predictions with simulations that we compare to noise ceiling estimates in existing fMRI and EEG datasets. We find that the existing methods underestimate the true noise ceiling in different settings. We conclude with recommendations for best practice in different situations.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
5 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]—[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:43 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

Comments after Rebuttal: The authors provided a thorough rebuttal and all reviewers now view the paper as above bar for acceptance. I have raised my recommendation accordingly.

Comments before Rebuttal: This paper tackles an important and under-served subject and two of the three initial reviews view it as above the bar for acceptance. Before fully recommending acceptance I would like to see further discussion and ideally a consensus among the three reviewers. In particular, all of the reviewers noted that empirical validation was rather limited and it is expected that the proposed method would perform well in simulations that match its assumptions.

I would like to see a clear rebuttal responding to the weaknesses raised in the initial review, in particular:

  • Reviewer fVZK's comment on finite-sample bias
  • Reviewer fVZK's comment on LOOP baseline
  • Including a dedicated section on the method's limitations
  • Expanded validation through new datasets or further simulations where model assumptions are challenged.
Final justification

The authors provided a thorough rebuttal and all reviewers now view the paper as above bar for acceptance. I have raised my recommendation accordingly.

Area Chair jZ2L · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

Comments after Rebuttal: The authors provided a thorough rebuttal and all reviewers now view the paper as above bar for acceptance. I have raised my recommendation accordingly.

Comments before Rebuttal: This paper tackles an important and under-served subject and two of the three initial reviews view it as above the bar for acceptance. Before fully recommending acceptance I would like to see further discussion and ideally a consensus among the three reviewers. In particular, all of the reviewers noted that empirical validation was rather limited and it is expected that the proposed method would perform well in simulations that match its assumptions.

I would like to see a clear rebuttal responding to the weaknesses raised in the initial review, in particular:

  • Reviewer fVZK's comment on finite-sample bias
  • Reviewer fVZK's comment on LOOP baseline
  • Including a dedicated section on the method's limitations
  • Expanded validation through new datasets or further simulations where model assumptions are challenged.
Final justification

The authors provided a thorough rebuttal and all reviewers now view the paper as above bar for acceptance. I have raised my recommendation accordingly.

4 comments
Authors · CommentOpenReview ↗

Response to the Area Chair (1/3)

We thank all the reviewers for their very helpful comments and suggestions and the Area Chair for the clear synthesis. We address the four requested points below.

Comment on the code release: Even though the pdf of the paper does not include a link to the code repository, the code was uploaded at the time of submission as supplementary material and can be downloaded directly on OpenReview. The repository has now been made available at https://anonymous.4open.science/r/noise-ceiling-0FE1, and has been updated to include all new results requested by the reviewers. The data is hosted separately at https://osf.io/2btpr/?view_only=6a9a67ebc6aa4426a48321c880fa41be and can be downloaded with the script provided in the repository. We will also include a link to the code repository in the final version of the paper.

(1) Finite-sample bias

NC^SH\widehat{NC}^{\text{SH}}, NC^LOOC\widehat{NC}^{\text{LOOC}}, NC^TTMC\widehat{NC}^{\text{TTMC}}, NCsingle{NC}^{\text{single}} and NCmean{NC}^{\text{mean}} all share the same form: a Pearson correlation between two arguments, each a single trial vi(ℓ)\mathbf{v}_i^{(\ell)}, its noise-free component vi(ℓ)∗{\mathbf{v}_i^{(\ell)}}^*, or the mean of these quantities over a subset of trials. The expected value of the Pearson correlation converges to the population correlation at rate O(1/T)\mathcal{O}(1/T). However, the convergence requires fast decaying autocorrelations of the signals, which is often challenged in fMRI data because of drift and undamped oscillations. This assumption must therefore be empirically verified before computing noise ceiling estimators. Long-range autocorrelations can be mitigated by high-pass filtering the data.

NC^SHSB\widehat{NC}^{\text{SHSB}} and NC^SNR\widehat{NC}^{\text{SNR}} require an additional second-order Taylor expansion, which also results in a bias term of order O(1/T)\mathcal{O}(1/T). Because the max function is not differentiable at zero, the expansion is valid only when the distribution of the argument of the max function is strictly positive. As the noise ceiling approaches zero, this distribution is no longer strictly positive, and the Taylor expansion is no longer valid. The leading order term of the bias is then O(1/T1/4)\mathcal{O}(1/T^{1/4}), as it was shown in Appendix B.2 and B.3.

We validated the 1/T1/T convergence of the finite-sample bias on the synthetic data using a log-log plot of the bias as a function of T∈[101,103]T\in[10^1, 10^3] for all estimators and true noise ceilings. Using a linear fit, 5 estimators yield a slope whose confidence interval includes −1-1. The three remaining quantities have a slope between −1-1 and −1.2-1.2, which can be due to interference from the higher order terms.

Additionally, we checked the convergence rate in the Sherlock fMRI dataset (V1 and IT) by plotting each estimator as a function of TT and fitting A+B⋅TpA + B\cdot T^p to the data. The confidence intervals of the fitted exponent pp contained −1-1 for all estimators, except for NC^SNR\widehat{NC}^{\text{SNR}} and NC^SHSB\widehat{NC}^{\text{SHSB}}. For these two estimators, the power is of higher order (SHSB [V1: −0.81-0.81, IT: −0.13-0.13] and SNR [V1: −1.08-1.08, IT: −0.53-0.53]) and approaches −1-1 when only including voxels with high noise ceilings. This is consistent with having a mix of voxels with 1/T1/T and 1/T1/41/T^{1/4} convergence rates. This interpretation also predicts the pattern we observe: the fitted exponent is closer to −1/4−1/4 in IT than in V1 for both estimators, as expected from IT's lower noise ceiling and correspondingly larger fraction of voxels in the non-differentiable regime.

Authors · CommentOpenReview ↗

Response to the Area Chair (2/3)

(2) LOOP estimator

Let vi(ℓ)\\{\mathbf{v}_i^{(\ell)}\\} be a set of recordings from different subjects ℓ∈1,..,n\ell\in\\{1,..,n\\} and channels i∈1,...,mi\in\\{1,...,m\\}. We define χ(−ℓ):=spanvi(ℓ′):ℓ′≠ℓ, ∀i\chi^{(-\ell)}:=\mathrm{span}\\{\mathbf{v}_i^{(\ell')}: \ell'\neq\ell,\,\forall i\\}. Note that the signals ϕk\boldsymbol{\phi}_k that are part of vi(ℓ′)=∑kw(ℓ′)[i,k],ϕk+ηi(ℓ′)\mathbf{v}_i^{(\ell')}=\sum_k w^{(\ell')}[i,k]\\,\boldsymbol{\phi}_k + \boldsymbol{\eta}_i^{(\ell')} are not necessarily contained in χ(−ℓ)\chi^{(-\ell)}. In particular, in the case where K>m(n−1)K>m(n-1) the linear transformation W(−ℓ)\mathbf{W}^{(-\ell)} is not invertible and ϕk∉χ(−ℓ)\boldsymbol{\phi}_k\notin\chi^{(-\ell)}.

In the limit T→∞T\to\infty, the prediction v^i(ℓ)\widehat{\mathbf{v}}_i^{(\ell)} is given by P(−ℓ)vi(ℓ)P^{(-\ell)}\mathbf{v}_i^{(\ell)}, with P(−ℓ)P^{(-\ell)} the orthogonal projection onto χ(−ℓ)\chi^{(-\ell)}. One can then show that the LOOP estimator is equal to

NC^iLOOP=Corrt(P(−ℓ)vi(ℓ),vi(ℓ))=∥P(−ℓ)vi(ℓ)∗∥∥vi(ℓ)∗∥,NCisingle≤NCisingle.\widehat{NC}_i^{\text{LOOP}}=\mathrm{Corr}_t\left(P^{(-\ell)}\mathbf{v}_i^{(\ell)}, \mathbf{v}_i^{(\ell)}\right)=\frac{\|P^{(-\ell)}{\mathbf{v}_i^{(\ell)}}^\ast\|}{\|{\mathbf{v}_i^{(\ell)}}^\ast\|} \\, {NC}^{\mathrm{single}}_i \leq {NC}^{\mathrm{single}}_i.

As a consequence, whether the LOOP estimator converges to the true noise ceiling as n→∞, nT→0n\to\infty, \, \frac{n}{T}\to 0 depends fully on the distribution of the weights w(ℓ)[i,k]w^{(\ell)}[i,k].

At finite TT, the above equation has an additional bias term of order O(1/T)\mathcal{O}(1/T) and, most importantly, a generalization error reduces LOOP further as OLS cannot find the optimal projection. The generalization error is mitigated, but not eliminated, by using ridge regression instead of OLS.

Whether LOOP performs better than LOOC depends on the trade-off between (1) how much larger the angle between χ(−ℓ)\chi^{(-\ell)} and vi(ℓ)∗{\mathbf{v}_i^{(\ell)}}^\ast is than the angle between vˉi(−ℓ)\bar{\mathbf{v}}_i^{(-\ell)} and vi(ℓ)∗{\mathbf{v}_i^{(\ell)}}^\ast, and (2) how large is the decrease caused by the generalization error. As they both are lower bounds of the true single-trial noise ceiling, we recommend computing both and reporting the maximum of the two.

As requested by reviewer fVZK, we added LOOP to the synthetic data and the Sherlock fMRI dataset results. LOOP is significantly higher than LOOC in all analyzed brain regions, except for the amygdala where they are similar.

(3) Limitations section

Here is a more detailed discussion of the limitations of our work, which we will include in the paper as a limitations section:

While our framework provides a unified theoretical grounding for noise ceiling estimation, several theoretical and empirical limitations remain. Theoretically, our model assumes linear mixing between shared latent signals and recording units. While well-motivated for fMRI hemodynamic responses and electroencephalography (EEG) linear sensor projections, this linearity assumption may break down in strongly non-linear measurement regimes. Furthermore, our derivations focus exclusively on encoding models and do not extend to Representational Similarity Analysis (RSA), for which the noise ceiling is defined differently and therefore the estimators' biases and convergence properties differ. Additionally, although we provide initial theoretical analysis for Leave-One-Out Prediction (LOOP), a complete theoretical treatment remains open: we currently lack a closed-form expression for its generalization error and a characterization of the convergence of the target signal to the span of the other subjects' signals based on the distribution of the mixing weights.

Empirically, our evaluation is restricted to fMRI and EEG modalities, leaving invasive electrophysiology (such as single-unit or multi-unit spiking activity) and magnetoencephalography (MEG) unexamined. Our empirical evaluation is further limited to visual (THINGS fMRI and THINGS EEG) and audiovisual stimulus paradigms (Sherlock fMRI), without validating performance in other cognitive domains such as natural language processing or motor control. Finally, our empirical validation relies on consistency checks of the closed-form expressions using synthetic data generated under a particular case of our theoretical framework, and qualitative comparisons across three datasets, rather than an exhaustive quantitative benchmark across diverse experimental and synthetic setups.

Authors · CommentOpenReview ↗

Response to the Area Chair (3/3)

(4) Expanded validation

We agree that a validation of the within-subject repetition case using a second fMRI dataset is needed. Although reviewers fVZK and dygq suggested using the NSD dataset, it is not suitable for our purpose because it contains only 3 repetitions per image, therefore we cannot observe the estimators' trend as nn grows. Instead, we chose the THINGS fMRI1 dataset, which contains 12 repetitions per image and is also standard in the field. This new dataset also generalizes our results to a different type of data, as it is obtained using a GLM instead of being raw fMRI signals. We ran all noise ceiling estimators on this dataset and compared them to the synthetic results of Figure 2. The results precisely match the predictions from the synthetic data and theory: NC^SHSB\widehat{NC}^{\text{SHSB}} and NC^SNR\widehat{NC}^{\text{SNR}} overlap and increase with nn, while NC^TTMC\widehat{NC}^{\text{TTMC}} and NC^LOOC\widehat{NC}^{\text{LOOC}} converge to the same value from above and below, respectively.

Additionally, following reviewer dygq's suggestion, we included an EEG dataset (THINGS EEG2) to validate the results beyond fMRI. This dataset contains 80 repetitions per image. The results are qualitatively similar to THINGS fMRI1 but with much lower values for all estimators despite the numerous repetitions, as expected from EEG data which is known to have very low signal-to-noise ratio. The recommendations do not change between fMRI and EEG data, as this dataset confirms that the relative ranking and trends of the estimators are preserved in EEG data.

We have addressed here all the points raised by the Area Chair, and will respond to the remaining questions from each reviewer directly. The new results support both the theoretical predictions and the practical recommendations of the paper, and together with the additional theory we believe they make the paper substantially stronger. We thank the reviewers and the Area Chair for the comments that led to these improvements, and we look forward to sharing our results with the broader community.

Authors · CommentOpenReview ↗

We would like to flag one addition since our response above, which completes our answer to the fourth point.

Our earlier response addressed the expanded validation through new datasets (THINGS fMRI1 and THINGS EEG2). We have since added the second half of that request: simulations in which the assumptions of our theoretical framework are challenged. We identified the assumptions our theoretical framework rely on and implemented three mechanisms that break part of them: (1) a distinct HRF per subject and per voxel, so that the signals entering the mixture are no longer shared across trials in the recorded space; (2) replacement of the synthetic noise by real fMRI recordings, taken from the Sherlock dataset and time-shifted independently per subject to remove the stimulus-driven component; (3) slow drift and oscillations shared across trials. Each mechanism is constructed so that the noise-free component remains exactly known, so the true noise ceiling can still be computed even where the closed forms no longer hold. We additionally discuss the assumptions we could not test and which ones our conclusions actually require.

The conclusions of the paper are unchanged under all three mechanisms. The full description is in our response to Reviewer dygq, under "Alternative fMRI generative models".

Reviewer DzjbOpenReview ↗
Rating
5/6
Confidence
5/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper considers the problem of estimating noise ceilings for brain scores, upper bounds on the performance that encoding models can achieve given noisy neural recordings. The authors propose a unified mathematical framework for trial-based brain recordings and use it to analyse several commonly used noise-ceiling estimators. Under this framework, they derive closed-form expressions or asymptotic characterisations showing how these estimators behave in within-subject and across-subject settings, and when they are expected to be biased. The authors validate their theoretical predictions using synthetic fMRI-like simulations, and compare the resulting estimator behaviour to real fMRI data (Sherlock dataset) across several brain regions. In addition, the paper proposes an AIC-based procedure for identifying signal-carrying recording units and concludes with practical recommendations for which estimators to use in different experimental regimes.

Strengths and weaknesses

This is a useful and timely paper that addresses an important methodological problem in NeuroAI and computational neuroscience: how to estimate noise ceilings for brain scores in a way that supports meaningful comparison across models, datasets, regions, and experimental settings.

The paper is generally clear and well motivated. The synthetic experiments support the theoretical analysis, and the "Sherlock" analysis helps to connect the framework with real fMRI data. I also appreciate the practical recommendations and the proposed AIC-based procedure for identifying signal-carrying units before computing noise-normalised scores.

To offer constructive criticism, my main reservations concern scope and practical usability.

  1. Although the framework is presented as broadly applicable across recording modalities (the paper explicitly mentioning fMRI, EEG, and MEG), the empirical analyses are limited to fMRI. How do the assumptions and recommendations transfer to EEG and MEG (where temporal autocorrelation, sensor/source mixing, trial structure, and alignment issues may differ substantially)? Even a small non-fMRI demonstration (e.g. EEG-only) would go far to strengthen the paper's impact.

  2. One of the most important conclusions is that no existing estimator is reliable in regions with large between-subject variability. This is a valuable diagnosis, but the paper could do more to give actionable guidance for precisely this difficult setting.

  3. Probably the main estimators are specified clearly enough, but the AIC-based signal-unit selection procedure involves practical choices such as split-half sampling, fitting the (1/(1+α/n))(1/(1+\alpha/n)) trend, choosing the tolerance parameter, and handling finite-sample uncertainty. A reference implementation would help researchers apply the recommendations consistently.

Finally, a more minor suggestion: The real-data validation (Sherlock analyses) are useful, but mainly qualitative, with synthetic parameters chosen to mimic empirical behaviour rather than being quantitatively fit and tested. This could be strengthened.

Questions
  1. The framework is presented as broadly applicable across recording modalities, with discussion of fMRI, EEG, and MEG. Could the authors clarify which assumptions are required for applying the estimators to EEG/MEG data, especially given differences in temporal autocorrelation, sensor/source mixing, trial structure, and alignment? A small non-fMRI demonstration, if feasible, would substantially increase the practical impact of the paper.

  2. In regions with large between-subject variability, the paper concludes that no existing estimator provides a reliable estimate of the relevant noise ceiling. What should practitioners do in this setting? For example, should they report bounds rather than point estimates, include specific diagnostics, avoid normalised brain scores, or prioritise within-subject repetitions where possible? Clearer guidance here would make the paper more actionable.

  3. Could the authors provide code or a more detailed implementation recipe for the estimators and the AIC-based signal-unit selection procedure? In particular, it would be helpful to specify practical choices such as the number of split-half samples, how to fit the (1/(1+α/n))(1/(1+\alpha/n)) trend, how to choose the tolerance parameter, and how to handle finite-sample uncertainty.

  4. The real-data analysis on the Sherlock dataset is useful but mostly qualitative, with synthetic parameters chosen to mimic empirical behaviour. Could the authors strengthen this by quantitatively fitting the generative model to real data, or by reporting a more explicit goodness-of-fit / predictive check? This would clarify how well the proposed framework captures real recordings beyond qualitative agreement.

A stronger response on questions 1-3, especially clearer guidance for high between-subject variability regimes and practical implementation details, would increase my confidence in the paper’s impact and usability.

Limitations

The paper is generally careful about the limitations of existing noise-ceiling estimators, and the authors are clear that no existing estimator is reliable in regions with large between-subject variability.

That said, the limitations of the proposed framework itself could be discussed more explicitly. In particular, the paper could clarify the scope of its assumptions for non-fMRI modalities such as EEG and MEG; discuss the practical limitations of the AIC-based signal-unit selection procedure; and provide more actionable guidance for practitioners working in high between-subject-variability regimes.

As discussed above, I would also encourage the authors to discuss whether code will be released, since implementation details are important for consistent use of the proposed recommendations.

Final justification

Thanks to chairs and to the other reviewers - it was helpful to read your reviews.

I updated the contribution type from "Theory" to "General" to match what the authors selected, though I think "Theory" would have been a better fit. I chose not to lower my score under the recategorisation, though it's possible my rating would have been lower had I not originally approached the work as a "Theory" paper.

I can see that my rating (5: Accept) is more positive than the other reviews (4: Borderline Accept). Some of the difference may be taste: the work in this paper touches on relevant and interesting problems to me.

In my comments to the authors, I noted that while they pitched the paper as being useful across neuroimaging modalities, it mainly focused on fMRI - to the exclusion of EEG/MEG. This mattered less to my rating when I approached the work as "Theory" rather than as "General". This is important, as a deficit in empirical results to support the claims might have led me to score the paper lower (e.g. 4). On the other hand, I'm happy enough with the authors' addition of the EEG analysis during rebuttals to keep my score at 5.

I was entirely satisfied by the inclusion of the AIC selection procedure - I previously viewed its omission as an oversight and not a serious flaw.

I very much appreciate the authors' attempts to answer the question about guidance for high across-subject variability. On the one hand, the paper is framed in a way that would place this question out of scope. On the other hand, it's harder to know how to put the results from this paper to use without a more comprehensive answer to it. So, while I think the paper is consistent without doing more, the paper's lack of a stronger answer to this question does affect my sense of the its potential impact.

Finally, in my review I promised the authors that I would increase the confidence of my rating if they addressed my comments. They did. So, as I started with a confidence of 4, I raised it to 5 in acknowledgement of their efforts.

Formatting concerns

I did not notice any major formatting, anonymity, or submission-policy concerns.

2 comments
Authors · CommentOpenReview ↗

Response to Reviewer Dzjb (1/2)

We thank the reviewer for these constructive and practically-oriented comments, which have made the paper more actionable. We address each point below.

(1) Applicability to EEG and MEG

Our framework requires three assumptions, and it is worth separating which are modality-specific.

1. Linear mixing. The recording at unit ii is a linear combination of shared latent signals plus independent noise. For M/EEG this is the standard forward model, and it holds at the sensor level by construction, since sensors are linear projections of source activity.

2. Fast-decaying autocorrelation along the axis correlations are computed over. This is required for the estimators to converge to their closed-form, and it is the assumption most likely to differ between modalities. For an event-related M/EEG design the natural axis is stimuli rather than time, and successive stimuli are approximately exchangeable, so the assumption holds more comfortably than for continuous fMRI for example. For a continuous M/EEG paradigm the raw autocorrelation is strong and the effective TT is correspondingly smaller. In that case, it is important to check the decay of the autocorrelation empirically and to use a high-pass filter to remove slow drifts. This recommendation also applies to continuous fMRI.

3. Alignment across trials. The shared signal must be aligned across the units being compared. For within-subject repetitions this follows from the trial structure. For across-subject fMRI, alignment requires projecting to a common anatomical template, as can be done with standard preprocessing pipelines (e.g. fMRIPrep). For across-subject M/EEG at the sensor level, alignment additionally requires comparable sensor positions and head geometry, and source-space projection to a common template is preferable. More across-subject variability will lead to larger gaps between the true noise ceilings and the estimators, as predicted by their closed-form, but the across-subject theory stays valid.

We agree a non-fMRI demonstration is valuable and have added one: the THINGS-EEG2 dataset (80 within-subject repetitions per image). We have also added an fMRI dataset with within-subject repetitions (THINGS fMRI1, 12 repetitions per image), so as to directly compare the two modalities.

We ran all noise ceiling estimators on both datasets and compared them to the synthetic results of Figure 2. The results precisely match the predictions from the synthetic data and theory: NC^SHSB\widehat{NC}^{\text{SHSB}} and NC^SNR\widehat{NC}^{\text{SNR}} overlap and increase with nn, while NC^TTMC\widehat{NC}^{\text{TTMC}} and NC^LOOC\widehat{NC}^{\text{LOOC}} converge to the same value from above and below, respectively. The key difference between the two modalities is that the EEG estimators are uniformly lower than the fMRI ones despite its more numerous repetitions, as expected from EEG data which is known to have very low signal-to-noise ratio. They are therefore both well predicted by the theory and the synthetic data, but simply correspond to different model parameters: lower signal and / or higher noise in EEG. This confirms that the framework is applicable to M/EEG, and that the conclusions do not change across modalities.

(2) Guidance for high across-subject variability

Within-subject repetitions, where the design permits it, are preferable, since all estimators are biased downwards in the across-subject case and this bias is larger when between-subject variability is high. If one still has to work with across-subject data, we recommend the following:

  • Do not use TTMC. In that case, this estimator is neither a lower nor an upper bound on the true noise ceiling, consequently it is not informative and can be misleading.
  • Report noise ceiling estimates as lower bounds. All four remaining estimators are valid lower bounds on the true noise ceilings, they should be reported as such. Normalized brain scores should be treated as upper bounds on the true score and explicitely described that way.
  • Compute both LOOC and LOOP. The two estimators are lower bounds on the same quantity, and their ordering depends on the signal distribution, the number of units, and the number of repetitions. We recommend computing both and reporting their maximum. Additional mixtures of the two estimators are also possible: instead of predicting the held-out trial vi(ℓ)\mathbf{v}_i^{(\ell)} from all units of all other trials, one can restrict the pool of variables to (1) the same unit ii across all other trials {vi(ℓ′),ℓ′≠ℓ}\{\mathbf{v}_i^{(\ell')}, \ell' \neq \ell\}, or (2) the average of all units across all other trials {vˉj(−ℓ),∀j}\{\bar{\mathbf{v}}^{(-\ell)}_j,\forall j\}. Those two variants decrease the generalization error of LOOP, but also reduce the signal space that can be predicted. Best practice is to compute all four and report the maximum as the tightest lower bound we can provide.
Authors · CommentOpenReview ↗

Response to Reviewer Dzjb (2/2)

(3) Implementation of AIC-based selection

The full implementation is in the repository linked in our response to the AC. The procedure is as follows.

For each unit, the split-half correlation is measured over random subsets of trials of increasing size, n=2,4,…,Nn=2,4,…,N, drawing 100 distinct subsets per size and computing a single random split-half correlation per subset. We deliberately do not average over several splits within a subset: the number of distinct partitions grows steeply with nn (one at n=2n=2, thousands at n=16n=16), so averaging would reduce the variance of the high-nn points far more than the low-nn ones. Since our model comparison uses the Gaussian constant-variance form of AIC, introducing a strongly nn-dependent variance term would misspecify the likelihood. The stability of each unit's curve comes instead from the 100 subsets per size.

Two models are then compared: a saturating form a⋅n/(n+c)a\cdot n/(n+c), with aa constrained to [0,1][0,1], against a constant. The saturating form is the expected behaviour of a unit carrying shared signal. We use AICc (small sample correction), given the small number of points, and take ΔAIC=AICconstant−AICsaturating\Delta \mathrm{AIC} = \mathrm{AIC_{constant}} - \mathrm{AIC_{saturating}}.

Finite-sample uncertainty is handled by bootstrapping: the 100 subsets are resampled with replacement, the curve recomputed and both models refitted, repeated 50 times. This gives a distribution of ΔAIC\Delta \mathrm{AIC} per unit rather than a point estimate; a unit is retained when the mean of that distribution exceeds the threshold, and fits that fail to converge are assigned a negative value so that no unit is retained by default.

The threshold is the one parameter requiring a choice, and it is not comparable across datasets: ΔAIC\Delta \mathrm{AIC} reflects how much evidence the recording provides, which depends on nn and TT. We calibrated it per dataset on synthetic data matched to the recording, choosing the smallest threshold that retains no more than an acceptable fraction of units (5% in our case) whose true noise ceiling falls below a chosen level (0.05).

We verified that 100 subsets and 50 bootstraps are sufficient to give a stable selection by repeating the procedure five times on the same data and comparing the retained units. This led to a mean pairwise overlap of at least 0.880.88 between the retained sets across our settings, with the number of retained units varying by less than 2%2\% between repetitions. The units that do change are those whose ΔAIC\Delta \mathrm{AIC} falls close to the threshold, and increasing the number of subsets and bootstraps further brings only marginal gains.

(4) Quantitative fit to the real data

We agree that the correspondence we report between the model and the recordings is only qualitative. Our claim is that the model reproduces the shape of the estimators' trajectories as a function of nn, their relative ordering, and the distances between them, which is what our recommendations depend on, rather than that it reproduces the recordings quantitatively with great precision.

A full quantitative fit would require estimating the distribution of mixing weights from the data, which we currently have no principled way to recover from a finite set of recordings. If we could, the closed forms would give the noise ceiling of experimental datasets directly.


We thank the reviewer again for these valuable comments. We believe the added EEG analysis, the guidance for high across-subject variability, and the clarified implementation of the AIC selection procedure strengthen the paper's practical impact and usability. We would be grateful if the reviewer would take these additions into account in their final assessment, and we are happy to discuss any remaining points.

Reviewer dygqOpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
2/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This article investigates the accuracy of noise ceiling estimation in brain scores. It points out that existing literature often uses different noise ceiling estimation methods interchangeably, but these methods are applicable to different experimental scenarios. The authors propose a unified generative model and analyze several commonly used noise ceiling estimators. Analysis was conducted on both synthetic and real data.

As requested, I have revised my evaluation from a theory-focused evaluation to the general evaluation criterion. If the authors can provide convincing evidence of effectiveness in concrete application settings and demonstrate consistent improvements across a broader range of datasets, I would be willing to raise my score.

Strengths and weaknesses

Strengths:

  1. This article focuses on the accuracy of noise ceiling estimation in brain scores, a crucial but easily confused issue in the NeuroAI benchmark.

  2. The authors analyze common estimators such as SHSB, SNR, LOOC, and TTMC using a unified generative model, explaining why they exhibit biases under different experimental settings.

  3. The article distinguishes between within-subject and across-subject scenarios and provides specific recommendations.

Weaknesses:

  1. The empirical validation is relatively limited. The synthetic experiments are generated from the proposed model itself, while the real Sherlock fMRI dataset can not provide ground-truth noise ceilings.

  2. The proposed generative model is useful and mathematically tractable, but it relies on idealized assumptions.

  3. Broken citation around line 557.

  4. Although the checklist states that limitations are discussed, the main paper does not contain a dedicated Limitations section.

Questions
  1. Could you confirm whether the main conclusions hold on additional datasets, such as NSD?

  2. Since the synthetic data are generated from the same generative model used for the theoretical analysis, the simulations mainly validate the internal consistency of the derivations. Could the authors test the estimators under alternative fMRI generative models?

  3. The paper discusses low- versus high-variability brain regions and provides different recommendations depending on this distinction. Could the authors provide a practical diagnostic criterion for determining whether a new dataset or brain region falls into the high- or low-variability regime?

Limitations

yes

Final justification

This is a primarily theory-driven paper, and the initial submission lacked sufficient empirical evaluation. The rebuttal provided additional methodological details and experimental results. I therefore maintain my positive recommendation.

Formatting concerns

no

4 comments
Authors · CommentOpenReview ↗

Reponse to reviewer dygq (1/3)

Before addressing the questions and limitations, we would like to say a word about what type of validation is possible to perform here. Brain scores are reported as a fraction of the noise ceiling, so the accuracy of the ceiling is essential for scores to be interpretable and comparable across different datasets. The difficulty is that the noise ceiling is by essence not measurable: it depends on the separation between the reproducible and the non-reproducible part of a recording, which no dataset provides. Our findings can therefore not be entirely validated on recorded data, where only the trend and the ordering of the estimators can be checked, and any model of the data we use in their place will come with assumptions. What we can do is keep those assumptions as few as possible, assess how confident we are in each of them for real data, and analyze what changes when they break. Within these limits, our results do question the interpretation of published brain scores, since the estimators used to normalize them are biased, in a way that depends on the experimental setting. They also provide guidance to minimize that bias and know when it might be present. We agree that the validation in the paper is limited and should be extended, and this is what we do here. We add two datasets, and we test the estimators under mechanisms that break the assumptions of our generative model, including one in which the synthetic noise is replaced by real fMRI recordings. Each mechanism is designed so that the true noise ceiling remains exactly known, which is what makes the comparison possible.

Additional datasets

We agree that additional datasets are needed to validate the conclusions of the paper. The NSD dataset cannot be used for our purpose, because it contains only 3 repetitions per image, which is too few to observe the trend of the estimators as nn grows. We instead use the THINGS fMRI1 dataset, which provides the same type of data as NSD, namely within-subject repetitions of GLM betas, but with 12 repetitions for 100 images. We ran all noise ceiling estimators on this dataset and compared them to the synthetic results of Figure 2. They match the theoretical predictions: SHSB and SNR overlap and increase with nn, while TTMC and LOOC converge to the same value from above and below respectively.

We additionally include the THINGS EEG2 dataset, with 80 repetitions per image, to generalize the results beyond fMRI. The behaviour is qualitatively identical, with lower values for all estimators despite the larger number of repetitions, as expected from the low single-trial signal-to-noise ratio of EEG. Both additional datasets are therefore well predicted by the theory and the synthetic data, but simply correspond to different model parameters: lower signal and/or higher noise in EEG. The relative ranking and trends of the estimators are preserved, so our recommendations are unchanged across the two modalities.

Alternative fMRI generative models

We agree that it would be highly valuable to compare the estimators to the true noise ceiling using a realistic generative model of fMRI data. Many such models have been proposed, but none of them can be straightforwardly used to validate our results. Most are single subject by design and provide no model of across-subject variability (neuRosim, fmrisim, POSSUM, SNAKE). The ones that do model different subjects different generative structures (TVB, NetSim) provide ground truth at the ROI or connectivity level. However, computing the true noise ceiling requires the noise free part of the recorded signal vi∗\mathbf{v}_i^* for each voxel, i.e. the mixing of the stimulus driven underlying signals with their subject specific weights. The only simulator we are aware of that provides both features is SimTB, which is the fMRI model from which our synthetic model is inspired, and which is therefore contained in our theoretical framework and does not challenge the assumptions needed to derive the closed forms.

Instead of using an existing fMRI simulator, we identify the assumptions our derivations require and implement mechanisms that violate them in our synthetic data. Under those mechanisms the closed forms no longer hold, but vi∗\mathbf{v}_i^* remains exactly known, so the estimators can still be compared empirically against the true noise ceiling.

Assumptions required by the framework. (a) The response decomposes additively into a reproducible stimulus driven component and noise vi=vi∗+ηi\mathbf{v}_i = \mathbf{v}_i^* + \boldsymbol{\eta}_i. (b) That component is a linear mixture of underlying signals shared across trials vi∗=∑kw[i,k]ϕk\mathbf{v}_i^* = \sum_k w[i,k] \boldsymbol{\phi}_k, with trial specific weights w[i,k]w[i,k] that are constant within a trial. (c) The noise is uncorrelated with the signal and uncorrelated across trials. (d) The noise is ergodic and any autocorrelation decays fast enough. (e) The mixing weights are drawn i.i.d. across subjects.

Authors · CommentOpenReview ↗

Response to reviewer dygq (2/3)

We implemented three mechanisms that challenge a part of those assumptions, and discuss the ones we could not test at the end of this section.

  1. Heterogeneous HRF Instead of using the same HRF parameters for all subjects and voxels, we draw one HRF per subject and per voxel, giving vi∗=∑kw(ℓ)[i,k](ϕk∗hi(ℓ))\mathbf{v}_i^*=\sum_k w^{(\ell)}[i,k] (\boldsymbol{\phi}_k * h_i^{(\ell)}), where hi(ℓ)h_i^{(\ell)} is the HRF of voxel ii and trial ℓ\ell. Mixing is performed in the neural domain and the convolution applied afterwards. This violates (b): the signals entering the mixture are no longer shared across trials.
  2. Recorded noise Instead of using Gaussian noise, we replace it with real fMRI recordings. We use the Sherlock dataset from which we remove the stimulus-driven component by applying an independent time shift to each subject. That way, the true noise ceiling vi∗\mathbf{v}_i^* is not modified, but the noise is directly taken from real fMRI recordings. This challenges assumption (d) in the most realistic way possible, since the noise is exactly that of a real fMRI recording.
  3. Shared slow components We add slow oscillations and drift common to all trials simulating the low frequency fluctuations of the acquisition, such as scanner drift and thermal effects. This violates assumption (c) since the noise is no longer uncorrelated across trials. This is not already present in mechanism 2 because the independent time shift removes all noise that is correlated across trials.

We tested each mechanism both in the within-subject and across-subject regimes by plotting the true noise ceilings and estimators as a function of nn (similar to Figures 2 and 3).

Within subject results SHSB and SNR remain unbiased under 1., 2. and 3., and TTMC and LOOC still approach the true noise ceiling from above and below. Here, the HRF does not vary across repetitions, and the slow components and non decaying autocorrelation from the fMRI noise are successfully discarded by the high pass filter we apply when preprocessing the data. Adding oscillations above the filter cutoff creates an upward bias to SHSB and SNR, which we discuss below.

Across subject results Mechanisms 2. and 3. are still correctly handled by the preprocessing and do not change the results. Mechanism 1. modifies the results quantitatively: the magnitude of the downward bias of SHSB and SNR increases, and the TTMC and LOOC asymptote falls further below the true noise ceiling. This is caused by the fact that differences in the HRF across subjects increase the across subject variability, which was the origin of the downward bias discovered in the paper.

The conclusions of the paper are therefore unchanged under those mechanisms. SHSB and SNR are valid estimators of NCmean{NC}^{\text{mean}}, and TTMC and LOOC bound NCsingle{NC}^{\text{single}} in the within subject regime. SHSB, SNR and LOOC are biased downwards in the across subject regime, and TTMC is no longer an upper bound on the true noise ceiling. The magnitude of the bias grows with across subject variability, to which heterogeneous HRFs contribute.

Remaining assumptions (a) Not having additivity modifies the definition of the noise ceiling: the noise ceiling is then generalized as the conditional expectation of the response given the stimulus and the trial's reproducible parameters (e.g. subject-specific weights). The noise component is then the difference between the response and that conditional expectation, which is zero-mean and uncorrelated with the conditional expectation by definition. Its variance becomes signal dependent, but our derivations only use the fact that the noise is zero-mean and uncorrelated with the signal and across trials, which are first-moment conditions, which a dependence of the noise variance on the signal does not break. The closed forms of the estimators are therefore unchanged.

Authors · CommentOpenReview ↗

Response to reviewer dygq (3/3)

(b) is the assumption our closed forms genuinely need, and it is a condition on the underlying signals at the neural level rather than on the recorded BOLD signals. Neither breaking (a) nor letting the HRF vary (mechanism 1) breaks the linearity at the neural level, they only break it in the BOLD space, which is why our conclusions survive both. Linear mixing of the underlying signals is a standard assumption of the field, made e.g. in shared response modelling, and it is supported by the fact that a recording unit integrates the activity of the populations it contains in a linear way.

(c) Noise shared across trials at frequencies above the filter cutoff would bias the estimators upward. We note however that those components are realistically not driven by the acquisition (which would be low frequency) but by the stimulus (e.g. subjects' heartbeat, breathing, or motion that is reliably modified by the stimulus). Therefore it is arguable whether they should be counted as signal, as a perfect model of fMRI responses to a stimulus would predict them.

(e) We draw the weights i.i.d. across subjects for concreteness, but the closed forms do not require it. Without this assumption they still hold provided Eℓ[w[i,k]]2E^\ell[w[i,k]]^2 is replaced by Eℓ≠ℓ′[w[i,k](ℓ)w[i,k](ℓ′)]E_{\ell \neq \ell'}[w[i,k]^{(\ell)} w[i,k]^{(\ell')}] and Varℓ[w[i,k]]\mathrm{Var}^\ell[w[i,k]] by 12Eℓ≠ℓ′[(w[i,k](ℓ)−w[i,k](ℓ′))2]\frac{1}{2}E_{\ell \neq \ell'}[(w[i,k]^{(\ell)} - w[i,k]^{(\ell')})^2]. The bias is therefore determined by the dispersion of the weights across subjects rather than by their variance around a common mean. Subgroups of subjects or region structure change the magnitude of the bias but never its direction.

Low vs high variability brain regions

There is no definitive diagnostic based on the estimators alone that separates the two regimes, because a region with high across-subject variability and a region with weaker shared signal produce similar estimator values. A useful suspicion is however provided by estimators that are much lower than the response properties of the region would lead one to expect. In the Sherlock dataset, for instance, the shared response of IT to a naturalistic film is not expected to be as much weaker than that of V1 as the estimators suggest, which points to across-subject variability rather than to an absence of shared signal.

The main criterion should however come from prior knowledge about the region and the alignment procedure. Early sensory areas such as V1 and A1 are well aligned by standard anatomical registration, whereas higher order cortical and subcortical regions have more variable functional topography and are known to be poorly aligned in a common space. This is consistent with the two groups we observe in Figure 4.

In the absence of such information, the conservative choice is to treat the across-subject estimates as lower bounds, and the looseness of the bounds increases with the variability we might suspect.

Limitations section

We agree that limitations should be discussed more explicitly in the paper. We included a more detailed discussion of the limitations of our work in our response to the AC, which we will include in the paper as a limitations section.

Broken citation

We apologize for the broken citation in the original submission. The reference for Bartlett's formula is: M. S. Bartlett, “On the Theoretical Specification and Sampling Properties of Autocorrelated Time-Series,” Supplement to the Journal of the Royal Statistical Society, vol. 8, no. 1, pp. 27–41, 1946, publisher: [Oxford University Press, Royal Statistical Society].

This will be fixed in the final version of the paper.


To summarize, we added two datasets to the empirical validation, extending it to GLM betas and to EEG, we ran further simulations challenging the assumptions of our model and discussed those we could not test, and we added the limitations section. The conclusions of the paper are unchanged, and the recommendations are directly usable on existing benchmarks.

We thank the reviewer for their careful reading and for the constructive questions, which led us to run additional experiments that we believe improved the paper. We hope these clarifications and additional experiments address the reviewer's concerns, and that they would consider raising their score accordingly. We remain available for any further question.

Reviewer dygq · CommentOpenReview ↗

The rebuttal addressed my concerns. I have therefore revised my rating to a positive recommendation and slightly increased my confidence.

Reviewer fVZKOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
4/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This theory paper analyzes the statistical accuracy of noise-ceiling estimators used in NeuroAI brain-score benchmarking. A single generative model of neural recordings (response = sum of stimulus-driven latents × mixing weights + noise) is used to derive closed-form properties of the common estimators (SHSB, SNR, LOOC, TTMC, LOOP). One switch, whether the mixing weights vary across trials, cleanly separates the within-subject from the across-subject regime. The headline result is that, in the across-subject setting, TTMC ceases to be an upper bound on the single-trial ceiling, contrary to common belief. Validation is on synthetic fMRI and the Sherlock fMRI dataset.

Strengths and weaknesses

Strengths. The problem is real, timely, and under-served — the noise ceiling is widely used as a folk quantity. The generative model is a clean unifying device, making within-vs-across a parameter rather than a separate analysis. The headline TTMC result is non-trivial and actionable, and the signal-free-unit bias plus AIC-based unit selection is a useful, practically-motivated addition.

Weaknesses (updated after rebuttal). (1) Finite-sample bias is now characterised (O(1/T), degrading to O(1/T^{1/4}) where the max is non-differentiable) and validated on synthetic and Sherlock data — resolved. (2) The relationship between the SNR estimand and the correlation NC^mean is now stated, with the history (Schoppe 2016; Lage-Castellanos 2018; Allen 2022) and the separate finite-T bias for the square-rooted form — resolved. (3) Within-subject real-data validation added (THINGS fMRI1, 12 repetitions; THINGS-EEG2, 80 repetitions), covering both the missing regime and a second modality — resolved; the same-model origin of the synthetic validation remains a residual concern, and real-data agreement is qualitative rather than quantitatively fitted. (4) LOOP is now characterised asymptotically and evaluated empirically, and the AIC procedure is benchmarked via retention curves against known ground truth — resolved. Code was available as supplementary material at submission; my original review was mistaken on this point.

Questions
  1. Quantify finite-sample bias (delta-method expansion, or empirical E[NC]−NC vs. T) for at least SHSB and TTMC. A finite-T characterization would move Quality 2→3.
  2. State and prove exact conditions under which the SNR estimand equals the correlation NC^mean, separately from the noise-homogeneity bias.
  3. Add at least one within-subject repeated-trial real dataset (e.g., NSD) to validate SHSB/SNR. This would raise Significance 3→4.
  4. Bring LOOP into the framework (at least an asymptotic bias statement) or include it empirically; benchmark the AIC selection (FP/FN vs. ground truth) and provide the code link claimed in the checklist.
Limitations

Key assumptions are flagged in-text, but there is no dedicated Limitations section, and three material limitations are not surfaced: the absence of within-subject real-data validation, the asymptotic (not finite-sample) nature of the "unbiasedness," and the same-model origin of the synthetic validation.

Final justification

My original review named two conditions and the authors met both.

I asked for a finite-sample characterisation of the bias, stating it would move Quality from 2 to 3. The rebuttal derives the O(1/T) rate for the estimators that reduce to a Pearson correlation, identifies the regime near zero noise ceiling where the max is non-differentiable and the rate degrades to O(1/T^{1/4}), and validates the exponents on synthetic data and on Sherlock. The persuasive element is not the slope fits but the successful out-of-sample prediction that the fitted exponent should lie closer to -1/4 in IT than in V1, which follows from IT's lower noise ceiling and is borne out (SHSB V1 -0.81 vs IT -0.13; SNR V1 -1.08 vs IT -0.53).

I asked for at least one within-subject repeated-trial real dataset, stating it would move Significance from 3 to 4, because the paper's most consequential recommendation was never tested in the regime where it applies. The authors correctly explain why NSD is unsuitable (three repetitions cannot show a trend in n) and instead add THINGS fMRI1 (12 repetitions, GLM-derived, hence also a different data type) and THINGS-EEG2 (80 repetitions, a second modality). The observed behaviour matches the theory: SHSB and SNR overlap and rise with n while TTMC and LOOC converge to the same value from above and below.

Beyond my two conditions, LOOP is brought into the framework with a projection characterisation and the bound LOOP ≤ NC_single, together with the practical rule to compute LOOC and LOOP (and the two restricted variants offered to Reviewer Dzjb) and report the maximum as the tightest available lower bound; the AIC procedure is benchmarked against known ground truth using retention curves rather than FP/FN rates, which is the right choice given that no voxel truly has zero signal, with concrete per-dataset thresholds and a stability check; a Limitations section is added; and code and data are released. The code was in fact uploaded as supplementary material at submission and I was wrong to list it as missing.

Two reservations remain, and they are why this is a 4 rather than a 5. The synthetic validation is still generated from the model used to derive the predictions — Reviewer dygq's objection — and the two new real datasets mitigate but do not eliminate the circularity. Agreement with real data remains qualitative: the shape, ordering and spacing of the estimator trajectories, with no quantitative goodness-of-fit, because the mixing-weight distribution cannot be recovered from finite recordings. The authors state this limitation plainly and I think that is the correct posture.

This is an under-served and genuinely useful methodological contribution: the noise ceiling is used as a folk quantity throughout NeuroAI benchmarking, and the result that TTMC is not an upper bound in the across-subject setting is both non-trivial and immediately actionable. I would encourage the authors to collect their now-scattered recommendations into a single decision table in the camera-ready.

Raising Rating from 3 to 4; Quality 2 → 3; Significance 3 → 4. Contribution Type corrected from "Theory" to "General" per the Program Chairs' request, with the effect on my assessment explained separately to the AC.

Formatting concerns

None

5 comments
Authors · CommentOpenReview ↗

Response to Reviewer fVZK (1/3)

We thank the reviewer for their careful reading and constructive comments. We address each point below, and have added new theoretical and empirical results in response. We are grateful for the reviewer's suggestions, which we believe have substantially strengthened the paper.

(1) Finite-sample bias

NC^SH\widehat{NC}^{\text{SH}}, NC^LOOC\widehat{NC}^{\text{LOOC}}, NC^TTMC\widehat{NC}^{\text{TTMC}}, NCsingle{NC}^{\text{single}} and NCmean{NC}^{\text{mean}} all share the same form: a Pearson correlation between two arguments, each a single trial vi(ℓ)\mathbf{v}_i^{(\ell)}, its noise-free component vi(ℓ)∗{\mathbf{v}_i^{(\ell)}}^*, or the mean of these quantities over a subset of trials. The expected value of the Pearson correlation converges to the population correlation at rate O(1/T)\mathcal{O}(1/T). However, the convergence requires fast decaying autocorrelations of the signals, which is often challenged in fMRI data because of drift and undamped oscillations. This assumption must therefore be empirically verified before computing noise ceiling estimators. Long-range autocorrelations can be mitigated by high-pass filtering the data.

NC^SHSB\widehat{NC}^{\text{SHSB}} and NC^SNR\widehat{NC}^{\text{SNR}} require an additional second-order Taylor expansion, which also results in a bias term of order O(1/T)\mathcal{O}(1/T). Because the max function is not differentiable at zero, the expansion is valid only when the distribution of the argument of the max function is strictly positive. As the noise ceiling approaches zero, this distribution is no longer strictly positive, and the Taylor expansion is no longer valid. The leading order term of the bias is then O(1/T1/4)\mathcal{O}(1/T^{1/4}), as it was shown in Appendix B.2 and B.3.

We validated the 1/T1/T convergence of the finite-sample bias on the synthetic data using a log-log plot of the bias as a function of T∈[101,103]T\in[10^1, 10^3] for all estimators and true noise ceilings. Using a linear fit, 5 estimators yield a slope whose confidence interval includes −1-1. The three remaining quantities have a slope between −1-1 and −1.2-1.2, which can be due to interference from the higher order terms.

Additionally, we checked the convergence rate in the Sherlock fMRI dataset (V1 and IT) by plotting each estimator as a function of TT and fitting A+B⋅TpA + B\cdot T^p to the data. The confidence intervals of the fitted exponent pp contained −1-1 for all estimators, except for NC^SNR\widehat{NC}^{\text{SNR}} and NC^SHSB\widehat{NC}^{\text{SHSB}}. For these two estimators, the power is of higher order (SHSB [V1: −0.81-0.81, IT: −0.13-0.13] and SNR [V1: −1.08-1.08, IT: −0.53-0.53]) and approaches −1-1 when only including voxels with high noise ceilings. This is consistent with having a mix of voxels with 1/T1/T and 1/T1/41/T^{1/4} convergence rates. This interpretation also predicts the pattern we observe: the fitted exponent is closer to −1/4−1/4 in IT than in V1 for both estimators, as expected from IT's lower noise ceiling and correspondingly larger fraction of voxels in the non-differentiable regime.

(2) Explained variance ratio vs correlation noise ceiling

The SNR estimator was first introduced by Schoppe et al. (2016) as an alternative to SHSB to estimate the correlation noise ceiling. It was then independently derived by Lage-Castellanos et al. (2018), which presented NC^SNR\widehat{NC}^{\text{SNR}} as estimating the correlation noise ceiling, and NC^SNR2{\widehat{NC}^{\text{SNR}}}^2 as estimating the explained variance noise ceiling. It was finally popularized by Allen et al. (2022) as a measure of explained variance. It is therefore commonly used for both correlation and explained variance noise ceilings, and its convergence properties to each of them are of interest.

In the T→∞T\to\infty limit, within-subject repetitions setting, and assuming no noise homogeneity bias, SNR is an unbiased estimator of both the correlation and explained variance noise ceilings (removing the square root in the latter case). For finite TT, they are both biased as O(1/T)\mathcal{O}(1/T), but the bias is smaller for the explained variance noise ceiling as it does not suffer from the additional bias brought by the square root.

Authors · CommentOpenReview ↗

Response to Reviewer fVZK (2/3)

(3) Dataset with within-subject repetitions

We agree that a validation of the within-subject repetition case using a second fMRI dataset is needed. However, the NSD dataset is not suitable for our purpose because it contains only 3 repetitions per image, therefore we cannot observe the estimators' trend as nn grows. Instead, to meet the same requirement, we chose the THINGS fMRI1 dataset, which contains 12 repetitions per image for 100 images and is also standard in the field. This new dataset also generalizes our results to a different type of data, as it is obtained using a GLM instead of being raw fMRI signals. We ran all noise ceiling estimators on this dataset and compared them to the synthetic results of Figure 2. The results precisely match the predictions from the synthetic data and theory: NC^SHSB\widehat{NC}^{\text{SHSB}} and NC^SNR\widehat{NC}^{\text{SNR}} overlap and increase with nn, while NC^TTMC\widehat{NC}^{\text{TTMC}} and NC^LOOC\widehat{NC}^{\text{LOOC}} converge to the same value from above and below, respectively.

Additionally, we included an EEG dataset (THINGS EEG2) with within-subject repetitionsto validate the results beyond fMRI. This dataset contains 80 repetitions per image. The results are qualitatively similar to THINGS fMRI1 but with much lower values for all estimators despite the numerous repetitions, as expected from EEG data which is known to have very low signal-to-noise ratio. The recommendations do not change between fMRI and EEG data, as this dataset confirms that the relative ranking and trends of the estimators are preserved in EEG data.

(4) LOOP, AIC, and code

LOOP estimator

Let vi(ℓ)\\{\mathbf{v}_i^{(\ell)}\\} be a set of recordings from different subjects ℓ∈1,..,n\ell\in\\{1,..,n\\} and channels i∈1,...,mi\in\\{1,...,m\\}. We define χ(−ℓ):=spanvi(ℓ′):ℓ′≠ℓ, ∀i\chi^{(-\ell)}:=\mathrm{span}\\{\mathbf{v}_i^{(\ell')}: \ell'\neq\ell,\,\forall i\\}. Note that the signals ϕk\boldsymbol{\phi}_k that are part of vi(ℓ′)=∑kw(ℓ′)[i,k],ϕk+ηi(ℓ′)\mathbf{v}_i^{(\ell')}=\sum_k w^{(\ell')}[i,k]\\,\boldsymbol{\phi}_k + \boldsymbol{\eta}_i^{(\ell')} are not necessarily contained in χ(−ℓ)\chi^{(-\ell)}. In particular, in the case where K>m(n−1)K>m(n-1) the linear transformation W(−ℓ)\mathbf{W}^{(-\ell)} is not invertible and ϕk∉χ(−ℓ)\boldsymbol{\phi}_k\notin\chi^{(-\ell)}.

In the limit T→∞T\to\infty, the prediction v^i(ℓ)\widehat{\mathbf{v}}_i^{(\ell)} is given by P(−ℓ)vi(ℓ)P^{(-\ell)}\mathbf{v}_i^{(\ell)}, with P(−ℓ)P^{(-\ell)} the orthogonal projection onto χ(−ℓ)\chi^{(-\ell)}. One can then show that the LOOP estimator is equal to

NC^iLOOP=Corrt(P(−ℓ)vi(ℓ),vi(ℓ))=∥P(−ℓ)vi(ℓ)∗∥∥vi(ℓ)∗∥,NCisingle≤NCisingle\widehat{NC}_i^{\text{LOOP}}=\mathrm{Corr}_t\left(P^{(-\ell)}\mathbf{v}_i^{(\ell)}, \mathbf{v}_i^{(\ell)}\right)=\frac{\|P^{(-\ell)}{\mathbf{v}_i^{(\ell)}}^\ast\|}{\|{\mathbf{v}_i^{(\ell)}}^\ast\|} \\, {NC}^{\mathrm{single}}_i \leq {NC}^{\mathrm{single}}_i

As a consequence, whether the LOOP estimator converges to the true noise ceiling as n→∞, nT→0n\to\infty, \, \frac{n}{T}\to 0 depends fully on the distribution of the weights w(ℓ)[i,k]w^{(\ell)}[i,k].

At finite TT, the above equation has an additional bias term of order O(1/T)\mathcal{O}(1/T) and, most importantly, a generalization error reduces LOOP further as OLS cannot find the optimal projection. The generalization error is mitigated, but not eliminated, by using ridge regression instead of OLS.

Whether LOOP performs better than LOOC depends on the trade-off between (1) how much larger the angle between χ(−ℓ)\chi^{(-\ell)} and vi(ℓ)∗{\mathbf{v}_i^{(\ell)}}^\ast is than the angle between vˉi(−ℓ)\bar{\mathbf{v}}_i^{(-\ell)} and vi(ℓ)∗{\mathbf{v}_i^{(\ell)}}^\ast, and (2) how large is the decrease caused by the generalization error. As they both are lower bounds of the true single-trial noise ceiling, we recommend computing both and reporting the maximum of the two.

We added LOOP to the synthetic data and the Sherlock fMRI dataset results, empirically. LOOP is significantly higher than LOOC in all analyzed brain regions, except for the amygdala where they are similar.

Authors · CommentOpenReview ↗

Response to Reviewer fVZK (3/3)

AIC voxel selection

We evaluated the procedure on synthetic data where the true per-voxel noise ceiling is known, in two regimes matching THINGS fMRI1 (n=12n=12 repetitions, T=100T=100 stimuli) and Sherlock (n=16n=16 subjects, T=2000T=2000 time points), pooling several noise levels so that the true noise ceiling spans a large range, and sweeping the AIC threshold over {0,2,4,6,8,10}\{0,2,4,6,8,10\}. Rather than false positive and false negative rates against a binary ground truth, we report the retention curve: the probability that a voxel is retained as a function of its true noise ceiling. FP/FN rates require labelling each voxel as carrying signal or not, but in practice it is unlikely that a voxel has exactly zero signal. What we are trying to prevent is that voxels with very low signal contribute with spurious large scores Si/NCiS_i/NC_i that are the ratio of two very small noisy quantities.

The retention curves reveal that, to retain no more than 5% of voxels with a true noise ceiling below 0.05, the AIC threshold should be set to 2 for THINGS fMRI1 and to 6 for Sherlock. At these thresholds, the retention probability is 50% at a true noise ceiling of 0.45 for THINGS fMRI1 and of 0.25 for Sherlock. The longer recording therefore enables the retention of voxels with roughly half as much signal. This is explained by the fact than at low TT, the additional variance of SH makes it more difficult to distinguish between pure noise and low to moderate signal.

Code availability

The code was uploaded at the time of submission as supplementary material and can be downloaded directly on OpenReview. Additionally, the repository containing all up-to-date code needed to reproduce the results has now been made available online, and the link was shared in the response to the AC. We will also include a link to the code repository in the final version of the paper.

(5) Limitations section

We agree that limitations should be discussed more explicitly in the paper. Here is a more detailed discussion of the limitations of our work, which we will include in the paper as a limitations section:

While our framework provides a unified theoretical grounding for noise ceiling estimation, several theoretical and empirical limitations remain. Theoretically, our model assumes linear mixing between shared latent signals and recording units. While well-motivated for fMRI hemodynamic responses and electroencephalography (EEG) linear sensor projections, this linearity assumption may break down in strongly non-linear measurement regimes. Furthermore, our derivations focus exclusively on encoding models and do not extend to Representational Similarity Analysis (RSA), for which the noise ceiling is defined differently and therefore the estimators' biases and convergence properties differ. Additionally, although we provide initial theoretical analysis for Leave-One-Out Prediction (LOOP), a complete theoretical treatment remains open: we currently lack a closed-form expression for its generalization error and a characterization of the convergence of the target signal to the span of the other subjects' signals based on the distribution of the mixing weights.

Empirically, our evaluation is restricted to fMRI and EEG modalities, leaving invasive electrophysiology (such as single-unit or multi-unit spiking activity) and magnetoencephalography (MEG) unexamined. Our empirical evaluation is further limited to visual (THINGS fMRI and THINGS EEG) and audiovisual stimulus paradigms (Sherlock fMRI), without validating performance in other cognitive domains such as natural language processing or motor control. Finally, our empirical validation relies on consistency checks of the closed-form expressions using synthetic data generated under a particular case of our theoretical framework, and qualitative comparisons across three datasets, rather than an exhaustive quantitative benchmark across diverse experimental and synthetic setups.


The reviewer indicated that a finite-TT characterization would move Quality from 2 to 3, and that a within-subject repeated-trial dataset would move Significance from 3 to 4. We have provided both: the finite-sample bias is now characterized analytically and validated on synthetic data and on the Sherlock dataset, and we have added two within-subject repeated-trial datasets, THINGS fMRI1 and THINGS-EEG2. We have also brought LOOP into the framework with an asymptotic result and empirical validation, benchmarked the AIC selection against ground truth, added the Limitations section, and made the code available. We therefore hope the reviewer will consider raising their scores accordingly, and we are happy to answer any further questions during the remaining discussion period.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…