potentialpaper

NeuralBES: A Differentiable, Control-Aware Emulator for Scalable Building Energy Modeling

Keep the title, authors and abstract in paper.json

potentialpaper · 2026-11-23 20:38 UTC · 90d2c8c3e83f ·

.potentialpaper/metadata.json modified

+++ b/.potentialpaper/metadata.json
@@ -1,24 +1,5 @@
{
- "layout": 5,
- "identifiers": [
- {
- "scheme": "openreview",
- "value": "BK43ekBKEC"
- }
- ],
- "title": "NeuralBES: A Differentiable, Control-Aware Emulator for Scalable Building Energy Modeling",
- "authors": [
- "Ting-Yu Dai",
- "Takuya Kurihana",
- "Wing Yee Au",
- "HON YUNG WONG"
- ],
- "abstract": "Demand-side flexibility, i.e., forecasting, shifting, and curtailing residential energy loads, depends on thermal models trusted across millions of heterogeneous buildings. Existing tools force a hard tradeoff: high-fidelity physics simulators such as EnergyPlus are accurate but sequential and require per-building calibration, while purely data-driven sequence models scale but abandon the physical structure that makes their predictions trustworthy.\n\nWe introduce NeuralBES (Building Energy Simulation), a differentiable emulator that resolves this tradeoff by parameterizing a resistance--capacitance (RC) based thermal model with a shared neural encoder: static building metadata such as floor area, vintage, and HVAC type is mapped to physically bounded capacitances, conductances, and equipment coefficients, which become the coefficients of a scalar linear recurrence solved via a log-space parallel scan, and a predictor--corrector loop closes the thermostat--temperature nonlinearity while preserving full-horizon gradient flow. Trained on the ResStock dataset across three climate zones, NeuralBES handles heterogeneous building archetypes, vintages, and climate zones within a single trained encoder, while black-box baselines produce statistically plausible but physically inconsistent trajectories. On the annual full-year rollout, NeuralBES reproduces realistic HVAC idle periods and duty cycles, which determine annual energy and peak-load estimates. It reduces the MAPE by more than half compared to an equally sized grey-box RC baseline that shares its metadata encoder, while an unconstrained LSTM attains lower pointwise error.",
- "year": 2026,
- "venue": "NeurIPS 2026",
- "source": "openreview",
- "license": {
- "metadata": "CC0-1.0",
- "abstract": "CC0-1.0"
- }
+ "layout": 6,
+ "kind": "paper",
+ "key": "f539ec05-a6a9-4163-b4da-7704bba1af3a"
}

paper.json added

+++ b/paper.json
@@ -0,0 +1,14 @@
+{
+ "title": "NeuralBES: A Differentiable, Control-Aware Emulator for Scalable Building Energy Modeling",
+ "authors": [
+ "Ting-Yu Dai",
+ "Takuya Kurihana",
+ "Wing Yee Au",
+ "HON YUNG WONG"
+ ],
+ "abstract": "Demand-side flexibility, i.e., forecasting, shifting, and curtailing residential energy loads, depends on thermal models trusted across millions of heterogeneous buildings. Existing tools force a hard tradeoff: high-fidelity physics simulators such as EnergyPlus are accurate but sequential and require per-building calibration, while purely data-driven sequence models scale but abandon the physical structure that makes their predictions trustworthy.\n\nWe introduce NeuralBES (Building Energy Simulation), a differentiable emulator that resolves this tradeoff by parameterizing a resistance--capacitance (RC) based thermal model with a shared neural encoder: static building metadata such as floor area, vintage, and HVAC type is mapped to physically bounded capacitances, conductances, and equipment coefficients, which become the coefficients of a scalar linear recurrence solved via a log-space parallel scan, and a predictor--corrector loop closes the thermostat--temperature nonlinearity while preserving full-horizon gradient flow. Trained on the ResStock dataset across three climate zones, NeuralBES handles heterogeneous building archetypes, vintages, and climate zones within a single trained encoder, while black-box baselines produce statistically plausible but physically inconsistent trajectories. On the annual full-year rollout, NeuralBES reproduces realistic HVAC idle periods and duty cycles, which determine annual energy and peak-load estimates. It reduces the MAPE by more than half compared to an equally sized grey-box RC baseline that shares its metadata encoder, while an unconstrained LSTM attains lower pointwise error.",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}