DARPAN: Controllability-Aware Residual Filtering for Pretrained Physical Control

Update NeurIPS 2026 submission QENhKkAMiO: 13 notes

@openreview[bot] · 2026-11-24 15:50 UTC · bb35d7088798 ·

Evidence

reviews/openreview/qenhkkamio/notes/0qsx65a9sv.json added

+++ b/reviews/openreview/qenhkkamio/notes/0qsx65a9sv.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "0QsX65A9sv",
+ "replyTo": "rWZaGXvZjd",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the reviewer for focusing on the generality and long-term robustness of the filter and adapter library.\n\n**Filter supervision.** The two environments use different supervision routes, but both estimate the same quantity: whether each residual component changes with the controller’s action. In BuildingEnv, this is learned from simulator counterfactuals without fault labels or access to the evaluation fault catalog. CogenEnv uses a fault-to-dimension mapping only because its ONNX interface does not support the same counterfactual procedure. We agree that the current paper does not yet demonstrate a single weakly supervised procedure for all physical systems.\n\n**Threshold sensitivity.** We use the same threshold, $c_{\\mathrm{filter}}=0.50$, in both environments. The mask is recomputed at every timestep, and the drift signature averages filtered residuals over $H=12$ steps, reducing the effect of isolated threshold errors. Our no-filter ablation provides an extreme boundary case: replacing the learned mask with an all-ones mask reduces recovery to $20.3\\pm3.4\\%$ and increases false creations from $1.20\\pm0.45$ to $30.60\\pm5.59$. However, this does not establish robustness to gradual threshold changes, and we will identify a controlled threshold-sensitivity study as important future work.\n\n**Long-term library behavior.** We agree that the 60-day and 14-day protocols do not establish behavior over arbitrarily long horizons or much larger drift catalogs. The current design limits unnecessary growth through filtered signatures, a similarity threshold of $\\tau=0.91$, a persistence requirement of $K_{\\mathrm{create}}=24$ steps, and a library capacity of $M_{\\max}=40$. Long-term uncontrollable deviations are primarily handled by the filter before adapter creation, as supported by the disturbance-only false-creation results above."
+ },
+ "createdAt": "2026-07-30T10:45:12.536Z",
+ "modifiedAt": "2026-11-19T17:04:04.519Z",
+ "url": "https://openreview.net/forum?id=QENhKkAMiO&noteId=0QsX65A9sv",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/qenhkkamio/notes/bc1s3hzu2h.json added

+++ b/reviews/openreview/qenhkkamio/notes/bc1s3hzu2h.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "bc1s3HzU2H",
+ "replyTo": "G1DxiAtcAT",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "## 5. Relationship to classical control\n\nWe agree that robust MPC, disturbance-observer-based control, and gain-scheduled control are important related approaches. The present evaluation asks a narrower controlled question: given the same pretrained Decision Transformer, which online adaptation mechanism best handles deployment drift while preserving the pretrained backbone? The learning-based baselines therefore share the same controller initialization and deployment data.\n\nA fair comparison with classical controllers would require environment-specific models, estimators, constraints, and tuning rather than changing only the adaptation mechanism. We will expand the discussion of this relationship and cite established robust and adaptive control approaches, while identifying a direct domain-specific comparison as important future work.\n\n## 6. Consistency corrections and evaluation scope\n\nWe will rename the vector-valued prediction residual as $e_{t+1}$ while retaining $r_t$ for reward and $R_t$ for return-to-go. The false-creation values in Tables 2 and 3 came from separate seed sets; we will consolidate both tables using the same run set. During disturbance-only phases, we use the unnormalized penalty difference\n\n$$ \\Delta P_{\\mathrm{dist}} = P_{\\mathrm{frozen}}-P_{\\mathrm{method}} $$\n\nwhere positive values indicate a lower penalty than the frozen controller. We will define this separately from normalized Recovery in the table caption and state the adapter-creation rule quantitatively.\n\nFinally, we agree that the current evidence is simulation-based and that OfficeSmall does not establish transfer across building architectures, climates, or physical deployments. We will state this scope more clearly. The current contribution is a controlled evaluation of selective deployment-time adaptation within a fixed pretrained system; real-building deployment, practitioner workflows, safety constraints, and evaluation across additional configurations remain important next steps."
+ },
+ "createdAt": "2026-07-30T11:08:39.664Z",
+ "modifiedAt": "2026-11-19T17:04:04.382Z",
+ "url": "https://openreview.net/forum?id=QENhKkAMiO&noteId=bc1s3HzU2H",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/qenhkkamio/notes/eb98u9wudx.json added

+++ b/reviews/openreview/qenhkkamio/notes/eb98u9wudx.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "eb98u9WUdx",
+ "replyTo": "wUyZ2y8NRc",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "---\n\n## Q5. Baseline tuning for Online PPO and Full Online DT\n\nWe clarify that the negative recovery values indicate failure to recover within the fixed deployment budget, rather than evidence that these methods cannot eventually adapt. Online PPO learned from scratch using a learning rate of $3\\times10^{-4}$, batch size $64$, $10$ optimization epochs, and $\\gamma=0.99$. Full Online DT was initialized from the same pretrained Decision Transformer and updated all $387{,}503$ parameters using AdamW with a learning rate of $10^{-5}$. We report the configurations used in our experiments and interpret the results within the same fixed deployment budget applied to all methods.\n\nBuildingEnv provides $288$ control steps per day and $17{,}280$ steps over 60 days, with each drift segment lasting only five days. CogenEnv is even more constrained, providing $96$ control steps per day and $1{,}344$ steps over the 14-day protocol, with most fault conditions lasting only one day. Thus, in both environments, an adaptation method must improve while the drift is active rather than relying on a long training horizon. Online PPO is included primarily as a from-scratch reference. The closer comparisons are Full Online DT, Online-Head DT, LoRA-DT, and Hyper-DT, which all begin from the same pretrained backbone.\n\n\nFull Online DT updates the entire controller from a short and non-stationary stream of deployment data. Its negative recovery is consistent with unrestricted updates overwriting useful pretrained behavior before sufficient online evidence is accumulated.\n\nTo verify that this is a time constraint rather than a tuning failure, we extended Full Online DT to 180 days of continuous operation (three times the protocol length, and approximately six months of real-world time), which raised recovery to roughly $10\\%$. The method does learn, it simply requires an adaptation window that is operationally unacceptable, since every month of adaptation is a month of degraded comfort or cost for the end user.\n\n\n---\n\n## Q6. The 63% claim clarification\n\nThe 63\\% reduction refers specifically to BuildingEnv, where DARPAN updates 142 parameters compared with 390 parameters for the Online-Head DT baseline, corresponding to 63.6\\% fewer trainable parameters. We agree that the original wording was ambiguous because Online DT could be interpreted as the full fine-tuning baseline. We wanted to compare with Online-Head DT because it is strongest competitor in terms of parameter cost. We will revise the abstract accordingly.\n\n---\n\n## Q7. Smaller actionable items\n\n\nWe address each of the five points below and will revise the manuscript accordingly.\n\n**[a] Identity of the short-horizon predictor.** The frozen predictor is a separately trained, action-conditioned one-step dynamics model. It is not the Decision Transformer's auxiliary multi-horizon state-prediction head. Only the standalone predictor participates in the deployment loop. We will clarify this in Section 3 and report its architecture and training configuration in the appendix.\n\n**[b] Notation overload.** We agree and will retain $r_t$ for the scalar reward and $R_t$ for return-to-go, while renaming the vector-valued prediction residual as $e_{t+1}$ throughout the paper.\n\n**[c] False-creation counts in Tables 2 and 3.** The values $1.20$ and $1.40$ were obtained from separate seed sets for the same DARPAN configuration. All variants within Table 3 were evaluated using a common run set, so its ablation comparisons remain internally consistent. In the revision, we will report both tables using a single consolidated run set.\n\n**[d] Recovery Change during disturbance-only phases.** During disturbance-only phases, the normalized Recovery metric is not applicable because there is no controllable drift-induced gap to recover. We therefore report the unnormalized penalty difference\n\n$$ \\Delta P_{\\mathrm{dist}} = P_{\\mathrm{frozen}} - P_{\\mathrm{method}} $$\n\nevaluated over the same disturbance phase. Positive values indicate a lower penalty than the frozen controller. We will distinguish this quantity from the normalized Recovery metric in the table caption.\n\n**[e] Adapter creation rule.** A drift signature is treated as novel when its cosine similarity to every stored adapter signature falls below $\\tau=0.91$. A new adapter is created only when this condition holds for $K_{\\mathrm{create}}=24$ consecutive control steps. Otherwise, the closest existing adapter is selected. We will add these values to the revised method description.\n\n---"
+ },
+ "createdAt": "2026-07-30T10:25:37.548Z",
+ "modifiedAt": "2026-11-19T17:04:04.674Z",
+ "url": "https://openreview.net/forum?id=QENhKkAMiO&noteId=eb98u9WUdx",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/qenhkkamio/notes/g1dxiatcat.json added

+++ b/reviews/openreview/qenhkkamio/notes/g1dxiatcat.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "G1DxiAtcAT",
+ "replyTo": "JQmXDQiuL0",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the Area Chair for the careful summary and for identifying the issues most important to the decision. To avoid duplicating the full reviewer responses, we summarize the corresponding clarifications, new analyses, and planned corrections below.\n\n\n## 1. Reproducibility and deployment hyperparameters\n\nWe agree that the deployment settings should have been stated explicitly. We now provide all values for both environments. The signature history is $H=12$, the filter threshold is $c_{\\mathrm{filter}}=0.50$, the cosine-similarity threshold is $\\tau=0.91$, and a new adapter is created after $K_{\\mathrm{create}}=24$ consecutive novel signatures. We use corrective strength $\\alpha=0.8$, correction penalty $\\lambda=10^{-3}$, and library capacity $M_{\\max}=40$.\n\nEach adapter is a one-hidden-layer MLP,\n$\\mathrm{Linear}(d_x,8)\\rightarrow\\mathrm{ReLU}\\rightarrow\\mathrm{Linear}(8,d_u)$,\nwith $(d_x,d_u)=(10,6)$ for BuildingEnv and $(44,15)$ for CogenEnv. This yields 142 and 495 online parameters, respectively. We will add the complete table to the revised appendix and shared code. Full details are provided in our response to m4CW Q1.\n\n## 2. Held-out CogenEnv filter evaluation\n\nWe clarify that the catalog-supervision concern applies specifically to CogenEnv. BuildingEnv trains the filter from simulator counterfactuals generated by varying actions and external conditions, without observing fault identities or using the evaluation fault catalog. CogenEnv uses fault-to-dimension supervision because its ONNX interface does not provide the same counterfactual reset capability.\n\nFollowing the suggested test, we are planning on conducting that experiment and retraining the CogenEnv filter after removing trajectories containing the wind-shift component and will evaluate it on the held-out wind-shift segments. We will compare recovery and false-adapter creations against the full-catalog filter and report the corresponding segment-level CogenEnv results. This directly tests whether the filter generalizes beyond residual patterns represented in its training catalog. Full details are provided in our response to m4CW Q2. We will update the results in the comments once the experiment is complete.\n\n## 3. Source of the remaining recovery gap\n\nWe computed BuildingEnv recovery separately for each fault segment across five runs. Recovery under weak actuation decreases with severity from $48.5\\pm1.6\\%$ to $28.0\\pm1.7\\%$ and $11.3\\pm2.0\\%$. Recovery is lower for stuck actuators at $8.9\\pm2.1\\%$ and $3.1\\pm1.4\\%$, while sensor-bias segments achieve $37.4\\pm1.1\\%$, $41.9\\pm4.4\\%$, and $48.2\\pm1.1\\%$. Compound-fault recovery is $31.3\\pm2.4\\%$, and short- and long-delay recovery are $63.3\\pm1.3\\%$ and $40.4\\pm14.9\\%$.\n\nThese results show that the remaining gap is not uniform. It is largest when actuator degradation physically restricts the available heating or cooling capacity, while sensor bias and shorter delay remain more recoverable. We provide the complete interpretation and delay diagnostic in our responses to m4CW Q3 and Q4. The corresponding CogenEnv segment-level values will be reported with the held-out-filter evaluation.\n\n## 4. Parameter claim, predictor identity, and baseline interpretation\n\nThe reported 63\\% reduction refers specifically to BuildingEnv relative to Online-Head DT, where DARPAN updates 142 parameters rather than 390, corresponding to 63.6\\% fewer online parameters. We will qualify the environment and baseline explicitly in the abstract. Relative to Full Online DT, which updates 387,503 parameters, the reduction is 99.96\\%.\n\nThe deployment predictor is a separately trained, action-conditioned one-step dynamics model. It is not the Decision Transformer’s auxiliary state-prediction head, and we will clarify this in Section 3.\n\nFor the negative-recovery baselines, we report the exact tested configurations and interpret the results only within the common deployment budget. BuildingEnv provides 17,280 interactions over 60 days, with each drift segment lasting five days; CogenEnv provides 1,344 interactions over 14 days, with most fault conditions lasting one day. Full Online DT was also extended to 180 days and reached approximately 10\\% recovery, showing that it can improve with additional interaction but remains substantially slower than DARPAN’s $31.7\\%$ recovery within the original protocol. We therefore do not claim that these baselines cannot eventually learn, only that they do not recover effectively within the evaluated deployment budget. Full details are provided in our responses to m4CW Q5-Q7."
+ },
+ "createdAt": "2026-07-30T11:08:09.007Z",
+ "modifiedAt": "2026-11-19T17:04:04.413Z",
+ "url": "https://openreview.net/forum?id=QENhKkAMiO&noteId=G1DxiAtcAT",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/qenhkkamio/notes/gjkeqlcqnf.json added

+++ b/reviews/openreview/qenhkkamio/notes/gjkeqlcqnf.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "GjkeqLcqnF",
+ "replyTo": "0QsX65A9sv",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer qw9L",
+ "content": {
+ "title": "Official comment by Reviewer qw9L",
+ "comment": "Dear authors:\n\n Thank you for the detailed reply. My three concerns were all satisfactorily addressed. Although, the method still has some limitations for Q2 as the authors honestly acknowledge. I will maintain my score but raise my confidence."
+ },
+ "createdAt": "2026-08-03T11:21:25.776Z",
+ "modifiedAt": "2026-11-19T17:04:04.364Z",
+ "url": "https://openreview.net/forum?id=QENhKkAMiO&noteId=GjkeqLcqnF",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/qenhkkamio/notes/haloyumvzh.json added

+++ b/reviews/openreview/qenhkkamio/notes/haloyumvzh.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "HalOYUmVZh",
+ "replyTo": "Aoy8V2tol2",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "### Question 2: Out-of-distribution evaluation of the CogenEnv filter.\n\nGiven the importance of this question, we expanded the leave-one-mechanism-out evaluation beyond the suggested wind-shift experiment to four distinct mechanism families, covering wind shift, sensor drift, GT1 degradation, and multi-turbine degradation. For each condition, we retrained the controllability filter from scratch after removing every filter-training trajectory containing the held-out mechanism, including all compound trajectories in which that mechanism appeared. The evaluated mechanism was completely absent from the filter-training data.\n\nThe filter is not given a fault identity or fault class. It computes a per-dimension controllability score directly from the current state, the applied base action, and the resulting prediction residual:\n\n$$p_{t+1} = C\\left(x_t, a_t^{\\mathrm{base}}, r_{t+1}\\right), \\qquad r_{t+1} = x_{t+1} - F\\left(x_t, a_t^{\\mathrm{base}}\\right)$$\n\n The results below show that exact exposure to the evaluated mechanism is not required, we will add this analysis to the revised manuscript.\n\n\n---\n**Table: Leave-one-mechanism-out evaluation of the CogenEnv controllability filter.** False adaptation rate is reported for exogenous segment that trigger an adapter update. Recovery is reported for controllable or compound segments.\n\n| Held-out mechanism | Evaluation segment | Metric | Full catalog | Held out |\n|---|---|---|:---:|:---:|\n| Wind shift | F5 | False adaptation rate (%) | 1.3 ± 0.5 | 3.4 ± 0.6 |\n| Wind shift | F7 | Recovery (%) | 48.5 ± 3.4 | 46.9 ± 6.8 |\n| Sensor drift | F3/F4 | False adaptation rate (%) | 2.6 ± 0.2 | 4.9 ± 0.3 |\n| Sensor drift | F8 | Recovery (%) | 46.0 ± 2.7 | 44.3 ± 3.2 |\n| GT1 degradation | F1 segments | Recovery (%) | 43.6 ± 3.3 | 46.1 ± 3.1 |\n| Multi-turbine degradation | F2 | Recovery (%) | 34.8 ± 2.3 | 34.2 ± 4.9 |\n| **Active-fault aggregate** | Controllable/compound segments | Recovery (%) | 38.4 ± 1.8 | 37.2 ± 3.9 |\n\nAggregation note. The final row reports penalty-gap-weighted recovery only over controllable and compound fault segments. The 28.5% result in Table 1 is computed from the full 14-day rollout. It also includes clean and exogenous segments, so it is lower than the active-fault result and is not an average of the segment-level percentages.\n\n---\n\nHolding out wind shift increased false adaptation on F5 from 1.3% to 3.4%, while holding out sensor drift increased it on F3/F4 from 2.6% to 4.9%. Even without these mechanisms in training, 96.6% and 95.1% of timesteps did not trigger an adapter update. Compound-fault recovery changed only slightly. F7 changed from 48.5% to 46.9%, and F8 changed from 46.0% to 44.3%. Recovery also remained stable for held-out controllable faults. GT1 degradation changed from 43.6% to 46.1%, and multi-turbine degradation changed from 34.8% to 34.2%. Overall active-fault recovery changed from 38.4% to 37.2%.\n\nComing to per fault recovery for Cogen, DARPAN achieves 42.3% recovery on mild GT1 degradation, 38.0% on severe GT1 degradation, 22.7% on HRSG fuel-response degradation, and 34.8% on multi-turbine degradation. Recovery remains strong on the compound F7 and F8 faults at 48.5% and 46.0%, respectively.The final recurring GT1 segment reaches 57.8%, consistent with reuse of an earlier adapter."
+ },
+ "createdAt": "2026-08-03T21:27:01.112Z",
+ "modifiedAt": "2026-11-19T17:04:04.335Z",
+ "url": "https://openreview.net/forum?id=QENhKkAMiO&noteId=HalOYUmVZh",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/qenhkkamio/notes/jqmxdqiul0.json modified

+++ b/reviews/openreview/qenhkkamio/notes/jqmxdqiul0.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair pUQw",
"content": {
- "metareview": "Summary: The paper proposes DARPAN, a framework for online adaptation of pretrained Decision Transformer controllers in physical control systems (building HVAC, cogeneration) subject to deployment-time drifts, e.g., actuator faults, sensor bias, delays, weather variation. They claim that adaptation should respond only to the action-sensitive portion of prediction error, i.e., residuals caused by controllable factors, while ignoring residuals from uncontrollable external disturbances. To this end, DARPAN freezes the pretrained backbone and uses a controllability filter (trained offline via counterfactual simulation) to score and mask prediction residuals. To validate their framework, the authors use the SustainGym's BuildingEnv and CogenEnv platforms. The evaluation under a 60-day rotating fault protocol reports recovery of 31.7% of drift-induced performance loss with substantially fewer online parameters than baselines. The ablation study demonstrates that each component (filter, history, expansion rule, adapter specialization) addresses a distinct failure mode.\n\nMain strengths:\n\n1) Online adaptation should be selective to distinguish controllable from uncontrollable residuals is principled and underexplored. The connection to matched vs. unmatched disturbances in classical control theory is apt.\n\n2) Each component (frozen backbone, controllability filter, drift signature, adapter library) has a clearly defined role. The ablation study in Table 3 shows qualitatively distinct failure modes when each component is removed, providing genuine design validation.\n\n3) Adapter sizes (142 and 496 parameters) are extremely small compared to the pretrained backbone, making deployment on edge hardware plausible.\n\n4) The 60-day rotating drift schedule with mixed and compound faults is more realistic than single-perturbation evaluations, and SustainGym is a credible domain benchmark.\n\nMain weaknesses\n\n1) Some critical hyperparameters are undisclosed based on Reviewers m4CW and qw9L. The filter threshold, history length, corrective strength, regularization weight, adapter MLP architecture, cosine similarity threshold, and persistence step count are all named but never assigned numerical values. Appendix F.5 discusses them qualitatively (\"if too low... if too high\") without giving the actual values. This fundamentally blocks reproducibility.\n\n2) For CogenEnv, the controllability filter is trained on labeled fault trajectories from the same catalog used in evaluation (Table 9). The strong results (e.g., 96% reduction in false creations) may reflect in-distribution pattern recognition rather than a general ability to separate controllable from external residuals. No held-out fault evaluation is provided.\n\n3) For a \"use-inspired\" contribution, the paper does not compare against standard robust/adaptive control strategies (disturbance-observer-based controllers, robust MPC, gain-scheduled controllers) that are widely used in HVAC and power systems and are also motivated by separating controllable and exogenous effects.\n\n4) Based on Reviewer m4CW, there are ambiguous and potentially misleading parameter claim. E.g, the abstract states \"63 percent fewer online parameters than an 'Online DT' baseline.\" This figure only holds when comparing DARPAN's BuildingEnv parameters (142) to Online-Head DT's BuildingEnv parameters (390). Compared to Full Online DT (387,503 params), the reduction is 99.96%. The abstract's wording is unqualified and environment-specific. It is also not clarified whether the frozen short-horizon predictor $\\hat{f}$ is the DT's own 1-step state head or a separately trained model. Online PPO and Full Online DT show negative recovery (worsening performance). This may reflect undertuning (e.g., inappropriate learning rates) rather than inherent limitations of online adaptation. No hyperparameter search details are provided. \n\n5) The evaluation is purely simulation-based, with no real-world data, practitioner engagement, or case study on in-the-field constraints. The building evaluation uses a single configuration (OfficeSmall), so generalizability across buildings, climates, or demand patterns is not established.\n\n6) Symbol $r$ is overloaded for both reward and residual; false creation counts differ between Tables 2 and 3; the \"Recovery change\" metric is undefined for disturbance-only phases; and the adapter creation rule is qualitatively described (\"persists for several steps\") without quantification.\n\nWeaknesses that need to be addressed in addition to the above:\n\n1. The authors must disclose numerical values for $c_\\text{filter}, \\alpha, H, \\lambda$, cosine similarity threshold, persistence criterion, and adapter MLP architectures for both environments. Without this, the method is not reproducible.\n\n2. The authors should evaluate the controllability filter on at least one drift type not represented in the training catalog (e.g., train the CogenEnv filter without wind shift faults and test on a wind shift segment). A positive result showing that the filter generalizes beyond its training distribution would substantially reduce concerns about in-distribution pattern matching.\n\n3. Reporting recovery separately for each fault segment (weak actuator, sensor bias, delay, stuck actuator, compound) would reveal where the remaining 68% performance gap originates. This would also clarify whether the predictor mismatch under delay is a critical limitation.\n\n4. The authors should also clarify the 63% claim in the abstract, reconcile the Table 2/3 false creation discrepancy, and provide baseline tuning details for Online PPO and Full Online DT to demonstrate that negative recovery is not due to undertuning, the paper could become more technically solid and sound."
+ "metareview": "Summary: The paper proposes DARPAN, a framework for online adaptation of pretrained Decision Transformer controllers in physical control systems (building HVAC, cogeneration) subject to deployment-time drifts, e.g., actuator faults, sensor bias, delays, weather variation. They claim that adaptation should respond only to the action-sensitive portion of prediction error, i.e., residuals caused by controllable factors, while ignoring residuals from uncontrollable external disturbances. To this end, DARPAN freezes the pretrained backbone and uses a controllability filter (trained offline via counterfactual simulation) to score and mask prediction residuals. To validate their framework, the authors use the SustainGym's BuildingEnv and CogenEnv platforms. The evaluation under a 60-day rotating fault protocol reports recovery of 31.7% of drift-induced performance loss with substantially fewer online parameters than baselines. The ablation study demonstrates that each component (filter, history, expansion rule, adapter specialization) addresses a distinct failure mode.\n\nMain strengths:\n\n1) Online adaptation should be selective to distinguish controllable from uncontrollable residuals is principled and underexplored. The connection to matched vs. unmatched disturbances in classical control theory is apt.\n\n2) Each component (frozen backbone, controllability filter, drift signature, adapter library) has a clearly defined role. The ablation study in Table 3 shows qualitatively distinct failure modes when each component is removed, providing genuine design validation.\n\n3) Adapter sizes (142 and 496 parameters) are extremely small compared to the pretrained backbone, making deployment on edge hardware plausible.\n\n4) The 60-day rotating drift schedule with mixed and compound faults is more realistic than single-perturbation evaluations, and SustainGym is a credible domain benchmark.\n\nMain weaknesses\n\n1) Some critical hyperparameters are undisclosed based on Reviewers m4CW and qw9L. The filter threshold, history length, corrective strength, regularization weight, adapter MLP architecture, cosine similarity threshold, and persistence step count are all named but never assigned numerical values. Appendix F.5 discusses them qualitatively (\"if too low... if too high\") without giving the actual values. This fundamentally blocks reproducibility.\n\n2) For CogenEnv, the controllability filter is trained on labeled fault trajectories from the same catalog used in evaluation (Table 9). The strong results (e.g., 96% reduction in false creations) may reflect in-distribution pattern recognition rather than a general ability to separate controllable from external residuals. No held-out fault evaluation is provided.\n\n3) For a \"use-inspired\" contribution, the paper does not compare against standard robust/adaptive control strategies (disturbance-observer-based controllers, robust MPC, gain-scheduled controllers) that are widely used in HVAC and power systems and are also motivated by separating controllable and exogenous effects.\n\n4) Based on Reviewer m4CW, there are ambiguous and potentially misleading parameter claim. E.g, the abstract states \"63 percent fewer online parameters than an 'Online DT' baseline.\" This figure only holds when comparing DARPAN's BuildingEnv parameters (142) to Online-Head DT's BuildingEnv parameters (390). Compared to Full Online DT (387,503 params), the reduction is 99.96%. The abstract's wording is unqualified and environment-specific. It is also not clarified whether the frozen short-horizon predictor $\\hat{f}$ is the DT's own 1-step state head or a separately trained model. Online PPO and Full Online DT show negative recovery (worsening performance). This may reflect undertuning (e.g., inappropriate learning rates) rather than inherent limitations of online adaptation. No hyperparameter search details are provided. \n\n5) The evaluation is purely simulation-based, with no real-world data, practitioner engagement, or case study on in-the-field constraints. The building evaluation uses a single configuration (OfficeSmall), so generalizability across buildings, climates, or demand patterns is not established.\n\n6) Symbol $r$ is overloaded for both reward and residual; false creation counts differ between Tables 2 and 3; the \"Recovery change\" metric is undefined for disturbance-only phases; and the adapter creation rule is qualitatively described (\"persists for several steps\") without quantification.\n\nWeaknesses that need to be addressed in addition to the above:\n\n1. The authors must disclose numerical values for $c_\\text{filter}, \\alpha, H, \\lambda$, cosine similarity threshold, persistence criterion, and adapter MLP architectures for both environments. Without this, the method is not reproducible.\n\n2. The authors should evaluate the controllability filter on at least one drift type not represented in the training catalog (e.g., train the CogenEnv filter without wind shift faults and test on a wind shift segment). A positive result showing that the filter generalizes beyond its training distribution would substantially reduce concerns about in-distribution pattern matching.\n\n3. Reporting recovery separately for each fault segment (weak actuator, sensor bias, delay, stuck actuator, compound) would reveal where the remaining 68% performance gap originates. This would also clarify whether the predictor mismatch under delay is a critical limitation.\n\n4. The authors should also clarify the 63% claim in the abstract, reconcile the Table 2/3 false creation discrepancy, and provide baseline tuning details for Online PPO and Full Online DT to demonstrate that negative recovery is not due to undertuning, the paper could become more technically solid and sound.",
+ "final_justification": "After careful consideration of the initial reviews, the authors' rebuttal, and the subsequent reviewer discussions, I think the reviewers were satisfied with the rebuttals and how the authors addressed their comments. Particularly, they have provided the specified hyperparameters and addressed the controllability filter. The quality of this paper has been improved. I think it reaches the acceptance bar."
},
"createdAt": "2026-07-15T13:17:33.535Z",
- "modifiedAt": "2026-11-18T15:19:05.282Z",
+ "modifiedAt": "2026-11-19T04:59:27.083Z",
"url": "https://openreview.net/forum?id=QENhKkAMiO&noteId=JQmXDQiuL0",
"license": "CC-BY-4.0"
}

reviews/openreview/qenhkkamio/notes/pcl3upmdxi.json added

+++ b/reviews/openreview/qenhkkamio/notes/pcl3upmdxi.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "PCL3upmdxI",
+ "replyTo": "G1DxiAtcAT",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Updates on Held-out CogenEnv filter evaluation: \nWe wanted to update on the experiment regarding held-out filter training. We expanded the leave-one-mechanism-out evaluation beyond the suggested wind-shift experiment to four distinct mechanism families, covering wind shift, sensor drift, GT1 degradation, and multi-turbine degradation. For each condition, we retrained the controllability filter from scratch after removing every filter-training trajectory containing the held-out mechanism, including all compound trajectories in which that mechanism appeared. The evaluated mechanism was completely absent from the filter-training data.\n\nThe filter is not given a fault identity or fault class. It computes a per-dimension controllability score directly from the current state, the applied base action, and the resulting prediction residual:\n\n$$p_{t+1} = C\\left(x_t, a_t^{\\mathrm{base}}, r_{t+1}\\right), \\qquad r_{t+1} = x_{t+1} - F\\left(x_t, a_t^{\\mathrm{base}}\\right)$$\n\n The results below show that exact exposure to the evaluated mechanism is not required, we will add this analysis to the revised manuscript.\n\n\n---\n**Table: Leave-one-mechanism-out evaluation of the CogenEnv controllability filter.** False adaptation rate is reported for exogenous segment that trigger an adapter update. Recovery is reported for controllable or compound segments.\n\n| Held-out mechanism | Evaluation segment | Metric | Full catalog | Held out |\n|---|---|---|:---:|:---:|\n| Wind shift | F5 | False adaptation rate (%) | 1.3 ± 0.5 | 3.4 ± 0.6 |\n| Wind shift | F7 | Recovery (%) | 48.5 ± 3.4 | 46.9 ± 6.8 |\n| Sensor drift | F3/F4 | False adaptation rate (%) | 2.6 ± 0.2 | 4.9 ± 0.3 |\n| Sensor drift | F8 | Recovery (%) | 46.0 ± 2.7 | 44.3 ± 3.2 |\n| GT1 degradation | F1 segments | Recovery (%) | 43.6 ± 3.3 | 46.1 ± 3.1 |\n| Multi-turbine degradation | F2 | Recovery (%) | 34.8 ± 2.3 | 34.2 ± 4.9 |\n| **Active-fault aggregate** | Controllable/compound segments | Recovery (%) | 38.4 ± 1.8 | 37.2 ± 3.9 |\n\nAggregation note. The final row reports penalty-gap-weighted recovery only over controllable and compound fault segments. The 28.5% result in Table 1 is computed from the full 14-day rollout. It also includes clean and exogenous segments, so it is lower than the active-fault result and is not an average of the segment-level percentages.\n\n---\n\nHolding out wind shift increased false adaptation on F5 from 1.3% to 3.4%, while holding out sensor drift increased it on F3/F4 from 2.6% to 4.9%. Even without these mechanisms in training, 96.6% and 95.1% of timesteps did not trigger an adapter update. Compound-fault recovery changed only slightly. F7 changed from 48.5% to 46.9%, and F8 changed from 46.0% to 44.3%. Recovery also remained stable for held-out controllable faults. GT1 degradation changed from 43.6% to 46.1%, and multi-turbine degradation changed from 34.8% to 34.2%. Overall active-fault recovery changed from 38.4% to 37.2%.\n\nComing to per fault recovery for Cogen, DARPAN achieves 42.3% recovery on mild GT1 degradation, 38.0% on severe GT1 degradation, 22.7% on HRSG fuel-response degradation, and 34.8% on multi-turbine degradation. Recovery remains strong on the compound F7 and F8 faults at 48.5% and 46.0%, respectively.The final recurring GT1 segment reaches 57.8%, consistent with reuse of an earlier adapter."
+ },
+ "createdAt": "2026-08-03T21:30:00.788Z",
+ "modifiedAt": "2026-11-19T17:04:04.447Z",
+ "url": "https://openreview.net/forum?id=QENhKkAMiO&noteId=PCL3upmdxI",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/qenhkkamio/notes/qqs6kz62h1.json added

+++ b/reviews/openreview/qenhkkamio/notes/qqs6kz62h1.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "qQS6kZ62h1",
+ "replyTo": "wOz69HTyUm",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "## Limitations\n\n### 1. Simulation-only evaluation\n\nWe agree that simulation-only evaluation is an important limitation. We view the present study as a controlled evaluation of selective deployment-time adaptation rather than a complete real-world control pipeline. Using BuildingEnv and CogenEnv allows us to introduce controllable faults, recurring drift, and exogenous disturbances reproducibly and to isolate the contribution of each adaptation component. \n\nBut we want to mention that these challenges are widely recognized in learning-based building control, where limited interaction data, occupant impact during learning, robustness, and building-specific deployment remain major barriers [1, 2]. Related work has demonstrated learning-based control on a physical data-center cooling system, but also highlights the additional care required for safe operation under limited data and unexpected events [3]. We will therefore make the present scope explicit and identify real-building evaluation, practitioner involvement, safety constraints, and comparison with established building-control approaches [4] as the next stage of this work.\n\n### 2. Dependence on offline filter supervision\n\nWe would clarify that DARPAN does not necessarily require a curated catalog of fault identities. In BuildingEnv, the filter is trained automatically from simulator counterfactuals by varying actions and external conditions, without observing the evaluation fault labels. CogenEnv uses a fault-to-state-dimension mapping because its ONNX interface does not provide the same counterfactual reset capability.\n\nPublic HVAC resources containing labeled faulted and fault-free operation from simulation, laboratory facilities, and measurements provide a concrete basis for studying data-driven filter supervision beyond a simulator catalog [5]. These resources do not remove the data requirement, but they provide a practical path toward training and evaluating controllability estimates from measured system trajectories. We are aware of these data availability and therefore we are confident that DARPAN can be useful in such scenarios. \n\n### 3. Single building configuration and architectural generality\n\nThe present scope is temporal adaptation of a fixed pretrained controller after deployment, rather than architectural transfer between systems. DARPAN is directly applicable to larger pretrained controllers, where its lightweight adapters can provide deployment-time corrections without updating the full backbone. Large-scale resources support pretraining and transfer studies across diverse building conditions. HOT provides approximately 150,000 building-weather configurations specifically for HVAC control-transfer research [6], BuildingsBench provides 900,000 simulated buildings for studying large-scale pretraining and transfer in building energy forecasting [7]. Pretrained sequence controllers have also begun to demonstrate transfer between simulated HVAC systems without updating their main network parameters [8].\n\n---\n#### References:\n\n[1] Zhe Wang and Tianzhen Hong. Reinforcement learning for building controls: The opportunities and challenges. Applied Energy, 269:115036, 2020.\n\n[2] Zoltan Nagy et al. Ten questions concerning reinforcement learning for building energy management. Building and Environment, 241:110435, 2023.\n\n[3] Nevena Lazic, Craig Boutilier, Tyler Lu, Eehern Wong, Binz Roy, M. K. Ryu, and Greg Imwalle. Data center cooling using model-predictive control. In Advances in Neural Information Processing Systems, volume 31, pages 3818–3827, 2018.\n\n[4] Ján Drgoňa, Javier Arroyo, Iago Cupeiro Figueroa, David H. Blum, Krzysztof Arendt, Donghun Kim, Enric Perarnau Ollé, Juraj Oravec, Michael Wetter, Draguna L. Vrabie, and Lieve Helsen. All you need to know about model predictive control for buildings. Annual Reviews in Control, 50:190–232, 2020.\n\n[5] Jessica Granderson, Guanjing Lin, Yimin Chen, Armando Casillas, Jin Wen, Zhelun Chen, Piljae Im, Sen Huang, and Jiazhen Ling. A labeled dataset for building HVAC systems operating in faulted and fault-free states. Scientific Data, 10:342, 2023.\n\n[6] Anaïs Berkes, Yoshua Bengio, David Rolnick, and Donna Vakalis. A HOT Dataset: 150,000 Buildings for HVAC Operations Transfer Research. In Proceedings of the 12th ACM International Conference on Systems for Energy-Efficient Buildings, Cities, and Transportation, pages 171–180, 2025.\n\n[7] Patrick Emami, Abhijeet Sahu, and Peter Graf. BuildingsBench: A Large-Scale Dataset of 900K Buildings and Benchmark for Short-Term Load Forecasting. In Advances in Neural Information Processing Systems, volume 36, pages 19823–19857, 2023.\n\n[8] Anaïs Berkes. HVAC-DPT: A Decision Pretrained Transformer for HVAC Control. arXiv preprint arXiv:2411.19746, 2024."
+ },
+ "createdAt": "2026-07-30T10:30:11.169Z",
+ "modifiedAt": "2026-11-19T17:04:04.577Z",
+ "url": "https://openreview.net/forum?id=QENhKkAMiO&noteId=qQS6kZ62h1",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/qenhkkamio/notes/reidd9ocab.json added

+++ b/reviews/openreview/qenhkkamio/notes/reidd9ocab.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "Reidd9Ocab",
+ "replyTo": "eb98u9WUdx",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "## Limitations\n\n\nWe will expand the limitations discussion to clarify the scope of the current formulation.\n\nFirst, the per-dimension controllability mask is an approximation in strongly coupled systems, where control effects and modeling errors may propagate across state dimensions [1]. A related ambiguity is already noted in Appendix F.6, which discusses cases where controllable faults and external disturbances produce nearly identical residuals in the observed state. We will move this point into the main limitations discussion and identify state-dependent or cross-dimensional controllability estimation as a natural extension.\n\nSecond, the current one-step predictor and state-conditioned adapter do not explicitly model recent action history. Delay can change the temporal structure of the control problem and may require delay-aware state representations or predictors [2,3]. As discussed in our response to Q4, DARPAN retains positive recovery under both short and long delays, but the current analysis does not isolate the predictor-gradient effect. We will therefore describe temporal mismatch as a limitation of the current formulation rather than draw a stronger causal conclusion.\n\nThird, CogenEnv uses fault-to-dimension supervision because its ONNX interface does not support the counterfactual procedure used in BuildingEnv. Its generalization to fault components absent from that catalog requires direct evaluation, which is the purpose of the held-out wind-shift experiment described above. Public HVAC datasets containing faulted and fault-free trajectories from simulation, laboratory facilities, and field operation [4] also provide useful data sources for studying filter supervision from measured system trajectories.\n\nFinally, we agree that normalized recovery does not by itself provide a complete operational interpretation. DARPAN is intended to apply beyond a single environment-specific objective, so we use recovery to measure the fraction of the Frozen-DT-to-reference penalty gap closed and to enable consistent comparison across environments with different objective scales and penalty definitions.\n\n---\n#### References:\n\n\n[1] Ercan Atam. Decentralized thermal modeling of multi-zone buildings for control applications and investigation of submodeling error propagation. Energy and Buildings, 126:384–395, 2016.\n\n[2] Jean-Pierre Richard. Time-delay systems: An overview of some recent advances and open problems. Automatica, 39(10):1667–1694, 2003.\n\n[3] Pierre Liotet, Davide Maran, Lorenzo Bisi, and Marcello Restelli. Delayed reinforcement learning by imitation. In Proceedings of the 39th International Conference on Machine Learning, pages 13528–13556, 2022.\n\n[4] Jessica Granderson, Guanjing Lin, Yimin Chen, Armando Casillas, Jin Wen, Zhelun Chen, Piljae Im, Sen Huang, and Jiazhen Ling. A labeled dataset for building HVAC systems operating in faulted and fault-free states. Scientific Data, 10:342, 2023."
+ },
+ "createdAt": "2026-07-30T10:29:09.241Z",
+ "modifiedAt": "2026-11-19T17:04:04.578Z",
+ "url": "https://openreview.net/forum?id=QENhKkAMiO&noteId=Reidd9Ocab",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/qenhkkamio/notes/rwzagxvzjd.json added

+++ b/reviews/openreview/qenhkkamio/notes/rwzagxvzjd.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "rWZaGXvZjd",
+ "replyTo": "5F3hM2HM6n",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the reviewer for raising important questions about DARPAN’s robustness under imperfect filtering and routing.\n\n---\n\n## Question 1: When the filter mistakenly suppresses the truly controllable residual dimensions, how will DARPAN recover?\n\nThe filter decision is recomputed at every timestep from the current state, action, and residual, so mistakenly suppressing a controllable dimension once does not remove it permanently. If that dimension is recognized as controllable at later steps, it again contributes to the filtered residual and the adapter can resume learning from it. The drift signature also aggregates the filtered residual over $H=12$ steps, which limits the influence of isolated masking errors.\n\nIf the filter persistently suppresses that dimension, it will not contribute to adapter routing or updating, reducing the achievable recovery on that component. This is a conservative failure mode because DARPAN forgoes adaptation from the suppressed signal rather than directly adapting to a component judged uncontrollable. Persistent false suppression therefore limits recovery and remains an important source of filter error.\n\n\n\n---\n\n## Question 2: When the new drift mode partially overlaps with the historical mode but is not exactly the same, is the current cosine-similarity routing prone to mistakenly reusing the adapter?\n\n\nPartial overlap can cause an existing adapter to be selected, but this does not necessarily constitute incorrect reuse. DARPAN compares drift signatures in filtered-residual space and reuses an adapter only when the cosine similarity exceeds $\\tau=0.91$, indicating that the new drift has a closely aligned filtered-residual signature with a historical mode. The selected adapter continues to be updated online, allowing it to adjust to differences in the new drift. If the new signature remains below the similarity threshold for $K_{\\mathrm{create}}=24$ consecutive steps, DARPAN creates a separate adapter. Therefore, continued adaptation and persistent-novelty detection reduce the risk of unsuitable reuse. However, a partially overlapping drift that remains above the similarity threshold may continue to reuse the same adapter, which we recognize as a limitation of the current routing rule.\n\n\n---\n\n## Question 3: If there are long-term but uncontrollable systematic deviations during the deployment process, will DARPAN continue to accumulate invalid adapters, or will the merge mechanism be sufficient to control the degradation of the library?\n\nLong-term uncontrollable deviations are primarily handled by the controllability filter rather than by the merge mechanism. Because non-action-sensitive residuals are suppressed before the drift signature is formed, they should not repeatedly trigger adapter creation. In our disturbance-only evaluation, DARPAN produced only $1.20 \\pm 0.45$ false creations, compared with $30.60 \\pm 5.59$ when the filter was removed, showing that filtering substantially limits unnecessary library growth. The current evaluations therefore indicate that filtering is the main safeguard against invalid adapter accumulation, while the library-capacity and merge rules provide an additional bound on library growth."
+ },
+ "createdAt": "2026-07-30T10:35:39.897Z",
+ "modifiedAt": "2026-11-19T17:04:04.553Z",
+ "url": "https://openreview.net/forum?id=QENhKkAMiO&noteId=rWZaGXvZjd",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/qenhkkamio/notes/woz69htyum.json added

+++ b/reviews/openreview/qenhkkamio/notes/woz69htyum.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "wOz69HTyUm",
+ "replyTo": "7jf5Z5c1Ar",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the reviewer for the constructive feedback for recognizing the value of selective adaptation and parameter efficiency. The questions on engineering overhead and robustness to filter quality help us position the practical contribution more clearly and identify the most important next evaluation.\n\n---\n\n## Q1. It would help to have a more explicit discussion (or experiment) on the engineering overhead versus simpler schemes such as robust pretraining with broader fault-domain randomization or straightforward online-head adaptation with carefully tuned regularization.\n\nThe frozen controller already receives broad pretraining the BuildingEnv data include varied operating conditions and fault-wrapped trajectories from the same broad fault families used in evaluation. DARPAN's gains therefore do not arise simply from comparing against a narrowly pretrained controller.\n\nThe distinction is that pretraining determines what the controller knows before deployment, whereas DARPAN determines what it should learn from after deployment. A fixed pretrained policy cannot incorporate a new correction from deployment data, and a generic online update does not distinguish correctable error from external variation. DARPAN adds selective learning from action-sensitive residuals and stores separate corrections for reuse when drift returns.\n\nWe compare directly with the simpler Online-Head DT under the same pretrained backbone and deployment data. In BuildingEnv, DARPAN achieves\n$31.7 \\pm 1.1\\%$ recovery with 142 online parameters, compared with $20.1 \\pm 2.4\\%$ using 390 parameters for Online-Head DT. Replacing the adapter\nlibrary with one global adapter further reduces recovery to $8.4 \\pm 1.5\\%$. Thus, the additional components provide selective adaptation and memory, rather than simply adding model capacity.\n\n\n--- \n\n## Q2 Could you add an experiment where the filter is intentionally perturbed (e.g., trained on a mismatched simulator, corrupted labels, or systematically biased mask) to quantify how sensitive performance and false-adaptation behavior are to filter quality, and to show whether the method degrades gracefully as the filter becomes less accurate?\n\nThis is a valuable suggestion, however, a multi-level study would require retraining the filter under several levels of label corruption or simulator mismatch and rerunning the full deployment protocol for each level. We cannot complete this study reliably within the rebuttal period, but we will state this limitation clearly and identify graded filter-quality sensitivity analysis as important future work. \n\nOur existing no-filter ablation provides an informative extreme boundary case. Replacing the learned mask with an all-ones mask reduces recovery to $20.3 \\pm 3.4%$ and increases false adapter creations from $1.20 \\pm 0.45$ to $30.60 \\pm 5.59$. Thus, removing filter selectivity substantially reduces recovery and causes unnecessary library growth, while the remaining components still retain positive recovery. This ablation does not establish how performance changes under gradual filter corruption, and we will state that distinction clearly and include controlled filter-quality sensitivity as an important extension."
+ },
+ "createdAt": "2026-07-30T10:24:30.902Z",
+ "modifiedAt": "2026-11-19T17:04:04.684Z",
+ "url": "https://openreview.net/forum?id=QENhKkAMiO&noteId=wOz69HTyUm",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/qenhkkamio/notes/wuyz2y8nrc.json added

+++ b/reviews/openreview/qenhkkamio/notes/wuyz2y8nrc.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "wUyZ2y8NRc",
+ "replyTo": "Aoy8V2tol2",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the reviewer for these specific and constructive questions. We address each point below. \n## Q1. Deployment hyperparameters\n\n| Symbol | Meaning | BuildingEnv | CogenEnv |\n|---|---|---|---|\n| $H$ | Signature history length | 12 | 12 |\n| $c_{\\mathrm{filter}}$ | Controllability filter threshold | 0.50 | 0.50 |\n| $\\tau$ | Cosine similarity threshold (adapter matching) | 0.91 | 0.91 |\n| $K_{\\mathrm{create}}$ | Persistence step count (adapter creation rule) | 24 | 24 |\n| $\\alpha$ | Corrective strength | 0.8 | 0.8 |\n| $\\lambda$ | Correction-size penalty | $10^{-3}$ | $10^{-3}$ |\n| $M_{\\max}$ | Adapter library capacity | 40 | 40 |\n| — | Adapter hidden width | 8 | 8 |\n| $d_x$ | Adapter input dimension | 10 | 44 |\n| $d_u$ | Adapter output dimension | 6 | 15 |\n| — | Adapter parameter count | 142 | 495 |\n\nThe adapter architecture is identical across environments: a single hidden layer of width 8, $\\mathrm{Linear}(d_x, 8) \\rightarrow \\mathrm{ReLU} \\rightarrow \\mathrm{Linear}(8, d_u)$. All deployment hyperparameters above are shared across both environments; the two differ only in input/output dimensions, yielding 142 parameters for BuildingEnv and 495 for CogenEnv (correcting a minor typo in our original 496). $K_{\\mathrm{create}} = 24$ quantifies the adapter creation rule described qualitatively in the submission. The $M_{\\max}$ capacity bound is disabled in the naive-expansion ablation.\n\n## Q2. Out-of-distribution filter evaluation\n\nWe first clarify that this concern applies to the CogenEnv. In BuildingEnv, the filter is trained entirely from simulator counterfactuals by varying actions and external conditions, without observing fault identities or using the evaluation fault catalog. CogenEnv uses fault-to-dimension supervision only because its ONNX interface does not provide the same counterfactual reset capability.\n\nFollowing the reviewer’s suggestion, we are working on this experiment by removing all trajectories containing the wind-shift component, including standalone F5 and compound F7, while retaining standalone F1 turbine-degradation data. We will compare recovery and false-adapter creations against the full-catalog filter, and provide the corresponding segment-level CogenEnv recovery values and update the results in the comments once the experiment is complete.\n\n## Q3. Per-fault-type recovery breakdown\n\nWe measured recovery separately for each fault segment across five runs.\n\n**Weak actuation.** Recovery decreases as the fault becomes more severe $48.5 \\pm 1.6\\%$ (mild), $28.0 \\pm 1.7\\%$ (medium), and $11.3 \\pm 2.0\\%$ (severe). When a severe fault limits a heater to a fraction of its nominal capacity, the adapter outputs a large compensatory correction that pushes the command toward the relevant action limit. Because the actuator itself is degraded, however, even the limiting command cannot restore the lost thermodynamic capacity. \n**Stuck actuators.** Recovery is $8.9 \\pm 2.1\\%$ (moderate) and $3.1 \\pm 1.4\\%$ (strong). A stuck actuator substantially restricts or removes control over the affected channel, so a correction in that dimension has little or no effect on its output.\n\n**Sensor bias.** Recovery is $37.4 \\pm 1.1\\%$, $41.9 \\pm 4.4\\%$, and $48.2 \\pm 1.1\\%$ across the three segments. The increase to $48.2\\%$ occurs on a recurrence of the warmer bias.\n\n**Compound faults.** $31.3 \\pm 2.4\\%$.\n\n**Action delay.** Recovery is $63.3 \\pm 1.3\\%$ (short delay) and $40.4 \\pm 14.9\\%$ (long delay).\n\nThis result must be interpreted alongside the absolute loss of physical control capacity. We want to give an illustrative example here, suppose a severe fault limits a heater to $30\\%$ of its nominal capacity. At time $t$, zone 1 is at $19.5^\\circ\\mathrm{C}$ with a target of $21.0^\\circ\\mathrm{C}$. The frozen Decision Transformer requests a strong heating action, $a_t^{\\mathrm{base}}[1]=0.85$. The adapter correctly recognizes the under-response from the drift signature and outputs a large compensatory correction, $\\Delta a_t[1]=0.40$. The deployed action hits the physical upper bound: $a_t[1]=\\mathrm{clip}(0.85+0.40)=1.0$. However, because the actuator is severely damaged, this maximum command only raises the temperature to $T_1(t+1)=19.7^\\circ\\mathrm{C}$. \n\n## Q4. Predictor gradient under actuation delay\n\nDARPAN does not model actuation delay because the adapter computes $\\Delta a_t=f(x_t)$ from the current state without directly conditioning on recent action history.The temporal drift signature summarizes filtered residual steps for adapter selection, and the online correction remains empirically useful($63.3\\pm1.3%$ recovery under the short delay and $40.4\\pm14.9%$ under the longer delay). To examine whether temporal predictor mismatch specifically reduces recovery, we repeated the long-delay segment with the delay removed while holding the remaining conditions fixed. Recovery was $42.0\\pm5.6%$, compared with $40.4\\pm14.9%$ under delay."
+ },
+ "createdAt": "2026-07-30T10:22:24.846Z",
+ "modifiedAt": "2026-11-19T17:04:04.685Z",
+ "url": "https://openreview.net/forum?id=QENhKkAMiO&noteId=wUyZ2y8NRc",
+ "license": "CC-BY-4.0"
+}