FlowTrack: Controlling Edit-Signal Execution in Inversion-Free Flow Video Editing
Zhong JieLun, 王迪, Jisheng Dang, Bimei Wang, Jingwen Zhao, Wencan Zhang, Hong peng, Bin Hu, Leigang Qu
NeurIPS 2026
TL;DR. FlowTrack improves inversion-free flow video editing by controlling how online velocity-difference edit signals are executed, preserving source motion and structure while maintaining target alignment.
Abstract. Text-guided video editing requires applying a semantic change while keeping source motion, layout, and unchanged content stable. Recent inversion-free flow editors derive effective edit signals from target-source velocity differences, yet typically inject these signals directly at each solver step. Although ideal linear paths give velocity differences an endpoint-displacement interpretation, actual neural sampling trajectories need not be straight, and the observed difference evolves with the rollout. As the target branch evolves under previous injections, direct injection may accumulate temporal fluctuations and off-target perturbations, producing motion drift, identity flicker, or unintended changes in weak-response regions. We propose FlowTrack, a causal execution controller for inversion-free flow video editing. FlowTrack leaves the pretrained generator and raw edit signal unchanged, but executes the signal through a carried displacement-like direction and response-aware attenuation. We derive this update as the closed-form solution of a local execution objective that balances current signal tracking, temporal carrying, and weak-response suppression. On the full FiVE-Bench protocol, FlowTrack improves motion fidelity, unedited-region fidelity, and structure consistency over strong training-free diffusion- and flow-based editors while maintaining competitive target-prompt alignment.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:45 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
(a) FlowTrack separates construction of an edit signal from its online execution in inversion-free flow video editing. It uses a causal carrying term and a response-aware Otsu mask to preserve persistent edit direction while reducing injection in weakly responding regions, improving several temporal and structure-preservation metrics without retraining the generator. (b) The framing is insightful, the method is modular and training-free, and the reported gains are supported by ablations and statistical analysis. (c) The main concern is whether some preservation gain comes from simply weakening the edit, since CLIP alignment drops in places. The novelty may also be overstated relative to EMA plus masking, the carrying term contributes less than the mask, one sensitivity table appears numerically inconsistent, and runtime overhead is missing. (d) I would like region-separated edit/non-edit metrics, reconciliation of the table discrepancy, and the independent gain and cost of the two components. Unless these checks reveal systematic under-editing, the remaining concerns are primarily clarifications.
Final assessment. I have read the authors' response and reviewer follow-up. Region-separated metrics show that the preservation gains do not come from weaker edits, while the response also resolves the sensitivity-table discrepancy and reports compute and component contributions. All three reviewers support acceptance. The support mechanism drives most of the gain and the paper should say so more clearly, but this is an exposition issue rather than a technical flaw. My recommendation is Accept.
Final justification
The metareview above has been updated to include the final assessment after considering the author response and reviewer discussion.
Read meta-review
Meta-review
(a) FlowTrack separates construction of an edit signal from its online execution in inversion-free flow video editing. It uses a causal carrying term and a response-aware Otsu mask to preserve persistent edit direction while reducing injection in weakly responding regions, improving several temporal and structure-preservation metrics without retraining the generator. (b) The framing is insightful, the method is modular and training-free, and the reported gains are supported by ablations and statistical analysis. (c) The main concern is whether some preservation gain comes from simply weakening the edit, since CLIP alignment drops in places. The novelty may also be overstated relative to EMA plus masking, the carrying term contributes less than the mask, one sensitivity table appears numerically inconsistent, and runtime overhead is missing. (d) I would like region-separated edit/non-edit metrics, reconciliation of the table discrepancy, and the independent gain and cost of the two components. Unless these checks reveal systematic under-editing, the remaining concerns are primarily clarifications.
Final assessment. I have read the authors' response and reviewer follow-up. Region-separated metrics show that the preservation gains do not come from weaker edits, while the response also resolves the sensitivity-table discrepancy and reports compute and component contributions. All three reviewers support acceptance. The support mechanism drives most of the gain and the paper should say so more clearly, but this is an exposition issue rather than a technical flaw. My recommendation is Accept.
Final justification
The metareview above has been updated to include the final assessment after considering the author response and reviewer discussion.
1 comment
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposes FlowTrack, a training-free execution controller for inversion-free flow-based video editing. The core idea is simple: the velocity difference used is an online, evolving signal, not a fixed displacement command. The contribution is a better rule for executing that signal, leaving signal construction unchanged. FlowTrack replaces direct per-step injection with a causal EMA that carries a persistent edit direction and an Otsu-derived response-support mask that gates injection, and shows that these are the closed-form minimizers of a local objective. On FiVE-Bench, it reports gains in motion fidelity, preservation, and structure consistency over training-free baselines, with a small CLIP trade-off.
Strengths and weaknesses
Strengths:
-
The construction-execution decoupling is solid. The paper proves that direct execution fails to stay aligned with the target.
-
The main results are strong. The authors prove that their main performance gains are reliable by using statistical details in Table 4.
-
The manuscript is generally well-organized and easy to follow.
Weaknesses:
-
There is a major disconnect between the paper's theory and its actual results. The authors spend most of their time theorizing about the causal carrying term that barely improves video quality in Table 2, while giving little attention to the feature that actually drives almost all the performance gains.
-
The paper's claim of "better background preservation" might just be a side effect of making weaker edits overall. Because their masking technique restricts changes in background areas, the method actually struggles when it needs to add new objects in Table E.8.
-
No comparative compute reporting. The per-step Otsu estimation and causal carrying term add overhead is not quantified against the primary baselines.
Questions
-
Can you show the empirical justification for the carrying term beyond the latent diagnostics?
-
Can you provide edit-region-localized metrics to show the unedited-region gains in object addition?
-
What exact κ and ϵ were used in Eq. D.2 across all experiments, what smoothing kernel precedes the Otsu threshold, and how are degenerate thresholds handled? A κ sweep would help establish robustness.
-
Given that Table 3 shows CLIP decreasing and all stability metrics improving in λ, what motivates λ=0.2 over λ=0 or λ=0.4?
Limitations
yes
Final justification
The rebuttal resolves my primary concerns. Region-separated metrics confirm that FlowTrack’s preservation gains do not come at the expense of edit strength. Compute, sensitivity, and implementation details are now clear. While the disconnect between the theoretical emphasis on causal carrying and its minor empirical impact remains, this is an exposition issue rather than grounds for rejection. I have raised my score accordingly.
Formatting concerns
No
3 comments
Rebuttal
Thank you for identifying the concrete evidence needed to assess the two controller components. We address each question below.
1. Empirical value of causal carrying
Support and carrying address different execution errors: support determines where the signal is executed, while carrying controls its step-to-step directional consistency. Tables 2 and 4 establish carrying's independent contribution on the full benchmark. Relative to Support-only, adding carrying gives:
| Standard final-video metric | FlowTrack vs. Support-only: improvement [paired 95% CI] |
|---|---|
| MFS gain | +0.1078 [0.0289, 0.1914] |
| CLIP gain | -0.0286 [-0.0685, 0.0117] |
| PSNR gain | +0.1702 [0.1505, 0.1898] |
| LPIPS reduction | +0.6884 [0.5889, 0.8078] |
| MSE reduction | +0.6014 [0.5242, 0.6823] |
| SSIM gain | +0.1073 [0.0950, 0.1196] |
| Structure reduction | +0.2255 [0.1975, 0.2552] |
All six fidelity/structure gains are statistically significant, with 95% confidence intervals excluding zero. The CLIP change is not statistically significant because its interval includes zero.
To test the intended temporal effect directly, we additionally evaluated Direct, Causal-only, Support-only, and FlowTrack over the same 419 edits. Source-derived flow and forward-backward reliability masks were fixed across methods. We aggregated matched edits by source and computed paired 95% confidence intervals via source-cluster bootstrap. Causal-only versus Direct isolates carrying without support. FlowTrack versus Support-only isolates it under the same support configuration.
We report three complementary lower-is-better output-video temporal errors: aligned edge flicker measures contour instability after motion alignment, aligned SSIM dissimilarity measures motion-aligned structural inconsistency, and relative output/source-flow EPE measures output-motion deviation from the source. Positive reductions indicate improvement.
| Output-video temporal metric and interpretation | Causal-only vs. Direct: reduction [paired 95% CI] | FlowTrack vs. Support-only: reduction [paired 95% CI] |
|---|---|---|
| Aligned edge flicker (motion-aligned contour inconsistency) | 1.69% [1.47%, 1.95%] | 0.84% [0.66%, 1.04%] |
| Aligned SSIM dissimilarity (motion-aligned structural inconsistency) | 2.16% [1.82%, 2.56%] | 1.04% [0.79%, 1.35%] |
| Relative output/source-flow EPE (motion discrepancy) | 2.30% [1.60%, 2.97%] | 3.13% [2.46%, 3.82%] |
Thus, beyond the latent diagnostics, carrying produces statistically reliable gains on standard final-video metrics and consistent reductions in output-video contour, structural, and motion errors.
2. Object addition and region-separated evidence
We thank the reviewer for highlighting object addition, for which localized evidence is particularly informative. Table E.8 reports that FlowTrack achieves the highest global CLIP (27.1429). FiVE-Bench already computes PSNR/LPIPS/MSE/SSIM on the unedited region, so those columns match Table E.8. Using the same masks, we additionally computed CLIP-edit and MFS-edit within the edited region, with no method changes or retuning. Structure remains global:
| Method | CLIP-edit ↑ | MFS-edit ↑ | PSNR-unedit ↑ | LPIPS-unedit ↓ | MSE-unedit ↓ | SSIM-unedit ↑ | Structure-global ↓ |
|---|---|---|---|---|---|---|---|
| FateZero | 21.4245 | 75.0023 | 17.9453 | 236.6002 | 191.5811 | 61.5576 | 56.4715 |
| FLATTEN | 21.5312 | 80.5738 | 16.7304 | 268.6913 | 229.1915 | 58.1335 | 61.9898 |
| FlowDirector | 23.4297 | 94.1076 | 27.7151 | 52.7001 | 19.2845 | 85.9214 | 5.8687 |
| RAVE | 22.0107 | 91.5461 | 20.5534 | 175.1874 | 109.0435 | 68.9929 | 19.7474 |
| TokenFlow | 21.7602 | 90.8080 | 22.9799 | 167.4553 | 53.9430 | 69.2792 | 33.3354 |
| Wan-Edit | 22.6650 | 91.5966 | 24.8548 | 72.9187 | 40.1096 | 80.4392 | 10.2507 |
| DFVEdit | 23.4678 | 90.0657 | 24.4012 | 77.2411 | 42.6256 | 79.5563 | 12.5825 |
| FlowTrack | 23.4692 | 94.1143 | 27.9712 | 47.6488 | 19.8085 | 87.5497 | 5.3290 |
FlowTrack attains the highest CLIP-edit and MFS-edit, showing localized target alignment while preserving source-motion fidelity within the edited region. It simultaneously ranks first on PSNR-unedit, LPIPS-unedit, and SSIM-unedit, second on MSE-unedit, and first on global Structure. These results show that its object-addition preservation gains are not accompanied by lower localized CLIP alignment.
3. Exact support implementation
Except for the controlled sensitivity study below, all support-enabled benchmark experiments use one fixed setting without split- or example-specific tuning:
| Item | Exact implementation |
|---|---|
30 |
|
1e-12 |
|
| Pre-Otsu smoothing | 1x3x3 spatial average pooling with stride 1 and padding (0,1,1) |
| Degenerate response | If max-min <= 1e-12, bypass Otsu and set support to one everywhere |
Otsu recomputes at every solver step, while controls only the transition softness around this adaptive threshold. The small stabilizes when the threshold is near zero.
Using the same fixed sensitivity subset as Table 3 and holding all other settings fixed, we swept over a sixfold range:
| CLIP-edit ↑ | CLIP-global ↑ | MFS-edit ↑ | MFS-global ↑ | PSNR-unedit ↑ | LPIPS-unedit ↓ | MSE-unedit ↓ | SSIM-unedit ↑ | Structure-global ↓ | |
|---|---|---|---|---|---|---|---|---|---|
| 10 | 21.0472 | 27.5195 | 86.1345 | 89.1399 | 28.1540 | 46.5883 | 19.4837 | 88.2670 | 6.2344 |
| 20 | 21.0717 | 27.5715 | 85.9762 | 89.1812 | 28.0830 | 46.8173 | 19.8148 | 88.2241 | 6.3860 |
| 30 | 21.0669 | 27.5472 | 86.0500 | 89.1663 | 28.0725 | 46.9238 | 19.8819 | 88.2065 | 6.4311 |
| 40 | 21.0482 | 27.5430 | 86.0426 | 89.0034 | 28.0684 | 46.9150 | 19.8974 | 88.1993 | 6.4482 |
| 60 | 21.0769 | 27.5538 | 85.9959 | 89.0988 | 28.0675 | 46.9646 | 19.9079 | 88.1946 | 6.4579 |
Across all nine metrics, the relative standard deviation across settings is only 0.030%-1.288%. For the four edit-semantic and motion metrics, it is at most 0.072%. The conclusions therefore remain stable throughout the sixfold range, with serving as a fixed midrange default for transition softness.
4. Why ?
The row corresponds to Support-only, with carrying disabled. Table 3 displayed MSE/Structure using rather than the main table's scales. This affected only the displayed values, not the outputs, rankings, or trends. The table below uses consistent scales:
| MFS ↑ | CLIP ↑ | PSNR ↑ | LPIPS ↓ | MSE ↓ | SSIM ↑ | Structure ↓ | |
|---|---|---|---|---|---|---|---|
| 0 | 89.0420 | 27.6360 | 27.9142 | 47.8503 | 20.565 | 88.0821 | 6.708 |
| 0.05 | 89.0756 | 27.5780 | 27.9593 | 47.5330 | 20.394 | 88.1195 | 6.621 |
| 0.10 | 89.1514 | 27.5512 | 27.9998 | 47.2680 | 20.172 | 88.1477 | 6.535 |
| 0.20 | 89.1663 | 27.5472 | 28.0725 | 46.9238 | 19.882 | 88.2065 | 6.431 |
| 0.40 | 89.1671 | 27.5205 | 28.2119 | 46.3439 | 19.343 | 88.2917 | 6.207 |
Moving from to increases MFS/PSNR/SSIM by 0.1243/0.1583/0.1244 and reduces LPIPS/MSE/Structure by 0.9265/0.683/0.277, with a CLIP change of -0.0888. Moving from to gives only +0.0008 MFS while decreasing CLIP by another 0.0267, although preservation metrics continue improving. Thus, captures 99.4% of the MFS gain observed at while retaining higher CLIP. We selected it as the default operating point near MFS saturation, balancing carrying strength and target alignment.
5. Compute overhead
FlowTrack requires no additional model evaluations: it uses the same number of source/target velocity evaluations per solver step as Direct execution and adds only lightweight tensor operations. Since Direct omits both support and carrying while leaving the rest of the generation pipeline unchanged, it provides the minimum-cost matched reference for measuring their overhead.
All four variants were evaluated on the complete benchmark with identical hardware and generation settings:
| Execution | Mean time/video (s) ↓ | Relative time change vs. Direct | Mean peak GPU memory (MB) ↓ | Relative memory change vs. Direct |
|---|---|---|---|---|
| Direct execution | 496.452 | 0.0000% | 17,405.5 | 0.0000% |
| Causal-only | 496.624 | +0.0346% | 17,406.5 | +0.0057% |
| Support-only | 496.532 | +0.0161% | 17,405.6 | +0.0006% |
| FlowTrack | 496.737 | +0.0574% | 17,406.7 | +0.0069% |
FlowTrack adds only approximately 0.285 s/video, or 0.0574%. Its mean peak GPU memory is 17,406.7 MB, only 1.2 MB or 0.0069% above Direct execution. Together with the unchanged model-evaluation count, these results show that the generation-time and memory overhead of the complete controller is negligible.
Thank you for the thorough and well-organized rebuttal. You have resolved the majority of my concerns, and I have raised my rating accordingly to reflect this. The region-separated evaluation addresses my main worry regarding weaker edits (W2/Q2). Seeing the matched CLIP-edit inside the edited region (21.8909 vs. 21.8896 overall; 23.4692 vs. 23.4297 for object addition) alongside improved MFS-edit confirms that the background preservation gains do not come at the expense of edit strength. Furthermore, the compute report (W3), the sweep and support-implementation details (Q3), and the justification on the corrected scale (Q4) are all clear and convincing.
However, one concern remains only partially addressed: the disconnect between the theoretical emphasis on causal carrying and its actual empirical contribution (W1/Q1). While the new statistics confirm that causal carrying reliably contributes (paired CIs exclude zero across six metrics, plus the output-video temporal metrics), its absolute effect remains minor compared to the support mechanism. Specifically, carrying adds roughly +0.11 MFS over Support-only, whereas support adds ~+2.15 over Direct. The imbalance between how much time the paper spends theorizing about causal carrying versus its actual measured contribution persists, so I view this point as reframed rather than fully resolved.
To finalize my assessment and maintain my raised score, I ask the authors to confirm the following updates for the camera-ready version explicitly:
-
Move the region-separated evaluations: The CLIP-edit/MFS-edit tables and the output-video temporal metrics from the rebuttal must be moved into the main text. The under-editing question is too central for readers to hunt for in the appendix.
-
Rebalance the exposition: Adjust the text so the theoretical weight given to each component aligns with its empirical reality. Please explicitly state—now that the numbers clearly show it—that the support mechanism drives the vast majority of the performance gains, while causal carrying provides a smaller, albeit statistically reliable, temporal stabilization.
-
Qualitative evidence: Include at least one qualitative object-addition example demonstrating that the response-derived mask does not suppress genuinely additive edits.
-
Table 3 correction: Confirm that the corrected Table 3 (incorporating the display-scaling fix) will appear in the final manuscript.
Response to Reviewer P9UM
Thank you for taking the time to provide these detailed and constructive comments. Your comments help us clarify how the final manuscript can present the respective empirical roles of response-aware support and causal carrying more clearly, while making the key evidence on edit strength and temporal consistency easier for readers to assess. We also appreciate your concrete suggestions regarding qualitative object-addition evidence and the correction to Table 3. Accordingly, we will incorporate the following focused revisions into the camera-ready manuscript:
-
Main-text evaluation. We will include the region-separated CLIP-edit/MFS-edit tables from our rebuttal in the main experimental section. The output-video temporal metrics and their paired confidence intervals will also be presented there, allowing readers to assess the evidence on edit strength and temporal consistency directly from the main paper.
-
Component emphasis. We will refine the wording and emphasis in the relevant discussion to better reflect the empirical roles of the two components. The text will make clear that response-aware support is the primary source of the aggregate performance gains, while causal carrying provides a smaller but statistically reliable stabilization benefit beyond support alone, with consistent improvements in final-video fidelity and output-video temporal coherence.
-
Object-addition examples. We will add several representative qualitative object-addition examples showing the source frames, edited results, and corresponding response-derived support maps. These examples will show that newly added content receives sufficient support and is not suppressed during execution.
-
Table 3. We confirm that the final manuscript will include the corrected Table 3 with the display-scaling issue resolved.
We sincerely appreciate these concrete suggestions and will ensure that all four revisions are reflected in the final paper.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper introduces a training-free controller for flow-based video editing that modifies how velocity-difference signals are injected into the sampler. Rather than using direct per-step injection, it leverages temporal memory and response-aware attenuation to optimally suppress edits in weak-response regions. Evaluated on benchmark, FlowTrack improves motion fidelity and structural consistency over existing baselines with only a minimal trade-off in prompt alignment.
Strengths and weaknesses
Strengths
1- The motivation is strong and well-framed: by separating signal estimation from signal execution, the paper identifies the injection rule as a distinct, previously under-explored design axis in inversion-free flow editing, with the key insight being that a velocity difference is an online, state-dependent observation rather than a fixed endpoint-displacement command.
2- The method is attractive from an application standpoint: it is training-free and modifies only the injected edit-channel input, leaving the generator and raw signal untouched, which makes it cheap and in principle compatible with existing flow editors.
Weaknesses:
1- The MFS improvement over FlowDirector is marginal, and it is accompanied by a statistically significant drop in CLIP score (see Table 1). Because the CLIP score measures how well an edit is applied, the improvements in preservation metrics might simply result from the model applying weaker edits rather than higher-quality ones. I feel the current evaluation fails to disentangle these two possibilities.
2- The control-theoretic terminology oversells what is fundamentally a simple mechanism. When stripped of the Wiener-kernel, I feel the approach reduces to an exponential moving average over the edit direction combined with a thresholded mask. While the proofs are mathematically sound, I think it boils down to these 2 equations, which risks overstating the method's actual novelty.
3- The λ sensitivity results in Table 3 contradict the rest of the paper, in the sense that ranges of the numerical values are different, and i couldn't see any discussion in the paper regarding that tavle. It reports Structure scores around 0.64–0.67 and MSE around 2.0, whereas the main table and ablations report Structure at approximately 6 and MSE near 15 for the exact same method. I would appreciate it if you could clarify.
Questions
see weaknesses.
Limitations
yes
Final justification
I am maintaining my positive score as the rebuttal has addressed some of my concerns, and believe the work is valuable for the field.
Formatting concerns
no
3 comments
Rebuttal
Thank you for the careful assessment. We address the three concerns directly below.
1. Preservation gains and edit strength
The original Overall comparison shows a 0.1688 global-CLIP difference between FlowTrack and FlowDirector. However, a global score does not isolate whether this difference comes from reduced target response in the edited region. FiVE-Bench already computes PSNR/LPIPS/MSE/SSIM on the unedited region, so those columns match the original Overall table. We additionally computed MFS-edit and CLIP-edit within the edited region on the full benchmark using the same masks, without changing or retuning any method. Structure remains a global structural-deviation metric.
| Method | MFS-edit ↑ | CLIP-edit ↑ | PSNR-unedit ↑ | LPIPS-unedit ↓ | MSE-unedit ↓ | SSIM-unedit ↑ | Structure-global ↓ |
|---|---|---|---|---|---|---|---|
| FateZero | 68.7316 | 20.7924 | 18.6122 | 236.8776 | 155.9120 | 69.1964 | 55.3834 |
| FLATTEN | 68.5287 | 21.4840 | 16.3716 | 269.9812 | 255.4401 | 62.9804 | 71.3739 |
| FlowDirector | 83.1143 | 21.8896 | 27.4104 | 52.4975 | 22.9882 | 87.7195 | 8.9845 |
| RAVE | 80.8343 | 21.8726 | 20.8132 | 137.9647 | 96.9810 | 78.1291 | 25.2783 |
| TokenFlow | 79.7568 | 20.8532 | 23.0263 | 137.5256 | 57.7608 | 75.4634 | 26.6105 |
| Wan-Edit | 81.2604 | 20.7129 | 25.5700 | 71.1971 | 39.8569 | 83.4118 | 12.2960 |
| DFVEdit | 81.1092 | 21.5048 | 25.1480 | 72.4622 | 37.9288 | 82.9375 | 11.9711 |
| FlowTrack | 84.2349 | 21.8909 | 29.2961 | 39.5408 | 15.3677 | 90.2092 | 5.9808 |
The separated results distinguish edit effectiveness from source preservation. Within the edited region, FlowTrack achieves the best MFS-edit (84.2349, +1.1206 over FlowDirector) and essentially identical CLIP-edit (21.8909 versus 21.8896). Thus, its preservation gains are not accompanied by a weaker local target response. In the unedited region, FlowTrack simultaneously improves every preservation metric over FlowDirector: +1.8857 PSNR, -12.9567 LPIPS, -7.6205 MSE, and +2.4897 SSIM. It also reduces global Structure deviation by 3.0037.
2. Simplicity and novelty
We appreciate the reviewer's observation that the update admits a compact EMA-like factorization. This is a useful algebraic view of the closed form. The key distinction is that FlowTrack additionally specifies state and execution semantics that a generic “EMA plus a thresholded mask” does not determine. The raw difference is re-estimated at every solver step along a rollout already changed by prior injections. FlowTrack maps this online, state-dependent observation to the actual solver input through the unique optimizer of a strictly convex local objective. Its two-stage factorization is therefore an exact implementation of this optimizer, with both stages derived from the same objective rather than independently appended.
More specifically, the full formulation determines several consequential choices. First, memory carries the pre-attenuation direction , so temporary low support affects the current execution without recursively erasing the carried edit direction. Second, Otsu estimates the adaptive center of a continuous sigmoid support field rather than producing a binary execution mask. For positive support, this coefficient is exactly calibrated into the same objective's diagonal execution cost through . Third, Direct, Causal-only, and Support-only are exact reductions of the same execution law rather than separately designed heuristics.
Thus, the contribution is the construction/execution decomposition and a state-dependent causal law for converting an evolving target-source observation into a solver input. The compact closed form follows from solving that execution problem, and its optimization-derived state and execution semantics distinguish it from a generic EMA followed by masking.
3. Reported -sensitivity scale
Thank you for identifying this inconsistency. Our audit found a display-scaling error in Table 3. The underlying evaluator outputs are unchanged. The Overall and ablation tables report MSE and Structure after multiplication by and , respectively, whereas Table 3 accidentally used and . Both columns were therefore displayed 10 times too small. The corrected table is:
| MFS ↑ | CLIP ↑ | PSNR ↑ | LPIPS ↓ | MSE ↓ | SSIM ↑ | Structure ↓ | |
|---|---|---|---|---|---|---|---|
| 0 | 89.0420 | 27.6360 | 27.9142 | 47.8503 | 20.565 | 88.0821 | 6.708 |
| 0.05 | 89.0756 | 27.5780 | 27.9593 | 47.5330 | 20.394 | 88.1195 | 6.621 |
| 0.10 | 89.1514 | 27.5512 | 27.9998 | 47.2680 | 20.172 | 88.1477 | 6.535 |
| 0.20 | 89.1663 | 27.5472 | 28.0725 | 46.9238 | 19.882 | 88.2065 | 6.431 |
| 0.40 | 89.1671 | 27.5205 | 28.2119 | 46.3439 | 19.343 | 88.2917 | 6.207 |
After correction, MSE and Structure are reported on the same scale as in the Overall and ablation tables. They need not equal the Overall values because Table 3 uses the same fixed 100-example subset for every , whereas Table 1 aggregates all 419 examples.
The corrected results also make the intended trend explicit. Increasing strengthens temporal carrying: from to , MFS increases by 0.1251, PSNR by 0.2977, and SSIM by 0.2096, while LPIPS, MSE, and Structure decrease by 1.5064, 1.222, and 0.501, respectively. CLIP changes by only -0.1155, reflecting the expected preservation/alignment trade-off. We use as the default balanced operating point: it already captures 0.1243 of the total 0.1251 MFS improvement observed at , while retaining higher CLIP. The corrected scale therefore does not change any ordering, sensitivity trend, or conclusion. We will replace the table and add this discussion in the camera-ready version.
Thank you for the detailed and well-organized rebuttal. The region-separated evaluation (essentially identical CLIP-edit alongside improved MFS-edit) addresses my concern that the preservation gains might come from applying weaker edits, and the explanation of the Table 3 display-scaling issue resolves the numerical inconsistency I raised. I also appreciate the clarification distinguishing the objective-derived execution law from a generic EMA-plus-masking view. After considering the rebuttal and the other reviews, I will keep my scores unchanged.
Response to Reviewer u4mz
Thank you very much for taking the time to carefully consider our rebuttal in light of the other reviews. We sincerely appreciate your confirmation that the region-separated evaluation addresses the weaker-edit concern and that the Table 3 scaling explanation resolves the numerical inconsistency. We are also grateful for your thoughtful consideration of our clarification distinguishing the objective-derived execution law from a generic EMA-plus-masking interpretation. Your careful feedback has been very helpful in sharpening both our evaluation and presentation. Thank you again for your time and constructive assessment.
- Rating
- 5/6
- Confidence
- 2/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper introduces a causal execution controller designed to improve inversion-free flow video editing. The authors claim that directly injecting target-source velocity differences at each solver step ignores the state-dependent nature of these signals, leading to motion drift, identity flickering, and unintended changes in unedited regions. To address this, FlowTrack modifies how the edit signal is executed by employing a carried displacement-like direction and response-aware attenuation. Formulated as a closed-form solution of a local execution objective, this method balances signal tracking, temporal consistency, and weak-response suppression without requiring changes to the pretrained models.
Strengths and weaknesses
Strength
- Authors found that direct injection causes temporal fluctuations in inversion-free flow editing. Treating the velocity difference as an online, state-dependent variable rather than a fixed command is a logical and creative shift in perspective.
- The paper is theoretically well-founded, featuring a clear derivation of the closed-form solution and well-defined notation.
Weakness
- The effectiveness of the response-aware attenuation and temporal carrying might be challenged when the text prompt requires extreme topological or structural changes that inherently conflict with the source motion.
Questions
Q1. How does the proposed method behave when the text prompt demands extreme topological modifications?
Limitations
yes
Formatting concerns
N/A
3 comments
Rebuttal
Thank you for recognizing the construction/execution distinction and the theoretical formulation, and for raising this important question. The relevant factor is not the magnitude of a topological change alone, but whether the pretrained generator exposes a sufficiently strong and temporally consistent target-source velocity response for the new structure. FlowTrack controls this observed response. It neither fixes the source topology nor creates semantic evidence absent from the generator.
Effective case. Consider adding a second object in a previously empty region while the camera and the original object continue moving. If the target branch repeatedly produces a strong local response in that region, the support field assigns it greater execution weight even though no source object or fixed source mask exists there. Meanwhile, the carried direction is updated by successive responses, allowing the emerging object's edit direction to persist across solver steps while still adapting as its shape and motion develop. In this case, conflict with the source motion does not itself block the edit: FlowTrack can execute the new topology when its response is spatially identifiable and directionally consistent across steps.
Boundary case. Consider instead splitting one moving object into two parts that must follow different trajectories. If the generator alternates high-response locations or produces opposing directions across adjacent steps, support is recalculated from each step's response magnitude while carrying blends incompatible directions. Because support can pass or attenuate the carried direction but cannot amplify or invent a missing one, the result may be a partial split, delayed motion, or a more conservative edit. If a consistent response emerges later, both the carried direction and support update accordingly. If the ambiguity persists, FlowTrack cannot by itself resolve the requested topology.
Thus, FlowTrack is effective when a large structural change yields observable and temporally compatible edit evidence, and becomes less effective when that evidence remains weak, intermittent, or contradictory. Although FlowTrack imposes no hard source-topology constraint, its conservative execution may further attenuate weak evidence or smooth conflicting directions. Its boundary therefore depends on both the available target-source signal and whether that evidence remains compatible with support-aware causal execution. We will add this scenario-based analysis and a discussion of representative failure cases to the camera-ready to clarify FlowTrack's operating boundary under large structural changes.
Thank you for the detailed and thoughtful response. The scenario-based explanation distinguishing between the "effective case" and the "boundary case" perfectly addresses my question regarding how FlowTrack handles extreme topological modifications. My concern has been fully addressed. Thank you again for the clarification, and I maintain my rating of this solid work.
Response to Reviewer 9FRg
Thank you for your positive assessment and for confirming that our response fully addresses your concern. Your question helped us articulate the scope and limitations of FlowTrack more clearly. We sincerely appreciate your constructive feedback.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Response to the Meta-Review
Thank you for the clear and constructive metareview. We completed the requested checks. On the full benchmark, the region-separated evaluation shows essentially identical CLIP-edit for FlowTrack and FlowDirector (21.8909 vs. 21.8896), while FlowTrack improves MFS-edit and all unedited-region preservation metrics. This evidence does not indicate systematic under-editing.
The Table 3 discrepancy is a display-only scaling issue, not an experimental inconsistency. Its MSE and Structure columns used display factors 10 times smaller than those in the Overall and ablation tables. Correcting these factors simply rescales the reported values. The underlying outputs, rankings, trends, and conclusions remain unchanged.
The ablation results confirm complementary contributions from support and carrying. Adding carrying to Support-only improves all six fidelity and structure metrics, with paired 95% confidence intervals excluding zero and no statistically significant CLIP change. The added output-video measures also show reductions in aligned edge flicker, aligned structural dissimilarity, and relative flow EPE, demonstrating that carrying improves temporal consistency in the output videos. Relative to Direct, Causal-only and Support-only add 0.172 and 0.080 s/video, respectively. Complete FlowTrack adds 0.285 s/video and 1.2 MB mean peak GPU memory, with no additional velocity evaluations.
In the final manuscript, we will correct Table 3, include the additional results and component costs, and clarify that our contribution is the construction/execution decomposition and its objective-derived causal execution law, rather than EMA or masking alone.