Augmented Equivariant Mesh Networks for Anatomical Segmentation
Update NeurIPS 2026 submission NHNCBuH2mF: 8 notes
@openreview[bot] · 2026-11-24 15:49 UTC · afa0122ed3f8 ·
reviews/openreview/nhncbuh2mf/notes/8wkmj5r436.json added
+++ b/reviews/openreview/nhncbuh2mf/notes/8wkmj5r436.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "8WkmJ5R436",+ "replyTo": "em4g3OeARs",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer SncY",+ "comment": "Thank you for your review! We also appreciate you recognizing the well-motivated problem, breadth across anatomical settings and supervision types, and positive robustness results. We report the new experiments once in the labeled meta-response sections **M1–M4** and answer your questions directly below.\n\n### 1. Were baselines given comparable orientation treatment?\n\nThe submission retained each reproduced baseline's native training pipeline, whereas EAMS used the bounded Fast-TGCN-style rotations in Appendix C. The augmentation policy was therefore not standardized or documented clearly enough.\n\nWe have now retrained every reported non-equivariant baseline with the same rotations, splits, and model-selection protocol as EAMS (**M1**). Matched augmentation improves several baseline results, but the central comparison remains: at 40°, the strongest augmented baselines remain substantially below EAMS on IntrA, 3D-IOSSeg, and both liver targets. Thus the reported stability is not explained by unequal rotation augmentation. We report only the primary overlap metric in M1 to save space; all other metrics have been computed and will be included in the revised manuscript.\n\n### 2. How stable are the PCA-derived frames?\n\nWe clarify the PCA equivariance claims at the start of **M4** before proceeding with a sensitivity analysis.\n\nThe liver frame is stable across the tested transformations: median and 90th-percentile label-flip rates are both zero, with probability drift $<10^{-3}$. The dental frame is stable in the median case, while its upper-tail variation is traced to one specific unresolved $(X,Z)\\mapsto(-X,-Z)$ sign choice. We will state this ambiguity and the conditions on the PCA claim explicitly in revisions.\n\n### 3. When is orientation nuisance variation versus useful anatomy?\n\nThe raw-coordinate diagnostic in **M2** makes EMNN orientation-sensitive. It improves liver ridge Dice by 5.49 and 3D-IOSSeg IoU by 4.79, but reduces IntrA aneurysm Dice by 5.40. This matches the dataset conventions: liver and dental meshes are consistently aligned, allowing location priors to be exploited; IntrA orientation is arbitrary, making the same dependence harmful. \n\nWe will therefore distinguish arbitrary coordinate pose from consistent dataset alignment. The result also motivates hybrid pose-aware/equivariant models, but implementing and evaluating such a model properly is beyond the scope of this submission.\n\n### 4. Can the gains be isolated more clearly?\n\nYes. Submitted Table 4 isolates HKS and dihedral features; **M3** isolates SRA/VN using a common task-specific base and a parameter-matched wider EMNN. For IntrA, this base includes the global node; for 3D-IOSSeg, it includes the global node and PCA features.\n\nThe wider 160-dim control does not reproduce the gains. Full VN improves the base from 92.36 to 94.51 IntrA Dice and from 76.76 to 81.74 3D-IOSSeg IoU. SRA likewise improves both tasks, but the effect of its auxiliary loss is task-dependent. The results show that the VN gains are not explained by parameter count and clarify the distinct empirical behavior of the two global-context mechanisms.\n\n### 5. Novelty and significance\n\nThe contribution is indeed not a new group-equivariant model or primitive. It centers on the study of structured multi-token global context beyond EMNN's shared global node, together with a controlled study of how intrinsic geometry, anatomical features, and pose priors interact across four benchmarks of vertex-, face-, and edge-level supervision. The orientation-matched experiments strengthen the central practical conclusion: equivariance is especially valuable when orientation is uncontrolled, while consistent alignment (teeth and liver) can supply useful pose information.\n\n### 6. Robustness scope and reproducibility\n\nThe additional random-axis evaluation in **M1** broadens the tested transformations beyond fixed z-rotations. We will more explicitly describe these synthetic transformations as coordinate-frame stress tests, without overclaiming closeness to acquisition-domain shifts.\n\nDue to concurrent extensions in development, the codebase is currently not in a state fit for release. With the camera-ready paper, we will release training code on GitHub, which includes mesh preprocessing and label conversion; HKS-cache generation; PCA-frame construction. We also include split definitions and example configurations in the repo. \n\n**Summary.** The matched-baseline evaluation directly resolves the principal fairness concern, while **M2–M4** answer the requested questions about pose, component isolation, and PCA stability. **In light of these clarifications, would you consider increasing your score for our paper? If any concrete concern still prevents an increased score, please identify it so that we may address it during the remaining discussion period.**"+ },+ "createdAt": "2026-07-31T10:45:45.475Z",+ "modifiedAt": "2026-11-19T17:05:45.721Z",+ "url": "https://openreview.net/forum?id=NHNCBuH2mF¬eId=8WkmJ5R436",+ "license": "CC-BY-4.0"+}
reviews/openreview/nhncbuh2mf/notes/azhdtnnuob.json added
+++ b/reviews/openreview/nhncbuh2mf/notes/azhdtnnuob.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "AzHDTNnUOB",+ "replyTo": "30Vedj724A",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer TBA9",+ "comment": "Thank you for your review! We also appreciate your recognition of the problem motivation, exposition, parameter efficiency, and evaluation across anatomical settings and supervision types. We report new experiments once in the labeled meta-response sections **M1–M4** and answer your questions directly below.\n\n### 1. Novelty and contribution\n\nThe contribution is not a new group-equivariant architecture or primitive. EAMS develops and evaluates a lightweight design for anatomical mesh segmentation: it augments EMNN's shared global node with two multi-token global-context mechanisms, integrates intrinsic and anatomy-aware features while preserving the relevant group action, and tests these choices across four benchmarks with vertex-, face-, and edge-level supervision.\n\nThe study also exposes a central tension: arbitrary coordinate pose should be removed, yet consistent dataset alignment can encode useful anatomical cues. **M2** shows that pose-sensitive coordinates help aligned liver and dental data but harm arbitrarily oriented IntrA.\n\n### 2. Rationale and gains of SRA/VN\n\nBoth modules address the limitation of EMNN's few-hop receptive field without substantially deepening the network, but impose different inductive biases:\n\n- **SRA** assigns vertices to soft regions, pools and mixes regional summaries, then scatters them back. It is a structured compression bottleneck; diversity discourages redundant assignments and equipartition discourages mass collapse.\n- **VN** uses coordinate-featured global tokens that exchange equivariant messages with all vertices. It makes no regional-partition assumption and is more flexible, but more sensitive to token count (Table 4). Repulsion discourages collapse; attraction keeps the tokens coupled to the mesh.\n\nThe common-base and parameter-matched ablation in **M3** clarifies the gains and selection rule. Without auxiliary regularization, both modules improve the task-specific base on IntrA and IOSSeg; the width-160 parameter-matched EMNN does not, ruling out added capacity as the explanation. VN performs best overall and is our evidence-backed default; SRA is a competitive structured alternative when regional compression is preferred. Full VN improves every reported metric over unregularized VN, whereas SRA regularization is task-dependent, although both SRA variants exceed the base on both tasks. We will narrow the claim accordingly: VN regularization is consistently helpful here, while SRA regularization should be selected by validation.\n\n### 3. Rotation-augmented baselines and fairness\n\nThe submission retained each reproduced baseline's native training pipeline, while EAMS used the bounded Fast-TGCN-style rotations in Appendix C; this orientation treatment was not standardized or documented clearly enough.\n\nWe have now retrained every reported non-equivariant baseline with the same rotations, splits, preprocessing, and model-selection protocol as EAMS (**M1**). Augmentation improves several baseline results, but does not explain the robustness gap: at 40°, the strongest augmented baseline remains substantially below EAMS on IntrA, 3D-IOSSeg, and both liver targets. We report only the primary overlap metric in M1 to conserve characters; all secondary metrics have been computed and will be included in the revision.\n\n### 4. Clinical significance\n\nThe synthetic transformations are controlled coordinate-frame stress tests, not estimates of how often a specific perturbation occurs clinically. Their purpose is to test dependence on an arbitrary representation choice under identical anatomy. **M1** broadens the original fixed-axis tests with random axes and larger angles, showing that matched augmentation does not close the gap. Meanwhile, **M2** shows why canonical-pose performance may also be useful. We will highlight this scope explicitly and frame the result as robustness to coordinate-pose variation.\n\n### 5. Reproducibility\n\nThe main text presents the design and principal protocol; the appendices provide the full algorithms, preprocessing, feature construction, loss weights, and some model configurations, **as necessitated by the page limit.** Anyways, with the camera-ready paper, we will release the training code and configurations, including mesh preprocessing and label conversion, HKS-cache generation, PCA-frame construction, and split definitions.\n\n**Summary.** **M1** resolves the fairness question with orientation-matched baselines; **M2** clarifies when pose is nuisance variation or useful context; and **M3** isolates the global-context modules from parameter count and auxiliary regularization. **In light of these clarifications, would you consider increasing your score for our paper? If any concrete concern still prevents an increased score, please identify it so that we may address it during the remaining discussion period.**"+ },+ "createdAt": "2026-07-31T11:01:54.016Z",+ "modifiedAt": "2026-11-19T17:05:45.553Z",+ "url": "https://openreview.net/forum?id=NHNCBuH2mF¬eId=AzHDTNnUOB",+ "license": "CC-BY-4.0"+}
reviews/openreview/nhncbuh2mf/notes/nrjzxzidnb.json added
+++ b/reviews/openreview/nhncbuh2mf/notes/nrjzxzidnb.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "NRjzXzidnb",+ "replyTo": "oiWoSg1Tx2",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer vTFs (Part 2)",+ "comment": "### 4. Why is EAMS stronger under rotation?\n\nFor exact EMNN features, a rigid transformation rotates vector channels while leaving scalar channels unchanged; equivariant message passing preserves these transformation types, and the scalar segmentation logits are therefore invariant. SRA preserves this property through invariant assignments and scalar region mixing, while VN exchanges equivariant messages with coordinate-bearing global tokens. Consequently, rotating the same anatomy does not require the model to relearn every pose from data.\n\nNon-equivariant baselines can approximate this behavior through augmentation, but have no architectural guarantee outside the sampled training transformations. **M1** tests this explanation under matched training: augmentation improves several baselines, yet they remain substantially less stable at 40° and under random-axis perturbations. For dental and liver EAMS, this argument additionally depends on the PCA-derived canonical features; their conditions and measured stability are reported in **M4**.\n\n### 5. Contribution-type clarification\n\nThe reviewer selected **Use-inspired**, whereas we selected **General**. This is not a disagreement about the substance of the work, but we chose General deliberately: the paper develops and evaluates an ML method using curated research datasets and does not clinical workflow validation or domain-expert co-design. We therefore preferred not to overstate its present application readiness. \n\n**Summary.** The new failure analysis identifies highly curved ligament geometry as the clearest remaining challenge; **M1** establishes the rotation advantage under matched augmentation; **M2** explains when canonical pose helps existing methods; and **M4** separates architectural invariance from data-dependent canonicalization. **We therefore ask that you maintain your accept score. If any concrete concern remains, please identify it so that we can address it during the remaining discussion period.**"+ },+ "createdAt": "2026-07-31T10:59:00.925Z",+ "modifiedAt": "2026-11-19T17:05:45.600Z",+ "url": "https://openreview.net/forum?id=NHNCBuH2mF¬eId=NRjzXzidnb",+ "license": "CC-BY-4.0"+}
reviews/openreview/nhncbuh2mf/notes/oiwosg1tx2.json added
+++ b/reviews/openreview/nhncbuh2mf/notes/oiwosg1tx2.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "oiWoSg1Tx2",+ "replyTo": "Mnv8DNxJoi",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer vTFs (Part 1)",+ "comment": "Thank you for your review! We also appreciate your recognition of the problem motivation, broader applicability, and evaluation breadth across anatomical settings and supervision types. We report new experiments once in the labeled meta-response sections **M1–M4** and answer your questions directly below.\n\n### 1. Where does the method fail?\n\nWe analyzed held-out liver meshes, where the submission shows the clearest room for improvement, using the base EAMS and the strongest VN+EAMS variant. Across each fold, we computed Spearman correlations between per-mesh Dice and descriptors of target geometry, global shape, PCA-frame conditioning, and mesh discretization. Below we report descriptors whose association had the same sign in all folds; values are median correlations across folds. We will also add images of representative lowest-scoring cases in the revision.\n\n#### EAMS — ligament Dice\n\n| Descriptor | Median $\\rho$ |\n|---|---:|\n| Ligament curvature, mean | −0.556 |\n| PCA eigengap 1–2 | −0.457 |\n| Background curvature w/o ligament, mean | −0.393 |\n| Background curvature w/o ridge, mean | −0.393 |\n| Ridge curvature, mean | −0.355 |\n\n#### EAMS — ridge Dice\n\n| Descriptor | Median $\\rho$ |\n|---|---:|\n| Normalized edge length, mean | −0.332 |\n\n#### VN+EAMS — ligament Dice\n\n| Descriptor | Median $\\rho$ |\n|---|---:|\n| Ligament curvature, mean | −0.559 |\n| Ridge curvature, mean | −0.430 |\n| Background curvature w/o ligament, mean | −0.427 |\n| Background curvature w/o ridge, mean | −0.427 |\n| PCA eigengap 1–2 | −0.400 |\n| PCA eigengap 2–3 | 0.347 |\n| Ridge curvature contrast | −0.313 |\n\n#### VN+EAMS — ridge Dice\n\n| Descriptor | Median $\\rho$ |\n|---|---:|\n| PCA sign margin, axis 1 | −0.412 |\n| PCA eigengap 2–3 | 0.365 |\n| PCA sign margin, axis 2 | −0.358 |\n| PCA eigengap 1–2 | −0.343 |\n| Normalized edge length, mean | −0.301 |\n\nThe clearest shared pattern is ligament geometry: higher mean ligament curvature is associated with lower Dice for both EAMS ($\\rho=-0.556$) and VN+EAMS ($\\rho=-0.559$). Several surrounding-curvature descriptors show the same direction, indicating that thin, highly curved ligament regions remain the principal challenge even after adding global context. By contrast, base EAMS ridge Dice has only one consistently associated descriptor; most measured descriptors have correlations near zero or signs that vary across folds. VN+EAMS ridge performance has moderate associations with global-shape and frame descriptors, but the opposite signs of the two eigengap associations do not indicate one general eigengap failure. The direct sensitivity analysis in **M4** separately shows stable liver frames and predictions under the tested transformations.\n\n### 2. Statistical comparisons\n\nThe paper reports mean ± SD over five held-out folds. Although formal uncertainty analysis (e.g. p-values) can complement these summaries, for the primary robustness comparisons, the differences are quite large relative to the reported fold variation. For example, under matched augmentation at 40°, the strongest IntrA baseline obtains 81.75 aneurysm Dice versus 93.59–95.81 for EAMS variants; the strongest IOSSeg baseline obtains 52.33 IoU versus 80.09 for VN+EAMS (**M1**). Thus the central conclusion does not depend on a marginal difference between means. If the reviewer feels this is needed for establishing specific claims, please mention it and we will prioritize it during discussion.\n\n### 3. Why are existing baselines stronger in some cases?\n\nThe main case is canonical liver ligament segmentation, where MeshGraphCNN retains a substantial advantage. **M2** tests the explanation directly by appending centred raw coordinates to EMNN. Making the model pose-sensitive improves liver ligament/ridge Dice by 1.96/5.49 and IOSSeg IoU by 4.79, but reduces IntrA aneurysm Dice by 5.40. Consistently aligned liver and dental datasets therefore permit models to exploit dataset-level location and orientation cues; removing those cues creates the reported canonical-accuracy/rotation-robustness trade-off. IntrA meshes have arbitrary orientation, so the same pose dependence is harmful."+ },+ "createdAt": "2026-07-31T10:56:46.746Z",+ "modifiedAt": "2026-11-19T17:05:45.602Z",+ "url": "https://openreview.net/forum?id=NHNCBuH2mF¬eId=oiWoSg1Tx2",+ "license": "CC-BY-4.0"+}
reviews/openreview/nhncbuh2mf/notes/teu5l84cz7.json added
+++ b/reviews/openreview/nhncbuh2mf/notes/teu5l84cz7.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "teU5L84cZ7",+ "replyTo": null,+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Discussion",+ "comment": "As we enter the final discussion period, would the reviewers please take a look at our responses and consider updating their scores if their feedback has been adequately addressed?\n\nThanks!"+ },+ "createdAt": "2026-08-03T18:40:48.260Z",+ "modifiedAt": "2026-11-19T17:05:45.524Z",+ "url": "https://openreview.net/forum?id=NHNCBuH2mF¬eId=teU5L84cZ7",+ "license": "CC-BY-4.0"+}
reviews/openreview/nhncbuh2mf/notes/wybx473mq6.json added
+++ b/reviews/openreview/nhncbuh2mf/notes/wybx473mq6.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "WybX473mq6",+ "replyTo": "zI8R18VmRw",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Meta-response (Part 2)",+ "comment": "### M3 — Global-context ablations\n\nWe compare SRA/VN variants against the same task-specific EAMS base and a width-160, parameter-matched EMNN. For IntrA, the base adds the global node; for 3D-IOSSeg, it adds the global node and PCA features. Submitted Table 4 separately ablates HKS and dihedral features.\n\n| Variant | IntrA Dice | IntrA IoU | 3D-IOSSeg IoU |\n|---|---:|---:|---:|\n| EMNN, no boundary loss | 91.03 | 85.22 | 29.97 |\n| + boundary-aware loss | 91.56 | 85.81 | 32.50 |\n| Task-specific EAMS base | 92.36 | 86.92 | 71.64 |\n| Base + SRA, no SRA regularization | 93.79 | 89.33 | 74.49 |\n| Base + full SRA | 92.97 | 88.19 | 75.61 |\n| Base + VN, no VN regularization | 93.39 | 90.16 | 80.65 |\n| Base + full VN | **94.51** | **91.28** | **81.74** |\n| Parameter-matched width-160 EMNN | 90.40 | 84.31 | 72.22 |\n\nThe capacity control does not reproduce the gains. VN improves both task-specific bases, including without its auxiliary loss, and the full VN loss improves further. SRA likewise improves both tasks, but the effect of its auxiliary loss is task-dependent. These targeted ablations were conducted on *one* fold.\n\n### M4 — PCA-frame stability and wording\n\n**Clarifying the \"approximate\" invariance.** For centred coordinates with covariance C, a rotation R gives $C(RX)=RCR^\\top$. With distinct eigenvalues and fixed ordering, PCA eigenvectors transform as $RF$, up to independent signs; repeated or near-repeated eigenvalues also permit rotations within an eigenspace. Thus, we emphasize that PCA supplies an **E(3)-equivariant set** of candidate frames, while a unique invariant coordinate system additionally requires **consistent sign selection**; this latter requirement is the source of the \"approximation\". We will further highlight these conditions in Appendix B.\n\nWe tested 16 random-axis rotations per held-out mesh, recomputed each frame, and measured maximum absolute input-feature drift, predicted-label flip fraction, and maximum class-probability drift. Values are median / 90th percentile across mesh–rotation trials:\n\n| Dataset | Feature drift | Prediction flips | Probability drift |\n|---|---:|---:|---:|\n| Liver | 1.33e−6 / 7.70e−6 | 0 / 0 | 2.35e−6 / 2.47e−4 |\n| 3D-IOSSeg | 3.05e−5 / 54.3 | 0 / 0.133 | 3.60e−5 / 0.998 |\n\nThe liver construction resolves two axis signs using weighted asymmetry and deterministic fallbacks, then derives the third by a cross product, producing stable results on the evaluated data. The dental construction resolves the anterior–posterior axis (in our case, the $Y$-axis) from dental arch concavity and enforces right-handedness, but, as we found out performing this analysis, does not distinguish the simultaneous $(X,Z)\\mapsto(-X,-Z)$ choice. This explains the observed upper-tail variation; the median feature and prediction behavior remains stable. We will state the remaining sign ambiguity explicitly and provide this explanation in the revisions.\n\nTogether, **M1–M4 directly address the fairness, isolation, and invariance questions raised in the reviews while preserving the main empirical conclusion: under matched training treatment, EAMS remains substantially more stable to orientation changes.**"+ },+ "createdAt": "2026-07-31T10:35:26.041Z",+ "modifiedAt": "2026-11-19T17:05:45.726Z",+ "url": "https://openreview.net/forum?id=NHNCBuH2mF¬eId=WybX473mq6",+ "license": "CC-BY-4.0"+}
reviews/openreview/nhncbuh2mf/notes/zi8r18vmrw.json added
+++ b/reviews/openreview/nhncbuh2mf/notes/zi8r18vmrw.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "zI8R18VmRw",+ "replyTo": null,+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Meta-response (Part 1)",+ "comment": "The meta-review identifies orientation-matched baseline evaluation as the principal issue. We therefore report that evaluation first, followed by targeted analyses requested across the reviews. Reviewer responses refer to the labels **M1–M4** below to avoid repeating results.\n\n### M1 — Orientation-matched baselines\n\n**Clarification.** In the submission, each reproduced baseline retained its native training pipeline, whereas EAMS used the bounded Fast-TGCN-style rotations in Appendix C. All methods used identical splits and compatible mesh preprocessing, but orientation augmentation was not standardized or documented clearly enough.\n\nWe retrained every reported non-equivariant baseline with the same stochastic rotations as EAMS: angles sampled uniformly from $[-0.15\\pi,0.15\\pi]$, using the same splits and model-selection protocol. Translation augmentation is unnecessary because every mesh is centered deterministically. \n\nWe additionally include a random axis-angle test which samples an axis uniformly on the sphere and an angle uniformly from $[-90^\\circ,90^\\circ]$. This represents a broadening of the bounded stress test, not necessarily an estimate of a clinical distribution. Reflections are used only as a coordinate-handedness test for IntrA.\n\nFor concision, we report the primary overlap metric here: Dice for liver/IntrA and the manuscript's average IoU for IOSSeg. The other reported metrics *have been computed* and will be included in the revised manuscript.Results are mean ± SD across five folds.\n\n#### Liver: Dice (%)\n\n| Model | Target | Canonical | Z-15° | Z-40° | Random axis |\n|---|---|---:|---:|---:|---:|\n| PointNet++ | Ligament | 36.18±2.54 | 25.60±3.90 | **11.79±2.21** | 20.36±2.45 |\n| | Ridge | 59.19±0.74 | **58.70±1.81** | **47.89±1.26** | **51.03±1.45** |\n| DGCNN | Ligament | 33.12±2.78 | 26.68±2.85 | 7.47±0.89 | 20.27±2.37 |\n| | Ridge | 58.20±2.60 | 57.79±1.80 | 42.42±0.59 | 46.80±3.74 |\n| MeshGraphCNN | Ligament | **44.13±0.94** | **29.50±0.62** | 6.21±0.44 | **21.94±0.71** |\n| | Ridge | **59.87±0.24** | 55.13±0.36 | 40.08±0.16 | 41.89±0.17 |\n\nMatched augmentation improves several perturbed scores but does not close the robustness gap: at 40°, the strongest baselines obtain 11.79 ligament and 47.89 ridge Dice, versus 26.33 and 58.51 for the corresponding EAMS variants in submitted Table 3. MeshGraphCNN remains stronger on canonical ligament Dice (44.13 versus 26.33), confirming the reported accuracy–robustness trade-off.\n\n#### IntrA: Dice (%)\n\n| Model | Target | Canonical | Z-15° | Z-40° | Reflection | Random axis |\n|---|---|---:|---:|---:|---:|---:|\n| DGCNN | Aneurysm | **88.17±1.69** | **87.45±1.71** | **81.75±0.40** | **81.28±2.76** | **79.62±1.30** |\n| | Parent | **97.16±0.59** | **96.91±0.64** | **95.65±0.19** | **95.85±0.34** | **95.21±0.19** |\n| PTv3 | Aneurysm | 81.29±5.28 | 80.36±4.96 | 77.24±4.26 | 74.70±4.44 | 76.93±4.80 |\n| | Parent | 95.28±1.38 | 95.11±1.25 | 94.31±1.05 | 93.67±0.87 | 94.03±1.04 |\n\nAugmented DGCNN improves over submitted Table 1, but its strongest 40° aneurysm result is 81.75 Dice, versus 93.59–95.81 for EAMS variants. The central IntrA result therefore holds under identical orientation augmentation.\n\n#### 3D-IOSSeg: average IoU (%)\n\n| Model | Canonical | Z-15° | Z-40° | Random axis |\n|---|---:|---:|---:|---:|\n| DGCNN | 65.92±0.92 | 58.08±0.72 | 37.92±0.49 | 28.18±0.33 |\n| PTv3 | 80.45±0.40 | **77.61±0.32** | 50.16±2.39 | 45.05±0.65 |\n| Fast-TGCN | **81.05±0.74** | 76.45±1.14 | **52.33±1.62** | **45.59±1.12** |\n\nPTv3 benefits substantially at 40°; Fast-TGCN is unchanged because this was already its native augmentation. The strongest baseline nevertheless falls from 81.05 canonical IoU to 52.33 at 40°, whereas VN+EAMS changes from 79.74 to 80.09 in submitted Table 2.\n\n\n### M2 — Pose information\n\nWe append centered raw $x,y,z$ coordinates to EMNN's scalar node features, deliberately making the predictor pose-sensitive:\n\n| Dataset / metric | Target | EMNN | + raw XYZ | Δ |\n|---|---|---:|---:|---:|\n| Liver Dice | Ligament | 19.33 | 21.29 | +1.96 |\n| | Ridge | 55.39 | 60.88 | +5.49 |\n| IntrA Dice | Parent | 96.43 | 94.57 | −1.86 |\n| | Aneurysm | 88.28 | 82.88 | −5.40 |\n| 3D-IOSSeg IoU | Average | 71.15 | 75.94 | +4.79 |\n\nThis diagnostic shows that pose-dependent coordinates can be exploited on canonically aligned liver and dental data, while the same dependence harms arbitrarily oriented IntrA. It supports the interpretation that the appropriate symmetry depends on the acquisition regime. We will distinguish arbitrary coordinate pose from consistent dataset alignment and discuss hybrid pose-aware/equivariant models as a natural extension. This targeted diagnostic was conducted on *one* fold."+ },+ "createdAt": "2026-07-31T10:33:11.404Z",+ "modifiedAt": "2026-11-19T17:05:45.745Z",+ "url": "https://openreview.net/forum?id=NHNCBuH2mF¬eId=zI8R18VmRw",+ "license": "CC-BY-4.0"+}
reviews/openreview/nhncbuh2mf/notes/zlfpnrxlpr.json modified
+++ b/reviews/openreview/nhncbuh2mf/notes/zlfpnrxlpr.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair 31RN","content": {- "metareview": "This paper studies whether one lightweight equivariant mesh network can deliver pose-robust anatomical segmentation across several anatomies and supervision types. It received one accept and two borderline accepts.\n\nI have read the authors' response, and it resolved the fairness question that drove my initial meta-review. The authors retrained every non-equivariant baseline with the same rotation augmentation, splits, and model selection as their own model. Matched augmentation improves the baselines, but it does not close the gap: at 40 degrees the strongest augmented baselines stay well below the equivariant model on the aneurysm, intraoral, and liver tasks. So the reported robustness is not an artifact of unequal augmentation. The authors also added a factorial ablation with a parameter-matched control that separates the module gains from added capacity, a pose diagnostic that explains the liver trade-off, and a stability analysis of the anatomy-aware frames. The borderline-reject reviewer raised the score and credited the matched-baseline result directly.\n\nI recommend acceptance. This is a useful and honest multi-anatomy robustness study with a compact model, and the central claim now rests on a fair comparison.\n\nThe authors should fold the matched-baseline results and the factorial ablation into the paper, separate the exact-invariance claim on the aneurysm task from the approximate-canonicalization results on the dental and liver tasks, and release the code and preprocessing as promised."+ "metareview": "This paper studies whether one lightweight equivariant mesh network can deliver pose-robust anatomical segmentation across several anatomies and supervision types. It received one accept and two borderline accepts.\n\nI have read the authors' response, and it resolved the fairness question that drove my initial meta-review. The authors retrained every non-equivariant baseline with the same rotation augmentation, splits, and model selection as their own model. Matched augmentation improves the baselines, but it does not close the gap: at 40 degrees the strongest augmented baselines stay well below the equivariant model on the aneurysm, intraoral, and liver tasks. So the reported robustness is not an artifact of unequal augmentation. The authors also added a factorial ablation with a parameter-matched control that separates the module gains from added capacity, a pose diagnostic that explains the liver trade-off, and a stability analysis of the anatomy-aware frames. The borderline-reject reviewer raised the score and credited the matched-baseline result directly.\n\nI recommend acceptance. This is a useful and honest multi-anatomy robustness study with a compact model, and the central claim now rests on a fair comparison.\n\nThe authors should fold the matched-baseline results and the factorial ablation into the paper, separate the exact-invariance claim on the aneurysm task from the approximate-canonicalization results on the dental and liver tasks, and release the code and preprocessing as promised.",+ "final_justification": "Accept. The rebuttal resolved the decisive baseline-fairness question: matched-augmentation baselines still fall well below EAMS at 40 degrees, and a parameter-matched factorial ablation isolates the module gains. One reviewer raised 3 to 4 on this basis; the other two are positive."},"createdAt": "2026-07-23T15:14:09.955Z",- "modifiedAt": "2026-11-18T15:20:50.267Z",+ "modifiedAt": "2026-11-19T05:00:32.175Z","url": "https://openreview.net/forum?id=NHNCBuH2mF¬eId=ZLFPNRXlpR","license": "CC-BY-4.0"}