potentialpaper

Inertia-1: An Open Exploration of Wearable Motion Foundation Models

Import NeurIPS 2026 submission L4whvxozBR: 8 notes

@openreview[bot] · 2026-11-22 17:56 UTC · eef12475d761

Evidence

.gitattributes added

+++ b/.gitattributes
@@ -0,0 +1,10 @@
+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),
+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.
+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text
+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text
+/thumbnail.png filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text
+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text
+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text

.potentialpaper/metadata.json added

+++ b/.potentialpaper/metadata.json
@@ -0,0 +1,27 @@
+{
+ "layout": 5,
+ "identifiers": [
+ {
+ "scheme": "openreview",
+ "value": "L4whvxozBR"
+ }
+ ],
+ "title": "Inertia-1: An Open Exploration of Wearable Motion Foundation Models",
+ "authors": [
+ "Zongzhe Xu",
+ "Aakarsh Anand",
+ "Sarah Jiang",
+ "Chuntung Zhuang",
+ "Zitao Shuai",
+ "Sriram Sankararaman",
+ "Yuzhe Yang"
+ ],
+ "abstract": "Wearable motion sensing provides a continuous and scalable window into human behavior and health, making it a natural fit for foundation models, yet its pretraining and scaling principles remain poorly understood. Prior work studies isolated design choices, such as sensor placement or sampling frequency, often under fixed settings and narrow downstream tasks that fail to capture real-world sensing diversity. We introduce Inertia-1, a fully open exploration of wearable motion foundation models. Using massive corpora of accelerometer data from global sources spanning more than 18.2M hours, we build a controlled framework for studying the full lifecycle of wearable motion foundation models, covering data choices such as sensor modality, device placement, sampling rate, window length; model choices such as architectures and model size; and training choices such as pretraining objective and data scale. Extensive evaluations across 15 datasets spanning human activity recognition, freezing-of-gait detection, and disease prediction reveal intriguing findings for building motion foundation models that generalize across tasks and sensing conditions. Collectively, Inertia-1 not only presents state-of-the-art recipes for diverse downstream tasks, but also serves as a comprehensive, practical, and open cookbook for wearable motion representation learning.",
+ "year": 2026,
+ "venue": "NeurIPS 2026",
+ "source": "openreview",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}

community/10-tl-dr.md added

+++ b/community/10-tl-dr.md

community/20-summary.md added

+++ b/community/20-summary.md

community/30-why-it-matters.md added

+++ b/community/30-why-it-matters.md

community/40-critique.md added

+++ b/community/40-critique.md

community/50-errata.md added

+++ b/community/50-errata.md

community/60-reproductions.md added

+++ b/community/60-reproductions.md

community/70-follow-ups.md added

+++ b/community/70-follow-ups.md

owners/10-tl-dr.md added

+++ b/owners/10-tl-dr.md

owners/20-overview.md added

+++ b/owners/20-overview.md

owners/30-results.md added

+++ b/owners/30-results.md

owners/40-demos.md added

+++ b/owners/40-demos.md

owners/50-code-and-data.md added

+++ b/owners/50-code-and-data.md

owners/60-talks.md added

+++ b/owners/60-talks.md

prek.toml added

+++ b/prek.toml
@@ -0,0 +1,36 @@
+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.
+# The site checks every push again; these catch mistakes before you commit. The same on every page.
+
+[[repos]]
+repo = "builtin"
+hooks = [
+ { id = "check-json" },
+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },
+ { id = "end-of-file-fixer", exclude = '^demos/' },
+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },
+ { id = "check-case-conflict" },
+ { id = "check-illegal-windows-names" },
+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },
+]
+
+# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).
+[[repos]]
+repo = "https://github.com/python-jsonschema/check-jsonschema"
+rev = "0.39.0"
+hooks = [
+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },
+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },
+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },
+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },
+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },
+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },
+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },
+]
+
+# Sections formatted the way the web editor formats them.
+[[repos]]
+repo = "https://github.com/rbubley/mirrors-prettier"
+rev = "v3.9.9"
+hooks = [
+ { id = "prettier", files = '^(owners|community)/.*\.md$' },
+]

reviews/openreview/l4whvxozbr/forms.json added

+++ b/reviews/openreview/l4whvxozbr/forms.json
@@ -0,0 +1,227 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ },
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "quality",
+ "clarity",
+ "significance",
+ "originality"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 6
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 5
+ },
+ {
+ "key": "quality",
+ "label": "Quality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "clarity",
+ "label": "Clarity",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "significance",
+ "label": "Significance",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "originality",
+ "label": "Originality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "contribution_type",
+ "label": "Contribution type",
+ "type": "choice"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "strengths_and_weaknesses",
+ "label": "Strengths and weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions",
+ "label": "Questions",
+ "type": "text"
+ },
+ {
+ "key": "limitations",
+ "label": "Limitations",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ },
+ {
+ "key": "paper_formatting_concerns",
+ "label": "Formatting concerns",
+ "type": "text"
+ },
+ {
+ "key": "ethical_concerns",
+ "label": "Ethical concerns",
+ "type": "choice"
+ },
+ {
+ "key": "code_of_conduct_acknowledgement",
+ "label": "Code of conduct",
+ "hidden": true
+ },
+ {
+ "key": "responsible_reviewing_acknowledgement",
+ "label": "Responsible reviewing",
+ "hidden": true
+ }
+ ]
+ },
+ "Rebuttal": {
+ "label": "Rebuttal",
+ "fields": [
+ {
+ "key": "rebuttal",
+ "label": "Rebuttal",
+ "type": "text"
+ }
+ ]
+ },
+ "Ethics_Review": {
+ "label": "Ethics review",
+ "fields": [
+ {
+ "key": "scope_of_ethics_concerns",
+ "label": "Scope",
+ "type": "choice"
+ },
+ {
+ "key": "ethics_review",
+ "label": "Ethics review",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/l4whvxozbr/notes/ehwua7vpfz.json added

+++ b/reviews/openreview/l4whvxozbr/notes/ehwua7vpfz.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "ehwuA7VPfz",
+ "replyTo": "JHZeUIjKKv",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "Thank you for your detailed feedback. We respectfully believe this assessment overlooks several central contributions of the paper and places disproportionate emphasis on one high-level result. We clarify the scope, novelty, and primary findings of the work point by point below:\n\n \n> *Weakness - paragraphs 1 & 2: … limitations of the novelty for this study …this is a well-established finding, the wearable/time-series community has been converging on the same conclusion since roughly 2022*\n\nWe first want to address the reviewer’s comments regarding the novelty of this work. We would like to note that the originality of this work is consistent with NeurIPS's own stated originality criteria in the reviewing guidelines. The General track's Originality criterion is explicit in that \n\n***“originality does not necessarily require introducing an entirely new method. Rather, a work that provides novel insights by evaluating existing methods, or demonstrates improved efficiency, fairness, etc. is also equally valuable.”***\n\nAdditionally, the Significance criterion similarly is evaluated as:\n\n***“unique conclusions about existing data, or a unique theoretical or experimental approach.”***\n\nBy these criteria, we believe Inertia-1's unification of a fragmented experimental space, and the conclusions that unification makes possible, fall exactly within the type of contribution recognized by these criteria.\n\nAdditionally, while we agree that SSL-beats-supervised-from-scratch is well established outside wearable sensing, we would like to clarify that this is not the paper's central contribution. We believe the review's framing conflates one confirmatory result with the paper's actual claims. The inclusion of the SSL and supervised methods comparison is used to validate that our experimental framework behaves as expected, that pretraining was successful, before we use it to evaluate the questions the paper is actually about. The paper's main claims, which we don't believe are addressed in the review, are: \n\n1. How the benefit of self-supervision itself shifts across task families from activity recognition through gait to disease prediction (**Section 4.1**),\n2. How these effects interact with data and modal scaling (**Section 4.2**),\n3. The influence of design and preprocessing choices in training (**Section 4.3**),\n4. Generalization across body placements and complementary gains from multiple sensor streams (**Section 4.4**). \n\nTo the best of our knowledge, none of these are established findings in NLP, vision, or the wearable/time-series literature; each requires the kind of controlled, cross-cutting comparison that no single prior wearable motion study has run. We certainly welcome any concrete suggestions from the reviewer on prior studies to compare with. \n\nTo summarize, we believe the review reflects several misunderstandings regarding the paper’s contribution, scope, and positioning. The review’s novelty assessment centers primarily on one confirmatory finding while not engaging with the paper’s main contributions; we therefore respectfully believe that the reviewer’s assessment of limited novelty is not supported by the specific arguments provided in the review.\n\n \n\n> *Weakness - paragraphs 3: the 18.2M hours figure is an aggregation of existing public datasets, not a newly collected corpus …*\n\nAdditionally, we appreciate the reviewer’s comments regarding the data corpus and how it is presented in this work. We would like to respectfully identify specific instances in the text in which we address this, including: \n\n1. ***Abstract:*** data are drawn from “global sources” and evaluated “across 15 datasets.”\n2. ***Introduction, lines 56–58:*** “we **aggregate** … 18.2M hours of motion data from more than 115,000 people and 15 datasets.”\n3. ***Section 3, lines 115–117:*** Inertia-1 “**aggregates 15 datasets** across 3 task families and 18 downstream tasks.” \nAccordingly, we do not present the creation of a new dataset as a contribution. Our contribution is the *harmonization of existing datasets into a controlled and comparable framework* spanning diverse tasks, sensing configurations, and modeling choices. To avoid any remaining ambiguity, we will revise the wording to make this distinction even more explicit and prevent the scale of the aggregated corpus from being interpreted as a new data-collection claim.\n\n \n\n> *Question: … consider submitting this manuscript to a journal … it's more about pulling things together and measuring them than actually introducing something new … more as a large-scale benchmarking or survey effort than a novel methodological contribution.*\n\nLastly, regarding the reviewer’s suggestion to submit this work to a journal rather than NeurIPS, while we appreciate the suggestion, we respectfully disagree and clarify below both the scope of our contribution and its fit within NeurIPS.\n\n**Scope of Contribution.** Inertia-1 is not a survey or a simple aggregation of prior results. Our work *(1) unifies 15 heterogeneous wearable motion datasets under a controlled training and evaluation framework, (2) systematically compares representative pretraining objectives across HAR, FoG, and disease prediction, (3) characterizes how sampling rate, window length, axis representation, input domain, model scale, and data scale affect transfer, and (4) studies generalization across body placements and sensor modalities, including the complementary benefits of multi-stream sensing.* These conclusions require training and evaluating more than 1,000 models under matched protocols and cannot be obtained by summarizing the existing fragmented literature.\n\n**Nature of Novelty.** The paper does not claim novelty from introducing a new pretraining objective. Its novelty lies in the experimental framework and the **previously unavailable conclusions** enabled by it. In particular, we show that objective differences widen substantially beyond standard HAR, that increasing data diversity is more reliable than increasing model size alone, that sensing choices have task-dependent effects, and that wrist-accelerometer pretraining transfers across placements and sensor types. We therefore respectfully disagree with the characterization that the work merely “pulls things together and measures them.”\n\n**Precedent at NeurIPS.** NeurIPS has clear precedent for systematic empirical studies whose primary contribution is to characterize existing methods, disentangle previously conflated design choices, and derive new conclusions through controlled experimentation [1] [2] [3][4]. These works demonstrate that a contribution need not introduce a new learning objective or architecture when its experimental design enables insightful new understanding. We believe Inertia-1 fits this contribution style by unifying previously fragmented wearable-motion settings and deriving findings that individual prior studies could not establish.\n\n\nReferences:\n1. Subramanian, Shashank, et al. \"Towards foundation models for scientific machine learning: Characterizing scaling and transfer behavior.\" NeurIPS 2023.\n2. Ben-Shaul, Ido, et al. \"Reverse engineering self-supervised learning.\" NeurIPS 2023.\n3. Kazemnejad, Amirhossein, et al. \"The impact of positional encoding on length generalization in transformers.\" NeurIPS 2023.\n4. Park, Seohong, et al. \"Is value learning really the main bottleneck in offline RL?.\" NeurIPS 2024.\n\n \n\n---\nWe sincerely thank the reviewer once again for their time and constructive feedback. To support the community and enable future research, we remain committed to fully open-sourcing our research. We hope our detailed responses and the additional experiments have addressed all of your concerns, and we would be happy to answer any remaining questions during the discussion period. We would be very grateful if you might consider raising your score and championing the paper in light of these updates."
+ },
+ "createdAt": "2026-07-28T12:07:49.058Z",
+ "modifiedAt": "2026-11-18T17:13:13.172Z",
+ "url": "https://openreview.net/forum?id=L4whvxozBR&noteId=ehwuA7VPfz",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/l4whvxozbr/notes/j9lk8ouk31.json added

+++ b/reviews/openreview/l4whvxozbr/notes/j9lk8ouk31.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "J9lk8OUk31",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer BMQ7",
+ "content": {
+ "summary": "In this paper, the authors conduct an open exploration of wearable motion foundation models across multiple large-scale datasets. They show that self-supervised pretraining generally improves transfer performance, but no single objective works best for all tasks. They also find that data representation, temporal resolution, sensor placement, and pretraining scale are as important as model architecture.",
+ "contribution_type": "use_inspired",
+ "strengths_and_weaknesses": "Strengths:\n\nFirst, the authors conduct an open exploration of wearable motion foundation models across multiple large-scale datasets. \n\nSecond, based on extensive experimental results, the authors provide useful insights into wearable motion foundation models, including the impact of pretraining objectives, data representation, temporal resolution, sensor placement, and pretraining scale.\n\nWeaknesses:\n\nFirst, the authors should more clearly discuss the differences between this work and existing state-of-the-art wearable motion foundation models. Although the authors claim that prior motion FM studies often focus on a single objective, or task setting, the paper should provide a more detailed comparison to clarify the unique scope and contribution of this work.\n\nSecond, the technical novelty of this paper appears limited. The main contribution is the experimental exploration and the insights derived from the results, rather than the development of new pretraining methods or fine-tuning strategies. The authors should better position the paper as an empirical study and clarify the novelty beyond benchmarking.\n\nThird, the experimental analysis should be further strengthened. For example, the authors should also report system-level or inference performance, including latency, memory usage, and computational cost, especially for wearable device deployment. In addition, the authors should include more self-supervised learning methods such as LIMU-IMU for IMU sensing in the comparison to better demonstrate the comprehensiveness of the study.\n\nXu, Huatao, Pengfei Zhou, Rui Tan, Mo Li, and Guobin Shen. \"Limu-bert: Unleashing the potential of unlabeled data for imu sensing applications.\" In Proceedings of the 19th ACM Conference on Embedded Networked Sensor Systems, pp. 220-233. 2021.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 2,
+ "originality": 2,
+ "questions": "First, the authors should more clearly distinguish this work from existing state-of-the-art wearable motion foundation models. \n\nSecond, the authors should better clarify the technical novelty of the paper. The current contribution appears to mainly come from large-scale empirical analysis and new insights rather than new pretraining or fine-tuning methods. The authors should explicitly position the paper as a comprehensive empirical study and explain why the findings are significant for the wearable motion learning community. \n\nThird, the authors should strengthen the experimental analysis by reporting system-level performance, including inference latency, memory usage, model size, and computational cost. Since wearable motion foundation models may be deployed on mobile or edge devices, these metrics are important for understanding practical feasibility. Such analysis would help answer whether the studied models are suitable for real-world wearable applications. \n\nFourth, the authors should include more representative self-supervised learning methods for IMU or wearable sensing in the comparison. This would help assess whether the conclusions about pretraining objectives are robust across a broader set of baselines.",
+ "limitations": "Yes",
+ "rating": 4,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "There are no paper formatting concerns.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "Most of my concerns have been addressed. However, the novelty of the proposed method is still limited."
+ },
+ "createdAt": "2026-06-25T23:38:00.999Z",
+ "modifiedAt": "2026-11-18T13:37:40.582Z",
+ "url": "https://openreview.net/forum?id=L4whvxozBR&noteId=J9lk8OUk31",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/l4whvxozbr/notes/jhzeuijkkv.json added

+++ b/reviews/openreview/l4whvxozbr/notes/jhzeuijkkv.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "JHZeUIjKKv",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer Yzzk",
+ "content": {
+ "summary": "This manuscript provided a review to foundation models for wearable motion sensing. Systematically examines how data, model, and training choices, such as sensor placement, sampling rate, architecture, pretraining objective, and scale. This study also evaluated across 15 datasets covering activity recognition, freezing-of-gait detection, and disease prediction, it delivers state-of-the-art results and practical guidance for building generalizable wearable motion representations.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "This manuscript explored how pre-training objectives, sensing configurations, scale, and downstream tasks jointly shape transferable motion representations. The authors put together large amount of wearable motion data including multiple datasets. According to those comparisons of SSL models and supervised baselines across HAR dataset, FoG tasks, and disease prediction tasks, this study summarized the finding of self-supervised pretraining consistently outperforms supervised training from scratch across task categories, and the result suggests strong representations learned from unlabeled population cohorts regardless of the specific downstream application. However, this is a well-established finding, the wearable/time-series community has been converging on the same conclusion since roughly 2022. The claimed finding mirrors the established narrative from NLP(BERT, GPT) and vision (MAE, SimCLR, MoCo), where SSL on large unlabeled corpora (e.g., 18M+ hours) consistently beats supervised-from-scratch on limited labeled data. \n\nThere are limitations of the novelty for this study. For example, as conclusion (line 383-385) mentioned, \"we find that self-supervised pretraining consistently improves transfer over supervised training from scratch, but no single objective dominates across all task families\". For the first half of this conclusion, SSL improves over supervised from scratch, a well established and discussed topic. It's not a contribution on this manuscript. I agree with that the second half of this conclusion has modest novelty but not entirely surprising, because the time-series and vision SSL communities have observed this for a while, e.g., SimCLR, MoCo these contrastive methods tend to favor discrimination tasks and BERT-style masked reconstruction tends to favor dense/generative understanding. \n\nIn addition, the 18.2M hours figure is an aggregation of existing public datasets, not a newly collected corpus, this should be stated more clearly upfront rather than presented in a way that implies data collection as a contribution. The abstract's phrasing does technically acknowledge this, but the overall framing still gives the impression of a data contribution. The real contributions are the controlled experimental framework and the empirical findings",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 2,
+ "originality": 3,
+ "questions": "The suggestion is consider to submit this manuscript to a journal might be more competitive. The work is solid and carefully done, as authors mentioned at the end, it's a comprehensive cookbook for wearable motion representation learning, but at its core it's more about pulling things together and measuring them than actually introducing something new. The \"Inertia-1\" branding and \"fully open exploration\" framing somewhat overstate the novelty. The core deliverable, a systematic sweep of design choices across existing datasets and architectures, reads more as a large-scale benchmarking or survey effort than a novel methodological contribution.",
+ "limitations": "Yes.",
+ "rating": 3,
+ "confidence": 5,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "No.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "Based on the authors' responses, I am raising my score to 3, as a borderline rating, and adjusting my originality assessment upward accordingly. My remaining hesitation is about significance rather than technical soundness, and I will follow the discussion with the other reviewers and the AC with an open mind."
+ },
+ "createdAt": "2026-06-18T21:53:30.620Z",
+ "modifiedAt": "2026-11-18T13:37:42.870Z",
+ "url": "https://openreview.net/forum?id=L4whvxozBR&noteId=JHZeUIjKKv",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/l4whvxozbr/notes/jwkxzqd58c.json added

+++ b/reviews/openreview/l4whvxozbr/notes/jwkxzqd58c.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "JwkXZQD58c",
+ "replyTo": "P0ysIVlgDQ",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "We thank the reviewer for their constructive feedback and positive evaluation of our work. We sincerely appreciate your recognition of the clarity, relevance, and comprehensiveness of our exploration. We hope the detailed responses below address your concerns.\n\n&nbsp;\n> *Q1: … Including an aggregate statistic …*\n\nWe originally emphasized per-dataset results because aggregate metrics can obscure task-specific variation. However, we agree that an overall summary improves readability and report average performance and rank below.\n\n||HAR AUC|FoG AUC|Disease AUC|Avg. Rank|\n|---|---|---|---|---|\n|ViT|92.03|71.70|48.10|7.64|\n|CNN|91.87|73.10|56.16|6.96|\n|PatchTST|**95.84**|82.03|63.64|**3.93**|\n|AR-Transformer|*95.21*|77.70|*68.82*|*3.98*|\n|AR-GRU|94.73|82.67|64.70|4.61|\n|DINO|89.92|77.93|68.82|5.17|\n|SimCLR|90.43|*84.30*|67.20|4.53|\n|SSL-Wearables|87.89|75.00|**68.84**|6.04|\n|RelCon|93.31|**86.23**|61.74|5.46|\n|SelfPAB|93.22|75.97|59.14|6.68|\n\nThe aggregate results remain strongly task-dependent. PatchTST and AR-Transformer lead on HAR, RelCon on FoG, and SSL-Wearables and AR-Transformer on disease prediction. We believe these results further support our claim in the paper that **no single pretraining objective performs uniformly best across all downstream task families.**\n\n&nbsp;\n\n> *W2: … recommendations are presented without … rationale…*\n\nWe deeply agree with the reviewer that the recommendations would benefit from mechanistic explanations. Below we give two such analyses, and we remain happy to address any remaining concerns that the reviewer might have during the discussion period.\n\n**(i) Low-rate HAR robustness** \n\nUsing WISDM, we compare AR-Transformer pretrained at 20 Hz and 1 Hz. We report activity intensity quantified by gravity-removed acceleration power [1] and AUROC stratified by different levels of activity intensity.\n\n|activity group|intensity|AUROC 20 Hz|AUROC 1 Hz|(1−20 Hz)|\n|---|---|---|---|---|\n|static (sitting, standing, typing, writing)|3.3–4.4|92.6|93.2|**+0.7**|\n|hand/eating (6 activities)|4.6–74|89.8|87.3|−2.5|\n|high-cadence (6 activities)|25–478|95.6|92.8|−2.8|\n|locomotion (walking, stairs)|116–160|97.4|94.0|−3.4|\n|**macro (all 18 activities)**|**93.2**|**91.2**|**−2.0**|\n\nOnly near-stationary activities improve at 1 Hz, and the gain from 1 Hz to 20 Hz increases with activity intensity. Even for more dynamic activities, however, the reduction is only 2.5–3.4 AUROC points. This explains why aggregate HAR remains competitive after aggressive downsampling: posture-driven classes require little high-frequency information, while dynamic classes retain substantial discriminative signals.\n\n**(ii) Short-event FoG sensitivity** \n\nSection 4.3 attributes the stronger FoG performance of time-domain models to their preservation of precise temporal structure. We now provide a quantitative mechanism on the FoGTurning dataset. Spectrogram methods impose a fixed temporal granularity through their FFT window and hop size. For 30 s inputs, Self-PAB uses 3.2 s frames and averages them into the final embedding. While the median episode lasts 3.0 s, more than half of the events are shorter than one frame and may be blended with surrounding gait. We therefore expect Self-PAB to perform worst on episodes below 3.2 s.\nWe hold evaluation fixed across encoders: identical 30 s, 20 Hz triaxial inputs, frozen backbones, linear probes, and subject-grouped folds. Duration bins follow Self-PAB’s 3.2 s frame length.\n\n|Encoder|domain|overall|episode <3.2 s|3.2–6.4 s|6.4–15 s|>15 s|\n|---|---|---|---|---|---|---|\n|Self-PAB|time-frequency|0.705|**0.356**|0.537|0.733|0.781|\n|ART|time|0.918|0.854|0.834|0.831|0.981|\n|PatchTST|time|0.923|0.820|0.814|0.900|0.977|\n|ARG|time|0.908|0.821|0.841|0.803|0.975|\n|*positive windows*||*1687*|*76*|*328*|*331*|*952*|\n\nSelf-PAB’s AUROC increases monotonically with episode duration, from 0.356 for events shorter than one frame to 0.781 for events longer than 15 s, whereas the time-domain encoders remain strong across all bins. This directly supports our claim that time-domain modeling better preserves brief, transient FoG patterns. The fixed spectrogram granularity disproportionately weakens short events by mixing them with adjacent gait, while time-domain models retain these local signatures more effectively. Self-PAB remains weaker even for longer episodes, so frame length does not explain the entire gap, but it provides a clear mechanism for the pronounced deficit on short FoG events.\n\n&nbsp;\n\n> *Q3: … relate these choices to common wearable hardware … or prior literature…*\n\nWe use 20 Hz as a practical high-resolution reference: prior work shows that most wearable-motion energy lies below 10 Hz and that reducing 100 Hz signals to approximately 20 Hz substantially lowers storage and computation with minimal performance loss [2]. We use 1 Hz to represent per-second actigraphy summaries and 5 Hz as an intermediate low-power regime [6]. Prior work shows that sampling rate materially affects computation and power in continuous recognition [3,7], motivating evaluation between summary-level and full-resolution sensing.\n\n&nbsp;\n\n> *W1&Q2: … why certain … pretraining strategies outperform others.*\n\nWe agree that discussing why general-purpose SSL methods often outperform wearable-specific objectives would strengthen the practical takeaways. While our results do not establish a definitive cause, two factors may contribute: general-purpose methods often benefit from mature architectures and optimization recipes, whereas wearable-specific objectives may encode assumptions tailored to particular sampling rates, windows, or sensing configurations that **transfer less robustly** across heterogeneous settings.\nWe emphasize that our comparison evaluates robustness under a shared protocol, not each method’s task-specific optimum. Because wearable-specific methods often use different input lengths, sampling rates, channel configurations, and tuning procedures, reproducing every original setting would undermine a controlled comparison. We therefore match the main training choices and interpret the results as evidence of transfer under common settings, not universal superiority.\n\n&nbsp;\n\n> *W3: … paper does not report confidence intervals …*\n\nWe fully agree that statistical uncertainty would strengthen the paper. We bootstrap the test set and aggregate across target datasets. Given space constraints, we report analyses for the central claims below and will be happy to provide additional comparisons during discussion.\n\n**HAR AUC with 95% CI**\n\n||A|A_ci|B|B_ci|p|\n|---|---|---|---|---|---|\n|Higher Sampling Rate|ART @ 20 Hz|[95.2-95.4]|ART @ 1 Hz|[91.2-91.4]|<0.01|\n|-|ART @ 20 Hz|[95.2-95.4]|ART @ 5 Hz|[93.4-93.7]|<0.01|\n|-|ART @ 5 Hz|[93.4-93.7]|ART @ 1 Hz|[91.2-91.4]|<0.01|\n|Window Length Effects|ART @ 30 s|[95.2-95.4]|ART @ 10 s|[92.6-92.8]|<0.01|\n|-|ART @ 30 s|[95.2-95.4]|ART @ 60 s|[90.2-90.4]|<0.01|\n|Triaxial vs. Uniaxial|ART triaxial|[95.2-95.4]|ART uniaxial|[91.3-91.5]|<0.01|\n|SSL vs. Supervised|ART|[95.1-95.3]|CNN|[91.8-92.1]|<0.01|\n\n**FOG AUC with 95% CI**\n\n||A|A_ci|B|B_ci|p|\n|---|---|---|---|---|---|\n|Higher Sampling Rate|ART @ 20 Hz|[78.4-81.6]|ART @ 1 Hz|[66.9-70.7]|<0.01|\n|-|ART @ 20 Hz|[78.4-81.6]|ART @ 5 Hz|[80.5-83.4]|0.085|\n|-|ART @ 5 Hz|[80.5-83.4]|ART @ 1 Hz|[66.9-70.7]|<0.01|\n|Window Length Effects|ART @ 30 s|[78.4-81.6]|ART @ 10 s|[78.9-82.0]|0.680|\n|-|ART @ 30 s|[78.4-81.6]|ART @ 60 s|[86.2-89.9]|<0.01|\n|Triaxial vs. Uniaxial|ART triaxial|[78.4-81.6]|ART uniaxial|[76.4-79.8]|0.043|\n|SSL vs. Supervised|ART|[76.0-79.4]|CNN|[71.4-74.7]|<0.01|\n\n**Disease AUC with 95% CI**\n\n||A|A_ci|B|B_ci|p|\n|---|---|---|---|---|---|\n|Higher Sampling Rate|ART @ 20 Hz|[61.6-76.0]|ART @ 1 Hz|[51.0-62.0]|0.012|\n|-|ART @ 20 Hz|[61.6-76.0]|ART @ 5 Hz|[50.3-58.5]|<0.01|\n|Window length effects|ART @ 30 s|[61.6-76.0]|ART @ 10 s|[58.8-67.5]|0.213|\n|-|ART @ 30 s|[61.6-76.0]|ART @ 60 s|[55.2-69.3]|0.222|\n|Triaxial vs. Uniaxial|ART triaxial|[61.6-76.0]|ART uniaxial|[64.1-71.3]|0.756|\n|SSL vs. Supervised|ART|[61.6-76.0]|CNN|[50.7-56.8]|<0.01|\n\nThe analyses support most central claims. For HAR, performance increases significantly with sampling frequency. The effect of window length is task-dependent: HAR peaks at 30s, whereas FoG only improves significantly from 30s to 60s. Disease prediction shows no significant window-length differences. Triaxial input significantly improves HAR and FoG but not disease prediction; we will revise this claim to state that triaxial input benefits most evaluated task families.\nWe thank the reviewer for drawing attention to the FoG result at 5 Hz. As shown in the table, performance at 5 Hz is numerically above 20 Hz but not significantly different, indicating a plateau at 5 Hz and above rather than a meaningful advantage. We will add confidence intervals and clarify this interpretation.\n\n&nbsp;\n\n> *Q4: Renaming*\n\nWe appreciate this suggestion and the meticulous reading and will rename the sections accordingly.\n\n&nbsp;\n---\nReferences:\n1. Bao, et al. Activity recognition from user-annotated acceleration data. 2004.\n2. Yamane, et al. Effects of sampling frequency on human activity 2025.\n3. Yan, et al. Energy-efficient continuous activity recognition.. 2012.\n4. Moore, et al. Ambulatory monitoring of freezing of gait in Parkinson's disease. 2008.\n5. Bächlin et al. Wearable assistant for Parkinson's disease patients.. 2010.\n6. Yamane, et al. Effects of sampling frequency on human activity recognition.. 2025.\n7. Bieber, et al. Low sampling rate for physical activity recognition. 2014.\n\n&nbsp;\n---\nWe sincerely thank the reviewer again for their time and constructive feedback. We remain committed to fully open-sourcing this work and hope our responses and additional experiments have addressed your concerns. We would be happy to answer any remaining questions during the discussion period and would be very grateful if you might consider raising your score and championing the paper in light of these updates."
+ },
+ "createdAt": "2026-07-28T11:55:05.259Z",
+ "modifiedAt": "2026-11-18T17:13:13.694Z",
+ "url": "https://openreview.net/forum?id=L4whvxozBR&noteId=JwkXZQD58c",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/l4whvxozbr/notes/nt7dqxvytg.json added

+++ b/reviews/openreview/l4whvxozbr/notes/nt7dqxvytg.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "Nt7DqxvYTG",
+ "replyTo": "J9lk8OUk31",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "Thank you for your thoughtful and thorough feedback. We appreciate your recognition of the breadth of our study and the insights it provides. We address each of your concerns and questions below and hope these clarifications better convey the paper’s contributions and merit a favorable reassessment.\n\n&nbsp;\n> *W1&Q1: … more clearly discuss the differences between this work and existing state-of-the-art wearable motion foundation models …*\n\nThank you for your comment regarding clarifying the positioning of previous wearable foundation models vs. our work. We would like to clarify that Inertia-1 does not aim to build the strongest wearable motion foundation model. Rather, our goal is to unify a research space that has, until now, been fragmented across datasets, sensor configurations, and objectives that were never designed to be compared against one another (*Table 1* summarizes how prior studies each only cover a subset of the design choices we evaluate, whether that is sensors, placements, tasks, or configurations). Each prior wearable motion foundation model was built and validated within a single dataset, sensor configuration, or objective, offering no controlled view of how these choices interact. \n\nIn contrast, Inertia-1 evaluates 10 pretraining objectives under a shared protocol across a grid of experimental axes (sampling rate, window size, sensor modality, body placement -- *Section 3.3, Table 7*). This experimental setup allows us to isolate the effect of each individual design choice and glean insights systematically, as summarized in Section 4.3. Inertia-1’s contributions to this research space includes the following insights: we demonstrate that transferability across body placements and cooperation across multiple sensor streams can be measured (demonstrated via *Section 4.4, see Figures 7 & 8*). Thus, we position Inertia-1’s contribution as this unified, controlled empirical study to surface actionable insights for the wearable research community, rather than positing a new singular wearable foundation model. \n\n&nbsp;\n\n> *W2&Q2: … the authors should better clarify the technical novelty of the paper … clarify the novelty beyond benchmarking*\n\nWe appreciate the reviewer’s comments regarding better positioning the paper, and making clear the novelty beyond benchmarking model architectures. To clarify, we are **not** presenting a new training methods paper, rather, we present the first controlled, cross-objective, cross-task-family study of design choices for wearable motion foundation models at this scale, yielding *practical findings that no prior study has produced*. Under the NeurIPS guidelines, originality and significance of work is defined as\n\n***“not necessarily [requiring] introducing an entirely new method. Rather, a work that provides novel insights by evaluating existing methods, or demonstrates improved efficiency, fairness, etc. is also equally valuable.”***\n\nUnder this criteria, we feel that Inertia-1 provides such a contribution: a unified experimental framework (*Section 3, Table 7*) that turns previously incomparable and isolated findings into a singular body of evidence in wearable motion representations.\n\nSpecifically, these findings include: **(1) generalization across body placements, (2) cooperative gains from multiple sensor streams (Section 4.4), (3) how the benefit of self-supervision itself shifts across task families from activity recognition through gait to disease prediction (Section 4.1), and (4) how these results shift with scaling (Section 4.2)**. None of these findings follow from SSL-beats-supervised alone, and none of them are visible from any single prior study in isolation (*Table 1*). We will revise the abstract, introduction, and conclusion to lead explicitly with this framing so the contribution reads as what it is, rather than a new method. Prior work has largely centered on \"which architecture or objective is best?\" in isolation; our results show that the answer depends jointly on task granularity, sensing configuration, and data scale (Section 4.3), meaning a recipe validated on one placement, sensor, or task family cannot be assumed to transfer to another. This has immediate practical consequences for deployment: practitioners building wearable systems for a new placement, sensor suite, or clinical task can use these findings to anticipate which design choices will matter most, rather than re-running an isolated ablation from scratch on their own limited data.\n\nAdditionally, large‑scale physical activity surveillance and many contemporary HAR datasets rely primarily on wrist‑worn triaxial accelerometer data, while multimodal or multi‑placement datasets remain comparatively small and specialized [1][2][3]. Many other datasets might contain other body placements, sensors, or configurations, but are often too small to support pretraining (Section 1, Table 1). Our model is the first to study the transferability of pretraining on these large wrist-worn accelerometer corpora, and the downstream advantages such transfer poses for health related prediction tasks. \n\n&nbsp;\n\n> *W3&Q3: … strengthen the experimental analysis by reporting system-level performance … whether the studied models are suitable for real-world wearable applications*\n\nWhile we note that the focus of our paper is not real time deployment, we provide some insights into the system-level performance of some of our models here. The encoder used throughout is our default configuration, 8.4 M trainable parameters. Measured on one A100-SXM4-40GB in fp32, encoder only, in eval mode: a single 30 s window costs **1.04 GFLOPs at 20 Hz** and **0.25 GFLOPs at 1 Hz**. Peak VRAM for a batch of 64 windows is **0.13 GB at 20 Hz** and **0.07 GB at 1 Hz**, and latency for that batch is **5.8 ms at 20 Hz** against **2.0 ms at 1 Hz** — 11.1 k versus 31.3 k windows per second, so roughly 2.8x more throughput. PatchTST is within a few percent of ART on all of these at matched\ninput length. Critically, the processing time for a 30s window is a small fraction of the actual duration of the window. We see this as a benefit for any foundation models applied in realtime contexts as it demonstrates their ability to constantly process large amounts of data and provide valuable insights on the signal.\n\n&nbsp;\n\n> *W4 & Q4: … include more representative self-supervised learning methods for IMU or wearable sensing in the comparison.*\n\nWe thank the reviewer for this valuable suggestion. We **have already implemented and begun pretraining** two additional well-established wearable sensing methods, LIMU-BERT [4] and LSM-2 [5]. To ensure a fair comparison with the existing baselines, each method must be pretrained under the same data and compute settings, which requires approximately two days on four GPUs. We will report the results as soon as the runs are completed during the discussion period and update the manuscript accordingly.\n\n&nbsp;\n---\nReferences:\n1. Yuan, Hang, et al. \"Self-supervised learning for human activity recognition using 700,000 person-days of wearable data.\" NPJ digital medicine 7.1 (2024): 91.\n2. Doherty, Aiden, et al. \"Large scale population assessment of physical activity using wrist worn accelerometers: the UK biobank study.\" PloS one 12.2 (2017): e0169649.\n3. Mannini, Andrea, et al. \"Activity recognition using a single accelerometer placed at the wrist or ankle.\" Medicine and science in sports and exercise 45.11 (2013): 2193.\n4. Xu, Huatao, et al. \"Limu-bert: Unleashing the potential of unlabeled data for imu sensing applications.\" Proceedings of the 19th ACM Conference on Embedded Networked Sensor Systems. 2021.\n5. Xu, Maxwell A., et al. \"Lsm-2: Learning from incomplete wearable sensor data.\" arXiv preprint arXiv:2506.05321 (2025).\n\n&nbsp;\n---\nWe sincerely thank the reviewer once again for their time and constructive feedback. To support the community and enable future research, we remain committed to fully open-sourcing our research. We hope our detailed responses and the additional experiments have addressed your concerns, and we would be happy to answer remaining questions during the discussion period. We would be very grateful if you might consider raising your score and championing the paper in light of these updates."
+ },
+ "createdAt": "2026-07-28T12:03:22.482Z",
+ "modifiedAt": "2026-11-18T17:13:12.355Z",
+ "url": "https://openreview.net/forum?id=L4whvxozBR&noteId=Nt7DqxvYTG",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/l4whvxozbr/notes/p0ysivlgdq.json added

+++ b/reviews/openreview/l4whvxozbr/notes/p0ysivlgdq.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "P0ysIVlgDQ",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer Cr43",
+ "content": {
+ "summary": "This paper presents a comprehensive empirical study of foundation models for wearable motion sensing. The authors compare supervised and self-supervised pretraining strategies using large-scale wearable datasets, evaluating both general-purpose self-supervised methods and wearable-specific approaches. The pretrained models are assessed on 10 downstream datasets spanning human activity recognition (HAR), freezing-of-gait (FoG) detection, and disease prediction tasks, providing a broad evaluation of transferability. The paper also investigates several practical design choices, including model scaling, pretraining dataset size, signal duration, accelerometer sampling frequency, the addition of other signals and different sensor placements. Rather than proposing a new learning method, the paper aims to provide a set of empirical findings and practical recommendations for developing wearable motion foundation models.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "**Strengths**\n- The paper addresses a relevant topic as foundation models for wearable sensing continue to gain interest\n- The experimental evaluation is comprehensive, covering numerous pretraining methods, downstream tasks, and practical design choices\n- Evaluating transfer performance on ten downstream datasets demonstrates good generalizability beyond the pretraining datasets\n- The comparison between learning objectives provides useful insights, showing that no single approach consistently dominates across all tasks\n- The manuscript is clearly written, well structured, and easy to follow despite the large number of experiments\n\n**Weaknesses**\n- The work is primarily an empirical benchmark, and while the reported trends are convincing, the discussion could provide more insight into why certain design choices or pretraining strategies outperform others\n- Some practical recommendations are presented without substantial discussion of the underlying rationale, leaving readers with empirical observations rather than explanatory insights\n- Many conclusions are based on differences in AUROC across downstream tasks, but the paper does not report confidence intervals, statistical significance tests, or variability across multiple training runs. Given that several reported improvements appear modest, some estimate of statistical uncertainty would help readers assess whether observed differences are meaningful.",
+ "quality": 4,
+ "clarity": 4,
+ "significance": 3,
+ "originality": 3,
+ "questions": "- Table 3 presents results across many HAR datasets, making it difficult to identify the strongest overall model. Including an aggregate statistic, such as the mean AUROC or average rank across datasets, would improve readability and facilitate comparison between methods\n- Since the paper aims to provide practical guidance, a more explicit discussion of why general-purpose self-supervised methods often outperform wearable-specific objectives would strengthen the practical takeaways. Even if no definitive explanation exists, further discussing possible factors would help readers interpret the results.\n- In the experiments evaluating accelerometer sampling frequencies, the authors compare 1, 5, and 20 Hz. While these results are interesting, the motivation for selecting these specific frequencies is not entirely clear. It would be helpful to relate these choices to common wearable hardware configurations, battery constraints, or prior literature. Additionally, the observation that 5 Hz performs particularly well for the FoG task deserves further discussion.\n- Section 4 not only presents experimental results but also interprets them and extracts practical lessons. Renaming this section to \"Results and Discussion\" would be a better match. Similarly, Section 5 could be named Conclusion and Future Work or something similar",
+ "limitations": "While the scaling studies are valuable, the discussion could more explicitly address the practical trade-offs between performance improvements and computational cost. This would help to decide when increasing model size or pretraining data is worth it.",
+ "rating": 5,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "Nothing to report",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "I recommend **Accept**. The authors addressed my main concerns regarding metric reporting and uncertainty quantification, and provided additional analyses and justification for how design choices affect performance."
+ },
+ "createdAt": "2026-06-26T09:18:27.128Z",
+ "modifiedAt": "2026-11-18T13:37:39.181Z",
+ "url": "https://openreview.net/forum?id=L4whvxozBR&noteId=P0ysIVlgDQ",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/l4whvxozbr/notes/vwmi9tihv4.json added

+++ b/reviews/openreview/l4whvxozbr/notes/vwmi9tihv4.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "VWmI9TihV4",
+ "replyTo": null,
+ "kind": "meta_review",
+ "invitation": "Meta_Review",
+ "signature": "Area Chair 7oFj",
+ "content": {
+ "metareview": "Reviewers describe the study as comprehensive and carefully executed. It covers many pretraining objectives, downstream tasks, and design choices. All three found the manuscript clear and well structured despite the number of experiments. Reviewer Cr43 rated both quality and clarity excellent. Reviewers Cr43 and BMQ7 praise the breadth of the evaluation and the practical value of comparing learning objectives across task families.\n\nHowever, Yzzk and BMQ7 question whether the findings amount to a contribution. Yzzk argues that the headline conclusions restate what the wearable and time-series communities converged on several years ago, and what vision and NLP established earlier. Related, BMQ7 asks for an explicit comparison against existing wearable motion foundation models and notes that the paper asserts rather than demonstrates that prior work addresses only isolated design choices. Both reviewers conclude that the work is better characterized as benchmarking than as a methodological advance, and both suggest the framing should be adjusted accordingly. While Yzzk objects that the presentation implies a data contribution where the corpus aggregates existing public datasets, reviewers Cr43 and BMQ7 both note that the practical recommendations arrive without much explanation of why particular choices prevail. This leaves readers with mere observations.\n\nReviewer Cr43 brings up the strongest technical concern despite being most positive: the conclusions rest on AUROC differences reported without confidence intervals, significance tests, or across-run variability, while several of those differences are modest.\n\nIn addition, the benefit of self-supervision seems to grow much from activity recognition through gait to disease prediction. Reduced sampling rate degrades clinical prediction, which is reasonable, but leaves activity recognition unaffected?\n\nFor the response:\n- Statistical uncertainty on the main tables, and a restatement of which conclusions survive it\n- A clear separation of findings that were genuinely not known from those that confirm existing belief\n- Explicit positioning against prior motion foundation models\n- Corrected framing around the corpus and the naming\n\nAfter discussion:\n\nThe rebuttal and discussion addressed the main concerns. The authors added bootstrap confidence intervals and significance tests for the central comparisons. These analyses support most of the main conclusions and led the authors to narrow the triaxial-input claim to most, rather than all, task families. They also added analyses that better explain the sampling-rate and FoG results. This addresses the concern that some recommendations were based mainly on empirical observations without interpretation.\n\nThe remaining disagreement concerns the significance of the contribution. I agree with Reviewers Yzzk and BMQ7 that several individual findings are confirmatory and that the paper's main contribution is empirical rather than methodological. However, the discussion clarified the contribution of the controlled study across task families, sensing choices, scale, placements, and sensor modalities. The added LIMU-BERT and LSM-2 results also strengthen the comparison with prior wearable motion foundation models. Reviewer Cr43 recommends acceptance, Reviewer BMQ7 recommends borderline acceptance, and Reviewer Yzzk raised their score to borderline reject, with the remaining concern focused on significance rather than technical soundness.\n\nI therefore change my recommendation to Accept (poster). The camera-ready should reflect the framing established during discussion: present the work as a large-scale controlled empirical study and experimental framework; clearly distinguish confirmatory findings from the main new findings; state the planned release and license; and include the promised uncertainty reporting and statistical details. The narrowed triaxial-input claim should be retained."
+ },
+ "createdAt": "2026-07-22T19:45:32.375Z",
+ "modifiedAt": "2026-11-18T15:20:12.286Z",
+ "url": "https://openreview.net/forum?id=L4whvxozBR&noteId=VWmI9TihV4",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/l4whvxozbr/notes/yomouzxu1p.json added

+++ b/reviews/openreview/l4whvxozbr/notes/yomouzxu1p.json
@@ -0,0 +1,19 @@
+{
+ "schema": "review/1",
+ "id": "YomoUZxU1P",
+ "replyTo": null,
+ "kind": "decision",
+ "invitation": "Decision",
+ "signature": "Program Chairs",
+ "content": {
+ "title": "Paper Decision",
+ "decision": "Accept (poster)",
+ "comment": "",
+ "metareview": "Reviewers describe the study as comprehensive and carefully executed. It covers many pretraining objectives, downstream tasks, and design choices. All three found the manuscript clear and well structured despite the number of experiments. Reviewer Cr43 rated both quality and clarity excellent. Reviewers Cr43 and BMQ7 praise the breadth of the evaluation and the practical value of comparing learning objectives across task families.\n\nHowever, Yzzk and BMQ7 question whether the findings amount to a contribution. Yzzk argues that the headline conclusions restate what the wearable and time-series communities converged on several years ago, and what vision and NLP established earlier. Related, BMQ7 asks for an explicit comparison against existing wearable motion foundation models and notes that the paper asserts rather than demonstrates that prior work addresses only isolated design choices. Both reviewers conclude that the work is better characterized as benchmarking than as a methodological advance, and both suggest the framing should be adjusted accordingly. While Yzzk objects that the presentation implies a data contribution where the corpus aggregates existing public datasets, reviewers Cr43 and BMQ7 both note that the practical recommendations arrive without much explanation of why particular choices prevail. This leaves readers with mere observations.\n\nReviewer Cr43 brings up the strongest technical concern despite being most positive: the conclusions rest on AUROC differences reported without confidence intervals, significance tests, or across-run variability, while several of those differences are modest.\n\nIn addition, the benefit of self-supervision seems to grow much from activity recognition through gait to disease prediction. Reduced sampling rate degrades clinical prediction, which is reasonable, but leaves activity recognition unaffected?\n\nFor the response:\n- Statistical uncertainty on the main tables, and a restatement of which conclusions survive it\n- A clear separation of findings that were genuinely not known from those that confirm existing belief\n- Explicit positioning against prior motion foundation models\n- Corrected framing around the corpus and the naming\n\nAfter discussion:\n\nThe rebuttal and discussion addressed the main concerns. The authors added bootstrap confidence intervals and significance tests for the central comparisons. These analyses support most of the main conclusions and led the authors to narrow the triaxial-input claim to most, rather than all, task families. They also added analyses that better explain the sampling-rate and FoG results. This addresses the concern that some recommendations were based mainly on empirical observations without interpretation.\n\nThe remaining disagreement concerns the significance of the contribution. I agree with Reviewers Yzzk and BMQ7 that several individual findings are confirmatory and that the paper's main contribution is empirical rather than methodological. However, the discussion clarified the contribution of the controlled study across task families, sensing choices, scale, placements, and sensor modalities. The added LIMU-BERT and LSM-2 results also strengthen the comparison with prior wearable motion foundation models. Reviewer Cr43 recommends acceptance, Reviewer BMQ7 recommends borderline acceptance, and Reviewer Yzzk raised their score to borderline reject, with the remaining concern focused on significance rather than technical soundness.\n\nI therefore change my recommendation to Accept (poster). The camera-ready should reflect the framing established during discussion: present the work as a large-scale controlled empirical study and experimental framework; clearly distinguish confirmatory findings from the main new findings; state the planned release and license; and include the promised uncertainty reporting and statistical details. The narrowed triaxial-input claim should be retained.",
+ "final_justification": "I changed my preliminary recommendation from Reject to Accept after considering the rebuttal and discussion. The authors added uncertainty analysis for the main comparisons, narrowed a claim that was not supported across all task families, added requested wearable-motion baselines, and clarified the paper's empirical framing and planned release. The remaining reviewer concern is mainly about significance rather than technical soundness. I find the controlled analysis across tasks, sensing settings, and transfer conditions sufficiently significant for acceptance. The camera-ready should follow the framing, release, and uncertainty-reporting commitments made during discussion.\n\nThe discussion phase moved this paper up: two reviewers raised their assessments after the response. The most positive reviewer re-confirmed a recommendation to accept after the contribution-type reclassification. The reviewer who remains most reserved raised their assessment to borderline and stated explicitly that their residual hesitation concerns significance rather than technical soundness and that they would follow the discussion with an open mind.\n\nThe authors submitted three confidential comments. Two argued that individual reviewers had misunderstood the scope or contribution of the work. I read and considered all three. The substance of those arguments was also made in the public threads, where the reviewers in question engaged with it directly. One accepted the point about the originality and significance criteria and revised upward as a result. My recommendation is based on the public record and on the strength of the response (not on the confidential\nmessages). I would have reached the same conclusion without them."
+ },
+ "createdAt": "2026-09-24T11:18:52.686Z",
+ "modifiedAt": "2026-11-18T14:53:56.182Z",
+ "url": "https://openreview.net/forum?id=L4whvxozBR&noteId=YomoUZxU1P",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/l4whvxozbr/submission.json added

+++ b/reviews/openreview/l4whvxozbr/submission.json
@@ -0,0 +1,12 @@
+{
+ "schema": "submission/1",
+ "id": "L4whvxozBR",
+ "venue": {
+ "id": "NeurIPS.cc/2026/Conference",
+ "name": "NeurIPS 2026",
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"
+ },
+ "number": 9890,
+ "url": "https://openreview.net/forum?id=L4whvxozBR",
+ "license": "CC-BY-4.0"
+}

versions/v_ytev6fi9.json added

+++ b/versions/v_ytev6fi9.json
@@ -0,0 +1,22 @@
+{
+ "date": "2026-04-30",
+ "kind": "submitted",
+ "label": "NeurIPS 2026",
+ "submissions": [
+ {
+ "venue": "NeurIPS 2026",
+ "status": "accepted",
+ "decision": "Accept (poster)",
+ "number": 9890,
+ "url": "https://openreview.net/forum?id=L4whvxozBR",
+ "reviews": "openreview/l4whvxozbr",
+ "evidence": [
+ "https://openreview.net/forum?id=L4whvxozBR"
+ ]
+ }
+ ],
+ "url": "https://openreview.net/forum?id=L4whvxozBR",
+ "evidence": [
+ "https://openreview.net/forum?id=L4whvxozBR"
+ ]
+}