potentialpaper

MedIGen: Towards Reliable Medical Illustration Generation via Interleaved Introspective Reasoning

Import NeurIPS 2026 submission RyrXhwjZ2I: 7 notes

@openreview[bot] · 2026-11-22 17:56 UTC · 91f64f0acebe ·

Evidence

reviews/openreview/ryrxhwjz2i/forms.json added

+++ b/reviews/openreview/ryrxhwjz2i/forms.json
@@ -0,0 +1,227 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ },
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "quality",
+ "clarity",
+ "significance",
+ "originality"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 6
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 5
+ },
+ {
+ "key": "quality",
+ "label": "Quality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "clarity",
+ "label": "Clarity",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "significance",
+ "label": "Significance",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "originality",
+ "label": "Originality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "contribution_type",
+ "label": "Contribution type",
+ "type": "choice"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "strengths_and_weaknesses",
+ "label": "Strengths and weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions",
+ "label": "Questions",
+ "type": "text"
+ },
+ {
+ "key": "limitations",
+ "label": "Limitations",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ },
+ {
+ "key": "paper_formatting_concerns",
+ "label": "Formatting concerns",
+ "type": "text"
+ },
+ {
+ "key": "ethical_concerns",
+ "label": "Ethical concerns",
+ "type": "choice"
+ },
+ {
+ "key": "code_of_conduct_acknowledgement",
+ "label": "Code of conduct",
+ "hidden": true
+ },
+ {
+ "key": "responsible_reviewing_acknowledgement",
+ "label": "Responsible reviewing",
+ "hidden": true
+ }
+ ]
+ },
+ "Rebuttal": {
+ "label": "Rebuttal",
+ "fields": [
+ {
+ "key": "rebuttal",
+ "label": "Rebuttal",
+ "type": "text"
+ }
+ ]
+ },
+ "Ethics_Review": {
+ "label": "Ethics review",
+ "fields": [
+ {
+ "key": "scope_of_ethics_concerns",
+ "label": "Scope",
+ "type": "choice"
+ },
+ {
+ "key": "ethics_review",
+ "label": "Ethics review",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ryrxhwjz2i/notes/ezkcj6yihf.json added

+++ b/reviews/openreview/ryrxhwjz2i/notes/ezkcj6yihf.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "EZKCJ6YiHf",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer iiC6",
+ "content": {
+ "summary": "This work addresses medical illustration generation, arguing that this problem is not a simple text-to-image generation but a more complex reasoning task where visually plausible outputs may still contain anatomical or procedural errors. Authors introduce MedIGen, a unified multimodal (text + image) model built on Janus-Pro that replaces one-pass image generation with an interleaved refinement of the generated images through self-reflection. The model is trained through three stages: pretraining on 1.21 million medical illustration-caption pairs, supervised mixture training over generation, self-reflection, and re-generation skills, and GRPO-based reinforcement learning with dual-level rewards targeting both generation quality and image understandability. In addition, the authors introduce IlluGenBench, a benchmark containing 296 medical illustration tasks and 9,015 rubric criteria generated with GPT-5.1 and refined by experts. Experimental results show substantial improvements over a wide variety of open-source generation and reasoning models, with MedIGen achieving the best reported performance on IlluGenBench.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "The paper tackles an interesting problem, correctly identifying that visually convincing outputs may still be medically invalid, and the proposed introspective refinement framework is well thought of. The idea of explicitly coupling generation with self-reflection and corrective re-generation fits well with unified multimodal architectures. The three-stage training pipeline and the benchmark creation are equally significant and well-motivated, with IlluGenBench addressing an important evaluation gap by moving beyond generic text-image alignment metrics and introducing expert-guided rubric-based assessment focused on medical correctness. \nThe empirical results are generally strong. MedIGen substantially outperforms its Janus-Pro base model and achieves large gains over other open-source baselines on the proposed benchmark despite not reaching the performances of commercial models. The stage-wise ablations support the value of each training component, while also presenting interesting results about failure cases, inference efficiency and cross-category analysis, supported by an extensive appendix. Authors also provide evidence that the model's main remaining bottleneck lies in converting identified errors into successful visual corrections rather than error detection itself. \nSeveral aspects, however, weaken the strength of the claims. Related to previous acknowledgment of the bottleneck, authors repeatedly emphasize reliable generation, but performance remains relatively weak on disease illustrations, with the expert audit showing that re-generation overall frequently fails even after successful error detection. Thus, the improvements are relative rather than robust medical correctness guarantees. \nMoreover, IlluGenBench, the rubric generation pipeline and the automatic evaluation protocol are all introduced by the authors. Although expert involvement is described and human agreement with the judge is analyzed, the paper remains dependent on an MLLM-as-judge framework and a benchmark construction process that may share biases with the proposed methodology. Independent validation on existing medical image-generation benchmarks or broader external evaluation would strengthen confidence in the reported gains. \nThe contribution of the RL stage also appears limited in the main benchmark metric (+0.03 absolute improvement). While justified in the appendix, the main paper would benefit from a clearer demonstration that the dual-level reward design itself is necessary. Some other methodological details would also benefit from a stronger discussion, such as quality and diversity of the 150K supervised trajectories.",
+ "quality": 3,
+ "clarity": 4,
+ "significance": 4,
+ "originality": 4,
+ "questions": "Additional evaluations on external benchmarks or datasets should be provided to demonstrate that the observed gains generalize beyond the proposed benchmark.\nCan the authors provide a stronger ablation comparing no RL, standard image-level RL and dual-level RL (proposed)? This would clarify whether the proposed reward decomposition is responsible for the gains.\nIs there a specific failure pattern over the failure cases for the disease images? Is there evidence that suggests that further reflection iterations would solve?\nSince GPT-5.1 is involved in generating captions and initial rubric criteria, how sensitive are benchmark results to rubric wording? I think the paper would benefit from proving that results are not overly dependent on benchmark generation.",
+ "limitations": "The authors discuss several limitations, including weaker performance on disease illustrations and the gap between error detection and successful correction, but the paper could more explicitly discuss limitations related to benchmark construction, dependence on the MLLM-as-judge framework and potential bias introduced by AI-assisted rubric generation. These should be acknowledged more clearly.",
+ "rating": 5,
+ "confidence": 3,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "No major formatting, anonymity, or policy violations were observed. The paper appears compliant with standard submission requirements.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The rebuttal addressed most of my concerns. Therefore, I believe with the proposed revisions the paper is ready for acceptance."
+ },
+ "createdAt": "2026-06-22T17:15:02.549Z",
+ "modifiedAt": "2026-11-18T13:35:07.372Z",
+ "url": "https://openreview.net/forum?id=RyrXhwjZ2I&noteId=EZKCJ6YiHf",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ryrxhwjz2i/notes/iyadlpjfb8.json added

+++ b/reviews/openreview/ryrxhwjz2i/notes/iyadlpjfb8.json
@@ -0,0 +1,19 @@
+{
+ "schema": "review/1",
+ "id": "iYADLPjFB8",
+ "replyTo": null,
+ "kind": "decision",
+ "invitation": "Decision",
+ "signature": "Program Chairs",
+ "content": {
+ "title": "Paper Decision",
+ "decision": "Accept (poster)",
+ "comment": "",
+ "metareview": "This paper introduces MedIGen, a unified model for medical illustration generation that replaces one-pass synthesis with an interleaved \"generate-reflect-refine\" reasoning process. Key strengths include a well-motivated problem addressing biomedical validity over mere visual plausibility, a comprehensive three-stage training pipeline, and the introduction of IlluGenBench, a rigorous rubric-driven evaluation benchmark. Despite its strong motivation and comprehensive evaluation resources, the reviewers raised several substantial concerns in the initial reviews that needed to be addressed:\n1) Limited novelty: The technical framework combines existing components, such as domain pretraining, generate-reflect-refine cycles, GRPO, and MLLM-based rewards, without introducing sufficiently distinct core methodologies, leading concerns that the work resembles a benchmark or dataset contribution rather than a novel core algorithmic advance. \n2) Potentially biased evaluation: The reliance on MLLM-as-judge frameworks and the authors' internally constructed benchmark introduces potential circularity, alignment biases, and shared vulnerabilities with the proposed generation methodology. \n3) Incomplete evaluation: The empirical study lacks stronger test-time and agent-based baselines, controlled ablations isolating the reflection text, and external validation datasets to prove generalization beyond the proposed benchmark. \n4) Overstated claims: The manuscript repeatedly emphasizes absolute \"reliability,\" yet empirical results reveal persistent failure modes in disease illustrations, limited absolute score gains, and a significant bottleneck where the model frequently fails to correct errors even when they are successfully detected. \n\nI have carefully read the authors' rebuttal and followed the subsequent reviewer discussions. The authors submitted a thorough rebuttal that successfully addressed the core issues raised by the reviewers.\n\nTo address the evaluation and baseline concerns, the authors provided extensive new experiments. This includes testing against stronger agent-based and test-time baselines, validating the model on an external benchmark (TechImage-Bench), and providing clear RL and reflection ablations. To mitigate the MLLM-as-judge bias, they incorporated an open-source judge (Qwen3.6-27B) and conducted convincing cross-judge and multi-run analyses. Additionally, the authors appropriately agreed to tone down the claims regarding absolute \"reliability\" to better reflect the current system's capabilities.\n\nAlthough one reviewer noted that the method's reliance on unified multimodal models might limit its immediate application to stronger, specialist T2I diffusion models, the general consensus is that the proposed training paradigm and the IlluGenBench resource offer significant value to the community. Given the quality of the original submission and the strong rebuttal, I am glad to recommend this paper for acceptance.",
+ "final_justification": "The authors provided a thorough rebuttal that resolved the main weaknesses identified in the initial reviews. They successfully demonstrated the robustness of their evaluation by adding an open-source judge and external benchmark tests, and they clarified the necessity of their training pipeline through new test-time baseline comparisons and RL ablations. All reviewers are satisfied with the revisions and agree that the proposed framework and the IlluGenBench benchmark are solid contributions to medical image generation."
+ },
+ "createdAt": "2026-09-24T11:16:16.648Z",
+ "modifiedAt": "2026-11-18T14:52:21.843Z",
+ "url": "https://openreview.net/forum?id=RyrXhwjZ2I&noteId=iYADLPjFB8",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ryrxhwjz2i/notes/kz1ivlxwle.json added

+++ b/reviews/openreview/ryrxhwjz2i/notes/kz1ivlxwle.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "kZ1ivLxwle",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer pxiW",
+ "content": {
+ "summary": "The authors propose MedIGen, a text-to-image generation model specifically designed for medical illustrations. The paper argues that visual plausibility does not equate to medical accuracy in this domain. To address this, the authors introduce an interleaved reasoning framework using a \"generate, reflect, refine\" cycle. The model is trained progressively through domain pre-training, supervised fine-tuning on sub-skills, and reinforcement learning. Furthermore, the paper introduces IlluGenBench, a new evaluation benchmark for medical images with fine-grained rubric criteria.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "Strengths:\n\n1. Problem Motivation: The distinction between general visual appeal and strict biomedical validity is highly relevant. The paper identifies a clear gap in existing generative models.\n2. Methodological Design: The multi-stage training pipeline is logical and comprehensive. The iterative refinement process aligns well with the specific nature of medical illustration errors, which are often localized structural inaccuracies rather than global image failures.\n3. Evaluation Resources: IlluGenBench is a substantial contribution to the community. Evaluating scientific accuracy and structural correctness via detailed rubrics is a marked improvement over generic text-image alignment metrics.\n\nWeaknesses:\n\n1. Overstated Claims: The title and abstract use the word \"Reliable\", yet the empirical results show an average score of 0.618 and persistent failures in the disease category. The generation quality is improved but not yet fully reliable for deployment.\n2. Evaluation Methodology Constraints: The benchmark heavily relies on closed-source models for automated judging and data construction. \n3. Statistical Rigor: The main benchmark reports single-run results without confidence intervals. Given the inherent variance in generation and automated evaluation, the stability of marginal performance gains is difficult to verify.\n\nMinor:\nThere are several typographical errors and formatting inconsistencies throughout the manuscript.",
+ "quality": 4,
+ "clarity": 4,
+ "significance": 3,
+ "originality": 3,
+ "questions": "1. A controlled ablation study isolating the causal effect of the reflection text is needed. Comparing the current setup against a baseline that uses multiple generation rounds without the self-reflection step, or one that uses generic feedback, would clarify this contribution.\n2. The representativeness of the long prompts (average 366 words) in IlluGenBench is unclear. Evaluating model performance on a subset of shorter, more realistic user queries would strengthen the benchmark's practical relevance.",
+ "limitations": "Yes.",
+ "rating": 5,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "N/A",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "I maintain my score of 5 (Accept). The authors effectively addressed my main concerns in the rebuttal by providing solid new experiments, including cross-judge analyses, multi-run results, and reflection ablations. Although questions remain about clinical deployment, evaluator bias, and broader domain generalization, the value of IlluGenBench and the rigorous empirical additions justify acceptance."
+ },
+ "createdAt": "2026-06-25T12:14:40.328Z",
+ "modifiedAt": "2026-11-18T13:35:03.538Z",
+ "url": "https://openreview.net/forum?id=RyrXhwjZ2I&noteId=kZ1ivLxwle",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ryrxhwjz2i/notes/p2uf0lpnjy.json added

+++ b/reviews/openreview/ryrxhwjz2i/notes/p2uf0lpnjy.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "P2uF0LpNjy",
+ "replyTo": null,
+ "kind": "meta_review",
+ "invitation": "Meta_Review",
+ "signature": "Area Chair MEfg",
+ "content": {
+ "metareview": "This paper introduces MedIGen, a unified model for medical illustration generation that replaces one-pass synthesis with an interleaved \"generate-reflect-refine\" reasoning process. Key strengths include a well-motivated problem addressing biomedical validity over mere visual plausibility, a comprehensive three-stage training pipeline, and the introduction of IlluGenBench, a rigorous rubric-driven evaluation benchmark. Despite its strong motivation and comprehensive evaluation resources, the reviewers raised several substantial concerns in the initial reviews that needed to be addressed:\n1) Limited novelty: The technical framework combines existing components, such as domain pretraining, generate-reflect-refine cycles, GRPO, and MLLM-based rewards, without introducing sufficiently distinct core methodologies, leading concerns that the work resembles a benchmark or dataset contribution rather than a novel core algorithmic advance. \n2) Potentially biased evaluation: The reliance on MLLM-as-judge frameworks and the authors' internally constructed benchmark introduces potential circularity, alignment biases, and shared vulnerabilities with the proposed generation methodology. \n3) Incomplete evaluation: The empirical study lacks stronger test-time and agent-based baselines, controlled ablations isolating the reflection text, and external validation datasets to prove generalization beyond the proposed benchmark. \n4) Overstated claims: The manuscript repeatedly emphasizes absolute \"reliability,\" yet empirical results reveal persistent failure modes in disease illustrations, limited absolute score gains, and a significant bottleneck where the model frequently fails to correct errors even when they are successfully detected. \n\nI have carefully read the authors' rebuttal and followed the subsequent reviewer discussions. The authors submitted a thorough rebuttal that successfully addressed the core issues raised by the reviewers.\n\nTo address the evaluation and baseline concerns, the authors provided extensive new experiments. This includes testing against stronger agent-based and test-time baselines, validating the model on an external benchmark (TechImage-Bench), and providing clear RL and reflection ablations. To mitigate the MLLM-as-judge bias, they incorporated an open-source judge (Qwen3.6-27B) and conducted convincing cross-judge and multi-run analyses. Additionally, the authors appropriately agreed to tone down the claims regarding absolute \"reliability\" to better reflect the current system's capabilities.\n\nAlthough one reviewer noted that the method's reliance on unified multimodal models might limit its immediate application to stronger, specialist T2I diffusion models, the general consensus is that the proposed training paradigm and the IlluGenBench resource offer significant value to the community. Given the quality of the original submission and the strong rebuttal, I am glad to recommend this paper for acceptance."
+ },
+ "createdAt": "2026-07-21T13:06:29.951Z",
+ "modifiedAt": "2026-11-18T15:18:23.187Z",
+ "url": "https://openreview.net/forum?id=RyrXhwjZ2I&noteId=P2uF0LpNjy",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ryrxhwjz2i/notes/prnqh3nkwx.json added

+++ b/reviews/openreview/ryrxhwjz2i/notes/prnqh3nkwx.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "PrNQh3nKwX",
+ "replyTo": "EZKCJ6YiHf",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "We sincerely appreciate your valuable feedback. Below, we address each concern.\n\n---\n\n> **W1**: authors repeatedly emphasize reliable generation, but performance remains relatively weak on disease illustrations, with the expert audit showing that re-generation overall frequently fails even after successful error detection. Thus, the improvements are relative rather than robust medical correctness guarantees. \n\n**AW1**: We agree that the improvements are relative rather than robust medical correctness guarantees. We will **revise the manuscript** to clearly scope “reliability” to improved biomedical correctness and error correction under the evaluated benchmark settings.\n\n- **Title.** We will revise the wording to emphasize progress toward reliability rather than absolute reliability: *“Toward Reliable Medical Illustration Generation.”*\n- **Abstract/Main text.** We will replace statements that may imply fully reliable generation with more precise comparative wording: *“improves the medical reliability of generated illustrations.”*\n\n---\n\n> **W2 & Q1**: Independent validation on existing medical image-generation benchmarks or broader external evaluation would strengthen confidence in the reported gains.\n\n**AW2&Q1**: We additionally evaluate on the independently constructed **Biology subset of TechImage-Bench [1] (318 tasks, 2,772 criteria)**. We follow its official evaluation and report *Rubric Accuracy* and *Criterion Score*.\n\n|Model|Rubric Accuracy ↑|Criterion Score ↑|\n|-|-:|-:|\n|Janus-Pro-7B|0.548|0.251|\n|Qwen-Image-2512|0.701|0.421|\n|Gemini-3-Pro-Image|**0.849**|**0.625**|\n|**MedIGen**|0.748|0.486|\n\n**Observation.** MedIGen improves substantially over Janus-Pro-7B and remains stronger than Qwen-Image-2512 on both metrics, while Gemini-3-Pro-Image remains the strongest model. This external evaluation shows that **MedIGen's gains generalize beyond IlluGenBench**.\n\n> References\n\n[1] *TechImage-Bench: Rubric-Based Evaluation for Technical Image Generation*\n\n---\n\n> **W3**: The contribution of the RL stage also appears limited in the main benchmark metric (+0.03 absolute improvement). While justified in the appendix, the main paper would benefit from a clearer demonstration that the dual-level reward design itself is necessary.\n\nAnswer: We agree that the improvement from Stage 2 SFT to Stage 3 RL is modest in the main benchmark metric. This is consistent with the intended role of Stage 3: it serves as a final refinement step on top of an already strong Stage-2 model, rather than the primary stage for acquiring medical knowledge.\n\nTo clarify whether the **dual-level reward design** is necessary, we add a controlled ablation. All settings use the same Stage-2 checkpoint, training data, evaluator, and optimization budget. **Image-level RL** uses only generation-quality rewards.\n\n|Setting|Sci. Acc.|Struct. Corr.|Sem. Align.|Avg.|\n|-|-:|-:|-:|-:|\n|No RL|0.5743|0.5082|0.6831|0.5885|\n|Image-level RL|0.5833|0.5152|0.6893|0.5959|\n|Dual-level RL|**0.6064**|**0.5368**|**0.7111**|**0.6183**|\n\n**Observation.** Image-level RL provides only a small gain over no RL (**+0.0074 Avg.**), whereas dual-level RL yields a larger additional improvement (**+0.0224 Avg.**) across all three dimensions. Since the understanding reward is the key additional component, this ablation shows that image-quality optimization alone does not account for the Stage-3 gain.\n\nThe contribution of Stage 3 is also clearer in direct human evaluation. `Figure 8` shows visibly improved medical correctness after RL. In a blinded expert study on the same prompts, the Stage-3 model is preferred in **64%** of cases, compared with **19%** for the Stage-2 model.\n\n|Model A|Model B|A Preferred|Tie|B Preferred|\n|-|-|-:|-:|-:|\n|MedIGen (SFT + RL)|MedIGen (SFT only)|**64%**|17%|19%|\n\nWe further report the **First-Pass Rate**, defined as the fraction of prompts for which the model produces a satisfactory image and correctly accepts it without requiring re-generation. It therefore measures both immediate generation quality and the model’s ability to avoid unnecessary refinement.\n\n|Model|Sci. Acc.|Struct. Corr.|Sem. Align.|Avg.|First-Pass Rate|\n|-|-:|-:|-:|-:|-:|\n|Janus-Pro-7B|0.30|0.22|0.46|0.33|–|\n|MedIGen (SFT)|0.57|0.52|0.68|0.59|**64%**|\n|MedIGen (RL)|0.61|0.54|0.71|0.62|**80%**|\n\n**Observation.** RL increases the First-Pass Rate **from 64% to 80%**, enabling **16%** more prompts to succeed after a single generation without additional re-generation cost. This indicates improved alignment between generation and self-evaluation, with refinement focused on harder cases.\n\nWe will move these results to the main paper to more clearly demonstrate the necessity and practical value of the dual-level reward design.\n\n---\n\n> **W4**: Some other methodological details would also benefit from a stronger discussion, such as quality and diversity of the 150K supervised trajectories.\n\n**AW4**: The 150K samples form a supervised mixture: **(1)** approximately 138K filtered text-to-image samples and **(2)** over 12K generate–reflect–refine trajectories.\n\n**(1) Filtered text-to-image samples (~138K).** These samples are selected from the 1.21M-pair IlluGen-Image corpus through multi-stage filtering for file validity, resolution, source reliability, watermarks, medical relevance, diagrammatic structure, educational value, and overall visual quality.\n\n- **Quality:** A fine-tuned Qwen3-VL-8B performs the medical and visual screening. A subsequent manual audit shows an **approximately 98% acceptability rate**.\n- **Diversity:** The samples cover five major medical illustration categories:\n\n|Category|Proportion|\n|-|-:|\n|Anatomical|37.1%|\n|Educational|23.0%|\n|Disease & Disorder|17.4%|\n|Molecular & Cellular|16.6%|\n|Surgical|4.3%|\n\n**(2) Generate–reflect–refine trajectories (>12K).** The trajectory instructions are constructed from more than **15K MeSH-derived biomedical concepts** and expanded into detailed medical illustration requests. The instructions have a mean length of **273 words** and a median length of **251 words**. Each trajectory contains an initial generation, an image-specific reflection, and a targeted refinement.\n\n- **Quality:** We conduct a stratified audit of **400 trajectories**, with two medical experts independently evaluating the instruction, reflection, and refinement.\n\n|Audit Criterion|Acceptability|\n|-|-:|\n|Medical validity of the instruction|97.3%|\n|Correctness and image grounding of the reflection|94.8%|\n|Specificity and actionability of the correction|95.5%|\n|Consistency between reflection and refinement|93.8%|\n|Overall trajectory acceptability|92.5%|\n\nThe two experts achieve a Cohen’s κ of **0.87**, indicating strong annotation consistency.\n\n- **Diversity:** The trajectories span five medical illustration categories:\n\n|Category|Number of Trajectories|Proportion|\n|-|-:|-:|\n|Anatomical|4,286|34.3%|\n|Educational|2,905|23.3%|\n|Disease & Disorder|2,364|18.9%|\n|Molecular & Cellular|2,072|16.6%|\n|Surgical|853|6.8%|\n|**Total**|**12,480**|**100.0%**|\n\nThe reflections also cover diverse and complementary error types. Because a trajectory may contain multiple errors, these categories are analyzed using multi-label annotation:\n\n|Error Type|Number of Trajectories|Proportion|\n|-|-:|-:|\n|Scientific or medical-content errors|7,086|56.8%|\n|Structural or spatial-relation errors|5,614|45.0%|\n|Semantic or instruction-alignment errors|4,332|34.7%|\n|Multiple error types|3,684|29.5%|\n\nTogether, the 138K text-to-image samples provide broad and high-quality medical visual knowledge, while the 12K+ interleaved trajectories provide diverse process-level supervision for identifying and correcting image-specific medical errors.\n\n**We will incorporate these composition statistics, quality-audit results, diversity analyses, and representative trajectory examples into the revised manuscript.**"
+ },
+ "createdAt": "2026-07-28T12:16:24.630Z",
+ "modifiedAt": "2026-11-18T17:10:50.903Z",
+ "url": "https://openreview.net/forum?id=RyrXhwjZ2I&noteId=PrNQh3nKwX",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ryrxhwjz2i/notes/rv3clfuihy.json added

+++ b/reviews/openreview/ryrxhwjz2i/notes/rv3clfuihy.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "rV3CLFuIHy",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer Xk7f",
+ "content": {
+ "summary": "This paper studies the reliability of the text-to-image generation model for medical images. The author argues that the medical image generation should have reasonable biomedical semantics, spatial relationships, and structural consistency. For this, they introduce MedIGen, coupling generation with self-reflection and regeneration through “generate–reflect–refine” cycles. and a benchmark IlluGenBench with 296 diverse tasks and 9,015 criteria. They test their trained model on several tasks and achieve the best score.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "**Strengths**\n1. The motivation is strong. Medical illustration generation is different from general image generation, since visually plausible images can still be medically wrong.\n2. The paper is comprehensive. It includes a benchmark, domain pretraining, supervised training, and RL-based refinement.\n3. The experiments cover many baselines, including commercial T2I models, open-source T2I models, unified generation models, and reasoning-based models. The reward hacking and cross-evaluator analysis is also useful.\n\n**Weaknesses**\n1. The novelty is limited. All components are based on existing ideas. In my opinion, this paper is better suited for the benchmark and dataset track than the main track.\n2. The paper lacks stronger test-time baselines. I wonder how well simpler agent-based, rethinking-based, or other test-time methods would perform.\n3. The evaluation relies heavily on MLLM judges. This is a dilemma: the paper questions the reliability of existing T2I models, but trusts MLLMs to judge medical correctness. I'm not sure whether this will still be a problem for the T2I model in 1-2 years.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 2,
+ "originality": 2,
+ "questions": "1. Could the authors clarify what they view as the main new technical contribution beyond combining existing components, such as domain pretraining, generate-reflect-refine, GRPO, and MLLM rewards? It would also be helpful to discuss whether simpler approaches, such as prompt optimization, could address part of the problem.\n\n2. Could the authors compare with simple agent-based or test-time baselines and report their performance? This would help clarify whether the proposed training pipeline is necessary.\n\n3. What is the authors' view on this problem in the next 1-2 years? Do they expect current T2I models to continue to suffer from similar medical reliability issues as general image generation models improve?",
+ "limitations": "Yes",
+ "rating": 4,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "No major formatting or anonymity issues noticed.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The rebuttal addresses several of my concerns regarding novelty and evaluation, and I consider IlluGenBench a valuable contribution. However, the method’s restricted applicability to unified models, together with uncertainty about its effectiveness on stronger future T2I backbones, limits its practical significance. Balancing these strengths and limitations, I recommend 4: Borderline Accept."
+ },
+ "createdAt": "2026-06-23T23:46:15.825Z",
+ "modifiedAt": "2026-11-18T13:35:05.024Z",
+ "url": "https://openreview.net/forum?id=RyrXhwjZ2I&noteId=rV3CLFuIHy",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ryrxhwjz2i/notes/wbt1isjslr.json added

+++ b/reviews/openreview/ryrxhwjz2i/notes/wbt1isjslr.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "wbt1ISJSlR",
+ "replyTo": "kZ1ivLxwle",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "We sincerely appreciate your valuable feedback. Below, we address each concern.\n\n---\n\n> **W1: Overstated Claims: The title and abstract use the word \"Reliable\", yet the empirical results show an average score of 0.618 and persistent failures in the disease category. The generation quality is improved but not yet fully reliable for deployment.**\n\n**AW1**: We apologize that some of our wording may have been unclear, and we agree that the current MedIGen should not be interpreted as ready for clinical deployment. Our use of “Reliable” is intended as a *comparative claim*: MedIGen makes medical illustration generation substantially more reliable than conventional one-pass generation by explicitly identifying and correcting medically invalid content, rather than guaranteeing fully reliable generation.\n\nWe will **revise the paper to avoid overstating the claim of “Reliable”**:\n\n- **Title.** We will revise the wording to emphasize progress toward reliability rather than absolute reliability: *“Toward Reliable Medical Illustration Generation.”*\n- **Abstract.** We will replace statements that may imply fully reliable generation with more precise comparative wording: *“improves the medical reliability of generated illustrations.”*\n\n---\n\n> **W2: Evaluation Methodology Constraints: The benchmark heavily relies on closed-source models for automated judging and data construction.**\n\n**AW2**: Closed-source models serve two distinct roles. **(1) Benchmark construction:** they improve the efficiency and scalability of initial drafting, while experts determine the final benchmark. **(2) Automated judging:** they enable scalable criterion-level evaluation, while their reliability is validated through human agreement, cross-judge robustness, and repeated runs.\n\n**(1) Benchmark construction.** GPT-5.1 generates only the initial captions and checklist criteria. Three junior experts review and revise every item, followed by validation by two senior experts. Incorrect, ambiguous, redundant, or unverifiable criteria are revised or removed. IlluGenBench is therefore an **expert-approved benchmark with AI-assisted drafting**, rather than an automatically generated benchmark.\n\nHolding the evaluated images, judge, human annotations, and scoring protocol fixed, expert refinement improves both rubric conciseness and alignment with human judgments:\n\n| Rubric Version | Avg. Criterion Length (words) | Macro-F1 vs. Human |\n|---|---:|---:|\n| Initial MLLM draft | 52.2 | 0.546 |\n| Expert-refined rubric | 30.3 | 0.760 |\n\nThese results confirm that benchmark quality is determined by expert refinement rather than the initial closed-source model output. For reproducibility, we will **directly release the finalized rubrics created with the assistance of closed-source models** after the paper is accepted.\n\n**(2) Automated judging.** Closed-source judges support scalable evaluation, but we do not treat them as ground-truth evaluators. To provide an evaluation pathway independent of proprietary APIs, we additionally introduce **Qwen3.6-27B as an open-source judge** and evaluate all judges through human alignment, cross-judge robustness, and repeated runs.\n\n- **Human alignment.** All three judges align well with expert criterion-level annotations. Gemini-3-Pro achieves the highest Macro-F1, while Qwen3.6-27B provides a competitive open-source alternative.\n\n| Generation Model | GPT-5.1 | Gemini-3-Pro | Qwen3.6-27B |\n|---|---:|---:|---:|\n| Gemini-3-Pro-Image | 0.741 | **0.782** | 0.724 |\n| MedIGen | 0.735 | **0.760** | 0.713 |\n\n- **Cross-judge robustness.** We evaluate the same fixed images and rubrics using the three judges:\n\n| Generation Model | GPT-5.1 | Gemini-3-Pro | Qwen3.6-27B |\n|---|---:|---:|---:|\n| Janus-Pro-7B | 0.3367 | 0.3276 | 0.3662 |\n| Qwen-Image-2512 | 0.5751 | 0.6010 | 0.6238 |\n| Gemini-3-Pro-Image | 0.8564 | 0.8730 | 0.9016 |\n| MedIGen | 0.6354 | 0.6183 | 0.6489 |\n\nQwen3.6-27B produces slightly higher absolute scores, but all judge pairs preserve identical model rankings, with a Spearman correlation of **ρ = 1.000**. Thus, the comparative conclusions are not determined by a particular proprietary judge.\n\n- **Repeated-run stability.** We repeat Qwen3.6-27B judging three times using the same images and rubrics:\n\n| Model | Run 1 | Run 2 | Run 3 | **Mean ± Std.** |\n|---|---:|---:|---:|---:|\n| Janus-Pro-7B | 0.3562 | 0.3835 | 0.3294 | **0.3564 ± 0.0271** |\n| Qwen-Image-2512 | 0.6238 | 0.6521 | 0.5947 | **0.6235 ± 0.0287** |\n| Gemini-3-Pro-Image | 0.8916 | 0.9132 | 0.8678 | **0.8909 ± 0.0227** |\n| MedIGen | 0.6489 | 0.6837 | 0.6145 | **0.6490 ± 0.0346** |\n\nAlthough Qwen3.6-27B shows greater run-to-run variation, the model rankings and comparative conclusions remain unchanged. In our setup, it runs at full precision on a single GPU with **40 GB of VRAM**, enabling automated evaluation without proprietary APIs.\n\n---\n\n> **W3: Statistical Rigor: The main benchmark reports single-run results without confidence intervals. Given the inherent variance in generation and automated evaluation, the stability of marginal performance gains is difficult to verify.**\n\n**AW3**: We agree that single-run results may not adequately characterize the variance introduced by stochastic image generation and automated evaluation. We therefore repeated the complete generation-and-evaluation pipeline **3 times** for MedIGen, Janus-Pro-7B, Qwen-Image-2512, and Gemini-3-Pro-Image. Each run covers all 296 IlluGenBench tasks under identical settings. We report the benchmark scores as *mean ± sample standard deviation*.\n\n| Model | Run 1 | Run 2 | Run 3 | **Mean ± Std.** |\n|---|---:|---:|---:|---:|\n| Janus-Pro-7B | 0.3276 | 0.3428 | 0.3167 | **0.3290 ± 0.0131** |\n| Qwen-Image-2512 | 0.6010 | 0.6112 | 0.5906 | **0.6009 ± 0.0103** |\n| Gemini-3-Pro-Image | 0.8730 | 0.8826 | 0.8654 | **0.8737 ± 0.0086** |\n| MedIGen | 0.6183 | 0.6359 | 0.6011 | **0.6184 ± 0.0174** |\n\n**Observation.** The repeated runs show modest variation, while **the overall model ranking and conclusions remain consistent**. This indicates that the observed performance differences are stable and not driven by a single run. \n\nIn the revised manuscript, we will include these results and extend the stability analysis to additional models and evaluation dimensions.\n\n---\n\n> **W4: Minor: There are several typographical errors and formatting inconsistencies throughout the manuscript.**\n\n**AW4**: Thank you for pointing this out. We will carefully proofread the manuscript and correct all typographical errors and formatting inconsistencies.\n\n- “Evaluation Results of MedGen” → “Evaluation Results of MedIGen” in `Sec. 5.2`.\n- “IlluBenmark Statistics” → “IlluGenBench Statistics” in `Appendix D.1`.\n- “external evaluate” → “external evaluator” in `Sec. 3.2.3`.\n- “0.0.7504” → “0.7504” in `Table 10`.\n\n**These corrections do not affect our methodology, results, or conclusions.**\n\n---\n\n> **Q1: A controlled ablation study isolating the causal effect of the reflection text is needed. Comparing the current setup against a baseline that uses multiple generation rounds without the self-reflection step, or one that uses generic feedback, would clarify this contribution.**\n\n**AQ1**: We agree that the effect of reflection text should be separated from the benefit of repeated generation. We compare three variants using the same checkpoint, three-round generation budget, random seeds, and inference settings; Only the feedback differs:\n\n- **No Reflection**: three generation rounds without feedback.\n- **Generic Feedback**: “*Please improve the image and better follow the prompt.*”\n- **Specific Medical Reflection (Ours)**: image-specific medical, structural, and semantic feedback.\n\n| Method | Sci. Acc. | Struct. Corr. | Sem. Align. | Avg. |\n|---|---:|---:|---:|---:|\n| No Reflection | 0.5795 | 0.5126 | 0.6878 | 0.5899 |\n| Generic Feedback | 0.5581 | 0.4944 | 0.6668 | 0.5724 |\n| **Specific Medical Reflection (Ours)** | **0.6064** | **0.5368** | **0.7111** | **0.6183** |\n\n**Observation.** Specific medical reflection performs best across all dimensions. This demonstrates that the **improvement primarily comes from targeted medical reflection rather than additional generation rounds alone**. \n\nWe will include this controlled ablation in the revised manuscript.\n\n---\n\n> **Q2: The representativeness of the long prompts (average 366 words) in IlluGenBench is unclear. Evaluating model performance on a subset of shorter, more realistic user queries would strengthen the benchmark's practical relevance.**\n\n**AQ2**: We agree that the original IlluGenBench prompts are more detailed than typical user queries. They are designed to specify key medical and structural requirements for controlled evaluation.\n\nTo assess practical relevance, we sample **100 tasks from the five illustration tasks (20 per category)** and rewrite them into concise user-style queries while preserving the core medical intent, reducing the **average prompt length from 366 to 38 words**.\n\n| Model | Full Prompts | Short Queries | **Drop** |\n|---|---:|---:|---:|\n| Janus-Pro-7B | 0.3082 | 0.2578 | **−0.0504** |\n| Qwen-Image-2512 | 0.4627 | 0.4186 | **−0.0441** |\n| Gemini-3-Pro-Image | 0.6785 | 0.6599 | **−0.0186** |\n| MedIGen | 0.5764 | 0.5552 | **−0.0212** |\n\n**Observation.** The results provide three insights. First, shortening prompts causes only moderate degradation while preserving the model ranking (*Spearman ρ = 1.00*), showing that IlluGenBench conclusions are **not driven by prompt verbosity**. Second, concise queries remove explicit anatomical and structural cues, placing more emphasis on **internalized biomedical knowledge**. MedIGen remains relatively robust (*−0.0212*), suggesting that its gains extend beyond detailed specifications to more realistic user-style queries."
+ },
+ "createdAt": "2026-07-28T10:55:08.098Z",
+ "modifiedAt": "2026-11-18T17:10:50.242Z",
+ "url": "https://openreview.net/forum?id=RyrXhwjZ2I&noteId=wbt1ISJSlR",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/ryrxhwjz2i/submission.json added

+++ b/reviews/openreview/ryrxhwjz2i/submission.json
@@ -0,0 +1,12 @@
+{
+ "schema": "submission/1",
+ "id": "RyrXhwjZ2I",
+ "venue": {
+ "id": "NeurIPS.cc/2026/Conference",
+ "name": "NeurIPS 2026",
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"
+ },
+ "number": 1869,
+ "url": "https://openreview.net/forum?id=RyrXhwjZ2I",
+ "license": "CC-BY-4.0"
+}

versions/v_dd8hxsum.json added

+++ b/versions/v_dd8hxsum.json
@@ -0,0 +1,22 @@
+{
+ "date": "2026-04-17",
+ "kind": "submitted",
+ "label": "NeurIPS 2026",
+ "submissions": [
+ {
+ "venue": "NeurIPS 2026",
+ "status": "accepted",
+ "decision": "Accept (poster)",
+ "number": 1869,
+ "url": "https://openreview.net/forum?id=RyrXhwjZ2I",
+ "reviews": "openreview/ryrxhwjz2i",
+ "evidence": [
+ "https://openreview.net/forum?id=RyrXhwjZ2I"
+ ]
+ }
+ ],
+ "url": "https://openreview.net/forum?id=RyrXhwjZ2I",
+ "evidence": [
+ "https://openreview.net/forum?id=RyrXhwjZ2I"
+ ]
+}