potentialpaper

NeuroNTP - A Generalizable Multimodal Foundation Model for Epilepsy

Update NeurIPS 2026 submission seM8LkgKy6: 9 notes

@openreview[bot] · 2026-11-24 15:56 UTC · ca2249720785 ·

Evidence

reviews/openreview/sem8lkgky6/notes/06r1hkscaj.json added

+++ b/reviews/openreview/sem8lkgky6/notes/06r1hkscaj.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "06R1hKSCaj",
+ "replyTo": "aeq3V9ZW6V",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the reviewer for the continued engagement and for the constructive tone throughout. We address each point below.\n\n**Q1a Data scaling.**\nTo evaluate pretraining data scaling, we kept the architecture, training pipeline, epochs, and hyperparameters fixed, varying only the pretraining data (25%, 50%, 75%, 100%). Subsets were patient-level, nested, and stratified by recording duration. Representations were evaluated by identical linear probing on a held-out patient set. Preliminary results:\n\n| Data Scale | NTP Loss | AUPRC | AUROC |\n|:----------|------:|-------:|---------:|\n| 100% | **0.0356** | **41.65** | **79.34** |\n| 75% | 0.0735 | 41.09 | 78.28 |\n| 50% | 0.0796 | 38.63 | 77.17 |\n| 25% | 0.1368 | 31.70 | 71.83 |\n\n**Q1b Parameter scaling.** Thank you; we will include the parameter-scaling analysis in the final version.\n\n**Q2 Channel-specific adaptation vs. zero-shot.** We will explicitly distinguish adapted and zero-shot tokenizer parameters in the text and table captions, preventing any conflation of the two settings. This will be folded into the same input-visibility labeling we are adding for the deployment settings.\n\n**Q3 Spatial encoding vs. Seegnificant / PopT / BaRISTA.** We accept this correction and will revise the comparison. Prior work already supports unseen-electrode adaptation; our intended distinction is mechanistic rather than capability-based. NeuroNTP represents electrodes by continuous 3D-coordinate projections and initializes new electrodes from the nearest spatial neighbor (Appendix J.2), rather than relying solely on learned per-label embeddings. We will revise lines ~662–667 accordingly, cite BaRISTA, PopT, and Seegnificant, and state that geometry-based unseen-electrode adaptation is a shared direction rather than a unique contribution.\n\n**Limitation / Transformer complexity.** We will scope these claims precisely to streaming inference over long continuous recordings and update the wording accordingly. Concretely: (i) the contribution bullet (line ~40) and the positioning text (lines ~671–673) will be qualified so that the linear-complexity/stateful-inference advantage is stated for the streaming long-context regime rather than in general; (ii) the \"standard Transformers struggle … due to quadratic scaling\" claim (lines ~660–661) will be reworded to refer specifically to memory/latency growth under streaming over long histories; and (iii) each of these will point to Appendix I.4 (Figure 12), where Transformer variants exhaust memory beyond ~20–25k tokens while xLSTM holds constant latency and memory.\n\n**§5.2.3 (lines 280–295): auxiliary-task rewrite.** We will rewrite this section to report and interpret results per task, rather than describe the tasks alone. The planned structure:\n\n*Clinical Marker Inference* → results from Table 2 (group-level marker detection) with the confusion matrix in Appendix G. Interpretation: the model reconstructs clinically meaningful annotation semantics from biosignals, strongest for EEG-phenomenon markers (F1 81.6%), which have direct electrographic correlates, and weaker for behavioural/other markers (F1 46.7% / 23.9%), which depend on context not present in the biosignal stream; evidence that the learned representations align physiological patterns with clinical vocabulary where such a correlate exists.\n\n*Time-to-Seizure (TTS) regression* → the linear-probing evaluation showing that pre-seizure latent trajectories carry linearly separable proximity information, complemented by the ablation in Table 13, where removing TTS is the single largest degradation - establishing TTS as the dominant driver of representation quality.\n\n*Structural tasks (TPS, token-type, segment-type)* → the corresponding Table 13 ablation rows for each objective's marginal contribution, and the frozen segment-type linear-probing results with biosignal-only input (Table 3) as a direct read of ictal/non-ictal separability across KUK, CHB-MIT, and Siena, extended by using two pretraining configurations (biosignal-only and multimodal).\n\nThe section will close by tying these together: the auxiliary evaluations jointly show the representations encode clinical-annotation semantics, temporal proximity to seizures, and ictal/non-ictal structure, which is the concrete evidence behind our claim that proximity-shaped multitask supervision yields semantically and temporally rich representations.\n\nWe are grateful for the specificity of these suggestions, which have made the intended revisions much clearer."
+ },
+ "createdAt": "2026-08-04T09:52:06.770Z",
+ "modifiedAt": "2026-11-19T16:45:58.038Z",
+ "url": "https://openreview.net/forum?id=seM8LkgKy6&noteId=06R1hKSCaj",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/sem8lkgky6/notes/6n1d7difz0.json added

+++ b/reviews/openreview/sem8lkgky6/notes/6n1d7difz0.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "6n1D7diFz0",
+ "replyTo": "gbkFoTjS78",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the reviewer for the thoughtful replies and for the constructive framing, which we fully adopt.\n1. Novelty\n- **Reframing the core contribution:** We will present causal streaming NTP combined with seizure-proximity supervision (TTS/TPS) as the central methodological component early in the text, rather than leaving it to be inferred from the ablations.\n- **Clarifying supervision requirements:** We will explicitly state that TTS/TPS require seizure-timing annotations during pretraining. Crucially, we will emphasize that downstream inference remains strictly biosignal-only. We will also expand Appendix H (TUSZ reproduction) to detail how these annotations are derived, proving this data requirement is readily satisfiable using standard public datasets outside KUK.\n- **Narrowing the novelty claim**: we accept that multimodal physiological pretraining (e.g., SleepFM) and the tokenize→pretrain→supervise scheme are established. We will (i) credit this prior work, (ii) drop the claim of a new general multimodal pretraining paradigm, and (iii) state our contribution specifically as the integration of causal streaming, temporally-aligned clinical text, and seizure-proximity supervision for multimodal epilepsy monitoring.\n\n2. Thank you, this matches what we will do. We will promote the montage-geometry method to the main text consolidated with the clarifications related to Q3 of reviewer s5Th, and add a leave-montage-out evaluation that isolates its empirical impact.\n\n3. We agree this is a fair point. The reviewer is right that masked reconstruction and contrastive objectives have been used effectively for diagnosis and prediction, and that masked reconstruction can be adapted to a causal backbone (e.g., prefix-conditioned reconstruction of masked channels or modalities). A controlled, matched-compute comparison across objectives would indeed sharpen the specific benefit of NTP. Because such a comparison requires pretraining separate models under each objective at matched compute and architecture - being non-trivial within the rebuttal window - we scope it as future work, and will extend the framework to support alternative objectives (including causal prefix-masked reconstruction) so these comparisons can be run cleanly. In the revision we will correspondingly motivate NTP by its fit to the deployment setting - causal streaming inference, stateful updates over long recordings.\n\n4. Thank you. We will present these results - the public-dataset reproduction, the modality ablations, and the data-scaling study - with enhanced clarity and context in the revised manuscript, so that the evidence bearing on the source of the performance gains is easy to locate and interpret.\n\n5. We thank the reviewer for confirming our rationale. As requested, we will incorporate this architectural justification directly into the main text. \n\n6. Applicability of existing Multimodal Baselines\nGiven the rapid development and the wide field, we thank the reviewer for pointing out these works. We will discuss their applicability to our seizure detection and prediction tasks. If possible, we will also run linear-probing on readily available foundation models to assess and compare their generalization to these tasks.\nWe extend our Table 6 (Recent Brain Signal Foundation Models) to include the following:\n\n| Model | Backbone (Complexity) | Objective | Modality | Montage Agnostic | Pretraining Data | Weights |\n|---|---|---|---|---|---|---|\n| **SleepFM** | 1D CNN ($O(N)$) | Contrastive Learning | EEG+EOG+EMG+ECG+Resp. | ✗ | Private PSG (≈100k h) | ✓ |\n| **BrainOmni** | Criss-Cross Trans. ($O(N \\sqrt{N C})$) | Masked Code Pred. | EEG+MEG | ✓ | Public EMEG (≈2.6k h) | ✓ |\n| **Biosignal MAE** | Transformer ($O(N^2)$) | MultiMAE | EEG+ECG+EOG+EMG | ✗ | PhysioNet18 (≈15k h) | ✗ |\n| **PhysioOmni** | VQ-VAE Trans. ($O(N^2)$) | Recon. + Masked Code Pred. | EEG+ECG+EOG+EMG | ✗ | Public + Private (≈25k h) | ✓ \n| **NeuroNTP** | xLSTM ($O(N)$) | Causal NTP + Aux. | EEG+ECG+SpO$_2$+text | ✓ | Private KUK (>150k h) | ✓ |"
+ },
+ "createdAt": "2026-08-04T09:36:40.769Z",
+ "modifiedAt": "2026-11-19T16:45:58.257Z",
+ "url": "https://openreview.net/forum?id=seM8LkgKy6&noteId=6n1D7diFz0",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/sem8lkgky6/notes/aeq3v9zw6v.json added

+++ b/reviews/openreview/sem8lkgky6/notes/aeq3v9zw6v.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "aeq3V9ZW6V",
+ "replyTo": "oe0LH91usp",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer s5Th",
+ "content": {
+ "comment": "I would like to thank the authors for taking the time to respond to my questions and for providing detailed clarifications. I really appreciate the effort that went into addressing my concerns.\n\n> We note this does not uniquely identify the author group — the cohort spans an 11-year acquisition period across a broad internal and externaal research network — so we do not believe it compromised the double-blind assessment.\n\nThank you for the clarification. While I agree that this does not uniquely identify the author group, I do think it substantially narrows down the set of possible groups that could have produced this work. For researchers who are closely familiar with this area, I believe this information could meaningfully compromise the double-blind review process. I would encourage the authors to be a bit more cautious with similar details in future submissions.\n\n> Q1a — Data scaling\n\nIf you are able to obtain these results before the rebuttal deadline, I would be very interested to see them. Please do let me know if they become available.\n\n> Q1b — Parameter scaling\n\nThank you for providing this additional analysis. I think these results strengthen the paper's scalability claims and would make a valuable addition to the manuscript. I encourage you to include them in the final version.\n\n> Q2 — Channel-specific adaptation vs. zero-shot\n\nThank you for the clarification. I think it would be very helpful to make this distinction explicit in the manuscript. In particular, please clearly indicate whenever parameters are fine-tuned so that readers can accurately interpret the reported results and avoid confusing fine-tuned and zero-shot settings.\n\n> Q3 — Spatial encoding vs. seegnificant / PopT / BaRISTA\n\n> rather than learned positional embeddings over a fixed electrode set, we use a continuous 3D-coordinate projection that is (i) independent of any fixed montage vocabulary and (ii) usable to initialize adaptation to unseen electrodes\n\nI believe this particular claim may not be entirely accurate. My understanding is that BaRISTA also supports adaptation to previously unseen electrodes, and I believe similar capabilities exist in Seegnificant and PopT as well. More generally, none of these methods rely on a truly \"fixed electrode set\", as such an assumption would not be practical given the distributed and highly variable nature of invasive EEG recordings. I would encourage the authors to either refine this comparison or more clearly explain the specific distinction they are trying to make.\n\n> Limitation — Transformer complexity\n\n> Our claim is specifically about streaming inference over very long continuous recordings, where these still scale unfavourably — Appendix I.4 measures Transformer memory exhausting beyond ~20–25k tokens while xLSTM holds constant latency and memory\n\nThank you for clarifying the scope of this claim. Please make sure the manuscript is updated to reflect this more precise wording so that the claims are presented accurately. If time allows, please explain which claims (can reference by line in text) you plan to revise and how.\n\n> §5.2.3 (lines 280–295)\n\n> ** We will rewrite it to report results for the auxiliary/marker-inference tasks (drawing on Table 2 and Appendix G) and state what they show about representation quality.\n\nThank you for the clarification. If time permits, I would appreciate a bit more detail on how you plan to revise this section. In particular, it would be helpful to explicitly connect each experiment to its corresponding result and explain how those results can be interpreted. While I appreciate your commitment to improving the presentation, having this additional context would provide useful information as I consider whether to update my score.\n\nOverall, I appreciate the thoughtful and detailed rebuttal. The authors addressed many of my questions, and I found the additional analyses and clarifications helpful. I believe that incorporating the promised revisions into the manuscript will make the paper significantly stronger and easier for readers to follow. I wish the authors the best of luck with the paper and look forward to seeing the final version."
+ },
+ "createdAt": "2026-07-31T04:46:11.994Z",
+ "modifiedAt": "2026-11-19T16:45:58.353Z",
+ "url": "https://openreview.net/forum?id=seM8LkgKy6&noteId=aeq3V9ZW6V",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/sem8lkgky6/notes/bp5jy5jvwk.json modified

+++ b/reviews/openreview/sem8lkgky6/notes/bp5jy5jvwk.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair nyYE",
"content": {
- "metareview": "**Summary:** \nThis paper introduces NeuroNTP, an xLSTM-based multimodal foundation model that unifies EEG, ECG, SpO₂, clinical text, temporal context, and metadata through geometry-aware tokenization and causal next-token pretraining with seizure-specific auxiliary objectives. The model is pretrained on more than 150,000 hours of private clinical recordings and evaluated on seizure detection, prediction, and clinical-marker inference using the KUK cohort and the public CHB-MIT and Siena Scalp EEG benchmarks. Although the results demonstrate strong cross-dataset performance and promising efficiency for continuous monitoring, the reviewers raised substantial concerns regarding technical novelty, deployment-faithful evaluation, attribution of performance gains, and reproducibility. \n\n**Strengths:** \nReviewers idBm, YwCK, and s5Th consistently recognize the importance of the clinical problem, the exceptional scale and multimodal richness of the pretraining dataset, and the practical value of integrating heterogeneous physiological signals and clinical context within a unified framework. They also acknowledge the strong empirical performance across multiple epilepsy-related tasks and datasets, the efficient stateful architecture, the broad baseline coverage, and the planned release of code and pretrained weights. \n\n**Weaknesses:** \nReviewers idBm and s5Th question whether the methodological contribution is sufficiently novel, noting that next-token prediction, multimodal token concatenation, xLSTM, and spatial electrode encodings largely build upon existing techniques and that comparisons with relevant multimodal or sub-quadratic foundation models remain incomplete. Reviewers idBm and s5Th also find the source of the reported gains insufficiently disentangled, requesting controlled scaling, backbone, objective, modality, and pretraining-data ablations to separate the effects of dataset scale and quality from those of the proposed design. Reviewer YwCK raises a central deployment concern that clinical markers, post-hoc notes, seizure delimiters, or ground-truth time-past-seizure information may provide unavailable or potentially leakage-prone signals at inference, while the parameterization of the multi-quantile next-token objective is also unclear. Reviewers YwCK and s5Th further note that the broad SOTA and zero-shot montage-generalization claims require more precise qualification and validation, while reliance on a non-public private dataset, potentially identifying institutional information, and incomplete descriptions of some auxiliary-task results limit reproducibility and confidence in the conclusions. \n\n**Response Direction:** \nThe acceptance likelihood could increase substantially if the response provides a strict biosignal-only, causally valid evaluation without seizure-derived annotations or ground-truth TPS, controlled experiments disentangling data scale, architecture, modalities, and objectives, clearer validation and novelty positioning for montage generalization, and precise corrections or clarifications regarding the quantile loss, SOTA claims, baseline comparability, and reproducibility.\n\n---\n\nFinal Assessment:\n\nThe authors provided substantive clarifications in response to several of the technical concerns raised during review, including the biosignal-only evaluation setting, the scope of the SOTA claims, and the role of seizure-derived annotations. Nevertheless, some important concerns remain only partially resolved, with several proposed remedies deferred to revisions rather than supported by new, independently verifiable evidence. I recommend weak accept."
+ "metareview": "**Summary:** \nThis paper introduces NeuroNTP, an xLSTM-based multimodal foundation model that unifies EEG, ECG, SpO₂, clinical text, temporal context, and metadata through geometry-aware tokenization and causal next-token pretraining with seizure-specific auxiliary objectives. The model is pretrained on more than 150,000 hours of private clinical recordings and evaluated on seizure detection, prediction, and clinical-marker inference using the KUK cohort and the public CHB-MIT and Siena Scalp EEG benchmarks. Although the results demonstrate strong cross-dataset performance and promising efficiency for continuous monitoring, the reviewers raised substantial concerns regarding technical novelty, deployment-faithful evaluation, attribution of performance gains, and reproducibility. \n\n**Strengths:** \nReviewers idBm, YwCK, and s5Th consistently recognize the importance of the clinical problem, the exceptional scale and multimodal richness of the pretraining dataset, and the practical value of integrating heterogeneous physiological signals and clinical context within a unified framework. They also acknowledge the strong empirical performance across multiple epilepsy-related tasks and datasets, the efficient stateful architecture, the broad baseline coverage, and the planned release of code and pretrained weights. \n\n**Weaknesses:** \nReviewers idBm and s5Th question whether the methodological contribution is sufficiently novel, noting that next-token prediction, multimodal token concatenation, xLSTM, and spatial electrode encodings largely build upon existing techniques and that comparisons with relevant multimodal or sub-quadratic foundation models remain incomplete. Reviewers idBm and s5Th also find the source of the reported gains insufficiently disentangled, requesting controlled scaling, backbone, objective, modality, and pretraining-data ablations to separate the effects of dataset scale and quality from those of the proposed design. Reviewer YwCK raises a central deployment concern that clinical markers, post-hoc notes, seizure delimiters, or ground-truth time-past-seizure information may provide unavailable or potentially leakage-prone signals at inference, while the parameterization of the multi-quantile next-token objective is also unclear. Reviewers YwCK and s5Th further note that the broad SOTA and zero-shot montage-generalization claims require more precise qualification and validation, while reliance on a non-public private dataset, potentially identifying institutional information, and incomplete descriptions of some auxiliary-task results limit reproducibility and confidence in the conclusions. \n\n**Response Direction:** \nThe acceptance likelihood could increase substantially if the response provides a strict biosignal-only, causally valid evaluation without seizure-derived annotations or ground-truth TPS, controlled experiments disentangling data scale, architecture, modalities, and objectives, clearer validation and novelty positioning for montage generalization, and precise corrections or clarifications regarding the quantile loss, SOTA claims, baseline comparability, and reproducibility.\n\n---\n\nFinal Assessment:\n\nThe authors provided substantive clarifications in response to several of the technical concerns raised during review, including the biosignal-only evaluation setting, the scope of the SOTA claims, and the role of seizure-derived annotations. Nevertheless, some important concerns remain only partially resolved, with several proposed remedies deferred to revisions rather than supported by new, independently verifiable evidence. I recommend weak accept.",
+ "final_justification": "Please see the updated meta-review above for the final justification.\n\n---\n\nNote from PC: The appeal of hallucinated reference determination has been reviewed. The decision now reflects the outcome of the appeals process as well as the content of the reviews, scores, and meta-review."
},
"createdAt": "2026-07-22T18:27:52.851Z",
- "modifiedAt": "2026-11-18T15:18:57.539Z",
+ "modifiedAt": "2026-11-19T04:59:23.939Z",
"url": "https://openreview.net/forum?id=seM8LkgKy6&noteId=BP5JY5jVwK",
"license": "CC-BY-4.0"
}

reviews/openreview/sem8lkgky6/notes/f5asxenwyy.json added

+++ b/reviews/openreview/sem8lkgky6/notes/f5asxenwyy.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "f5asxENwYY",
+ "replyTo": "J4mZrNVqCM",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer YwCK",
+ "content": {
+ "comment": "Thank you for the detailed and transparent response. The rebuttal substantially clarifies my main concern regarding whether the reported gains depend on information unavailable at deployment.\n\nQ1 — Which markers are visible during KUK inference?\n\nYour clarification that the submitted “with clinical text” result excluded explicit seizure-event and delimiter markers such as Anfall, EEG-Beginn, and EEG-Ende addresses my main concern here. The proposed marker-group decomposition is useful, particularly because it separates the deployment-valid configuration from the retrospective annotation-assisted setting. Please include this distinction clearly in the revised paper and specify the marker groups sufficiently for readers to understand what information is available in each condition. I consider Q1 largely resolved.\n\nQ2 — Are notes available before prediction time?\n\nThank you for stating clearly that you cannot guarantee that every note was available in its final form before prediction time. This answers my question. Therefore, I believe the appropriate interpretation is that note-assisted results are retrospective or annotation-assisted, rather than strictly prospective. Since the main biosignal-only results do not seem to use these notes, I do not view this as affecting the core external-transfer claims. I consider Q2 resolved, subject to the promised clarification in the manuscript.\n\nQ3 — How is TPS computed at test time?\n\nThe response makes clear that the submitted multimodal prediction result uses ground-truth prior seizure timestamps, whereas detection and the public-benchmark evaluations do not use TPS. This resolves the ambiguity in the current manuscript. The ground-truth-TPS configuration should be clearly described as an annotation-assisted or human-in-the-loop setting rather than a fully autonomous one. The planned online self-predicted-TPS result would be a useful additional evaluation of the autonomous setting, but I do not view it as necessary for validating the existing biosignal-only result. I consider Q3 largely resolved.\n\nQ4 — Can you report a strictly deployable setting?\n\nThe clarification that the KUK biosignal-only detection and prediction rows, as well as all CHB-MIT and Siena evaluations, use no clinical markers, notes, or ground-truth TPS substantially addresses my central deployment concern. I would suggest making the model-visible inputs explicit in the corresponding table captions and consistently distinguishing biosignal-only, annotation-assisted, and ground-truth-history settings to further improve clarity. I consider Q4 resolved.\n\nQ5 — Multi-quantile next-token loss.\n\nThank you for confirming that the model predicts a single shared embedding and that, with the final symmetric quantile configuration, the loss reduces to a robust L1-type objective rather than a genuine multi-quantile distributional prediction objective. This fully answers my question. The manuscript should correct the terminology and equation discussion accordingly, but I do not view this clarification as requiring the experiments to be rerun. I consider Q5 resolved.\n\nMetric-specific SOTA claim.\n\nI also appreciate the commitment to revise the SOTA claim so that it is metric-specific: NeuroNTP is strongest in AUROC and balanced accuracy under the reported public-dataset protocols, while CSBrain has the higher originally reported AUPRC. The corrected-label CHB-MIT analysis is interesting, but the resulting AUPRC should not be directly ranked against CSBrain unless both models are evaluated under the same corrected protocol.\n\nOverall, the rebuttal resolves most of my original concerns. The planned online self-predicted-TPS evaluation would be a useful addition for characterising a fully autonomous setting, while the existing biosignal-only prediction result already provides a no-TPS configuration. The revised manuscript should clearly distinguish biosignal-only, annotation-assisted, and human-in-the-loop settings."
+ },
+ "createdAt": "2026-07-30T11:48:53.332Z",
+ "modifiedAt": "2026-11-19T16:45:58.404Z",
+ "url": "https://openreview.net/forum?id=seM8LkgKy6&noteId=f5asxENwYY",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/sem8lkgky6/notes/gbkfotjs78.json added

+++ b/reviews/openreview/sem8lkgky6/notes/gbkfotjs78.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "gbkFoTjS78",
+ "replyTo": "OniUxFeCSv",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer idBm",
+ "content": {
+ "comment": "1. Thank you for clarifying and providing the additional results. The emphasized proximity-shaped supervision through TTS/TPS appears to be an important part of the contribution, and Table 13 provides useful evidence that it improves seizure-detection representations. Given this emphasis, I encourage the authors to revise the paper's framing so that this component and its role are clearly presented. At the same time, because TTS/TPS targets require seizure-timing annotations and are closely aligned with the downstream task, the paper should discuss the supervision and annotation requirements explicitly, particularly if this formulation is positioned as the core methodological novelty or as a pre-training strategy.\n\n I view the exact combination of modalities and the causal epilepsy-monitoring setting as a useful framework. However, multimodal physiological pre-training itself has been explored in representative models (e.g., SleepFM). Likewise, the three-stage scheme of tokenization, pre-training, and supervision is common in multimodal foundation models. Therefore, the paper would benefit from positioning its contribution more specifically as the integration of causal streaming and seizure-proximity supervision for multimodal epilepsy monitoring, while clearly distinguishing this application-specific contribution from broader claims of a new multimodal pre-training paradigm. Thus, the rebuttal partially addresses my novelty concern through the TTS/TPS component, while the broader novelty claims remain insufficiently differentiated from prior work.\n\n2. Promoting the montage-geometry method and its empirical impact to the main text, together with the proposed leave-montage-out evaluation, would adequately address this concern.\n\n3. I agree that NTP provides a natural inductive bias for predictive tasks and causal streaming. However, masked reconstruction and contrastive learning have also been successfully used for diagnosis and prediction in health applications. Moreover, masked reconstruction can be adapted to the same causal backbone, for example by reconstructing masked channels or modalities using only the available prefix. Therefore, a controlled comparison with alternative objectives would still help clarify the specific benefit of NTP, although I appreciate the authors' motivation for this design choice.\n\n4. These provide useful evidence that the gains are not solely attributable to the private KUK dataset. Together with the modality-ablation results and the planned data-fraction study, this largely addresses my concern regarding the source of the performance gains.\n\n5. Thank you for clarifying the motivation for xLSTM. The rebuttal provides a reasonable rationale for continuous seizure monitoring. Adding this architectural justification and relevant references would partially address my concern.\n\n6. I was not requesting that NeuroNTP be evaluated on unrelated physiological or BCI tasks. Rather, my question was whether existing multimodal physiological foundation models could be adapted and evaluated on the same seizure-related downstream tasks. Therefore, clarifying the epilepsy-specific scope does not fully address the baseline concern, although I agree that evaluation on unrelated tasks is unnecessary. At minimum, the paper should discuss the applicability of these models and include feasible comparisons with the most relevant ones."
+ },
+ "createdAt": "2026-07-29T14:05:07.916Z",
+ "modifiedAt": "2026-11-19T16:45:58.415Z",
+ "url": "https://openreview.net/forum?id=seM8LkgKy6&noteId=gbkFoTjS78",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/sem8lkgky6/notes/gsgsktq6te.json added

+++ b/reviews/openreview/sem8lkgky6/notes/gsgsktq6te.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "GSgSkTQ6tE",
+ "replyTo": "6n1D7diFz0",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer idBm",
+ "content": {
+ "comment": "I thank the authors for their response to my comments. Although my concerns have been partially addressed, some issues remain. Therefore, I will raise my score to weak reject."
+ },
+ "createdAt": "2026-08-04T09:45:20.295Z",
+ "modifiedAt": "2026-11-19T16:45:58.211Z",
+ "url": "https://openreview.net/forum?id=seM8LkgKy6&noteId=GSgSkTQ6tE",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/sem8lkgky6/notes/muruozp3bl.json added

+++ b/reviews/openreview/sem8lkgky6/notes/muruozp3bl.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "mUruozp3bl",
+ "replyTo": "f5asxENwYY",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Thank you for the close reading across both rounds and for confirming resolution on each point. We will make every distinction you ask for explicit in the revision. Concretely:\n\n**Consistent, explicit settings distinction.** We will make the model-visible inputs explicit and consistent for every reported result, so that readers can see at the point of reading what each configuration has access to. We will apply this distinction uniformly across the text, table captions, and figure legends, and finalize concise labels for these settings in the revision.\n\n**Q1 (KUK marker visibility).** Thank you for confirming that the marker-group decomposition is valuable. We will include it in the revised paper and specify the groups in enough detail for readers to see exactly what is visible in each condition, explicitly separating the deployment-valid configuration (EEG phenomena; seizure-event and delimiter markers such as Anfall, EEG-Beginn, EEG-Ende excluded) from the retrospective annotation-assisted setting.\n\n**Q2 (notes).** We will label the note-assisted results accordingly, and note that the biosignal-only and external-transfer results do not use these notes.\n\n**Q3 (TPS at test time).** We will describe the ground-truth-TPS multimodal prediction configuration as annotation-assisted / human-in-the-loop, and state clearly that detection and the CHB-MIT/Siena evaluations use **no additional modalities** than the biosignal channels in the reference protocols. The online self-predicted-TPS evaluation remains planned as a characterization of the fully autonomous setting.\n\n**Q4 (deployable setting).** Table captions for the KUK biosignal-only detection and prediction rows and for all CHB-MIT/Siena results will state **explicitly that no clinical markers, notes, or ground-truth TPS are used**, under the taxonomy above.\n\n**Q5 (multi-quantile loss).** We will correct the terminology and the Eq. 3 discussion to describe the objective accurately as a robust L1-type loss over a single shared predicted embedding, rather than multi-quantile distributional objective. \n\n**Metric-specific SOTA claim.** We will state the claim metric-specifically; NeuroNTP is strongest in AUROC and balanced accuracy under the reported public-dataset protocols, with CSBrain higher in AUPRC.\n\nWe appreciate the constructive engagement, which has materially sharpened how the deployment settings are presented."
+ },
+ "createdAt": "2026-08-04T09:38:46.151Z",
+ "modifiedAt": "2026-11-19T16:45:58.346Z",
+ "url": "https://openreview.net/forum?id=seM8LkgKy6&noteId=mUruozp3bl",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/sem8lkgky6/notes/ovau8dy5yb.json added

+++ b/reviews/openreview/sem8lkgky6/notes/ovau8dy5yb.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "OvAu8DY5yb",
+ "replyTo": "BP5JY5jVwK",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the Area Chair for the precise synthesis and the clear roadmap for acceptance. We have systematically addressed the core requirements across the individual rebuttals. Below is the executive summary of the new evidence and structural revisions we commit to for the final manuscript:\n## 1. Deployment-faithful evaluation (strict Biosignal-Only)\nCausal validity and strict biosignal evaluation is the concern we most want to correct a framing on, because we believe it rests on an under-stated protocol rather than a limitation of the results. \nOur central claims - SOTA transfer on CHB-MIT and Siena on AUROC - are already **strictly biosignal-only**: EEG input alone, with no clinical text, no markers, no notes, no TPS, no metadata (Appendices F.1/F.2). \nThe annotation-dependent configurations are confined to two explicitly-labelled KUK settings (one Table 1 detection row; Table 8 prediction) and are not part of the generalization claim. To make this explicit in the main text, we will:\n- **Decompose KUK clinical text by marker group:** and separate the seizure-derived markers, which we agree are not prospectively available, from the deployable configuration (YwCK Q1); \n- **Isolate annotation-dependent settings:** We will explicitly label the retrospective, human-in-the-loop KUK settings (Table 1; Table 8 prediction) to separate them from the generalization claim.\n- **Clarify TPS:** State that TPS is confined to multimodal prediction and computed from ground-truth timestamps, while adding an online self-predicted-TPS variant (YwCK Q3).\n## 2. Attribution of performance gains. \nWe disentangle performance as follows. \n- **Data scale:** NeuroNTP pretrained from scratch on the public TUSZ dataset still transfers to CHB-MIT and Siena, showing the gains are not merely KUK's scale (idBm Q4). A controlled 25/50/75/100% data-fraction experiment (s5Th Q1a) isolates the effect of pretraining scale under a fixed evaluation protocol; preliminary results are in our reply to the reviewer.\n- **Modality:** a multimodally-pretrained backbone evaluated on identical biosignal-only input consistently outperforms a biosignal-only-pretrained one - on CHB-MIT AUROC 92.5 vs 88.9, on Siena 91.5 vs 88.9, consistent with KUK (Appendix J) - isolating the value of pretraining-time enriched input that is absent at inference.\n- **Architecture:** matched-parameter xLSTM-vs-Transformer comparison (Appendix I.3). \n- **Objective:** the auxiliary-head ablation (Table 13), where removing the temporal-proximity objectives produces the two largest effects. \n## 3. Reposition novelty and montage generalization.\nWe concede the atomic components are established and reposition the contribution precisely.\n- **Technical Novelty:** causally-valid, constant-cost streaming inference over continuous multimodal clinical recordings, with a latent space shaped by temporal proximity to clinical events - a combination not provided by prior brain-signal foundation models.\n- **Baseline:** We include a differentiation table covering the multimodal and sub-quadratic models raised (idBm W1/W6). \n- **Montage generalization:** the frozen linear-probing transfer (Table 3) updates no montage-dependent parameters. Unseen electrodes are handled by replicating the spatially-nearest pretrained adapter with no gradient step. We will promote this to the main text, add a leave-montage-out evaluation, and position against seegnificant/PopT/BaRISTA (s5Th Q2/Q3).\n## 4. Reproducibility, Quantile loss, SOTA, comparability.\n- **Quantile Loss:** Eq. 3 reduces to a robust L1-type target given a single shared prediction and symmetric weights. We will correct the manuscript (YwCK Q5).\n- **SOTA adjustment:** we will state results metric-specifically. Best AUROC and BACC on both public datasets, CSBrain higher on reference-protocol AUPRC, and clarify the effect the augmentation protocol introduces (YwCK, metric-specific SOTA). \n- **Seizure Prediction:** We note that the review discussion has largely bypassed the considerably harder task of seizure prediction (Appendix Table 8). NeuroNTP consistently outperforms all other methods on this predictive task, and we will ensure this capability is properly emphasized in the text.\n- **Reproducibility:** While KUK cannot be released legally, we release pretrained models, full architecture/inference code, preprocessing pipelines, and TUSZ pretraining pipeline. The method is independently verifiable.\n- **Clarification:** We will correct the auxiliary-task reporting gap in §5.2.3 and the imprecise Transformer-complexity claims (s5Th).\n---\n*A Final Note of Gratitude*\nFinally, we want to thank the AC and reviewers for their valuable time. We are aware that this level of deep, constructive engagement is increasingly rare. The rigorous critique and actionable feedback have improved the structural rigor and clarity of this work. We deeply appreciate the effort invested by the reviewers and the opportunity to strengthen this manuscript."
+ },
+ "createdAt": "2026-08-04T10:18:04.605Z",
+ "modifiedAt": "2026-11-19T16:45:58.040Z",
+ "url": "https://openreview.net/forum?id=seM8LkgKy6&noteId=OvAu8DY5yb",
+ "license": "CC-BY-4.0"
+}