potentialpaper

Ultra Fast PDE Solving via Physics Guided Few-step Diffusion

Update NeurIPS 2026 submission XQGamZ3x8F: 22 notes

@openreview[bot] · 2026-11-24 15:52 UTC · 243165bd8b8c ·

Evidence

reviews/openreview/xqgamz3x8f/notes/0939ctve2v.json added

+++ b/reviews/openreview/xqgamz3x8f/notes/0939ctve2v.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "0939CTvE2V",
+ "replyTo": "XbRsH9nQR0",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer obxi",
+ "content": {
+ "title": "Answer to authors' rebuttal",
+ "comment": "I thank the authors for answering all my questions and the upcoming modifications that will help improve the manuscript. Here are some follow-ups answers/questions. \n\n2 / Q1. Thanks for the additional re-solve audit, which helps assessing the fidelity of the method. I agree with your observations regarding the fidelity of the PDE residual and I shoudl this could be stated in the manuscript (in a limitation section for instance). How costly is the re-solve experiment on the poisson equation ? \n\n3 / Q2. Thanks for all these precision. Just being curious, but have you observed cases where the physical guidance lead to wrong solution ? (for instance a minimized PDE residual for a null solution ?)\n\n4 / Q4. Regarding the provided results, does it mean that the method kind of « overfits » on the number of allowed steps ? Beyond the steps budget, the prediction degrades or stabilizes ? \n\n5/ Q3, Q5. My question here was rather to understand why, based on the state of the litterature, going toward flow matching rather that diffusion, did this manuscript still focused on diffusion. Since this is a design choice, why not using directly flow matching ? \nRegarding the table 11, I am not necessarily asking to add tons of baselines as it is not the concern of the paper. However, table 11 is not reliable and up-to-date as is, since all baselines are very very old. It does not bring a fair comparison with the deterministic setting as the field has evolved a lot. This table compares methods from 5 years ago with a brand new model. I do not necessary ask for new experiment now as the rebutal period is advancing, however, in the final version, a fair comparison with deterministic baselines should be to show that the related claim holds."
+ },
+ "createdAt": "2026-07-31T07:48:01.142Z",
+ "modifiedAt": "2026-11-19T16:59:30.188Z",
+ "url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=0939CTvE2V",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xqgamz3x8f/notes/1i6r5rpmjj.json added

+++ b/reviews/openreview/xqgamz3x8f/notes/1i6r5rpmjj.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "1i6R5RPmJJ",
+ "replyTo": "uydpjaogvy",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Reviewer KTwv [1/4]",
+ "comment": "# Response to Reviewer KTwv [1/4]\n\nWe thank the reviewer for the detailed and constructive assessment and for recognizing the importance, clarity, and strong low-step performance of Phys-Instruct. The review also raises the central scientific question behind our contribution: beyond the headline speedup, what does physics-guided distillation change, what is lost under compression, and when are those losses recovered? We organize our response around the mechanism, the resulting trade-offs, and the expanded scope of the evaluation.\n\n## 1. Novelty and what physics-guided distillation preserves, loses, and recovers (W1; Q5, Q6)\n\n**The novelty of Phys-Instruct is a principled way to amortize PDE correction into a reusable one-/few-step generative solver.** Starting from IKL distribution matching, we derive a tractable generator update that jointly performs teacher–student distribution alignment and explicit sample-level PDE guidance. The physics signal is therefore incorporated during distillation rather than applied as inference-time correction; after training, the student requires neither the teacher nor the PDE evaluator and can be reused as a generative prior for downstream tasks.\n\nThe reviewer’s suggestion motivated a deeper analysis of **what aggressive compression changes**. We presented teacher (4, 200 steps) & student (1-4 steps) latency-PDE Error trade off (Fig.1) and distribution discrepancy (SWD,MMD) compared to left out ground truth on Burgers’ benchmark (Fig.3), showing distribution discrepancy improvement with increasing $k$, though still slightly worse than 200 step teacher. Here we extend $k$ to 8 and add more metrics to further analyze distribution matching and sample diversity. Sec/sample measures latency; SWD measures discrepancy to held-out data, showing distribution-level accuracy measures; kNN Recall measures support coverage; Diversity/T200 measures retained sample-to-sample variation relative to 200 step teacher (EDM). \n\n| Model | $k$ | sec/sample | PDE Error | SWD | Recall | Diversity/T200 |\n|---|---:|---:|---:|---:|---:|---:|\n| Phys-Instruct (ours) | 1 | 0.012 | 0.171 | 0.071 | 0.674 | 0.658 |\n| -- | 2 | 0.036 | 0.118 | 0.060 | 0.830 | 0.896 |\n| -- | 4 | 0.084 | 0.055 | 0.049 | 0.930 | 0.890 |\n| -- | 8 | 0.225 | 0.046 | 0.046 | 0.919 | 0.905 |\n| EDM | 200 | 4.919 | 0.860 | 0.043 | 0.980 | 1.000 |\n\nAt one step, Burgers shows some reduction in support coverage and spread. Most of this gap is recovered by $k=2$–$4$: at $k=4$, recall reaches 0.930, Diversity/T200 reaches 0.890, and SWD approaches EDM-200 (0.049 versus 0.043), while PDE Error remains substantially lower (0.055 versus 0.860). At $k=8$, PDE Error, SWD, and diversity improve only modestly, while recall decreases slightly. MMD follows the same trend as SWD. Thus, the student does not uniformly dominate the teacher: physics guidance improves equation consistency, while aggressive compression introduces a measurable but controllable distributional cost. \n\n## 2. How should $k$ be chosen, and is it related to the teacher's sampling steps? (W7, Q6)\nThere is no fixed teacher–student step ratio. The EDM teacher is continuous in noise level, and 200 steps is only the numerical budget used to obtain a strong reference. Phys-Instruct learns a new $k$-step transport rather than truncating a 200-step teacher trajectory; $200/k$ therefore indicates inference speedup, not a required relationship between the two step counts.\n\nLarger $k$ decomposes the noise-to-sample mapping into smaller updates, reducing the approximation burden at each step, but also increases latency and yields marginal gains. In practice, we evaluate a small grid such as $k\\in\\{1,2,4,8\\}$ and select the smallest $k$ that provides a satisfactory balance among PDE Error, distribution quality, and latency. On Burgers, most gains are obtained by $k=4$; this is a practical observation rather than a universal optimum."
+ },
+ "createdAt": "2026-07-29T18:09:48.364Z",
+ "modifiedAt": "2026-11-19T16:59:30.347Z",
+ "url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=1i6R5RPmJJ",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xqgamz3x8f/notes/9m7oxsjcmb.json added

+++ b/reviews/openreview/xqgamz3x8f/notes/9m7oxsjcmb.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "9M7oXsjcmB",
+ "replyTo": "pimSylYKPL",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Reviewer nE2R [2/2]",
+ "comment": "# Response to Reviewer nE2R [2/2]\n## 3. Does the conditional model retain uncertainty, and does distillation reduce diversity? (W3)\n\nWe separate **downstream predictive uncertainty** from the **direct distributional effect of unconditional distillation**.\n\n**Downstream UQ.** We evaluate 10 held-out Poisson-forward cases under identical partial 5% observations, draw 50 conditional samples per case, and compute metrics only at unobserved locations.\n\n| Method | Steps | CRPS $\\downarrow$ | Empirical 90% coverage |\n|---|---:|---:|---:|\n| DiffusionPDE | 2000 | 0.0080 | 92.84% |\n| Phys-Instruct (ours) | 1 | **0.0066** | 89.08% |\n\nPhys-Instruct achieves lower CRPS, while its coverage remains close to the nominal 90% level. Thus, the final one-step conditional model retains useful predictive uncertainty and does not show severe over concentration in this test. We do not claim exact posterior recovery.\n\nThis is an end-to-end conditional UQ comparison rather than an isolated distillation experiment: DiffusionPDE uses inference-time DPS, whereas Phys-Instruct uses a trained conditional branch on the distilled backbone.\n\n**Direct effect of distillation.** On unconditional Burgers generation, SWD measures discrepancy from held-out data, kNN Recall measures support coverage, and Diversity/T200 measures sample-to-sample variation relative to EDM-200.\n\n| Model | $k$ | PDE Error $\\downarrow$ | SWD $\\downarrow$ | Recall $\\uparrow$ | Diversity/T200 $(\\to1)$ |\n|---|---:|---:|---:|---:|---:|\n| Phys-Instruct (ours) | 1 | 0.171 | 0.071 | 0.674 | 0.658 |\n| -- | 2 | 0.118 | 0.060 | 0.830 | 0.896 |\n| -- | 4 | 0.055 | 0.049 | 0.930 | 0.890 |\n| -- | 8 | 0.046 | 0.046 | 0.919 | 0.905 |\n| EDM | 200 | 0.860 | 0.043 | 0.980 | 1.000 |\n\n**Phys-Instruct is not pure teacher imitation**: The IKL term aligns the student with the teacher distribution, while PDE guidance adds a sample-level equation-consistency objective during distillation. The student can therefore achieve lower PDE Error than the teacher without being expected to reproduce the teacher exactly. \n\nAt 1 step, the distillation produces measurable contraction in support and spread. Most of this gap is recovered by $k=2$–$4$: at $k=4$, recall reaches 0.930, Diversity/T200 reaches 0.890, and SWD approaches EDM-200 (0.049 versus 0.043), while PDE Error remains much lower (0.055 versus 0.860). Thus, the student’s advantage is metric-specific: physics guidance improves equation consistency, while the distributional cost of aggressive compression is largely recovered with a modest step budget. The results do not indicate that the lower PDE Error is obtained through severe distribution collapse.\n\n## 4. Are backbone capacity and evaluation protocols comparable across methods? (Q2)\n\nYes, EDM, DiffusionPDE, CoCoGen, PIDM, and Phys-Instruct use the same 54.41M-parameter SongUNet backbone. The Phys-Instruct teacher, student, and training-only auxiliary each use this architecture; downstream conditional tasks additionally train a 22.44M control branch.\n\nDiffusionPDE applies DPS at inference; CoCoGen adds inference-time refinement based on DiffusionPDE; PIDM incorporates physics during training using the same benchmark-specific residual evaluator as Phys-Instruct; Phys-Instruct incorporates physics during distillation with EDM as the teacher. \nWe use released or official checkpoints from DiffusionPDE [1] paper where applicable. All paired comparisons use the same test instances, conditioning inputs, and metric implementations. We will make these protocol differences and capacity controls more explicit.\n\n## 5. How sensitive is Phys-Instruct to $\\lambda_{\\mathrm{phys}}$, and is one value used across PDEs? (Q3)\n\n**$\\lambda_{\\mathrm{phys}}$ is task-specific, but training is reasonably robust once its scale is chosen appropriately.** We use $5\\times10^{-3}$ for Darcy, $10^{-2}$ for Poisson and Navier–Stokes, $10^{-3}$ for Helmholtz and Burgers, and $10^{-4}$ for Kolmogorov. A universal value is not appropriate because the operators, normalization, discretization, and gradient scales differ across tasks.\n\nAppendix G.1 reports the full Darcy ablation and a practical tuning procedure. We did not perform a full sweep for every PDE, but all reported task-specific weights trained stably. In practice, we use a short warm-up run to ensure that the physics update is neither negligible nor dominant relative to distribution matching, followed by only a small local adjustment if necessary. \n\n## Conclusion\n\nThese added checks corroborate the original evaluation across independent solvers, higher resolutions, downstream UQ, and unconditional diversity. We will make the residual definitions, higher-resolution evidence, baseline protocols, and claim boundaries more explicit in the revision.\n\n## References\n[1] DiffusionPDE, NeurIPS 2024"
+ },
+ "createdAt": "2026-07-29T18:16:06.458Z",
+ "modifiedAt": "2026-11-19T16:59:30.301Z",
+ "url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=9M7oXsjcmB",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xqgamz3x8f/notes/a07ylapcon.json modified

+++ b/reviews/openreview/xqgamz3x8f/notes/a07ylapcon.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair NqvE",
"content": {
- "metareview": "The paper proposes Phys-Instruct, which distills a pretrained diffusion PDE solver into a one-/few-step generator while adding differentiable PDE-residual guidance during training. Results on five benchmarks report substantially faster inference, lower residuals, and transfer to conditional forward and inverse tasks.\n\nThe paper focuses on the speed–physics trade-off, provides a coherent derivation, and demonstrates strong performance in the low-step regime. The theoretical analysis is also included.\n\nThe main concern is that PDE residual alone may not reliably establish solution fidelity, conservation, or uncertainty preservation. The evaluation also lacks sufficient evidence on complex temporal PDEs, higher-resolution settings, sparse/OOD observations, diversity after distillation, and comparisons with the closest recent methods. Thus, these clarifications should be included: (i) a stronger case would require evidence that lower residuals correspond to genuinely accurate physical solutions, (ii) clarification of diversity, robustness, baseline fairness, training cost, and novelty.\n\nCurrent recommended category: Papers that need clarification."
+ "metareview": "The paper proposes Phys-Instruct, which distills a pretrained diffusion PDE solver into a one-/few-step generator while adding differentiable PDE-residual guidance during training. Results on five benchmarks report substantially faster inference, lower residuals, and transfer to conditional forward and inverse tasks.\n\nThe paper focuses on the speed–physics trade-off, provides a coherent derivation, and demonstrates strong performance in the low-step regime. The theoretical analysis is also included.\n\nThe main concern is that PDE residual alone may not reliably establish solution fidelity, conservation, or uncertainty preservation. The evaluation also lacks sufficient evidence on complex temporal PDEs, higher-resolution settings, sparse/OOD observations, diversity after distillation, and comparisons with the closest recent methods. Thus, these clarifications should be included: (i) a stronger case would require evidence that lower residuals correspond to genuinely accurate physical solutions, (ii) clarification of diversity, robustness, baseline fairness, training cost, and novelty.\n\nCurrent recommended category: Papers that need clarification.",
+ "final_justification": "I have read the authors' response and the subsequent discussion. The rebuttal substantially addressed the main concerns raised in my initial meta-review, including the relationship between PDE residual and solution fidelity, diversity and uncertainty after distillation, evaluation on more complex temporal PDEs and sparse/OOD settings, as well as baseline fairness and training cost. The additional experiments and analyses significantly strengthen the empirical support for the proposed framework.\n\nWhile the methodological novelty remains moderate, I find the combination of physics-guided distillation and few-step generative PDE solving technically meaningful, with strong practical benefits and a thorough evaluation. The remaining concerns do not outweigh these strengths, and I therefore recommend acceptance. I also note the citation-checker flag regarding the incorrect author list for the cited “One-Step Diffusion Distillation through Score Implicit Matching” paper, which should be corrected in the final version."
},
"createdAt": "2026-07-14T01:09:44.409Z",
- "modifiedAt": "2026-11-18T15:19:12.739Z",
+ "modifiedAt": "2026-11-19T04:59:32.806Z",
"url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=a07yLapCon",
"license": "CC-BY-4.0"
}

reviews/openreview/xqgamz3x8f/notes/darpk2yrkw.json added

+++ b/reviews/openreview/xqgamz3x8f/notes/darpk2yrkw.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "DArPk2yrkw",
+ "replyTo": "uydpjaogvy",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Reviewer KTwv [3/4]",
+ "comment": "# Response to Reviewer KTwv [3/4]\n\n## 5. Can Phys-Instruct handle sparse forward/inverse problems beyond Burgers, and does it preserve downstream UQ? (W4; Q3, Q5)\n\nWe added a 2D Poisson experiment with 5% randomly observed grid points. The mask and observed values are supplied to one conditional model, which handles forward and inverse problems by changing which field is observed.\n\n| Method | Steps | Forward Rel. Error $\\downarrow$ | Forward PDE Error $\\downarrow$ | Inverse Rel. Error $\\downarrow$ | Inverse PDE Error $\\downarrow$ |\n|---|---:|---:|---:|---:|---:|\n| DiffusionPDE | 2000 | 14.40% | 0.339 | 32.42% | 0.0604 |\n| Phys-Instruct (ours) | 1 | **12.97%** | **0.286** | **26.70%** | **0.0493** |\n\nThus, the one-step model improves both reference and PDE errors on sparse forward and inverse tasks beyond the Burgers setting. We do not claim exhaustive sparse evaluation over every PDE listed by the reviewer.\n\nWe also evaluate downstream predictive uncertainty on 10 held-out Poisson-forward cases, drawing 50 samples per condition and scoring only unobserved locations.\n\n| Method | Steps | CRPS $\\downarrow$ |\n|---|---:|---:|\n| DiffusionPDE | 2000 | 0.0080 |\n| Phys-Instruct (ours) | 1 | **0.0066** |\n\nPhys-Instruct achieves lower CRPS and 89.08% empirical coverage for a nominal 90% interval, compared with 92.84% for DiffusionPDE. The final one-step conditional model therefore retains useful predictive uncertainty.\n\nBecause the two methods use different conditional mechanisms, this comparison evaluates downstream UQ rather than isolating the effect of distillation alone.\n\n## 6. Robustness to noisy observations and OOD coefficient statistics (W5; Q5) \n\nWe evaluate the Darcy $32\\times32$ forward problem under two controlled shifts. For noisy setup, we randomly flip 5% of the binary permeability labels (binary label noise). For OOD setup, we shifted the GRF correlation length from $\\ell=3.5$ to 5, each shifted coefficient field is independently re-solved to obtain its reference solution.\n\n| Setting | Phys-Instruct-1 Rel./PDE Error | DiffusionPDE-2000 Rel./PDE Error |\n|---|---:|---:|\n| Clean | **0.29% / 0.28** | 4.61% / 0.53 |\n| 5% label flips | **2.84% / 1.24** | 9.24% / 1.79 |\n| $\\ell=5$ | **0.94% / 0.42** | 14.00% / 0.77 |\n\nPhys-Instruct remains more accurate under both shifts. The $\\ell$-shift is a valid coefficient-distribution test because the complete coefficient field is still supplied to both methods; only its spatial statistics change. We did not vary viscosity or wavenumber because these are fixed PDE parameters and are not inputs to the current models. Changing them would alter the governing operator without informing Phys-Instruct, and therefore represents a different operator-conditioning problem rather than the controlled robustness test considered here.\n\n## 7. Is one physics weight used across PDEs, and would different schedules improve training? (W7)\n\n**$\\lambda_{\\mathrm{phys}}$ is task-specific, but training is reasonably robust once its scale is chosen appropriately.** We use $5\\times10^{-3}$ for Darcy, $10^{-2}$ for Poisson and Navier–Stokes, $10^{-3}$ for Helmholtz and Burgers, and $10^{-4}$ for Kolmogorov.\n\nAppendix G.1 reports the full Darcy ablation and a practical tuning procedure. We did not perform a full sweep for every PDE, but all reported task-specific weights trained stably. In practice, we use a short warm-up run to ensure that the physics update is neither negligible nor dominant relative to distribution matching, followed by only a small local adjustment if necessary. Adaptive weighting can be a useful extension, but was not evaluated here."
+ },
+ "createdAt": "2026-07-29T18:06:03.792Z",
+ "modifiedAt": "2026-11-19T16:59:30.383Z",
+ "url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=DArPk2yrkw",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xqgamz3x8f/notes/ddtsnh4owp.json added

+++ b/reviews/openreview/xqgamz3x8f/notes/ddtsnh4owp.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "DDTSNh4owp",
+ "replyTo": "uydpjaogvy",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Reviewer KTwv [4/4]",
+ "comment": "# Response to Reviewer KTwv [4/4]\n\n## 8. Closest recent work, model size, and training cost (W1, W8; Q4)\n\n**Closest recent method.** Yao et al. is relevant and already cited, but it uses a function-space diffusion prior with iterative inference-time guidance, whereas Phys-Instruct performs training-time distillation of a fixed-grid pretrained teacher. A controlled comparison would require a matched function-space teacher and representation; otherwise representation, teacher, and sampler would change simultaneously. We will clarify this relationship and identify function-space Phys-Instruct as an extension.\n\n**Model size.** The teacher and student each use the same 54.41M-parameter SongUNet backbone. \n\n**Training cost.** Phys-Instruct incurs a one-time distillation overhead; we do not claim lower training cost.\n\n| Benchmark | EDM pretraining | Phys distillation | Total |\n|---|---:|---:|---:|\n| Darcy | 689.4 | 506.9 | 1196.3 |\n| Poisson | 689.4 | 506.9 | 1196.3 |\n| Navier–Stokes | 1609.0 | 1191.1 | 2800.1 |\n\nAll values are training compute in kTFLOPs. For Burgers and Helmholtz, the pretrained checkpoints were inherited, so the teacher totals are unavailable; the measured distillation costs are 3185.3 and 3364.9 kTFLOPs, respectively.\n\nThe intended trade-off is a one-time training overhead for repeated one-/few-step inference without test-time PDE correction and for reuse of the resulting generative prior across downstream tasks.\n\n## Conclusion\n\nThe additional analyses do more than add benchmarks: they reveal the mechanism and practical behavior of physics-guided distillation. They show what aggressive compression costs in support and diversity, how a modest step budget recovers most of that cost, and how the resulting prior behaves under independent physical audits, complex temporal dynamics, sparse observations, and controlled distribution shifts.\n\nWe will incorporate these analyses and discussions into the revision. Together, they clarify and substantiate the originality of Phys-Instruct as a principled physics-guided distribution-matching framework and make its compute–quality–diversity trade-off and scope substantially clearer."
+ },
+ "createdAt": "2026-07-29T18:03:54.486Z",
+ "modifiedAt": "2026-11-19T16:59:30.427Z",
+ "url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=DDTSNh4owp",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xqgamz3x8f/notes/dgmqgcgsbw.json added

+++ b/reviews/openreview/xqgamz3x8f/notes/dgmqgcgsbw.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "DgMqgcGsBw",
+ "replyTo": "DDTSNh4owp",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer KTwv",
+ "content": {
+ "comment": "Thank you for your responses! I acknowledge the thorough rebuttal done by the authors and all the experiments included during this phase. A lot of my concerns regarding more empirical evidence have been resolved. Finally, I think that the paper is good and I am impressed by the speed improvement in the inference using diffusion models; however, I am still hesitant because of the novelty of this work. Distillation using physics loss right now seems more of an engineering solution than a novel research work. I agree novelty is not the only criterion for acceptance, but in that case, having insights into the method and its various plugs is necessary. While some of those do get answered in the form of ablation experiments, adding something like why physics guidance in teh form of residual works when it works and why it does not work when it does not."
+ },
+ "createdAt": "2026-08-02T02:34:19.468Z",
+ "modifiedAt": "2026-11-19T16:59:30.262Z",
+ "url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=DgMqgcGsBw",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xqgamz3x8f/notes/djlyv0nr91.json added

+++ b/reviews/openreview/xqgamz3x8f/notes/djlyv0nr91.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "DjlYv0NR91",
+ "replyTo": "a07yLapCon",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Area Chair,\n\nThank you for the careful meta-review. For ease of review, we summarize below how each concern is addressed in the reviewer responses, without repeating the full protocols and tables.\n\n## 1. Do lower PDE errors correspond to solution fidelity & improved conservation?\n\n**Our additional evaluations provide direct evidence that, on the tested benchmarks, lower PDE errors are accompanied by improved solution accuracy, conservation diagnostics, or independently evaluated physical consistency.**\n\nOn Poisson, Phys-Instruct-4step improves a held-out fourth-order residual together with independently re-solved $L^2$ and $H^1$ errors over teacher 200 step. Burgers further shows improved mass and viscous energy-balance defects, while the new Kolmogorov experiment shows lower independently dealiased spectral residuals and improved spectrum structure.\n\nThese results show that the improvement is not limited to the residual formula used during training. We do not claim residual and solution error are universally equivalent.\n\n**See:** Reviewer nE2R [1/2], Sec. 1; Reviewer KTwv [2/4], Sec. 4; Reviewer obxi [1/3], Sec. 2.\n\n## 2. Are diversity and uncertainty preserved after distillation?\n\nThe new $k=1,2,4,8$ Burgers analysis shows that 1-step distillation causes measurable contraction in distribution and sample diversity, but most of this gap is recovered by $k=2$–$4$. We report a controllable compute-quality-diversity trade-off rather than claiming lossless distillation. For downstream UQ under 5% partial Poisson observations, Phys-Instruct-1 achieves 89.08% coverage for a nominal 90% interval, indicating that the 1-step conditional model retains useful predictive uncertainty without severe over-concentration.\n\n**See:** Reviewer KTwv [1/4], Secs. 1–2; Reviewer nE2R [2/2], Sec. 3.\n\n## 3. What evidence covers temporal dynamics and higher resolutions?\n\nThe higher-resolution evidence was already present in the submission: Appendix F.2 provides matched generative comparisons with the corresponding EDM teacher at $128^2$, $256^2$, and $512^2$. To address the temporal-PDE concern, we additionally trained and distilled a Kolmogorov model that evaluates the complete local-in-time vorticity equation. At 8 steps, Phys-Instruct reduces PDE Error and independently evaluated Spectral PDE Error compared to EDM-200.\n\n**See:** Reviewer nE2R [1/2], Sec. 2; Reviewer KTwv [2/4], Sec. 3.\n\n## 4. How does the method behave under sparse, corrupted, and OOD inputs?\n\nIn addition to the existing sparse-observation Burgers experiment, we added a 2D Poisson task with 5% randomly observed grid points. A single conditional model handles both forward and inverse problems, and Phys-Instruct-1 improves both reference and PDE errors over DiffusionPDE-2000. On Darcy, it remains more accurate under 5% binary permeability-label flips and under a held-out GRF correlation-length shift from $\\ell=3.5$ to 5, with each shifted coefficient independently re-solved.\n\n**See:** Reviewer KTwv [3/4], Secs. 5–6.\n\n## 5. What is the novelty, and how does Phys-Instruct differ from the closest methods?\n\nPhys-Instruct addresses a specific problem: distilling a pretrained generative model on PDE into a reusable one-/few-step generator while improving equation consistency and removing inference-time PDE correction. Starting from IKL distribution matching, we derive a generator update that combines teacher–student distribution alignment with explicit sample-level PDE guidance. The physics correction is therefore amortized into the student parameters. The generator can be reused as a generative prior for downstream tasks.\n\nThis differs from generic Diff-Instruct, which provides the IKL foundation but no PDE guidance; from DiffusionPDE and CoCoGen, which apply physics correction during inference; from PIDM, which trains a physics-informed generative model in one stage rather than distilling an existing prior; and from Yao et al., which uses a function-space prior with iterative inference-time guidance. \n\n**See:** Reviewer obxi [2/3], Sec. 5-6; Reviewer KTwv [1/4], Sec. 1 and [4/4], Sec. 8.\n\n## 6. Are the comparisons fair, and what is the training cost?\n\nThe main diffusion-based comparisons use the same 54.41M-parameter SongUNet backbone and matched evaluation protocols. Phys-Instruct adds a one-time distillation stage, so we do not claim lower training cost; the benefit is repeated one-/few-step inference without test-time PDE correction.\n\n**See:** Reviewer obxi [3/3], Sec. 7; Reviewer nE2R [2/2], Sec. 4; Reviewer KTwv [4/4], Sec. 8.\n\n\n## Summary\n\nOverall, the reviewer responses provide the requested evidence and clarifications on solution accuracy, diversity and uncertainty, broader evaluation scope, baseline fairness, training cost, and novelty. We hope these responses address the concerns raised in the meta-review.\n\nThank you again for your consideration."
+ },
+ "createdAt": "2026-07-30T20:09:45.713Z",
+ "modifiedAt": "2026-11-19T16:59:30.259Z",
+ "url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=DjlYv0NR91",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xqgamz3x8f/notes/gn7ou54ojx.json added

+++ b/reviews/openreview/xqgamz3x8f/notes/gn7ou54ojx.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "Gn7ou54Ojx",
+ "replyTo": "uQsPO11BoE",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer KTwv",
+ "content": {
+ "comment": "Thank you for the update on insights and recommendations. I will consider this when updating my final justification."
+ },
+ "createdAt": "2026-08-03T20:36:11.178Z",
+ "modifiedAt": "2026-11-19T16:59:29.950Z",
+ "url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=Gn7ou54Ojx",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xqgamz3x8f/notes/hqfdngbeiv.json added

+++ b/reviews/openreview/xqgamz3x8f/notes/hqfdngbeiv.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "hQFDNGbeIv",
+ "replyTo": "XbRsH9nQR0",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Followup [1/2]",
+ "comment": "# Response to Followup [1/2]\n\nDear Reviewer,\n\nThanks for the thoughtful follow-up and positive assessment of our rebuttal. We clarify the remaining points below.\n\n## 2/Q1: Scope of PDE Error and cost of the Poisson re-solve check\n\nWe agree that the scope of PDE Error should be stated explicitly in the discussion/limitations of the final version. It measures discrete equation consistency, but does not by itself guarantee solution accuracy; independent re-solving therefore provides complementary validation.\n\nThe numerical Poisson re-solve takes approximately 1.07 ms per generated forcing field on an NVIDIA RTX 5070 Ti GPU. This check is used only for offline validation of generated forcing–solution pairs and is not part of Phys-Instruct training or inference.\n\n## 3/Q2: Can physics guidance favor an incorrect solution?\n\nWithin the guidance-weight range that produced converged training, we did not observe collapse to null or constant solutions. The IKL term discourages collapse toward such low-residual solutions by aligning the joint distribution of PDE input and solution fields with the pretrained teacher.\n\nWith an excessively large physics weight, however, the physics update can overwhelm IKL distribution matching, causing unstable training and diversity collapse. In the failed Darcy runs corresponding to Appendix G.1, Table 8, we observed nearly identical or nearly constant outputs. We treat these as non-converged runs; they are readily identified by monitoring the training objectives and generated-sample diversity. This is why physics guidance must remain balanced with IKL distribution alignment rather than optimized alone.\n\nAmong converged models, the closest case was Poisson-1, where the held-out residual improved before the independent re-solve $L^2/H^1$ errors were fully recovered; at four steps, both improved over EDM-200."
+ },
+ "createdAt": "2026-08-01T17:29:53.856Z",
+ "modifiedAt": "2026-11-19T16:59:30.490Z",
+ "url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=hQFDNGbeIv",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xqgamz3x8f/notes/hw5rfurtva.json added

+++ b/reviews/openreview/xqgamz3x8f/notes/hw5rfurtva.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "hw5rfUrtVA",
+ "replyTo": "NkJbPjcc8q",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Thank you very much for your response and consideration. Should any further questions arise before the discussion period concludes, we would be glad to discuss them and do our best to address any remaining concerns."
+ },
+ "createdAt": "2026-07-30T17:02:40.637Z",
+ "modifiedAt": "2026-11-19T16:59:30.264Z",
+ "url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=hw5rfUrtVA",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xqgamz3x8f/notes/iutfiriusa.json added

+++ b/reviews/openreview/xqgamz3x8f/notes/iutfiriusa.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "IuTFIrIUsa",
+ "replyTo": "SIcI5SLSrT",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer obxi",
+ "content": {
+ "comment": "Thanks for these lasts elements. I have already updates my review and my score."
+ },
+ "createdAt": "2026-08-04T11:19:22.329Z",
+ "modifiedAt": "2026-11-19T16:59:29.928Z",
+ "url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=IuTFIrIUsa",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xqgamz3x8f/notes/l0crfapjoz.json added

+++ b/reviews/openreview/xqgamz3x8f/notes/l0crfapjoz.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "l0CrFApjOZ",
+ "replyTo": "mTNmf0vDEN",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Reviewer obxi [1/3]",
+ "comment": "# Response to Reviewer obxi [1/3]\n\nWe thank the reviewer for the constructive assessment and for recognizing the theoretical foundation and broad empirical evaluation of Phys-Instruct. The questions mainly concern the clarity of the training pipeline, the scope of PDE Error, stability, behavior beyond 4 steps, comparison with other model classes, training cost, and the practical role of the generative prior. We address each point directly below and will revise the presentation, terminology, and limitations accordingly.\n\n## 1. What does each network receive during training and inference, and how will Figure 2 be corrected? (W1; M1)\n\n**The teacher and auxiliary receive the generated-and-noised state $x_t$, not external physical fields.** During distillation, $z,k \\rightarrow g_\\theta \\rightarrow x_0$,\nand the forward diffusion maps $x_0$ to $x_t$. The frozen teacher and online auxiliary both receive $(x_t,t)$; the auxiliary is updated by denoising score matching. The generator update combines the stopped score-difference gradient with the PDE gradient evaluated on $x_0$, and the PDE term updates only the generator.\n\nDuring inference, only the student is used; the teacher, auxiliary, and PDE evaluator are absent. Downstream conditional tasks retain the 1-step backbone and train an added ControlNet branch. Figure 2 did not make these data flows sufficiently clear, and we will revise its arrows and labels.\n\n## 2. Does lower PDE Error imply lower solution error? (Q1)\n\n**Not necessarily; PDE Error and reference-solution error measure different properties, and we report them separately whenever paired targets are available.** On the Darcy $32\\times32$ forward task, their sample-wise association is positive but weak (Pearson $r=0.350$, Spearman $\\rho=0.291$). We also observe method-level decoupling on Helmholtz: CoCoGen reduces PDE Error from 1.48 to 1.07 relative to DiffusionPDE, while relative prediction error is essentially unchanged (9.70% versus 9.69%). Thus, a lower residual does not necessarily imply a proportional reduction in prediction error.\n\nFor unconditional generation, each sample defines a new PDE input–solution pair and has no preassigned target. We therefore added an independent Poisson re-solve audit. At one step, Phys-Instruct has a lower held-out FD4 residual than EDM-200 ($2.758\\times10^{-2}$ versus $4.228\\times10^{-2}$) but higher re-solve $L^2/H^1$ errors ($2.680\\times10^{-2}/3.661\\times10^{-2}$ versus $1.253\\times10^{-2}/1.509\\times10^{-2}$), showing that the metrics can decouple under aggressive compression. At four steps, however, Phys-Instruct improves all three metrics and beat teacher: FD4 residual $5.763\\times10^{-3}$, re-solve $L^2$ $6.742\\times10^{-3}$, and re-solve $H^1$ $6.487\\times10^{-3}$.\n\nPDE Error remains valuable because it directly measures equation consistency and provides a differentiable sample-level signal when paired targets are unavailable. Our conclusions do not infer solution accuracy from residual alone: conditional tasks report both metrics, while unconditional tests independently verifies the generated PDE pairs.\n\n## 3. Can the physics term destabilize training? (Q2)\n\n**Yes, if it is over-weighted; within the tested range, however, training is stable.** Phys-Instruct does not optimize the PDE residual alone: the IKL term keeps the student aligned with the frozen teacher distribution, while the physics term reduces equation violations. Instability can arise when the physics update overwhelms this balance.\n\nAppendix G.1 reports that the Darcy model trains stably for $\\lambda_{\\mathrm{phys}}\\in[10^{-3},10^{-2}]$, with PDE Errors 0.359, 0.315, and 0.318 at $10^{-3}$, $5\\times10^{-3}$, and $10^{-2}$. The default $5\\times10^{-3}$ performs best. Increasing the weight to $5\\times10^{-2}$ causes divergence, while very small values provide insufficient guidance. Applying guidance from the beginning also performs better than late activation (0.315 versus 0.407); removing guidance gives 8.75.\n\nStability is further supported by teacher initialization, a frozen teacher, explicit boundary enforcement, benchmark-consistent residual discretization, and a task-scaled physics weight. We do not claim stability for arbitrary weights or PDE conditioning, but the existing ablation identifies a clear practical operating range."
+ },
+ "createdAt": "2026-07-29T17:54:02.278Z",
+ "modifiedAt": "2026-11-19T16:59:30.425Z",
+ "url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=l0CrFApjOZ",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xqgamz3x8f/notes/ndckc8yy6v.json added

+++ b/reviews/openreview/xqgamz3x8f/notes/ndckc8yy6v.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "nDCKc8Yy6v",
+ "replyTo": "pimSylYKPL",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Reviewer nE2R [1/2]",
+ "comment": "# Response to Reviewer nE2R [1/2]\n\nWe thank the reviewer for the careful and constructive assessment and for recognizing the mathematical derivation, broad PDE evaluation, and strong low-step performance of Phys-Instruct. The main questions concern the scope and implementation of PDE Error, whether the reported gains persist under independent physical checks and higher resolutions, whether conditional uncertainty or unconditional diversity is reduced, and whether the baseline and hyperparameter comparisons are fair. The analyses below broaden and corroborate the original evaluation without changing our central claims.\n\n## 1. What does PDE Error measure, how is it computed, and do the gains persist under independent physical checks? (W1, Q1)\n\n**PDE Error directly measures discrete equation consistency, which is the property targeted by the physics guidance.** For the teacher–student evaluation, each generated sample is a new unconditional PDE input–solution pair with no preassigned reference solution. We therefore evaluate the per-sample residual RMS in physical units and average it over generated samples to calculate PDE Error, using the same benchmark-specific evaluator for every method.\n\n| Benchmark | PDE evaluator | Reference-data solver |\n|---|---|---|\n| Darcy | Conservative flux-form residual $\\nabla\\!\\cdot(a\\nabla u)+1$, with harmonic face averaging | Sparse variable-coefficient finite-difference elliptic solver; homogeneous Dirichlet boundary |\n| Poisson | $\\Delta u-a$, using a second-order five-point Laplacian | Sparse five-point finite-difference Dirichlet solver |\n| Navier–Stokes | Released terminal-state proxy $D_x\\omega_T+D_y\\omega_T$ | Dealiased Fourier pseudo-spectral vorticity solver |\n| Burgers | $D_tu+uD_xu-\\nu D_{xx}u$, using centered finite differences with $\\nu=0.01$ | Periodic Chebfun spectral solver for the full trajectory |\n| Helmholtz | $\\Delta u+u-a$, using a second-order five-point Laplacian | Sparse finite-difference Helmholtz solver |\n\nFollowing the reviewer’s suggestion, we add targeted checks for discretization dependence, excessive smoothing, conservation/balance, and spectral structure.\n\nFor Poisson, we independently re-solve every generated forcing and compare the generated solution and gradients with the numerical solution. We also use a held-out fourth-order residual not used during training.\n\n| Method | Steps | Held-out FD4 $\\downarrow$ | Re-solve $L^2$ $\\downarrow$ | Re-solve $H^1$ $\\downarrow$ |\n|---|---:|---:|---:|---:|\n| Phys-Instruct (ours) | 4 | **$5.763\\times10^{-3}$** | **$6.742\\times10^{-3}$** | **$6.487\\times10^{-3}$** |\n| EDM | 200 | $4.228\\times10^{-2}$ | $1.253\\times10^{-2}$ | $1.509\\times10^{-2}$ |\n\nPhys-Instruct-4 reduces the held-out residual by 86%, the re-solve $L^2$ error by 46%, and the re-solve $H^1$ error by 57% compared to EDM-200. The improvement therefore persists under a different discretization and is accompanied by more accurate solution values and gradients.\n\nFor Burgers, Phys-Instruct-4 reduces the mass-conservation defect from $1.336\\times10^{-2}$ to $1.193\\times10^{-2}$, and the viscous energy-balance defect from $2.969\\times10^{-1}$ to $1.016\\times10^{-1}$, relative to EDM-200.\n\nFor the newly added $Re=1000$ Kolmogorov-flow benchmark (as suggested by Reviewer KTwv), at the same 8-step budget, Phys-Instruct reduces PDE Error from 150.2 to 18.86, an independently evaluated dealiased Spectral PDE Error from 106.13 to 17.09, and radial-spectrum mismatch from 1.880 to 0.291. Its PDE and Spectral PDE Errors are also lower than EDM-200 (31.46 and 26.08).\n\nPrescribed Dirichlet values are imposed explicitly and residuals are evaluated only on interior nodes; the flow benchmarks use periodic operators. These targeted checks corroborate the original PDE-Error evaluation: the few-step gains are not confined to the training stencil and are supported by independent solution, balance, boundary, and spectral diagnostics.\n\n\n## 2. Are the evaluated resolutions restricted to $32^2$? (W2)\n\n**No; the higher-resolution evidence was already included but insufficiently visible.** Unconditional Navier–Stokes uses a $64^2$ spatial grid; Burgers uses a $128\\times128$ space–time grid; and Helmholtz and the main conditional Darcy/Helmholtz tasks use $128^2$ spatial grids.\n\nAppendix F.2 further evaluates Poisson at $128^2$, $256^2$, and $512^2$ against the corresponding multi-step EDM teacher, providing a matched generative-baseline comparison at every resolution. The student/teacher PDE-Error ratios are 41%, 59%, and 34%, respectively. At $512^2$, one-step inference requires 317 ms and approximately 3.1 GB on one A100. We will make these results more prominent in the revision."
+ },
+ "createdAt": "2026-07-29T18:17:56.008Z",
+ "modifiedAt": "2026-11-19T16:59:30.263Z",
+ "url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=nDCKc8Yy6v",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xqgamz3x8f/notes/nkjbpjcc8q.json added

+++ b/reviews/openreview/xqgamz3x8f/notes/nkjbpjcc8q.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "NkJbPjcc8q",
+ "replyTo": "pimSylYKPL",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer nE2R",
+ "content": {
+ "comment": "Thank you for the detailed rebuttal. The responses address most of my concerns and provide substantial additional experimental evidence. In particular, I appreciate the clarifications on the computation of PDE Error, the added independent physical evaluations, the higher-resolution results, the uncertainty and diversity analyses, and the clarification of the baseline protocols and model capacities. These additions strengthen the empirical evaluation and improve the presentation of the paper. I will take these responses into account when updating my final assessment after the discussion period."
+ },
+ "createdAt": "2026-07-30T13:34:28.919Z",
+ "modifiedAt": "2026-11-19T16:59:30.430Z",
+ "url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=NkJbPjcc8q",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xqgamz3x8f/notes/pxsnfc70lm.json added

+++ b/reviews/openreview/xqgamz3x8f/notes/pxsnfc70lm.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "pXSNFC70lM",
+ "replyTo": "mTNmf0vDEN",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Reviewer obxi [2/3]",
+ "comment": "# Response to Reviewer obxi [2/3]\n\n## 4. How does the student behave beyond 4 sampling steps? (Q4)\n\n**Phys-Instruct can benefit from more than four steps, provided that the larger budget is included during training.** A student trained only up to $K=4$ cannot simply be run for 8 steps because its transport schedule was not trained for an eight-stage mapping. We therefore additionally train an unconditional Burgers student with maximum budget $K=8$.\n\nSWD measures discrepancy from held-out Burgers data, recall measures support coverage, and Diversity/T200 measures sample variation relative to EDM-200, where 1 denotes teacher-level diversity.\n\n| $k$ | sec/sample | PDE Error $\\downarrow$ | SWD $\\downarrow$ | Recall $\\uparrow$ | Diversity/T200 $(\\to1)$ |\n|---:|---:|---:|---:|---:|---:|\n| 1 | 0.012 | 0.171 | 0.071 | 0.674 | 0.658 |\n| 2 | 0.036 | 0.118 | 0.060 | 0.830 | 0.896 |\n| 4 | 0.084 | 0.055 | 0.049 | 0.930 | 0.890 |\n| 8 | 0.225 | 0.046 | 0.046 | 0.919 | 0.905 |\n\nMost gains occur from 1 to 4 steps. Increasing from 4 to 8 step further reduces PDE Error from 0.055 to 0.046 and SWD from 0.049 to 0.046, while diversity increases from 0.890 to 0.905; recall remains similar, with a small decrease from 0.930 to 0.919. Thus, 8-step sampling remains effective when explicitly trained, but provides smaller additional gains at higher latency.\n\n## 5. Why are Flow Matching and transformer backbones not included, and what does Phys-Instruct offer beyond deterministic PDE solvers? (Q3, Q5)\n\n**Flow Matching and transformer backbones change different components of the implementation and are not the contribution being isolated here.** Flow Matching changes the generative teacher formulation, while a transformer changes the network backbone. We keep the EDM teacher and SongUNet backbone fixed throughout the controlled study. \n\nAt the framework level, Phys-Instruct is not restricted to either choice. With a pretrained Flow-Matching teacher, the score-based distribution-alignment component can be replaced by its flow/velocity counterpart while retaining sample-level physics guidance. Likewise, the framework does not rely on SongUNet-specific operations and can use a transformer backbone. **Our goal is not to identify the strongest generative PDE architecture, but to show that a given pretrained generative PDE model can be converted into a much faster one-/few-step sampler while improving PDE Error.** A controlled comparison would require training a matched Flow-Matching teacher and the corresponding physics-guided student; otherwise the teacher formulation and distillation objective would change simultaneously. \n\nThe distinction from the deterministic baselines in Table 11 is more fundamental than inference speed. Deterministic solvers in Table 11 learn task-specific mappings to point predictions. Phys-Instruct instead starts from a generative joint prior over PDE inputs and solutions. After distillation, the prior supports unconditional generation and can be adapted to forward, inverse, and partial-observation tasks while retaining a distribution over possible solutions.\n\nThis probabilistic capability is demonstrated by an additional Poisson-forward UQ experiment under 5% partial observations. We evaluate 10 held-out cases, draw 50 conditional samples per case, and score only unobserved locations. The one-step model achieves CRPS 0.0066 and 89.08% empirical coverage for a nominal 90% interval. Table 11 further shows that this generative setup remains accurate on point-prediction tasks. Thus, the broader contribution is a reusable probabilistic PDE prior; fast inference is an important benefit, but not the only distinction from deterministic solvers.\n\n## 6. What is the difference from Luo et al./Diff-Instruct, and which table gives the controlled comparison? (Q6; W2)\n\n**Diff-Instruct provides the IKL distribution-matching foundation; Phys-Instruct integrates sample-level PDE guidance into this objective and supports flexible $k$-step unrolling.** The resulting student amortizes physics correction into its parameters and requires no PDE guidance at inference.\n\nEqs. (9)-(10) show this integration explicitly. The most direct controlled comparison is the same-architecture **w/o Guidance** ablation in Table 2: removing physics guidance increases one-step Darcy PDE Error from 0.315 to 8.75. Appendix Table 7 is instead the resolution-scaling experiment. We will make both the methodological distinction and the correct table reference explicit."
+ },
+ "createdAt": "2026-07-29T17:51:51.071Z",
+ "modifiedAt": "2026-11-19T16:59:30.470Z",
+ "url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=pXSNFC70lM",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xqgamz3x8f/notes/qjg5xv3tss.json added

+++ b/reviews/openreview/xqgamz3x8f/notes/qjg5xv3tss.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "qjG5XV3TsS",
+ "replyTo": "uydpjaogvy",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Reviewer KTwv [2/4]",
+ "comment": "# Response to Reviewer KTwv [2/4]\n\n## 3. Can Phys-Instruct handle a complex temporal PDE, and what did the original Navier–Stokes test establish? (W2, W3; Q2)\n\n**The original Navier–Stokes benchmark uses only terminal snapshots, whereas the new Kolmogorov experiment evaluates the complete time-dependent vorticity equation locally in time.**\n\nThe original Navier–Stokes data contain only $(\\omega_0,\\omega_T)$, so its terminal surrogate does not evaluate temporal evolution or establish full forward/inverse capability. Burgers includes temporal dynamics, but only in one spatial dimension.\n\nWe added the reviewer-suggested 2D $Re=1000$ Kolmogorov benchmark. Each trajectory is converted into overlapping three-frame $256\\times256$ samples. Because no pretrained three-frame model was available, we train an EDM teacher and distill it into an 8-step Phys-Instruct student. Burgers provides the systematic $k$-analysis; here $k=8$ is a representative few-step setting.\n\nAt the middle frame, we estimate the temporal derivative from the adjacent frames and evaluate the advection, viscous, forcing, and damping terms pseudo-spectrally. **PDE Error** is the RMS equation residual used for physics guidance. **Spectral PDE Error** recomputes the residual with an independent dealiased evaluator. **Spectrum mismatch** measures the radial-spectrum gap to EDM-200. These are local-in-time diagnostics, not long-horizon rollout tests.\n\n| Method | Steps | PDE Error $\\downarrow$ | Spectral PDE Error $\\downarrow$ | Spectrum mismatch $\\downarrow$ |\n|---|---:|---:|---:|---:|\n| EDM sampling | 8 | 150.2 | 106.13 | 1.880 |\n| Phys-Instruct (ours) | 8 | **18.86** | **17.09** | **0.291** |\n| EDM sampling | 200 | 31.46 | 26.08 | 0 (reference) |\n\nPhys-Instruct-8 achieves lower PDE Error and Spectral PDE Error than EDM-200 (18.86/17.09 versus 31.46/26.08). Its spectrum mismatch is also substantially smaller than that of EDM-8 (0.291 versus 1.880). This supports few-step applicability to complex temporal flow.\n\n\n## 4. Physical consistency beyond mean PDE residual (PDE Error) (W6; Q1)\n\n\n**The additional checks show that the few-step gains persist under held-out discretizations, independent re-solving or re-integration, conservation and balance metrics, spectral residuals, and spectrum structure.**\n\nFor unconditional Poisson generation, we independently re-solve every generated forcing and compare the generated solution and gradients with the numerical solution. We also evaluate a held-out fourth-order residual not used during training.\n\n| Method | Steps | Held-out FD4 $\\downarrow$ | Re-solve $L^2$ $\\downarrow$ | Re-solve $H^1$ $\\downarrow$ |\n|---|---:|---:|---:|---:|\n| Phys-Instruct (ours) | 1 | 0.0276 | 0.0268 | 0.0366 |\n| -- | 4 | **0.00576** | **0.00674** | **0.00649** |\n| EDM | 200 | 0.0423 | 0.0125 | 0.0151 |\n\nThe 1-step Phys-Instruct lowers the held-out residual before the independent solution errors are fully recovered. At 4 steps, however, Phys-Instruct improves the held-out residual together with both re-solve errors. This shows that the few-step gain persists under a different discretization and extends to independently evaluated solution values and gradients.\n\nFor Burgers, we additionally evaluate an independent spectral residual, mass conservation, viscous energy balance:\n\n| Method | Steps | Spectral residual $\\downarrow$ | Mass defect $\\downarrow$ | Energy-balance defect $\\downarrow$ |\n|---|---:|---:|---:|---:|\n| Phys-Instruct (ours) | 1 | **1.136** | 0.0354 | 0.1968 |\n| -- | 4 | 1.194 | **0.0119** | **0.1016** |\n| EDM | 200 | 1.630 | 0.0134 | 0.2969 |\n\n\nPhys-Instruct-4 closely matches EDM-200 in rollout accuracy (0.0300 versus 0.0309) while achieving lower spectral residual, mass defect, and energy-balance defect. \n\nFor Kolmogorov, the held-out residual RMS/P95/P99/maximum are 17.09/25.60/61.61/406.30, compared with 106.13/181.08/383.63/2233.96 for EDM-8 and 26.08/41.69/99.73/549.80 for EDM-200. The gain is therefore not limited to the mean residual.\n\nBoundary conditions are all satisfied by construction in the corresponding discretizations. Prescribed Dirichlet values are imposed explicitly and residuals are evaluated only on interior nodes; the flow benchmarks use periodic operators. \n\nThese results show that lower PDE Errors are accompanied by improved gradient accuracy and preserved spectral structure, providing no evidence of severe over-smoothing."
+ },
+ "createdAt": "2026-07-29T18:08:05.720Z",
+ "modifiedAt": "2026-11-19T16:59:30.568Z",
+ "url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=qjG5XV3TsS",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xqgamz3x8f/notes/qv4xbw9nfp.json added

+++ b/reviews/openreview/xqgamz3x8f/notes/qv4xbw9nfp.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "qV4XBw9nfp",
+ "replyTo": "xsMRtXiNf3",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer obxi",
+ "content": {
+ "comment": "I thank again the authors for their responses to my follow-up questions. \n\nQ2 / Thanks for the precisions. On this point, I would have a last question. Since the weightning of the losses is important for the convergence of the method (and could even lead to a failure of the training), would you have any insights/recommandations for the reader on how one should balance the two terms ? \n\nAs a conclusion, my opinion on the paper toward acceptance still holds and my concerns have been adressed. With the suggested modifications during the rebuttal by all the reviewers, the paper shows interesting conclusion and a thorough evaluation. It could be the basis for future extensions. All these elements will be used for the upcoming reviewer-AC discussion. Thanks again!"
+ },
+ "createdAt": "2026-08-03T11:52:09.748Z",
+ "modifiedAt": "2026-11-19T16:59:30.287Z",
+ "url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=qV4XBw9nfp",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xqgamz3x8f/notes/sici5slsrt.json added

+++ b/reviews/openreview/xqgamz3x8f/notes/sici5slsrt.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "SIcI5SLSrT",
+ "replyTo": "qV4XBw9nfp",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer,\n\nThank you very much for your positive assessment and for this useful final question. Appendix G.1 provides a practical tuning guideline, which we summarize here for clarity.\n\nMechanistically, IKL serves as the distributional anchor, while the residual provides the per-sample physical correction. The goal is therefore to make the correction strong enough to improve equation consistency without overwhelming distribution alignment.\n\nIn practice, we initialize $\\lambda_{\\mathrm{phys}}=1e^{-3}$ and run a short early-training stage, typically requiring less than 15 minutes in our experiments. As a practical proxy for balancing the generator update, we compare the magnitudes of the IKL term and the weighted physics term, $\\lambda_{\\mathrm{phys}}\\mathcal{L}_{\\mathrm{phys}}$, aiming to keep them within the same order of magnitude while monitoring PDE Error and training stability.\n\nIf the weighted physics term is substantially smaller and PDE Error shows little improvement, we increase $\\lambda_{\\mathrm{phys}}$ by a factor of 10. If it is substantially larger than the IKL term, or training becomes unstable, we decrease it by the same factor. Once the appropriate order of magnitude is identified, it is generally sufficient; further local adjustment is optional.\n\nWe will make this guideline more prominent in the revised manuscript. Thank you again for the constructive discussion and positive assessment."
+ },
+ "createdAt": "2026-08-03T19:42:28.709Z",
+ "modifiedAt": "2026-11-19T16:59:30.040Z",
+ "url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=SIcI5SLSrT",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xqgamz3x8f/notes/uqspo11boe.json added

+++ b/reviews/openreview/xqgamz3x8f/notes/uqspo11boe.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "uQsPO11BoE",
+ "replyTo": "DgMqgcGsBw",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "## Mechanistic insight: why residual guidance works and when it fails\n\nDear Reviewer,\n\nThank you for the positive assessment and for acknowledging that the rebuttal resolves many empirical concerns. We interpret your remaining point as requesting a mechanism-level explanation of when residual-based physics guidance is effective and when it breaks down.\n\nPhys-Instruct reveals an interaction among three factors: teacher-distribution alignment, per-sample physics guidance, and few-step transport capacity.\n\n**Why it works.** IKL aligns the student-induced noisy-time marginals with those of the pretrained teacher, providing a distributional anchor that encourages preservation of the learned joint structure and variability of PDE inputs and solutions. Within this anchor, the physics term supplies a sample-wise correction direction: for each generated clean pair $x_0=g_\\theta(z;k)$, the second component of Eq. (10) updates the generator locally toward lower $R(x_0)$. Thus, IKL constrains **where generated probability mass should remain**, while the residual supplies **the local direction by which each realization is physically corrected within that region**.\n\nThis coupling is essential. IKL alone transfers the teacher distribution but does not preferentially correct equation violations retained by the teacher or introduced by aggressive compression. The residual supplies that preference, while IKL discourages the student from pursuing low residual at the expense of the learned PDE distribution. Phys-Instruct therefore turns few-step distillation from pure distribution transfer into **teacher-aligned, physics-directed distribution shaping**.\n\nTwo properties make this mechanism effective. First, the correction is **per-sample**: Eq. (8) evaluates PDE error on each generated final realization before taking the expectation, rather than on a mean prediction. For nonlinear PDEs, averaging and residual evaluation do not commute, so a low-residual mean can conceal violations in individual samples. Second, the correction is **amortized**: Eq. (10) and Remark 4.2 show that the residual-reducing direction is learned into the student. The distilled unconditional generator therefore requires neither iterative physics guidance nor a PDE evaluator at inference. This distribution-level alignment, rather than sample-wise imitation, also allows physics to shift probability mass toward more equation-consistent regions and thereby improve PDE Error beyond the teacher.\n\n**When it fails.** The same mechanism explains three failure conditions:\n\n1. **Gradient imbalance.** If the physics weight is too small, the correction is negligible. If it is too large, it overwhelms distribution alignment and destabilizes training, leading to mode collapse or divergence, as observed in the Darcy ablation. Guidance is effective in the intermediate regime where physics corrects samples without dominating IKL.\n\n2. **Residual–accuracy mismatch.** A discrete residual can be an informative local training signal without being a complete certificate of solution accuracy. For Poisson at $k=1$, the held-out residual improves over EDM-200, but independent re-solve $L^2/H^1$ errors remain worse; at $k=4$, both improve. Guidance may therefore reduce the optimized equation metric without commensurate solution-accuracy gains when the residual is insufficiently informative.\n\n3. **Insufficient transport capacity.** Under extreme one-step compression, the student must preserve the teacher distribution and incorporate the physical correction through a highly constrained transport. Increasing the step budget recovers most of the support and diversity gap while further reducing PDE Error, consistent with additional capacity making the objectives easier to reconcile.\n\nThese observations yield a unified criterion: Phys-Instruct is most effective when the teacher provides a reliable distributional anchor, the per-sample residual provides an informative and properly scaled correction, and the student has sufficient transport capacity. Its failure modes arise when one of these conditions is violated.\n\nThe central conceptual contribution is a constrained distribution-matching formulation that derives complementary distribution-level and per-sample updates and amortizes physical correction into a reusable one-/few-step generator. This formulation explains both the substantial speed–consistency gains and the observed boundaries of the method. We will make this unifying interpretation more explicit in the revised manuscript.\n\nWe hope this directly addresses the insight you had in mind. Given your assessment that many empirical concerns have been resolved, we would appreciate it if you could take this clarification into account when reconsidering your final assessment.\n\nThank you again for the thoughtful and constructive feedback."
+ },
+ "createdAt": "2026-08-02T16:44:35.391Z",
+ "modifiedAt": "2026-11-19T16:59:30.126Z",
+ "url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=uQsPO11BoE",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xqgamz3x8f/notes/xbrsh9nqr0.json added

+++ b/reviews/openreview/xqgamz3x8f/notes/xbrsh9nqr0.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "XbRsH9nQR0",
+ "replyTo": "mTNmf0vDEN",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Reviewer obxi [3/3]",
+ "comment": "# Response to Reviewer obxi [3/3]\n\n## 7. What is the training cost relative to the baselines? (Q7)\n\n**Phys-Instruct incurs a one-time distillation overhead; we do not claim lower training cost.** The teacher (EDM), student, and training-only auxiliary use the same SongUNet architecture, with 54.41M parameters each.\n\nDiffusionPDE and CoCoGen use the same pretrained EDM model but add no distillation stage (they conduct PDE correction steps during inference); PIDM is trained in a separate single stage. We therefore report the shared EDM pretraining cost, PIDM training cost, the additional Phys-Instruct distillation cost, and the Phys-Instruct total.\n\n| Benchmark | EDM | PIDM | Phys distillation | Phys total |\n|---|---:|---:|---:|---:|\n| Darcy | 689.4 | 1047.3 | 506.9 | 1196.3 |\n| Poisson | 689.4 | 1047.3 | 506.9 | 1196.3 |\n| Navier–Stokes | 1609.0 | 2352.4 | 1191.1 | 2800.1 |\n\nAll values are training compute in kTFLOPs. Distillation costs approximately 74% of EDM pretraining. Including teacher pretraining, Phys-Instruct costs about 14% more than PIDM on Darcy and Poisson and about 19% more on Navier–Stokes.\n\nFor Burgers and Helmholtz, the pretrained EDM checkpoints were inherited, so only the measured distillation costs are available: 3185.3 and 3364.9 kTFLOPs, respectively, compared with PIDM costs of 7406.2 and 7921.6 kTFLOPs. Because the original EDM pretraining costs are unavailable, we do not report incomplete end-to-end Phys-Instruct totals for these two tasks.\n\nThe intended trade-off is additional one-time training for repeated one-/few-step inference without test-time PDE correction, while retaining a generative prior that can be reused across unconditional and downstream conditional tasks.\n\n## 8. What is the practical purpose of unconditional generation, how should “high fidelity” be read, why does Darcy use a different metric, and what limitations will be added? (Q8; W3, M2, L1)\n\nThe PDE inputs are generated explicitly as output channels together with the solutions, so they do not need to be reconstructed from the generated solution.\n\n**Practical role of unconditional generation.** The model jointly generates PDE inputs and solutions, for example, $(f,u)$ for Poisson or $(a,u)$ for Darcy. The generated pairs can be used as synthetic PDE data. Boundary conditions are fixed by each benchmark definition: prescribed Dirichlet values are imposed explicitly, while the flow benchmarks use periodic boundaries. The independent Poisson re-solve check supports the forward numerical consistency of these generated pairs: Phys-Instruct-4 achieves re-solve $L^2/H^1$ errors of $6.742\\times10^{-3}/6.487\\times10^{-3}$. Separately, the learned joint prior can be adapted to downstream forward and inverse tasks.\n\n**High-fidelity terminology. (W3)** We agree that “high fidelity” can be interpreted as super-resolution or recovery of unresolved fine-scale details. This is not our intended claim. We use the term to describe accurate generation with improved equation consistency at the evaluated resolution. The paper includes resolution-scaling experiments up to $512^2$, but we do not claim super-resolution; we will revise the wording accordingly.\n\n**Darcy metric. (M2)** Darcy inverse predicts a binary permeability field, so Table 3 uses an absolute/classification-style error for this discrete output; continuous fields use relative $L^2$ error.\n\n**Limitations.** We will add a dedicated paragraph stating that aggressive compression can contract the unconditional distribution; the present formulation is fixed-grid and uses task-specific PDE evaluators; general operator-parameter conditioning is not evaluated; and calibrated conditional uncertainty is not theoretically guaranteed.\n\n## Conclusion\n\nWe will revise Figure 2, clarify the scope of PDE Error and “high fidelity,” and add the stated limitations. The additional analyses further support Phys-Instruct as a reusable few-step generative PDE prior that incorporates physics during training without requiring inference-time correction."
+ },
+ "createdAt": "2026-07-29T17:06:43.758Z",
+ "modifiedAt": "2026-11-19T16:59:30.578Z",
+ "url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=XbRsH9nQR0",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xqgamz3x8f/notes/xsmrtxinf3.json added

+++ b/reviews/openreview/xqgamz3x8f/notes/xsmrtxinf3.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "xsMRtXiNf3",
+ "replyTo": "XbRsH9nQR0",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Followup [2/2]",
+ "comment": "# Response to Followup [2/2]\n\n## 4/Q4: Is the model overfitted to the allowed number of steps?\n\nWe would describe this as specialization to a trained few-step transport, rather than overfitting.\n\nThe step setting differs from that of the diffusion teacher. For the teacher, the number of sampling steps is a numerical discretization choice that can be changed at inference. Phys-Instruct instead learns the few-step transport during distillation. In the main setting, one student is jointly trained over $k \\in \\{1,2,3,4\\}$, so it supports multiple step counts and is not fitted to a single value of $k$.\n\nNor is the student fitted to a particular teacher sampling trajectory. As shown in Eq. (10), the IKL objective aligns the student- and teacher-induced marginal distributions over the full noise-time interval $t\\in[0,T]$, rather than regressing to one discrete teacher path.\n\nFor a fixed student, simply adding iterations beyond the trained setting is unsupported, so there is no expected pattern of convergence or stabilization in that regime. To examine a larger valid budget, we additionally trained an eight-step Burgers setting. Compared with the four-step result, it modestly improves PDE Error, SWD, and diversity, while Recall remains similar.\n\nThus, the results indicate diminishing returns as the explicitly trained step budget increases, rather than overfitting to a particular step count or teacher trajectory.\n\n\n## 5/Q3: Why use a diffusion teacher rather than Flow Matching?\n\nWe agree that Flow Matching is an important direction. We chose diffusion because Phys-Instruct targets a practical post-training problem: converting already trained and validated diffusion PDE models into physics-guided one-/few-step models.\n\nFor this benchmark suite, the established teachers and training recipes, released checkpoints where available, and closest physics-guided baselines were diffusion-based. Keeping this family fixed allowed us to isolate physics-guided distillation while controlling the teacher, backbone, data, and evaluation setting. Using Flow Matching would first require training and validating matched teachers and would define a separate teacher-family study.\n\nWe do not claim that diffusion is intrinsically preferable or that Phys-Instruct is incompatible with Flow Matching. A matched Flow-Matching teacher could follow the same principle, but a reliable one-/few-step student would still require an appropriate low-step distillation or flow-map formulation. We therefore restrict the present empirical scope to pretrained diffusion models and view Flow Matching as a natural complementary extension.\n\n## 5/Q5: How should Table 11 be interpreted?\n\nAs the reviewer notes, deterministic solvers are not the main focus of this work. Table 11 was included to assess if the adapted generative prior remains competitive on the same forward and inverse PDE tasks, rather than to claim superiority over the SOTA deterministic models.\n\nTo make the comparison more representative, in the final version we will include recent deterministic operator-learning methods with official implementations, for example, Transolver++ [1] for matched forward tasks, together with recent inverse-capable operators where the same input/output setting can be reproduced. All comparisons will use the same data, splits, resolutions, and metrics, and we will state the scope of Table 11 explicitly.\n\n\nThank you again for the constructive discussion. We would be glad to address any further questions or provide additional clarification during the remainder of the discussion period.\n\n**References**\n\n[1] H. Luo et al., “Transolver++: An Accurate Neural Solver for PDEs on Million-Scale Geometries,” 2025."
+ },
+ "createdAt": "2026-08-01T17:30:35.971Z",
+ "modifiedAt": "2026-11-19T16:59:30.276Z",
+ "url": "https://openreview.net/forum?id=XQGamZ3x8F&noteId=xsMRtXiNf3",
+ "license": "CC-BY-4.0"
+}