NeuralBES: A Differentiable, Control-Aware Emulator for Scalable Building Energy Modeling
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 20:38 UTC · 90d2c8c3e83f ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,24 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "BK43ekBKEC"- }- ],- "title": "NeuralBES: A Differentiable, Control-Aware Emulator for Scalable Building Energy Modeling",- "authors": [- "Ting-Yu Dai",- "Takuya Kurihana",- "Wing Yee Au",- "HON YUNG WONG"- ],- "abstract": "Demand-side flexibility, i.e., forecasting, shifting, and curtailing residential energy loads, depends on thermal models trusted across millions of heterogeneous buildings. Existing tools force a hard tradeoff: high-fidelity physics simulators such as EnergyPlus are accurate but sequential and require per-building calibration, while purely data-driven sequence models scale but abandon the physical structure that makes their predictions trustworthy.\n\nWe introduce NeuralBES (Building Energy Simulation), a differentiable emulator that resolves this tradeoff by parameterizing a resistance--capacitance (RC) based thermal model with a shared neural encoder: static building metadata such as floor area, vintage, and HVAC type is mapped to physically bounded capacitances, conductances, and equipment coefficients, which become the coefficients of a scalar linear recurrence solved via a log-space parallel scan, and a predictor--corrector loop closes the thermostat--temperature nonlinearity while preserving full-horizon gradient flow. Trained on the ResStock dataset across three climate zones, NeuralBES handles heterogeneous building archetypes, vintages, and climate zones within a single trained encoder, while black-box baselines produce statistically plausible but physically inconsistent trajectories. On the annual full-year rollout, NeuralBES reproduces realistic HVAC idle periods and duty cycles, which determine annual energy and peak-load estimates. It reduces the MAPE by more than half compared to an equally sized grey-box RC baseline that shares its metadata encoder, while an unconstrained LSTM attains lower pointwise error.",- "year": 2026,- "venue": "NeurIPS 2026",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "f539ec05-a6a9-4163-b4da-7704bba1af3a"}
paper.json added
+++ b/paper.json@@ -0,0 +1,14 @@+{+ "title": "NeuralBES: A Differentiable, Control-Aware Emulator for Scalable Building Energy Modeling",+ "authors": [+ "Ting-Yu Dai",+ "Takuya Kurihana",+ "Wing Yee Au",+ "HON YUNG WONG"+ ],+ "abstract": "Demand-side flexibility, i.e., forecasting, shifting, and curtailing residential energy loads, depends on thermal models trusted across millions of heterogeneous buildings. Existing tools force a hard tradeoff: high-fidelity physics simulators such as EnergyPlus are accurate but sequential and require per-building calibration, while purely data-driven sequence models scale but abandon the physical structure that makes their predictions trustworthy.\n\nWe introduce NeuralBES (Building Energy Simulation), a differentiable emulator that resolves this tradeoff by parameterizing a resistance--capacitance (RC) based thermal model with a shared neural encoder: static building metadata such as floor area, vintage, and HVAC type is mapped to physically bounded capacitances, conductances, and equipment coefficients, which become the coefficients of a scalar linear recurrence solved via a log-space parallel scan, and a predictor--corrector loop closes the thermostat--temperature nonlinearity while preserving full-horizon gradient flow. Trained on the ResStock dataset across three climate zones, NeuralBES handles heterogeneous building archetypes, vintages, and climate zones within a single trained encoder, while black-box baselines produce statistically plausible but physically inconsistent trajectories. On the annual full-year rollout, NeuralBES reproduces realistic HVAC idle periods and duty cycles, which determine annual energy and peak-load estimates. It reduces the MAPE by more than half compared to an equally sized grey-box RC baseline that shares its metadata encoder, while an unconstrained LSTM attains lower pointwise error.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}