SAFE-SVD: Sensitivity-Aware Fidelity-Enforcing SVD for Physics Foundation Models
Import NeurIPS 2026 submission R2w60GCpGv: 8 notes
@openreview[bot] · 2026-11-22 17:56 UTC · e2cfee495ea8 ·
reviews/openreview/r2w60gcpgv/forms.json added
+++ b/reviews/openreview/r2w60gcpgv/forms.json@@ -0,0 +1,227 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ },+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "quality",+ "clarity",+ "significance",+ "originality"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 6+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 5+ },+ {+ "key": "quality",+ "label": "Quality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "clarity",+ "label": "Clarity",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "significance",+ "label": "Significance",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "originality",+ "label": "Originality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "contribution_type",+ "label": "Contribution type",+ "type": "choice"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "strengths_and_weaknesses",+ "label": "Strengths and weaknesses",+ "type": "text"+ },+ {+ "key": "questions",+ "label": "Questions",+ "type": "text"+ },+ {+ "key": "limitations",+ "label": "Limitations",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ },+ {+ "key": "paper_formatting_concerns",+ "label": "Formatting concerns",+ "type": "text"+ },+ {+ "key": "ethical_concerns",+ "label": "Ethical concerns",+ "type": "choice"+ },+ {+ "key": "code_of_conduct_acknowledgement",+ "label": "Code of conduct",+ "hidden": true+ },+ {+ "key": "responsible_reviewing_acknowledgement",+ "label": "Responsible reviewing",+ "hidden": true+ }+ ]+ },+ "Rebuttal": {+ "label": "Rebuttal",+ "fields": [+ {+ "key": "rebuttal",+ "label": "Rebuttal",+ "type": "text"+ }+ ]+ },+ "Ethics_Review": {+ "label": "Ethics review",+ "fields": [+ {+ "key": "scope_of_ethics_concerns",+ "label": "Scope",+ "type": "choice"+ },+ {+ "key": "ethics_review",+ "label": "Ethics review",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/r2w60gcpgv/notes/3ftobe4cmu.json added
+++ b/reviews/openreview/r2w60gcpgv/notes/3ftobe4cmu.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "3FTObe4CmU",+ "replyTo": "oG227efU6g",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "We thank the reviewers for their helpful and constructive feedback. Our responses are provided below.\n\n**Weakness 1.1: if there is any metric saturation anywhere or some data leakage.**\n\n**Weakness 1.2: Is there a way to compare the true loss values or to find the difference between predicted fields?**\n\nThere is neither metric saturation nor data leakage. To verify the near-zero degradation, we report the raw loss values from Tables 2 and 4 to six decimal places (approximately $10^{-6}$), an accuracy used to evaluate PDE surrogate models.\n\n### **Table: Raw Loss on Poseidon.**\n\n| Ratio | Method | Size | NS-PwC Base Loss ↓ | NS-PwC Sobolev ↓ | NS-PwC Div-Free ↓ | NS-PwC Vorticity ↓ | CE-RM Base Loss ↓ | CE-RM Sobolev ↓ | Wave-Gauss Base Loss ↓ | Wave-Gauss Sobolev ↓ |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 1.0 | Origin | 628.6M | 0.002346 | 5.283677 | 0.022443 | 0.074452 | 0.675398 | 1806.582118 | 0.053786 | 5710.175821 |\n| 0.8 | ASVD | 502.9M | 0.049272 | 52.020897 | 0.134364 | 1.180818 | 0.736271 | 1775.958009 | 0.097812 | 67969.314153 |\n| 0.8 | FWSVD | 502.7M | 0.164924 | 125.534797 | 0.324314 | 2.797029 | 0.815371 | 2006.244402 | 0.354795 | 107290.637846 |\n| 0.8 | SVD-LLM V2 | 524.2M | 0.163070 | 99.393721 | 0.269726 | 2.755940 | 0.829463 | 1779.526832 | 0.353159 | 77425.422663 |\n| 0.8 | Dobi-SVD | 503.7M | 0.189102 | 119.586527 | 0.310397 | 2.895996 | 0.906149 | 1708.748682 | 0.394176 | 131465.388561 |\n| 0.8 | SAES-SVD | 502.7M | 0.063724 | 92.646709 | 0.350908 | 1.317932 | 0.682649 | 1863.292494 | 0.177435 | 144908.644544 |\n| 0.8 | **Ours** | **503.0M** | **0.002346** | **5.283680** | **0.022443** | **0.074453** | **0.675398** | **1806.582191** | **0.053786** | **5710.177416** |\n| 0.6 | ASVD | 376.9M | 0.107813 | 146.883963 | 0.475111 | 2.162998 | 0.846900 | 2014.990735 | 0.243183 | 359863.704893 |\n| 0.6 | FWSVD | 377.1M | 0.169476 | 162.570272 | 0.403986 | 2.849220 | 0.832359 | 2420.457445 | 0.360187 | 143636.075134 |\n| 0.6 | SVD-LLM V2 | 438.3M | 0.167446 | 134.674022 | 0.355126 | 2.792542 | 0.856292 | 2343.076295 | 0.363791 | 290164.448727 |\n| 0.6 | Dobi-SVD | 378.1M | 0.177542 | 165.708592 | 0.502048 | 2.843103 | 0.916546 | 3038.127578 | 0.408015 | 531636.800308 |\n| 0.6 | SAES-SVD | 377.1M | 0.069950 | 98.428941 | 0.375246 | 1.461335 | 0.690163 | 2017.772529 | 0.175208 | 197206.586203 |\n| 0.6 | **Ours** | **377.5M** | **0.002346** | **5.283981** | **0.022444** | **0.074461** | **0.675424** | **1806.623425** | **0.053787** | **5710.564509** |\n| 0.4 | ASVD | 251.4M | 0.123614 | 235.851025 | 0.644856 | 2.539356 | 0.905710 | 2457.461326 | 0.309490 | 837808.684336 |\n| 0.4 | FWSVD | 251.5M | 0.186414 | 273.718787 | 0.571973 | 3.023241 | 0.866756 | 3205.293762 | 0.370103 | 207990.694653 |\n| 0.4 | SVD-LLM V2 | 374.9M | 0.207411 | 324.980443 | 1.039043 | 3.149890 | 0.917661 | 4020.915788 | 0.406619 | 1126462.928486 |\n| 0.4 | Dobi-SVD | 252.6M | 0.201320 | 280.343788 | 0.630363 | 3.088124 | 0.940614 | 3039.797453 | 0.414363 | 605116.041955 |\n| 0.4 | SAES-SVD | 251.5M | 0.074184 | 103.977274 | 0.388625 | 1.538947 | 0.698797 | 2140.966148 | 0.187863 | 235236.426873 |\n| 0.4 | **Ours** | **251.9M** | **0.002352** | **5.287955** | **0.022449** | **0.074575** | **0.675486** | **1807.712289** | **0.053809** | **5733.039429** |\n| 0.2 | ASVD | 125.8M | 0.160122 | 331.959944 | 0.822106 | 3.177137 | 0.952436 | 5117.550250 | 0.336182 | 748449.058025 |\n| 0.2 | FWSVD | 125.9M | 0.204614 | 409.462459 | 0.868615 | 3.258385 | 0.949415 | 5870.619010 | 0.406130 | 659618.391958 |\n| 0.2 | SVD-LLM V2 | 353.2M | 0.225889 | 322.909589 | 0.961130 | 3.375724 | 1.090368 | 4435.062763 | 0.657377 | 1140022.617962 |\n| 0.2 | Dobi-SVD | 127.0M | 0.208188 | 538.432974 | 1.144440 | 3.380004 | 0.977861 | 3164.483965 | 0.445664 | 1154844.295247 |\n| 0.2 | SAES-SVD | 125.9M | 0.089766 | 133.638471 | 0.515947 | 1.880708 | 0.717621 | 2261.100429 | 0.251106 | 341074.854198 |\n| 0.2 | **Ours** | **126.3M** | **0.002408** | **5.378459** | **0.022559** | **0.075455** | **0.676077** | **1841.961242** | **0.054164** | **14385.645167** |\n\nIn all experiments, the training-calibration-testing split follows exactly the protocols in Poseidon, VICON, and MPP. Therefore, the calibration and evaluation sets are strictly separated, as described in Appendix C.1 and C.2. We will also release the code to support reproducibility.\n\n**Weakness 1.3: if the experiments are averaged across multiple runs or from single run.** \n\n**Question 1: Report experiments for multiple runs and also provide some error bars for the results.**\n\nThe experiments are based on a single run because the results are deterministic when the calibration dataset is fixed. Due to the space limit, please refer to our response to Reviewer XM4x, W1, for detailed report.\n\n**Weakness 2: Section 4.1 and Table 1 have some differences in the results reported.** \n\nThanks for pointing out this inconsistency. We will modify it.\n\n**Weakness 3: The paper uses L2 norm for the loss and objective functions in Section 3.1 but the paper discusses results only on L1 norm in the experiments.**\n\nThere is no inconsistency between theory and experiments. The experimental L1 norm refers to the L1 Sobolev loss, which is part of $L$ in Equation 4. The L2 norm in Equation 4 comes from Equation 2 and has never been an L1 norm.\n\n**Weakness 4.1: clarify why L1 outperforms L2.**\n\nEmpirically, we find that the L1 Sobolev loss performs better because compression-induced derivative errors can be large at a few locations. Compared with L1 Sobolev Loss, the L2 Sobolev loss is more sensitive to these outliers, biasing the compression towards these outliers and giving overall worse accuracy.\n\n**Weakness 4.2: re-derivations for L1.** \n\nThe choice between an $L\\_1$ and an $L\\_2$ Sobolev loss does not change the derivation of our final objective. Following BRECQ, the difference between the compressed-model loss and the original-model loss can be approximated using a second-order Taylor expansion:\n\n$$ \\\\Delta\\\\mathcal{L}=\\\\mathcal{L}(\\\\mathbf{W}+\\\\Delta\\\\mathbf{W})-\\\\mathcal{L}(\\\\mathbf{W})\\\\approx\\\\mathbf{g}\\_{W}^{\\\\top}\\\\Delta\\\\mathbf{W}+\\\\frac{1}{2}\\\\Delta\\\\mathbf{W}^{\\\\top}\\\\mathbf{H}\\_{W}\\\\Delta\\\\mathbf{W}, $$\n\nwhere $\\\\mathcal{L}$ does not prescribe a specific form. In our setting, $\\\\mathcal{L}$ includes the Sobolev loss, which may use either an $L\\_1$ or an $L\\_2$ criterion. Following the BRECQ assumption that the pretrained model is sufficiently well trained, the expected first-order term is negligible, leading to\n\n$$ \\\\min\\_{\\\\Delta\\\\mathbf{W}}\\\\mathbb{E}[\\\\Delta\\\\mathcal{L}]\\\\approx\\\\min\\_{\\\\Delta\\\\mathbf{W}}\\\\frac{1}{2}\\\\mathbb{E}\\\\left[\\\\Delta\\\\mathbf{W}^{\\\\top}\\\\mathbf{H}\\_{W}\\\\Delta\\\\mathbf{W}\\\\right]. $$\n\nUnder local linearization, $\\\\Delta\\\\mathbf{Z}\\\\approx\\\\mathbf{J}\\_{Z}\\\\Delta\\\\mathbf{W}$ and $\\\\mathbf{H}\\_{W}\\\\approx\\\\mathbf{J}\\_{Z}^{\\\\top}\\\\mathbf{H}\\_{Z}\\\\mathbf{J}\\_{Z}$, yielding $\\\\Delta\\\\mathbf{W}^{\\\\top}\\\\mathbf{H}\\_{W}\\\\Delta\\\\mathbf{W}\\\\approx\\\\Delta\\\\mathbf{Z}^{\\\\top}\\\\mathbf{H}\\_{Z}\\\\Delta\\\\mathbf{Z}$. Approximating $\\\\mathbf{H}\\_{Z}$ using the Fisher information matrix then yields our Equation 1. This approximation interprets the objective as a composite log-likelihood, where the $L\\_1$ and $L\\_2$ terms correspond to Laplace and Gaussian distributions, respectively. We will clarify.\n\n**Question 2: Show results for L2 norm as well to compare with the L1 norm results in the experiments?** \n\nWe provide the L2 norm Sobolev Loss results on Poseidon, VICON and MPP.\n\n### **Table: Poseidon**\n\n| Ratio | Method | Size | NS-PwC: Base Loss ↓ | NS-PwC: Sobolev ↓ | NS-PwC: Div-Free ↓ | NS-PwC: Vorticity ↓ | CE-RM: Base Loss ↓ | CE-RM: Sobolev ↓ | Wave-Gauss: Base Loss ↓ | Wave-Gauss: Sobolev ↓ |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 1.0 | Origin | 628.6M | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% |\n| 0.8 | Ours | 503.0M | 0.02% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 2.55% | 0.34% |\n| 0.6 | Ours | 377.5M | 0.01% | 0.01% | 0.01% | 0.01% | 0.00% | 0.01% | 2.27% | 157.5% |\n| 0.4 | Ours | 251.9M | 0.73% | 3.39% | 0.83% | 0.34% | 0.00% | 0.70% | 2.09% | 1923% |\n| 0.2 | Ours | 126.3M | 58.04% | 224.2% | 119.0% | 30.76% | 1.04% | 18.54% | 33.04% | 10547% |\n\n### **Table: VICON**\n\n| Ratio | Method | Size | NS-2D: Base Loss ↓ | NS-2D: Sobolev ↓ | NS-2D: Div-Free ↓ | NS-2D: Vorticity ↓ | Comp-2D: Base Loss ↓ | Comp-2D: Sobolev ↓ | Euler-2D: Base Loss ↓ | Euler-2D: Sobolev ↓ |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 1.0 | Origin | 87.8M | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% |\n| 0.8 | Ours | 70.3M | 0.42% | 0.17% | 0.05% | 0.21% | 1.46% | 0.81% | 0.20% | 0.00% |\n| 0.6 | Ours | 52.8M | 7.83% | 2.32% | 0.43% | 4.56% | 16.24% | 11.73% | 4.59% | 0.79% |\n| 0.4 | Ours | 35.3M | 34.36% | 7.50% | 1.93% | 18.29% | 97.59% | 35.44% | 27.54% | 3.61% |\n| 0.2 | Ours | 17.8M | 330.1% | 28.92% | 11.13% | 107.1% | 782.9% | 126.0% | 274.8% | 18.20% |\n\n### **Table: MPP**\n\n| Ratio | Method | Size | IncompNS: Base Loss ↓ | IncompNS: Sobolev ↓ | IncompNS: Div-Free ↓ | IncompNS: Vorticity ↓ | CompNS: Base Loss ↓ | CompNS: Sobolev ↓ | DiffRe-2D: Base Loss ↓ | DiffRe-2D: Sobolev ↓ | SWE: Base Loss ↓ | SWE: Sobolev ↓ |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 1.0 | Origin | 407.1M | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% |\n| 0.8 | Ours | 366.8M | 17.81% | 1.78% | 0.09% | 3.23% | 0.24% | 0.02% | 3.72% | 0.82% | 21.57% | 2.54% |\n| 0.6 | Ours | 326.5M | 100.8% | 10.20% | 0.28% | 19.33% | 3.55% | 0.40% | 18.42% | 3.28% | 82.32% | 10.09% |\n| 0.4 | Ours | 286.3M | 422.2% | 38.31% | 0.68% | 67.53% | 18.84% | 2.38% | 78.80% | 12.04% | 289.1% | 37.13% |\n| 0.2 | Ours | 246.0M | 1851% | 124.3% | 1.90% | 183.6% | 152.3% | 14.01% | 354.9% | 45.89% | 1215% | 131.4% |"+ },+ "createdAt": "2026-07-28T10:58:15.504Z",+ "modifiedAt": "2026-11-18T17:11:30.700Z",+ "url": "https://openreview.net/forum?id=R2w60GCpGv¬eId=3FTObe4CmU",+ "license": "CC-BY-4.0"+}
reviews/openreview/r2w60gcpgv/notes/3rayg6kwpt.json added
+++ b/reviews/openreview/r2w60gcpgv/notes/3rayg6kwpt.json@@ -0,0 +1,19 @@+{+ "schema": "review/1",+ "id": "3raYg6KWPt",+ "replyTo": null,+ "kind": "decision",+ "invitation": "Decision",+ "signature": "Program Chairs",+ "content": {+ "title": "Paper Decision",+ "decision": "Accept (poster)",+ "comment": "",+ "metareview": "The paper presents a technically interesting post-training SVD compression method for physics foundation models, with broad evaluation across three model families and multiple PDE settings. I view the submission as **needing clarification**, with the following prioritized issues. \n\n1. **Reliability of the central empirical results.** As raised by Reviewers SeTW and XM4x, SAFE-SVD shows almost no degradation in several Poseidon settings while competing methods degrade by orders of magnitude. Please provide raw, unrounded losses in addition to relative percentages; clearly confirm calibration/test separation; explain the baseline adaptations and the differing final model sizes; and state whether the results are deterministic or sensitive to calibration-subset selection. This is important for excluding metric-scaling or evaluation artifacts.\n\n2. **Meaning of “physical fidelity.”** As noted by Reviewer XM4x, the method uses a Sobolev-augmented loss for sensitivity estimation and is then evaluated substantially through Sobolev error. Independent constraint-based evidence is mainly provided for incompressible Navier–Stokes. Please clarify which claims are supported across the other PDE families and narrow “physical fidelity” to derivative fidelity where conservation or constraint metrics are unavailable.\n\n3. **Theory–implementation alignment.** Please address Reviewer SeTW’s concern by distinguishing the quadratic activation-space surrogate used for the SVD derivation from the L1 Sobolev loss used to compute sensitivity. Also state the assumptions underlying the Fisher/Gauss–Newton approximation and omission of the first-order Taylor term.\n\n4. **Compression definition.** As requested by Reviewer pbxu, define precisely what ratios such as 0.2, 0.4, and 0.6 retain, explain why model sizes differ across methods at the same reported ratio, and distinguish parameter reduction from demonstrated memory or latency improvements.\n\nMinor presentation inconsistencies are not decision-critical, and extensive new experiments are not required during rebuttal; clarification using existing results or appropriately narrowed claims would suffice. If these issues are resolved convincingly, I would be inclined to support acceptance, subject to the final discussion.",+ "final_justification": "After considering the rebuttal and reviewer discussion, I recommend to **accept**. The paper addresses an underexplored and practically relevant problem with a technically sound method and broad evaluation across multiple PFM families and PDE settings. The rebuttal substantially resolves the main concerns: the corrected multi-run and calibration analyses continue to support the empirical gains, while the additional physical-consistency evaluations and clarifications strengthen the central claims. Overall, the remaining limitations do not outweigh the technical contribution and empirical evidence."+ },+ "createdAt": "2026-09-24T11:17:00.713Z",+ "modifiedAt": "2026-11-18T14:52:47.334Z",+ "url": "https://openreview.net/forum?id=R2w60GCpGv¬eId=3raYg6KWPt",+ "license": "CC-BY-4.0"+}
reviews/openreview/r2w60gcpgv/notes/7cjqg7zl9c.json added
+++ b/reviews/openreview/r2w60gcpgv/notes/7cjqg7zl9c.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "7cjQg7Zl9C",+ "replyTo": null,+ "kind": "meta_review",+ "invitation": "Meta_Review",+ "signature": "Area Chair T92K",+ "content": {+ "metareview": "The paper presents a technically interesting post-training SVD compression method for physics foundation models, with broad evaluation across three model families and multiple PDE settings. I view the submission as **needing clarification**, with the following prioritized issues. \n\n1. **Reliability of the central empirical results.** As raised by Reviewers SeTW and XM4x, SAFE-SVD shows almost no degradation in several Poseidon settings while competing methods degrade by orders of magnitude. Please provide raw, unrounded losses in addition to relative percentages; clearly confirm calibration/test separation; explain the baseline adaptations and the differing final model sizes; and state whether the results are deterministic or sensitive to calibration-subset selection. This is important for excluding metric-scaling or evaluation artifacts.\n\n2. **Meaning of “physical fidelity.”** As noted by Reviewer XM4x, the method uses a Sobolev-augmented loss for sensitivity estimation and is then evaluated substantially through Sobolev error. Independent constraint-based evidence is mainly provided for incompressible Navier–Stokes. Please clarify which claims are supported across the other PDE families and narrow “physical fidelity” to derivative fidelity where conservation or constraint metrics are unavailable.\n\n3. **Theory–implementation alignment.** Please address Reviewer SeTW’s concern by distinguishing the quadratic activation-space surrogate used for the SVD derivation from the L1 Sobolev loss used to compute sensitivity. Also state the assumptions underlying the Fisher/Gauss–Newton approximation and omission of the first-order Taylor term.\n\n4. **Compression definition.** As requested by Reviewer pbxu, define precisely what ratios such as 0.2, 0.4, and 0.6 retain, explain why model sizes differ across methods at the same reported ratio, and distinguish parameter reduction from demonstrated memory or latency improvements.\n\nMinor presentation inconsistencies are not decision-critical, and extensive new experiments are not required during rebuttal; clarification using existing results or appropriately narrowed claims would suffice. If these issues are resolved convincingly, I would be inclined to support acceptance, subject to the final discussion."+ },+ "createdAt": "2026-07-21T07:45:04.004Z",+ "modifiedAt": "2026-11-18T15:18:56.448Z",+ "url": "https://openreview.net/forum?id=R2w60GCpGv¬eId=7cjQg7Zl9C",+ "license": "CC-BY-4.0"+}
reviews/openreview/r2w60gcpgv/notes/8zrqvsnykx.json added
+++ b/reviews/openreview/r2w60gcpgv/notes/8zrqvsnykx.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "8zrqVsNykX",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer pbxu",+ "content": {+ "summary": "The paper describes a compression techniques for neural networks specifically designed for physics applications. In particular, they introduce a layer compression based on sensitivity in the output space. They achieve higher compression ratios than the compared alternatives across various datasets, while maintaining accuracy.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "**Quality**\nThe paper proposes a method based on singular value decomposition. The technique is derived analytically and then applied on experiments on several datasets. The study also includes ablations on the various components.\nThe greedy global rank allocation is more empirical, but it is properly justified, and tested experimentally.\n\n**Clarity**\nThe paper reads well, the topic is appropriately introduced and motivated, images and tables describe the results. The main weakness that affects clarity is the use of physics terms such as \"physical fidelity\", \"physics-aware SVD\". In addition, \"physical fidelity\" may confuse the reader with a quantum physics background, where \"fidelity\" has a very specific meaning. \nA few minor concerns on clarity:\n- Defining the Sobolev norm as it is being used in the main text would be helpful to the general reader.\n- What is being compared in the tables is not immediately clear: what does the percentage represent (compression? error?). Specifically in Table 2 and 3: what is the number on the left (1, 0.6, 0,4, 0.2)? If it is the compression rate, it would be good to write, or add to the caption\n- Summarizing in the conclusions the average compression rate that was obtained for a given loss threshold can help the reader understand the impact of the work.\n- I believe the final sentence in the conclusions is too vague:\n> Also, there are other applications which do not require high precision, e.g. inverse design, and can benefit from model compression.\n\n**Significance**\nCompressing scientific models can reduce inference costs and enable broader applications by the community, lowering access barrier.\n\n**Originality**\nThe work takes inspiration for existing SVD compression techniques, and proposes a decomposition that takes into account the global loss rather than the layerwise change. If this is the main contribution, and the proposed technique is fully general and not only applicable on physics settings, it would be good to clarify it in the text: this is a general compression technique and it can be applied also to foundation models, but nothing in the derivation is necessarily \"physics aware\" or requires physics knowledge about the system, right?",+ "quality": 3,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "- What rank is used in the ablation with uniform rank allocation?\n- How to choose the size of the calibration set? How to choose the tradeoff between accuracy and compute?\n- Why the proposed SVD technique is physics-aware? (compared to the alternative baselines?\n- Could one remove references to \"physics aware loss\" and focus the narrative on the fact that a global loss is being used for compression? Or is there some assumption that requires physics knowledge about the inputs? The physics setting could just be part of the work's motivation?",+ "limitations": "yes",+ "rating": 5,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "no",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "I confirm my positive assessment."+ },+ "createdAt": "2026-06-26T10:43:43.021Z",+ "modifiedAt": "2026-11-18T13:35:44.254Z",+ "url": "https://openreview.net/forum?id=R2w60GCpGv¬eId=8zrqVsNykX",+ "license": "CC-BY-4.0"+}
reviews/openreview/r2w60gcpgv/notes/jprhuwzonj.json added
+++ b/reviews/openreview/r2w60gcpgv/notes/jprhuwzonj.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "jPRhuWzOnJ",+ "replyTo": "8zrqVsNykX",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "We thank the reviewers for their helpful and constructive feedback. Our responses are provided below.\n\n**Calirty 1: the use of physics terms such as \"physical fidelity\", \"physics-aware SVD\". In addition, \"physical fidelity\" may confuse the reader with a quantum physics background.**\n\nWe agree with the reviewer. ‘’Physical fidelity’’ in SAFE-SVD refers to the derivative structures. This is because SAFE-SVD is designed to work with different PDEs. Since physical fidelity has different meanings in different PDEs, e.g. divergence-free in NS-PwC and mass conservation in CE-RM, and the derivative structure is a common feature among PDEs, focusing on preserving this feature makes SAFE-SVD flexible. In this way, if the pretrained model can preserve fidelity and the fidelity can be described by partial derivatives, e.g. divergence-free, momentum conservation, SAFE-SVD also tends to preserve them. We will clarify.\n\n**Clarity 2: Defining the Sobolev norm as it is being used in the main text.**\n\nWe will move the definition of the Sobolev norm from the supplementary material to the main text for clarity.\n\n**Clarity 3: What do the percentages represent, and what do the numbers on the left of Tables 2 and 3 mean?**\n\nThe percentages report the relative increase of each metric over the uncompressed model:\n\n$$\n\\Delta L =\n\\frac{\\left|L_{\\mathrm{comp}}-L_{\\mathrm{origin}}\\right|}\n{\\left|L_{\\mathrm{origin}}\\right|+\\epsilon}\n\\times 100\\\\%.\n$$\n\nwhere $L_{comp}$ and $L_{origin}$ are some metric of the compressed and original model, such as the L1 norm of the prediction error. $\\epsilon$ is a small number to prevent divison by 0. Lower values are better. The leftmost values, \\{1, 0.6, 0.4, 0.2\\}, denote the target parameter retention ratio. Although all methods use retention ratio as a hyperparameter, some methods can’t precisely achieve the prescribed ratio, hence the differing sizes of the compressed models. Examples include Dobi-SVD and SVDLLM V2. We will clarify this definition in the captions of Tables 2 and 3.\n\n**Clarity 4: Summarizing in the conclusions the average compression rate that was obtained for a given loss threshold.**\n\nWe will add a concise summary of the achieved compression rates in the conclusion.\nFor example, for Poseidon, under a $2.5\\\\%$ CE-RM base-loss threshold, our method retains only $20\\\\%$ of the linear-layer parameters versus $60\\\\%$ for the strongest baseline SAES-SVD; under a $3\\\\%$ NS-PwC threshold, it retains $20\\\\%$ whereas all baselines require the full model.\n\n**Clarity 5: Final sentence in the conclusions is too vague.**\n\nWe will clarify this with a concrete example. Building ventilation design relies on aerodynamic simulations, where engineering decisions are often based on relative ventilation performance rather than exact flow predictions(Chen and Gorlé, 2022). Consequently, moderate approximation errors can often be tolerated, allowing compressed physics foundation models to serve as efficient surrogate models that substantially reduce computational cost.\n\n**Originality and Question 4: Can we remove references to \"physics aware loss\" and narrow it down to global loss.**\n\nSAFE-SVD does require physics knowledge about the inputs. The method is specifically designed for PFMs, whose inputs are functions, which is a key distinction from other foundation models. Accordingly, the entire design revolves around preserving compression-sensitive derivative structures, and the orders of these derivatives depend on the specific PDE family under consideration. Therefore, trimming SAFE-SVD down to only using a generic global loss would discard the central physics awareness of the method.\n\nThat said, we agree that, if only the base loss is used, components such as loss-aware sensitivity estimation and global rank allocation could potentially be adapted to other foundation models. We thank the reviewer for pointing out this possibility and will include it as an important direction for future work.\n\n**Question 1: What rank is used in the ablation with uniform rank allocation?**\n\nIn the uniform rank allocation ablation, the rank of each linear layer is computed as\n\n$$\nk = \\mathrm{int}\\left(\n\\frac{d_{\\mathrm{out}} \\times d_{\\mathrm{in}} \\times r}\n{d_{\\mathrm{out}} + d_{\\mathrm{in}}}\n\\right),\n$$\n\nwhere $d_{\\mathrm{out}}$ and $d_{\\mathrm{in}}$ are the output and input dimensions of the layer, respectively, and $r$ is the target parameter retention ratio. This yields approximately uniform parameter retention across layers.\n\n**Question 2: How to choose the size of the calibration set? How to choose the tradeoff between accuracy and compute?**\n\nWe provide new results on the trade-off between compression efficiency and performance on Poseidon. In practice, people can balance them based on their needs. \n\n### **Table: Accuracy–compute trade-off on Poseidon NS-PwC at retain ratio 0.2.**\n\n| Method | Calib. traj. | Rank selection (min) | Compression (min) | Total (min) | GPU alloc. peak (GB) | Base Loss | Div-Free | Vorticity |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| SAFE-SVD | 4 | 2.82 | 34.40 | 37.22 | 15.46 | 3.93% | 0.68% | 2.93% |\n| SAFE-SVD | 8 | 4.62 | 69.94 | 74.55 | 15.46 | 3.55% | 0.83% | 2.36% |\n| SAFE-SVD | 16 | 7.59 | 131.06 | 138.65 | 16.83 | 4.32% | 1.75% | 2.21% |\n| SAFE-SVD | 32 | 12.37 | 310.78 | 323.15 | 27.81 | 5.58% | 2.98% | 2.50% |\n| SAFE-SVD | 64 | 20.36 | 427.75 | 448.11 | 50.57 | 2.64% | 0.52% | 1.35% |\n\n**Question 3: Why the proposed SVD technique is physics-aware? (compared to the alternative baselines?**\n\nSAFE-SVD is physics-aware because it explicitly links intermediate-layer compression to the derivative structure of output function via a Sobolev loss. In contrast, ASVD, SVD-LLM V2, and SAES-SVD optimize only local reconstruction, without considering the global loss which includes the derivative structure. Although FWSVD considers the global loss, it doesn’t include derivative structures. Furthermore, unlike SAFE-SVD, FWSVD doesn’t capture the full Fisher information, only its diagnol elements, while the off-diagnol elements contain rich physics information."+ },+ "createdAt": "2026-07-28T10:55:24.454Z",+ "modifiedAt": "2026-11-18T17:11:31.631Z",+ "url": "https://openreview.net/forum?id=R2w60GCpGv¬eId=jPRhuWzOnJ",+ "license": "CC-BY-4.0"+}
reviews/openreview/r2w60gcpgv/notes/og227efu6g.json added
+++ b/reviews/openreview/r2w60gcpgv/notes/og227efu6g.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "oG227efU6g",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer SeTW",+ "content": {+ "summary": "The paper introduces SAFE-SVD which is an SVD based method for post-training model compression for physics foundation models. The main idea of the method is to make the model compression method physics-aware to preserve the physics properties that the model has learned. The method achieves this by defining a loss-aware layer sensitivity, combining the base loss with a Sobolev-space loss and using Fisher Information Matrix. The method also includes modeling cross-layer error propagation and a rank-allocation algorithm to keep the learned physics in the model. SAFE-SVD has been evaluated on Poseidon, VICON and MPP pre-trained models on different PDEs such as Navier-Stokes, Euler, wave, diffusion-reaction and is also compared with some of the SVD-baselines such as FWSVD, ASVD, Dobi-SVD and SAES-SVD. The results show that their method outperforms the baselines in almost all the PDEs and pre-trained models.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "### Strengths\n\n1. Compression of physics foundation models is not a very explored domain and the observation that conventional SVD-based compression methods do not necessarily preserve the learned physics properties is a good motivation.\n2. Mathematical derivations connecting loss-aware objective to low-rank problems is well explained and easy to follow.\n3. The paper evaluates on 3 models, i.e., Poseidon, VICON and MPP and on different PDE families. The results on compression ratios with base loss and Sobolev loss and some PDE-specific metrics are promising. The rollout comparisons in the figures of the main paper are an interesting result and help understand how they keep the physical properties and not just metric values.\n4. The method outperforms in the case of PDEs such as Navier-Stokes, Euler and wave equations compared to almost all the baselines and has low degradation even under high compressions.\n\n\n### Weaknesses\n\n1. On Poseidon in Table 2 and 4, the method reports almost 0% degradation across base and Sobolev loss and some other metrics while the other baselines degrade by 100s and 1000s of percentages. I am not sure if there is any metric saturation anywhere or some data leakage causing this. Can the authors explain this? Is there a way to compare the true loss values or to find the difference between predicted fields? Also there is no mention of if the experiments are averaged across multiple runs or if they are from a single run.\n2. Section 4.1 and Table 1 have some differences in the results reported. For e.g., the table report 19.72% but the paragraph reports 19.70% for the same configuration. Please fix this inconsistency.\n3. The paper uses L2 norm for the loss and objective functions in Section 3.1 but the paper discusses results only on L1 norm in the experiments. The paper should clarify why L1 outperforms L2 and could rederive derivations for L1.",+ "quality": 4,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "1. Can the authors report experiments for multiple runs and also provide some error bars for the results?\n2. Is it possible to show results for L2 norm as well to compare with the L1 norm results in the experiments?",+ "limitations": "Yes",+ "rating": 4,+ "confidence": 2,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "No",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "The authors have responded to most of my queries and I feel I can raise my score to 4 from 3. The remaining issues as of right now are with the reported values and the calibration details presented on VICON and MPP."+ },+ "createdAt": "2026-06-24T01:37:02.607Z",+ "modifiedAt": "2026-11-18T13:35:46.402Z",+ "url": "https://openreview.net/forum?id=R2w60GCpGv¬eId=oG227efU6g",+ "license": "CC-BY-4.0"+}
reviews/openreview/r2w60gcpgv/notes/r0x0kdf0n4.json added
+++ b/reviews/openreview/r2w60gcpgv/notes/r0x0kdf0n4.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "R0X0kDF0n4",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer XM4x",+ "content": {+ "summary": "This paper introduces SAFE-SVD, a post-training, physics-aware SVD compression method for physics foundation models (PFMs) that estimates layer sensitivity from a Sobolev-augmented loss, compresses layers sequentially to handle cross-layer error propagation, and allocates ranks globally with a greedy benefit–cost score. The authors report that it substantially outperforms existing SVD baselines, retaining both predictive accuracy and physical fidelity across several PFMs and PDE families.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "**Strengths**\n\n- The problem is timely and clearly motivated. The compression of PFMs is still under-explored, and the paper makes a convincing case that derivative-level and constraint-related physical fidelity matters beyond pointwise prediction accuracy.\n- The paper is well-structured and easy to follow.\n- The empirical evaluation is broad and generally strong, comparing against several SVD-based baselines across multiple PFMs, PDE families, compression ratios, and physics-aware metrics.\n\n**Weaknesses**\n\n- W1. None of the results report error bars, confidence intervals, or variation across calibration subsets, which makes it difficult to judge the significance of close comparisons. Since SAFE-SVD relies on calibration data to estimate activation statistics and sensitivity matrices, reporting variability across calibration subsets would strengthen the empirical claims.\n\n- W2. The central claim is preservation of physical fidelity, but much of the supporting evidence rests on the Sobolev loss, which is closely aligned with the Sobolev-augmented loss used to construct the sensitivity-aware objective. This shows that the method preserves the derivative-matching structure it is designed to preserve, but it provides limited independent evidence of physical correctness. The more direct constraint-based check, the divergence-free error, is reported only for incompressible Navier-Stokes. The authors should report constraint- or conservation-based metrics for other PDE families, such as energy, momentum, or mass conservation where applicable, to provide evidence of physical fidelity that is independent of the Sobolev metric.",+ "quality": 3,+ "clarity": 3,+ "significance": 4,+ "originality": 3,+ "questions": "See above.",+ "limitations": "Yes",+ "rating": 5,+ "confidence": 3,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "N/A",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "Both weaknesses are resolved and I keep my rating of 5 (Accept)."+ },+ "createdAt": "2026-06-22T16:42:06.974Z",+ "modifiedAt": "2026-11-18T13:35:47.328Z",+ "url": "https://openreview.net/forum?id=R2w60GCpGv¬eId=R0X0kDF0n4",+ "license": "CC-BY-4.0"+}
reviews/openreview/r2w60gcpgv/notes/rsod8rhdes.json added
+++ b/reviews/openreview/r2w60gcpgv/notes/rsod8rhdes.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Rsod8RhDES",+ "replyTo": "R0X0kDF0n4",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "We thank the reviewers for their helpful and constructive feedback. Our responses are provided below.\n\n**W1: report variability across calibration subsets.** \n\nWe provide new experiments on 5 calibration subsets which are randomly sampled from the training data. The results indicate that our method is not sensitive to calibration subset. The overall performance remains consistent with our experiments in main text. We report mean ± standard deviation across compressed models.\n\n### **Table: Poseidon**\n\n| Ratio | Method | Size | NS-PwC: Base Loss ↓ | NS-PwC: Sobolev ↓ | NS-PwC: Div-Free ↓ | NS-PwC: Vorticity ↓ | CE-RM: Base Loss ↓ | CE-RM: Sobolev ↓ | Wave-Gauss: Base Loss ↓ | Wave-Gauss: Sobolev ↓ |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 1.0 | Origin | 628.6M | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% |\n| 0.8 | Ours | 503.0M | 0.02% ± 0.00% | 0.00% ± 0.00% | 0.00% ± 0.00% | 0.00% ± 0.00% | 0.00% ± 0.00% | 0.00% ± 0.00% | 0.01% ± 0.01% | 0.00% ± 0.00% |\n| 0.6 | Ours | 377.5M | 0.00% ± 0.01% | 0.01% ± 0.00% | 0.00% ± 0.00% | 0.01% ± 0.00% | 0.00% ± 0.00% | 0.00% ± 0.00% | 0.03% ± 0.03% | 0.07% ± 0.06% |\n| 0.4 | Ours | 251.9M | 0.22% ± 0.01% | 0.09% ± 0.00% | 0.02% ± 0.00% | 0.12% ± 0.01% | 0.01% ± 0.00% | 0.05% ± 0.00% | 0.04% ± 0.02% | 0.48% ± 0.28% |\n| 0.2 | Ours | 126.3M | 3.93% ± 1.43% | 4.13% ± 2.45% | 2.17% ± 0.54% | 1.77% ± 0.47% | 0.20% ± 0.02% | 1.32% ± 0.46% | 1.02% ± 0.30% | 152.1% ± 32.21% |\n\n### **Table: VICON**\n\n| Ratio | Method | Size | NS-2D: Base Loss ↓ | NS-2D: Sobolev ↓ | NS-2D: Div-Free ↓ | NS-2D: Vorticity ↓ | Comp-2D: Base Loss ↓ | Comp-2D: Sobolev ↓ | Euler-2D: Base Loss ↓ | Euler-2D: Sobolev ↓ |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 1.0 | Origin | 87.8M | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% |\n| 0.8 | Ours | 70.3M | 2.49% ± 1.58% | 0.64% ± 0.46% | 0.16% ± 0.09% | 0.61% ± 0.34% | 2.35% ± 1.38% | 0.94% ± 0.51% | 3.39% ± 2.61% | 20.13% ± 12.71% |\n| 0.6 | Ours | 52.8M | 2.20% ± 1.71% | 0.40% ± 0.49% | 0.34% ± 0.09% | 1.30% ± 0.45% | 17.09% ± 3.57% | 7.40% ± 0.66% | 7.10% ± 4.20% | 14.17% ± 14.16% |\n| 0.4 | Ours | 35.3M | 20.57% ± 1.87% | 3.20% ± 0.46% | 0.98% ± 0.13% | 8.51% ± 0.59% | 68.73% ± 2.40% | 24.44% ± 1.17% | 28.48% ± 4.61% | 17.98% ± 12.82% |\n| 0.2 | Ours | 17.8M | 236.1% ± 4.17% | 20.21% ± 0.42% | 7.31% ± 0.17% | 65.38% ± 0.90% | 973.3% ± 37.64% | 101.9% ± 3.20% | 261.4% ± 10.65% | 13.82% ± 5.34% |\n\n### **Table: MPP**\n\n| Ratio | Method | Size | IncompNS: Base Loss ↓ | IncompNS: Sobolev ↓ | IncompNS: Div-Free ↓ | IncompNS: Vorticity ↓ | CompNS: Base Loss ↓ | CompNS: Sobolev ↓ | DiffRe-2D: Base Loss ↓ | DiffRe-2D: Sobolev ↓ | SWE: Base Loss ↓ | SWE: Sobolev ↓ |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 1.0 | Origin | 407.1M | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% | 0.00% |\n| 0.8 | Ours | 366.8M | 15.59% ± 1.25% | 1.52% ± 0.16% | 0.06% ± 0.03% | 2.69% ± 0.36% | 0.19% ± 0.11% | 0.07% ± 0.02% | 3.53% ± 0.83% | 0.87% ± 0.07% | 16.15% ± 2.50% | 2.31% ± 0.30% |\n| 0.6 | Ours | 326.5M | 90.40% ± 3.13% | 8.87% ± 0.68% | 0.22% ± 0.06% | 16.63% ± 0.87% | 1.65% ± 0.21% | 0.51% ± 0.07% | 14.96% ± 2.92% | 3.20% ± 0.18% | 67.86% ± 6.03% | 9.45% ± 0.75% |\n| 0.4 | Ours | 286.3M | 407.0% ± 9.32% | 36.15% ± 2.96% | 0.64% ± 0.16% | 64.71% ± 3.52% | 12.60% ± 0.94% | 2.74% ± 0.26% | 63.79% ± 8.49% | 11.25% ± 0.53% | 264.4% ± 21.07% | 35.33% ± 1.97% |\n| 0.2 | Ours | 246.0M | 1918% ± 102.2% | 131.4% ± 8.86% | 2.08% ± 0.26% | 197.5% ± 9.06% | 93.72% ± 4.97% | 12.38% ± 0.22% | 318.0% ± 31.47% | 42.95% ± 2.19% | 1225% ± 88.25% | 131.5% ± 4.03% |\n\n**W2: Report constraint- or conservation-based metrics for other PDE families.**\n\nWe additionally report PDE-specific physical-consistency metrics, since different PDEs describe different physical scenarios. Specifically, for CE-RM, we evaluate mass, momentum, and total-energy conservation metrics. For Wave-Gauss, the wave-speed field $c(\\mathbf{x})$ is time-invariant, as specified in Poseidon. We therefore report the following constraint-based metric\n\n$$\n\\\\mathcal{E}\\_{c}=\\\\frac{1}{|\\\\Omega|}\\\\sum\\_{\\\\mathbf{x}\\\\in\\\\Omega}\\\\left|\\\\hat{c}\\_{t}(\\\\mathbf{x})-\\\\hat{c}\\_{t-\\\\Delta t}(\\\\mathbf{x})\\\\right|.\n$$\n\n### **Table: Poseidon**\n\n| Ratio | Method | Size | CE-RM: Mass ↓ | CE-RM: Momentum ↓ | CE-RM: Energy ↓ | Wave-Gauss: Speed ↓ |\n| --- | --- | --- | --- | --- | --- | --- |\n| 1.0 | Origin | 628.6M | 0.00% | 0.00% | 0.00% | 0.00% |\n| 0.6 | ASVD | 377.1M | 70.62% | 61.21% | 67.38% | 2093% |\n| 0.6 | FWSVD | 377.1M | 66.91% | 59.12% | 64.05% | 602.6% |\n| 0.6 | SVD-LLM V2 | 420.0M | 72.16% | 55.35% | 69.97% | 1337% |\n| 0.6 | Dobi-SVD | 378.7M | 74.70% | 16.49% | 73.50% | 1538% |\n| 0.6 | SAES-SVD | 377.1M | 45.07% | 34.93% | 44.02% | 1713% |\n| **0.6** | **Ours** | **377.5M** | **0.00%** | **0.00%** | **0.00%** | **0.00%** |\n| 0.4 | ASVD | 251.5M | 71.68% | 55.09% | 68.56% | 3813% |\n| 0.4 | FWSVD | 251.5M | 59.17% | 35.82% | 53.31% | 967.2% |\n| 0.4 | SVD-LLM V2 | 342.5M | 45.64% | 14.00% | 41.66% | 3692% |\n| 0.4 | Dobi-SVD | 252.6M | 70.09% | 24.94% | 65.65% | 1886% |\n| 0.4 | SAES-SVD | 251.5M | 49.01% | 34.17% | 46.93% | 1947% |\n| **0.4** | **Ours** | **251.9M** | **0.00%** | **0.01%** | **0.01%** | **0.26%** |\n| 0.2 | ASVD | 125.6M | 58.53% | 57.60% | 53.09% | 3347% |\n| 0.2 | FWSVD | 125.9M | 48.62% | 93.66% | 43.75% | 2457% |\n| 0.2 | SVD-LLM V2 | 313.5M | 35.33% | 35.92% | 34.41% | 4677% |\n| 0.2 | Dobi-SVD | 127.0M | 69.53% | 36.65% | 62.92% | 3257% |\n| 0.2 | SAES-SVD | 125.9M | 55.31% | 33.72% | 51.94% | 2159% |\n| **0.2** | **Ours** | **126.3M** | **0.72%** | **0.65%** | **0.86%** | **96.47%** |"+ },+ "createdAt": "2026-07-28T11:01:56.287Z",+ "modifiedAt": "2026-11-18T17:11:31.521Z",+ "url": "https://openreview.net/forum?id=R2w60GCpGv¬eId=Rsod8RhDES",+ "license": "CC-BY-4.0"+}
reviews/openreview/r2w60gcpgv/submission.json added
+++ b/reviews/openreview/r2w60gcpgv/submission.json@@ -0,0 +1,12 @@+{+ "schema": "submission/1",+ "id": "R2w60GCpGv",+ "venue": {+ "id": "NeurIPS.cc/2026/Conference",+ "name": "NeurIPS 2026",+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"+ },+ "number": 4336,+ "url": "https://openreview.net/forum?id=R2w60GCpGv",+ "license": "CC-BY-4.0"+}
versions/v_s5j8jqyj.json added
+++ b/versions/v_s5j8jqyj.json@@ -0,0 +1,22 @@+{+ "date": "2026-04-23",+ "kind": "submitted",+ "label": "NeurIPS 2026",+ "submissions": [+ {+ "venue": "NeurIPS 2026",+ "status": "accepted",+ "decision": "Accept (poster)",+ "number": 4336,+ "url": "https://openreview.net/forum?id=R2w60GCpGv",+ "reviews": "openreview/r2w60gcpgv",+ "evidence": [+ "https://openreview.net/forum?id=R2w60GCpGv"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=R2w60GCpGv",+ "evidence": [+ "https://openreview.net/forum?id=R2w60GCpGv"+ ]+}