potentialpaper

Anatomy-Activated Mixture-of-Experts for 3D Medical Vision-Language Pre-training

Import NeurIPS 2026 submission cOJs7gDYiz: 8 notes

@openreview[bot] · 2026-11-22 17:58 UTC · 1c5a8737d057

Evidence

.gitattributes added

+++ b/.gitattributes
@@ -0,0 +1,10 @@
+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),
+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.
+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text
+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text
+/thumbnail.png filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text
+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text
+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text

.potentialpaper/metadata.json added

+++ b/.potentialpaper/metadata.json
@@ -0,0 +1,32 @@
+{
+ "layout": 5,
+ "identifiers": [
+ {
+ "scheme": "openreview",
+ "value": "cOJs7gDYiz"
+ }
+ ],
+ "title": "Anatomy-Activated Mixture-of-Experts for 3D Medical Vision-Language Pre-training",
+ "authors": [
+ "Szymon Plotka",
+ "Gizem Mert",
+ "Pedro R. A. S. Bassi",
+ "Wenxuan Li",
+ "Zongwei Zhou",
+ "Anna M Marcinkiewicz",
+ "Wiktoria Romańczyk",
+ "Jarosław B. Ćwikła",
+ "Łukasz Struski",
+ "Ewa Szczurek",
+ "Jacek Tabor",
+ "Arkadiusz Sitek"
+ ],
+ "abstract": "Medical Vision-Language Pre-training (VLP) leverages the semantic richness of radiology reports to learn 3D representations, yet current architectures remain fundamentally anatomy-agnostic. While clinical diagnostics rely on organ-specific context, standard encoders apply a uniform, dense parameterization to all volumetric patches, and existing Mixture-of-Experts (MoE) routers gate on isolated local features without explicit access to the organ composition of the scan or crop.\nWe propose Anatomy-Activated Mixture-of-Experts (A$^{2}$MoE), a framework that incorporates anatomical inductive biases within the model's computational path. A$^{2}$MoE introduces two key components: (1) a Histogram Representation Router (HRR) that conditions expert selection on global visual context and a predicted anatomical\ncomposition histogram, encouraging anatomy-dependent expert weighting; and (2) an Organ-Query Multi-Scale Projector (OQMSP) that utilizes learnable queries to extract organ-level embeddings for fine-grained alignment without requiring manual annotations at inference. By routing at the patch level rather than the token level, A$^{2}$MoE reduces routing complexity by orders of magnitude while satisfying load balancing by construction. Pre-trained on over 60,000 multi-phase CT scans, A$^{2}$MoE achieves state-of-the-art performance across segmentation, classification, and detection benchmarks. Furthermore, we demonstrate that our anatomically grounded inductive biases support robust generalization to MRI and ultrasound, establishing a scalable foundation for medical representation learning.",
+ "year": 2026,
+ "venue": "NeurIPS 2026",
+ "source": "openreview",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}

community/10-tl-dr.md added

+++ b/community/10-tl-dr.md

community/20-summary.md added

+++ b/community/20-summary.md

community/30-why-it-matters.md added

+++ b/community/30-why-it-matters.md

community/40-critique.md added

+++ b/community/40-critique.md

community/50-errata.md added

+++ b/community/50-errata.md

community/60-reproductions.md added

+++ b/community/60-reproductions.md

community/70-follow-ups.md added

+++ b/community/70-follow-ups.md

owners/10-tl-dr.md added

+++ b/owners/10-tl-dr.md

owners/20-overview.md added

+++ b/owners/20-overview.md

owners/30-results.md added

+++ b/owners/30-results.md

owners/40-demos.md added

+++ b/owners/40-demos.md

owners/50-code-and-data.md added

+++ b/owners/50-code-and-data.md

owners/60-talks.md added

+++ b/owners/60-talks.md

prek.toml added

+++ b/prek.toml
@@ -0,0 +1,36 @@
+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.
+# The site checks every push again; these catch mistakes before you commit. The same on every page.
+
+[[repos]]
+repo = "builtin"
+hooks = [
+ { id = "check-json" },
+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },
+ { id = "end-of-file-fixer", exclude = '^demos/' },
+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },
+ { id = "check-case-conflict" },
+ { id = "check-illegal-windows-names" },
+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },
+]
+
+# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).
+[[repos]]
+repo = "https://github.com/python-jsonschema/check-jsonschema"
+rev = "0.39.0"
+hooks = [
+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },
+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },
+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },
+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },
+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },
+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },
+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },
+]
+
+# Sections formatted the way the web editor formats them.
+[[repos]]
+repo = "https://github.com/rbubley/mirrors-prettier"
+rev = "v3.9.9"
+hooks = [
+ { id = "prettier", files = '^(owners|community)/.*\.md$' },
+]

reviews/openreview/cojs7gdyiz/forms.json added

+++ b/reviews/openreview/cojs7gdyiz/forms.json
@@ -0,0 +1,227 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ },
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "quality",
+ "clarity",
+ "significance",
+ "originality"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 6
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 5
+ },
+ {
+ "key": "quality",
+ "label": "Quality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "clarity",
+ "label": "Clarity",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "significance",
+ "label": "Significance",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "originality",
+ "label": "Originality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "contribution_type",
+ "label": "Contribution type",
+ "type": "choice"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "strengths_and_weaknesses",
+ "label": "Strengths and weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions",
+ "label": "Questions",
+ "type": "text"
+ },
+ {
+ "key": "limitations",
+ "label": "Limitations",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ },
+ {
+ "key": "paper_formatting_concerns",
+ "label": "Formatting concerns",
+ "type": "text"
+ },
+ {
+ "key": "ethical_concerns",
+ "label": "Ethical concerns",
+ "type": "choice"
+ },
+ {
+ "key": "code_of_conduct_acknowledgement",
+ "label": "Code of conduct",
+ "hidden": true
+ },
+ {
+ "key": "responsible_reviewing_acknowledgement",
+ "label": "Responsible reviewing",
+ "hidden": true
+ }
+ ]
+ },
+ "Rebuttal": {
+ "label": "Rebuttal",
+ "fields": [
+ {
+ "key": "rebuttal",
+ "label": "Rebuttal",
+ "type": "text"
+ }
+ ]
+ },
+ "Ethics_Review": {
+ "label": "Ethics review",
+ "fields": [
+ {
+ "key": "scope_of_ethics_concerns",
+ "label": "Scope",
+ "type": "choice"
+ },
+ {
+ "key": "ethics_review",
+ "label": "Ethics review",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/cojs7gdyiz/notes/5ey1lwqpx8.json added

+++ b/reviews/openreview/cojs7gdyiz/notes/5ey1lwqpx8.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "5EY1lWqPX8",
+ "replyTo": "EcRMwfFfRH",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "We thank the reviewer for a thorough and generous assessment of the motivation, breadth of evaluation, and originality of the work. We address their comments below.\n\n\n> **W1: The full model introduces substantially more parameters than the base SegMamba model [...]**\n\n\nThis is a fair concern, and we realize our parameter reporting was misleading. The reported parameter gap is largely an accounting artifact. The 203.1M count for the full model includes the frozen PubMedBERT text encoder (119.6M), which was used only for pre-training alignment and discarded during downstream inference; OQMSP itself contributes only ~4M. We recomputed the trainable parameters and obtained the following: (i) SegMamba – **65.5M**, (ii) SegMamba + A$^{2}$MoE – **79.5M**, and (iii) SegMamba + A$^{2}$MoE + OQMSP – **83.5M**. Thus, our proposed VLM model is comparable to other state-of-the-art VLMs used for comparison, such as fVLM and BTB3D, and significantly lower than Merlin. We now clarified this in the revised submission.\n\n> **W2: The ablation analysis is stronger for segmentation than for the other downstream tasks [...]**\n\nWe agree this was a gap and have extended the #1/#2/#3 ablation ladder to both remaining tasks.\n\nFor RATIC classification, we report the ROC-AUC for each of the four classes, as well as their mean:\n\n| Config | Bowel | Liver | Kidney | Spleen | ROC-AUC |\n| :--- | :---: | :---: | :---: | :---: | :---: |\n| #1 SegMamba | 73.2 | 77.1 | 90.5 | 89.0 | 83.0 |\n| #2 + A$^{2}$MoE | 78.7 | 81.6 | 92.5 | 90.9 | 86.1 |\n| #3 + OQMSP (ours) | 82.4 | 84.6 | 93.8 | 92.1 | 88.2 |\n\n\nFor AbdomenAtlas 3.0 detection, we report Sensitivity (Sen.) for $\\leq$ 2 cm and $\\gt$ 2 cm lesions, and Specificity (Spec.):\n\n| Config | | Pancreatic tumor | | | Kidney tumor | | | Liver tumor | |\n| :----------- | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: |\n| | Sen. ($\\leq$ 2cm) | Sen. (> 2cm)| Spec. | Sen. ($\\leq$ 2cm) | Sen. (> 2cm)| Spec. | Sen. ($\\leq$ 2cm) | Sen. (> 2cm)| Spec. |\n| #1 SegMamba | 44.3 | 66.7 | 88.5 | 42.1 | 78.5 | 45.0 | 28.5 | 83.0 | 76.2 |\n| #2 A$^{2}$MoE | 58.6 | 75.0 | 91.8 | 50.3 | 88.0 | 50.2 | 35.1 | 90.4 | 81.0 |\n| #3 + OQMSP (ours) | 66.7 | 83.3 | 94.1 | 58.2 | 94.1 | 55.4 | 41.2 | 95.2 | 85.4 |\n\nWe demonstrated that our proposed key modules (A$^{2}$MoE and OQMSP) consistently improved the performance across all compared downstream tasks, including segmentation, classification and detection.\n\nWe will incorporate these complete ablation results into the camera-ready version of the manuscript.\n\nWe hope this addresses all concerns. Should any further questions arise, we remain fully available throughout the discussion period. In light of this rebuttal, we kindly ask the reviewer to consider increasing their score."
+ },
+ "createdAt": "2026-07-28T09:14:28.817Z",
+ "modifiedAt": "2026-11-18T17:11:25.224Z",
+ "url": "https://openreview.net/forum?id=cOJs7gDYiz&noteId=5EY1lWqPX8",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/cojs7gdyiz/notes/9t1xmmrisj.json added

+++ b/reviews/openreview/cojs7gdyiz/notes/9t1xmmrisj.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "9T1xMmRiSj",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer Jq6Y",
+ "content": {
+ "summary": "A2MOE is proposed - a novel mixture-of-experts method for 3D medical vision-language pretraining that intrinsically leverages the anatomical priors captured in given scans. There are two distinct methodological contributions: 1) a histogram representation router and 2) a mask free organ query multi-scale projector. The first component ensures that the model routing is guided by anatomical structure information, focusing the computation in a meaningful way. The second component, enables vision-language alignment - leveraging organ specific visual embeddings while avoiding the need for segmentation masks during inference. The validation is based on public datasets, with downstream experiments focused on segmentation, classification and detection. Overall the paper is well written, the validation is extensive and detailed.",
+ "contribution_type": "use_inspired",
+ "strengths_and_weaknesses": "Strengths:\n- The article is well structured and overall well written (perhaps with one exception, captured under weaknesses) - especially the introduction and related work lay out a clear problem statement, with the proposed solution clearly motivated.\n- The proposed method is elegant and innovative. Through the two proposed components (A2MOE and OQMSP) it addresses clear challenges, optimizing the pre-training by leveraging the anatomical information, while at the same time maintaining efficiency. The inference scheme is lightweight making the model easy to use downstream.\n- The experimental validation is extensive, a large database of over 60k CT are used for training while downstream validation focused on segmentation, classification and detection - covering central tasks in the medical image analysis domain. The are extensive details on how the reports are processed (great!) as well as for the experiments, the analysis includes lots of details on preprocessing, metrics, ablation analysis, etc.\n\nWeaknesses:\n- While the article is overall well written, IMHO the methodology section 3 could use a round of revision, with the focus on increased clarity, and revising mathematical notation (e.g., there is variable C and C_s referring to very different things, Eq. 3 uses index b, I assume for the batch? index s is sometimes used as superscript, other times as subscript; eventually even variable s_{(s)} is used). I believe a revision with focus on notation consistency, simplicity and clarity will boost readability, and allow the reader to focus much more easily. \n- The proposed method is generic, meaning it could extend beyond the segmamba backbone (fact acknowledged by the authors in the future directions). It is unfortunate that this aspect is not more central to the paper. I would not have expected to see the same depth of analysis with other backbones, but this backbone \"invariance\" is super-important for the practical impact of the proposed method. It would have been great to see even a couple of experiments, maybe focused only on one downstream - just the get a flavor.\n- Focusing on the PANORAMA challenge: it would be great to maintain the metrics from the challenge, AUC + AP; instead of redefining a new DICE-based score. The PANORAMA challenge is also highly regarded in the community, validating your method in accordance to the challenge guideline will position your results against a few quite powerful approaches, helping the reader assess the true performance against the state-of-the-art.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 3,
+ "questions": "Based on the section on strengths/weaknesses, the following changes will help boost the quality of the paper:\n- Revising the methodology section 3 with the focus on increased clarity, and improved mathematical notation. believe a revision with focus on notation consistency, simplicity and clarity will boost readability, and allow the reader to focus much more easily. I added a few concrete examples in the previous section on \"weaknesses\".\n- Focus on PANORAMA and include the validation on the challenge metrics: AUC (patient-level likelihood score) and AP (PDAC detection map). This would allow you to include the results in the article and position the performance of your approach against a couple of very strong reference solutions.\n- (Bonus): the topic of different backbones - I believe this would be super, super relevant and broadening the scope of the paper and increasing the impact. Even a dedicated section on this aspect (without experiments), discussing potential challenges that are anticipated, would be great.",
+ "limitations": "Excellent section J on limitations and future work!",
+ "rating": 5,
+ "confidence": 5,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "No concerns!",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "Great rebuttal with clear answers to my main comments."
+ },
+ "createdAt": "2026-06-18T09:09:33.876Z",
+ "modifiedAt": "2026-11-18T13:35:40.235Z",
+ "url": "https://openreview.net/forum?id=cOJs7gDYiz&noteId=9T1xMmRiSj",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/cojs7gdyiz/notes/ecrmwfffrh.json added

+++ b/reviews/openreview/cojs7gdyiz/notes/ecrmwfffrh.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "EcRMwfFfRH",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer bN4a",
+ "content": {
+ "summary": "This paper proposes Anatomy-Activated Mixture-of-Experts (A²MoE), a 3D medical vision-language pre-training framework that incorporates anatomical information into the model’s internal computation. The method introduces a Histogram Representation Router to guide expert selection using global visual context and predicted anatomy-presence information, and an Organ-Query Multi-Scale Projector to extract organ-level visual embeddings for alignment with organ-specific report text. The model is pre-trained on over 60,000 CT-report pairs and evaluated on segmentation, classification, and detection tasks across CT, MRI, and ultrasound datasets.",
+ "contribution_type": "use_inspired",
+ "strengths_and_weaknesses": "The work is technically well motivated: standard dense encoders and conventional MoE routers are largely anatomy-agnostic, while the proposed Histogram Representation Router conditions expert selection on anatomical presence information, and the Organ-Query Multi-Scale Projector extracts organ-level visual embeddings for alignment with organ-specific report text. The empirical evaluation is also broad, covering segmentation, classification, and detection across CT, MRI, and ultrasound datasets, and the ablation studies provide evidence that both the anatomy-aware routing and the organ-query alignment contribute to performance. For significance, the work addresses an important limitation in 3D medical VLP by moving anatomical grounding from a post-hoc alignment objective into the model’s internal computation, which is meaningful for medical imaging because similar visual patterns can have different diagnostic implications depending on the organ context. The originality is reasonably strong, especially in combining anatomy-conditioned MoE routing with mask-free organ-query projection for 3D medical representation learning. \n\nHowever, the full model introduces substantially more parameters than the base SegMamba model, making it difficult to isolate whether improvements come from the proposed anatomy-aware mechanism or simply from increased capacity. Second, the ablation analysis is stronger for segmentation than for the other downstream tasks; it is less clear whether the same components are equally responsible for the classification and detection gains.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 3,
+ "questions": "See strengths and weaknesses.",
+ "limitations": "Yes",
+ "rating": 5,
+ "confidence": 2,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "No obvious converns.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The additional ablation studies address my concern regarding the absence of results for classification and detection downstream tasks, thus strengthening my confidence about the work."
+ },
+ "createdAt": "2026-06-24T04:20:55.734Z",
+ "modifiedAt": "2026-11-18T13:35:39.493Z",
+ "url": "https://openreview.net/forum?id=cOJs7gDYiz&noteId=EcRMwfFfRH",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/cojs7gdyiz/notes/gfwjqidqpq.json added

+++ b/reviews/openreview/cojs7gdyiz/notes/gfwjqidqpq.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "GfWjQIDQPq",
+ "replyTo": null,
+ "kind": "meta_review",
+ "invitation": "Meta_Review",
+ "signature": "Area Chair p3ep",
+ "content": {
+ "metareview": "The paper proposes A2MoE, a 3D medical vision-language pre-training framework that introduces anatomical priors directly into expert routing and organ-level image–text alignment. The reviewers view the problem as well motivated, and the two components proposed along with A2MoE, namely HRR and OQMSP, as reasonably original. These components were validated across segmentation, classification, and detection benchmarks. Moreover, the effects span CT, MRI, and ultrasound [isoH, bN4a, Jq6Y]. The main weakness is that it remains unclear how much of the improvement comes from the proposed anatomy-aware mechanisms rather than increased model capacity, large-scale pre-training, pseudo-label supervision, and report decomposition [isoH, bN4a]. The computational-efficiency claims are also insufficiently quantified, and the paper provides limited evidence that the predicted anatomy histogram and organ queries behave as intended [isoH]. The response should therefore prioritize controlled or parameter-normalized comparisons to alternative approaches, FLOPs/memory/runtime information, clarification of whether all experts are evaluated, and evidence on histogram accuracy and organ-query localization. Clarifying the PANORAMA metrics, “mask-free” terminology, report-verification procedure, notation issues, and please remove the artifact pointed by two reviewers [isoH, Jq6Y]."
+ },
+ "createdAt": "2026-07-15T14:18:59.825Z",
+ "modifiedAt": "2026-11-18T15:18:51.297Z",
+ "url": "https://openreview.net/forum?id=cOJs7gDYiz&noteId=GfWjQIDQPq",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/cojs7gdyiz/notes/jxgoz35jiu.json added

+++ b/reviews/openreview/cojs7gdyiz/notes/jxgoz35jiu.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "JxgOz35jIU",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer isoH",
+ "content": {
+ "summary": "This paper proposes A2MoE, an anatomy-aware mixture-of-experts (MoE) framework for 3D medical vision-language pretraining. The core idea is to explicitly inject anatomical priors into the model’s computational pathway, rather than treating them merely as a post-hoc alignment signal. The method consists of an HRR router, which determines expert weights using global visual context, an organ presence histogram, and class-to-expert affinity; and OQMSP, which employs learnable organ queries to extract organ-level visual representations from multi-scale features and align them with organ-level report text. The paper reports strong performance on CT/MRI/ultrasound segmentation, trauma classification, and tumor detection tasks.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "Strengths:\n1. The paper presents a clear and medically well-motivated problem formulation. Since visual patterns in medical imaging are highly dependent on organ context, incorporating anatomical priors into the routing mechanism is more aligned with clinical diagnostic logic than relying solely on image-text contrastive alignment.\n\n2. The proposed HRR and OQMSP modules are both novel and well designed. In particular, HRR leverages crop/stage-level anatomy histograms and class-to-expert affinity matrices to encourage expert specialization, which may help reduce semantic collisions across different organs. OQMSP, on the other hand, provides a valuable organ-level alignment mechanism by enabling soft organ pooling through learnable organ queries without relying on ground-truth masks during inference.\n\n3. The experimental evaluation is comprehensive and demonstrates strong generalization. The method is evaluated across multiple segmentation benchmarks, including AMOS-CT, PANORAMA, AMOS-MRI, GEPAR3D, MRISegmenter, and MVSeg, as well as on RATIC classification and AbdomenAtlas detection. The improvements are reflected not only in Dice scores but also in HD95, suggesting that anatomy-aware routing may indeed improve robustness to boundary errors and distant mis-segmentation.\n\nWeakness:\n1. The manuscript contains an LLM prompt artifact at Lines 218–219: “To combine the first two equations into one line and leave the third as its own line, use the following LaTeX code:”. \n\n2. There is an inconsistency in the reported number of organ categories. At Lines 715–718, the manuscript states that “we directly extract 15 key abdominal organs, including spleen, left kidney, right kidney, gallbladder, liver, stomach, pancreas, left adrenal gland, right adrenal gland, duodenum, small bowel, colon, urinary bladder, and prostate,” yet this list actually contains only 14 organ categories.\n\n3. The term “mask-free” may be overly strong. Although OQMSP does not require masks at inference time, the pretraining pipeline relies heavily on TotalSegmentator pseudo-labels, LLM-based organ-level text decomposition, and validation by radiologists. Therefore, a more accurate description would be inference-time mask-free rather than mask-free throughout the entire training pipeline.\n\n4. The computational advantages of the MoE design should be quantified more thoroughly. It would be helpful to report training/inference wall-clock time, FLOPs, memory consumption, and parameter-normalized performance.\n\n5. The fairness of the comparisons requires further clarification. A2MoE benefits from large-scale CT-report pretraining, organ pseudo-labels, and report decomposition, whereas it is not fully clear whether all baselines are provided with a comparable level of organ-level supervision. The paper should more explicitly disentangle architectural gains, pretraining data gains, and supervision pipeline gains.",
+ "quality": 2,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 3,
+ "questions": "1. How accurate is the histogram predicted by the presence head during inference? Have the authors evaluated the KL divergence or correlation between the predicted histogram and the pseudo-label histogram, and examined how errors in histogram prediction affect downstream performance?\n\n2. Does A2MoE compute all experts in every forward pass? If so, could the authors provide a comparison with SegMamba and Mamba-HoME in terms of FLOPs, memory consumption, and training/inference time?\n\n3. Is there any visualization or quantitative localization evaluation for the organ query attention in OQMSP? Do these queries consistently correspond to specific organs, or do they primarily function as latent slots?\n\n4. The report decomposition uses Qwen3-30B-A3B and is followed by radiologist verification. Does this manual verification cover the entire training set, or is it performed on a sampled subset? If the latter, how is the error rate estimated?",
+ "limitations": "yes",
+ "rating": 4,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "The manuscript contains an LLM prompt artifact at Lines 218–219: “To combine the first two equations into one line and leave the third as its own line, use the following LaTeX code:”.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The article mentions that some low-level errors in comparing LLM prompts and category descriptions have been resolved, and some training resource analysis has also been addressed."
+ },
+ "createdAt": "2026-07-14T08:42:46.145Z",
+ "modifiedAt": "2026-11-18T13:35:38.577Z",
+ "url": "https://openreview.net/forum?id=cOJs7gDYiz&noteId=JxgOz35jIU",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/cojs7gdyiz/notes/msitcbzc2y.json added

+++ b/reviews/openreview/cojs7gdyiz/notes/msitcbzc2y.json
@@ -0,0 +1,19 @@
+{
+ "schema": "review/1",
+ "id": "MSITCBZc2y",
+ "replyTo": null,
+ "kind": "decision",
+ "invitation": "Decision",
+ "signature": "Program Chairs",
+ "content": {
+ "title": "Paper Decision",
+ "decision": "Accept (poster)",
+ "comment": "",
+ "metareview": "The paper proposes A2MoE, a 3D medical vision-language pre-training framework that introduces anatomical priors directly into expert routing and organ-level image–text alignment. The reviewers view the problem as well motivated, and the two components proposed along with A2MoE, namely HRR and OQMSP, as reasonably original. These components were validated across segmentation, classification, and detection benchmarks. Moreover, the effects span CT, MRI, and ultrasound [isoH, bN4a, Jq6Y]. The main weakness is that it remains unclear how much of the improvement comes from the proposed anatomy-aware mechanisms rather than increased model capacity, large-scale pre-training, pseudo-label supervision, and report decomposition [isoH, bN4a]. The computational-efficiency claims are also insufficiently quantified, and the paper provides limited evidence that the predicted anatomy histogram and organ queries behave as intended [isoH]. The response should therefore prioritize controlled or parameter-normalized comparisons to alternative approaches, FLOPs/memory/runtime information, clarification of whether all experts are evaluated, and evidence on histogram accuracy and organ-query localization. Clarifying the PANORAMA metrics, “mask-free” terminology, report-verification procedure, notation issues, and please remove the artifact pointed by two reviewers [isoH, Jq6Y].",
+ "final_justification": "I would like to acknowledge that the reviewers and I read the responses offered by the authors. Based on reviewers' increased scores and my own analysis, most of the concerns raised in the reviews and the meta-review were sufficiently addressed. Taking this into account, I am confident in recommending this paper for acceptance."
+ },
+ "createdAt": "2026-09-24T11:16:53.621Z",
+ "modifiedAt": "2026-11-18T14:52:42.649Z",
+ "url": "https://openreview.net/forum?id=cOJs7gDYiz&noteId=MSITCBZc2y",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/cojs7gdyiz/notes/n5rn97pujr.json added

+++ b/reviews/openreview/cojs7gdyiz/notes/n5rn97pujr.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "n5rN97pujr",
+ "replyTo": "9T1xMmRiSj",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "We thank the reviewer for a constructive review that identifies concrete, actionable improvements. \n\n> **W1, Q1: [...] the methodology section 3 could use a round of revision [..]**\n\nWe agree with reviewer. We have thoroughly revised Section 3 to ensure full mathematical rigor and clarity regarding Section 3 in revised manuscript. The following inconsistencies have been fixed:\n\n- **$C$ vs. $C_s$:** $C$ now denotes only the number of anatomical classes. The stage channel width has been renamed to $D_s$ (formerly $C_s$), eliminating the notation conflict.\n\n- **Batch index $b$:** All equations are now presented for a single sample, with the batching convention stated once at the beginning of Section 3. The stray $h_{b,c}$ in Equation 3 no longer includes an explicit batch index.\n\n- **Stage index $s$:** Stage indices are now used consistently as **subscripts** (like $\\mathbf{X}\\_s$, $\\mathbf{A}\\_s$, $\\Psi_{\\text{gate}, s}$). Mixed subscript/superscript notation has been removed.\n\n- **$\\mathbf{s}_{(s)}$:** The stage embedding has been renamed to $\\mathbf{g}_s$, eliminating the self-indexed symbol notation.\n\nWe believe these changes make Section 3 substantially easier to follow and let the reader focus on the method.\n\n\n\n> **W2, Q3 (bonus): Backbone generality**\n\n\nWe sincerely thank the reviewer for this insightful suggestion. We agree that discussing how our proposed framework (A$^{2}$MoE + OQMSP) generalizes across different architectural backbones, such as Vision Transformers (Swin UNETR) vs. State Space Models (SegMamba), substantially broadens the scope and impact of our paper. We have strengthened it in two ways.\n\n1. Architecturally, A$^{2}$MoE is a drop-in substitution requiring no backbone-specific change: the A$^{2}$MoE layer replaces the per-stage channel MLP — a 1$\\times$1$\\times$1-convolution feed-forward block present in essentially every 3D encoder — and OQMSP uses an arbitrary multi-scale pyramid, parameterised only by per-stage channel widths and key/value strides. Neither component assumes anything about the token-mixing operator (state-space, attention or convolution). This is now stated explicitly in Sec. 3.3 in revised manuscript.\n\n2. Empirically, we substituted the *SegMamba backbone* with the *Swin UNETR backbone* and re-ran on the downstream segmentation task for several datasets, including AMOS-CT, PANORAMA, AMOS-MRI, GEPAR3D, MRISegmenter and MVSeg. \n\n\n| Configuration | Params | VRAM | AMOS-CT | PANORAMA | AMOS-MRI | GEPAR3D | MRISegmenter | MVSeg |\n| :------------ | :--: | :--: | :--: | :--: | :--: | :--: | :--: |:--: |\n| | M | G | DSC (HD95) | DSC (HD95) | DSC (HD95) | DSC (HD95) | DSC (HD95) | DSC (HD95)|\n| Swin UNETR | 62.2 | 4.4 | 83.8 (28.4) | 73.8 (10.2) | 74.6 (14.5) | 83.2 (12.4) | 72.1 (8.7) | 81.9 (7.2) |\n| + A$^{2}$MoE | 76.2| 4.5 | 83.9 (9.2) | 76.1 (8.4) | 76.8 (13.8) | 84.5 (9.8) | 75.4 (7.6) | 82.8 (5.6) |\n| + OQMSP | 80.2 | 4.6 | 87.2 (7.5) | 77.3 (6.9) | 80.2 (10.3) | 86.2 (9.2) | 77.5 (6.3) | 83.9 (4.9) |\n| | | | | | |\n| SegMamba | 65.5 | 2.9 | 85.5 (26.1) | 76.0 (8.6) | 76.7 (9.3) | 85.3 (10.6) | 74.5 (6.8) | 83.8 (5.8) |\n| + A$^{2}$MoE |79.5 | 3.0 | 87.5 (7.6) | 78.2 (7.1) | 78.5 (12.2) | 86.1 (7.9) | 77.6 (5.9) | 84.5 (4.4) |\n| + OQMSP | 83.5 | 3.1 | 88.7 (6.2) | 79.1 (5.8) | 82.3 (8.9) | 87.7 (8.1) | 79.8 (5.5) | 85.4 (4.0) |\n\n\nWe demonstrated that our proposed key modules, A$^{2}$MoE and OQMSP, consistently improve performance across different backbones.\n\n> **W3, Q2: Focus on PANORAMA and include the validation on the challenge metrics [...]**\n\nFollowing the PANORAMA challenge paper [1], we fine-tuned each configuration with the training cohort from the Netherlands (RUMC, Nijmegen and UMCG, Groningen). Because the official test set is not available, we extracted data from two independent sets (NIH, USA, and MSD, USA) to test our performance. Additionally, we used in-house dataset with $N=60$ PDAC cases with voxel-wise annotation masks provided by experienced radiologists to demonstrate generalizability.\n\nAs previously, we provided DSC and HD95 metrics, we incorporate metrics used in PANORAMA challenge, including AUROC and AP.\n\n| Method | DSC (%) | HD95 (mm) | AUROC | AP |\n|------------------|:------------------:|:----------------------:|:------------------:|:------------------:|\n| VoCo | 71.6 | 16.9 | 0.824 | 0.582 |\n| uC 3DU-Net | 76.6 | 4.7 | 0.878 | 0.638 |\n| SuPreM | 76.6 | 4.7 | 0.876 | 0.635 |\n| SegMamba | 76.0 | 8.6 | 0.865 | 0.618 |\n| Mamba-HoME | 77.5 | 4.8 | 0.889 | 0.655 |\n| Merlin | 77.5 | 9.4 | 0.892 | 0.660 |\n| fVLM | 76.8 | 9.8 | 0.871 | 0.627 |\n| BTB3D | 77.3 | 9.2 | 0.890 | 0.685 |\n| **Ours** | **79.1** | **5.8** | **0.918** | **0.702** |\n\n\nWe demonstrated that our proposed method outperformed state-of-the-art methods across several metrics, both in terms of segmentation quality and PANORAMA challenge-based AUROC and AP.\n\n\nReferences:\n\n[1] Alves, Natalia, et al. \"Artificial intelligence and radiologists in pancreatic cancer detection using standard of care CT scans (PANORAMA): an international, paired, non-inferiority, confirmatory, observational study.\" The Lancet Oncology (2025).\n\n\nWe hope this addresses all concerns. Should any further questions arise, we remain fully available throughout the discussion period. In light of this rebuttal, we kindly ask the reviewer to consider increasing their score."
+ },
+ "createdAt": "2026-07-28T09:04:45.818Z",
+ "modifiedAt": "2026-11-18T17:11:24.915Z",
+ "url": "https://openreview.net/forum?id=cOJs7gDYiz&noteId=n5rN97pujr",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/cojs7gdyiz/notes/txskznfykj.json added

+++ b/reviews/openreview/cojs7gdyiz/notes/txskznfykj.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "TXSkZnfykj",
+ "replyTo": "JxgOz35jIU",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "We thank the reviewer for the positive assessment. We appreciate the constructive comments regarding terminology, computational analysis, and further validation of the proposed components. We address each point below.\n\n> **W1: LLM prompt arficact**\n\nThank you for catching this. The sentence \"To combine the first two equations into one line and leave the third as its own line, use the following LaTeX code:\" was introduced while formatting the OQMSP equation block. It has been deleted in revised manuscript.\n\n> **W2: There is an inconsistency in the reported number of organ categories [...]**\n\nThe intended number is 14 foreground organs. The enumerated list in the text is the correct one; the count and the table were wrong. In Table 4 we removed the *Esophagus* row and renumbered classes 10–14, giving background + 14 organs.\n\n> **W3: The term “mask-free” may be overly strong [...]**\n\nWe agree, and have adopted \"inference-time mask-free\" consistently in revised manuscript. We have also added one sentence to the limitations noting that the pre-training pipeline does depend on pseudo-labels and LLM decomposition.\n\n> **W4: The computational advantages of the MoE design should be quantified more thoroughly [...]**\n\nWe have measured all compared methods under a matched protocol and will include the following table in the revised manuscript as requested.\n\n| Method | GFLOPs | VRAM (G) | Training time (patches/s)$^\\dagger$ | Inference time (s/scan)$^\\ddagger$ |\n|:------:|:------:|:-------:|:-------:|:-------:|\n| VoCo | 1850 | 4.4 | 2.1 | 3.8 |\n| uC3DUNet | 1110 | 3.1 | 4.1 | 2.2 |\n| SuPreM | 1960 | 4.4 | 2.0 | 3.9 |\n| Mamba-HoME | 1610 | 3.7 | 2.3 | 3.0 |\n| Merlin | 2400 | 13.8 | 1.0 | 7.5 |\n| fVLM | 1600 | 4.5 | 2.2 | 3.8 |\n| BTB3D | 1620 | 7.6 | 1.6 | 5.2 |\n| SegMamba | 1560 | 2.9 | 3.4 | 2.6 |\n| A$^{2}$MoE | 1630 | 3.0 | 3.0 | 2.8 |\n\n$\\dagger$ Means the number of patches in 128 $\\times$ 128 $\\times$ 128 resolution per second on $N=160$ CT scans from AMOS-CT training set, with a batch size $B=1$.\n$\\ddagger$ Means the average second per scan on $N=100$ CT scans from AMOS-CT test set. Please note, for test we used their original resolution.\n\n**Parameter-normalized performance.** The accuracy gains of A$^{2}$MoE over SegMamba (e.g. AMOS-CT 85.5 $\\rightarrow$ 87.5 DSC) are obtained with only ~+4–7% FLOPs and +0.1 GB VRAM, whereas larger models such as Mamba-HoME and Merlin do not surpass A$^{2}$MoE on this compute–accuracy trade-off. All methods were evaluated on the AMOS-CT test set at full resolution using single A100 80GB.\n\n> **W5: The fairness of the comparisons requires further clarification [...]**\n\nWe agree it should be stated more explicitly. Our experimental design already separates these factors; we clarify the protocol below and will make it prominent in Sections 4.1–4.2 and the Table 1 caption. In original submission (Table 1), $\\dagger$ denotes models initialized from pre-trained weights (released checkpoints for external methods; our own CT–report pre-trained weights for A$^{2}$MoE and OQMSP #3).\n\n**Modality-matched supervision in our pre-training.** For A$^{2}$MoE, pre-training uses CT scans + pseudo-labels for anatomy-conditioned routing/segmentation objectives, and additionally organ-level report decomposition for OQMSP image–text alignment. Segmentation-oriented baselines that admit dense label supervision are trained with CT scans + pseudo-labels under the same experimental settings; VLM baselines that require text features use CT + pseudo-labels + reports in their original pre-training.\n\nAdditionally, we did ablation studies on classification and detection downstream tasks to demonstrate the gain of performance provided by each key architecture component. We kindly refer to **W2 [bN4a]**. We will clarify it in camera-ready version.\n\n> **Q1: How accurate is the histogram predicted by the presence head during inference? [...]**\n\nWe evaluate the presence head on the **AMOS-CT test set** by comparing the inference-time prediction $\\hat{\\mathbf{h}}=\\operatorname{softmax}(\\Psi_{\\mathrm{pres}}(\\mathbf{v}_s))$ to the crop-level pseudo-label histogram $\\mathbf{h}$ computed from the ground-truth masks.\n\nAcross AMOS-CT test crops we obtain mean $\\mathrm{KL}(\\mathbf{h}\\,\\|\\,\\hat{\\mathbf{h}})=0.22$ and mean per-class Pearson correlation $r=0.82$. Treating histogram mass as an organ-presence score, binary AUROC is approximately $0.92$ for large organs (liver, spleen, kidneys, stomach) and $0.76$ for small or thin structures (adrenal glands, duodenum, gallbladder). Errors concentrate on low-prevalence classes whose absolute voxel fraction is small; background-dominated crops inflate absolute KL less than they hurt small-organ calibration.\n\n**Effect on downstream segmentation.** To measure how histogram error propagates, we compare three routing settings at identical parameter count on AMOS-CT:\n\n| Inference routing| DSC (%) |\n|-----|:-----:|\n| Uniform (average all experts equally) |86.1| \n| Presence head $\\hat{\\mathbf{h}}$ (this work) |88.7| \n| Oracle GT ($\\mathbf{h}$ from the GT on the test crop) |89.5|\n\nAnatomy-conditioned routing with the predicted histogram improves over the uniform control by $+2.6$ DSC.\nReplacing $\\hat{\\mathbf{h}}$ by the oracle histogram yields an additional $0.8$ DSC. Thus presence-head errors are not negligible, but they account for only part of the HRR gain: most of the benefit of anatomy-aware routing remains under\nrealistic histogram prediction. We will report per-organ KL/correlation and this uniform--predicted--oracle bracket in the revised manuscript.\n\n> **Q2: Does A2MoE compute all experts in every forward pass? [...]**\n\nYes, A$^{2}$MoE is based on soft MoE, as described in Preliminaries (see Appendix) and computes all experts in every forward pass. Here, we provide a comparison with SegMamba and Mamba-HoME in terms of FLOPs, memory consumption, training and inference time.\n\n| Method | GFLOPs | VRAM (G) | Training time (patches/s)$^\\dagger$ | Inference time (s/scan)$^\\ddagger$ |\n|:------:|:------:|:--------:|:-------:|:--------:|\n| SegMamba | 1560 | 2.9 | 3.4 | 2.6 |\n| Mamba-HoME | 1610 | 3.7 | 2.3 | 3.0 |\n| A$^{2}$MoE | 1630 | 3.0 | 3.0 | 2.8 |\n\nFor the definitions of $\\dagger$ and $\\ddagger$, please refer to **W4**.\n\n> **Q3: Is there any visualization or quantitative localization evaluation for the organ query attention in OQMSP? [...]**\n\nOQMSP uses one learnable query per non-background organ (14 queries), shared across all pyramid stages. Soft localization maps are given by $\\text{softmax}(\\tilde{Q}^s {K^s}^\\top)$ at each stage; we upsample them to the label grid, fuse stages with the learned scale weights, and compare against organ pseudo-masks on the validation set.\n\nFor organ query $q \\in \\{1,\\dots,C-1\\}$ and sample $b$, let $\\alpha_{b,q}(j)$ denote the fused OQMSP attention map after multi-scale aggregation and upsampling to the label grid $\\Omega$, normalized as a spatial distribution:\n\n$$\\alpha_{b,q}(j)\\ge 0, \\qquad \\sum_{j\\in\\Omega}\\alpha_{b,q}(j)=1.$$ Let $L_b(j)\\in\\{0,1,\\dots,C-1\\}$ be the voxel-wise organ label (with $0$ denoting background), and define the ground-truth mask of organ $q$ as $M_{b,q} = \\{ j \\in \\Omega : L_b(j) = q \\}$. When attention maps are produced at multiple encoder stages $s\\in\\{1,\\dots,4\\}$, we form the fused map: $$\\alpha_{b,q} = \\sum_{s=1}^{4} \\alpha_s\\, \\mathcal{U}\\!\\bigl(\\alpha^{(s)}_{b,q}\\bigr),$$\n\nwhere ${\\alpha}=\\operatorname{softmax}(\\alpha_1,\\dots,\\alpha_4)$ are the learned OQMSP scale weights and $\\mathcal{U}$ upsamples to $\\Omega$, followed by re-normalization so that $\\sum_{j}\\alpha_{b,q}(j)=1$.\n\nWe report pointing-game accuracy, whether the attention peak falls inside the target organ. We take the peak location of query $q$ as: $$j^{\\star}\\_{b,q} = \\arg\\max_{j\\in\\Omega}\\,\\alpha_{b,q}(j).$$\n\nA prediction is counted as correct if the peak falls inside the matched organ:\n\n$$\\mathrm{PG}\\_b,q = \\mathbf{1}\\bigl[j^{\\star}\\_b,q \\in M\\_b,q\\bigr] = \\mathbf{1}\\bigl[L\\_b(j^{\\star}\\_b,q)=q\\bigr].$$ \n\nLet $B_q=\\{b : |M_{b,q}|>0\\}$ be the set of samples in which organ $q$ is present. The per-organ and mean pointing-game scores are:\n\n$$\\mathrm{PG}\\_q = \\frac{1}{|B\\_q|} \\sum\\_b\\in B\\_q \\mathrm{PG}\\_{b,q}, \\qquad \\mathrm{PG} = \\frac{1}{C-1} \\sum\\_q=1^{C-1} \\mathrm{PG}\\_q.$$\n\n| Organ | Pointing (%) |\n|:-----|:-----:|\n| Liver | 88 |\n| Spleen | 84 |\n| Kidney left | 80 |\n| Kidney right | 78 |\n| Stomach | 76 |\n| Colon | 74 |\n| Bladder | 72 |\n| Pancreas | 70 |\n| Prostate | 68 |\n| Gallbladder | 62 |\n| Small bowel | 58 |\n| Duodenum | 55 |\n| Adrenal gland left | 50 |\n| Adrenal gland right | 48 |\n\n**Organ-specific queries vs. latent slots.** Mean pointing ~69% indicate that queries consistently correspond to fixed organ identities rather than unrestricted latent slots. Residual confusion is structured and clinically expected: kidneys, adrenal glands, and adjacent GI pairs (e.g. pancreas–duodenum, bowel–colon), rather than arbitrary cross-organ mixing. In camera-ready version, we will provide attention-map visualizations showing organ-consistent localization.\n\n> **Q4: The report decomposition uses Qwen3-30B-A3B and is followed by radiologist verification. Does this manual verification cover the entire training set, or is it performed on a sampled subset? [...]**\n\nWe verified all pre-training studies using a custom interface displaying source reports alongside extracted snippets. Four radiologists (≥5 years experience) reviewed every organ-level snippet with single-action accept/edit/reject, while a senior radiologist (>30 years experience) adjudicated disputed cases. We will release these snippets for the public Merlin subset to support research and update the manuscript accordingly.\n\nWe hope this addresses all concerns. Should any further questions arise, we remain fully available throughout the discussion period. In light of this rebuttal, we kindly ask the reviewer to consider increasing their score."
+ },
+ "createdAt": "2026-07-28T10:12:19.761Z",
+ "modifiedAt": "2026-11-18T17:11:25.072Z",
+ "url": "https://openreview.net/forum?id=cOJs7gDYiz&noteId=TXSkZnfykj",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/cojs7gdyiz/submission.json added

+++ b/reviews/openreview/cojs7gdyiz/submission.json
@@ -0,0 +1,12 @@
+{
+ "schema": "submission/1",
+ "id": "cOJs7gDYiz",
+ "venue": {
+ "id": "NeurIPS.cc/2026/Conference",
+ "name": "NeurIPS 2026",
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"
+ },
+ "number": 4021,
+ "url": "https://openreview.net/forum?id=cOJs7gDYiz",
+ "license": "CC-BY-4.0"
+}

versions/v_dddxzkqs.json added

+++ b/versions/v_dddxzkqs.json
@@ -0,0 +1,22 @@
+{
+ "date": "2026-04-22",
+ "kind": "submitted",
+ "label": "NeurIPS 2026",
+ "submissions": [
+ {
+ "venue": "NeurIPS 2026",
+ "status": "accepted",
+ "decision": "Accept (poster)",
+ "number": 4021,
+ "url": "https://openreview.net/forum?id=cOJs7gDYiz",
+ "reviews": "openreview/cojs7gdyiz",
+ "evidence": [
+ "https://openreview.net/forum?id=cOJs7gDYiz"
+ ]
+ }
+ ],
+ "url": "https://openreview.net/forum?id=cOJs7gDYiz",
+ "evidence": [
+ "https://openreview.net/forum?id=cOJs7gDYiz"
+ ]
+}