potentialpaper

Coarse-to-Fine 3D MRI Reconstruction via Resolution-Agnostic Neural Operators

Update NeurIPS 2026 submission WcGVLtalaf: 20 notes

@openreview[bot] · 2026-11-24 15:52 UTC · 11c28567d5e7 ·

Evidence

reviews/openreview/wcgvltalaf/notes/54bcde2ewr.json added

+++ b/reviews/openreview/wcgvltalaf/notes/54bcde2ewr.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "54BcDe2Ewr",
+ "replyTo": "msIVf6YtyP",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "**MR8. Statistical stability and error bars** *(→ ttAK W3)*. We added 95% confidence intervals, which are **disjoint for all three metrics** across (n = 33) validation volumes. The gains are also consistent across 3 resolutions, 2 anatomies, and 3 acceleration rates.\n\n**MR9. Full computational accounting** *(→ ttAK W4; 92fo W4)*. We rectified the inference comparison to 3.54 versus 2.61 seconds end-to-end. Under a compute-matched comparison, **a quarter-trained KIR-NO outperforms the half-trained CNN** by +2.6 dB **while using 57% less training memory**, a capability unavailable to the fixed-grid CNN.\n\n**MR10. Clinically relevant ROI metrics** *(→ ttAK Q3)*. On the BraTS tumour ROI (n = 251), KIR-NO achieves an SSIM of 0.853 inside the lesion, compared with 0.290 for the CNN. This structural margin is substantially larger than the whole-image difference and is not captured by whole-image averages.\n\n**MR11. Component ablations are already included** *(→ 92fo W3)*. Appendix F includes ablations of the basis function, where piecewise-linear substantially outperforms Morlet, kernel size and radius cutoff, and cascade count. \n\n**Overall.** The acquisition clarification (MR1), the added operator, transformer, and diffusion comparisons in which KIR-NO leads consistently (MR3, MR4), the new robustness, statistical, computational, and clinical evidence (MR2, MR8–MR10), and the previously overlooked ablations (MR11) address the concerns underlying the two rejection ratings without changing the method or its claims. We believe that these comprehensively address all the reviewers’ concerns and also strengthen the empirical support for our conclusions. We respectfully hope that they will be taken into account positively in the reassessment of the submission."
+ },
+ "createdAt": "2026-07-30T03:46:00.560Z",
+ "modifiedAt": "2026-11-19T16:59:57.173Z",
+ "url": "https://openreview.net/forum?id=WcGVLtalaf&noteId=54BcDe2Ewr",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wcgvltalaf/notes/aq9pgmr9ki.json added

+++ b/reviews/openreview/wcgvltalaf/notes/aq9pgmr9ki.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "AQ9PGmR9kI",
+ "replyTo": "VVqe3daHwM",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the reviewer for carefully considering our rebuttal. We address the additional questions below\n\n**A1.**\n\nAll inference experiments were performed on an NVIDIA H200 GPU with 141 GB of memory, which enabled us to generate the complete results reported in Tables 1 and 2. \n\nThe SKM-TEA test set includes volumes acquired using both 8-coil and 16-coil configurations. All peak inference memory values were measured on 8-coil samples, except for KIR-NO at full resolution, which was inadvertently evaluated on 16-coil samples. After rerunning the experiment using 8-coil samples, the peak inference memory for full-resolution KIR-NO on SKM-TEA was **revised to 73.3 GB**. We updated Figure 5 accordingly and clarified that all reported peak inference memory values correspond to 8-coil inference. The updated table is provided below for reference.\n\n**Peak Inference Memory (in GB) (SKM-TEA, 8-coil)**\n\n| Model | Quarter (128×128×80) | Half (256×256×160) | Full SR (512×512×320) |\n| --- | --- | --- | --- |\n| 2D E2E-VarNet | 0.3 | 2.1 | 16.4 |\n| 3D E2E-VarNet | 0.9 | 7.3 | 58.4 |\n| KIR-NO (Ours) | 4.7 | 12.8 | **73.3** |\n\nIn our pipeline for training KIR-NO on quarter-resolution SKM-TEA data, a minor scaling inconsistency caused the training and test datasets to be slightly mismatched. We since corrected the issue and retrained the model, resulting in substantially improved performance. The error was limited to KIR-NO trained on the quarter-resolution SKM-TEA dataset. We carefully rechecked all other results and confirmed that they remain unchanged. In the table below, both models are trained at quarter resolution (128×128×80) and then evaluated at quarter, half and full resolution without any retraining on PSNR/SSIM. **KIR-NO consistently outperforms the CNN baseline at all resolutions**. \n\nWe have updated these numbers in our paper.\n\n| SKM-TEA (trained on quarter) | Quarter (in-domain) | Half (zero-shot) | Full (zero-shot) |\n| --- | --- | --- | --- |\n| 3D E2E-VarNet (CNN) | 27.86 / 0.749 | 31.11 / 0.826 | 33.22 / 0.850 |\n| **KIR-NO (ours)** | **32.32 / 0.878** | **34.06 / 0.980** | **33.66 / 0.996** |\n| Δ | **+4.46 / +0.129** | **+2.95 / +0.154** | **+0.44 / +0.146** |\n\nWe provide the details of an additional experiment we conducted to compare KIR-NO and 3D Varnet training and then performance at quarter and half resolution.\n\nSince our operator is resolution-agnostic, it can be trained at a resolution of 128 × 128 × 80 and directly deployed at 256 × 256 × 160. In contrast, the fixed-grid CNN does not generalize as effectively across resolutions. Both models are evaluated on SKM-TEA at half resolution.\n\n| **Training resolution** | **Quarter 128×128×80** | **Half 256×256×160** |\n| --- | --- | --- |\n| 3D E2E-VarNet (CNN) | 31.11 | 31.44 |\n| **KIR-NO (ours)** | **34.06** | **34.74** |\n\nAt the same resolution, **KIR-NO improves reconstruction quality by 3.3 dB** over the CNN (34.74 vs. 31.44 dB). Halving KIR-NO’s training resolution reduces performance by only 0.68 dB (34.74 to 34.06 dB). **Even at quarter-resolution training, KIR-NO outperforms the half-resolution CNN by 2.6 dB**, while requiring **less time per training step** and **training memory.**\n\n---\n\n**A2**\n\nThe 2D neural operator reconstructs each axial slice independently. Because its DISCO kernels are resolution-agnostic, the model runs natively at each grid resolution.\n\nThe reconstructed slices are then stacked to form a 3D volume, and PSNR is computed over the entire volume using the same procedure as for the 3D methods. Therefore, the reported metrics are volume-wise, not slice-wise.\n\nWe use the same evaluation procedure for the 2D diffusion method: each slice is reconstructed independently, the slices are stacked into a volume, and the metrics are computed over the full volume. We have clarified this methodology in the manuscript accordingly.",
+ "title": "KIR-NO memory, 3D metric, diffusion details (1/2)"
+ },
+ "createdAt": "2026-08-02T07:57:26.168Z",
+ "modifiedAt": "2026-11-19T16:59:57.049Z",
+ "url": "https://openreview.net/forum?id=WcGVLtalaf&noteId=AQ9PGmR9kI",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wcgvltalaf/notes/ayeetuxrbc.json added

+++ b/reviews/openreview/wcgvltalaf/notes/ayeetuxrbc.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "AYEETuxrbC",
+ "replyTo": "VVqe3daHwM",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer 92fo",
+ "content": {
+ "title": "response to authors",
+ "comment": "I appreciate the authors' detailed rebuttal, I have three more questions after reading it:\n1. Judging from Figure 5, training KIR-NO on half-res costs 44GB (which is still substantial), and if I use this model to evaluate on full-res at inference, it would be more than 100GB? Actually, if that is the case, how did the authors report the numbers in Tables 1 and 2? Also, since KIR-NO does not consistently lead in quad-res-to-full-res superresolution, other comparisons could train on even smaller resolutions and still achieve desirable results (comparing Table 1 with 4)\n2. how did the authors evaluate 2D-NO to input 3D volumes for these comparisons, and are the PSNR values computed slice-wise?\n3. the authors claims that the Appendix-E comparison is already matched-budget, i would like to know what is this budget (compute or time or else) and how many steps did the original diffusion models in [33,34] use. Since without specifically tuning the trajectory of diffusion sampling, for a diffusion model trained on thousands of steps, one-step and 11-step sampling would almost certainly land in undesirable results."
+ },
+ "createdAt": "2026-07-31T07:16:47.396Z",
+ "modifiedAt": "2026-11-19T16:59:57.611Z",
+ "url": "https://openreview.net/forum?id=WcGVLtalaf&noteId=AYEETuxrbC",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wcgvltalaf/notes/dc6fonk9ot.json added

+++ b/reviews/openreview/wcgvltalaf/notes/dc6fonk9ot.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "DC6FoNk9ot",
+ "replyTo": "OB71dHUfA7",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer,\n\nThank you for taking the time to review our rebuttal and reconsider your assessment. We appreciate that our clarifications addressed some of your concerns.\n\nCould you please indicate which concerns remain insufficiently addressed, particularly those that are most important to your evaluation? We would be grateful for the opportunity to provide further clarification, additional analysis, or more concrete details about the revisions we plan to make within the discussion period."
+ },
+ "createdAt": "2026-08-02T07:48:39.915Z",
+ "modifiedAt": "2026-11-19T16:59:57.517Z",
+ "url": "https://openreview.net/forum?id=WcGVLtalaf&noteId=DC6FoNk9ot",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wcgvltalaf/notes/eimoic5n2m.json added

+++ b/reviews/openreview/wcgvltalaf/notes/eimoic5n2m.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "eimoiC5n2m",
+ "replyTo": "msIVf6YtyP",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Summarizing Our Responses",
+ "comment": "Dear Area Chair,\n\nWe appreciate the meta-review's concern that fully addressing these points would require more validation than the rebuttal period allows, and we would like to note that the corresponding experiments were completed and submitted within the discussion period. Building on the initial set of experiments we ran for each reviewer, which the meta-review reflects, we document below the further clarifications and experiments we have since provided in response to the reviewers' subsequent questions. \n\n1. **Validation under realistic acquisition settings.** Data is only interpolated in the image domain. KIR-NO trained on quarter resolution performs well even on natively collected full-resolution SKM-TEA data, which shows satisfactory zero-shot generalization. We further report noise and cross-scanner shift experiments and volumetric tumor-ROI metrics\n2. **Memory cost and deployability.** Reviewer 92fo asked whether full-resolution inference was practical. We introduced two exact, output-preserving changes, overlapping patch execution and sequential per-coil data consistency, reducing peak memory for (512×512×320) inference to 22.33 GB with PSNR unchanged at 33.6 dB. This enables full-volume inference on a single 24 GB GPU. In a like-for-like 3D comparison, KIR-NO also requires substantially less memory than Diffusion-3D Physics, 22.33 GB versus 56.5 GB. Diffusion-CSGM uses less memory at 14.5 GB only by reconstructing slices independently, thereby discarding through-plane information and reintroducing precisely the volumetric inconsistency that KIR-NO is designed to address.\n3. **Resolution robustness and corrected quarter-resolution results.** We retrained the quarter-resolution KIR-NO configuration after identifying a split-specific scaling mismatch and verified that all other reported results were unaffected. The corrected model now outperforms every baseline at quarter resolution and under zero-shot transfer to both half and full resolution. At half-resolution evaluation, **quarter-resolution KIR-NO exceeds a 3D E2E-VarNet trained directly at half resolution by 2.6 dB** **while using less time and memory per training step**. Moreover, reducing KIR-NO's own training resolution by half incurs only a 0.68 dB penalty. Together, these results provide direct and compelling evidence for the **resolution robustness** central to the paper. **The Diffusion 3D Baseline metrics are matched by the updated KIR-NO (10 Cascades) result with a lower inference time for our model**.\n4. **Clarification of 2D baseline evaluation.** We clarified that all 2D baseline metrics are computed volume-wise after stacking the reconstructed slices, using exactly the same evaluation procedure as for the 3D methods. The comparison is thus fully consistent and directly comparable across 2D and 3D approaches. \n5. **Baseline fairness and computational trade-offs.** We defined the matched-budget setting precisely and also evaluated both diffusion baselines using their full original sampling trajectories. We report these results transparently, including cases where a baseline achieves higher PSNR. In particular, full-trajectory Diffusion-CSGM exceeds KIR-NO in PSNR but requires 316 s per full-resolution volume, compared with 2.76 s for a single KIR-NO cascade. Our contribution is not maximum PSNR under effectively unbounded inference compute, but resolution-robust, fully volumetric reconstruction that trains at quarter resolution, transfers zero-shot to full resolution, and operates in a single forward pass. The revised timing tables now make this accuracy-efficiency trade-off explicit.\n\nWe are grateful to all reviewers for a constructive discussion that materially strengthened the paper. We believe the rebuttal and additional analyses addressed the substantive concerns raised during review."
+ },
+ "createdAt": "2026-08-04T08:09:09.368Z",
+ "modifiedAt": "2026-11-19T16:59:56.694Z",
+ "url": "https://openreview.net/forum?id=WcGVLtalaf&noteId=eimoiC5n2m",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wcgvltalaf/notes/gerxbwes2i.json added

+++ b/reviews/openreview/wcgvltalaf/notes/gerxbwes2i.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "geRXbweS2i",
+ "replyTo": "B0Leipt1ud",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "**A3**\n\nThe \"matched budget\" refers to matching the number of cascades in our proposed KIR-NO model to the number of inference steps in the diffusion baselines. In the diffusion-based methods each step reinforces the physics and data priors. The proposed KIR-NO is based on an unrolled network with multiple cascades, each of which similarly updates the volume once per cascade by reinforcing the physics and data priors. Hence, we believe that the number of inference steps used by a diffusion-based method is analogous to the number of KIR-NO cascades. We have also tuned the hyperparameters of the diffusion-based methods to ensure a fair comparison.\n\nAs shown in the table below, a single inference step of a diffusion-based method is already more computationally expensive than one KIR-NO cascade. In their original papers, the Diffusion-3D Physics baseline uses 200 steps, while the Diffusion 2D-CSGM baseline uses 1,155 steps. Due to computational constraints, we cannot run KIR-NO for such large number of cascades.\n\n| Method | QR 60 × 60 × 39 | HR 120 × 120 × 78 | FR 240 × 240 × 155 |\n| --- | --- | --- | --- |\n| KIR-NO (single cascade) | 0.091 s | 0.390 s | 2.76 s |\n| Diffusion 3D (single step) | 0.19 s | 0.77 s | 5.46 s |\n| Diffusion 2D (single step) (batched) | 0.13 s | 0.54 s | 3.63 s |\n| **Diffusion 3D (original settings)** | **18.5 s** | **24.5 s** | **70.2 s** |\n| **Diffusion 2D (original settings) (batched)** | **67.9 s** | **110.2 s** | **316.0 s** |\n\nConsequently, matching the number of diffusion steps to the number of KIR-NO cascades does not correspond to a strictly matched computational budget and, in fact, gives the diffusion-based methods a computational advantage. Using their original inference settings would further increase their inference times significantly, making the comparison even more unfairly biased in favor of the diffusion-based methods. \n\nFor completeness, we report the results of the 3D Diffusion baseline using 200 inference steps. The table reproduces Table 5 from the manuscript, with the addition of the new Diffusion–3D Physics row, and includes models evaluated on the quarter- and half-resolution SKM-TEA datasets. We emphasize that this comparison is fundamentally unfair to KIR-NO and is strongly biased in favor of the diffusion baseline: KIR-NO was trained exclusively at quarter resolution, whereas the diffusion model was trained on MRI slices spanning multiple resolutions. The diffusion model therefore benefits from substantially broader training coverage, while KIR-NO is evaluated under a clear distributional disadvantage, particularly at half resolution.\n\n| Method | QR PSNR / SSIM↑ | HR PSNR / SSIM↑ |\n| --- | --- | --- |\n| ***Single Step*** | | |\n| KIR-NO (Ours) | 32.32 / 0.878 | 34.06 / 0.980 |\n| Diffusion-3D Physics | 23.60 / 0.495 | 31.73 / 0.794 |\n| Diffusion-CSGM | 23.49 / 0/434 | 26.20 / 0.518 |\n| ***Multi-step iterative*** | | |\n| Diffusion-3D Physics | 26.68 / 0.590 | 34.42 / 0.830 |\n| **Diffusion-3D Physics (200 steps)** | **35.04 / 0.922** | **38.46 / 0.933** |\n| Diffusion-CSGM | 24.24 / 0.465 | 26.02 / 0.505 |\n| KIR-NO (Ours) | 30.94* / 0.878* | 35.57* / 0.903* |\n\n*As discussed in A1, we identified a minor issue in the quarter-resolution SKM-TEA implementation within the KIR-NO pipeline. Correcting this issue substantially improved the performance of the single-cascade KIR-NO. We will rerun the 10-cascade KIR-NO experiment with the corrected pipeline, and update the table in the revised paper. Based on the gains observed in the single-cascade setting, we anticipate a similar improvement in the performance of KIR-NO in the 10-cascade setting.",
+ "title": "KIR-NO memory, 3D metric, diffusion details (2/2)"
+ },
+ "createdAt": "2026-08-02T07:57:42.580Z",
+ "modifiedAt": "2026-11-19T16:59:56.797Z",
+ "url": "https://openreview.net/forum?id=WcGVLtalaf&noteId=geRXbweS2i",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wcgvltalaf/notes/i02a40gxgc.json added

+++ b/reviews/openreview/wcgvltalaf/notes/i02a40gxgc.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "I02a40gXGC",
+ "replyTo": "B0Leipt1ud",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Thank you again for the detailed discussion, which helped us substantially strengthen the paper. We believe the concerns underlying the original score have now been addressed. We summarize our insightful exchange with the reviewer below:\n\n- Addressed the deployability concern by introducing exact tiled and coil-streamed inference, reducing full-resolution (512×512×320) memory to 22.33 GB on a 24 GB GPU with PSNR unchanged at 33.6 dB\n- Expanded the evaluation with LMO, ReconFormer, the CVPR 2025 2D neural operator, and diffusion baselines under both matched-step and full sampling trajectories.\n- Added and clarified the key ablations, corrected and retrained the quarter-resolution configuration, and showed strong in-domain and zero-shot performance across resolutions. \n- Clarified the volume-wise evaluation of 2D methods. \n\nWe are grateful for the reviewer's engagement. Given that the original concerns and both rounds of follow-up questions have been addressed with new experiments and revisions, **we would be grateful if you could reassess whether the current score of 2 reflects the final state of the paper and discussion.**",
+ "title": "Summary of Discussion with Reviewer 92fo"
+ },
+ "createdAt": "2026-08-03T04:54:09.993Z",
+ "modifiedAt": "2026-11-19T16:59:56.873Z",
+ "url": "https://openreview.net/forum?id=WcGVLtalaf&noteId=I02a40gXGC",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wcgvltalaf/notes/ilmhvjzrhy.json added

+++ b/reviews/openreview/wcgvltalaf/notes/ilmhvjzrhy.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "ILMHVjZrHy",
+ "replyTo": "geRXbweS2i",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Updating KIR-NO 10 Cascades Results",
+ "comment": "Dear Reviewer\n\nIn the **KIR-NO memory, 3D metric, diffusion details (2/2) comment**, we had mentioned that we would re-run the 10 cascade KIR-NO experiment with the corrected pipeline and update the table. We thus provide the updated results for KIR-NO (10 cascades) trained on Quarter Resolution SKM-TEA data:\n\n**Performance:**\n\n| Method | QR PSNR / SSIM↑ | HR PSNR / SSIM↑ |\n| --- | --- | --- |\n| ***Single Step*** | | |\n| Diffusion-3D Physics (Krainovic'24) | 23.60 / 0.495 | 31.73 / 0.794 |\n| Diffusion-CSGM (Jalal'21) | 23.49 / 0/434 | 26.20 / 0.518 |\n| KIR-NO (Ours) (Single cascade) | 32.32 / 0.878 | 34.06 / 0.980 |\n| ***Multi-step iterative*** | | |\n| Diffusion-3D Physics | 26.68 / 0.590 | 34.42 / 0.830 |\n| Diffusion-3D Physics (full sampling) | 35.04 / 0.922 | 38.46 / 0.933 |\n| Diffusion-CSGM | 24.24 / 0.465 | 26.02 / 0.505 |\n| Diffusion-CSGM (full sampling) | 36.88 / 0.936 | 44.47 / 0.983 |\n| **KIR-NO (Ours) (10 cascades)** | **35.92 / 0.936** | **38.20 / 0.996** |\n\n**Computational Efficiency:** While Diffusion-CSGM achieves excellent reconstruction quality when utilizing its full sampling trajectory, we respectfully direct the reviewer's attention to the severe trade-off in inference time required to attain these metrics. As shown in the timing breakdown, KIR-NO provides a highly competitive balance, operating orders of magnitude faster.\n\n| Method | QR 60 × 60 × 39 | HR 120 × 120 × 78 |\n| --- | --- | --- |\n| KIR-NO (single cascade) | 0.091 s | 0.390 s |\n| Diffusion 3D (single step) | 0.19 s | 0.77 s |\n| Diffusion 2D (single step) (batched) | 0.13 s | 0.54 s |\n| Diffusion 3D (original settings) | 18.5 s | 24.5 s |\n| Diffusion 2D (original settings) (batched) | 67.9 s | 110.2 s |\n| **KIR-NO (10 cascades)** | **2.4 s** | **18.0 s** |"
+ },
+ "createdAt": "2026-08-04T07:49:57.269Z",
+ "modifiedAt": "2026-11-19T16:59:56.532Z",
+ "url": "https://openreview.net/forum?id=WcGVLtalaf&noteId=ILMHVjZrHy",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wcgvltalaf/notes/ixdqpaufku.json added

+++ b/reviews/openreview/wcgvltalaf/notes/ixdqpaufku.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "iXDQpAuFku",
+ "replyTo": "k65NncLcNd",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "**W4 — Computational analysis**\n\nWe appreciate this request and extend our computational report.\n\nAt the same resolution, **KIR-NO improves reconstruction quality by 3.3 dB** over the CNN (34.74 vs. 31.44 dB) with only 0.93 s of additional reconstruction time per volume (3.54 vs. 2.61 s), **negligible compared with acquisition times** measured in minutes.\n\nSince our operator is resolution-agnostic, it can be **trained at 128×128×80 and deployed at 256×256×160**, which the fixed-grid CNN cannot do. The table below uses a KIR-NO trained at quarter resolution. The 3D E2E Varnet is trained at half resolution. The models are evaluated on SKM-TEA at half resolution.\n\n| Training resolution | Quarter 128×128×80 | Half 256×256×160 |\n| --- | --- | --- |\n| 3D E2E-VarNet (CNN) | 31.11 | 31.44 |\n| **KIR-NO (ours)** | **34.06** | **34.74** |\n\nHalving KIR-NO’s training resolution reduces performance by only 0.68 dB (34.74 to 34.06 dB). **Even at quarter-resolution training, KIR-NO outperforms the half-resolution CNN by 2.6 dB**, while requiring **less time per training step** and **57% less training memory** (19.8 vs. 45.8 GB).\n\nThe table below shows per-volume model inference cost on a single NVIDIA GH200 GPU for BraTS 8-coil reconstruction at 4x acceleration. Each cell reports model inference time / peak GPU memory. The 2D Diffusion baseline reconstructs slices in batches of 32. The diffusion model was trained using MRI slices across all resolutions.\n\n| Method | QR 60×60×39 | HR 120×120×78 | FR 240×240×155 |\n| --- | --- | --- | --- |\n| VarNet3D CNN (trained on QR) | 0.005 s / 0.12 GiB | 0.013 s / 0.80 GiB | 0.094 s / 6.32 GiB |\n| VarNet3D CNN (trained on HR) | 0.005 s / 0.16 GiB | 0.014 s / 0.90 GiB | 0.095 s / 6.35 GiB |\n| KIR-NO | 0.091 s / 1.28 GiB | 0.390 s / 2.18 GiB | 2.76 s / 8.88 GiB |\n| Diffusion 3D (single step) | 0.19 s / 1.32 GiB | 0.77 s / 3.24 GiB | 5.46 s / 12.99 GiB |\n| Diffusion 3D (multi step) | 1.15 s / 1.58 GiB | 2.31 s / 4.24 GiB | 12.37 s / 18.78 GiB |\n| Diffusion 2D (single step) (batched) | 0.13 s / 0.93 GiB | 0.54 s / 1.61 GiB | 3.63 s / 4.07 GiB |\n| Diffusion 2D (multi step) (batched) | 0.79 s / 0.93 GiB | 2.40 s / 1.65 GiB | 13.06 s / 4.23 GiB |\n\n**W5 — PSNR and SSIM disagreement**\n\nThis is a fair observation, and we believe it reflects a real difference between the metrics rather than an inconsistency in the results. **PSNR and NMSE are global metrics**: they penalize any deviation in absolute intensity. **SSIM is a local, normalized structural metric**. A reconstruction may be structurally faithful yet achieve only modest PSNR, or intensity-accurate yet achieve only modest SSIM. Because these metrics capture complementary aspects of reconstruction quality, we report both alongside NMSE and add this clarification in the manuscript.\n\n**Q2 — BraTS synthetic vs real k-space**\n\nTo clarify, **BraTS uses synthetic k-space data**, not real raw brain measurements. We simulate 8-coil measurements directly from magnitude images using smooth analytic (Biot–Savart-style) sensitivities, which are RSS-normalized.\n\nIn contrast, the **SKM-TEA evaluation uses prospectively acquired raw k-space** from clinical knee qMRI scans. We utilize the multi-coil qDESS data from the SKM-TEA raw-data track, along with the dataset's own JSENSE-estimated sensitivity maps.\n\nThis has been clarified in the manuscript.\n\n**Q3 — ROI metrics / tumour fidelity / measurements beyond PSNR, SSIM, NMSE**\n\nWe agree this is the more clinically meaningful measurement, and we have added tumour-region metrics on BraTS (n = 251) for our method and the 3D CNN.\n\n**The ROI is defined volumetrically**: the set of voxels whose segmentation label is > 0 in the full 3D volume, and not a bounding-box crop or a per-slice 2D region. PSNR and NMSE are evaluated over exactly those voxels; SSIM is a 3D local-window (7×7×7) SSIM map computed over the ROI voxels, so windows at the lesion boundary necessarily include some peritumoral tissue. The metrics are presented in the order: PSNR / SSIM / NMSE.\n\n| Region | **KIR-NO (ours)** | 3D E2E-VarNet (CNN) |\n| --- | --- | --- |\n| Whole image | **36.23 / 0.885 / 0.0217** | 26.58 / 0.757 / 0.2005 |\n| **Tumor ROI** | **29.05 / 0.853 / 0.0170** | 20.26 / 0.290 / 0.1344 |\n\nThe lesion interior is a demanding region in which a non-reconstruction scores essentially zero, so the values in Table reflect genuine differences in lesion structure rather than a metric artifact. \n\nThe results show that\n\n1. **Our normalised error is lower inside the lesion than over the whole image** (0.0170 vs 0.0217), so the diagnostically relevant region is reconstructed at least as faithfully as the rest of the volume.\n2. **The structural margin over the CNN is considerably larger inside the lesion than globally** (SSIM +0.56 in the ROI vs +0.13 whole-image). Our ROI SSIM holds at 0.853 ± 0.038, while the CNN's is 0.290 ± 0.115 — a difference that a whole-image average does not reveal.",
+ "title": "Response to Reviewer ttAK (2/2)"
+ },
+ "createdAt": "2026-07-30T03:33:30.161Z",
+ "modifiedAt": "2026-11-19T16:59:57.074Z",
+ "url": "https://openreview.net/forum?id=WcGVLtalaf&noteId=iXDQpAuFku",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wcgvltalaf/notes/jufmj5j1on.json added

+++ b/reviews/openreview/wcgvltalaf/notes/jufmj5j1on.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "JuFMJ5j1on",
+ "replyTo": "YryRzQawgk",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "**W3 & Q2 — One model for different acceleration rates** \n\nWe clarify that **the same single model is trained once and evaluated zero-shot across different acceleration rates** 4× / 8× / 16×. Only the sampling mask changes at test time; the model weights are fixed, and no retraining or fine-tuning is performed per acceleration rate. We make this clearer and more explicit in the protocol description.\n\n**W4 & Q1 — Novelty compared to 2D neural-operator MRI** \n\nThe novelty is not \"a neural operator for MRI\", since the cited works already achieve this, but rather **making resolution-agnostic reconstruction work natively in 3D, driven by a problem the 2D line cannot address.** The methods the reviewer cites (*\"A Unified Model for CS-MRI Across Undersampling Patterns\"* and LMO) are 2D and slice-wise, and study multi-resolution/robustness in the 2D setting. Our contribution is distinct along three axes.\n\n**(a) Problem-driven: native 3D, not 2D slice-by-slice.** Clinically, volumetric acquisitions should be reconstructed as volumes, as slice-wise stacking discards through-plane consistency and fidelity which matter for lesions that span slices. However, native 3D reconstruction faces a significant practical barrier that 2D methods do not: training memory scales as $O(n^3)$, making full-volume back-propagation infeasible at clinical resolution. KIR-NO removes this barrier via its **coarse-to-fine** paradigm: train where back-propagation is feasible (low resolution), and deploy zero-shot at the desired high resolution. The prior 2D E2E neural-operator paper instead focuses on multi-resolution results in 2D and does not confront the 3D memory problem.\n\n**(b) New technique: native 3D DISCO and 3D filters.** Resolution-agnostic 3D reconstruction requires machinery that does not exist in 2D DISCO. We design **native 3D continuous kernel bases** — piecewise-linear hat functions in spherical coordinates and a 3D Morlet basis — that are strictly local, **anisotropy-aware** (3D MRI is anisotropic), and memory-feasible on volumetric grids; a naive Cartesian 2D→3D basis is cubic in basis functions per kernel and untenable. Combined with a **3D k-space operator head**, this is what enables coarse-to-fine 3D reconstruction. It is a new construction, not a re-parameterization of the 2D method.\n\n**(c) Generality beyond MRI.** The result is a **general resolution-agnostic 3D architecture**, not an MRI-specific trick: the same 3D DISCO construction applies to other volumetric inverse problems and 3D imaging modalities (e.g., photoacoustic/CT-style tomography, 3D microscopy), where the low-resolution-train / high-resolution-deploy regime can be a natural and practical extension of the proposed method.\n\nWe now cite and discuss both works explicitly and position our contribution against them along these three axes more explicitly in the related-work section.",
+ "title": "Response to Reviewer KU44 (2/2)"
+ },
+ "createdAt": "2026-07-30T03:25:22.842Z",
+ "modifiedAt": "2026-11-19T16:59:57.163Z",
+ "url": "https://openreview.net/forum?id=WcGVLtalaf&noteId=JuFMJ5j1on",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wcgvltalaf/notes/mgg77nes9b.json added

+++ b/reviews/openreview/wcgvltalaf/notes/mgg77nes9b.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "Mgg77nes9B",
+ "replyTo": "OB71dHUfA7",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer KU44",
+ "content": {
+ "title": "response to authors",
+ "comment": "I thank the authors for their clarification and detailed response, which partially addressed my concerns. I have updated my score accordingly."
+ },
+ "createdAt": "2026-08-01T14:12:48.239Z",
+ "modifiedAt": "2026-11-19T16:59:57.215Z",
+ "url": "https://openreview.net/forum?id=WcGVLtalaf&noteId=Mgg77nes9B",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wcgvltalaf/notes/msivf6ytyp.json modified

+++ b/reviews/openreview/wcgvltalaf/notes/msivf6ytyp.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair sWyu",
"content": {
- "metareview": "Thank you for submitting this paper. The reviewers generally agree that addressing memory-efficient 3D MRI reconstruction through low-resolution training and high-resolution inference is an important and practically relevant problem. The combination of neural operators with an unrolled MRI reconstruction framework was viewed as a technically reasonable approach, and the reported improvements over the E2E-VarNet baselines suggest promising potential. At the same time, the reviewers raised several significant concerns regarding the experimental methodology and the extent to which the current empirical evidence supports the paper’s central claims. The comments below summarize the major discussion points rather than providing an exhaustive list. Addressing these concerns would substantially strengthen the work.\n\n* The experimental protocol requires stronger validation under realistic MRI acquisition settings. Multiple reviewers considered this to be the primary weakness of the paper. In particular, the proposed cross-resolution setting is based on downsampling and interpolation of MRI data, which may alter the underlying k-space frequency structure and therefore may not faithfully represent genuine high-resolution acquisition. As a result, the reviewers felt that the current experiments do not sufficiently establish that the reported gains would translate to realistic clinical settings.\n* The experimental comparisons and positioning should be strengthened. Several reviewers noted that the empirical evaluation omits a number of recent MRI reconstruction approaches, including transformer-, state-space-, diffusion-, and neural-operator-based methods. In particular, reviewers questioned how the proposed method differs from and improves upon recent neural-operator MRI reconstruction frameworks that also study robustness across resolutions or undersampling patterns. A clearer positioning with more comprehensive comparisons would better establish the novelty and practical significance of the work.\n* Several important aspects of the experimental protocol require clarification. The reviewers requested clarification regarding the training strategy across acceleration rates, specifically whether a single model generalizes across sampling rates or separate models are trained for each setting. Additional details regarding the evaluation protocol, particularly the construction of the high-resolution experiments and the use of synthetic versus real raw k-space data, would improve reproducibility and interpretation of the reported results.\n* Additional analyses would strengthen the empirical evidence. The reviewers requested broader evaluations, including computational efficiency (e.g., parameter count, memory consumption, training and inference cost), statistical stability across multiple runs, clinically relevant evaluation metrics beyond PSNR/SSIM/NMSE, and more comprehensive ablations of the proposed architectural components. These analyses would help better understand both the practical advantages and the limitations of the proposed framework.\n\nOverall, the reviewers recognize the practical importance of improving memory-efficient 3D MRI reconstruction and view the proposed framework as an interesting application of neural operators to this setting. However, the current experimental evidence does not yet convincingly support several of the paper’s central claims, particularly regarding zero-shot high-resolution generalization and practical applicability under realistic acquisition scenarios. Addressing these concerns would likely require more substantial experimental validation, broader comparisons with recent methods, and a clearer characterization of the method’s capabilities than can reasonably be expected during the rebuttal period. The reviewers’ comments therefore provide constructive guidance for strengthening a future version of the work."
+ "metareview": "Thank you for submitting this paper. The reviewers generally agree that addressing memory-efficient 3D MRI reconstruction through low-resolution training and high-resolution inference is an important and practically relevant problem. The combination of neural operators with an unrolled MRI reconstruction framework was viewed as a technically reasonable approach, and the reported improvements over the E2E-VarNet baselines suggest promising potential. At the same time, the reviewers raised several significant concerns regarding the experimental methodology and the extent to which the current empirical evidence supports the paper’s central claims. The comments below summarize the major discussion points rather than providing an exhaustive list. Addressing these concerns would substantially strengthen the work.\n\n* The experimental protocol requires stronger validation under realistic MRI acquisition settings. Multiple reviewers considered this to be the primary weakness of the paper. In particular, the proposed cross-resolution setting is based on downsampling and interpolation of MRI data, which may alter the underlying k-space frequency structure and therefore may not faithfully represent genuine high-resolution acquisition. As a result, the reviewers felt that the current experiments do not sufficiently establish that the reported gains would translate to realistic clinical settings.\n* The experimental comparisons and positioning should be strengthened. Several reviewers noted that the empirical evaluation omits a number of recent MRI reconstruction approaches, including transformer-, state-space-, diffusion-, and neural-operator-based methods. In particular, reviewers questioned how the proposed method differs from and improves upon recent neural-operator MRI reconstruction frameworks that also study robustness across resolutions or undersampling patterns. A clearer positioning with more comprehensive comparisons would better establish the novelty and practical significance of the work.\n* Several important aspects of the experimental protocol require clarification. The reviewers requested clarification regarding the training strategy across acceleration rates, specifically whether a single model generalizes across sampling rates or separate models are trained for each setting. Additional details regarding the evaluation protocol, particularly the construction of the high-resolution experiments and the use of synthetic versus real raw k-space data, would improve reproducibility and interpretation of the reported results.\n* Additional analyses would strengthen the empirical evidence. The reviewers requested broader evaluations, including computational efficiency (e.g., parameter count, memory consumption, training and inference cost), statistical stability across multiple runs, clinically relevant evaluation metrics beyond PSNR/SSIM/NMSE, and more comprehensive ablations of the proposed architectural components. These analyses would help better understand both the practical advantages and the limitations of the proposed framework.\n\nOverall, the reviewers recognize the practical importance of improving memory-efficient 3D MRI reconstruction and view the proposed framework as an interesting application of neural operators to this setting. However, the current experimental evidence does not yet convincingly support several of the paper’s central claims, particularly regarding zero-shot high-resolution generalization and practical applicability under realistic acquisition scenarios. Addressing these concerns would likely require more substantial experimental validation, broader comparisons with recent methods, and a clearer characterization of the method’s capabilities than can reasonably be expected during the rebuttal period. The reviewers’ comments therefore provide constructive guidance for strengthening a future version of the work.",
+ "final_justification": "Taking into account the rebuttal and subsequent discussion, I believe the authors have addressed most of the major empirical and methodological concerns raised in the initial reviews. In particular, they clarified the cross-resolution acquisition protocol and acceleration-rate setting, added comparisons with recent transformer-, neural-operator-, and diffusion-based baselines, provided robustness and clinically relevant evaluations, expanded computational and memory analyses, and demonstrated full-resolution inference within a 24 GB GPU budget. These additions substantially strengthen the empirical support for the paper’s central claims.\n\nThe main remaining concern is the degree of method-specific novelty, as noted by Reviewer KU44: coarse-to-fine resolution transfer is partly an inherent benefit of neural operators. Nevertheless, the native 3D operator construction, volumetric reconstruction framework, and practical treatment of the memory bottleneck constitute meaningful contributions beyond prior 2D/slice-wise approaches. Given that the major experimental concerns underlying the initial negative assessments were substantially resolved during discussion, I view the final version more favorably than reflected in my initial meta-review and recommend acceptance."
},
"createdAt": "2026-07-22T14:51:56.662Z",
- "modifiedAt": "2026-11-18T15:18:24.018Z",
+ "modifiedAt": "2026-11-19T04:59:06.536Z",
"url": "https://openreview.net/forum?id=WcGVLtalaf&noteId=msIVf6YtyP",
"license": "CC-BY-4.0"
}

reviews/openreview/wcgvltalaf/notes/ob71dhufa7.json added

+++ b/reviews/openreview/wcgvltalaf/notes/ob71dhufa7.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "OB71dHUfA7",
+ "replyTo": "k65NncLcNd",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the reviewer for the thorough and constructive review. We address each point below.\n\n**W1 & Q1 — Qualifying the zero-shot full-resolution claim**\n\nWe agree this needs a precise statement. On SKM-TEA the full-resolution target is 512×512×320, and the in-plane 512×512 grid is **natively acquired**. Our model is trained at half resolution (256×256×160) and **evaluated at full resolution zero-shot**, with fixed weights. Going from 256 to 512 in-plane requires the operator to recover **genuinely measured** high-frequency content on a grid it never saw during training, rather than content introduced by an upsampling step.\n\nWe also clarify that **no k-space data is ever interpolated directly.** Lower-resolution volumes are **resized in image space** and the k-space data is then obtained by FFT of that resized image. The k-space data at each resolution is thus the exact transform of a clean image on that grid. We rectify and clarify both the claim and this pipeline in the revision.\n\n**W2 — Robustness under realistic shifts**\n\nWe appreciate the insightful suggestion, and conducted two additional experiments, now included in the manuscript, to explore robustness.\n\n**(a) Measurement noise.** We inject Additive White Gaussian Noise in the sampled k-space positions at a controlled Signal to Noise ratio. The KIR-NO model as well as 3D E2E Varnet were trained on half-resolution SKM-Tea data and lightly fine-tuned on noisy data for the final 8 epochs. They are both evaluated on noisy half resolution SKM-Tea data on PSNR. **KIR-NO leads the CNN baseline at every noise level**.\n\n| Measurement SNR (dB) | No noise | 20 | 14 | 8 |\n| --- | --- | --- | --- | --- |\n| **KIR-NO (noise-aware)** | **34.74** | **34.54** | **34.00** | **32.24** |\n| 3D E2E-VarNet CNN (noise-aware) | 31.44 | 31.65 | 31.37 | 30.34 |\n| Δ | +3.3 | +2.9 | +2.6 | +1.9 |\n\n**(b) Cross-scanner transfer (SKM-TEA → fastMRI knee).** \n\ni) We test on a different acquisition: models trained on SKM-TEA at quarter resolution and applied to fastMRI knee, which differs in scanner, coil array, protocol and SNR. Both models were trained on the quarter resolution SKM-TEA dataset. In the few shot case, both models were fine-tuned for 15 epochs on 2 FastMRI Knee volumes. The results below are based on evaluation on unseen 33 FastMRI whole Knee Volumes.\n\n| Evaluation on fastMRI knee | PSNR/SSIM (zero-shot) | PSNR/SSIM (few-shot) |\n| --- | --- | --- |\n| 3D E2E-VarNet (CNN) | 20.89 / 0.485 | 23.15 / 0.573 |\n| KIR-NO (ours) | **24.04 / 0.617** | **27.05 / 0.730** |\n| Δ | +3.15 / +0.132 | +3.90 / +0.157 |\n\n**KIR-NO adapts well** (and better than the VarNet) from an already high zero-shot number, reaching a usable reconstruction on a new scanner from very little target data. We note as well that the gap between the VarNet and the KIR-NO increases with light fine-tuning.\n\nii) We test on resolution changes: both models are trained at quarter resolution (128×128×80) and then evaluated at quarter, half and full resolution without any retraining on PSNR/SSIM. **KIR-NO consistently outperforms the CNN baseline at all resolutions**.\n\n| SKM-TEA (trained on quarter) | Quarter (in-domain) | Half (zero-shot) | Full (zero-shot) |\n| --- | --- | --- | --- |\n| 3D E2E-VarNet (CNN) | 27.86 / 0.749 | 31.11 / 0.826 | 33.22 / 0.850 |\n| **KIR-NO (ours)** | **32.32 / 0.878** | **34.06 / 0.980** | **33.66 / 0.996** |\n| Δ | **+4.46 / +0.129** | **+2.95 / +0.154** | **+0.44 / +0.146** |\n\n**W3 — Error bars on multiple runs**\n\nWe thank the reviewer for this suggestion. We now report variability and confidence intervals across all (n=33) validation volumes from SKM-TEA under the half-resolution, (4\\times) setting, with both training and evaluation performed at half resolution. Results are presented as the mean (\\pm) standard deviation across volumes, followed in brackets by the two-sided 95% confidence interval for the mean in (t₃₂)\n\n| Metric | **KIR-NO (ours)** | 3D E2E-VarNet (CNN) |\n| --- | --- | --- |\n| PSNR (dB) ↑ | **34.74 ± 1.60** [34.17, 35.31] | 31.44 ± 1.67 [30.85, 32.03] |\n| SSIM ↑ | **0.888 ± 0.023** [0.880, 0.896] | 0.824 ± 0.038 [0.810, 0.838] |\n| NMSE ↓ | **0.023 ± 0.007** [0.0205, 0.0255] | 0.043 ± 0.013 [0.0384, 0.0476] |\n\nThe confidence intervals are **disjoint on all three metrics**.",
+ "title": "Response to Reviewer ttAK (1/2)"
+ },
+ "createdAt": "2026-07-30T03:30:31.984Z",
+ "modifiedAt": "2026-11-19T16:59:57.148Z",
+ "url": "https://openreview.net/forum?id=WcGVLtalaf&noteId=OB71dHUfA7",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wcgvltalaf/notes/slaogmz4wa.json added

+++ b/reviews/openreview/wcgvltalaf/notes/slaogmz4wa.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "SlAOGMz4WA",
+ "replyTo": "VyzWEbqRml",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Inference under 24GB and diffusion memory & clarifications",
+ "comment": "We thank the reviewer for carefully considering our response. We address the additional questions below.\n\n**A1**\n\nWe thank the reviewer for this question that encourages us to refine the implementation to reduce memory costs. While our core contribution fundamentally resolves prohibitive memory costs during **training** via our coarse-to-fine approach, we confirm that inference can indeed be performed on a 24 GB GPU without any loss in PSNR.\n\nThe initial 73.3 GB peak memory footprint arises from materializing the entire volume's feature maps and all multi-coil buffers simultaneously. By trading runtime for memory, we introduce two arithmetically exact modifications that fit the 512×512×320 volume inference within 24 GB:\n\n- **Tiled Execution:** Because KIR-NO's DISCO cascades are strictly local, the volume can be processed in overlapping 3D windows. By padding the tiles with a halo, the output remains identical to a whole-volume forward pass.\n- **Sequential Coil Streamed Data Consistency (DC):** The k-space DC and FFT operations are computed globally but streamed one coil at a time, reducing the peak memory footprint from 8/16 coils to a single coil.\n\nBecause both strategies are arithmetically exact, the PSNR is preserved perfectly at the cost of longer inference times due to sequential passes and halo recomputations. While FP16 precision could reduce memory further, we maintain FP32 for this analysis to avoid introducing negligible rounding differences.\n\nImplementing these changes reduces KIR-NO's peak inference memory on the full-resolution SKM-TEA dataset to **22.33 GB**, leaving the Mean Full Resolution Reconstruction **PSNR unchanged** at 33.6 dB. The resulting inference time is 87.3 seconds. We will detail this deployment mode in Appendix C.\n\n---\n\n**A2**\n\nPeak Inference Memory for Diffusion Model Baselines on SKM-TEA Full Resolution\n\n| Method | Peak Inference Memory (GB) |\n| --- | --- |\n| KIR-NO (Ours) | 73.3 |\n| Diffusion-3D Physics | 56.5 |\n| Diffusion-CSGM | 14.5 |\n| KIR-NO (tiled+coil-streamed) | 22.33 |\n\nThe appropriate like-for-like comparison is 3D versus 3D. KIR-NO is less computationally expensive than 3D diffusion and requires only a single forward pass. Although 2D slice-wise diffusion uses less memory, it does so by processing slices independently rather than forming a coherent 3D volume. This introduces precisely the through-plane inconsistency that the paper aims to address, as discussed in Section 1. In tiled mode, KIR-NO achieves memory usage compatible with commodity GPUs while preserving fully volumetric processing.\n\n---\n\n**A3**\n\nYes, the updated metrics for Diffusion-CSGM under the 'Original Setting' reflect its full sampling trajectory. We apologize for their absence in our previous response; these full-trajectory experiments were still computing at the time and have now concluded. The finalized values are included in the updated table below.\n\n| Method | QR PSNR / SSIM↑ | HR PSNR / SSIM↑ |\n| --- | --- | --- |\n| ***Single Step*** | | |\n| KIR-NO (Ours) | 32.32 / 0.878 | 34.06 / 0.980 |\n| Diffusion-3D Physics | 23.60 / 0.495 | 31.73 / 0.794 |\n| Diffusion-CSGM | 23.49 / 0/434 | 26.20 / 0.518 |\n| ***Multi-step iterative*** | | |\n| Diffusion-3D Physics | 26.68 / 0.590 | 34.42 / 0.830 |\n| **Diffusion-3D Physics (Original Setting)** | **35.04 / 0.922** | **38.46 / 0.933** |\n| Diffusion-CSGM | 24.24 / 0.465 | 26.02 / 0.505 |\n| **Diffusion-CSGM (Original Setting)** | **36.88 / 0.936** | **44.47 / 0.983** |\n| KIR-NO (Ours) | 30.94* / 0.878* | 35.57* / 0.903* |\n\nWhile Diffusion-CSGM achieves excellent reconstruction quality when utilizing its full sampling trajectory, we respectfully direct the reviewer's attention to the severe trade-off in inference time required to attain these metrics. As shown in the timing breakdown, KIR-NO provides a highly competitive balance, operating orders of magnitude faster.\n\n| Method | QR 60 × 60 × 39 | HR 120 × 120 × 78 | FR 240 × 240 × 155 |\n| --- | --- | --- | --- |\n| KIR-NO (single cascade) | 0.091 s | 0.390 s | 2.76 s |\n| Diffusion 3D (single step) | 0.19 s | 0.77 s | 5.46 s |\n| Diffusion 2D (single step) (batched) | 0.13 s | 0.54 s | 3.63 s |\n| **Diffusion 3D (original settings)** | **18.5 s** | **24.5 s** | **70.2 s** |\n| **Diffusion 2D (original settings) (batched)** | **67.9 s** | **110.2 s** | **316.0 s** |"
+ },
+ "createdAt": "2026-08-03T18:33:54.526Z",
+ "modifiedAt": "2026-11-19T16:59:56.531Z",
+ "url": "https://openreview.net/forum?id=WcGVLtalaf&noteId=SlAOGMz4WA",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wcgvltalaf/notes/ujyhee68yl.json added

+++ b/reviews/openreview/wcgvltalaf/notes/ujyhee68yl.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "uJYhee68Yl",
+ "replyTo": "YryRzQawgk",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the reviewer for their careful and detailed review, and in particular for the concrete pointers to recent work, which helped us strengthen the empirical comparison. We address each point below.\n\n**W1 & Q3 — Does resizing disturb the k-space structure?**\n\nWe welcome the opportunity to provide further clarification on the data pipeline, and refine the description in the paper accordingly. **We never manipulate or interpolate k-space data directly.** There was an unfortunate typo in line 300 of our manuscript (now removed), and we reiterate that **there is no interpolation in k-space at any stage.** \n\nFor each target resolution we (i) resize the volume in image space, (ii) transform to k-space by taking the FFT of that resized image, and (iii) apply the undersampling mask. The k-space data at every resolution is thus the **exact transform of a clean image on that grid**, not an interpolated spectrum. Interpolating in k-space would indeed introduce the artifacts the reviewer describes, which is precisely why we avoid it; the image-space protocol we use is the standard one in accelerated MRI, including the 2D E2E-VarNet line of work. We apologize for the typo and corrected the manuscript.\n\nWe also note that *no public 3D MRI dataset provides the same anatomy acquired at multiple output resolutions*, as scanning the same living subject repeatedly at varying resolutions is costly and time-consuming, creates strict hardware limits across scanner strengths, and introduces motion and biological changes over time. Thus, a cross-resolution protocol has to be constructed rather than acquired. Additionally, on SKM-TEA, the full-resolution target is 512 × 512 × 320, and the in-plane 512 × 512 grid is natively acquired. Evaluating a half-resolution-trained model there thus requires the operator to recover genuinely measured high-frequency content on a grid it never saw during training, rather than content synthesized by an upsampling step. \n\nWe will state and clarify this pipeline more explicitly in the experimental-setup section.\n\n**W2 — Comparison to new baselines (LMO, ReconFormer, 2D-NO)**\n\nWe thank the reviewer for the references, and added both baselines to our evaluation. To ensure a direct and fair comparison, all models (LMO, ReconFormer, 2D-NO and our KIR-NO) are **trained once at quarter resolution** (128 × 128 × 80) and evaluated across all three grids with the same fixed weights.\n\nLMO is a 2D, fixed-grid (128²) method and is competitive on its native grid; it is evaluated on the higher-resolution grids for completeness. ReconFormer and KIR-NO are evaluated on the half and full grids in a zero-shot manner, having never seen samples at these resolutions during training.\n\nThe table below shows the PSNR (dB) comparison:\n\n| Evaluated at | LMO (CVPR'25) | ReconFormer | 2D-NO | KIR-NO (ours) |\n| --- | --- | --- | --- | --- |\n| **Quarter** 128 × 128 × 80 (in-domain) | 28.89 | 30.67 | 27.13 | **32.32** |\n| **Half** 256 × 256 × 160 (zero-shot) | 26.95 | 32.74 | 20.72 | **34.06** |\n| **Full** 512 × 512 × 320 (zero-shot) | 26.48 | 33.08 | 20.57 | **33.66** |\n\n**KIR-NO consistently outperforms all baselines across all resolutions**. Notably, at the half-resolution target (256 × 256 × 160), our method achieves 34.06 dB while training at only quarter resolution, yielding a +1.3 dB improvement over ReconFormer and a +7.1 dB improvement over LMO. We include this table in the revised manuscript.**W3 & Q2 — One model for different acceleration rates** \n\nWe clarify that **the same single model is trained once and evaluated zero-shot across different acceleration rates** 4× / 8× / 16×. Only the sampling mask changes at test time; the model weights are fixed, and no retraining or fine-tuning is performed per acceleration rate. We make this clearer and more explicit in the protocol description.",
+ "title": "Response to Reviewer KU44 (1/2)"
+ },
+ "createdAt": "2026-07-30T03:22:59.981Z",
+ "modifiedAt": "2026-11-19T16:59:57.172Z",
+ "url": "https://openreview.net/forum?id=WcGVLtalaf&noteId=uJYhee68Yl",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wcgvltalaf/notes/vvqe3dahwm.json added

+++ b/reviews/openreview/wcgvltalaf/notes/vvqe3dahwm.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "VVqe3daHwM",
+ "replyTo": "B0Leipt1ud",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the reviewer for their review, which we believe identifies a genuine gap in how we presented the comparisons, and we address each point below.\n\n**W1 — Comparison limited to CNN baselines**\nWe agree that the baseline coverage should extend beyond CNNs, and added three non-CNN baselines below. Each model has been trained at quarter resolution SKM-TEA data and is evaluated across SKM-TEA across resolutions.\n\n| Evaluated at | LMO (CVPR'25) | ReconFormer | 2D-NO (CVPR’25) | KIR-NO (ours) |\n| --- | --- | --- | --- | --- |\n| Quarter 128 × 128 × 80 (in-domain) | 28.89 | 30.67 | 27.13 | **32.32** |\n| Half 256 × 256 × 160 (zero-shot) | 26.95 | 32.74 | 20.72 | **34.06** |\n| Full 512 × 512 × 320 (zero-shot) | 26.48 | 33.08 | 20.57 | **33.66** |\n\nRegarding diffusion baselines: the Appendix-E comparison is already **matched-budget**, not a single constrained setting. We evaluate both a single-step regime (one forward pass / one sampling step) and an 11-step regime (equal step count for both methods); KIR-NO leads in both, by **+2.5 dB over Diffusion-3D-Physics** (Krainovic'24) and **+8.0 dB over Diffusion-CSGM** (Jalal'21) at a single step on half resolution. Notably, the diffusion models were trained on MRI slices spanning all resolutions, which gives them a substantial advantage over KIR-NO. Nevertheless, KIR-NO still achieves the strongest performance.\n\nWe additionally report the diffusion baselines' peak inference memory and latency:\n\n| Method | QR 60 × 60 × 39 | HR 120 × 120 × 78 | FR 240 × 240 × 155 |\n| --- | --- | --- | --- |\n| VarNet3D CNN (trained on QR) | 0.005 s / 0.12 GiB | 0.013 s / 0.80 GiB | 0.094 s / 6.32 GiB |\n| VarNet3D CNN (trained on HR) | 0.005 s / 0.16 GiB | 0.014 s / 0.90 GiB | 0.095 s / 6.35 GiB |\n| KIR-NO | 0.091 s / 1.28 GiB | 0.390 s / 2.18 GiB | 2.76 s / 8.88 GiB |\n| Diffusion 3D (single step) | 0.19 s / 1.32 GiB | 0.77 s / 3.24 GiB | 5.46 s / 12.99 GiB |\n| Diffusion 3D (multi step) | 1.15 s / 1.58 GiB | 2.31 s / 4.24 GiB | 12.37 s / 18.78 GiB |\n| Diffusion 2D (single step) (batched) | 0.13 s / 0.93 GiB | 0.54 s / 1.61 GiB | 3.63 s / 4.07 GiB |\n| Diffusion 2D (multi step) (batched) | 0.79 s / 0.93 GiB | 2.40 s / 1.65 GiB | 13.06 s / 4.23 GiB |\n\n**W2 — Missing comparison with \"A Unified Model for CS-MRI Across Undersampling Patterns\" (2D-NO)**\n\nWe thank the reviewer for mentioning this work, currently cited and discussed in our manuscript. The referenced method operates in 2D and reconstructs volumes slice by slice, whereas KIR-NO addresses the native 3D reconstruction problem through memory-efficient volumetric processing. This distinction allows KIR-NO to leverage through-plane structure that is unavailable to slice-wise methods. We showed the comparison with the 2D-NO model earlier, and now extend and clarify this positioning in the related-work section.",
+ "title": "Response to Reviewer 92fo (1/2)"
+ },
+ "createdAt": "2026-07-30T03:34:58.435Z",
+ "modifiedAt": "2026-11-19T16:59:57.071Z",
+ "url": "https://openreview.net/forum?id=WcGVLtalaf&noteId=VVqe3daHwM",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wcgvltalaf/notes/vyzwebqrml.json added

+++ b/reviews/openreview/wcgvltalaf/notes/vyzwebqrml.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "VyzWEbqRml",
+ "replyTo": "VVqe3daHwM",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer 92fo",
+ "content": {
+ "title": "Response to authors",
+ "comment": "Thanks for the detailed rebuttal. I am still concerned since the cost for training/inference is still alarmingly high, could the authors provide a surrogate so that full-res volumes with axial resolution at 512x512 can also be inferenced on common GPUs, like a NVIDIA RTX 4090 with 24GB VRAM? how would that surrogate perform on PSNR? And also, what is the inference memory cost for 2D/3D diffusion models on 512x512 axial resolutions? Does Diffusion-CSGM reported in A3 Tab2 under multi-step iterative use full sampling trajectory?"
+ },
+ "createdAt": "2026-08-02T11:35:28.750Z",
+ "modifiedAt": "2026-11-19T16:59:56.694Z",
+ "url": "https://openreview.net/forum?id=WcGVLtalaf&noteId=VyzWEbqRml",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wcgvltalaf/notes/wrhvxsezas.json added

+++ b/reviews/openreview/wcgvltalaf/notes/wrhvxsezas.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "wrHvxsEzas",
+ "replyTo": "msIVf6YtyP",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the AC for the thorough and balanced summary. Below we address every point MR1–MR11 concisely; each item is discussed in greater detail in the reviewer response identified in parentheses, and the corresponding revisions have been incorporated into the manuscript.\n\n**Score context.** One reviewer (ttAK) recommends acceptance with a score of 5 and rates the paper as “good” across Quality, Clarity, Significance, and Originality. We respectfully believe that the two rejection scores are primarily driven by concerns that have now been clarified or directly addressed, rather than by fundamental issues with the method or evaluation. Specifically, these concerns involve: (i) a confusion regarding the data pipeline, as our approach does not interpolate in k-space (MR1); (ii) requests for comparisons with more recent baselines, which we have now added and for which KIR-NO remains the strongest method within each resolution grid (MR3, MR4); and (iii) analyses already included in the appendix, including the component ablations in Appendix F and the matched-budget diffusion comparison in Appendix E (MR4, MR11). Importantly, the reviews recognize the paper’s central contribution, a resolution-agnostic 3D neural operator that can be trained at low resolution and deployed at high resolution, while also broadly supporting the methodological soundness of the proposed approach and its evaluation protocol.\n\n**MR1. The cross-resolution protocol preserves k-space, and the SR target is a real acquisition** *(→ KU44 W1/Q3; ttAK W1/Q1)*. We don’t interpolate in k-space. Each resolution is obtained by resizing in image space and then applying the FFT, so k-space is always the exact transform of a clean image on that grid. On SKM-TEA, the in-plane 512×512 grid is natively acquired, so KIR-NO trained on half resolution and testing on full resolution requires recovering genuinely measured high-frequency content. The confusion originates from an unfortunate typo line 300 in our manuscript, and we reiterate that **there is no interpolation of k-space.** We corrected the manuscript accordingly.\n\n**MR2. Robustness under realistic acquisition shifts** *(→ ttAK W2)*. New experiments evaluate: (a) **measurement noise** injected at sampled k-space positions, where KIR-NO leads the CNN by +1.9 to +2.9 dB PSNR at every noise level, including 8 dB, when noise-aware training is applied equally to both methods; and (b) **cross-scanner transfer** from SKM-TEA to fastMRI knee, where KIR-NO leads by +3.9 dB on few-shot and +3.15 dB on zero-shot.\n\n**MR3. Recent operator and transformer baselines added** *(→ KU44 W2; 92fo W1)*. Against **LMO (CVPR’25)**, KIR-NO performs best within every grid, with gains of +3.4, +7.1, and +7.2 dB at quarter, half, and full resolution. Against **ReconFormer (TMI’24)** under a fully zero-shot, quarter-trained protocol, KIR-NO also leads at every grid by +1.7, +1.3, and +0.6 dB.\n\n**MR4. The diffusion comparison uses matched budgets and is not limited to an unfair appendix comparison** *(→ 92fo W1)*. Appendix E reports both single-step and 11 matched-step comparisons. KIR-NO leads in both settings, including gains of +2.5 dB over Diffusion-3D-Physics and +8.0 dB over Diffusion-CSGM in the single-step, half-resolution setting. \n\n**MR5. Novelty relative to prior neural-operator MRI methods** *(→ KU44 W4/Q1; 92fo W2)*. The cited operator- and Mamba-based CS-MRI methods are 2D or slice-wise. KIR-NO is natively 3D, combining a new function-space 3D kernel, a k-space operator head, and memory-feasible volumetric training with through-plane context. None of these elements is present in the 2D formulation.\n\n**MR6. A single model generalizes zero-shot across acceleration rates** *(→ KU44 W3/Q2)*. We clarified that the 4×, 8×, and 16× results use a single set of weights. Only the sampling mask changes at test time. \n\n**MR7. Real versus simulated k-space and high-resolution data construction** *(→ ttAK Q2; MR1)*. We clarified that SKM-TEA uses real raw multi-coil k-space, while BraTS uses simulated k-space. Multi-resolution volumes are constructed by resizing in image space and then applying the FFT."
+ },
+ "createdAt": "2026-07-30T03:45:05.410Z",
+ "modifiedAt": "2026-11-19T16:59:57.009Z",
+ "url": "https://openreview.net/forum?id=WcGVLtalaf&noteId=wrHvxsEzas",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wcgvltalaf/notes/ypavthfgo6.json added

+++ b/reviews/openreview/wcgvltalaf/notes/ypavthfgo6.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "yPAvtHFGo6",
+ "replyTo": "YryRzQawgk",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer KU44,\n\nThank you for taking the time to review our rebuttal and reconsider your assessment. We appreciate that our clarifications addressed some of your concerns.\n\nCould you please indicate which concerns remain insufficiently addressed, particularly those that are most important to your evaluation? We would be grateful for the opportunity to provide further clarification, additional analysis, or more concrete details about the revisions we plan to make within the discussion period."
+ },
+ "createdAt": "2026-08-02T04:08:01.432Z",
+ "modifiedAt": "2026-11-19T16:59:57.134Z",
+ "url": "https://openreview.net/forum?id=WcGVLtalaf&noteId=yPAvtHFGo6",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/wcgvltalaf/notes/zr79jn6b18.json added

+++ b/reviews/openreview/wcgvltalaf/notes/zr79jn6b18.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "zR79jn6b18",
+ "replyTo": "B0Leipt1ud",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "**W3 — Ablations, and why training at half and evaluate at quarter**\n\nWe thank the reviewer and take this opportunity to clarify two points:\n\n**(a) Kernel-basis ablation** is presented in Appendix F (piecewise-linear basis ≫ Morlet). We moved it to the main text.\n\n**(b) Half → quarter row** is included only for **completeness of reporting**, as a downward-generalisation check and show the proposed KIR-NO works across resolutions, instead of claiming train on high resolution and test on low resolution is a practical clinical use. The super-resolution setting we actually target is **train-low → evaluate-high** (half → full), and we now label the two directions clearly so the purpose of each row is clear.\n\n**W4 — VRAM cost and the quarter-trained setting**\n\nWe appreciate this point and would like to make three observations.\n\n**(1)** High VRAM is precisely the bottleneck in 3D MRI reconstruction that this work exists to alleviate.\n\n**(2)** **Training memory scales with the training resolution, not the deployment resolution.** Because KIR-NO learns in function space, it can reconstruct at $(256 \\times 256 \\times 160)$ after training at only $(128 \\times 128 \\times 80)$. This uses **57% less memory** than half-resolution training (19.8 vs. 45.8 GB) and has a lower per-step cost than half-resolution CNN training.\n\n**(3)** The quarter-trained model retains its accuracy at the target resolution:\n\n| Trained at → | Quarter 128×128×80 | Half 256×256×160 |\n| --- | --- | --- |\n| 3D E2E-VarNet (CNN) | 31.11 | 31.44 |\n| **KIR-NO (ours)** | **34.06** | **34.74** |\n\nThis shows that reducing the training resolution by half decreases performance by only 0.68 dB for KIR-NO. Moreover, at the same target resolution, **the quarter-trained KIR-NO outperforms the half-trained CNN by 2.6 dB**. \n\nAlthough the CNN can also be evaluated off-grid, its accuracy is consistently lower at every resolution, achieving 31.11 dB at half resolution compared with 34.06 dB for KIR-NO. Finally, within our available memory budget, the CNN could not be trained on the $(512 \\times 512 \\times 320)$ grid, whereas KIR-NO reaches this resolution zero-shot.\n\n**Formatting — forward reference to Fig. 1**\n\nThank you for catching this formatting issue. We added a local reference and relocated the content so that the figure is introduced where it is first discussed.",
+ "title": "Response to Reviewer 92fo (2/2)"
+ },
+ "createdAt": "2026-07-30T03:35:53.498Z",
+ "modifiedAt": "2026-11-19T16:59:57.276Z",
+ "url": "https://openreview.net/forum?id=WcGVLtalaf&noteId=zR79jn6b18",
+ "license": "CC-BY-4.0"
+}