Polar Transformers: $SO(2)^K$-Equivariant Angular Attention for Cryo-EM Image-Set Processing
Joakim Andén, Justus Sagemüller
NeurIPS 2026
TL;DR. The polar transformer is a new neural network architecture that allows integrating information from noisy images related by unknown random rotations
Abstract. Many projection-based imaging modalities reconstruct unknown objects from collections of noisy projections related by unknown in-plane rotations, making effective estimation dependent on rotationally consistent alignment and aggregation. In cryogenic electron microscopy (cryo-EM), the extremely low signal-to-noise ratio (SNR) makes such multi-image integration essential. We introduce the polar transformer, a permutation-equivariant architecture for sets of images built around an -equivariant angular attention mechanism that jointly aligns and aggregates information across images. This architecture leverages a stable polar representation in which we define polar CNN feature extractors and evaluate attention weights over all relative angular shifts efficiently via fast Fourier transforms (FFTs), ensuring equivariance to independent in-plane rotations of each image in the set. We evaluate the polar transformer on simulated cryo-EM images using denoising as a quantitative proxy. A single model trained across set sizes outperforms the best single-image denoiser already for sets of two images and reduces relative mean squared error (MSE) by 47% for images. Using cryoSPARC ab initio reconstruction, we obtain 3D maps from the polar transformer's images at resolutions 2–4 Å finer than those from the best single-image denoiser at all set sizes, and at finer resolutions than maps from the noisy raw images at set sizes of and below.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (oral) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:42 UTC.
- Decision
- Accept (oral)
Read decision
Meta-review
The paper introduces the polar transformer, a new neural network architecture that rotationally aligns and integrates information from multiple images using an angular attention mechanism that guarantees overall rotational equivariance. Specifically, this network takes as input sets of images, where each individual image is treated as a different token. It is evaluated on simulated cryo-EM images using denoising as a quantitative proxy.
The strengths appreciated by the reviewers include well-motivated problem, good theoretical motivation, original and interesting method proposed for cryo-EM images, promising results on synthetic data, and good ablations with the angular attention mechanism.
Meanwhile, reviewers raised some concerns regarding the reliance on synthetic data with idealized supervision, the need for stronger and more up to date baseline comparisons, analysis of scalability and computational cost as the number of input images grows, more rigorous substantiation of the equivariance claims, clarification of the composition and homogeneity of the image sets used, discussion of robustness across noise levels, closer positioning within the existing literature, and consideration of integration into downstream reconstruction pipelines.
The author provides a detailed rebuttal, which effectively addresses reviewers' concerns. Although one reviewer didn’t respond to the rebuttal, other two reviewers maintained or raised their already positive scores, with minor remaining suggestions, including expanding related work in the appendix. I also think it would be quite interesting to see how this interesting approach may perform on experiments with real data. Overall, I think this paper proposes a novel and solid idea that can raise many interests in the community. I would recommend Accept (Spotlight).
Final justification
Overall, I think this paper proposes a novel and solid idea that can raise many interests in the community. I would recommend Accept (Spotlight).
Read meta-review
Meta-review
The paper introduces the polar transformer, a new neural network architecture that rotationally aligns and integrates information from multiple images using an angular attention mechanism that guarantees overall rotational equivariance. Specifically, this network takes as input sets of images, where each individual image is treated as a different token. It is evaluated on simulated cryo-EM images using denoising as a quantitative proxy.
The strengths appreciated by the reviewers include well-motivated problem, good theoretical motivation, original and interesting method proposed for cryo-EM images, promising results on synthetic data, and good ablations with the angular attention mechanism.
Meanwhile, reviewers raised some concerns regarding the reliance on synthetic data with idealized supervision, the need for stronger and more up to date baseline comparisons, analysis of scalability and computational cost as the number of input images grows, more rigorous substantiation of the equivariance claims, clarification of the composition and homogeneity of the image sets used, discussion of robustness across noise levels, closer positioning within the existing literature, and consideration of integration into downstream reconstruction pipelines.
The author provides a detailed rebuttal, which effectively addresses reviewers' concerns. Although one reviewer didn’t respond to the rebuttal, other two reviewers maintained or raised their already positive scores, with minor remaining suggestions, including expanding related work in the appendix. I also think it would be quite interesting to see how this interesting approach may perform on experiments with real data. Overall, I think this paper proposes a novel and solid idea that can raise many interests in the community. I would recommend Accept (Spotlight).
Final justification
Overall, I think this paper proposes a novel and solid idea that can raise many interests in the community. I would recommend Accept (Spotlight).
- Rating
- 6/6
- Confidence
- 3/5
- Quality
- 4/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper introduces the “polar transformer,” a permutation-invariant architecture for sets of cryo-EM projection images that is equivariant to independent in-plane rotations of each image.
The method relies on a carefully constructed polar representation based on Gaussian RBF interpolation, polar CNNs using angular convolutions (equivariant to angular translations), and a novel angular attention mechanism that computes attention over all relative angular shifts via FFTs.
On large-scale simulated cryo-EM data, the polar transformer significantly improves denoising performance over single-image baselines and RELION class averaging, and the denoised images lead to improved downstream ab initio 3D reconstructions
Strengths and weaknesses
Well-motivated SO(2)^K–equivariant design for cryo-EM image sets. The central design choice of treating each image as a token and using an attention mechanism that is equivariant to independent rotations of each token is well-aligned with cryo-EM physics, where each particle image has an unknown in-plane rotation. The formulation in Section 3.3, especially Equations (3)–(6), clearly connects angular shifts in the polar domain with SO(2)^K equivariance in the Cartesian domain.
Technically careful polar representation with stability guarantees. The use of Gaussian RBFs on a Gauss–Jacobi quadrature grid is more sophisticated than standard nearest-neighbor/linear polar interpolation. Proposition 1 rigorously shows that ( P^T P ) approximates a convolution with a Gaussian kernel (\phi), with explicit error terms (Equation (10)). Appendix B further argues approximate isometry and bounded operator norm. The comparison against standard interpolation in Appendix B nicely demonstrates the improved stability of the proposed mapping in practice.
Clean architectural story from polar CNNs to polar transformers. Angular convolutions (Equation (2)) are a natural and efficient way to achieve rotation equivariance, avoiding the complexity of Clebsch–Gordan or Fourier-space equivariant CNNs while still aligning with group-theoretic formulations (Kondor & Trivedi [29]). Building polar CNNs from these layers and then inserting multi-head angular attention yields a conceptually coherent pipeline, summarized well in Figure 2.
Angular attention mechanism is conceptually strong and ablated. The angular attention in Equation (3) and (4) is a meaningful extension of standard dot-product attention: it explicitly searches over relative angular shifts and uses FFTs for efficiency. The ablation in Table 2 shows that replacing angular attention with standard attention (“Std. attention”) hurts performance (Rel. MSE 0.058 vs 0.050 for standard polar transformer under smaller training regime), and reducing the number of heads or blocks also degrades performance. This supports the claim that the SO(2)-aware attention is the key ingredient.
Questions
Are image sets for training always composed of projections from the same molecule, or are they mixed across molecules? In Table 3, when varying the number of images in a set at test time, are the images always from the same underlying 3D structure? Understanding how homogeneous these sets are is critical for extrapolating to mixed or heterogeneous experimental datasets.
Can you provide either (i) an explicit proof sketch of Equation (5) for the angular attention under the continuous, idealized polar transform, or (ii) an empirical measure of equivariance error (e.g., (| f(R_\gamma x) - R_\gamma f(x) | / |x|) over random rotations) to quantify how well the architecture preserves equivariance in practice? This would make the claims around SO(2)^K-equivariance more precise.
You mention in the Introduction that training on real cryo-EM data would require a strategy like Noise2Noise and that the model is “capable of this.” Can you outline a concrete training setup? For example, how would you handle CTF variation, particle heterogeneity, and unknown orientations in a purely self-supervised setting? Any preliminary experiments on real micrographs would substantially strengthen the paper.
Limitations
Evaluation solely on simulated data with an unrealistically strong supervision signal. All results are on synthetic projections obtained from PDB structures with known viewing directions, CTF, and shifts
Weak comparison to modern cryo-EM denoisers and transformer-based pipelines. The only domain-specific baseline is RELION 2D classification/class averaging, which is a generically applicable but relatively old denoising strategy.
Complexity and scalability of angular attention not addressed experimentally. The angular attention mechanism has computational complexity (\mathcal{O}(K^2 L^2 \log L)) (Section 3.3). While Table 1 and Table 3 report throughput (images/s), there is no systematic analysis of scalability as K grows beyond 1000, nor discussion of typical K in realistic workflows (millions of particles per dataset). Given the quadratic dependence on K, the approach may be impractical for large datasets unless heavily batched/subsampled; this tension is not analyzed.
3D reconstruction evaluation is narrow and uses a somewhat outdated ab initio baseline. The reconstruction experiments (Section 4.5) use SyncVoting (ASPIRE) common-lines ab initio with 1000 projections per molecule. This is an interpretable but older approach; many modern pipelines (cryoSPARC, CryoDRGN variants, amortized pose estimators) use more advanced probabilistic models and non-linear refinement.
Formatting concerns
NA
4 comments
Paper is pretty sold interms of technical novelty and analysis.
One comment to authors try to add more related work in the appendix seaction as this would be help community to understand the work. I am seeing that authors address all off my concerns and I belive they will retify my concerns/comments in the final revision of the paper.
I Belive this paper shoud be accept as a Oral paper.
I will increase my score to Strong accept.
All the best !
Thank you very much for your careful reading of both the manuscript and the rebuttal. We appreciate your thoughtful comments throughout the review process. We will certainly expand the related work discussion in the appendix and incorporate the additional references in the final revision. Thank you again for your encouraging assessment!
Update: the constrained model is exactly equivariant
In our response to Reviewer 5Xok (Q2), we reported that constraining the angular LayerNorm affine to be constant along the angular axis removed four orders of magnitude of equivariance error, leaving a residual of a few times whose source we were still investigating. We have now finished this analysis.
The residual is entirely numerical. After correcting an error in our double-precision control, we find that the constrained architecture is exactly -equivariant, and the angular-varying LayerNorm affine was the only non-equivariant component.
Our original control was invalid because the attention module unconditionally casts the query, key, and value tensors to FP32 before the angular FFTs (we have been training models recently in BF16 and this was not well supported by the FFTs). Promoting the model to double precision therefore left all six attention blocks in single precision, so the comparison could not distinguish rounding error from a structural equivariance violation. Removing this confound reduces the measured equivariance error from a few times to about .
Polar-domain equivariance error. In the polar domain, the group action is an exact circular shift of the angular axis, so there is no interpolation error and no floor to subtract. We report the relative equivariance error of the trunk under shifts of 1, 7, 24, and 48 samples on the 96-point angular grid.
| model | relative equivariance error |
|---|---|
| Polar CNN (equivariant by construction), trained | |
| Polar transformer, trained, unconstrained LayerNorm | 0.61–1.17 |
| Polar transformer, unconstrained weights, affine averaged over angle | |
| Polar transformer, trained under the angular-constant constraint | – |
| The same model, recomputed in true double precision | – |
This correction does not affect any reported denoising results. Training and evaluation already run in FP32, so the cast has no effect on accuracy. In particular, the constrained model retains the reported performance (relative MSE versus at , with M fewer parameters) and is the architecture used for the camera-ready paper.
- Rating
- 5/6
- Confidence
- 2/5
- Quality
- 3/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 4/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The manuscript proposes a polar transformers to denoise cryo-EM images. The input of the model are sets of CNN features extracted from input images of several viewpoints. The CNN and Transformer using angular attention are designed to be permutation-invariant to rotations and work on polar coordinates as opposed to Cartesian coordinates. The method is trained on synthetic data with 1000 images per sample.
Strengths and weaknesses
Strengths:
- Good theoretical motivation and implementation of the rotation invariance. The technical details are added in the supplement.
- Innovative approach to the problem setting of denoising in Cryo-EM.
- Code will be made publicly available and is accessible in the supplement.
Weaknesses:
- The evaluation is limited to synthetic data. It would be great to see examples of the performance of real world data.
- Visually, the improvements of this method are minor compared to existing methods.
Minor comments:
- Eq 1: Consider including equations in your sentences using proper punctuation
- l. 289: "unding the rotation" → "undoing".
- l. 394, 411, 473, …: broken references
Questions
Metrics, such as MSE, could be added to the denoised images in Figure 3, otherwise it is hard to appreciate the advantage of the proposed method.
Limitations
yes
Formatting concerns
None.
1 comment
Rebuttal
On the visual gap in Figure 3, and metrics. We adopted the suggestion to add a quantitative metric to every panel in Figures 3 and 6. Each panel will now report its per-image relative MSE, together with zoomed-in views of the regions where the methods differ. The visual difference is smaller than the quantitative difference suggests because most of the improvement is concentrated in high-frequency content. The FRC curves in Figure 5 show this improvement, and it translates into the 30% resolution gain in 3D reconstruction reported in Section 4.5.
We also tested the same network without changing the weights. Using a single image instead of 1,000 images as context increases the relative MSE from 0.046 to 0.257. We report the 44% reduction against the separately trained single-image baseline because the single-image setting is a degenerate configuration of a model trained for image sets rather than a fair standalone baseline.
Real data. We now have preliminary 2D results on held-out experimental EMPIAR particles. The model is trained only on synthetic projections and evaluated zero-shot, so every experimental structure is unseen during training. Each particle is estimated from the opposite half of its image set and then compared with its own held-out observation. This evaluation does not rely on pairing or alignment assumptions.
Raw agreement has a substantial common baseline. At resolutions between 53 and 29 Å, all of these particles share the same broad shape, so even unrelated particle-like images correlate with an observation at roughly 0.10. Because of this, we compare the change relative to a matched control rather than interpreting the raw agreement directly.
Across 14,592 held-out particles, replacing a particle's image set with one from a different protein reduces the mid-band (0.15–0.40 Nyquist) agreement by 0.029 (95% CI [0.016, 0.042]). This effect is consistent for 18 of the 19 EMPIAR structures. On the same data split, a RELION 2D class-averaging baseline—using the standard alignment, classification, and CTF correction pipeline—shows no detectable context effect of its own (-0.003). The paired difference between the methods is therefore 0.032 (95% CI [0.008, 0.056]).
The estimates also remain particle-specific. They do not collapse onto a common class template: the mean off-diagonal correlation is 0.19, compared with 0.87 for the plain average.
There are two important caveats. First, these experiments require a residual-free block, so we use a reduced-depth version of the architecture, although the equivariant angular-attention core is unchanged. Second, these are preliminary 2D results only. We therefore do not make any claims about experimental 3D reconstruction, because our current evaluation does not yet support them. As this response is text only, we cannot include the corresponding image panels here; they will appear in the camera-ready version.
Minor comments. We have corrected the punctuation in Eq. (1), fixed "unding" to "undoing" at line 289, and resolved the broken references at lines 394, 411, and 473, which were caused by eight unresolved bibliography entries. We also corrected a typo in Eq. (4): the value image should be indexed by rather than .
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 4/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposes a novel deep learning solution for denoising cryo-EM data. In particular, the method combines two ideas: a transformer architecture to condition the denoising process of each image on the other images in the dataset, and a equivariant formulation, to respect the symmetries of the problem. Experiments on synthetic data confirms the benefit of both components.
Strengths and weaknesses
The paper is well written and well motivated. The proposed method is generally original. The formulation of a -equivariant method is a nice and neat idea. Moreover, as far as I know, jointly denoising cryo-EM images in a data driven way closes an important gap between classical methods and deep learning solutions. Together with the promising results on synthetic data, these aspects make me feel optimistic about the potential impact of this work.
The main limitation remains the use of synthetic data, although explicitly discussed in the manuscript.
Questions
-
Sec 4.5: why not directly using the proposed method as a backbone for 3D reconstruction methods? I am thinking for example of the amortized method in [33]. Could this also overcome the synthetic data limitation of the supervised training approach adopted?
-
Without diminishing the originality of this work, an online search reveals a few related works on the intersection of cryo-EM and equivariance that the authors might have missed. In particular, [A] previously built (and ) equivariant architectures for cryo-EM images denoising (although using graph-convolution rather than transformer backbones, and a self-supervised loss). Other works [B, C, D, E, F] also adopted some equivariant components (or equivariance losses) for processing cryo-EM data.
-
the data-ablation in Table 3 seems an important study to support the benefit of the joint-denoising approach proposed. I'd encourage the authors to include (part of) it in the main paper to strengthen the presentation.
-
how does the method perform at higher levels of noise? It would be very interesting to see how the number of images should scale with respect to the SNR level for the polar transformer to work (e.g. minimum to have meaningful improvements over and maximum before performance saturation). Similar analysis have been performed in for classical methods, and I wonder if this approach can push beyond their limits.
-
often, cryo-EM datasets can contain many thousands of images. I wonder if the current method can handle more than the 1000 images in input considered here and how far can this be pushed (i.e. beyond the results in Table 3). While I image training with N>>1000 images is very expensive, I wonder if the permutation-invariance of the transformer architecture allows it to generalize to much larger sets than those observed during training. Also, while the quadratic complexity of attention can be a limiting factor, I wonder if the method could be accelerated by just conditioning on a large number N of images, while just predicting few denoised images (i.e. many-to-1 rather than many-to-many prediction), although this might be worth investigating as future work.
-
citation between [40] and [41] seems missing
-
different citations in the appendix are missing (marked with "?")
[A] Cesa et al., Equivariant self-supervised deep pose estimation for Cryo EM, 2023 [B] Granberry et al., SO(3)-Equivariant Representation Learning in 2D Images, 2023 [C] de Ruijter et al., Equivariant amortized inference of poses for cryo-EM, 2024 [D] Arora et al., CryoEMNet driven symmetry-aware molecular reconstruction through deep learning enhanced electron microscopy, 2025 [E] Jiang et al., Towards Foundation Models for Cryo-ET Subtomogram Analysis, 2025 [F] Lie et al., Overcoming the preferred-orientation problem in cryo-EM with self-supervised deep learning, 2025
Limitations
Yes
Final justification
I appreciated the authors' clarification to my doubts and I maintain my very positive recommendation (raising my score even further would require scaled up experiments on real data) for this very interesting paper.
Formatting concerns
No
3 comments
Rebuttal
Unless noted, every relative MSE below is on the 100-molecule held-out test set of Section 4.3 at the stated set size.
Q4 (noise levels; how scales with SNR) We ran a zero-shot sweep over test SNR and set size using the trained model, evaluating roughly held-out images per condition without any retraining. The model was trained at SNR = 0.02.
| test SNR | 0.02 (train) | 0.005 | 0.0025 | 0.00125 |
|---|---|---|---|---|
| relative MSE at | 0.106 | 0.231 | 0.353 | 0.555 |
| relative MSE at | 0.0465 | 0.119 | 0.180 | 0.259 |
| log-log slope of MSE vs. | −0.179 | −0.144 | −0.146 | −0.165 |
Across the full SNR range, the log-log slope changes only modestly, from −0.179 at the training noise level to −0.165 at the lowest SNR we tested. Even at 16× below the training SNR, increasing the set size continues to reduce the error at nearly the same rate.
At SNR = 0.00125, increasing the set size from to reduces the relative MSE from 0.555 to 0.259. For comparison, the best input-independent constant image gives 0.290 on this test set, so is below that baseline whereas is above it. Using this baseline to define a usable noise floor, the crossing point shifts from SNR 0.0034 at to 0.00099 at , corresponding to an empirical scaling of approximately .
These experiments are all zero-shot and therefore include a train/test mismatch in noise level. For SNRs below the training value, we also rescale the input to the magnitude used during training. This is a one-line inference-time normalization and does not require knowledge of the test SNR. We will document this explicitly.
Q5 (sets larger than 1000; many-to-one) We have now extended the evaluation to using a purpose-built test set containing 8192 distinct viewing directions per structure so that every image in the set is a different view. The model is still trained only at .
| 384 | 1000 | 2000 | 3000 | 4000 | 8000 | |
|---|---|---|---|---|---|---|
| relative MSE | 0.0500 | 0.0473 | 0.0461 | 0.0458 | 0.0455 | 0.0453 |
| images/s | 4509 | 2162 | 1135 | 715 | 556 | 243 |
| peak memory, chunked (GiB) | 3.2 | 13.5 | 14.8 | 17.9 | 21.3 | 36.0 |
| peak memory, ordinary (GiB) | 3.2 | 13.5 | 49.0 | OOM | — | — |
The model continues to improve beyond the training set size, although the gains become progressively smaller. Relative MSE decreases by 9.4% between and . Between and , an eightfold increase in set size gives only about a 4% improvement, and the curve changes very little beyond roughly .
We also implemented the suggested many-to-one evaluation scheme. In this case it is exact rather than approximate because the angular softmax is normalized independently within each query row. Computing attention in blocks of queries therefore produces identical outputs while reducing the memory requirement to . On our hardware, the ordinary implementation runs out of memory between and , whereas the chunked version reaches using 36 GiB. Extrapolating the ordinary implementation gives approximately 745 GiB.
For small sets, the behavior is different. At , the polar transformer performs worse than our single-image polar CNN (0.257 at and 0.106 at , compared with 0.082 for the CNN). We believe this is primarily due to the train/test mismatch in set size, since the transformer was trained only at , although we cannot completely exclude an architectural effect. The crossover occurs somewhere between and .
One note on the timings above: the corrected Table 3 sweep () and the sweep reported here were measured on two different machines after we lost access to the A100 system used for the original paper. The throughput values therefore should not be compared directly with the published numbers, or with each other. The relative MSE values are hardware-independent.
Q1 (backbone for 3D reconstruction) We agree that 3D reconstruction is the natural direction for this work, although we would describe its relationship to [33] somewhat differently. Method [33] fits one structure at a time without using information learned across molecules. Our goal is complementary: to train across many structures so that the model acquires a prior that can be transferred to previously unseen data.
The polar transformer is therefore not intended as a direct replacement for the backbone in [33]. Instead, it provides a set-to-set mapping that removes the per-image in-plane rotation nuisance common to pose-marginalizing reconstruction methods while learning an amortized prior over projection images. We have clarified this distinction in the revised discussion.
Regarding synthetic pretraining, we think the approach is promising, although our current evidence is still limited. The set structure naturally provides a self-supervised objective by predicting each subset from the complementary subset and comparing the prediction with the observed particle after applying its CTF. We also now include a transfer experiment on held-out experimental EMPIAR particles. Replacing a particle's set with one from a different protein reduces the mid-band FRC by 0.029 (95% CI [0.016, 0.042]), with the same trend observed for 18 of the 19 structures we tested. This experiment requires a residual-free variant of the architecture but uses the same angular-attention mechanism. It is a 2D experiment only, and we do not view it as evidence for reconstruction performance.
Q2 (related work) Thank you for pointing these references out. They have all been added in the revised manuscript.
The common theme in [A]–[F] is the use of equivariance for pose estimation or representation learning on individual images. Our setting is different because the group acts independently on each element of a set rather than on a single image. Cesa et al. [A] is probably the closest prior work in terms of cryo-EM, equivariance, and self-supervision. The main difference is that our attention mechanism compares two images simultaneously over all relative in-plane rotations through an FFT along the angular dimension, without requiring explicit alignment.
Q3 (promote Table 3) We agree that Table 3 belongs in the main paper.
While preparing the revision we also found a configuration error in the original sweep. The entries reported for and had inadvertently been evaluated with , which also explains the nearly constant throughput values in the original version. The corrected results, computed on roughly held-out images per set size, are:
| 1 | 3 | 10 | 30 | 100 | 300 | 384 | |
|---|---|---|---|---|---|---|---|
| relative MSE | 0.257 | 0.174 | 0.106 | 0.074 | 0.0576 | 0.050 | 0.049 |
| images/s | 1209 | 1165 | 1240 | 1205 | 1048 | 701 | 647 |
The corrected table shows a stronger dependence on set size than the original version, and the throughput now decreases with as expected from the quadratic attention cost. The result is obtained using exactly the same trained weights, so the improvement from 0.257 to 0.049 isolates the benefit of processing sets rather than individual images.
Citations Both citation issues have been corrected. The missing reference between [40] and [41] is Ralston and Rabinowitz on Gauss–Jacobi quadrature. The unresolved appendix citations were due to eight missing bibliography keys (DLMF, Bertero et al., Stein and Weiss, Greengard and Lee, FINUFFT, cuFINUFFT, and Van Heel for the FRC), which have now all been restored.
I thank the authors for the detailed answer. I think the authors addressed all my doubts and I also appreciated their honesty in their reply to Reviewer 5Xok.
Q1. Still, this backbone could be trained for 3D reconstruction on different molecules (each batch contains K images for a single molecule, but during training the model sees batches coming from different molecules), essentially providing a pretrained version of [33], which could generalize to new molecules at inference time. I am not asking the authors to tackle this challenge now, but I find this an exciting direction of future work enabled by this method.
I maintain my very positive recommendation (raising my score further would require scaled up experiments on real data, but that's not necessary for acceptance), and I look forward to seeing the camera ready version of this work!
Thank you for taking the time to carefully review the manuscript and the rebuttal. The analysis resulting from your questions has been quite illuminating and will make the final paper much stronger.
Regarding Q1, this is an important next step for the method, which replaces the denoising head with a reconstruction head. As you can imagine, however, the design of this reconstruction head and the associated training protocols require a significant expansion of the current work.
Comments on the paper
1 comment
Dear Reviewers,
Thanks for your time and efforts to help review this submission and join the discussion. As we approach the end of reviewer-author discussion phase, please follow up to the author if there is still any remaining concern.
Thanks,
AC
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Rebuttal
We have run new experiments for each of the three questions. Unless noted, every relative MSE below is on the 100-molecule held-out test set of Section 4.3, at the stated set size.
Q1 (set composition). The sets in the paper are homogeneous: all K images are projections of the same molecule from different viewing directions. This matches the stage immediately after 2D classification and is also how the experiments in Table 3 were constructed.
We repeated the experiment using heterogeneous sets while keeping everything else fixed (projections, CTF, shifts, and noise). Only the grouping changes. Each set contains J distinct molecules with K=384.
The third row reports the fraction of non-self attention assigned to images of the query's own molecule. Even with eight molecules per set, attention is still concentrated on the correct structure (26.5% versus a 12.3% chance baseline, a 2.16× enrichment), although the separation is incomplete. Performance degrades smoothly as more structures are mixed, reaching a 51% increase in relative MSE at J=8.
Q2 (equivariance). This experiment changed the paper. It showed that the transformer in the submitted version is not equivariant, identified the source of the violation, and led us to replace it with an equivariant variant for the camera-ready paper.
The Cartesian quantity you requested, ∥f(Rγx)−Rγf(x)∥, is reported relative to each model's own rotation round-trip error. This normalization is necessary because interpolation introduces a model-dependent floor.
Our polar CNN is essentially at its interpolation limit. DnCNN, despite being trained on uniformly random in-plane rotations, remains far from equivariant.
This metric is not informative for the polar transformer because most of its output energy lies outside the frequency band occupied by the clean images (74% versus 0.6%), which substantially inflates the interpolation floor. We therefore evaluated equivariance directly in the polar domain, where rotations are exact angular shifts. Under this metric the trained polar transformer is not equivariant: its relative error ranges from 0.61 to 1.17, whereas the same architecture at initialization achieves 4×10−7.
Inspection of the trained model pointed to the angular layer normalization. Our implementation used the default elementwise affine over (channel, radial, angular), allowing the learned scale and bias to vary with angle. Almost all of the variance in these affine parameters is angular (92.8%), and 22 of the 24 tensors are dominated by the first angular harmonic.
Constraining the affine to be constant along the angular dimension restores equivariance. After retraining, the error drops by roughly four orders of magnitude to the low 10−5 range, while relative MSE increases modestly from 0.0576 to 0.0594 at K=100. The constrained model also has 0.88M fewer parameters.
This is now the model used in the paper. Tables 1–3 and Figures 4, 5, and 7 are being regenerated using the constrained architecture, so the final reported results will correspond to a model that is equivariant by construction.
Retraining is still in progress, so we do not want to overstate the final accuracy gap. It was 3.8% at an earlier checkpoint and has already fallen to 3.0%, and we expect further fine-tuning to narrow it further before the camera-ready version.
The remaining equivariance error is also not purely numerical. Recomputing in double precision leaves it essentially unchanged, whereas our polar CNN control improves from roughly 2×10−7 to 4×10−16. We therefore believe a second, much smaller source of equivariance error remains, and are currently isolating it.
While re-deriving the proof we also found a typo in Eq. (4), discussed below.
Q3 (real data / Noise2Noise). We propose a pair-free objective. Each particle is estimated from the opposite half of its own set and compared against its own observation after applying that particle's 2D CTF:
The CTF term is essential. Omitting it encourages the network to reproduce the CTF-corrupted image rather than learning the underlying deconvolution. Unknown in-plane orientations require no additional treatment because they are precisely the nuisance removed by SO(2)K-equivariance. Heterogeneity is handled through the set mechanism evaluated above.
We also considered classical Noise2Noise pair construction. Pairs could be obtained from independent halves of the same exposure or from nearest-neighbor particles, but in our data nearest-neighbor pairs are no more likely to share a viewing direction than a rotation-aligned random particle from the same micrographs (low-band FRC 0.175 versus 0.188 for the null).
We additionally tested whether the architecture uses meaningful set context on experimental data without any real-data training. We evaluated weights trained only on synthetic projections, using held-out experimental EMPIAR particles in a zero-shot setting. Each estimate was constructed from the opposite half of its own set, so no pairing assumption enters.
Across 14,592 particles, replacing a particle's own set with a set from a different protein reduces mid-band (0.15–0.40 Nyquist) agreement by 0.029 (95% CI [0.016, 0.042]), with the effect present in 18 of the 19 structures. For comparison, we repeated the experiment using RELION 2D classification on the same halves. RELION's corresponding context effect is indistinguishable from zero (-0.003), giving a paired difference of 0.032 (95% CI [0.008, 0.056]).
We report the difference rather than the raw agreement because, at 53–29 Å resolution, essentially any particle image shares a coarse overall shape with any other, producing a baseline correlation of roughly 0.10. The differential isolates the contribution of the set context itself.
This evaluation requires a residual-free network, so it uses a reduced-depth variant of the architecture, although the equivariant angular-attention core is unchanged. We also do not make any reconstruction-level claim on experimental data, since our current 3D evaluation does not yet support one.
On scalability. Here K is the context window rather than the dataset size. Evaluating the same model up to K=8000 changes the relative MSE only from 0.0473 to 0.0453, with performance essentially flat beyond K≈3000.
A dataset containing 106 particles is therefore processed as roughly 103 independent sets. The overall computation scales linearly with dataset size, while the K2 attention cost remains a fixed per-set constant. Query chunking removes the memory bottleneck exactly, allowing K=8000 in 36 GiB. The full sweep and measured memory model are included in our response to Reviewer uN8r.
On baselines. Both baseline families were already included in the submission, although we did not make this sufficiently clear. The U-Net baseline is the Topaz-Denoise architecture [5], and the transformer baseline is SWIN-IR; both appear in Table 1. Our Topaz model is trained on our synthetic data rather than initialized from the published Topaz-Denoise weights, so the comparison is like-for-like. We will make the provenance of every baseline explicit in the camera-ready version.
For ab initio reconstruction we chose a common-lines method because it operates directly on denoised images without estimated poses, allowing the comparison to isolate denoising quality. Methods such as cryoSPARC and cryoDRGN introduce additional priors and iterative refinement. We agree that this should also be measured empirically, and we will therefore include a cryoSPARC ab initio comparison in the camera-ready.
Correction to Eq. (4). While re-deriving the proof we found a typo. Inside the double sum, Eq. (4) prints the value image as Sℓzk⊛hvalue, but this should be zk′. As printed, the sum over k′ contains no k′-dependent term and the expression is not equivariant. The implementation uses the correct form, and the camera-ready version has been corrected.
Proof sketch for Eq. (5). Let Sℓ denote angular shift. Since angular convolution commutes with shifts, substituting zk↦Sℓkzk into Eq. (3) simply reindexes the attention scores:
where m=ℓ+ℓk′−ℓk. Because the softmax is taken jointly over (k′,ℓ), this reindexing leaves it unchanged. Applying the same substitution to the corrected Eq. (4) yields
proving Eq. (5). Equation (6) then follows from PRγ≈SℓP (Section 3.2): exact on the angular grid, with the remaining discrepancy arising only from interpolation in the RBF-polar mapping.