potentialpaper

PhysFlow: Physics-Intrinsic Velocity Regularization for Motion-Intensive Video Generation

Update NeurIPS 2026 submission bI9RUy8ZnA: 6 notes

@openreview[bot] · 2026-11-24 15:53 UTC · 380140c69219 ·

Evidence

reviews/openreview/bi9ruy8zna/notes/artyq7cdgt.json modified

+++ b/reviews/openreview/bi9ruy8zna/notes/artyq7cdgt.json
@@ -8,8 +8,8 @@
"content": {
"metareview": "This paper presents PhysFlow, a training-free method for improving text-to-video generation when the prompt involves fast or complex motion. The main idea is to detect when the model’s predicted motion is inconsistent with the changes between nearby video frames, and then slightly adjust the sampling process in those regions. The method is simple, requires no retraining or extra model calls, and adds almost no inference cost. The ablation results also suggest that the proposed residual signal, rather than ordinary temporal smoothing, is the main source of the improvement. \n\nThe main concern, raised by KiC9, 4GJ8, and phYQ, is that the experiments do not yet support the paper’s broad claims. Almost all results are based on Wan2.1. The additional 14B experiment is still within the same model family, and the improvement becomes noticeably smaller. Therefore, the current evidence shows that PhysFlow works on Wan2.1, but not yet that it works generally across flow-based video models. A result on one different backbone, even on a smaller but balanced subset of the benchmark, would be particularly helpful.\n\nThe second concern is that the reported improvements are modest and somewhat uneven, as noted by all three reviewers. Much of the gain on MotionStress-100 comes from the fine-grained physics category, while several other categories improve only slightly. In addition, the main evaluation relies on a single vision-language model judging a newly introduced benchmark. The human study is useful, but it contains only 20 video pairs, and important details such as the number of raters and agreement between raters are missing. The rebuttal should therefore provide uncertainty estimates, fuller human-study details, and ideally results using another VLM judge or an analysis of how well the automatic judgments agree with humans.\n\nKiC9 also questions the term “physics-intrinsic”. I view this mainly as an issue of positioning rather than a technical flaw. The method encourages smoother and more consistent motion in latent space, but it does not directly enforce physical laws. The authors should narrow the wording accordingly.\n\nOverall, I do not see a clear correctness problem. A convincing response on cross-model generality and evaluation reliability could significantly improve the assessment; without such evidence, the paper remains borderline because the current experiments are not yet strong enough for the breadth of the claims."
},
"createdAt": "2026-07-19T08:00:08.862Z",
- "modifiedAt": "2026-11-18T15:20:05.320Z",
+ "modifiedAt": "2026-11-19T05:00:03.302Z",
"url": "https://openreview.net/forum?id=bI9RUy8ZnA&noteId=ARtyq7cDGT",
"license": "CC-BY-4.0"
}

reviews/openreview/bi9ruy8zna/notes/bfknh9tj6j.json added

+++ b/reviews/openreview/bi9ruy8zna/notes/bfknh9tj6j.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "BfKNH9Tj6j",
+ "replyTo": "swEzrc7jAB",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer phYQ",
+ "content": {
+ "title": "comments",
+ "comment": "As the rebuttal response mainly resolved my concerns, I will maintain my score (Borderline Accept)."
+ },
+ "createdAt": "2026-08-03T03:06:35.787Z",
+ "modifiedAt": "2026-11-19T16:56:59.614Z",
+ "url": "https://openreview.net/forum?id=bI9RUy8ZnA&noteId=BfKNH9Tj6j",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/bi9ruy8zna/notes/ncuhrkygjy.json added

+++ b/reviews/openreview/bi9ruy8zna/notes/ncuhrkygjy.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "ncUhRKYgjy",
+ "replyTo": "STsBCnBnzY",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer 4GJ8",
+ "content": {
+ "comment": "Thank you for the detailed rebuttal. The additional experiments address most of my concerns, so I will raise my score to 4."
+ },
+ "createdAt": "2026-08-03T13:16:14.823Z",
+ "modifiedAt": "2026-11-19T16:56:59.359Z",
+ "url": "https://openreview.net/forum?id=bI9RUy8ZnA&noteId=ncUhRKYgjy",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/bi9ruy8zna/notes/ssss9klquy.json added

+++ b/reviews/openreview/bi9ruy8zna/notes/ssss9klquy.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "SsSs9KlQUy",
+ "replyTo": "ncUhRKYgjy",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Thank you very much for your positive feedback. We are glad that the additional experiments and clarifications addressed your concerns. We sincerely appreciate your thoughtful evaluation and helpful suggestions, which have improved our work. We are very grateful for your decision to raise the score to 4."
+ },
+ "createdAt": "2026-08-03T13:27:44.536Z",
+ "modifiedAt": "2026-11-19T16:56:59.551Z",
+ "url": "https://openreview.net/forum?id=bI9RUy8ZnA&noteId=SsSs9KlQUy",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/bi9ruy8zna/notes/stsbcnbnzy.json added

+++ b/reviews/openreview/bi9ruy8zna/notes/stsbcnbnzy.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "STsBCnBnzY",
+ "replyTo": "xBd7voeu9q",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Additional Residual Analysis on Wan2.1-14B",
+ "comment": "We thank the reviewer for this helpful suggestion and repeat the residual-evolution analysis in Figure 8 on Wan2.1-14B. Residuals at different sampling steps are sequential observations along the same ODE trajectory rather than independent samples; therefore, endpoint differences represent net trajectory changes rather than accumulated intervention effects. Moreover, because the residual is a model-dependent internal control signal rather than a calibrated quality metric, its absolute magnitude should not be compared across backbone sizes. We therefore focus on within-backbone trajectory changes.\n\nAfter the initial transient, the intensive- and simple-motion baseline curves remain relatively stable, with the intensive-motion baseline generally higher within each backbone, supporting the residual’s sensitivity to motion difficulty. We report three trajectory statistics: *active-stage reduction*, the residual decrease while PhysFlow is enabled; *post-intervention rebound*, the residual increase after PhysFlow is disabled; and *final baseline–PhysFlow gap*, the remaining separation between PhysFlow and the intensive-motion baseline at the final step.\n\n| Backbone | Active-stage reduction, Step 5→35 | Post-intervention rebound, Step 35→50 | Final baseline–PhysFlow gap |\n| --- | --- | --- | --- |\n| 1.3B | 0.46 | 0.36 | 0.23 |\n| 14B | 0.50 | 0.43 | 0.18 |\n\nThe active-stage reduction is comparable across the two backbones and slightly larger on 14B. Thus, the smaller perceptual gain on 14B cannot be simply attributed to a weaker active-stage correction. After PhysFlow is disabled, however, 14B exhibits a somewhat larger rebound and retains a smaller final separation from its own baseline. This rebound does not by itself imply degraded video quality, because the residual is not a calibrated perceptual metric and the final 30% of sampling is reserved for the pretrained dynamics to refine appearance details. Together with the stronger 14B baseline and its smaller remaining perceptual headroom, this within-backbone behavior is consistent with the smaller final improvement observed on 14B."
+ },
+ "createdAt": "2026-08-03T10:18:00.113Z",
+ "modifiedAt": "2026-11-19T16:56:59.356Z",
+ "url": "https://openreview.net/forum?id=bI9RUy8ZnA&noteId=STsBCnBnzY",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/bi9ruy8zna/notes/wl9yzqifyx.json added

+++ b/reviews/openreview/bi9ruy8zna/notes/wl9yzqifyx.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "Wl9YzQIfyX",
+ "replyTo": "BfKNH9Tj6j",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Additional Evaluation under Different Sampling-Step Budgets",
+ "comment": "We sincerely appreciate the reviewer’s acknowledgment that our rebuttal mainly resolve the concerns. We hope that these additional results and the clarified practical operating range further address the remaining concern and support a reconsideration of the assessment.\n\n**Robustness to reduced sampling steps.** We thank the reviewer for highlighting the practical importance of few-step generation. We evaluate PhysFlow using 10 and 30 sampling steps while keeping the sampler and all other settings unchanged.\n\nPhysFlow improves the average MotionStress score from **57.06 to 63.00 (+5.94)** at 10 steps and from **64.33 to 68.67 (+4.34)** at 30 steps. It improves **9 of the 10 category–step combinations**. Importantly, because PhysFlow is applied over approximately 70% of the sampling trajectory, the 10-step setting provides only about seven active correction steps. The consistent improvement under this setting shows that the active schedule remains sufficiently dense for PhysFlow to operate effectively and that its benefit is preserved under commonly used reduced-step sampling.\n\nThese results refine the limitation stated in the original manuscript. The concern does not apply to the tested 10-step setting, but primarily to more aggressively compressed regimes, such as one- or very-few-step distilled models. In such cases, PhysFlow would have only one or a few opportunities to correct the trajectory, while the large transition between consecutive states may also weaken the local temporal smoothness assumption underlying the inter-frame derivative. We will revise the limitation to make this operating boundary clearer.\n\n| Category | Baseline (10 steps) | PhysFlow (10 steps) | Baseline (30 steps) | PhysFlow (30 steps) |\n| --- | --- | --- | --- | --- |\n| Linear Motion | 57.78 | 61.11 | 65.00 | 68.89 |\n| Human / Complex Motion | 38.89 | 47.22 | 50.56 | 55.00 |\n| Fluid / Particle Dynamics | 79.17 | 85.83 | 90.00 | 89.17 |\n| Camera Motion | 49.44 | 56.67 | 54.44 | 62.78 |\n| Fine-grained Physics | 60.00 | 64.17 | 61.67 | 67.50 |\n| Average | 57.06 | 63.00 | 64.33 | 68.67 |"
+ },
+ "createdAt": "2026-08-03T08:41:35.350Z",
+ "modifiedAt": "2026-11-19T16:56:59.411Z",
+ "url": "https://openreview.net/forum?id=bI9RUy8ZnA&noteId=Wl9YzQIfyX",
+ "license": "CC-BY-4.0"
+}