Rethinking Contrastive Targets in Radiology Language-Image Pretraining
Update NeurIPS 2026 submission uRbyMugqG7: 11 notes
@openreview[bot] · 2026-11-24 15:56 UTC · 770336b5fe2c ·
reviews/openreview/urbymugqg7/notes/3c1sud8jfu.json added
+++ b/reviews/openreview/urbymugqg7/notes/3c1sud8jfu.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "3C1sud8Jfu",+ "replyTo": "GQAaDXKL06",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Reply to the follow up comments (continued)",+ "comment": "**For Points 1&4**, information loss is precisely the potential consequence of over-correction. However, removing an incentive to distinguish two cases does not force their complete embeddings to be identical, so this is a risk rather than a necessary collapse. Importantly, the practical objective is not to maximize invariance, but to choose a useful operating point between over- and under-correction. A schema covering common findings at a clinically meaningful localization granularity can correct the large number of recurring false-negative conflicts while preserving distinctions such as laterality or anatomical location. CorLIP also does not force all report content into this schema: when no schema-covered fact is extracted from a text unit, we retain only its paired entry as positive, preserving the original image–text pairing signal for such content. The model can therefore receive shared positive supervision for common compatible findings while retaining pair-specific supervision for content outside the schema. This provides a middle ground between a schema so coarse that it suppresses useful distinctions and vanilla CLIP, whose dense paired-identity conflicts can dominate optimization and even prevent successful training.\n\nThis limitation concerns the fidelity of the practical kernel rather than the diagnosis or the general correction principle. Our theory identifies paired identity as misspecified relative to latent clinical compatibility, while CorLIP replaces it with a practical approximation to this reference. Additionally, any method that constructs semantic positives from a finite schema, parser, or similarity measure must make a similar choice about which distinctions define compatibility. An approximation can therefore be imperfect while still being substantially closer to the ideal target than paired identity. Vanilla CLIP represents the opposite extreme of under correction, assigning negative targets even to clinically compatible pairs. For both schemas evaluated, CorLIP improves over vanilla CLIP in every setting, indicating that, in our experiments, the benefit of correcting this identity bias dominates the potential information loss introduced by the approximate schemas. We do not claim that either schema is optimal.\n\n\n\nThis tradeoff also provides concrete guidance for future kernel design. A richer schema could first represent findings as fine grained atomic tuples that include pathology, anatomy, laterality, severity, and uncertainty. This would avoid assigning full compatibility to cases that differ in clinically important details. However, these tuples should not be treated as unrelated flat categories. Clinical ontologies and anatomical hierarchies could instead define graded compatibility. An exact match in finding and location could receive full target mass. Location specific findings could remain distinct while sharing supervision through a common higher level concept. Contradictory assertions would receive none. Such a kernel could preserve distinctions needed for localization and other detailed tasks while allowing the model to learn the clinical structure shared across related findings. Developing and validating these hierarchical and uncertainty aware kernels is an important direction for future work.\n\nWe will expand the revision’s discussion of these trade-offs, limitations, and directions for future kernel design. We really appreciate the in-depth discussion with the reviewers, which is very helpful for us to further improve the quality of our paper. We hope this addresses the reviewer’s central concern, and we welcome further discussion."+ },+ "createdAt": "2026-07-31T05:11:15.706Z",+ "modifiedAt": "2026-11-19T16:44:40.826Z",+ "url": "https://openreview.net/forum?id=uRbyMugqG7¬eId=3C1sud8Jfu",+ "license": "CC-BY-4.0"+}
reviews/openreview/urbymugqg7/notes/5qiwu8vf2q.json added
+++ b/reviews/openreview/urbymugqg7/notes/5qiwu8vf2q.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "5QIWu8vF2q",+ "replyTo": "GQAaDXKL06",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We sincerely thank the reviewer for this thoughtful follow-up. We are glad that the additional experiments and clarifications were helpful. In the revision, we will incorporate the rebuttal’s discussion of our positioning, including the relationship to SupCon and related concepts, into the Related Work and Appendix.\n\nThe reviewer’s remaining observation highlights an important distinction between the general compatibility-correction principle and the invariances induced by a particular schema. Our previous statement about granularity can be made more precise. **We find that the concerns in Points 3 and 1&4 can be understood through the same schema trade-off.**\n\nA schema that is too coarse can produce over-correction: it declares two cases compatible even though they differ in clinically relevant information omitted by the schema. For example, CheXbert-13d does not represent laterality, so an image with a left-sided finding may receive positive target mass for a sentence describing the corresponding right-sided finding. This removes an incentive to preserve a distinction that localization or other fine-grained tasks may require. Pushed to the extreme, such invariance could suppress clinically useful within-finding distinctions.\n\nConversely, making a flat schema increasingly fine can make the correction too sparse. Suppose precise localization is represented using mutually exclusive atomic categories. Right upper lobe pneumonia and right lower lobe pneumonia should remain distinct at the location specific level, but a flat kernel has no mechanism to also express that they share the higher level concept of pneumonia. It therefore preserves the distinction while losing supervision for their shared clinical structure. In the extreme, if every detailed combination of finding, location, and severity defines a separate category, the compatible set can approach only the paired sample, reducing the correction toward vanilla CLIP’s paired identity target.\n\n**This perspective also helps explain Point 3.** On MIMIC, CorLIP-CB’s correction target and the evaluation labels are closely aligned: both originate from the same CheXpert-labeling pipeline and therefore share similar category boundaries, omissions, and annotation conventions. Consequently, distinctions discarded by CheXbert-13d, such as laterality or finer finding subtypes, are often also invisible to the in-domain evaluation. The resulting coarse invariance is therefore not strongly penalized and can even be advantageous by concentrating the representation on exactly the distinctions measured by the MIMIC labels.\n\nCheXpert has the same nominal output categories, but not necessarily the same semantic partition of the data: its test labels are expert annotations, its images come from a different institution, and its subtype and visual distributions may differ. Under this shift, distinctions treated as irrelevant by the coarse MIMIC-aligned schema may become useful intermediate features for recognizing the same final categories robustly. MedGemma-30d preserves more of this clinical structure, which provides a plausible explanation for why CorLIP-MG transfers better to CheXpert despite the shared label vocabulary. The reviewer’s explanation based on annotation provenance is therefore complementary: nominal label-space agreement does not guarantee agreement between the correction-induced invariances and the distinctions used by an expert-labeled OOD evaluation.\n\nAccordingly, we will replace the universal claim with the narrower empirical observation that, among the two schemas evaluated, MedGemma 30d is the stronger fixed default across the three held out evaluations, whereas CheXbert 13d performs better on MIMIC. We will not interpret this as evidence that label space matching or increasing granularity is universally optimal.",+ "title": "Reply to the follow up comments"+ },+ "createdAt": "2026-07-31T05:09:56.429Z",+ "modifiedAt": "2026-11-19T16:44:41.126Z",+ "url": "https://openreview.net/forum?id=uRbyMugqG7¬eId=5QIWu8vF2q",+ "license": "CC-BY-4.0"+}
reviews/openreview/urbymugqg7/notes/dcwhxtwhuv.json added
+++ b/reviews/openreview/urbymugqg7/notes/dcwhxtwhuv.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "DCWhxtwhuV",+ "replyTo": "ZmdcYlH5A0",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We sincerely thank the reviewer for the thoughtful discussion and for reconsidering the score. Your comments helped us better understand and articulate the granularity trade-off, as well as the importance of carefully selecting the correction schema in practice. We will incorporate this discussion prominently into the main paper, including the associated limitations and guidance for future use. We greatly appreciate your constructive feedback and the productive rebuttal process."+ },+ "createdAt": "2026-08-03T17:46:36.786Z",+ "modifiedAt": "2026-11-19T16:44:40.751Z",+ "url": "https://openreview.net/forum?id=uRbyMugqG7¬eId=DCWhxtwhuV",+ "license": "CC-BY-4.0"+}
reviews/openreview/urbymugqg7/notes/f85reslulo.json added
+++ b/reviews/openreview/urbymugqg7/notes/f85reslulo.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "F85ReslulO",+ "replyTo": "VOZylA3IM8",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer D7wg",+ "content": {+ "title": "answer to rebuttal",+ "comment": "Thank you for the thorough rebuttal. \n\nAuthors addressed most of my concerns, and the additional real-data analysis of false negatives in MIMIC-CXR provides additional support for the paper’s central hypothesis. The improved positioning relative to existing contrastive learning approaches, along with clarifications on compatibility and semantic diversity, further strengthen the paper."+ },+ "createdAt": "2026-08-02T18:52:02.339Z",+ "modifiedAt": "2026-11-19T16:44:40.761Z",+ "url": "https://openreview.net/forum?id=uRbyMugqG7¬eId=F85ReslulO",+ "license": "CC-BY-4.0"+}
reviews/openreview/urbymugqg7/notes/i666ikyvdc.json added
+++ b/reviews/openreview/urbymugqg7/notes/i666ikyvdc.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "I666IkyvDC",+ "replyTo": "GQAaDXKL06",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer eJif",+ "content": {+ "comment": "I thank the authors for their thorough rebuttal, including extensive additional motivation and useful experimental results.\n\n### Several things have been made clearer:\n\n* **(2.)** I greatly appreciate the effort the authors have expended in including these experiments and these results mostly address my concerns. I agree that there is a large difference between standard SupCon and contrastive image-text pre-training, but given the grouping CorLIP imposes based on the schema, I believe it would be reasonable to include a discussion in the Appendix (similar to the one the rebuttal provided) clearly differentiating these methods. \n\n* **(5.)** The experimental details clearly strengthen the experiments presented in the paper. \n\n### Still, some of my concerns persist. \n\n* **(3.)** The discussion around this does not fully resolve my concerns. First off I'm not sure that the results in the paper support the claim that “When the downstream label space is known, matching the correction schema to it during pretraining simply uses information already in hand, and is the better choice”. For instance, MedGemma-30d beats CheXbert-13d on CheXpert, even though that should be a case where the labels match exactly. Additionally, since only two schemas are evaluated, the claim that a more granular schema is uniformly better for OOD could be a bit overstated. I imagine that there is a limit to how granular you would want your schema to be, and the provided schemas differ not only in their label spaces but also in their extraction methods. The labels for MIMIC were extracted by the rule-based CheXpert Labeler [5] (which was used to train the CheXbert model leveraged by CorLIP-CB), while the CheXpert test set was annotated by radiologists [6], making schema/class labeling agreement a plausible explanation. \n\n* **(1. & 4.)** I’m familiar with the CLIP radiology literature and acknowledge that this general form of pre-training is useful for much more than zero-shot classification. My comment was more in regards to CorLIP’s main contribution, which allows the representation of different images to become more similar as long as they fall within the same pre-defined category (based on the schema). I think the inclusion of the phrase grounding experiment is good, but it is still quite similar to the ‘’standard’’ zero-shot classification task compared to other more diverse tasks. The main difference is that phrase grounding evaluates the similarity of local representations against a single phrase (which usually refers to a common finding that the schema could potentially incorporate, see Figure 3 in [4]), as opposed to the pooled embeddings against a small vocabulary. This is a good evaluation of the local features, but it still probes the same image-text similarity, unlike tasks such as fine-tuning the image encoder for a specific classification/segmentation, or generating new reports. These tasks were what my original GLoRIA and AFLoc comment was referring to, not their proposed methodologies (I agree with the authors that the axes are orthogonal). My main concern is this: as I hope the authors also would agree, CorLIP does not only resolve a training dynamic issue, it also encourages clustering of images and texts that fall within the same schematic category. This can be very useful as evidenced by the classification performance presented in the paper. Still, a 30-finding schema is coarse relative to the full content of radiology reports, so it is plausible that removing the incentive to distinguish images that agree on all schema-covered findings but differ in content could discard information that more fine-grained tasks depend on. Since I don't think it's reasonable to ask you to run excessive experiments in these domains within the discussion, could the authors motivate why they believe that this would not be a concern? \n\nAll in all, I greatly appreciate the effort put in by the authors, and the rebuttal has improved my assessment of the paper. Concern 3. is the most practical one, and I do believe that some of the claims made regarding the choice of schema are not supported enough (e.g., the matched schema performs worse on CheXpert, granularity is not the only thing that makes the schemas different). Regarding my comments on points 1. & 4., it's not that I believe that a method has to excel at everything, but I do think there's value in acknowledging and somewhat probing potential limitations, trying to see if there is a drawback, something that I think the paper could have done more of. \n\n\nReferences:\n\n[4] Boecking et al. Making the Most of Text Semantics to Improve Biomedical Vision–Language Processing, ECCV, 2022\n[5] Johnson et al. MIMIC-CXR-JPG, a large publicly available database of labeled chest radiographs, arXiv, 2019\n[6] Irvin et al. CheXpert: A Large Chest Radiograph Dataset with Uncertainty Labels and Expert Comparison, AAAI, 2019"+ },+ "createdAt": "2026-07-30T13:37:02.913Z",+ "modifiedAt": "2026-11-19T16:44:40.875Z",+ "url": "https://openreview.net/forum?id=uRbyMugqG7¬eId=I666IkyvDC",+ "license": "CC-BY-4.0"+}
reviews/openreview/urbymugqg7/notes/mcfylyaavo.json modified
+++ b/reviews/openreview/urbymugqg7/notes/mcfylyaavo.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair K9F8","content": {- "metareview": "This paper identifies two failure modes of CLIP-style radiology vision-language pretraining, attributes them to a mismatch between paired-identity contrastive targets and the shared semantic structure of radiology reports, and proposes CorLIP, a compatibility-based target that treats clinically compatible reports as positives. The paper combines theoretical analysis, a synthetic benchmark, and extensive experiments on chest X-ray and CT datasets to support its claims. \n\n-----------------Initial Meta-review-----------------\n\nThe reviewers appreciated the clear progression from empirical observations to theoretical analysis and a simple correction. They found the synthetic CLEVR-Radiology benchmark useful for isolating the proposed mechanism, and considered the compatibility-based objective an effective and practical modification that consistently improves stability and zero-shot performance. \n\nThe main concerns from the reviewers and this AC include: \n\nFirst, the paper should better position its novelty with respect to existing work on false negatives, multi-positive contrastive learning, and related approaches that address imperfect contrastive targets. \n\nSecond, the dependence of CorLIP on the chosen compatibility schema deserves further discussion, including how schema design affects downstream performance and the generality of the learned representations. \n\nThird, while the empirical results are strong, additional analysis of generalization beyond chest radiology, the CT experiments, and the practical cost of the compatibility preprocessing would further strengthen the paper. \n\nFourth, although the theoretical analysis of the proposed failure mechanism is interesting and well motivated, the proposed correction appears somewhat heuristic. CorLIP relies on a manually designed compatibility schema extracted from reports, and the results depend on the chosen schema. \n\nFifth, The evidence supporting the generality of the proposed diagnosis is somewhat limited. The two optimization phenomena are directly demonstrated on only a single real chest X-ray dataset (MIMIC-CXR) and reproduced on the synthetic CLEVR-Radiology benchmark. It remains unclear whether the same phenomena also occur on other real CXR datasets or 3D CT. In addition, although the paper states that the proposed correction transfers to 3D CT, I could not locate the corresponding quantitative results in the manuscript. \n\nPlease address the following points in the rebuttal: \n\n(1) Please clarify the novelty of the proposed diagnosis and correction relative to existing work on false negatives, multi-positive contrastive learning, and related target-correction methods. \n\n(2) Please clarify how the choice of compatibility schema affects the learned representations and downstream performance, and discuss the generality of the proposed compatibility formulation. \n\n(3) Please discuss the generality of the proposed diagnosis. In particular, are the reported optimization phenomena observed beyond MIMIC-CXR (e.g., on other CXR datasets or CT), and please clarify the missing quantitative results for the claimed CT transfer experiment.\n\n---------------Final Meta-review-----------------\n\nI have reviewed the authors' rebuttal, the discussion, and the reviewers' final assessments. The rebuttal substantially addresses the main concerns raised in the initial meta-review. The authors better position the contribution relative to prior work on false negatives and multi-positive contrastive learning, clarify the role and practical cost of the compatibility schema, and provide additional evidence supporting the proposed diagnosis, including results on 3D CT. The reviewers responded positively to these clarifications, with the final assessments supporting acceptance. \n\nSome limitations remain, particularly regarding the dependence on the choice of compatibility schema and the generality of the learned representations to downstream tasks beyond those evaluated. However, the authors have appropriately clarified and narrowed their claims, and I do not consider these remaining limitations to outweigh the paper's strengths. Overall, the paper provides a well-motivated analysis of an important failure mode in radiology vision-language pretraining, supported by theoretical analysis, controlled synthetic experiments, and extensive real-data evaluation. I therefore recommend accepting the paper."+ "metareview": "This paper identifies two failure modes of CLIP-style radiology vision-language pretraining, attributes them to a mismatch between paired-identity contrastive targets and the shared semantic structure of radiology reports, and proposes CorLIP, a compatibility-based target that treats clinically compatible reports as positives. The paper combines theoretical analysis, a synthetic benchmark, and extensive experiments on chest X-ray and CT datasets to support its claims. \n\n-----------------Initial Meta-review-----------------\n\nThe reviewers appreciated the clear progression from empirical observations to theoretical analysis and a simple correction. They found the synthetic CLEVR-Radiology benchmark useful for isolating the proposed mechanism, and considered the compatibility-based objective an effective and practical modification that consistently improves stability and zero-shot performance. \n\nThe main concerns from the reviewers and this AC include: \n\nFirst, the paper should better position its novelty with respect to existing work on false negatives, multi-positive contrastive learning, and related approaches that address imperfect contrastive targets. \n\nSecond, the dependence of CorLIP on the chosen compatibility schema deserves further discussion, including how schema design affects downstream performance and the generality of the learned representations. \n\nThird, while the empirical results are strong, additional analysis of generalization beyond chest radiology, the CT experiments, and the practical cost of the compatibility preprocessing would further strengthen the paper. \n\nFourth, although the theoretical analysis of the proposed failure mechanism is interesting and well motivated, the proposed correction appears somewhat heuristic. CorLIP relies on a manually designed compatibility schema extracted from reports, and the results depend on the chosen schema. \n\nFifth, The evidence supporting the generality of the proposed diagnosis is somewhat limited. The two optimization phenomena are directly demonstrated on only a single real chest X-ray dataset (MIMIC-CXR) and reproduced on the synthetic CLEVR-Radiology benchmark. It remains unclear whether the same phenomena also occur on other real CXR datasets or 3D CT. In addition, although the paper states that the proposed correction transfers to 3D CT, I could not locate the corresponding quantitative results in the manuscript. \n\nPlease address the following points in the rebuttal: \n\n(1) Please clarify the novelty of the proposed diagnosis and correction relative to existing work on false negatives, multi-positive contrastive learning, and related target-correction methods. \n\n(2) Please clarify how the choice of compatibility schema affects the learned representations and downstream performance, and discuss the generality of the proposed compatibility formulation. \n\n(3) Please discuss the generality of the proposed diagnosis. In particular, are the reported optimization phenomena observed beyond MIMIC-CXR (e.g., on other CXR datasets or CT), and please clarify the missing quantitative results for the claimed CT transfer experiment.\n\n---------------Final Meta-review-----------------\n\nI have reviewed the authors' rebuttal, the discussion, and the reviewers' final assessments. The rebuttal substantially addresses the main concerns raised in the initial meta-review. The authors better position the contribution relative to prior work on false negatives and multi-positive contrastive learning, clarify the role and practical cost of the compatibility schema, and provide additional evidence supporting the proposed diagnosis, including results on 3D CT. The reviewers responded positively to these clarifications, with the final assessments supporting acceptance. \n\nSome limitations remain, particularly regarding the dependence on the choice of compatibility schema and the generality of the learned representations to downstream tasks beyond those evaluated. However, the authors have appropriately clarified and narrowed their claims, and I do not consider these remaining limitations to outweigh the paper's strengths. Overall, the paper provides a well-motivated analysis of an important failure mode in radiology vision-language pretraining, supported by theoretical analysis, controlled synthetic experiments, and extensive real-data evaluation. I therefore recommend accepting the paper.",+ "final_justification": "I have reviewed the authors' rebuttal, the discussion, and the reviewers' final assessments. The rebuttal substantially addresses the main concerns raised in the initial meta-review. The authors better position the contribution relative to prior work on false negatives and multi-positive contrastive learning, clarify the role and practical cost of the compatibility schema, and provide additional evidence supporting the proposed diagnosis, including results on 3D CT. The reviewers responded positively to these clarifications, with the final assessments supporting acceptance. \n\nSome limitations remain, particularly regarding the dependence on the choice of compatibility schema and the generality of the learned representations to downstream tasks beyond those evaluated. However, the authors have appropriately clarified and narrowed their claims, and I do not consider these remaining limitations to outweigh the paper's strengths. Overall, the paper provides a well-motivated analysis of an important failure mode in radiology vision-language pretraining, supported by theoretical analysis, controlled synthetic experiments, and extensive real-data evaluation. I therefore recommend accepting the paper."},"createdAt": "2026-07-22T14:17:14.500Z",- "modifiedAt": "2026-11-18T15:18:23.316Z",+ "modifiedAt": "2026-11-19T04:59:06.000Z","url": "https://openreview.net/forum?id=uRbyMugqG7¬eId=mCfYLYAAvO","license": "CC-BY-4.0"}
reviews/openreview/urbymugqg7/notes/pmpmzzptcn.json added
+++ b/reviews/openreview/urbymugqg7/notes/pmpmzzptcn.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "pMPMZzpTcN",+ "replyTo": "AVK0Nxqksn",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 5k2S",+ "content": {+ "comment": "I appreciate the authors’ rebuttal. It addressed my questions and concerns well. In particular, the authors clarified that fine-grained schemas perform better outside MIMIC, and that the apparent gains of CheXbert-based methods on MIMIC are largely due to alignment with CheXpert-derived evaluation labels. They also explain convincingly why sentence-level comparisons are more appropriate than report-level ones for their proposed correction. I maintain my positive assessment."+ },+ "createdAt": "2026-07-31T22:45:16.741Z",+ "modifiedAt": "2026-11-19T16:44:40.815Z",+ "url": "https://openreview.net/forum?id=uRbyMugqG7¬eId=pMPMZzpTcN",+ "license": "CC-BY-4.0"+}
reviews/openreview/urbymugqg7/notes/tlgvjgm62s.json added
+++ b/reviews/openreview/urbymugqg7/notes/tlgvjgm62s.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "tLgvjgm62s",+ "replyTo": "I666IkyvDC",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "As the discussion period is coming to an end, we would appreciate it if you could let us know whether our response has addressed your concerns. We would be happy to provide any further clarification."+ },+ "createdAt": "2026-08-02T17:16:55.648Z",+ "modifiedAt": "2026-11-19T16:44:40.746Z",+ "url": "https://openreview.net/forum?id=uRbyMugqG7¬eId=tLgvjgm62s",+ "license": "CC-BY-4.0"+}
reviews/openreview/urbymugqg7/notes/yr04dmwwq3.json added
+++ b/reviews/openreview/urbymugqg7/notes/yr04dmwwq3.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Yr04dmwWq3",+ "replyTo": "pMPMZzpTcN",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for your thoughtful feedback and continued positive assessment. We greatly appreciate it!"+ },+ "createdAt": "2026-08-02T17:13:25.593Z",+ "modifiedAt": "2026-11-19T16:44:40.762Z",+ "url": "https://openreview.net/forum?id=uRbyMugqG7¬eId=Yr04dmwWq3",+ "license": "CC-BY-4.0"+}
reviews/openreview/urbymugqg7/notes/z5of9ujz1u.json added
+++ b/reviews/openreview/urbymugqg7/notes/z5of9ujz1u.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "z5oF9UjZ1U",+ "replyTo": "F85ReslulO",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We sincerely thank the reviewer for the positive assessment and for recognizing the value of our additional analysis and clarifications. We are glad that the real-data false-negative analysis and the improved positioning helped strengthen the paper’s central motivation. We will incorporate these discussions and clarifications into the revised manuscript. We greatly appreciate your thoughtful feedback throughout the review process."+ },+ "createdAt": "2026-08-03T17:47:24.523Z",+ "modifiedAt": "2026-11-19T16:44:40.760Z",+ "url": "https://openreview.net/forum?id=uRbyMugqG7¬eId=z5oF9UjZ1U",+ "license": "CC-BY-4.0"+}
reviews/openreview/urbymugqg7/notes/zmdcylh5a0.json added
+++ b/reviews/openreview/urbymugqg7/notes/zmdcylh5a0.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "ZmdcYlH5A0",+ "replyTo": "tLgvjgm62s",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer eJif",+ "content": {+ "comment": "Thank you for your thorough discussion around these two points. \n\nAs the authors state, the granularity trade-off occurs in many contrastive settings and is not unique to CorLIP. Therefore, while I believe there are still limitations, I do find the method a practically relevant way to steer representations, and explicitly discussing the trade-off in the main paper will better facilitate appropriate adoption (e.g., thinking twice about which schema to use).\n\nAs such, I will increase my score to a 4. Thank you for a productive rebuttal."+ },+ "createdAt": "2026-08-03T09:30:47.553Z",+ "modifiedAt": "2026-11-19T16:44:40.750Z",+ "url": "https://openreview.net/forum?id=uRbyMugqG7¬eId=ZmdcYlH5A0",+ "license": "CC-BY-4.0"+}