NeuralBES: A Differentiable, Control-Aware Emulator for Scalable Building Energy Modeling
Update NeurIPS 2026 submission BK43ekBKEC: 6 notes
@openreview[bot] · 2026-11-24 15:47 UTC · 7986e872b1cb ·
reviews/openreview/bk43ekbkec/notes/4jdljutt3p.json modified
+++ b/reviews/openreview/bk43ekbkec/notes/4jdljutt3p.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair xYKH","content": {- "metareview": "The authors propose a new neural emulator for building energy simulation. All reviewers agree on the novelty of the contribution and the general potential for impact of this work, also praising the quality of the presentation and writing. While two reviewers provide accept scores, they do so with lower confidence. Reviewer q6HF has the highest confidence score and currently recommends rejection based on several shortcomings, most importantly the fairness of the comparisons conducted in the study and claims around the approaches transferrability. I'd strongly encourage the authors to engage with this detailed review as I believe it highlights several areas of improvement of the current manuscript."+ "metareview": "The authors propose a new neural emulator for building energy simulation. All reviewers agree on the novelty of the contribution and the general potential for impact of this work, also praising the quality of the presentation and writing. While two reviewers provide accept scores, they do so with lower confidence. Reviewer q6HF has the highest confidence score and currently recommends rejection based on several shortcomings, most importantly the fairness of the comparisons conducted in the study and claims around the approaches transferrability. I'd strongly encourage the authors to engage with this detailed review as I believe it highlights several areas of improvement of the current manuscript.",+ "final_justification": "The authors submitted substantial rebuttals to the reviewers, leading to a great discussion with reviewer q6HF. Overall, the authors responded positively to the rebuttal and the paper now has all accept scores. I also encourage the authors to integrate some of the suggestions made by the reviewers after the rebuttal, especially 6qt2's suggestion on integrating more practical examples into the writing to contextualize the work. Furthermore, there's one hallucinated reference in the paper:\n@article{zhang2021grey,\n author = {Zhe Zhang and Adrian Chong and Yuzhen Pan and Chi Zhang and Khee Poh Lam},\n title = {Grey-box modeling and application for building energy simulations—a critical review},\n journal = {Renewable and Sustainable Energy Reviews},\n volume = {146},\n pages = {111174},\n year = {2021},\n doi = {10.1016/j.rser.2021.111174}\n}\nThe authors in the provided citation ('Zhe Zhang', 'Adrian Chong', 'Yuzhen Pan', 'Chi Zhang', 'Khee Poh Lam') are completely incorrect. The actual authors of the paper are Yanfei Li, Zheng O'Neill, Liang Zhang, Jianli Chen, Piljae Im, and Jason DeGraw.\n\nI recommend acceptance."},"createdAt": "2026-07-21T22:39:07.828Z",- "modifiedAt": "2026-11-18T15:20:08.448Z",+ "modifiedAt": "2026-11-19T05:00:05.385Z","url": "https://openreview.net/forum?id=BK43ekBKEC¬eId=4JdLjutT3p","license": "CC-BY-4.0"}
reviews/openreview/bk43ekbkec/notes/77g2d0yw9g.json added
+++ b/reviews/openreview/bk43ekbkec/notes/77g2d0yw9g.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "77G2d0yw9G",+ "replyTo": "uFAfoD1S0C",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer q6HF",+ "content": {+ "comment": "Thanks for the extra experiments and thoughtful rebuttal to my review. Responses below:\n\n**1. Transfer and scalability (W1–W2, Limitation 2)**\n\nGot it, thanks for the updated experiments. LGTM regarding transferability. I understand your input-side claim and I do agree with you there (and also suspect there are practical scalability benefits) but I do think regarding scalability, it would make the paper stronger if it is explicitly shown, since it is indeed used as a major motivation. If there is anything reasonable you could still add during the rebuttal period, I would encourage you to explore this further.\n\n**2. Capacity-matched LSTM (W5, Limitation 1)**\n\nThank you for investigating this and presenting updated results / claims. This is important for transparency.\n\n**3. LSTM clipping and signed (LSTM Baseline Feasibility)**\n\nAck.\n\n**4. RC topology, encoder sharing, and physics-aware baselines (W3–W4)**\n\n*Topology/RC baseline.* Thank you for correcting the part about the 3R2C model. This is a very vital detail for comparability.\n\nHowever, it is still unclear to me how you chose/configured the Gray-box RC model? You say you use the same static encoder architecture, and the same node/conductance topology, but internal gains does not seem to be learned in the gray-box model (lines 248-252), so what did you use here instead (since you also said yourself that ResStock does not always have ground-truth). I don't mean to be tedious, but I do not think you adequately explain how this model was developed, how it differs, or if it is sophisticated or commonly used, which is quite important in determining both the fairness of baseline as well as the novelty of NeuralBES. Also, you explain in lines 248-252 which parameters the baseline learns, and what NeuralBES learns on top, but there is not an adequate discussion or clarity (in my opinion) of if these extra learned parameters are novel, relative to previous studies. For example, until the log-space scan and predictor–corrector control, NeuralBES is essentially a formulation of a gray-box model, where you choose these certain parameters to learn.\n\nSo concretely: why is this subset of learned parameters the best choice for a baseline / state-of-the-art in gray-box RC models, and how novel are those extra learned parameters you added?\n\n*Static encoder.* Got it, thanks. Yes, it is important to clarify this.\n\n*Physics-aware comparison.* Ack.\n\n**5. Why loads matter; thermostat scope (W6)**\n\nSounds good regarding the thermostat limitation and the caveat with Fig 3. \n\nAlso thanks for clarifying about the relevance of the Qheat and Qcool outputs, because I now better understand what you are targeting. I would recommend emphasizing this point more about why Q is important, because it helps better-position your intended contribution, which gets diluted by the poorer T predictions.\n\n**6. Figures 2 and 3 (W7)**\n\n*Figure 2.* Ack.\n\n*Figure 3.* To be honest, I am not sure how much I agree with these statements since it is sometimes difficult to see the NeuralBES line in Figure 7, but if your point is that the temperature envelope / range of NeuralBES is closer to the actual than the others, then yes, the $|\\Delta T_{air}|$ would achieve this as well.\n\n**7. Protocol and minor clarifications**\n\n*Training windows.* Ack.\n\n*Exogenous inputs.* Ack. FWIW, this is simply important for transparency and applicability -- does not take much away from your study in my opinion.\n\n*Notation.* Ack. If you're running out of space, Appendix is also fine, but just as long as a reader can find it.\n\n----\n\nThanks to the authors again for their thoughtful responses and engagement to address my feedback -- much appreciated. Your provided updates and clarifications surely improve the quality and scientific integrity of the paper. I unfortunately still have doubts about the novelty/level of contribution, as well as the baselines (see **(4)**), so I will await your response before considering my score change."+ },+ "createdAt": "2026-08-01T14:32:22.391Z",+ "modifiedAt": "2026-11-19T17:13:39.526Z",+ "url": "https://openreview.net/forum?id=BK43ekBKEC¬eId=77G2d0yw9G",+ "license": "CC-BY-4.0"+}
reviews/openreview/bk43ekbkec/notes/aktwax2t3n.json added
+++ b/reviews/openreview/bk43ekbkec/notes/aktwax2t3n.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "aKtwax2T3n",+ "replyTo": null,+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Area Chair xYKH",+ "content": {+ "title": "End of discussion period approaching",+ "comment": "Dear reviewers, there's about 1 day left in the discussion period and the authors have posted their rebuttal. If you have any remaining questions or topics you'd want to discuss with the authors, please do this as soon as possible."+ },+ "createdAt": "2026-08-03T02:51:38.434Z",+ "modifiedAt": "2026-11-19T17:13:39.362Z",+ "url": "https://openreview.net/forum?id=BK43ekBKEC¬eId=aKtwax2T3n",+ "license": "CC-BY-4.0"+}
reviews/openreview/bk43ekbkec/notes/cfxjdwqceq.json added
+++ b/reviews/openreview/bk43ekbkec/notes/cfxjdwqceq.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "cfXjdwQcEq",+ "replyTo": "77G2d0yw9G",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for asking us to sharpen the novelty claim. We agree that NeuralBES belongs to the broad family of grey-box models, but respectfully argue that it is not a conventional grey-box model with a larger hand-selected parameter set. Our contribution is not a new resistance, capacitance, infiltration law, or COP curve in isolation; it is the identification and simulation regime that unifies these established components.\n\n**First, NeuralBES replaces per-building identification with population-amortized identification.** Conventional grey-box methods estimate a parameter vector $\\theta_b$ from measurements collected from the same building $b$, generally including its observed indoor temperature and HVAC heat input. A new building therefore requires another identification or calibration run. NeuralBES instead learns a shared map $g_\\phi(s_b) \\mapsto \\theta_b$ from static descriptors $s_b$ to building-specific thermal, infiltration, internal-gain, and equipment coefficients. At inference, an unseen building receives these coefficients without fitting to any portion of its target trajectory. Our leave-one-region-out results further show that this map can be applied when the entire evaluation region is absent from training. To our knowledge, amortizing this metadata-to-physics identification across a heterogeneous building population, rather than fitting each building independently, is novel.\n\n**Second, NeuralBES provides an end-to-end differentiable implementation of a control-coupled RC model.** Conventional RC temperature models generally treat HVAC heat as an observed forcing. NeuralBES instead closes the thermostat–temperature loop through a capacity-constrained predictor–corrector, making $Q_{\\mathrm{heat}}$, $Q_{\\mathrm{cool}}$, and $T_{\\mathrm{air}}$ self-consistent outputs. We combine this controller with a log-space scan that preserves gradients across the complete 672-step training window, whereas our sequential RC implementation detaches its state every 48 steps. The scan and predictor–corrector each have precedent; the contribution is their integration with population-conditioned coefficients into a jointly trained load-and-temperature simulator.\n\nThe novelty boundary for the individual components is therefore:\n\n| Component | Prior status | NeuralBES contribution |\n|---|---|---|\n| Internal gains, wind infiltration, and COP derating | Established BEM terms | Building-conditioned effective coefficients learned jointly without coefficient labels |\n| RC coefficients and equipment capacities | Established physical parameters | Predicted zero-shot from metadata instead of fitted on the target building |\n| Scheduled setpoints | Established control inputs | Incorporated into the endogenous load–temperature loop |\n| Log-space scan and predictor–corrector | Established numerical ideas | Combined into a differentiable, control-coupled RC rollout |\n\n**Why does the RC baseline stop at its chosen parameter set?** There is no universally optimal RC order; the grey-box literature selects model complexity according to the application and information available. Nevertheless, our stopping point is principled. A conventional per-building fit must restrict its free coefficients to those that can be reliably estimated from one building's limited trajectory, which is precisely why that literature uses model-order selection. Our reference therefore predicts every resistance and capacitance in the same 3R2C topology as NeuralBES, plus solar aperture and heating/cooling capacities required for the three benchmark outputs. It also includes internal gains through one population-level linear map from the 17 schedule channels.\n\nThe population objective can support additional building-specific degrees of freedom because their metadata-to-parameter map is constrained jointly across thousands of buildings rather than estimated independently for each building. We do not claim that the resulting coefficients are uniquely identifiable; they are end-task-identified effective parameters. This distinction is central: the additional terms are not new physics, but estimating and coupling them in this population-amortized regime is part of the contribution.\n\nThus, NeuralBES's novelty is the unification of population-level zero-shot identification, endogenous load–temperature coupling, and differentiable long-horizon simulation. To our knowledge, the cited grey-box, PCNN, PINN, and neural-ODE studies do not demonstrate this combination in a single metadata-to-physics model evaluated on unseen buildings and regions. We thank the reviewer for prompting us to make this boundary explicit and will revise the paper accordingly."+ },+ "createdAt": "2026-08-03T20:53:24.894Z",+ "modifiedAt": "2026-11-19T17:13:39.265Z",+ "url": "https://openreview.net/forum?id=BK43ekBKEC¬eId=cfXjdwQcEq",+ "license": "CC-BY-4.0"+}
reviews/openreview/bk43ekbkec/notes/qo4srgdtaa.json added
+++ b/reviews/openreview/bk43ekbkec/notes/qo4srgdtaa.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "QO4SRgdTAA",+ "replyTo": "cfXjdwQcEq",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer q6HF",+ "content": {+ "comment": "**Novelty**\n\nWhile I agree that learning a shared map based on a several buildings is helpful, I think the claim that amortizing metadata-to-physics identification across a heterogeneous building population is novel is overstated. For example, the Bayesian hierarchical calibration study from Kristensen et al. 2018 [1] already assigns physical parameters to unseen buildings from metadata alone, learned from a heterogeneous population, with no measurements on the target (and FWIW, archetype-based UBEM such as TABULA and ResStock essentially use metadata to sample/map to building physical characteristics to do the modeling in the first place...). Furthermore, the proposed shared map is a regression whose prediction quality relies heavily on having many building types to train on (ex. the same architecture trained on a single building would be structurally identical but would fail to transfer). Training across a population therefore does not introduce a new inferential mechanism, but rather supplies enough coverage of descriptor space to make an otherwise ill-posed regression identifiable. So it seems like a data-coverage argument, not a methodological one.\n\nAs I see it, the authors' delta relative to this line of work is (i) conditioning on a richer continuous descriptor vector rather than a discrete archetype class, and (ii) fitting the map end-to-end through the RC dynamics and corrective steps. Both are reasonable but should be claimed at that scale, with the above and others positioned as prior related works.\n\nAs an aside, regarding the point about HVAC heat, off the top of my head I do not know any studies that do this so cannot make direct claims about its novelty, so will not push back here. However, I would urge the authors to confirm with a thorough literature review that this is indeed correct.\n\n[1] Kristensen, Martin Heine, Rasmus Elbæk Hedegaard, and Steffen Petersen. \"Hierarchical calibration of archetypes for urban building energy modeling.\" Energy and Buildings 175 (2018): 219-234.\n\n**RC Baseline**\n\nYes, I understand that there is no universal gray-box baseline, which is why it is important that the baseline here is calibrated in a way that shows the benefits of the authors' *novel* additions, rather than having this conflated with simply having more free parameters. For me, it suffices so long as the authors (1) justify that it is indeed a reasonable and fair comparison and not a hand-selected set of parameters; (2) clearly outline in the manuscript the differences between the baseline and the 3R2C part of NeuralBES. It seems from the last sentence of the authors' response that they are in agreement to do this.\n\n---\n\nUltimately, my feelings about novelty remain unchanged, but I am relatively satisfied with the answer about the RC baseline (so long as it is made explicit in the manuscript how this differs if at all from the RC component of NeuralBES in the end). I think the paper's contribution lies less in the novelty of its methodology but rather in the combination of these established components in a way that makes sense for the application of Building Energy Modeling, and the results seem to at least be effective and more physically consistent in the prediction of Q (but not so much for T), which is relevant for certain downstream tasks as the users describe. Furthermore, the authors addressed many of my concerns, clarified several points, and corrected/updated experiments and the paper's claims.\n\nI have raised my rating to a 4. Despite its weaknesses, this paper indeed has a relevant use case, some interesting ideas, a well-tailored methodology, promising results, and transparency of limitations that could be valuable for the broader community, particularly in its BEM application domain.\n\nExisting weaknesses include: Limited / no benefit for temperature prediction, unvalidated (though plausible) scalability claims, limited methodological novelty beyond combination of existing methods."+ },+ "createdAt": "2026-08-04T07:20:01.559Z",+ "modifiedAt": "2026-11-19T17:13:39.415Z",+ "url": "https://openreview.net/forum?id=BK43ekBKEC¬eId=QO4SRgdTAA",+ "license": "CC-BY-4.0"+}
reviews/openreview/bk43ekbkec/notes/ywyzdptxjb.json added
+++ b/reviews/openreview/bk43ekbkec/notes/ywyzdptxjb.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "ywYzdPTxJb",+ "replyTo": "nMgffJMJYl",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 6qt2",+ "content": {+ "comment": "Thank you for the response, these clarifications on the technical details are helpful. The response also acknowledges my comment about not connecting results to the intended users but doesn't include detail on how or where this will be addressed. Both as a paper in the use-inspired track and to help this work appeal to a broad audience I would like to see some writing change to address this with some explicit application examples (Ex: being better at detecting spiking events is likely useful because it could help show peak demand for capacity planning etc). A good place for this could be either the end of the introduction or a discussion section explaining the implications of the results."+ },+ "createdAt": "2026-08-04T07:04:40.986Z",+ "modifiedAt": "2026-11-19T17:13:39.231Z",+ "url": "https://openreview.net/forum?id=BK43ekBKEC¬eId=ywYzdPTxJb",+ "license": "CC-BY-4.0"+}