Rethinking Contrastive Targets in Radiology Language-Image Pretraining
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 20:34 UTC · a8acd9ca242e ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,31 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "uRbyMugqG7"- }- ],- "title": "Rethinking Contrastive Targets in Radiology Language-Image Pretraining",- "authors": [- "Yunhe Gao",- "Ashwin Kumar",- "Jiaming Liu",- "Chong Wang",- "Maya Varma",- "Fuying Wang",- "Stefania L Moroianu",- "Louisa Fay",- "Sergios Gatidis",- "Akshay S Chaudhari",- "Curtis Langlotz"- ],- "abstract": "CLIP-style contrastive image--text pretraining is widely used in radiology data, where each image is paired with one report and every other report in the batch is treated as a negative. Under this recipe, two failures appear, neither systematically addressed by existing contrastive learning theory: zero-shot evaluation peaks then degrades while training loss keeps decreasing, and training fails to learn at all at large batches. We hypothesize the cause is structural rather than radiology-specific: many unpaired reports share clinical findings with a given image, so CLIP's paired-identity target is systematically biased, not merely noisy. To test this, we construct CLEVR-Radiology, a synthetic testbed that preserves only this overlapping-fact structure and reproduces both failures. With evidence that the structure is sufficient to reproduce the failures, we develop a target-misspecification theory that derives both failures from a single deterministic gradient bias amplified by batch size, and use it to motivate a minimal compatibility-based correction, CorLIP: a text is treated as positive whenever its clinical assertions agree with the image, with no other change to the training pipeline. Beyond benchmark improvements, CorLIP removes the post-peak degradation, makes large-batch training succeed where it previously collapsed, substantially amplifies the gains from more data, and is the only configuration that remains stable up to B=2048. The correction also transfers from chest X-ray to 3D CT modalities.",- "year": 2026,- "venue": "NeurIPS 2026",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "bf064850-17e7-49d2-8cfd-34417b6a9ed5"}
paper.json added
+++ b/paper.json@@ -0,0 +1,21 @@+{+ "title": "Rethinking Contrastive Targets in Radiology Language-Image Pretraining",+ "authors": [+ "Yunhe Gao",+ "Ashwin Kumar",+ "Jiaming Liu",+ "Chong Wang",+ "Maya Varma",+ "Fuying Wang",+ "Stefania L Moroianu",+ "Louisa Fay",+ "Sergios Gatidis",+ "Akshay S Chaudhari",+ "Curtis Langlotz"+ ],+ "abstract": "CLIP-style contrastive image--text pretraining is widely used in radiology data, where each image is paired with one report and every other report in the batch is treated as a negative. Under this recipe, two failures appear, neither systematically addressed by existing contrastive learning theory: zero-shot evaluation peaks then degrades while training loss keeps decreasing, and training fails to learn at all at large batches. We hypothesize the cause is structural rather than radiology-specific: many unpaired reports share clinical findings with a given image, so CLIP's paired-identity target is systematically biased, not merely noisy. To test this, we construct CLEVR-Radiology, a synthetic testbed that preserves only this overlapping-fact structure and reproduces both failures. With evidence that the structure is sufficient to reproduce the failures, we develop a target-misspecification theory that derives both failures from a single deterministic gradient bias amplified by batch size, and use it to motivate a minimal compatibility-based correction, CorLIP: a text is treated as positive whenever its clinical assertions agree with the image, with no other change to the training pipeline. Beyond benchmark improvements, CorLIP removes the post-peak degradation, makes large-batch training succeed where it previously collapsed, substantially amplifies the gains from more data, and is the only configuration that remains stable up to B=2048. The correction also transfers from chest X-ray to 3D CT modalities.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}