GAPS: Gradient-Aware Adaptation-Gap Scoring for Time-Series Anomaly Detection with Foundation Models
Jongwon Kim, Byunghun Song, Young Myoung Ko
NeurIPS 2026
TL;DR. We reduce noise-induced false positives using the gap between zero-shot and fine-tuned TSFM outputs, with routing guided by sufficient conditions for the gap's effectiveness.
Abstract. Reconstruction error is the standard signal for unsupervised time-series anomaly detection and has been widely adopted by time-series foundation models (TSFMs). It is, however, vulnerable to input noise: the resulting score tracks the noise level itself rather than whether a sample is truly anomalous, and this failure is especially pronounced in domains where the noise envelope itself carries information about the underlying process state. We propose the adaptation gap , the difference between fine-tuned and zero-shot reconstruction losses, as a noise-robust complement. We prove that the noise inflating both losses cancels out of on average, and establish a calibration-anchored, population-level mean-separation guarantee. Building on these results we introduce GAPS (Gradient-Aware Adaptation-Gap Scoring), which selectively augments with under a calibration-only routing layer with no label-tuned hyperparameters. Across a synthetic suite, HRV and UCDDB benchmarks whose normal class is intrinsically noisier than the anomaly class, and TSB-AD-U with a predefined noise-stress condition, GAPS preserves performance under standard conditions and yields substantial gains under noise stress.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:47 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The reviewers find the core idea of leveraging the difference between zero-shot and fine-tuned reconstruction losses both interesting and elegant, with strong theoretical motivation and promising empirical results, particularly under noisy-normal conditions. The proposed GAPS framework effectively improves the robustness of Diff and demonstrates favorable performance over several foundation-model baselines. However, reviewers question the generality of the underlying assumptions, noting that the method appears tailored to scenarios where normal samples are noisier than anomalies. Additional concerns include limited comparisons with non-foundation baselines, unclear definitions of several key concepts, insufficient evaluation of alternative calibration methods and computational efficiency, and the need for stronger theoretical justification and broader validation on naturally noisy real-world datasets.
I am satisfied by authos responses.All Reviewer also given acceptance as their recomendation. Hence I am accepting the paper.
Final justification
I am satisfied by authos responses.All Reviewer also given acceptance as their recomendation. Hence I am accepting the paper.
Read meta-review
Meta-review
The reviewers find the core idea of leveraging the difference between zero-shot and fine-tuned reconstruction losses both interesting and elegant, with strong theoretical motivation and promising empirical results, particularly under noisy-normal conditions. The proposed GAPS framework effectively improves the robustness of Diff and demonstrates favorable performance over several foundation-model baselines. However, reviewers question the generality of the underlying assumptions, noting that the method appears tailored to scenarios where normal samples are noisier than anomalies. Additional concerns include limited comparisons with non-foundation baselines, unclear definitions of several key concepts, insufficient evaluation of alternative calibration methods and computational efficiency, and the need for stronger theoretical justification and broader validation on naturally noisy real-world datasets.
I am satisfied by authos responses.All Reviewer also given acceptance as their recomendation. Hence I am accepting the paper.
Final justification
I am satisfied by authos responses.All Reviewer also given acceptance as their recomendation. Hence I am accepting the paper.
- Rating
- 4/6
- Confidence
- 1/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
For anomaly detection in time series, the authors analyze the difference between foundation models with and without fine tuning. The authors propose GAPS (Gradient-Aware Adaptation-Gap Scoring) which combines the scores from the fine-tuned mode and the difference from the (zero-shot) foundation model.
The difference, Diff(x), between the loss from the fine-tuned model, L_FT(x), and the loss from the zero-shot (foundation) model, L_ZS(x), is the adaptation gap. Diff is expected to be from model bias, and not from input noise, based on Proposition 1 via bias-variance decomposition. Proposition 2 related Diff with sum of per-step "alignment values". They use a "hard gate" (boolean) at the dataset-level, while a routing weight at the sample level. The GAPS anomaly score is a linear combination of score from the fine-tuned model and Diff.
For empirical comparisons, they use the HRV data set and those in the TSB-AD-U benchmark. The proposed approach is compared with and 1 existing algorithm, the fine-tuned model, with 3 backbones. The proposed approach generally outperforms the others. Ablation studies indicate the contributions of the different components.
Strengths and weaknesses
S1. Analyzing the difference between the fine-tuned model and the zero-shot model is interesting.
S2. The empirical results indicate that the proposed approach compares favorably against fine-turning from foundation models.
W1. Some of the terms are not well defined, which significantly hinders clarity of the proposed concepts/ideas. See questions below.
W2. Only the fine-tuned detectors with 3 backbones were compared. Including a few models that do not involve foundation models would be interesting.
Questions
Sec 3.2: alignment values and alignment ratio are not discussed before they are used? "alignment ratio of Section 3.4"--Section 3.4 doesn't seem to discuss what alignment ratio is. The alignment values seem to be related to weight updates from the foundation model.
Sec 3.3: What is theta_1? Theta after one step from theta_0?
Sec 3.5: According to the introduction in Sec. 3, z is the output of the backbone (before a head) which is frozen. Not sure what z_F and Z_Diff are? Should z_F be L_FT and Z_Diff be Diff?
Limitations
Limitations of the proposed approach do not seem to be mentioned.
Final justification
The clarity issues can be addressed. Since the other reviewers find the basic idea interesting and my confidence is low, I increased my rating to "borderline accept".
Formatting concerns
None observed
5 comments
Q1. Alignment value and alignment ratio
Original reviewer question: "Sec 3.2: alignment values and alignment ratio are not discussed before they are used? "alignment ratio of Section 3.4"--Section 3.4 doesn't seem to discuss what alignment ratio is. The alignment values seem to be related to weight updates from the foundation model."
Alignment measures whether a sample follows the average normal update, while is the calibration-normalized quantity used for routing.
Thank you for pointing out the missing ordering and intuition. Only the lightweight head is updated. Normal-only fine-tuning defines , while is the sample gradient, and
At first order, means average-normal adaptation benefit, less benefit, and that the normal update increases the sample loss. The practical routing quantity is
Thus, the alignment value explains Diff along the theoretical trajectory, while is the calibration-normalized routing ratio.
Q2. Definition of
Original reviewer question: "Sec 3.3: What is theta_1? Theta after one step from theta_0?"
is the parameter obtained after one full-batch normal-gradient step from .
Your reading is exactly correct:
We will define it directly in Proposition 3.
Q3. Definition of and
Original reviewer question: "Sec 3.5: According to the introduction in Sec. 3, z is the output of the backbone (before a head) which is frozen. Not sure what z_F and Z_Diff are? Should z_F be L_FT and Z_Diff be Diff?"
This is a genuine notation collision on our side: is used both for the frozen backbone embedding and for the calibration-standardized scores. We will change the embedding symbol.
Your reading is correct in substance: and are calibration-standardized versions of and Diff, not backbone embeddings. For ,
In the revision the frozen backbone will be written so that is reserved for standardized scores, and both scores will be defined at first use.
Thanks for the comments.
Table 3: do you have results for Diff, in addition to S_F (S_FT) and S_GAPS?
Any insights on why Diff is preferred some times, while S_FT is preferred at other times?
- Rating
- 4/6
- Confidence
- 5/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This work addresses the central challenge of noise-sensitive reconstruction-error scoring in time-series anomaly detection with foundation models. The paper argues that the standard fine-tuned reconstruction loss, denoted L_FT can fail when normal samples are intrinsically noisier than anomalous samples. In such cases, reconstruction error may rank noisy normal samples as more anomalous than truly anomalous samples, producing a reversal of the intended anomaly ranking. The authors motivate this with a Brownian variance-reversal toy example where high-variance Brownian sequences are normal and low-variance sequences are anomalous, causing the reconstruction baseline to fail badly.
The claims of the paper are that GAPS provides a theoretically motivated and practically effective correction to reconstruction-based anomaly scoring under noise-dominated conditions, while preserving baseline performance in standard conditions. The empirical evidence is built across synthetic experiments, an HRV benchmark, and TSB-AD-U under clean and noise-stress conditions.
Strengths and weaknesses
Strengths:
-
The use of L_FT−L_ZS is conceptually elegant. The paper exploits the pre-trained zero-shot behavior of time-series foundation models and their fine-tuned behavior. This is a good use of foundation models because the zero-shot model is not treated merely as an initialization but as an informative reference model.
-
The paper provides several theoretical results that connect the method to noise cancellation and gradient alignment. Proposition 1 is particularly shows that the expectation of the adaptation gap cancels the target-noise variance term and leaves a bias-contrast term. This directly supports the claim that Diff can be more robust than raw reconstruction loss under noise.
-
The experimental design is coherent. The results show that Diff performs extremely well in the noisy-normal condition but fails in noisy-anomaly and standard conditions. GAPS preserves much of the benefit without collapsing elsewhere.
Weakness:
- The central assumption is that anomalies benefit less from fine-tuning on normals than normal samples do, and that the problematic regime is one where normal samples have higher noise than anomalies. This is an important regime, but it is not universal. In many anomaly-detection applications, anomalies may themselves be noisier, corrupted, or more variable than normal samples. The paper acknowledges this indirectly through the noisy-anomaly synthetic condition, where Diff alone collapses and GAPS fall back to L_FT.
This raises a broader question: how often does the GAPS mechanism activate beneficially on real-world datasets beyond the specific HRV and injected-noise settings? The method may be very useful for a subset of noise-dominated problems.
-
The TSB-AD-U experiments include a clean condition and a pre-registered C-noise condition where Gaussian noise is added to calibration-normal and test-normal windows while anomalies remain clean. The paper states that the released benchmark does not naturally contain the normal-noise regime the method targets, so the authors add noise to normals to exercise the mechanism. This weakens the real-world generality of the benchmark evidence. The HRV experiment is a stronger natural validation, while TSB-AD-U mainly demonstrates controlled robustness under a constructed perturbation.
-
The routing mechanism has several components: calibration z-scores, a block sign test, a dataset-level gate, raw alignment, normalized alignment, hinge clipping, and final convex combination. The ablation shows that the no-gate variant slightly outperforms full GAPS under C-noise, while full GAPS performs best under C-clean. The trade-off could be discussed more clearly.
Questions
-
Clarify how often does the GAPS routing mechanism activate on naturally occurring real-world datasets, without artificial noise injection?
-
How sensitive is the method to calibration-set size and calibration contamination?
-
Does GAPS still work when zero-shot reconstruction quality is poor? Since, time series anomalies also vary with applications- for e.g in multivariate time-series, anomalies can occur due to multiple sensors changing jointly instead of a single time-varying node- reconstruction error might not be sufficient to catch these anomalies. Hence patch based approaches to capture long context and contrastive learning are often used. GAPS will fail in such cases as reconstruction loss (zero-shot) itself is not reliable. Clarify.
Limitations
See questions and weaknesses.
Formatting concerns
NA
2 comments
General response
We apologize for the delayed response and sincerely appreciate your patience.
We thank Reviewer CKzQ for recognizing (S1) the elegance of and the zero-shot model as an informative reference, (S2) the noise-cancellation and alignment theory, and (S3) the coherent three-regime design.
Your comments concern (W1) scope, (W2) constructed C-noise, and (W3) routing trade-offs; your questions concern (Q1) natural activation, (Q2) calibration sensitivity, and (Q3) poor zero-shot reconstruction.
W1. Scope of the Noisy-normal regime
Original reviewer comment: "The central assumption is that anomalies benefit less from fine-tuning on normals than normal samples do...This is an important regime, but it is not universal...how often does the GAPS mechanism activate beneficially on real-world datasets beyond the specific HRV and injected-noise settings?"
Noisy-normal is a non-universal but measurable regime, and the wavelet audit plus UCDDB delimit the setting in which GAPS is relevant.
Thank you for emphasizing this limitation; it prompted both analyses below. In reconstruction-reliable settings GAPS prioritizes : tests fine-tuning benefit, not the noise regime.
We estimated each series' noise level with the Donoho–Johnstone robust estimator applied to the finest-scale wavelet detail coefficients [2]. A series was labelled Noisy-normal when its normal-side was at least 1.5 times the anomaly-side value and remained significant after multiplicity correction. The audit identified 29 of 350 TSB-AD series (8.3%) as Noisy-normal.
For natural validation, we added UCDDB [1], a full-night airflow benchmark that is naturally noisy-normal, scored with the same VUS code. Normal breathing varies cyclically while apnea/hypopnea reduces airflow, so the direction was fixed before scores were inspected.
| Backbone | S_F VUS-PR | GAPS VUS-PR | S_F VUS-ROC | GAPS VUS-ROC |
|---|---|---|---|---|
| DADA | 0.1183 | 0.1435 | 0.3952 | 0.5420 |
| MOMENT | 0.1142 | 0.1567 | 0.4678 | 0.6700 |
| UniTS | 0.1687 | 0.1926 | 0.4736 | 0.6452 |
GAPS improves every cell, on both metrics and all three backbones. Because event prevalence varies by subject we emphasize the paired direction rather than absolute levels, and read the ROC column as recovery from a sub-chance baseline, not a complete fix.
W2. Constructed C-noise
Original reviewer comment: "...the authors add noise to normals to exercise the mechanism. This weakens the real-world generality of the benchmark evidence. The HRV experiment is a stronger natural validation..."
C-noise is a controlled mechanism test, whereas HRV and UCDDB provide the natural-data validation.
We accept this reading: UCDDB is added as injection-free natural validation alongside HRV, and C-noise is retained only as a controlled mechanism test, not as evidence of prevalence.
W3. Routing complexity and trade-off
Original reviewer comment: "The routing mechanism has several components...The ablation shows that the no-gate variant slightly outperforms full GAPS under C-noise... The trade-off could be discussed more clearly."
The seven pieces are two decisions, and the trade-off is between aggressiveness under noise and guaranteed fallback when reconstruction is reliable.
Routing is not seven independent knobs. It is a product of two factors:
Did normal-only fine-tuning actually improve reconstruction on this dataset? answers this with a block sign test on the calibration Diff values, and is binary at the dataset level. How far does this sample deviate from the average normal adaptation? answers this with a hinge-clipped alignment ratio, continuous in at the sample level. The other items you list, z-scoring and the convex combination, are how the two channels are put on a common scale and mixed by .
Full GAPS does not dominate the no-gate variant in both regimes: it is better on C-clean and slightly worse on C-noise. Carrying the aggregation correction described in Q2 into the Table 4 GAPS row gives:
| Aggregate | C-clean PR | C-noise PR | C-clean ROC | C-noise ROC |
|---|---|---|---|---|
| GAPS | 0.3384 | 0.2964 | 0.7379 | 0.6718 |
| no-gate | 0.2944 | 0.3259 | 0.7203 | 0.6856 |
| effect of the gate | +0.0440 | -0.0295 | +0.0176 | -0.0138 |
The C-clean gain from keeping the gate is about 1.5 times the C-noise gain from dropping it in VUS-PR, and 1.3 times in VUS-ROC. The gate also guarantees exact fallback to when calibration shows no adaptation benefit, so we keep it.
Q1. Natural-data activation frequency
Original reviewer question: "Clarify how often does the GAPS routing mechanism activate on naturally occurring real-world datasets, without artificial noise injection?"
Routing activity on C-clean is strongly backbone-dependent, and the spread comes from the dataset gate rather than the sample-level weight.
Across all 350 C-clean series, with window statistics computed within a series and averaged across series:
| Backbone | Series with gate on | Mean r(x) | Windows with r(x)>0 |
|---|---|---|---|
| DADA | 105 (30.0%) | 0.0558 | 16.06% |
| MOMENT | 336 (96.0%) | 0.4791 | 71.90% |
| UniTS | 44 (12.6%) | 0.0125 | 6.39% |
Ten series per backbone are skipped for length and carry no routing value; counting them as inactive is conservative, and on the 340 valid records the gate rates are 30.9%, 98.8%, and 12.9%.
Dividing the two right-hand columns separates the dataset-level cause from the sample-level one: inside gate-passing series the share of windows with is 54% for DADA, 75% for MOMENT, and 51% for UniTS, so the spread is driven almost entirely by the gate. A share near one half is expected by construction, since is normalized so its calibration mean is about 1.
The MOMENT row is evidence about the blend rather than about inactivity. The gate opens on 96% of C-clean series and mean r(x)=0.4791 puts almost half the score weight on , yet C-clean VUS-ROC moves only from 0.7817 to 0.7795 and VUS-PR from 0.3651 to 0.3626. Safety in the clean regime comes not from the router staying off but from the convex combination being well behaved when it is on. We will revise the paper's "stays inactive otherwise" accordingly.
Q2. Calibration size and contamination
Original reviewer question: "How sensitive is the method to calibration-set size and calibration contamination?"
GAPS is sensitive to calibration size, while joint train/calibration contamination lowers absolute performance but preserves a positive tested margin over .
We ran two stress tests. Both use the corrected Table 3 aggregate, where six Mean (all) cells were stale (C-noise VUS-PR is , not 0.3209); per-backbone values and subsets are unchanged.
Both head-training and calibration data were reduced at each fraction:
| Fraction | ΔVUS-PR | ΔVUS-ROC |
|---|---|---|
| 1/16 | -0.0193 | +0.0091 |
| 1/8 | -0.0113 | +0.0271 |
| 1/4 | -0.0036 | +0.0518 |
| 1/2 | +0.0106 | +0.0747 |
| Full | +0.0173 | +0.0855 |
Primary PR becomes negative at 1/4 or less, so calibration size is a genuine limitation, consistent with weaker adaptation and noisier estimates of score scales, , and the block test; the sweep does not separate those effects.
The second stress test evaluates joint contamination of the head-training and calibration-normal sets:
| Joint contamination | S_F PR | GAPS PR | ΔPR | S_F ROC | GAPS ROC | ΔROC |
|---|---|---|---|---|---|---|
| 0% | 0.2791 | 0.2964 | +0.0173 | 0.5863 | 0.6718 | +0.0855 |
| 10% | 0.2504 | 0.2638 | +0.0134 | 0.5480 | 0.6316 | +0.0836 |
Contamination is not harmless: both scores fall. The GAPS margin over is nevertheless preserved (PR , ROC ), so the advantage survives even though the absolute level does not. We report this narrower result and do not call it calibration-only robustness.
Q3. Poor zero-shot reconstruction
Original reviewer question: "Does GAPS still work when zero-shot reconstruction quality is poor?...in multivariate time-series, anomalies can occur due to multiple sensors changing jointly...GAPS will fail in such cases as reconstruction loss (zero-shot) itself is not reliable."
GAPS cannot repair a representation failure shared by both reconstruction channels; the gate can only fall back to .
We agree with this boundary. If both channels miss the anomaly structure, or adaptation creates no class contrast, GAPS cannot recover the signal, and large alone is not decisive because Diff measures relative adaptation, not absolute reconstruction quality. The routing layer does ensure such a failure is not silent: with no aggregate calibration evidence of fine-tuning benefit, and the score reverts exactly to , so GAPS degrades to the standard recipe, not below it. The joint-sensor multivariate setting you describe, where patch-based or contrastive objectives suit better, is outside our claimed scope; we will state this in the Limitations section.
We hope these responses address your concerns and are glad to answer further questions during the discussion period.
References
[1] "St. Vincent's University Hospital / University College Dublin Sleep Apnea Database." PhysioNet, version 1.0.0, 2007, doi:10.13026/C26C7D.
[2] Donoho, David L., and Iain M. Johnstone. "Ideal Spatial Adaptation by Wavelet Shrinkage." Biometrika, 81(3):425-455, 1994.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 4/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The authors consider the use of the reconstruction loss from a given foundation model as the fundamental basis for anomaly detection using such models. In particular, they compute the zero-shot reconstruction loss, and the fine-tuned reconstruction loss, and then compute the differences between these losses. The call this difference (Diff) the “adaptation-gap”, and studied ways to use this as the foundation for improved modeling and analysis of anomaly. They argue that combining this gap (Diff), and the original reconstruction loss from the fine-tuned model provides an improved model for differentiating between anomaly in time series and simple random noise. Detailed experimental results were used to validate the idea, and its performance when compared with SOTA methods.
Strengths and weaknesses
The basic idea is quite interesting, though intuitive. Considering the feedback from the difference between two reconstruction losses, where the two are carefully selected could improve performance.
The use of calibration-anchored approaches, in this paper focused on z-score normalization seemed to have worked quite well. How would other calibration-anchored approaches perform? The authors should show the performance using some other calibration methods.
One question is how the degree or amount of fine-tuning will affect the overall performance. Should this be performed in terms of a family of Diffs, or family of GAPS, where each level of fine-tuning will result in one gap, and these can then be combined for final decision making on the anomaly?
An important element in the work is the weight function r(x). How exactly is this determined?
The key idea in Proposition 1 on noise-cancellation seems to assume simple linearity in the loss function. How would this hold up when the loss function is non-linear, as is often the case.
On Line 132, authors noted that the bound on . But this either requires some proof, or some references that documented that.
The approach showed strong results. However, the results in Table 1 seemed to show that under Noisy anomaly, which is the key differentiator the paper tried to consider, the performance using and did not seem too different. Does that mean that the proposed use of Diff could not improve on the standard reconstruction loss for these cases? These are expected to be the most challenging scenarios.
For comparative results, only three backbones were considered. More comparative methods will provide more confidence on the superior performance. Also, the proposed approach did not seem to work on MOMENT. There should be more discussion on this.
The authors showed results for time in terms of wall-clock recordings. However, there is need for more comprehensive evaluation of resource use, in terms of both time, space, and power consumption. Also, no discussion on the theoretical computational complexity of the approaches proposed.
The comparative results reported should be placed in the context of these type of comprehensive analysis of resource need.
No conclusion nor discussion of the work, or the results.
Minor: Some terms are not clearly defined, eg. , VUS-ROC, etc.
Questions
See above.
Limitations
See above.
Final justification
The authors addressed some of my questions in the rebuttal, and the following up comments. However, I will maintain my current rating.
Formatting concerns
None
3 comments
General response
We apologize for the delayed response and sincerely appreciate your patience.
We sincerely thank Reviewer Cq3N for recognizing (S1) comparing a TFM's fine-tuned and zero-shot reconstruction losses is interesting, and that the careful choice of the two losses is what makes it work, (S2) calibration-anchored z-scoring worked well, and (S3) the approach showed strong results.
Your eleven points are answered below as (W1) calibration, (W2) budget, (W3) routing, (W4) assumptions, (W5) bound, (W6) control, (W7) comparisons, (W8) MOMENT, (W9) resources, (W10) conclusion, and (W11) definitions.
W1. Alternative calibration transforms
Original reviewer comment: "...How would other calibration-anchored approaches perform?"
Channel calibration matters; z-score is not uniquely viable.
Routing was held fixed; aggregates use the corrected Table 3 (W11).
| Transform | Clean PR | Noise PR | Clean ROC | Noise ROC |
|---|---|---|---|---|
| z-score | 0.3384 | 0.2964 | 0.7379 | 0.6718 |
| Robust z | 0.3395 | 0.2960 | 0.7397 | 0.6721 |
| Min-max | 0.3150 | 0.3062 | 0.7077 | 0.6759 |
| None | 0.3344 | 0.2667 | 0.7218 | 0.6030 |
Robust z matches z-score and min-max trades C-clean accuracy for noise stability, so we keep the pre-registered choice. Without calibration, PR drops below : channel calibration matters more than the specific transform.
W2. Fine-tuning budget and family of gaps
Original reviewer comment: "...how the degree or amount of fine-tuning will affect the overall performance...a family of Diffs, or family of GAPS?"
Fine-tuning improves GAPS, but this sweep does not justify checkpoint ensembling.
| Epoch | Clean PR | Noise PR | Clean ROC | Noise ROC |
|---|---|---|---|---|
| 1 | 0.3193 | 0.2745 | 0.7232 | 0.6415 |
| 5 | 0.3251 | 0.2829 | 0.7298 | 0.6571 |
| 10 | 0.3324 | 0.2891 | 0.7337 | 0.6646 |
| 20 | 0.3384 | 0.2964 | 0.7379 | 0.6718 |
GAPS improves monotonically with the budget, and more so under C-noise, as expected if adaptation matters most in the targeted regime. Proposition 2 already writes Diff as a weighted sum of per-step alignment values, so your family-of-gaps reading is its discrete counterpart.
W3. Definition of
Original reviewer comment: "An important element in the work is the weight function r(x). How exactly is this determined?"
Routing is a dataset-level gate times a sample-level weight.
The gate asks a binary dataset-level question: did normal-only fine-tuning improve reconstruction at all? The weight asks a continuous per-sample one: how far below the calibration average does this sample's gradient align with the normal update? Diff enters only when both are nonzero. Restating Eqs. (6)–(9):
is a one-sided block sign test on calibration Diff at ; and are calibration-normal means of and . No test labels enter.
W4. Proposition 1 and nonlinear loss
Original reviewer comment: "...Proposition 1...seems to assume simple linearity in the loss function. How would this hold up when the loss function is non-linear?"
Proposition 1 relies on MSE, not on a linear predictor or a linear-loss approximation.
Terms: is the prediction input (observed window, cache and masks fixed), with zero-mean and independent of , and is model 's own reconstruction error. Four steps:
- Condition on . This freezes , so is a constant vector however nonlinear the predictor is.
- Write the residual as and expand the square.
- Take expectations. kills the cross term, leaving .
- Subtract over . The noise term is common to both, so it cancels and only the bias contrast survives.
The only structural requirement is the squared loss at step 2.
W5. Bound on
Original reviewer comment: "On Line 132...the bound on RDiff(x)...requires some proof, or some references..."
The bound is proved in Appendix A and needs an explicit main-text cross-reference.
We apologize for omitting the Appendix A cross-reference. -smoothness gives per step, and summing yields .
W6. Interpretation of Noisy-anomaly
Original reviewer comment: "...under Noisy anomaly...SGAPS and SF did not seem too different. Does that mean Diff could not improve on the reconstruction loss here?"
Noisy-anomaly is an opposite-regime control in which GAPS should preserve , not improve it with Diff.
The targeted regime is Noisy-normal, where GAPS lifts mean AUC-ROC from 0.2515 to 0.8822. Noisy-anomaly is its mirror image: mean AUC-ROC is 1.0000 for both and GAPS while Diff-only collapses to 0.0001, so the router blocks a wrong channel and preserves the baseline.
W7. Broader comparative methods
Original reviewer comment: "...only three backbones were considered. More comparative methods will provide more confidence."
Broader comparisons add context, not universal superiority. is the relative change from C-clean to C-noise.
| Method | C-clean PR | C-noise PR | Δ% PR | C-clean ROC | C-noise ROC | Δ% ROC |
|---|---|---|---|---|---|---|
| MOMENT S_F | 0.3651 | 0.2758 | -24.5% | 0.7817 | 0.5061 | -35.2% |
| MOMENT GAPS | 0.3626 | 0.3267 | -9.9% | 0.7795 | 0.7222 | -7.3% |
| IForest | 0.2034 | 0.1912 | -6.0% | 0.6020 | 0.5965 | -0.9% |
| LOF | 0.2291 | 0.2017 | -12.0% | 0.6631 | 0.6738 | +1.6% |
| MatrixProfile | 0.3706 | 0.1231 | -66.8% | 0.8456 | 0.5569 | -34.1% |
| KMeansAD | 0.3670 | 0.1382 | -62.3% | 0.7884 | 0.5214 | -33.9% |
| SR | 0.3260 | 0.1972 | -39.5% | 0.8112 | 0.6610 | -18.5% |
| AnomalyTransformer | 0.1071 | 0.0969 | -9.5% | 0.5321 | 0.5629 | +5.8% |
| OmniAnomaly | 0.2983 | 0.2400 | -19.5% | 0.7404 | 0.6174 | -16.6% |
| TranAD | 0.2788 | 0.2072 | -25.7% | 0.7054 | 0.6710 | -4.9% |
| LSTM-AD | 0.3525 | 0.2359 | -33.1% | 0.8042 | 0.6428 | -20.1% |
Classical detectors can lead on C-clean but degrade sharply under noise, so we claim no universal superiority; under C-noise GAPS is the most robust entry. See W8 for the paired reading.
W8. MOMENT results
Original reviewer comment: "...the proposed approach did not seem to work on MOMENT. There should be more discussion..."
On MOMENT the gain is largest, not absent.
On HRV, MOMENT is the one backbone where is already strong (0.9417), so preservation is by design. On TSB-AD-U C-noise it helps most: PR and ROC versus / for DADA/UniTS, because its baseline degrades most ( ROC).
W9. Time, memory, power, energy, and complexity
Original reviewer comment: "...evaluation of resource use, in terms of both time, space, and power consumption...no discussion on the theoretical computational complexity."
Routing adds little incremental resource cost.
Times are the submitted Table 5 values; memory is from a new instrumentation pass over the same configuration, splits, batch rule, and GPU.
| n_total | Encoder (s) | Head FT (s) | GAPS (s) | Peak GPU (MiB) | Activation cache (MiB) | GAPS added (MiB) |
|---|---|---|---|---|---|---|
| 256 | 0.61 | 0.030 | 0.019 | 1611 | 65 | 5.19 |
| 448 | 0.67 | 0.010 | 0.017 | 1660 | 114 | 5.19 |
| 896 | 1.34 | 0.020 | 0.044 | 1774 | 228 | 5.19 |
| 1792 | 2.66 | 0.030 | 0.055 | 2122 | 455 | 8.32 |
Peak memory is dominated by the activation cache and grows linearly; GAPS scoring adds at most 8.32 MiB, draws 74.0 W on average against 432.6 W for the encoder pass, and accounts for 0.7% to 1.9% of total pipeline GPU energy. For head size , epochs , and encoder cost , routing adds on top of , both reusing the encoder cache, with added memory . Placing W7 in this context: the classical detectors there are far cheaper than any TFM pipeline, so that table is about robustness under noise rather than cost, while the figures here bound only what GAPS adds to a TFM one is already running. All values are GPU-side; CPU energy was not instrumented.
W10. Conclusion and discussion
Original reviewer comment: "No conclusion nor discussion of the work, or the results."
We will add a Conclusion and Limitations section along these lines:
Conclusion: GAPS restores ranking in the noise-on-normals regime and defers to elsewhere: Diff is a conditional complement switched on by calibration evidence. Limitations: GAPS depend on the underlying TFM, and Propositions 2 and 3 analyse full-batch updates rather than AdamW.
W11. Undefined terms
Original reviewer comment: "Minor: Some terms are not clearly defined, eg. f*(x), VUS-ROC, etc."
The revision will define (the true noise-free function), VUS-PR/ROC , and at first use.
We also correct Table 3's Mean (all) row, where six cells were stale (C-noise VUS-PR is , not 0.3209); per-backbone values, , and subsets are unchanged.
We thank the reviewer again for the detailed review, which prompted every new analysis above. We would gladly clarify any point during the discussion, and hope these additions merit a reconsideration of your assessment.
Response to Authors Rebuttal
This reviewer thanks the authors for providing more clarifications on the paper and for providing more information. The original critiques and the responses will be put into consideration in the final rating of the paper.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
General response
We apologize for the delayed response and sincerely appreciate your patience.
We sincerely thank Reviewer GbnV for recognizing (S1) the interest of comparing fine-tuned and zero-shot models, (S2) the favorable results against fine-tuned foundation-model detectors, and (S3, in the review summary) the component-level ablations. GAPS uses the pretrained zero-shot model as an informative reference rather than only as an initialization.
Your comments concern (W1) definitions and notation, (W2) non-TFM comparisons, and (W3) limitations; your questions concern (Q1) alignment, (Q2) θ1, and (Q3) zF,zDiff. We answer the weaknesses first.
W1. Definitions and notation
The revision will define the missing terms at first use and remove the notation conflicts that obscured the method.
Thank you for identifying this clarity issue. We apologize that several terms and symbols were not defined at first use.
We will define alignment value, alignment ratio, and θ1 at first use; move θ1=θ0−αG from the appendix proof into Proposition 3; define VUS-PR/VUS-ROC; standardize zLFT to zF; and separate the reused symbols U,z,L. We also correct the
Mean (all)row of Table 3, where six absolute cells retained stale values (e.g., C-noise VUS-PR is (0.2876+0.3267+0.2750)/3=0.2964 rather than the submitted 0.3209); per-backbone values, the Δ% column, and all subsets are unchanged, and the correction makes the aggregate row consistent with Δ%.W2. Non-TFM baselines
Classical detectors can be strong on C-clean but degrade sharply under noise.
Thank you for suggesting broader detector context. We added ten additional non-TFM detectors; VUS-PR is primary and VUS-ROC secondary. Δ% is the relative change from C-clean to C-noise.
Bold marks the best value in each absolute-metric column; the Δ% columns are not bolded. MatrixProfile and KMeansAD lead on C-clean but lose most of that advantage under noise (VUS-PR −66.8% and −62.3%; VUS-ROC −34.1% and −33.9%), so we claim no universal C-clean superiority. Under C-noise, GAPS records the strongest VUS-ROC among the detectors above (0.7222), and the paired MOMENT comparison isolates the contribution on a fixed backbone: VUS-PR 0.2758→0.3267, VUS-ROC 0.5061→0.7222.
W3. Limitations
GAPS has two main limitations: it requires a measurable aggregate fine-tuning benefit on training dataset, and Propositions 2 and 3 do not directly cover AdamW.
We will add a dedicated limitations discussion. If normal-only fine-tuning yields no measurable aggregate benefit on calibration normals, Gbenefit=0 and SGAPS=SF: this is a safe fallback, not an added gain, and the gate may suppress useful Diff evidence. Proposition 1 is an optimizer-independent MSE identity, whereas Propositions 2 and 3 analyze idealized full-batch updates; they do not directly cover the AdamW implementation.