HALMES: Knowing When to Intervene in LVLM Hallucination Mitigation
Update NeurIPS 2026 submission O8ShETkdl7: 15 notes
@openreview[bot] · 2026-11-24 15:50 UTC · 0c5dfc99ff0f ·
reviews/openreview/o8shetkdl7/notes/1cpfmcpnng.json added
+++ b/reviews/openreview/o8shetkdl7/notes/1cpfmcpnng.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "1CPFMcPNng",+ "replyTo": "nZwjbg9jA8",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Additional Clarifications for Reviewer NbG5 (Part 2 / 3)",+ "comment": "### **Q4: Training sample statistics, data scaling, and HALMES training and evaluation on non-COCO splits**\n\nThe exact numbers of positive and negative token-segment training samples are reported below.\n\n| LVLM | Positive segments | Negative segments |\n|---|---:|---:|\n| **Qwen3VL-8B** | 1,499 | 4,486 |\n| **InternVL3.5-8B** | 1,643 | 4,925 |\n\nAs the rebuttal platform does not allow image uploads, we cannot present the learning curves as figures. We therefore report detector performance at increasing training-set sizes in tabular form, using InternVL3.5-8B as a representative example:\n\n| Training data | AUROC ↑ | Accuracy ↑ | Recall ↑ | PR-AUC ↑ | FPR ↓ |\n|---|---:|---:|---:|---:|---:|\n| **20%** | 86.04 | 76.79 | 70.24 | 85.13 | 16.67 |\n| **40%** | 86.92 | 78.87 | 78.57 | 85.67 | 20.83 |\n| **60%** | 87.28 | 80.21 | 84.82 | 86.70 | 24.40 |\n| **80%** | 88.93 | 82.14 | 85.42 | 87.91 | 21.13 |\n| **100%** | 90.52 | 83.63 | 87.20 | 90.03 | 19.94 |\n\nTo evaluate HALMES under a fully non-COCO training/test setting, we construct disjoint training and test splits from the 1,000-image generative subset of AMBER, and train HALMES entirely on the AMBER training split using Qwen3VL-8B as the backbone. The resulting performance on the held-out AMBER test split is:\n\n| AUROC ↑ | Accuracy ↑ | Recall ↑ | PR-AUC ↑ | FPR ↓ |\n|---:|---:|---:|---:|---:|\n| 87.77 | 85.63 | 82.50 | 88.05 | 11.25 |\n\nWe then evaluate hallucination mitigation on COCO subset using the detector trained on AMBER:\n\n| Backbone | CD method | $\\Delta$CHAIR-i ↑ | $\\Delta$CHAIR-s ↑ | $\\Delta$Coverage ↑ |\n|---|---|---:|---:|---:|\n| Qwen3VL-8B | VCD | +0.20 | +1.85 | +1.33 |\n| Qwen3VL-8B | M3ID | +4.55 | +9.53 | −1.97 |\n| Qwen3VL-8B | AVISC | +0.12 | +0.21 | −2.75 |\n| Qwen3VL-8B | SID | +1.24 | +1.60 | −0.31 |\n| Qwen3VL-8B | Self-Aug | +1.12 | +6.66 | +0.12 |\n| **Qwen3VL-8B** | **Average** | **+1.45** | **+3.97** | **−0.72** |\n\nThese results show that HALMES can be trained and applied on a non-COCO dataset while maintaining effective hallucination detection and mitigation across different CD methods."+ },+ "createdAt": "2026-07-31T16:43:18.389Z",+ "modifiedAt": "2026-11-19T17:05:19.115Z",+ "url": "https://openreview.net/forum?id=O8ShETkdl7¬eId=1CPFMcPNng",+ "license": "CC-BY-4.0"+}
reviews/openreview/o8shetkdl7/notes/1jpx1rtl7a.json added
+++ b/reviews/openreview/o8shetkdl7/notes/1jpx1rtl7a.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "1jpx1RTL7A",+ "replyTo": "5yFglzdSB7",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer NbG5",+ "comment": "**Additional Robustness Results Across Random Seeds and Disjoint Evaluation Subsets**\n\n### 1. Stability across random seeds\n\nGiven the limited rebuttal period, we conducted this analysis on a fixed 100-image subset of the COCO evaluation set used in our main experiments and reran all ten backbone–CD combinations under three different decoding seeds. For each run, HALMES and the corresponding full-stage CD method used the same decoding seed. We report the mean and standard deviation across the three runs.\n\n> **Table 1: Mean improvements and standard deviations across three decoding seeds on a fixed 100-image COCO subset.**\n\n| Backbone | CD Method | $\\Delta$CHAIR$_i$ $\\uparrow$ | $\\Delta$CHAIR$_s$ $\\uparrow$ | $\\Delta$Coverage $\\uparrow$ |\n|---|---|---:|---:|---:|\n| InternVL3.5-8B | VCD | $+2.18 \\pm 0.75$ | $+2.00 \\pm 0.73$ | $+0.64 \\pm 1.80$ |\n| InternVL3.5-8B | M3ID | $+1.46 \\pm 0.65$ | $+3.00 \\pm 1.00$ | $+0.38 \\pm 0.76$ |\n| InternVL3.5-8B | AVISC | $+1.27 \\pm 0.55$ | $+5.00 \\pm 1.54$ | $+0.76 \\pm 0.66$ |\n| InternVL3.5-8B | SID | $+1.24 \\pm 0.48$ | $+3.67 \\pm 1.08$ | $-1.27 \\pm 0.88$ |\n| InternVL3.5-8B | Self-Aug | $+0.28 \\pm 0.26$ | $+2.67 \\pm 0.58$ | $-1.07 \\pm 0.58$ |\n| Qwen3VL-8B | VCD | $+1.13 \\pm 0.44$ | $+2.67 \\pm 0.83$ | $+0.38 \\pm 2.13$ |\n| Qwen3VL-8B | M3ID | $+2.86 \\pm 0.69$ | $+6.67 \\pm 2.08$ | $+1.40 \\pm 0.88$ |\n| Qwen3VL-8B | AVISC | $+2.19 \\pm 0.59$ | $+5.33 \\pm 2.52$ | $-1.56 \\pm 0.79$ |\n| Qwen3VL-8B | SID | $+0.22 \\pm 0.14$ | $+4.67 \\pm 2.52$ | $-0.42 \\pm 1.23$ |\n| Qwen3VL-8B | Self-Aug | $+0.92 \\pm 0.35$ | $+0.67 \\pm 0.43$ | $+1.27 \\pm 1.45$ |\n\nThe three-seed averages favor HALMES on both hallucination metrics in all ten backbone–method combinations. Moreover, the mean improvement exceeds the corresponding standard deviation in every combination, indicating that the observed gains are larger than the typical seed-induced variation. Across all combinations, HALMES improves CHAIR$_i$ and CHAIR$_s$ by **1.38 pp** and **3.64 pp**, with average standard deviations of **0.49 pp** and **1.33 pp**, respectively, while Coverage remains nearly unchanged (**+0.05 pp**). These results support consistent positive gains across decoding seeds without a systematic change in Coverage.\n\n### 2. Stability across independently sampled evaluation subsets\n\nTo examine sensitivity to sample selection, we additionally evaluated HALMES on a non-overlapping 100-image subset from COCO val2014 and a non-overlapping 500-sample subset from AMBER. Neither subset overlaps with the samples used in our main evaluation.\n\n> **Table 2: Results on an independently sampled 100-image COCO subset.**\n\n| Backbone | CD Method | $\\Delta$CHAIR$_i$ $\\uparrow$ | $\\Delta$CHAIR$_s$ $\\uparrow$ | $\\Delta$Coverage $\\uparrow$ |\n|---|---|---:|---:|---:|\n| InternVL3.5-8B | VCD | +2.02 | +2.00 | +2.67 |\n| InternVL3.5-8B | M3ID | +0.38 | +2.00 | +0.76 |\n| InternVL3.5-8B | AVISC | +2.53 | +8.00 | −3.05 |\n| InternVL3.5-8B | SID | +2.97 | +5.00 | +0.38 |\n| InternVL3.5-8B | Self-Aug | +0.87 | +5.00 | −0.76 |\n| Qwen3VL-8B | VCD | +4.00 | +7.00 | +1.53 |\n| Qwen3VL-8B | M3ID | +3.20 | +9.00 | +2.29 |\n| Qwen3VL-8B | AVISC | +0.53 | +1.00 | +1.91 |\n| Qwen3VL-8B | SID | +1.90 | +6.00 | +0.76 |\n| Qwen3VL-8B | Self-Aug | +0.33 | +3.00 | +0.76 |\n\nOn the disjoint COCO subset, HALMES improves both CHAIR metrics in all **10/10** backbone–method combinations and Coverage in **8/10** combinations. The average improvements are **1.87 pp** in CHAIR$_i$, **4.80 pp** in CHAIR$_s$, and **0.73 pp** in Coverage, reproducing the overall trend of the main results.\n\n> **Table 3: Results on an independently sampled 500-example AMBER subset.**\n\n| Backbone | CD Method | $\\Delta$CHAIR $\\uparrow$ | $\\Delta$Cover $\\uparrow$ | $\\Delta$Cog $\\uparrow$ | $\\Delta$Hal $\\uparrow$ |\n|---|---|---:|---:|---:|---:|\n| InternVL3.5-8B | VCD | +0.48 | −1.21 | −0.17 | +3.80 |\n| InternVL3.5-8B | M3ID | +0.65 | −0.98 | +0.20 | +4.00 |\n| InternVL3.5-8B | AVISC | +1.39 | +1.05 | +0.12 | +1.80 |\n| InternVL3.5-8B | SID | +0.95 | −2.52 | −0.12 | +2.80 |\n| InternVL3.5-8B | Self-Aug | +0.27 | +1.27 | +0.19 | +3.20 |\n| Qwen3VL-8B | VCD | +0.67 | +0.73 | −0.34 | −1.80 |\n| Qwen3VL-8B | M3ID | +0.54 | −0.05 | −0.22 | +4.40 |\n| Qwen3VL-8B | AVISC | +0.12 | 0.00 | −0.04 | +0.40 |\n| Qwen3VL-8B | SID | −0.36 | −1.01 | +0.32 | −0.60 |\n| Qwen3VL-8B | Self-Aug | +0.24 | +0.23 | +0.02 | −0.80 |\n\nOn the disjoint AMBER subset, HALMES improves CHAIR in **9/10** combinations and Hal in **7/10** combinations, with average gains of **0.50 pp** and **1.72 pp**, respectively. Coverage shows a pattern similar to the main results, with modest decreases for some CD methods.\n\n---\n\nOverall, these results show that HALMES delivers consistent hallucination-reduction gains across decoding seeds and remains effective across independently sampled evaluation subsets. We hope these additional experiments have effectively addressed your concern."+ },+ "createdAt": "2026-07-28T16:45:44.088Z",+ "modifiedAt": "2026-11-19T17:05:19.238Z",+ "url": "https://openreview.net/forum?id=O8ShETkdl7¬eId=1jpx1RTL7A",+ "license": "CC-BY-4.0"+}
reviews/openreview/o8shetkdl7/notes/6bj99srooa.json added
+++ b/reviews/openreview/o8shetkdl7/notes/6bj99srooa.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "6bj99sRooa",+ "replyTo": "5yFglzdSB7",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer NbG5",+ "content": {+ "comment": "Thank you for the detailed rebuttal. I still have several points that need clarification.\n\n1. *\"We will provide a clearer explanation of this distinction in the possible camera-ready version.\"* This does not fully address my concern. I asked for the **exact construction of (I') and (x')**. The authors admit that HALMES does not design a new contrastive branch, but they still do not specify how the contrastive branch is constructed for each baseline. The unified Eq. (2) is also somewhat misleading because not every method simply uses a distorted (I') or (x'). For example, M3ID contrasts image-conditioned and language-prior predictions, AVISC uses blind-token-biased logits, and SID modifies internal visual-token processing.\n\n2. In Lines 561-563, the paper states that *\"K is mainly determined according to the length distribution of token segments in the training data.\"* However, in the rebuttal, the authors mention using a fixed value of **(K=15)**. Could the authors please clarify this? Is (K=15) used for all experiments, or is it selected differently for different settings?\n\n3. In Lines 77-78 and Lines 311-312, the paper describes HALMES as providing *\"on-demand correction.\"* While the correction itself is applied on demand, the rebuttal clarifies that **both branches are still computed throughout generation**. Please report the exact values of $(\\theta_{\\text{high}}), (\\theta_{\\text{low}})$, and the warm-up/cool-down counter limits for each LVLM. Also, please clarify what *\"trend-aware\"* means, since Algorithm 1 does not appear to impose an explicit positive-trend condition.\n\n4. The detector is trained using only 5,000 COCO images with CHAIR-derived object-noun labels. I appreciate that the authors additionally evaluated HALMES on multiple datasets to demonstrate some level of generalization. However, could the authors report the exact number of positive and negative token-segment training samples, provide learning curves as the training-set size increases, and, if possible, include results on non-COCO or category-disjoint training/test splits? In addition, could the authors explain how HALMES could be useful beyond image captioning or hallucination-specific benchmarks, for example on video understanding (LVBench, VideoMME, LongVideoBench), coding (MBPP, HumanEval), mathematics (GSM8K, MATH500, MathVista, VideoMath), or medical benchmarks (PathVQA, PMC-VQA, MedXQA-MM)? My original question, *\"How does HALMES handle hallucinations beyond object nouns, such as wrong attributes, wrong counts, OCR mistakes, or reasoning errors?\"*, is still not fully answered."+ },+ "createdAt": "2026-07-30T07:50:07.229Z",+ "modifiedAt": "2026-11-19T17:05:19.202Z",+ "url": "https://openreview.net/forum?id=O8ShETkdl7¬eId=6bj99sRooa",+ "license": "CC-BY-4.0"+}
reviews/openreview/o8shetkdl7/notes/cntxcdz7sp.json added
+++ b/reviews/openreview/o8shetkdl7/notes/cntxcdz7sp.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "CnTxCdz7sp",+ "replyTo": "yYNMFqrAzq",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer NbG5",+ "content": {+ "comment": "I appreciate the authors’ detailed clarifications, continuous engagement, and the additional experiments conducted during the rebuttal. The explanations of the baseline-specific contrastive branches, selective logit recombination, window-size selection, threshold settings, and training-data statistics substantially improve the paper’s technical clarity. The new experiments across random seeds, disjoint evaluation subsets, non-COCO training, and broader benchmarks also provide meaningful supporting evidence.\n\nMy remaining concern is that generalization beyond object hallucination remains preliminary, mixed, and dependent on the underlying contrastive-decoding method. On MathVista, three of the five HALMES combinations reduce overall accuracy, while the two positive changes are below 1.5 percentage points. PathVQA and MME likewise contain several marginal improvements and category-specific degradations. Furthermore, only 9 of the 30 original comparisons remain statistically significant after correction. HALMES also continues to require model-specific training and calibration. These findings support its effectiveness for in-domain object-hallucination mitigation, but its broader accuracy and cross-domain benefits should be presented as preliminary rather than consistent, and these limitations should be clearly reflected in the final paper.\n\nOverall, the authors have responded constructively and provided substantial new evidence that addresses most of my original concerns. Given their commitment in the Paper Checklist to full open-source the code and support reproducibility, I will increase my score accordingly."+ },+ "createdAt": "2026-08-01T18:07:30.957Z",+ "modifiedAt": "2026-11-19T17:05:19.171Z",+ "url": "https://openreview.net/forum?id=O8ShETkdl7¬eId=CnTxCdz7sp",+ "license": "CC-BY-4.0"+}
reviews/openreview/o8shetkdl7/notes/jznq9lumhk.json added
+++ b/reviews/openreview/o8shetkdl7/notes/jznq9lumhk.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "JzNq9LUmHk",+ "replyTo": "RcH6uPxLR8",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We sincerely thank you for your constructive and thoughtful comments. Your valuable suggestions have been highly helpful in improving the paper and strengthening the quality of its final version. We are pleased that the additional experiments have addressed your concerns, and we greatly appreciate your recognition of the practical value of our work. This recognition means a great deal to us and provides strong encouragement to continue refining and advancing this line of research. We are also sincerely grateful for your decision to raise the rating. Given the opportunity, we will incorporate these results and the corresponding explanations into the final version. Thank you again for your time, careful review, and valuable feedback."+ },+ "createdAt": "2026-08-03T03:35:22.851Z",+ "modifiedAt": "2026-11-19T17:05:18.944Z",+ "url": "https://openreview.net/forum?id=O8ShETkdl7¬eId=JzNq9LUmHk",+ "license": "CC-BY-4.0"+}
reviews/openreview/o8shetkdl7/notes/mofenu3fgq.json added
+++ b/reviews/openreview/o8shetkdl7/notes/mofenu3fgq.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "mOFenu3fGQ",+ "replyTo": "PsCHQ0kjYB",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for carefully reviewing our response and for your continued consideration of our work. We sincerely appreciate the time and attention you devoted to the review process. Your comments have helped us identify areas for further improvement and will be valuable in strengthening the final version of the paper. We are grateful for your thoughtful engagement throughout the discussion."+ },+ "createdAt": "2026-08-03T03:34:07.325Z",+ "modifiedAt": "2026-11-19T17:05:18.946Z",+ "url": "https://openreview.net/forum?id=O8ShETkdl7¬eId=mOFenu3fGQ",+ "license": "CC-BY-4.0"+}
reviews/openreview/o8shetkdl7/notes/mzy70t0bam.json modified
+++ b/reviews/openreview/o8shetkdl7/notes/mzy70t0bam.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair dgVC","content": {- "metareview": "This paper proposes HALMES, a plug-and-play module designed to mitigate object hallucinations in LVLMs. Instead of applying CD indiscriminately at every generation step, HALMES utilizes internal attention features to detect hallucination-prone token segments in real-time. It selectively triggers CD only when a high hallucination risk is predicted, transforming full-stage intervention into a targeted, on-demand correction mechanism. \n\nThe main strengths \n\n•\tThe method successfully addresses the collateral damage caused by constant CD intervention by proposing a targeted, segment-level activation strategy. \n\n•\tHALMES is lightweight and can be integrated with various existing CD methods without altering their core formulations. \n\n•\tThe authors provided extensive additional analyses, including leave-one-feature-out ablations, random/periodic activation controls, and cross-architecture validations on Qwen3.5-9B, strengthening the empirical evidence. \n\n\n(c) The main weaknesses \n\n•\tWhile effective for in-domain object hallucinations, the performance gains on broader multimodal tasks remain preliminary and sometimes yield mixed results or marginal improvements. \n\n•\tThe method relies on fixed, manually calibrated thresholds that require model-specific tuning using a validation set, potentially limiting seamless cross-architecture applicability. \n\nThe authors provided a thorough and convincing rebuttal that systematically addressed the concerns raised in the initial meta-review. \n•\tThey clarified that both decoding branches are computed throughout generation, and HALMES merely gates the logit recombination; thus, the latency difference between triggered and non-triggered samples is negligible, resolving the true computational cost concern. \n\n•\tBy comparing HALMES against frequency-matched random and periodic activation baselines, the authors proved that the performance gains strictly stem from the attention-based risk signal, outperforming the baselines in 90/90 pairwise comparisons. \n\n•\tThey added the requested component-wise ablations, showing all five attention features contribute meaningfully. Furthermore, they demonstrated that the fixed thresholds selected via validation transfer reliably across data distributions within the same LVLM. Following the rebuttal, Reviewer ZKn1 raised their rating to an Accept (5), Reviewer NbG5 expressed satisfaction with the clarifications and stated an intention to raise their score (3), and Reviewer ZNDY confidently maintained a Borderline Accept (4). \n\nThe decision to accept is based on the paper's technically sound approach to a recognized problem in contrastive decoding and the authors' exceptional rebuttal. The initial reservations regarding latency masking, the causal value of the risk signal, and hyperparameter sensitivity were resolved with empirical evidence. Although the method's benefits are most pronounced for object hallucinations and require model-specific calibration, the core contribution, an on-demand, attention-guided intervention mechanism, is well-supported. The consensus among reviewers leans positive, confirming the technical solidity of the framework."+ "metareview": "This paper proposes HALMES, a plug-and-play module designed to mitigate object hallucinations in LVLMs. Instead of applying CD indiscriminately at every generation step, HALMES utilizes internal attention features to detect hallucination-prone token segments in real-time. It selectively triggers CD only when a high hallucination risk is predicted, transforming full-stage intervention into a targeted, on-demand correction mechanism. \n\nThe main strengths \n\n•\tThe method successfully addresses the collateral damage caused by constant CD intervention by proposing a targeted, segment-level activation strategy. \n\n•\tHALMES is lightweight and can be integrated with various existing CD methods without altering their core formulations. \n\n•\tThe authors provided extensive additional analyses, including leave-one-feature-out ablations, random/periodic activation controls, and cross-architecture validations on Qwen3.5-9B, strengthening the empirical evidence. \n\n\n(c) The main weaknesses \n\n•\tWhile effective for in-domain object hallucinations, the performance gains on broader multimodal tasks remain preliminary and sometimes yield mixed results or marginal improvements. \n\n•\tThe method relies on fixed, manually calibrated thresholds that require model-specific tuning using a validation set, potentially limiting seamless cross-architecture applicability. \n\nThe authors provided a thorough and convincing rebuttal that systematically addressed the concerns raised in the initial meta-review. \n•\tThey clarified that both decoding branches are computed throughout generation, and HALMES merely gates the logit recombination; thus, the latency difference between triggered and non-triggered samples is negligible, resolving the true computational cost concern. \n\n•\tBy comparing HALMES against frequency-matched random and periodic activation baselines, the authors proved that the performance gains strictly stem from the attention-based risk signal, outperforming the baselines in 90/90 pairwise comparisons. \n\n•\tThey added the requested component-wise ablations, showing all five attention features contribute meaningfully. Furthermore, they demonstrated that the fixed thresholds selected via validation transfer reliably across data distributions within the same LVLM. Following the rebuttal, Reviewer ZKn1 raised their rating to an Accept (5), Reviewer NbG5 expressed satisfaction with the clarifications and stated an intention to raise their score (3), and Reviewer ZNDY confidently maintained a Borderline Accept (4). \n\nThe decision to accept is based on the paper's technically sound approach to a recognized problem in contrastive decoding and the authors' exceptional rebuttal. The initial reservations regarding latency masking, the causal value of the risk signal, and hyperparameter sensitivity were resolved with empirical evidence. Although the method's benefits are most pronounced for object hallucinations and require model-specific calibration, the core contribution, an on-demand, attention-guided intervention mechanism, is well-supported. The consensus among reviewers leans positive, confirming the technical solidity of the framework.",+ "final_justification": "The authors addressed critical concerns raised during the review process. The extensive additional experiments provided during the rebuttal, including feature ablations, control baselines for CD frequency, and evaluation on new architectures like Qwen3.5-9B, firmly establish the validity of the HALMES framework. Reviewers acknowledged that the paper provides a practical and effective solution to reduce the negative side effects of full-stage contrastive decoding. Because the reasons to accept—technical coherence, thorough empirical validation, and a strong rebuttal—outweigh the remaining limitations regarding out-of-domain generalization, the paper merits acceptance."},"createdAt": "2026-07-20T04:50:57.747Z",- "modifiedAt": "2026-11-18T15:19:18.381Z",+ "modifiedAt": "2026-11-19T04:59:36.313Z","url": "https://openreview.net/forum?id=O8ShETkdl7¬eId=mZY70T0bAm","license": "CC-BY-4.0"}
reviews/openreview/o8shetkdl7/notes/nxnbfigtdy.json added
+++ b/reviews/openreview/o8shetkdl7/notes/nxnbfigtdy.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "nxNbFIGtDY",+ "replyTo": "CnTxCdz7sp",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We sincerely thank you for the continued and constructive discussion. Your thoughtful comments have been very helpful in strengthening the final version of our paper. We sincerely appreciate your positive reassessment and decision to raise the score. Your encouraging feedback has greatly motivated us and reinforced our confidence in the value of this work. Thank you again for your time and consideration."+ },+ "createdAt": "2026-08-02T03:08:15.159Z",+ "modifiedAt": "2026-11-19T17:05:18.982Z",+ "url": "https://openreview.net/forum?id=O8ShETkdl7¬eId=nxNbFIGtDY",+ "license": "CC-BY-4.0"+}
reviews/openreview/o8shetkdl7/notes/nzwjbg9ja8.json added
+++ b/reviews/openreview/o8shetkdl7/notes/nzwjbg9ja8.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "nZwjbg9jA8",+ "replyTo": "5yFglzdSB7",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Additional Clarifications for Reviewer NbG5 (Part 1 / 3)",+ "comment": "We sincerely thank you for your thorough feedback. We appreciate the opportunity to provide further clarification and address the remaining concerns individually below.\n\n### **Q1: Baseline-specific contrastive branch construction and the scope of Eq. (2)**\n\nEq. (2) was introduced to capture the general idea of contrastive decoding, where an alternative prediction branch is constructed using a baseline-specific condition defined by the underlying CD method. Thus, \\(I'\\) and \\(x'\\) denote possible baseline-specific visual or textual conditions, rather than new inputs constructed by HALMES or simultaneous modifications of both modalities. The exact branch construction follows each baseline's original formulation.\n\nFor the baselines evaluated with HALMES, the alternative condition and exact construction of each contrastive branch are summarized below.\n\n| Method | Alternative condition | Construction |\n|---|---|---|\n| **VCD** | Visual condition \\(I'\\) | Applies Gaussian diffusion noise to the original image and computes the alternative logits from the noise-distorted image. |\n| **M3ID** | Visual condition \\(I'\\) | Removes image conditioning to compute language-prior predictions from the textual context and generation history, and contrasts them with the image-conditioned predictions. |\n| **AVISC** | Visual condition \\(I'\\) | Identifies blind tokens that receive disproportionately high attention but carry limited object-discriminative information, then zeros out the remaining visual tokens and computes the alternative logits using only the retained blind tokens. |\n| **SID** | Visual condition \\(I'\\) | Estimates visual-token importance from the preceding visual, instruction, and generated tokens, then retains only the least-important visual tokens after the early decoder layers to construct the alternative branch. |\n| **Self-Aug** | Visual condition \\(I'\\) | Uses the LVLM to select a query-relevant transformation from random cropping, random masking, noise addition, color inversion, horizontal flipping, and vertical flipping, then computes the alternative logits from the transformed image. |\n\n### **Q2: Fixed window length \\(K\\) and its selection**\n\nWindow size K is a fixed inference hyperparameter rather than a value dynamically adjusted for each sample or setting. The statement that K is determined by the training-data segment-length distribution means that it is selected once according to the token-segment lengths in the training set, generally slightly below their average length. For both Qwen3VL and InternVL3.5, the average segment length is approximately 20 tokens, so we set K=15 for each model. For the same LVLM, the same K value is used across all datasets and CD methods.\n\n### **Q3: On-demand correction, parameter settings, and trend-aware state control**\n\nBy “on-demand correction,” we mean that HALMES applies the original CD logit correction only at decoding steps identified as hallucination-prone; otherwise, decoding follows the original branch. This refers to selective application of the correction, rather than selective computation of the contrastive branch. Autoregressive LVLM inference relies on KV caches, so each branch must maintain its own decoding history and produce step-aligned logits throughout generation. Pausing the contrastive branch during inactive steps would require reconstructing its missing states before a later reactivation. Therefore, both branches are advanced at every decoding step, while HALMES determines only whether their logits are recombined.\n\nThe thresholds and counter limits used for each LVLM are reported below.\n\n| LVLM | $\\theta_{\\mathrm{high}}$ | $\\theta_{\\mathrm{low}}$ | Warm-up limit | Cool-down limit |\n|---|---:|---:|---:|---:|\n| **Qwen3VL** | 0.60 | 0.50 | 5 | 5 |\n| **InternVL3.5** | 0.75 | 0.65 | 5 | 5 |\n\nBy “trend-aware,” we mean that HALMES considers the temporal persistence of hallucination risk across consecutive decoding steps, rather than requiring an explicitly positive or monotonic trend in the hallucination-risk score. As shown in Lines 10–18 of Algorithm 1, intervention is activated only when the hallucination-risk score continuously remains above $\\theta_{\\mathrm{high}}$ until the warm-up counter reaches its preset limit, and is deactivated only when the hallucination-risk score continuously remains below $\\theta_{\\mathrm{low}}$ until the cool-down counter reaches its preset limit. This design responds to sustained risk signals while preventing isolated score fluctuations from repeatedly switching the intervention state."+ },+ "createdAt": "2026-07-31T16:41:14.743Z",+ "modifiedAt": "2026-11-19T17:05:19.164Z",+ "url": "https://openreview.net/forum?id=O8ShETkdl7¬eId=nZwjbg9jA8",+ "license": "CC-BY-4.0"+}
reviews/openreview/o8shetkdl7/notes/pschq0kjyb.json added
+++ b/reviews/openreview/o8shetkdl7/notes/pschq0kjyb.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "PsCHQ0kjYB",+ "replyTo": "3vXHgJCVJF",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer ZNDY",+ "content": {+ "comment": "I have carefully reviewed your response. I believe that my current score accurately reflects the rating of the paper, and I have therefore decided to maintain my original score."+ },+ "createdAt": "2026-08-02T08:17:07.402Z",+ "modifiedAt": "2026-11-19T17:05:18.982Z",+ "url": "https://openreview.net/forum?id=O8ShETkdl7¬eId=PsCHQ0kjYB",+ "license": "CC-BY-4.0"+}
reviews/openreview/o8shetkdl7/notes/rch6upxlr8.json added
+++ b/reviews/openreview/o8shetkdl7/notes/rch6upxlr8.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "RcH6uPxLR8",+ "replyTo": "UZolHFUIfA",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer ZKn1",+ "content": {+ "title": "Official Comment by Reviewer ZKn1",+ "comment": "Thank you for the authors’ clarification. I found this paper interesting and meaningful. My main concern when reading the paper was the generalizability of the proposed method. Specifically, I was concerned that additional datasets might be required to determine $\\theta_{\\text{high}}$ and $\\theta_{\\text{low}}$, and that the method might not generalize well across different model architectures.\n\nThe authors’ responses to these two concerns have addressed my reservations. In particular, the demonstrated transferability across data distributions within the same LVLM is meaningful and strengthens the practical value of the proposed method. Therefore, I am willing to raise my rating to **5**. If possible, I hope the authors can include these results in the final version."+ },+ "createdAt": "2026-08-02T19:16:23.048Z",+ "modifiedAt": "2026-11-19T17:05:19.168Z",+ "url": "https://openreview.net/forum?id=O8ShETkdl7¬eId=RcH6uPxLR8",+ "license": "CC-BY-4.0"+}
reviews/openreview/o8shetkdl7/notes/sp7vnqyqnm.json added
+++ b/reviews/openreview/o8shetkdl7/notes/sp7vnqyqnm.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "sp7vnQYQnm",+ "replyTo": null,+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "General Response",+ "comment": "For clarity, we refer to Reviewers NbG5, ZKn1, and ZNDY as R1, R2, and R3, respectively, in the following response.\n\nWe sincerely thank all reviewers and the Area Chair for their time, careful evaluation, constructive feedback, and thoughtful consideration. We are particularly encouraged by the reviewers’ recognition of the significance and practical value of HALMES’s central idea: shifting contrastive decoding from **indiscriminate full-stage intervention** to **targeted intervention on hallucination-prone token segments**.\n\nWe have carefully responded to all individual comments through detailed technical clarifications, additional controlled analyses, and substantial new experiments. Below, we summarize the core contributions of HALMES, the experimental evidence added during the rebuttal, and the scope and broader applicability of our work.\n\n---\n\n### Core Contributions\n\n1. **Token-Segment-Level Hallucination Detection:** HALMES reformulates hallucination detection from isolated, post-hoc classification of generated object nouns into real-time identification of hallucination-prone token segments. By modeling the evolving internal attention patterns over preceding tokens, HALMES enables **early hallucination warning before the corresponding hallucinated object noun is generated**.\n\n2. **Risk-Guided Targeted Contrastive Decoding Paradigm:** HALMES proposes a new risk-guided targeted contrastive decoding paradigm that transforms indiscriminate full-stage intervention into targeted correction on hallucination-prone token segments. Rather than introducing a new contrastive branch, HALMES preserves the original formulation, hyperparameters, and logit-adjustment rule of each CD method, while determining when its correction should be applied. Controlled comparisons with random and periodic activation further demonstrate that the gains arise from **risk-guided localization**, rather than merely reducing the frequency of contrastive decoding.\n\n3. **Lightweight and Extensible Integration:** HALMES employs a lightweight detector and can be integrated with diverse contrastive decoding methods. Once trained and calibrated for an LVLM, the same detector and inference settings are reused across datasets, prompt styles, and CD methods without scenario-specific recalibration. Results across **Qwen3VL-8B, InternVL3.5-8B, and Qwen3.5-9B** further demonstrate the applicability of the proposed paradigm to different LVLM architectures.\n\n---\n\n### Updates of Experimental Results During the Rebuttal\n\n- **Controlled validation of risk-guided activation:** Added random and periodic activation baselines to isolate the value of HALMES’s hallucination-risk signal from the effect of simply applying CD less frequently (**R3**).\n\n- **Component and parameter analyses:** Added leave-one-feature-out ablations, training-data scaling results, window-size sensitivity, threshold sensitivity, and cross-distribution threshold-transfer experiments (**R1, R2, R3**).\n\n- **Efficiency and generation behavior:** Added sample-level trigger rates, active-step ratios, separate latency results for triggered and non-triggered samples, response-length analysis, abstention/refusal rate, and incomplete-answer rate (**R1, R3**).\n\n- **Robustness and reproducibility:** Added confidence intervals, corrected statistical significance tests, three-seed stability evaluations, and evaluations on independently sampled subsets (**R1**).\n\n- **Broader architectural and data evaluation:** Added experiments on Qwen3.5-9B and fully non-COCO training on AMBER, including held-out AMBER detection evaluation and evaluation of object-hallucination mitigation on COCO using the AMBER-trained detector (**R1, R2**).\n\n- **Evaluation beyond the primary setting:** Added results on MME, MathVista, and PathVQA to investigate whether the learned risk patterns and selective intervention mechanism can also provide benefits beyond object-hallucination benchmarks (**R1, R3**).\n\n---\n\n### Scope and Broader Applicability\n\nHALMES primarily targets **object hallucination**, which is a common and representative failure mode in LVLM generation. Accordingly, HALMES is trained with object-hallucination supervision, and our main claims and empirical evaluation focus on detecting precursor token segments before incorrect object mentions and selectively intervening to mitigate object hallucinations.\n\nBeyond this primary scope, the original results on MMHal-Bench and the additional experiments on MME, MathVista, and PathVQA provide encouraging preliminary evidence that the learned hallucination-risk patterns and selective intervention can benefit attribute, counting, position, OCR, reasoning, mathematical, and medical tasks to some extent. If given the opportunity, we will present these findings in the final paper as evidence of the **potential extensibility** of HALMES.\n\n---\n\nWe again sincerely thank all reviewers and the Area Chair for their time, constructive feedback, and thoughtful consideration."+ },+ "createdAt": "2026-08-04T10:03:46.196Z",+ "modifiedAt": "2026-11-19T17:05:18.949Z",+ "url": "https://openreview.net/forum?id=O8ShETkdl7¬eId=sp7vnQYQnm",+ "license": "CC-BY-4.0"+}
reviews/openreview/o8shetkdl7/notes/wsgyofbeim.json added
+++ b/reviews/openreview/o8shetkdl7/notes/wsgyofbeim.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "wsgYofBEim",+ "replyTo": "mZY70T0bAm",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "**Response to the AC Summary**\n\nThank you for the careful synthesis. We are encouraged that the reviewers recognize HALMES’s motivation and significance, particularly its shift from conventional full-stage contrastive decoding to a hallucination-risk-guided targeted intervention paradigm. We also appreciate their recognition of our evaluation across five CD methods and our rescue/collateral-risk analyses.\n\nWe address the five concerns below:\n\n1. **Activation frequency and actual inference cost.** \nWe clarified that the average latency does not mask a substantially higher computation cost when HALMES is activated. In the official implementations of all evaluated full-stage CD methods, the original and contrastive branches are computed throughout generation. HALMES **only gates whether the available logits are contrastively recombined at each step**. Averaged across five CD methods, the sample-level trigger rates are 66.0%/65.6%, and the active-step ratios are 71.31%/73.17% on Qwen3VL-8B/InternVL3.5-8B. The triggered and non-triggered latencies are 11.3205/11.2951 s and 12.0134/11.8713 s, respectively, differing by only 0.0254 s and 0.1421 s. These measurements confirm that the observed latency difference arises from gating the logit-recombination operation, rather than from conditionally computing the contrastive branch. \n\n2. **Technical scope and value of risk-guided activation.**\n\n- **Contrastive branch.** HALMES strictly inherits each baseline’s distorted-input construction, contrastive branch, hyperparameters, and logit-adjustment rule. It introduces neither a new distorted input nor an additional contrastive branch.\n\n- **Risk-guided activation.** We evaluated six random and periodic intervention policies across multiple reduced activation rates, including settings close to HALMES’s active-step ratio. Our analysis (Reviewer **ZNDY, Q1**) confirms that these reduced-frequency policies do not consistently improve full-stage CD and all worsen CHAIR$_i$. In contrast, HALMES achieves the best average performance on all three metrics and consistently outperforms these baselines across all five CD methods. This indicates that the **gains arise from the attention-based risk signal rather than merely applying CD less frequently**.\n\n3. **Contribution of the five attention-derived features.** \nWe further conducted controlled leave-one-feature-out ablations (Reviewer **ZNDY, Q2**) for both hallucination detection and mitigation on Qwen3VL-8B and InternVL3.5-8B. Removing any feature decreases AUROC and increases FPR on both models, while every ablation degrades at least one hallucination-mitigation metric. VAR has the largest individual impact, and the remaining features provide complementary information. The full feature set achieves the strongest overall detection performance and the lowest average CHAIR$_i$ and CHAIR$_s$ across all five CD methods on both LVLMs.\n\n4. **Threshold sensitivity and practical calibration.**\n\n- **Transferability across scenarios.** In all reported experiments for a given LVLM, HALMES uses a single detector and the same fixed threshold configuration across all datasets, prompt styles, and five CD methods, without scenario-specific recalibration. The consistent gains in our main results therefore already provide evidence of transferability within the same LVLM. Our additional transfer experiment (Reviewer **ZKn1, Q1**) further shows that the setting selected on AMBER remains the best among the tested candidates on both hallucination metrics on a disjoint COCO subset, supporting transfer across data distributions.\n\n- **Practical selection.** HALMES does not require a validation set matched to each new OOD scenario. Thresholds are calibrated once on a small generic image batch using an \"FPR budget and hysteresis gap\" to balance hallucination reduction with coverage, then reused across datasets and prompts.\n\n5. **Informativeness and non-object hallucinations.**\n\n- **Informativeness trade-off.** Our response-behavior analysis (Reviewer **ZNDY, Q4**) shows that HALMES’s gains are not achieved by shortening or suppressing responses. Because some hallucinations resemble normal generation in attention patterns, false activations may suppress visually weak but correct details, occasionally lowering Coverage or Bingo. Threshold-sensitivity analysis (Table 4 of the paper) shows that, relative to the highest-Coverage setting, the default reduces Coverage by **2.45 pp** while lowering hallucination by **14 pp**, reflecting a controlled trade-off.\n\n- **Non-object hallucinations.** Although HALMES is trained using MSCOCO/CHAIR object localizations, it models hallucination-precursor patterns in attention dynamics rather than specific object identities. Our additional experiments (Reviewer **NbG5, Q4**) show improved total scores in all **10/10** backbone–CD combinations and improved commonsense reasoning in **9/10**, with further gains in counting, position, OCR, and other non-object categories."+ },+ "createdAt": "2026-07-29T06:47:27.020Z",+ "modifiedAt": "2026-11-19T17:05:19.239Z",+ "url": "https://openreview.net/forum?id=O8ShETkdl7¬eId=wsgYofBEim",+ "license": "CC-BY-4.0"+}
reviews/openreview/o8shetkdl7/notes/xpkqlg8uyq.json added
+++ b/reviews/openreview/o8shetkdl7/notes/xpkqlg8uyq.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "xpKqLG8UyQ",+ "replyTo": null,+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Area Chair dgVC",+ "content": {+ "title": "Quick reminder",+ "comment": "Dear reviewers,\n\nThanks to those who have already joined the discussion.\nFor anyone who has not yet, the authors’ rebuttals are available. Please take a moment to read them and join the discussion.\n\nBest,\n\nAC"+ },+ "createdAt": "2026-08-01T00:49:30.258Z",+ "modifiedAt": "2026-11-19T17:05:19.080Z",+ "url": "https://openreview.net/forum?id=O8ShETkdl7¬eId=xpKqLG8UyQ",+ "license": "CC-BY-4.0"+}
reviews/openreview/o8shetkdl7/notes/yynmfqrazq.json added
+++ b/reviews/openreview/o8shetkdl7/notes/yynmfqrazq.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "yYNMFqrAzq",+ "replyTo": "1CPFMcPNng",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Additional Clarifications for Reviewer NbG5 (Part 3 / 3)",+ "comment": "### **Q5: Scope and generalization beyond object hallucination**\n\nHallucination in LVLMs is a broad problem that covers multiple error types. Following the taxonomy in [1], typical multimodal hallucinations are commonly categorized into object, attribute, and relation hallucinations. HALMES primarily focuses on object hallucination, which is a representative and prevalent failure mode in LVLM generation, and its detector is therefore trained using token segments preceding hallucinated object nouns.\n\nThe core contribution of HALMES is to detect hallucination-prone token segments from the model's internal attention patterns and selectively activate contrastive decoding. Although the detector is supervised using token segments preceding hallucinated object nouns, we hypothesize that different hallucination types may share certain abnormal internal patterns that distinguish them from faithful generation. The results in R1-Table 2 offer preliminary evidence consistent with this hypothesis: HALMES yields improvements over the corresponding CD baselines on Count, Position, Color, OCR, and Reasoning categories. These results suggest that the learned risk patterns may partially transfer beyond object nouns, but the current evidence remains limited and does not demonstrate comprehensive coverage of all hallucination types.\n\nTo further address the reviewer's question regarding the effectiveness of HALMES beyond image captioning and hallucination-specific benchmarks, we conduct a small-scale evaluation on two suggested domains. Specifically, we evaluate Qwen3VL-8B on 500 examples from the MathVista test-mini split and 500 examples from the PathVQA test split.\n\n**Table 1: Results on 500 examples from MathVista test-mini split.**\n\n| Method | ALL | FQA | GPS | MWP | TQA | VQA | ALG | ARI | GEO | LOG | NUM | SCI | STA |\n|---|---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|\n| Nucleus | 72.20 | 78.57 | 75.93 | 81.05 | 69.62 | 52.17 | 73.65 | 65.05 | 74.80 | 38.46 | 39.74 | 69.49 | 85.92 |\n| VCD | 71.80 | 77.78 | 74.07 | 82.11 | 69.62 | 52.17 | 72.30 | 68.28 | 73.17 | 30.77 | 37.18 | 71.19 | 85.92 |\n| VCD + HALMES | 72.60 | 78.57 | 75.93 | 84.21 | 70.89 | 50.00 | 73.65 | 66.13 | 74.80 | 38.46 | 41.03 | 72.88 | 85.92 |\n| M3ID | 71.40 | 77.78 | 74.07 | 81.05 | 70.89 | 50.00 | 72.97 | 64.52 | 73.98 | 46.15 | 34.62 | 71.19 | 84.51 |\n| M3ID + HALMES | 70.40 | 81.75 | 70.37 | 81.05 | 67.09 | 46.74 | 69.59 | 63.98 | 69.92 | 38.46 | 32.05 | 67.80 | 89.44 |\n| AVISC | 72.40 | 80.95 | 77.78 | 82.11 | 70.89 | 45.65 | 75.68 | 64.52 | 76.42 | 38.46 | 34.62 | 71.19 | 87.32 |\n| AVISC + HALMES | 72.20 | 76.98 | 72.22 | 84.21 | 73.42 | 52.17 | 72.97 | 66.67 | 72.36 | 38.46 | 39.74 | 69.49 | 84.51 |\n| SID | 72.20 | 80.16 | 74.07 | 78.95 | 73.42 | 51.09 | 72.97 | 66.13 | 73.17 | 30.77 | 33.33 | 74.58 | 88.73 |\n| SID + HALMES | 70.80 | 80.95 | 71.30 | 76.84 | 70.89 | 50.00 | 70.95 | 64.52 | 70.73 | 30.77 | 35.90 | 71.19 | 89.44 |\n| Self-Aug | 72.20 | 77.78 | 75.00 | 83.16 | 70.89 | 51.09 | 72.97 | 67.20 | 73.98 | 23.08 | 35.90 | 71.19 | 86.62 |\n| Self-Aug + HALMES | **73.40** | 80.95 | 76.85 | 83.16 | 70.89 | 51.09 | 74.32 | 67.74 | 75.61 | 38.46 | 37.18 | 72.88 | 88.03 |\n\n**Table 2: Results on 500 examples from the PathVQA test split.**\n\n| Method | Yes/No Accuracy (%) | Free-form Accuracy (%) | Overall Accuracy (%) |\n|---|---:|---:|---:|\n| Nucleus | 67.21 | 6.25 | 36.00 |\n| VCD | 65.16 | 9.38 | 36.60 |\n| VCD + HALMES | 66.80 | 8.59 | 37.00 |\n| M3ID | 63.11 | 4.69 | 33.20 |\n| M3ID + HALMES | 66.39 | 5.86 | 35.40 |\n| AVISC | 66.39 | 5.86 | 35.40 |\n| AVISC + HALMES | 67.62 | 6.64 | 36.40 |\n| SID | 64.34 | 7.42 | 35.20 |\n| SID + HALMES | 69.26 | 8.20 | **38.00** |\n| Self-Aug | 66.39 | 7.81 | 36.40 |\n| Self-Aug + HALMES | 65.98 | 7.81 | 36.20 |\n\nOn MathVista, Self-Aug + HALMES achieves the best overall score. Across the 65 CD-method–metric comparisons, HALMES improves 30, degrades 28, and leaves 7 unchanged. On PathVQA, SID + HALMES achieves the best overall accuracy. Across the 15 comparisons, HALMES improves 11, degrades 3, and leaves 1 unchanged. These results show that HALMES can benefit several mathematical and medical task settings, while its effects are not uniformly positive across all CD methods and capabilities.\n\nWhile HALMES primarily targets object-hallucination mitigation, these results suggest that its selective intervention mechanism can also benefit some broader multimodal tasks. We acknowledge the current limitations and will investigate broader supervision and evaluation settings in future work.\n\n---\n\n**Reference:**\n\n[1] Bai, Zechen, et al. \"Hallucination of multimodal large language models: A survey.\" arXiv preprint arXiv:2404.18930 (2024)."+ },+ "createdAt": "2026-07-31T16:44:36.381Z",+ "modifiedAt": "2026-11-19T17:05:19.104Z",+ "url": "https://openreview.net/forum?id=O8ShETkdl7¬eId=yYNMFqrAzq",+ "license": "CC-BY-4.0"+}