potentialpaper

BioSafetyBench: Agentic Cascade Evaluation for the Bio-AI Ecosystem

Yang Cao, Xiaogeng Liu, Shengchao Liu, Chaowei Xiao

NeurIPS 2026

Edit this page

Or clone it with git

The page gets its repository with its first edit, so start in the web editor.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

Abstract. Biological risk is often a property of a cascade rather than a single model output. A generated artifact may become consequential only after transcription, translation, folding, binding, pathway propagation, or host-directed off-target interaction. Existing bio-AI safety evaluations largely grade each model within its own modality, missing downstream risks and inheriting self-grading circularity when model and evaluator share representations. We introduce BioSafetyBench, an agentic cascade-evaluation platform that treats the bio-AI ecosystem as the unit of safety evaluation. BioSafetyBench routes each model-output pair to one of 15 standardized probes over a six-level hierarchy from genome to organism-level outcome. Fixed bridge agents propagate outputs through two causal pathways: Pipeline A follows forward biological cascades, while Pipeline B evaluates CRISPR and siRNA designs through genome- and transcriptome-wide off-target alignment. At every reached level, external frozen evaluators compute domain-native biomarkers and compare them with literature-anchored thresholds, yielding a Cascade Concern Profile and Cascade Depth. Across 25 foundation models, BioSafetyBench surfaces risks invisible to single-modality grading: Influenza neuraminidase designs from ProteinMPNN and ESM-IF1 reach CD = 4; jailbreak prompts inflate gRNA off-target hits 9.05× over baseline, push 48 of 604 gRNAs to Critical, and concentrate Critical siRNA hits on MYC; protein mask-and-fill spans a 32× cross-model gap; GPT-4o complies on all natural-language-guided protein mutation prompts at CD = 2 while Claude Sonnet 4.5 refuses all prompts at CD = 0; and a three-predictor ADMET ensemble misses 30.3% of known clinical toxics. BioSafetyBench is, to our knowledge, the first bio-AI safety benchmark to provide cascade-level risk certificates whose scoring modules are weight- and gradient-flow independent from the model under test by construction.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

add · history

No versions are recorded yet: its preprint, the venues it went to and what they decided, the camera-ready. Missing a version?

We don't know of a submission of this paper to a venue with open reviews. Missing a submission?

Loading the discussion…