potentialpaper

AVI-HT: Adaptive Vision-IMU Fusion for 3D Gloved Hand Tracking

Update NeurIPS 2026 submission CzwKVs3kov: 19 notes

@openreview[bot] · 2026-11-24 15:47 UTC · 8c39873a0906 ·

Evidence

reviews/openreview/czwkvs3kov/notes/1bqowlb6jh.json added

+++ b/reviews/openreview/czwkvs3kov/notes/1bqowlb6jh.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "1bQoWLB6JH",
+ "replyTo": "Rr216aN8iq",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer WnMa,\n\nThanks again for your feedback. We wanted to gently follow up on our rebuttal, where we addressed your comments. We'd be glad to hear any further thoughts or answer any remaining questions."
+ },
+ "createdAt": "2026-07-30T09:31:33.321Z",
+ "modifiedAt": "2026-11-19T17:12:22.882Z",
+ "url": "https://openreview.net/forum?id=CzwKVs3kov&noteId=1bQoWLB6JH",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/czwkvs3kov/notes/1ksaoikrsk.json added

+++ b/reviews/openreview/czwkvs3kov/notes/1ksaoikrsk.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "1kSAoiKrSk",
+ "replyTo": "kU5bqfhtdK",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We sincerely thank the reviewer for the encouraging assessment and the clear, actionable suggestions. We have run exactly the experiments the reviewer specified as decisive for the score, and the results below confirm both conditions.\n\n**Q1. Quantify the occlusion claim: errors for visible vs. occluded joints / occlusion subgroups.**\n\nTo quantify the occlusion claim as suggested, we use the camera parameters and 3D ground truth to label each keypoint as occluded or visible per frame, and then bin the frames by the number of occluded keypoints, reporting F.MKPE and F.MKPE.T (the metrics most sensitive to the finger-mounted IMUs). As the table shows, the AVI-HT advantage grows monotonically with occlusion severity, from a 3.5–3.9 mm gap in the least-occluded bin to 6.2–7.5 mm in the most-occluded bin. The results confirm that the gains are concentrated on occluded joints and scale directly with occlusion severity.\n\n| Occluded keypoints | F.MKPE UMETrack | F.MKPE AVI-HT | F.MKPE Gap | F.MKPE.T UMETrack | F.MKPE.T AVI-HT | F.MKPE.T Gap |\n|---|---|---|---|---|---|---|\n| [0, 5) | 16.525 | 13.034 | **3.491** | 16.532 | 12.605 | **3.927** |\n| [5, 10) | 16.704 | 13.226 | **3.478** | 17.383 | 12.745 | **4.638** |\n| [10, 15) | 17.835 | 13.373 | **4.462** | 18.744 | 12.936 | **5.808** |\n| [15, 20) | 21.741 | 15.539 | **6.202** | 21.067 | 13.585 | **7.482** |\n\n**Q2. Ablations: concat, cross-attention without kinematic mask, single-stage without modality rebalancing.**\n\nIn terms of the requested ablations, we report all variants below.\n- **Early concat:** no attention; vision and IMU backbone features are concatenated and linearly projected.\n- **Late fusion:** a separate IMU pose decoder; only the predicted joint angles from the vision and IMU branches are fused at the output.\n- **Pooled IMU token:** average-pool all IMU tokens instead of taking the last token after the transformer.\n- **Fusion-1 only:** remove the second-level self-attention.\n- **w/o k-prior:** remove the kinematic-prior mask from the first-level attention.\n\nBoth the kinematic prior (w/o k-prior) and the second-stage rebalancing (fusion-1 only) yield consistent improvements, while the much simpler fusion approaches (early concat / late fusion) are clearly worse. This indicates that the gains stem from the proposed hierarchical, topology-aware design rather than from the added IMU features or extra parameters alone.\n\n| Model | MKPE | F.MKPE | MKPE.T | F.MKPE.T | P.A | P.A.T |\n|---|---|---|---|---|---|---|\n| UMETrack | 12.342 | 17.478 | 9.359 | 17.798 | 76.059 | 81.433 |\n| AVI-HT (early concat) | 11.928 | 16.935 | 8.649 | 16.545 | 76.208 | 82.629 |\n| AVI-HT (late fusion) | 12.139 | 16.492 | 7.054 | 13.233 | 75.818 | 85.825 |\n| AVI-HT (pooled IMU token) | 11.956 | 14.571 | 7.940 | 14.427 | 76.213 | 84.027 |\n| AVI-HT (fusion-1 only) | 11.113 | 14.088 | 7.456 | 13.740 | 77.818 | 84.994 |\n| AVI-HT (w/o k-prior) | 10.901 | 13.898 | 7.406 | 13.611 | 78.238 | 85.090 |\n| **AVI-HT (full)** | **10.359** | **13.253** | **7.021** | **12.785** | **79.315** | **85.859** |\n\nWe hope these results address the reviewer's concerns, and we would be glad to run any further analyses or clarify any remaining questions during the discussion period."
+ },
+ "createdAt": "2026-07-29T07:37:22.035Z",
+ "modifiedAt": "2026-11-19T17:12:23.196Z",
+ "url": "https://openreview.net/forum?id=CzwKVs3kov&noteId=1kSAoiKrSk",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/czwkvs3kov/notes/4ahzrbdudx.json modified

+++ b/reviews/openreview/czwkvs3kov/notes/4ahzrbdudx.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair e7nF",
"content": {
- "metareview": "Summary: proposes a practical vision-IMU fusion approach for 3D hand tracking during severe occlusion, together with a novel synchronized dataset (DexGloveHOI).\n\nStrengths: Two important contributions: addressing visual occlusion in hand-object interaction using a complementary multimodal approach; the newly collected DexGloveHOI dataset, featuring MoCap supervision and extensive sensor-level analysis.\n\nWeaknesses: concerns regarding limited subject diversity, unclear evaluation protocols, and a lack of rigorous baseline comparisons against multimodal fusion approaches. \n\nDecision: Accept - all 4 reviews are accept leaning and many of the weaknesses raised with comprehensively discussed during the rebuttal."
+ "metareview": "Summary: proposes a practical vision-IMU fusion approach for 3D hand tracking during severe occlusion, together with a novel synchronized dataset (DexGloveHOI).\n\nStrengths: Two important contributions: addressing visual occlusion in hand-object interaction using a complementary multimodal approach; the newly collected DexGloveHOI dataset, featuring MoCap supervision and extensive sensor-level analysis.\n\nWeaknesses: concerns regarding limited subject diversity, unclear evaluation protocols, and a lack of rigorous baseline comparisons against multimodal fusion approaches. \n\nDecision: Accept - all 4 reviews are accept leaning and many of the weaknesses raised with comprehensively discussed during the rebuttal.",
+ "final_justification": "See above."
},
"createdAt": "2026-08-23T09:17:30.473Z",
- "modifiedAt": "2026-11-18T15:19:36.110Z",
+ "modifiedAt": "2026-11-19T04:59:47.355Z",
"url": "https://openreview.net/forum?id=CzwKVs3kov&noteId=4AHZrbduDx",
"license": "CC-BY-4.0"
}

reviews/openreview/czwkvs3kov/notes/b990jwdz8g.json added

+++ b/reviews/openreview/czwkvs3kov/notes/b990jwdz8g.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "B990jWDZ8G",
+ "replyTo": "ymSgmvGxIc",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer xo2Z,\n\nThank you for your review again. As the discussion deadline approaches, we want to kindly follow up on our rebuttal, which we hope has addressed your concerns. We'd be glad to clarify anything further, and hope you'll consider our responses when finalizing your assessment."
+ },
+ "createdAt": "2026-08-02T05:29:56.634Z",
+ "modifiedAt": "2026-11-19T17:12:22.980Z",
+ "url": "https://openreview.net/forum?id=CzwKVs3kov&noteId=B990jWDZ8G",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/czwkvs3kov/notes/c5w6vy0luc.json added

+++ b/reviews/openreview/czwkvs3kov/notes/c5w6vy0luc.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "C5W6vy0LUc",
+ "replyTo": "lj5boKxKKY",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the reviewer for the valuable suggestions and address each question below.\n\n**Q1. Comparisons against strong learned fusion baselines.**\nWe have implemented all of the requested variants.\n- **Early concat:** no attention; vision and IMU backbone features are concatenated and linearly projected.\n- **Late fusion:** a separate IMU pose decoder; only the predicted joint angles from the vision and IMU branches are fused at the output.\n- **Pooled IMU token:** average-pool all IMU tokens instead of taking the last token after the transformer.\n- **Fusion-1 only:** remove the second-level self-attention.\n- **w/o k-prior:** remove the kinematic-prior mask from the first-level attention.\n\n| Model | MKPE | F.MKPE | MKPE.T | F.MKPE.T | P.A | P.A.T |\n|---|---|---|---|---|---|---|\n| UMETrack | 12.342 | 17.478 | 9.359 | 17.798 | 76.059 | 81.433 |\n| AVI-HT (early concat) | 11.928 | 16.935 | 8.649 | 16.545 | 76.208 | 82.629 |\n| AVI-HT (late fusion) | 12.139 | 16.492 | 7.054 | 13.233 | 75.818 | 85.825 |\n| AVI-HT (pooled IMU token) | 11.956 | 14.571 | 7.940 | 14.427 | 76.213 | 84.027 |\n| AVI-HT (fusion-1 only) | 11.113 | 14.088 | 7.456 | 13.740 | 77.818 | 84.994 |\n| AVI-HT (w/o k-prior) | 10.901 | 13.898 | 7.406 | 13.611 | 78.238 | 85.090 |\n| **AVI-HT (full)** | **10.359** | **13.253** | **7.021** | **12.785** | **79.315** | **85.859** |\n\nWe observe that all of these baselines trail the full model, and the naive baselines do so by a wide margin. The reason is that IMU calibration and synchronization noise is non-negligible, so unconditional fusion degrades the fully-visible case in which vision alone already suffices. The attention design instead raises the IMU weight only when its occlusion-driven benefit outweighs that noise, which is what delivers the consistent gains.\n\n**Q2. Are the vision-only baselines fine-tuned on the same gloved-hand DexGloveHOI training data? How much does glove appearance degrade them vs. bare hands?**\n\nFirstly we would like to clarify that all baselines and AVI-HT are trained on the same separate large-scale (~8 million) glove-manipulation training set and DexGloveHOI is used only for evaluation. They therefore serve exactly as the identical-backbone baselines requested, which isolates the contribution of the IMU fusion. \n\nHowever, isolating the effect of glove appearance alone is not a defined problem in our setting. Fine-tuning adapts the model jointly to the glove appearance and to the dataset's objects, interactions, and cameras, so a bare-hand comparison would conflate all of these factors and could not cleanly attribute any change to the glove itself. We would also gently note that bare-hand input is not an operating point of AVI-HT. Since the IMUs are mounted on the glove, glove-vision together with on-glove IMU constitutes a single sensing modality, and a bare-hand configuration is undefined for the fused system.\n\n**Q3. Sensitivity to glove placement, calibration quality, and sensor layout across users.**\n\nIn terms of sensitivity to glove placement, calibration, and layout, Figure 7 of our paper reports two relevant studies: on IMU signal noise and on CV–IMU temporal misalignment,. The results show measurable but bounded sensitivity, with the IMU-side perturbations having the larger effect. Regarding user-level variability specifically, the per-subject results below show consistent gains with only small variance across all four participants, which indicates that the improvement stems from the CV–IMU fusion itself rather than from over-fitting to any single subject's glove placement or sensor layout.\n\n| Participant | MKPE | F.MKPE | MKPE.T | F.MKPE.T | P.A | P.A.T |\n|---|---|---|---|---|---|---|\n| Subject 1 | 10.847 | 13.841 | 7.069 | 12.792 | 78.324 | 85.762 |\n| Subject 2 | 9.624 | 12.190 | 6.548 | 12.469 | 80.797 | 86.811 |\n| Subject 3 | 11.266 | 14.448 | 7.722 | 13.814 | 77.486 | 84.450 |\n| Subject 4 | 8.852 | 11.512 | 6.266 | 11.311 | 82.333 | 87.371 |"
+ },
+ "createdAt": "2026-07-29T07:40:36.581Z",
+ "modifiedAt": "2026-11-19T17:12:23.299Z",
+ "url": "https://openreview.net/forum?id=CzwKVs3kov&noteId=C5W6vy0LUc",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/czwkvs3kov/notes/f7jbdxnv8v.json added

+++ b/reviews/openreview/czwkvs3kov/notes/f7jbdxnv8v.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "f7JBdXnv8V",
+ "replyTo": null,
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "General Response (to all reviewers)",
+ "comment": "We thank all reviewers for their constructive feedback. Several concerns were raised by multiple reviewers, so we consolidate the shared results here for convenience; each reviewer's individual reply is self-contained and covers these points in full along with its reviewer-specific responses.\n\n**Setup.** AVI-HT is trained on a separate ~8M-image glove dataset; DexGloveHOI is evaluation-only and disjoint in subjects, sessions, and tasks. The UMETrack and HaMeR baselines are fine-tuned on the same training set (vision-only, same backbones), isolating the IMU-fusion contribution.\n\n**(1) Fusion ablations.** We compare AVI-HT against simple fusion baselines and component removals. Naive fusion (early concat, late fusion) is clearly worse, and both the kinematic prior (w/o k-prior) and the second-level attention (fusion-1 only) give consistent gains. The improvement stems from the hierarchical, topology-aware design, not from added IMU features or parameters.\n\n| Model | MKPE | F.MKPE | MKPE.T | F.MKPE.T | P.A | P.A.T |\n|---|---|---|---|---|---|---|\n| UMETrack | 12.342 | 17.478 | 9.359 | 17.798 | 76.059 | 81.433 |\n| AVI-HT (early concat) | 11.928 | 16.935 | 8.649 | 16.545 | 76.208 | 82.629 |\n| AVI-HT (late fusion) | 12.139 | 16.492 | 7.054 | 13.233 | 75.818 | 85.825 |\n| AVI-HT (pooled IMU token) | 11.956 | 14.571 | 7.940 | 14.427 | 76.213 | 84.027 |\n| AVI-HT (fusion-1 only) | 11.113 | 14.088 | 7.456 | 13.740 | 77.818 | 84.994 |\n| AVI-HT (w/o k-prior) | 10.901 | 13.898 | 7.406 | 13.611 | 78.238 | 85.090 |\n| **AVI-HT (full)** | **10.359** | **13.253** | **7.021** | **12.785** | **79.315** | **85.859** |\n\n**(2) Occlusion vs. severity.** Labeling each keypoint occluded/visible from camera parameters and 3D GT pose and binning by occluded-keypoint count, the AVI-HT − UMETrack gap grows monotonically with occlusion, i.e., the gain concentrates where vision is lost.\n\n| Occluded keypoints | F.MKPE UMETrack | F.MKPE AVI-HT | F.MKPE Gap | F.MKPE.T UMETrack | F.MKPE.T AVI-HT | F.MKPE.T Gap |\n|---|---|---|---|---|---|---|\n| [0, 5) | 16.525 | 13.034 | **3.491** | 16.532 | 12.605 | **3.927** |\n| [5, 10) | 16.704 | 13.226 | **3.478** | 17.383 | 12.745 | **4.638** |\n| [10, 15) | 17.835 | 13.373 | **4.462** | 18.744 | 12.936 | **5.808** |\n| [15, 20) | 21.741 | 15.539 | **6.202** | 21.067 | 13.585 | **7.482** |\n\n**(3) Per-subject generalization.** On the held-out DexGloveHOI subjects, AVI-HT improves consistently with small variance, indicating the gains come from CV–IMU fusion rather than subject-specific overfitting.\n\n| Participant | MKPE | F.MKPE | MKPE.T | F.MKPE.T | P.A | P.A.T |\n|---|---|---|---|---|---|---|\n| Subject 1 | 10.847 | 13.841 | 7.069 | 12.792 | 78.324 | 85.762 |\n| Subject 2 | 9.624 | 12.190 | 6.548 | 12.469 | 80.797 | 86.811 |\n| Subject 3 | 11.266 | 14.448 | 7.722 | 13.814 | 77.486 | 84.450 |\n| Subject 4 | 8.852 | 11.512 | 6.266 | 11.311 | 82.333 | 87.371 |\n\n**(4) Latency.** Per-stage timing of the AVI-HT-UME forward pass (unoptimized); the IMU stages add <7 ms, and on-device quantization yields ~31 ms hand-tracking (within ~70 ms motion-to-photon).\n\n| Stage | Image processing | IMU filtering | Synchronization | Fusion | Pose regression |\n|---|---|---|---|---|---|\n| Time | 82.522 ms | 3.085 ms | 3.059 ms | 0.006 ms | 49.484 ms |"
+ },
+ "createdAt": "2026-07-29T08:01:43.655Z",
+ "modifiedAt": "2026-11-19T17:12:23.352Z",
+ "url": "https://openreview.net/forum?id=CzwKVs3kov&noteId=f7JBdXnv8V",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/czwkvs3kov/notes/fuvv8wrofb.json added

+++ b/reviews/openreview/czwkvs3kov/notes/fuvv8wrofb.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "FUVv8wROfb",
+ "replyTo": "kU5bqfhtdK",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer CyHe,\n\nThank you for your review again. As the discussion deadline approaches, we want to kindly follow up on our rebuttal, which we hope has addressed your concerns. We'd be glad to clarify anything further, and hope you'll consider our responses when finalizing your assessment."
+ },
+ "createdAt": "2026-08-02T05:30:29.665Z",
+ "modifiedAt": "2026-11-19T17:12:22.798Z",
+ "url": "https://openreview.net/forum?id=CzwKVs3kov&noteId=FUVv8wROfb",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/czwkvs3kov/notes/fyt5jiy5rh.json added

+++ b/reviews/openreview/czwkvs3kov/notes/fyt5jiy5rh.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "FYT5jIy5Rh",
+ "replyTo": "2MeR2HkGRl",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer qJkQ,\n\nThanks again for your feedback. We wanted to gently follow up on our rebuttal, where we addressed your comments. We'd be glad to hear any further thoughts or answer any remaining questions."
+ },
+ "createdAt": "2026-07-30T09:29:59.326Z",
+ "modifiedAt": "2026-11-19T17:12:23.051Z",
+ "url": "https://openreview.net/forum?id=CzwKVs3kov&noteId=FYT5jIy5Rh",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/czwkvs3kov/notes/hpnakrhdgx.json added

+++ b/reviews/openreview/czwkvs3kov/notes/hpnakrhdgx.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "hPNaKrHdgx",
+ "replyTo": "Rr216aN8iq",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the reviewer for the detailed comments and address each point below.\n\n**Q1. Stronger justification for the hierarchical cross-sensor attention.**\n\nWe present an ablation isolating each component of the design:\n- **Early concat:** concatenate backbone features + linear projection (no attention).\n- **Late fusion:** separate IMU decoder; fuse predicted joint angles at the output.\n- **Pooled IMU token:** average-pool all IMU tokens vs. the last token.\n- **Fusion-1 only:** drop the second-level self-attention.\n- **w/o k-prior:** drop the kinematic-prior mask.\n\n| Model | MKPE | F.MKPE | MKPE.T | F.MKPE.T | P.A | P.A.T |\n|---|---|---|---|---|---|---|\n| UMETrack | 12.342 | 17.478 | 9.359 | 17.798 | 76.059 | 81.433 |\n| AVI-HT (early concat) | 11.928 | 16.935 | 8.649 | 16.545 | 76.208 | 82.629 |\n| AVI-HT (late fusion) | 12.139 | 16.492 | 7.054 | 13.233 | 75.818 | 85.825 |\n| AVI-HT (pooled IMU token) | 11.956 | 14.571 | 7.940 | 14.427 | 76.213 | 84.027 |\n| AVI-HT (fusion-1 only) | 11.113 | 14.088 | 7.456 | 13.740 | 77.818 | 84.994 |\n| AVI-HT (w/o k-prior) | 10.901 | 13.898 | 7.406 | 13.611 | 78.238 | 85.090 |\n| **AVI-HT (full)** | **10.359** | **13.253** | **7.021** | **12.785** | **79.315** | **85.859** |\n\nAs the table shows, each hierarchical level and the kinematic prior contributes, and naive fusion (early concat / late fusion) is clearly worse. The reason is that IMU calibration/synchronization noise is non-negligible, so undifferentiated fusion hurts when the hand is fully visible; the attention up-weights IMU evidence only where occlusion makes its benefit exceed that noise. This adaptive behavior is what distinguishes the design from merely adding IMU features or parameters.\n\n**Q2. More thorough ablation over the number and placement of IMUs.**\n\nFigure 6 (Per-finger IMU contribution) already provides this ablation, beyond the per-joint breakdown in Figure 4. In the left fiture, for each IMU sensor group (rows) and evaluated finger (columns), we report the MKPE.T Gap when only that group is provided, which directly quantifying both placement and sensor count. The diagonal entries (sensor and finger coincide) consistently yield the largest improvement, confirming each IMU mainly benefits its own finger, while the smaller but positive off-diagonal entries reflect kinematic coupling between neighboring fingers. Each row thus shows what is gained or lost as a sensor is added or removed.\n\nMore generally, the layout is fixed across training and evaluation, but the architecture is not bound to it: the cross-sensor attention uses a geodesic mask over the hand skeleton rather than fixed sensor indices, so a different count/placement needs no architectural change.\n\n**Q3. Substantiate the Line-167 claim.**\n\nWe would like to point to the two experimental observations on which it rests. First, in Figure 6 (per-finger IMU contribution), each finger's IMU provides the largest reduction in that same finger's MKPE, which shows that the model routes each sensor primarily to its anatomically corresponding finger. Second, in the qualitative study of Figure 1, the IMU sensors whose fingers are occluded from the camera receive noticeably higher attention weights than the others. Taken together, these observations indicate that the attention adaptively increases reliance on the corresponding-finger IMU precisely when that finger is occluded.\n\n**Q4. Gravity-vector extraction; does it survive fast motion where linear acceleration contaminates the accelerometer?**\n\nWe would like to clarify that gravity is not read directly from the accelerometer. Instead, each IMU runs an accelerometer+gyroscope orientation filter (EKF-style, without a magnetometer), and we take the gravity vector as the vertical axis of the fused orientation. This design is robust to fast motion because the gyroscope drives the orientation estimate and is immune to linear acceleration, while the accelerometer contributes only a low-bandwidth pitch/roll correction that filters down-weights during high dynamics. Consequently, bursts of motion acceleration are ridden out by gyroscope integration and the estimate is re-anchored once the hand slows, so the extracted gravity vector remains reliable even during rapid movement.\n\n**Q5. Explain IMU placement and the data tensor.**\n\nIn terms of placement, the 12 IMUs are arranged as three on the thumb, two on each of the remaining four fingers, and one on the dorsum. In terms of the data tensor, the IMU window is 14×23×3: the 14 is the number of temporal samples, and the 23 stacks two derived features from the 12 IMUs: a gravity 3-vector per IMU (12 in total) and a wrist-relative gyroscope 3-vector, gyroₖ − gyro_wrist, for each non-reference IMU (11 in total). This yields 12 + 11 = 23 three-vectors per frame, each fed to the network as one token.\n\n**Q6. Minor typos.**\n\nWe thank the reviewer for catching these typos and will correct both in the revised paper."
+ },
+ "createdAt": "2026-07-29T07:51:31.376Z",
+ "modifiedAt": "2026-11-19T17:12:23.276Z",
+ "url": "https://openreview.net/forum?id=CzwKVs3kov&noteId=hPNaKrHdgx",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/czwkvs3kov/notes/leqqlhdtwp.json added

+++ b/reviews/openreview/czwkvs3kov/notes/leqqlhdtwp.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "LeqQlhdTWP",
+ "replyTo": "U2XYFsExWf",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the reviewer WnMa for the thoughtful follow-up and for raising the score.\n\nThe model handles both placement and number through the fixed 12-slot layout. For placement, although the mask values are relative geodesic distances, the mask is indexed to a fixed ordering from thumb to pinky, so each slot receives its own bias row and its absolute position is encoded without a separate positional embedding. For number, any absent sensor is zero-masked in its own slot rather than re-indexed, so each remaining sensor keeps its absolute identity while attention attends only to the active ones.\n\nWe are happy to provide any further clarification if needed."
+ },
+ "createdAt": "2026-08-02T07:08:20.446Z",
+ "modifiedAt": "2026-11-19T17:12:22.776Z",
+ "url": "https://openreview.net/forum?id=CzwKVs3kov&noteId=LeqQlhdTWP",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/czwkvs3kov/notes/ntitooi3hu.json added

+++ b/reviews/openreview/czwkvs3kov/notes/ntitooi3hu.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "ntITOOI3hu",
+ "replyTo": "kU5bqfhtdK",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer CyHe,\n\nThanks again for your feedback. We wanted to gently follow up on our rebuttal, where we addressed your comments. We'd be glad to hear any further thoughts or answer any remaining questions."
+ },
+ "createdAt": "2026-07-30T09:30:53.801Z",
+ "modifiedAt": "2026-11-19T17:12:23.108Z",
+ "url": "https://openreview.net/forum?id=CzwKVs3kov&noteId=ntITOOI3hu",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/czwkvs3kov/notes/nuy6pdyrff.json added

+++ b/reviews/openreview/czwkvs3kov/notes/nuy6pdyrff.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "nUY6pDyRff",
+ "replyTo": "ymSgmvGxIc",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the reviewer for the careful reading.\n\n**Q1. Data splits.**\n\nAVI-HT is trained on a separate ~8M-image glove dataset; DexGloveHOI is evaluation-only. The two are disjoint in subjects, sessions, and tasks, so the split is subject-/session-disjoint with no adjacent-frame leakage.\n\n**Q2. UMETrack and HaMeR Finetuning**\n\nBoth UMETrack and HaMeR are fine-tuned on the same training set, vision-only, with AVI-HT's backbones, i.e., the identical-backbone baselines requested, which isolates the IMU-fusion contribution. We also implemented all requested fusion variants:\n- **Early concat:** concatenate backbone features + linear projection (no attention).\n- **Late fusion:** separate IMU decoder; fuse predicted joint angles at the output.\n- **Pooled IMU token:** average-pool all IMU tokens vs. the last token.\n- **Fusion-1 only:** drop the second-level self-attention.\n- **w/o k-prior:** drop the kinematic-prior mask.\n\n| Model | MKPE | F.MKPE | MKPE.T | F.MKPE.T | P.A | P.A.T |\n|---|---|---|---|---|---|---|\n| UMETrack | 12.342 | 17.478 | 9.359 | 17.798 | 76.059 | 81.433 |\n| AVI-HT (early concat) | 11.928 | 16.935 | 8.649 | 16.545 | 76.208 | 82.629 |\n| AVI-HT (late fusion) | 12.139 | 16.492 | 7.054 | 13.233 | 75.818 | 85.825 |\n| AVI-HT (pooled IMU token) | 11.956 | 14.571 | 7.940 | 14.427 | 76.213 | 84.027 |\n| AVI-HT (fusion-1 only) | 11.113 | 14.088 | 7.456 | 13.740 | 77.818 | 84.994 |\n| AVI-HT (w/o k-prior) | 10.901 | 13.898 | 7.406 | 13.611 | 78.238 | 85.090 |\n| **AVI-HT (full)** | **10.359** | **13.253** | **7.021** | **12.785** | **79.315** | **85.859** |\n\nThe naive fusion baselines trail the attention design; both the kinematic mask and the second-level attention give consistent gains.\n\n**Q3. Occlusion quantitatively demonstrated.**\n\nWe label each keypoint occluded/visible from camera parameters and 3D GT pose, and bin frames by occluded-keypoint count. We report F.MKPE and F.MKPE.T (most sensitive to the finger-mounted IMUs). The AVI-HT − UMETrack gap grows monotonically with occlusion, i.e., the gain concentrates where vision is lost:\n\n| Occluded keypoints | F.MKPE UMETrack | F.MKPE AVI-HT | F.MKPE Gap | F.MKPE.T UMETrack | F.MKPE.T AVI-HT | F.MKPE.T Gap |\n|---|---|---|---|---|---|---|\n| [0, 5) | 16.525 | 13.034 | **3.491** | 16.532 | 12.605 | **3.927** |\n| [5, 10) | 16.704 | 13.226 | **3.478** | 17.383 | 12.745 | **4.638** |\n| [10, 15) | 17.835 | 13.373 | **4.462** | 18.744 | 12.936 | **5.808** |\n| [15, 20) | 21.741 | 15.539 | **6.202** | 21.067 | 13.585 | **7.482** |\n\n**Q4. IMU tensor; Sensor and camera configuration.**\n\n**IMU tensor.** 14 = temporal window. The 23 = two features from the 12 IMUs: a gravity 3-vector each (12) + a wrist-relative gyro 3-vector (gyroₖ − gyro_wrist) for each non-reference IMU (11), i.e., 23 vectors/frame (14×23×3), one token each.\n\n**Cameras.** The Quest has two egocentric cameras: AVI-HT-UME uses both stereo views (feature-transform layer, per UMETrack); AVI-HT-MANO uses a single 256×192 RGB crop with ViT.\n\n**Q5. Single dataset/glove/layout.**\n\nNo existing dataset provides synchronized egocentric vision, on-glove 6-DoF IMU, and marker-based GT pose for dexterous HOI, so DexGloveHOI was a prerequisite. The layout is fixed across training and DexGloveHOI, but the architecture is not tied to it: the cross-sensor attention uses a geodesic mask over the hand skeleton (not fixed sensor indices), so a different sensor count/placement needs no change. On scope: the same glove is used, but training and DexGloveHOI remain disjoint in subjects, sessions, and tasks (Q1), so we still measure generalization to unseen users/interactions, not train-on-test.\n\n**Q6. Controlled seated setup.**\n\nThe seated setup is required by the ground truth: sub-millimeter marker-based MoCap needs a calibrated, occlusion-minimized volume, constraining the subject to a fixed rig. Single-environment MoCap is standard practice (e.g., Human3.6M, ARCTIC, GRAB, HOT3D), so our protocol follows convention.\n\n**Q7. Inference latency.**\n\nPer-stage timing of the AVI-HT-UME forward pass (unoptimized):\n\n| Stage | Image processing | IMU filtering | Synchronization | Fusion | Pose regression |\n|---|---|---|---|---|---|\n| Time | 82.522 ms | 3.085 ms | 3.059 ms | 0.006 ms | 49.484 ms |\n\nThe IMU-specific stages add <7 ms combined; the cost is dominated by image processing and pose regression (standard CV components). These are full-precision numbers; on-device quantization yields the ~31 ms hand-tracking budget quoted above (within ~70 ms motion-to-photon).\n\n**Q8. Related work: HOOV [1], EgoPoser [2], RPM [3].**\n\nWe thank the reviewer for these pointers. The connection is thematic, not direct: [1] estimates hand-root/full-body pose (we target per-finger articulation); [2] uses a single wrist IMU or inside-out signals (we fuse vision with dense on-glove IMUs); [3] handles full dropout via temporal prediction (we address partial visual degradation via adaptive fusion). We will cite all three to situate our robustness claims."
+ },
+ "createdAt": "2026-07-29T07:31:01.890Z",
+ "modifiedAt": "2026-11-19T17:12:23.352Z",
+ "url": "https://openreview.net/forum?id=CzwKVs3kov&noteId=nUY6pDyRff",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/czwkvs3kov/notes/pzcnrpbgpo.json added

+++ b/reviews/openreview/czwkvs3kov/notes/pzcnrpbgpo.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "PzCnrPBgpO",
+ "replyTo": "lj5boKxKKY",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer FMLP,\n\nThanks again for your feedback. We wanted to gently follow up on our rebuttal, where we addressed your comments. We'd be glad to hear any further thoughts or answer any remaining questions."
+ },
+ "createdAt": "2026-07-30T09:31:11.466Z",
+ "modifiedAt": "2026-11-19T17:12:22.974Z",
+ "url": "https://openreview.net/forum?id=CzwKVs3kov&noteId=PzCnrPBgpO",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/czwkvs3kov/notes/tgm9qfiixr.json added

+++ b/reviews/openreview/czwkvs3kov/notes/tgm9qfiixr.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "tgM9qFIiXr",
+ "replyTo": "2MeR2HkGRl",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We sincerely thank the reviewer for the positive assessment and the thoughtful, constructive suggestions.\n\n**Q1. Generalization to unseen users and environments; subject-independent split, per-subject results.**\n\nWe want to clarify that AVI-HT is trained on a separate, large-scale (~8 million) glove dataset, while the entire DexGloveHOI is held out for evaluation only. The two datasets use disjoint subjects and manipulation tasks by design. This is in fact a stronger form of the subject-independent split requested.\n\nThe two datasets do share a capture environment. However, the IMU modality for fusion is inherently environment-invariant. The on-glove IMU features depend only on the hand's motion and orientation, and are independent of the egocentric viewpoint. The complementary IMU cues that AVI-HT relies on therefore remain equally informative regardless of the surrounding environment.\n\nWe further evaluate the per-participant results on DexGloveHOI, which shows consistent gains over the baselines with only small variance:\n| Participant | MKPE | F.MKPE | MKPE.T | F.MKPE.T | P.A | P.A.T |\n|---|---|---|---|---|---|---|\n| Subject 1 | 10.847 | 13.841 | 7.069 | 12.792 | 78.324 | 85.762 |\n| Subject 2 | 9.624 | 12.190 | 6.548 | 12.469 | 80.797 | 86.811 |\n| Subject 3 | 11.266 | 14.448 | 7.722 | 13.814 | 77.486 | 84.450 |\n| Subject 4 | 8.852 | 11.512 | 6.266 | 11.311 | 82.333 | 87.371 |\n\n**Q2. Ablations**\n\nWe have added the following variants:\n- **Early concat:** no attention; vision and IMU backbone features are concatenated and linearly projected.\n- **Late fusion:** a separate IMU pose decoder; only the predicted joint angles from the vision and IMU branches are fused at the output.\n- **Pooled IMU token:** average-pool all IMU tokens instead of taking the last token after the transformer.\n- **Fusion-1 only:** remove the second-level self-attention.\n- **w/o k-prior:** remove the kinematic-prior mask from the first-level attention.\n\nAs the table shows, each component contributes, and the naive fusion baselines trail the attention-based designs by a clear margin. We attribute this to the non-negligible calibration and synchronization noise in the IMU signals. When the hand is fully visible, vision alone already suffices, and indiscriminately mixing in noisy IMU features tends to hurt. The attention design is precisely what allows the model to raise the IMU weight only when the occlusion-driven benefit outweighs this noise.\n\n| Model | MKPE | F.MKPE | MKPE.T | F.MKPE.T | P.A | P.A.T |\n|---|---|---|---|---|---|---|\n| UMETrack | 12.342 | 17.478 | 9.359 | 17.798 | 76.059 | 81.433 |\n| AVI-HT (early concat) | 11.928 | 16.935 | 8.649 | 16.545 | 76.208 | 82.629 |\n| AVI-HT (late fusion) | 12.139 | 16.492 | 7.054 | 13.233 | 75.818 | 85.825 |\n| AVI-HT (pooled IMU token) | 11.956 | 14.571 | 7.940 | 14.427 | 76.213 | 84.027 |\n| AVI-HT (fusion-1 only) | 11.113 | 14.088 | 7.456 | 13.740 | 77.818 | 84.994 |\n| AVI-HT (w/o k-prior) | 10.901 | 13.898 | 7.406 | 13.611 | 78.238 | 85.090 |\n| **AVI-HT (full)** | **10.359** | **13.253** | **7.021** | **12.785** | **79.315** | **85.859** |\n\n**Q3. MoCap-to-UMETrack.**\n\nWe follow UMETrack to convert the MoCap markers to hand pose. The pose annotations are produced by IK-fitting a personalized, 3DMD-scanned hand model to the labeled optical markers. We measured its per-keypoint 3D error against independent human multi-view keypoint annotations. On held-out subjects, the fit achieves a mean landmark error of 0.8–1.6 mm (≤3.25 mm at the 90th percentile), which is well below the tracking errors we report.\n\n**Q4. Runtime, end-to-end latency, hardware.**\n\nAVI-HT requires a Quest headset and the sensing glove. On-device, the end-to-end budget is ~70 ms motion-to-photon, comprising ~31 ms of hand tracking (after quantization) and ~39 ms of camera-to-display. A full per-stage breakdown of the research forward pass is also provided below. Notably, the IMU related stages together add less than 7 ms, so the added modality is not the runtime bottleneck.\n\n| Stage | Image processing | IMU filtering | Synchronization | Fusion | Pose regression |\n|---|---|---|---|---|---|\n| Time | 82.522 ms | 3.085 ms | 3.059 ms | 0.006 ms | 49.484 ms |\n\n**Q5: Limitations**\n\n**Generalization:** detailed in Q1.\n\n**Robustness:** Figure 7 quantifies robustness to CV–IMU mis-synchronization (stable within ±0.4 s) and to IMU noise. Following IMU-Tracker, we avoid drift-prone integrated orientation and rely on drift-insensitive features: per-IMU gravity vectors and wrist-relative gyroscope, which mitigates both gyroscope drift and calibration drift. Each sensor is rigidly mounted over the corresponding bony phalanx and connected through strain-relieved flex on a single per-hand bus, so finger motion rarely induces signal loss.\n\n**Ethics:** All training data was collected under participant consent with IRB approval. For DexGloveHOI, we are actively completing the institutional legal and data-review process required for public release."
+ },
+ "createdAt": "2026-07-29T06:56:43.645Z",
+ "modifiedAt": "2026-11-19T17:12:23.327Z",
+ "url": "https://openreview.net/forum?id=CzwKVs3kov&noteId=tgM9qFIiXr",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/czwkvs3kov/notes/u2xyfsexwf.json added

+++ b/reviews/openreview/czwkvs3kov/notes/u2xyfsexwf.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "U2XYFsExWf",
+ "replyTo": "hPNaKrHdgx",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer WnMa",
+ "content": {
+ "comment": "I thank the reviewers for their detailed response. The ablation study of their architecture is especially appreciated, since it further justifies their algorithmic contribution.\n\nRegarding the IMU placement ablation, could the authors explain how their model implicitly accounts for the number and placement of IMUs? Aren't the masking tokens that are added in the first stage of the hierarchical cross-sensor attention mechanism only relative? How are the absolute positions of the IMUs being encoded?\n\nIn light of the detailed rebuttal, I upgrade my score from 3 to 4."
+ },
+ "createdAt": "2026-08-02T06:27:08.631Z",
+ "modifiedAt": "2026-11-19T17:12:22.801Z",
+ "url": "https://openreview.net/forum?id=CzwKVs3kov&noteId=U2XYFsExWf",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/czwkvs3kov/notes/uvercfmn4l.json added

+++ b/reviews/openreview/czwkvs3kov/notes/uvercfmn4l.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "uvErcfmN4l",
+ "replyTo": "lj5boKxKKY",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer FMLP,\n\nThank you for your review again. As the discussion deadline approaches, we want to kindly follow up on our rebuttal, which we hope has addressed your concerns. We'd be glad to clarify anything further, and hope you'll consider our responses when finalizing your assessment."
+ },
+ "createdAt": "2026-08-02T05:30:53.001Z",
+ "modifiedAt": "2026-11-19T17:12:22.795Z",
+ "url": "https://openreview.net/forum?id=CzwKVs3kov&noteId=uvErcfmN4l",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/czwkvs3kov/notes/v3ly7qcj5q.json added

+++ b/reviews/openreview/czwkvs3kov/notes/v3ly7qcj5q.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "V3LY7qCj5Q",
+ "replyTo": "Rr216aN8iq",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer WnMa,\n\nThank you for your review again. As the discussion deadline approaches, we want to kindly follow up on our rebuttal, which we hope has addressed your concerns. We'd be glad to clarify anything further, and hope you'll consider our responses when finalizing your assessment."
+ },
+ "createdAt": "2026-08-02T05:31:21.111Z",
+ "modifiedAt": "2026-11-19T17:12:22.800Z",
+ "url": "https://openreview.net/forum?id=CzwKVs3kov&noteId=V3LY7qCj5Q",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/czwkvs3kov/notes/wisfkzgtl5.json added

+++ b/reviews/openreview/czwkvs3kov/notes/wisfkzgtl5.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "WisFkZGtl5",
+ "replyTo": "ymSgmvGxIc",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer xo2Z,\n\nThanks again for your feedback. We wanted to gently follow up on our rebuttal, where we addressed your comments. We'd be glad to hear any further thoughts or answer any remaining questions."
+ },
+ "createdAt": "2026-07-30T09:30:25.705Z",
+ "modifiedAt": "2026-11-19T17:12:23.090Z",
+ "url": "https://openreview.net/forum?id=CzwKVs3kov&noteId=WisFkZGtl5",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/czwkvs3kov/notes/zhdw105qkj.json added

+++ b/reviews/openreview/czwkvs3kov/notes/zhdw105qkj.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "zHDw105qKJ",
+ "replyTo": "2MeR2HkGRl",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewer qJkQ,\n\nThank you for your review again. As the discussion deadline approaches, we want to kindly follow up on our rebuttal, which we hope has addressed your concerns. We'd be glad to clarify anything further, and hope you'll consider our responses when finalizing your assessment."
+ },
+ "createdAt": "2026-08-02T05:29:37.750Z",
+ "modifiedAt": "2026-11-19T17:12:22.852Z",
+ "url": "https://openreview.net/forum?id=CzwKVs3kov&noteId=zHDw105qKJ",
+ "license": "CC-BY-4.0"
+}