potentialpaper

Rethinking Contrastive Targets in Radiology Language-Image Pretraining

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 20:34 UTC · a8acd9ca242e ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,31 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "uRbyMugqG7"
- }
- ],
- "title": "Rethinking Contrastive Targets in Radiology Language-Image Pretraining",
- "authors": [
- "Yunhe Gao",
- "Ashwin Kumar",
- "Jiaming Liu",
- "Chong Wang",
- "Maya Varma",
- "Fuying Wang",
- "Stefania L Moroianu",
- "Louisa Fay",
- "Sergios Gatidis",
- "Akshay S Chaudhari",
- "Curtis Langlotz"
- ],
- "abstract": "CLIP-style contrastive image--text pretraining is widely used in radiology data, where each image is paired with one report and every other report in the batch is treated as a negative. Under this recipe, two failures appear, neither systematically addressed by existing contrastive learning theory: zero-shot evaluation peaks then degrades while training loss keeps decreasing, and training fails to learn at all at large batches. We hypothesize the cause is structural rather than radiology-specific: many unpaired reports share clinical findings with a given image, so CLIP's paired-identity target is systematically biased, not merely noisy. To test this, we construct CLEVR-Radiology, a synthetic testbed that preserves only this overlapping-fact structure and reproduces both failures. With evidence that the structure is sufficient to reproduce the failures, we develop a target-misspecification theory that derives both failures from a single deterministic gradient bias amplified by batch size, and use it to motivate a minimal compatibility-based correction, CorLIP: a text is treated as positive whenever its clinical assertions agree with the image, with no other change to the training pipeline. Beyond benchmark improvements, CorLIP removes the post-peak degradation, makes large-batch training succeed where it previously collapsed, substantially amplifies the gains from more data, and is the only configuration that remains stable up to B=2048. The correction also transfers from chest X-ray to 3D CT modalities.",
- "year": 2026,
- "venue": "NeurIPS 2026",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "bf064850-17e7-49d2-8cfd-34417b6a9ed5"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,21 @@
+{
+ "title": "Rethinking Contrastive Targets in Radiology Language-Image Pretraining",
+ "authors": [
+ "Yunhe Gao",
+ "Ashwin Kumar",
+ "Jiaming Liu",
+ "Chong Wang",
+ "Maya Varma",
+ "Fuying Wang",
+ "Stefania L Moroianu",
+ "Louisa Fay",
+ "Sergios Gatidis",
+ "Akshay S Chaudhari",
+ "Curtis Langlotz"
+ ],
+ "abstract": "CLIP-style contrastive image--text pretraining is widely used in radiology data, where each image is paired with one report and every other report in the batch is treated as a negative. Under this recipe, two failures appear, neither systematically addressed by existing contrastive learning theory: zero-shot evaluation peaks then degrades while training loss keeps decreasing, and training fails to learn at all at large batches. We hypothesize the cause is structural rather than radiology-specific: many unpaired reports share clinical findings with a given image, so CLIP's paired-identity target is systematically biased, not merely noisy. To test this, we construct CLEVR-Radiology, a synthetic testbed that preserves only this overlapping-fact structure and reproduces both failures. With evidence that the structure is sufficient to reproduce the failures, we develop a target-misspecification theory that derives both failures from a single deterministic gradient bias amplified by batch size, and use it to motivate a minimal compatibility-based correction, CorLIP: a text is treated as positive whenever its clinical assertions agree with the image, with no other change to the training pipeline. Beyond benchmark improvements, CorLIP removes the post-peak degradation, makes large-batch training succeed where it previously collapsed, substantially amplifies the gains from more data, and is the only configuration that remains stable up to B=2048. The correction also transfers from chest X-ray to 3D CT modalities.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}