AVI-HT: Adaptive Vision-IMU Fusion for 3D Gloved Hand Tracking
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 20:36 UTC · 76461cb0044c ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,27 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "CzwKVs3kov"- }- ],- "title": "AVI-HT: Adaptive Vision-IMU Fusion for 3D Gloved Hand Tracking",- "authors": [- "Ziyi Kou",- "Ankit Kumar",- "Mia Huang",- "Taylor Niehues",- "Vatsal Mehta",- "Ergys Ristani",- "Li Guan"- ],- "abstract": "We present AVI-HT, an adaptive visual-IMU fusion approach for tracking 3D hand poses by jointly modeling the egocentric images with on-glove 6-DoF IMU signals. AVI-HT significantly improved accuracy and availability, particularly in hand-object interaction (HOI) scenarios involving heavy visual occlusion. Two complementary ingredients underpin its success: (1) synchronized multi-modal training data pairing on-body vision-IMU sensor streams with ground-truth 3D hand poses from a motion-capture system, and (2) a cross-sensor deep attention mechanism that adaptively modulates the trust assigned to the vision and individual IMU sensors. To evaluate AVI-HT in real-world settings, we conduct extensive experiments on our DexGloveHOI dataset that consists of 100K+ pairwise vision-IMU samples with synchronized 3D annotated poses, in which users manipulate a variety of objects during daily tasks. We compare against multiple single- and multi-modal tracking approaches under two hand models (UmeTrack, MANO). The results show that AVI-HT reduces mean keypoint error by 16.1% and its wrist-aligned variant by 24.2% over the baselines. A hand-object contact evaluation shows that AVI-HT keeps finger contacts with the manipulated object more accurately and consistently over time, reducing contact losses by 8.5%. Ablation studies further show that our fusion design outperforms simpler schemes and that the gains grow with occlusion and hold across subjects.",- "year": 2026,- "venue": "NeurIPS 2026",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "a5cfbd9a-1f63-4f33-bf06-24a09eb65c7f"}
paper.json added
+++ b/paper.json@@ -0,0 +1,17 @@+{+ "title": "AVI-HT: Adaptive Vision-IMU Fusion for 3D Gloved Hand Tracking",+ "authors": [+ "Ziyi Kou",+ "Ankit Kumar",+ "Mia Huang",+ "Taylor Niehues",+ "Vatsal Mehta",+ "Ergys Ristani",+ "Li Guan"+ ],+ "abstract": "We present AVI-HT, an adaptive visual-IMU fusion approach for tracking 3D hand poses by jointly modeling the egocentric images with on-glove 6-DoF IMU signals. AVI-HT significantly improved accuracy and availability, particularly in hand-object interaction (HOI) scenarios involving heavy visual occlusion. Two complementary ingredients underpin its success: (1) synchronized multi-modal training data pairing on-body vision-IMU sensor streams with ground-truth 3D hand poses from a motion-capture system, and (2) a cross-sensor deep attention mechanism that adaptively modulates the trust assigned to the vision and individual IMU sensors. To evaluate AVI-HT in real-world settings, we conduct extensive experiments on our DexGloveHOI dataset that consists of 100K+ pairwise vision-IMU samples with synchronized 3D annotated poses, in which users manipulate a variety of objects during daily tasks. We compare against multiple single- and multi-modal tracking approaches under two hand models (UmeTrack, MANO). The results show that AVI-HT reduces mean keypoint error by 16.1% and its wrist-aligned variant by 24.2% over the baselines. A hand-object contact evaluation shows that AVI-HT keeps finger contacts with the manipulated object more accurately and consistently over time, reducing contact losses by 8.5%. Ablation studies further show that our fusion design outperforms simpler schemes and that the gains grow with occlusion and hold across subjects.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}