MID: Mask-Image Distributional Divergence for Evaluating Medical Image Segmentation
Update NeurIPS 2026 submission Oxe8M9Grah: 4 notes
@openreview[bot] · 2026-11-24 15:50 UTC · 81c254f46cc0 ·
reviews/openreview/oxe8m9grah/notes/2tyut4kqz2.json added
+++ b/reviews/openreview/oxe8m9grah/notes/2tyut4kqz2.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "2TYUT4KQZ2",+ "replyTo": "5Oz8pS7lHC",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Summary for meta-reviewer",+ "comment": "Thank you for your constructive meta-review and for the structured opportunity to provide this rebuttal. We have followed the priority list you outlined, and we would like to offer a summary below to organize our responses:\n\n**Priority 1:** We have demonstrated the statistically significant advantage of the joint image-mask encoding over the mask-only baseline through a paired-cell bootstrap analysis. Details about the experimental setup and results obtained are provided in the answer to **question 2 from reviewer 3hRR**.\n\n**Priority 2:** We have addressed the single-Gaussian assumption on bimodal references through new experiments. Details are provided in the answer to **question 4 from reviewer 3hRR and question 1 from reviewer 4VEL**.\n\n**Priority 3:** We have investigated the small-sample bias and provided guidance on sample-size requirements for practical deployment. Please refer to **question 3 from reviewer 3hRR and question 2 from reviewer 4VEL for details.** \n\n**Priority 4:** We have corrected the symmetry claim regarding our estimator, which arose from a typographic error in the submitted manuscript. We clarify its reference-conditioned nature in response to the **limitation raised by reviewer 3hRR**.\n\nAdditionally, we have provided detailed responses to all concerns raised by each reviewer. We remain available for any further questions and look forward to the remaining reviewers' feedback."+ },+ "createdAt": "2026-08-03T10:15:22.711Z",+ "modifiedAt": "2026-11-19T17:04:53.016Z",+ "url": "https://openreview.net/forum?id=Oxe8M9Grah¬eId=2TYUT4KQZ2",+ "license": "CC-BY-4.0"+}
reviews/openreview/oxe8m9grah/notes/5oz8ps7lhc.json modified
+++ b/reviews/openreview/oxe8m9grah/notes/5oz8ps7lhc.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair NhHX","content": {- "metareview": "This paper proposes MID, a distribution-level metric that scores medical image segmentation without per-sample ground truth. It received two accepts and one borderline accept.\n\nI have read the authors' response, and it addressed the four priorities from my initial meta-review. On the main point, a paired-cell bootstrap on a within-organ CT subset now shows a clear and significant advantage of the joint image-mask encoding over the mask-only baseline, once organ-scale effects that had hidden it in the original table are removed. The single-Gaussian concern was answered with a Gaussian-mixture comparison whose rankings match the default estimator, so the bimodal reference does not change the model ordering. The small-sample bias was addressed with a matched-size reanalysis and explicit sample-size guidance, and the symmetry claim was corrected. The reviewer who was initially unsure raised the score and agreed the follow-ups were credible.\n\nI recommend acceptance. The metric is well motivated, the validation across 13 datasets is thorough, the code is released, and the remaining reservations were answered from data the authors already had.\n\nOne item the authors must fix. The program chairs' citation checker flagged two references whose author lists are wrong: both cite real papers (Rad-DINO, and the topologically-faithful segmentation paper) but add people who are not authors and change or drop names. The authors must check every reference against the primary source and correct the author lists for the camera-ready. The authors should also fold the new within-organ significance analysis, the mixture-reference comparison, and the sample-size guidance into the paper."+ "metareview": "This paper proposes MID, a distribution-level metric that scores medical image segmentation without per-sample ground truth. It received two accepts and one borderline accept.\n\nI have read the authors' response, and it addressed the four priorities from my initial meta-review. On the main point, a paired-cell bootstrap on a within-organ CT subset now shows a clear and significant advantage of the joint image-mask encoding over the mask-only baseline, once organ-scale effects that had hidden it in the original table are removed. The single-Gaussian concern was answered with a Gaussian-mixture comparison whose rankings match the default estimator, so the bimodal reference does not change the model ordering. The small-sample bias was addressed with a matched-size reanalysis and explicit sample-size guidance, and the symmetry claim was corrected. The reviewer who was initially unsure raised the score and agreed the follow-ups were credible.\n\nI recommend acceptance. The metric is well motivated, the validation across 13 datasets is thorough, the code is released, and the remaining reservations were answered from data the authors already had.\n\nOne item the authors must fix. The program chairs' citation checker flagged two references whose author lists are wrong: both cite real papers (Rad-DINO, and the topologically-faithful segmentation paper) but add people who are not authors and change or drop names. The authors must check every reference against the primary source and correct the author lists for the camera-ready. The authors should also fold the new within-organ significance analysis, the mixture-reference comparison, and the sample-size guidance into the paper.",+ "final_justification": "Accept. The rebuttal addressed all four priorities: within-organ statistical separation from the mask-only baseline (on a re-scoped subset), ranking consistency under a Gaussian-mixture reference, small-sample control with usage guidance, and the symmetry correction. The initially unsure reviewer moved to borderline accept. Two references have incorrect author lists that the authors must correct for the camera-ready."},"createdAt": "2026-07-23T15:20:21.688Z",- "modifiedAt": "2026-11-18T15:18:38.053Z",+ "modifiedAt": "2026-11-19T04:59:13.363Z","url": "https://openreview.net/forum?id=Oxe8M9Grah¬eId=5Oz8pS7lHC","license": "CC-BY-4.0"}
reviews/openreview/oxe8m9grah/notes/c7bkczbamo.json added
+++ b/reviews/openreview/oxe8m9grah/notes/c7bkczbamo.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "c7BKczBaMo",+ "replyTo": "o9fRxdDLGH",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer CbnY",+ "content": {+ "title": "Thank you for the rebutal",+ "comment": "Thank you for the detailed rebuttal. I appreciate that the paper addresses an interesting question in an elegant way and will retain my positive score."+ },+ "createdAt": "2026-07-31T08:48:57.676Z",+ "modifiedAt": "2026-11-19T17:04:53.097Z",+ "url": "https://openreview.net/forum?id=Oxe8M9Grah¬eId=c7BKczBaMo",+ "license": "CC-BY-4.0"+}
reviews/openreview/oxe8m9grah/notes/jejtgxrcuz.json added
+++ b/reviews/openreview/oxe8m9grah/notes/jejtgxrcuz.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "jejTgxRCuZ",+ "replyTo": "c7BKczBaMo",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Many thanks for letting us know that your questions have been addressed and for confirming your positive score."+ },+ "createdAt": "2026-08-04T08:52:12.475Z",+ "modifiedAt": "2026-11-19T17:04:53.011Z",+ "url": "https://openreview.net/forum?id=Oxe8M9Grah¬eId=jejTgxRCuZ",+ "license": "CC-BY-4.0"+}