GradTrack: Detecting Noisy Labels via Temporal Trajectories of Class-wise Gradient Misalignment
Update NeurIPS 2026 submission x43qiqLUSG: 7 notes
@openreview[bot] · 2026-11-24 15:57 UTC · 340d1b5f4547 ·
reviews/openreview/x43qiqlusg/notes/blpelfnez7.json added
+++ b/reviews/openreview/x43qiqlusg/notes/blpelfnez7.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "BLPelfNEz7",+ "replyTo": null,+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Area Chair ntYA",+ "content": {+ "title": "Rebuttal discussion",+ "comment": "Dear reviewers,\n\nAs we move toward the end of the discussion period for the authors, I kindly ask each of you to review the authors’ rebuttal and provide an updated assessment. Some of the raised concerns may now be resolved, while others might still require clarification.\n\nTo support a clear and constructive meta‑review, please indicate:\n - Which concerns you consider fully addressed.\n\n - Which remain unresolved or insufficiently answered.\n\n - Any new issues, if any, introduced by the rebuttal. \n\nYour timely feedback will help ensure consistency and fairness in the evaluation.\n\nThanks,\nyour AC."+ },+ "createdAt": "2026-07-31T17:23:22.701Z",+ "modifiedAt": "2026-11-19T16:42:55.539Z",+ "url": "https://openreview.net/forum?id=x43qiqLUSG¬eId=BLPelfNEz7",+ "license": "CC-BY-4.0"+}
reviews/openreview/x43qiqlusg/notes/dabkldmvso.json added
+++ b/reviews/openreview/x43qiqlusg/notes/dabkldmvso.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "dabklDMVsO",+ "replyTo": "um34lM3LDY",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for the follow-up, and apologies for the delayed response. We conducted additional experiments and found that the primary source of the performance gap is the training duration. In our previous experiments, we adopted the same 30-epoch training schedule used for CLIP on CIFAR-10 settings. However, our further investigation showed that the ResNet-50 model had not yet converged after 30 epochs, leading to the observed performance gap. We therefore retrained the CIFAR-10 model for 50 epochs to be consistent with the other experimental settings. The updated results are presented in Table R2.2. For completeness, we also include the CIFAR-100 and Tiny-ImageNet results, which remain unchanged from Table R2.1 in our last reply.\n\nFor CIFAR-10 Asym. 0.3, the GradTrack performance (63.99) is now comparable with SimiFeat-V (65.94).\n\nFor CIFAR-10N Agg. 0.09, although the performance improved, the gap between SIMIFeat-V and GradTrack remains large. Our analysis indicates that this arises from the same over-cleansing failure mode discussed in R3-Q1. Specifically, GradTrack achieves an AUC of 96.38% and a recall of 96.98%, but its precision drops to only 27.66%, corresponding to an effective predicted noise rate of 31.59% (compared with 15.14% for the CLIP-based model), substantially higher than the true noise rate of 9.01%.\n\n`Table R2.2`\n\n| Setting | SimiFeat-V | GradTrack (CIFAR-10 30 epochs, rest 50 epochs) | GradTrack (All 50 epochs) |\n| --- | --- | --- | --- |\n| CIFAR-10 Sym. 0.6 | 93.28 | 96.27 | 96.53 |\n| CIFAR-10 Asym. 0.3 | 65.94 | 42.29 | 63.99 |\n| CIFAR-10 Inst. 0.4 | 82.37 | 94.22 | 94.50 |\n| CIFAR-10N Worst 0.4 | 87.14 | 88.43 | 88.64 |\n| CIFAR-10N Agg. 0.09 | 66.94 | 39.99 | 43.05 |\n| CIFAR-100 Sym. 0.6 | 86.11 | 94.52 | 94.52 |\n| CIFAR-100 Asym. 0.3 | 68.19 | 78.36 | 78.36 |\n| CIFAR-100 Inst. 0.4 | 76.70 | 91.67 | 91.67 |\n| CIFAR-100N Human 0.4 | 75.25 | 73.60 | 73.60 |\n| Tiny-ImageNet Sym. 0.6 | 76.60 | 94.33 | 94.33 |\n| Tiny-ImageNet Inst. 0.4 | 76.72 | 86.96 | 86.96 |\n| Average F1 (%) | 77.75 | 80.06 | 82.38 |\n\nWe believe the performance difference between the CLIP- and ResNet-50-based models arises from differences in their pretraining. CLIP was pretrained on a substantially larger and diverse corpus, whereas ResNet-50 was pretrained only on ImageNet. ResNet-50 requires a longer training period to converge on CIFAR-10. One possible explanation is that CLIP's large-scale pretraining produces latent representations that are more transferable to the downstream task, allowing the model to converge more rapidly during fine-tuning. At the CIFAR-10N Agg. 0.09 low-noise setting, the slower convergence amplifies the threshold-sensitivity issue, resulting in the over-cleansing behaviour observed above. We will discuss those aspects of the model differences in the revised paper."+ },+ "createdAt": "2026-08-04T11:38:50.866Z",+ "modifiedAt": "2026-11-19T16:42:54.981Z",+ "url": "https://openreview.net/forum?id=x43qiqLUSG¬eId=dabklDMVsO",+ "license": "CC-BY-4.0"+}
reviews/openreview/x43qiqlusg/notes/powzm4brzr.json modified
+++ b/reviews/openreview/x43qiqlusg/notes/powzm4brzr.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair ntYA","content": {- "metareview": "The paper introduces GradTrack, a gradient‑dynamics–based framework for noisy‑label detection. The method estimates class‑wise clean‑label gradient directions from low‑ and medium‑magnitude samples, computes per‑sample gradient misalignment scores, and aggregates these signals across training epochs using temporal rank trajectories and a GMM. The idea is intuitive and the empirical results are strong on several synthetic and real‑world benchmarks, particularly under instance‑dependent noise. The method is simple to integrate into existing LNL pipelines and shows consistent improvements in high‑noise regimes.\n\nHowever, the reviewers have identified several substantial concerns that limit the contribution. The conceptual foundation relies heavily on three empirical observations demonstrated only on a single dataset, encoder, and noise type, without statistical validation or evidence that the gradient‑alignment patterns generalize across architectures, datasets, or training dynamics. These observations are treated as universal properties of noisy‑label learning, but the paper provides no justification for this assumption. Furthermore, it seems that the core design choice contradicts the paper's own Observation 2. In particular, the analysis from Fig 2 concludes that low-magnitude gradients are the least informative for estimating the true clean direction, and that the medium-magnitude group is the best approximator. Nevertheless, the proposed method anchors $\\mu_c$ using bottom-K (i.e., lowest magnitude) in Eq 2 (note that the entire misalignment score and downstream detection depend on $\\mu_c$). In addition, the pipeline itself is complex and involves multiple interacting components (gradient partitioning, class‑wise bottom‑K selection, SVD denoising, temporal rank modeling, GMM), which incurs higher complexity times, yet the paper provides no analysis about this. How these components interact, whether they are stable across training conditions, or under what regimes they may fail remains also unexplored. This makes it difficult to assess the robustness of the overall approach.\n\nIn terms of empirical vallidation, the evaluation is restricted to a frozen CLIP encoder, whose gradient dynamics may differ significantly from standard CNNs or ViTs (not trained in a contrastive manner), making unclear whether the proposed approach remains effective in more conventional settings or other architectures (even in the current validation only one backbone is used along all experiments). Moreover, an important concern raised is that the method performs poorly in realistic low‑noise regimes (e.g., CIFAR‑10N Agg), suggesting over‑cleansing and lack of calibration, but the paper does not analyze this failure mode. Finally, and related to the higher complexity times concern, the scalability of the approach (which requires per‑sample gradient tracking across epochs and repeated SVD computations) is not discussed, which might not be scalable or practical for real‑world settings."+ "metareview": "The paper introduces GradTrack, a gradient‑dynamics–based framework for noisy‑label detection. The method estimates class‑wise clean‑label gradient directions from low‑ and medium‑magnitude samples, computes per‑sample gradient misalignment scores, and aggregates these signals across training epochs using temporal rank trajectories and a GMM. The idea is intuitive and the empirical results are strong on several synthetic and real‑world benchmarks, particularly under instance‑dependent noise. The method is simple to integrate into existing LNL pipelines and shows consistent improvements in high‑noise regimes.\n\nHowever, the reviewers have identified several substantial concerns that limit the contribution. The conceptual foundation relies heavily on three empirical observations demonstrated only on a single dataset, encoder, and noise type, without statistical validation or evidence that the gradient‑alignment patterns generalize across architectures, datasets, or training dynamics. These observations are treated as universal properties of noisy‑label learning, but the paper provides no justification for this assumption. Furthermore, it seems that the core design choice contradicts the paper's own Observation 2. In particular, the analysis from Fig 2 concludes that low-magnitude gradients are the least informative for estimating the true clean direction, and that the medium-magnitude group is the best approximator. Nevertheless, the proposed method anchors $\\mu_c$ using bottom-K (i.e., lowest magnitude) in Eq 2 (note that the entire misalignment score and downstream detection depend on $\\mu_c$). In addition, the pipeline itself is complex and involves multiple interacting components (gradient partitioning, class‑wise bottom‑K selection, SVD denoising, temporal rank modeling, GMM), which incurs higher complexity times, yet the paper provides no analysis about this. How these components interact, whether they are stable across training conditions, or under what regimes they may fail remains also unexplored. This makes it difficult to assess the robustness of the overall approach.\n\nIn terms of empirical vallidation, the evaluation is restricted to a frozen CLIP encoder, whose gradient dynamics may differ significantly from standard CNNs or ViTs (not trained in a contrastive manner), making unclear whether the proposed approach remains effective in more conventional settings or other architectures (even in the current validation only one backbone is used along all experiments). Moreover, an important concern raised is that the method performs poorly in realistic low‑noise regimes (e.g., CIFAR‑10N Agg), suggesting over‑cleansing and lack of calibration, but the paper does not analyze this failure mode. Finally, and related to the higher complexity times concern, the scalability of the approach (which requires per‑sample gradient tracking across epochs and repeated SVD computations) is not discussed, which might not be scalable or practical for real‑world settings.",+ "final_justification": "This submission received an overall positive feedback from the reviewers, with three borderline accepts. In addition to reviewers comments, this AC went through the initial reviews and raised additional concerns, which were mostly addressed by the authors during the rebuttal/discussion process. Given the new evidence, clarifications and responses from authors, I recommend the acceptance of this work, and strongly encourage the authors to include their responses into the final manuscript, which will further improve this work."},"createdAt": "2026-07-22T01:20:02.943Z",- "modifiedAt": "2026-11-18T15:18:48.076Z",+ "modifiedAt": "2026-11-19T04:59:18.774Z","url": "https://openreview.net/forum?id=x43qiqLUSG¬eId=powzM4BrZr","license": "CC-BY-4.0"}
reviews/openreview/x43qiqlusg/notes/qgp8lef5rw.json added
+++ b/reviews/openreview/x43qiqlusg/notes/qgp8lef5rw.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "qgP8LEF5Rw",+ "replyTo": "vVxXxJZZTx",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you very much for your time and positive evaluation of our work. We truly appreciate your thoughtful review and constructive feedback, which have helped us significantly improve the quality and presentation of our paper. We hope that our rebuttal has successfully resolved your concerns."+ },+ "createdAt": "2026-08-04T11:44:00.682Z",+ "modifiedAt": "2026-11-19T16:42:54.827Z",+ "url": "https://openreview.net/forum?id=x43qiqLUSG¬eId=qgP8LEF5Rw",+ "license": "CC-BY-4.0"+}
reviews/openreview/x43qiqlusg/notes/rrltfzkoem.json added
+++ b/reviews/openreview/x43qiqlusg/notes/rrltfzkoem.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "rrLTFZkOeM",+ "replyTo": "C8VOuUC5dU",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you very much for your time and positive evaluation of our work. We truly appreciate your thoughtful review and constructive feedback, which have helped us significantly improve the quality and presentation of our paper. We hope that our rebuttal has successfully resolved your concerns."+ },+ "createdAt": "2026-08-04T11:44:13.343Z",+ "modifiedAt": "2026-11-19T16:42:54.799Z",+ "url": "https://openreview.net/forum?id=x43qiqLUSG¬eId=rrLTFZkOeM",+ "license": "CC-BY-4.0"+}
reviews/openreview/x43qiqlusg/notes/um34lm3ldy.json added
+++ b/reviews/openreview/x43qiqlusg/notes/um34lm3ldy.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "um34lM3LDY",+ "replyTo": "YSypCoqbl0",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer hgdm",+ "content": {+ "comment": "Thank you for your response. It has addressed most of my questions.\nI did notice that with ResNet-50, some results (e.g., CIFAR-10N Agg. 0.09 and CIFAR-10 Asym. 0.3) show a large gap from SimiFeat-V. If possible, I would like to know whether you have any further analysis on why this occurs."+ },+ "createdAt": "2026-08-03T15:37:03.340Z",+ "modifiedAt": "2026-11-19T16:42:54.982Z",+ "url": "https://openreview.net/forum?id=x43qiqLUSG¬eId=um34lM3LDY",+ "license": "CC-BY-4.0"+}
reviews/openreview/x43qiqlusg/notes/vuqcnpexlx.json added
+++ b/reviews/openreview/x43qiqlusg/notes/vuqcnpexlx.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "vuqCNPexlx",+ "replyTo": "powzM4BrZr",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We sincerely thank the Area Chair (AC) for the thoughtful, constructive, and detailed feedback. Several of the AC concerns have been addressed in our responses to Reviewers 1GU4 (R1), hgdm (R2), and RE1F (R3) below:\n\n1. **AC-Q1. Statistical support for Observations 1--3.** Please see R1-Q1 and Table R1.1. We validate the observations across all 11 settings, discuss the exceptions, and will revise the observation wording to match the empirical evidence.\n2. **AC-Q4. Frozen-CLIP-only evaluation.** Please see R2-Q3 and Table R2.1. With a non-CLIP encoder, frozen ImageNet-pretrained ResNet-50, GradTrack still improves average F1 over SimiFeat-V: **80.06% vs. 77.75%**, showing the gain is not CLIP-specific.\n3. **AC-Q5. CIFAR-10N Agg. over-cleansing.** Please see R3-Q1 and Table R3.1. CIFAR-10N Agg. fails mainly due to over-cleansing at very low noise rate, not because the ranking signal collapses. We will add this precision/recall analysis and discuss threshold calibration in the revision. GradTrack remains strong on the other real-world settings: CIFAR-10N Worst **91.63** and CIFAR-100N Human **79.12**.\n\nWe address the remaining AC-raised points below and welcome further discussions.\n\n**AC-Q2. Clarification regarding the “contradiction” between Fig. 2, Observation 2, and Eq. 2.**\n\nWe clarify that Observation 2 does not imply using the medium-magnitude group alone. Fig. 2(b) shows that the high-magnitude group is least aligned with the clean-label gradient, while the low- and medium-magnitude groups both contain useful clean-gradient signal. The word “best” referred to the medium group having the highest cosine similarity in Fig. 2(b), but the method uses this to motivate including medium-magnitude samples in addition to low-magnitude samples. Specifically, Eq. 2 selects the class-wise bottom-$K$ anchor from $S^e_{l+m}$, which contains both low- and medium-magnitude groups (L170), rather than from the global low group alone. We will revise Observation 2 as described in R1-Q1.\n\n**AC-Q3. Pipeline component interaction and stability.**\n\nSec. 5.4, Fig. 4, and Appendix Table 3 ablate the pipeline progressively: magnitude only, class-wise misalignment without SVD, SVD with all gradients, SVD with $S^e_{l+m}$, and the full trajectory. Table AC.1 maps the AC-requested components to the relevant existing or new analyses, including gradient partitioning, bottom-$K$ sensitivity, SVD denoising, temporal rank modeling, and the GMM ablation in R1-Q2.\n\n`Table AC.1`\n\n| **AC named components** | Ablation studies | Conclusion |\n| --- | --- | --- |\n| gradient partitioning (existing analysis) | Sec. A.4 and Fig.8-(a) | Performance is stable across the tested 20-60-20, 25-50-25, and 33-33-33 low/medium/high gradient magnitude partitions. |\n| class‑wise bottom‑K selection (new experiment) | New ablation testing $K \\in \\{10,25,50,100,200,500\\}$ (please see Table AC.2) | F1 stays consistent across the tested $K$ , with the peak performance appearing at $K=50- 100$. |\n| SVD denoising (existing analysis) | Sec. A.2 and Fig. 6 | Results are stable across the tested range of $\\lambda$, only dropping when the full spectrum is retained. |\n| temporal rank modeling (existing analysis) | We have shown ablation studies on two aspects: (a) Rank trajectory ranking: Sec. A.3 and Fig. 7. (b) How the temporal signals are aggregated: Sec. A.5 and Fig. 8-(b) | Results are consistent across the tested $\\rho$ values and temporal aggregation strategies. |\n| GMM (new experiment) | New experiment as requested by R1-Q2 (please see Table R1.2) | The proposed 2-component GMM performs better than K-means and more sophisticated HDBSCAN [ref 1-2]. |\n\n`Table AC.2`\n\n| $K$ | 10 | 25 | 50 | 100 | 200 | 500 |\n| --- | --- | --- | --- | --- | --- | --- |\n| Average F1 (%) | 85.73 (±9.53) | 85.23 (±10.4) | 87.15 (±8.6) | **87.40 (±8.16)** | 85.28 (±13.85) | 84.66 (±12.78) |\n\n**AC-Q6. Scalability.** \n\nWe profiled GradTrack's compute cost on Tiny-ImageNet (instance-dependent noise, $\\eta=0.4$; 200 classes, 100k training images, 50 epochs) - the most computationally heavy setting:\n\n| Stage | Per epoch (s) | Total (s) | % of wall time |\n| --- | --- | --- | --- |\n| Gradient extraction | 215.3 | 10,765.0 | 98.97 |\n| Misalignment projection | 1.20 | 60.0 | 0.55 |\n| SVD denoising (subspace construction) | 0.77 | 38.5 | 0.35 |\n| Class-wise bottom-K anchor selection | 0.15 | 7.5 | 0.069 |\n| Gradient partitioning | 0.066 | 3.3 | 0.030 |\n| GMM isolation | one-off computation | 1.9 | 0.017 |\n| Temporal rank modeling | one-off computation | 1.3 | 0.012 |\n| **Total (GradTrack added computation)** | — | 112.5 s (1m 52.5s) | **1.03** |\n\nPer-sample gradient extraction dominates runtime (**98.97%**). All GradTrack-specific steps together add only **112.5s**, or **1.03%** of total wall-clock time. Thus, the main cost comes from per-sample gradient extraction, which is common to gradient-based detection methods such as TracIn [34]. We will add this profiling table to the paper."+ },+ "createdAt": "2026-07-29T03:50:15.724Z",+ "modifiedAt": "2026-11-19T16:42:55.002Z",+ "url": "https://openreview.net/forum?id=x43qiqLUSG¬eId=vuqCNPexlx",+ "license": "CC-BY-4.0"+}