Knowledge Transfer Scaling Laws for 3D Medical Imaging
Update NeurIPS 2026 submission mLgd1pC49X: 10 notes
@openreview[bot] · 2026-11-24 15:55 UTC · 35ab14a77356 ·
reviews/openreview/mlgd1pc49x/notes/5enryspso8.json added
+++ b/reviews/openreview/mlgd1pc49x/notes/5enryspso8.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "5EnRysPso8",+ "replyTo": "GiKNdbCcDG",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Rebuttal Block 3 for Reviewer R15S",+ "comment": "### W6. Why Transfer-Naïve underperforms Uniform and Data-Proportional\n\nWe agree that the poor Transfer-Naïve result required an explicit explanation. Transfer-Naïve uses the same fitted per-domain self-scaling parameters as Transfer-Aware, but deliberately removes all cross-domain transfer by setting $\\tau_{ij}=\\delta_{ij}$. Its surrogate therefore assumes that target domain $i$ benefits only from its directly allocated budget $h_iT$.\n\nThis is an intentionally misspecified ablation rather than an alternative practical mixture strategy. Once transfer is removed, the optimizer selects the mixture that is optimal under the false assumption that all domains are independent. It can therefore over-allocate to domains with favorable isolated scaling behavior while under-allocating to source domains whose data would benefit several targets simultaneously. Uniform and Data-Proportional are less\naggressive and can outperform this optimized but misspecified allocation. Such ablation should therefore be interpreted as testing whether per-domain scaling calibration alone is sufficient. Its failure shows that **optimizing separate scaling curves while ignoring cross-domain interactions can be harmful**. \n\nWe also agree that comparison with this ablation alone could exaggerate the apparent contribution of the transfer term. We therefore added RegMix and Data Mixing Laws as stronger practical baselines. At 100K, Transfer-Aware achieves 0.0264 MAE versus 0.0328 for RegMix and also outperforms RegMix on all six segmentation tasks. Thus, the empirical evidence for the method does not rely only on the large gap against the deliberately misspecified Transfer-Naïve ablation.\n\n### Q4. Stability across random seeds and model sizes\n\nFor seed stability, each $\\tau_{ij}$ is fitted jointly across three calibration budgets and 2--3 random seeds per budget, corresponding to 6--9 independent training runs per directed pair. We additionally performed 1,000 run-level bootstrap refits, jointly refitting the scaling laws, transfer matrix, and optimal mixture. The median cosine similarity to the reported allocation is 0.96. HN-PET remains above the allocation floor in 95.6% of refits and is the largest-weight domain in 82.5%; ABD-CT remains above the floor in 83.7%. Therefore, the qualitative hub-and-island structure is more stable than the exact numerical weights.\n\nFor model-size stability, the current evidence establishes transfer of the derived allocation, not invariance of every $\\tau_{ij}$. The allocation fitted using the small proxy improves the larger 121M encoder downstream, but we have not refitted the complete transfer matrix at multiple capacities. Since model size may change $E_i$, $\\beta_i$, and $\\tau_{ij}$, we now state direct cross-scale estimation and a joint $L(N,\\mathbf h,T)$ formulation as future work.\n\n### Q5. Practicality of $K^2$ estimation for 20--50 domains\n\nThe exhaustive procedure requires $K$ self-domain and $K(K-1)$ directed source - target configurations, or $K^2$ configurations in total: 36 for six domains, 400 for 20 domains, and 2,500 for 50 domains. Each configuration must also be evaluated over multiple budgets and seeds.\n\nThe proxy runs are small and parallelizable, so moderate expansion may remain feasible. However, we agree that exhaustive estimation for 50 domains would be expensive, and we do not claim that the current implementation scales unchanged to that setting.\n\nThe observed structured transfer matrix motivates sparse or low-rank estimation, hierarchical grouping by modality/anatomy, and uncertainty-guided selection of informative source--target pairs. These could substantially reduce the required experiments, but are not evaluated in the current work. We now identify the quadratic estimation cost explicitly as a limitation.\n\n### Q6. Clarification of the 12M and 121M parameter counts\n\nWe thank the reviewer for identifying an unclear architecture description. The two parameter counts correspond to different roles:\n\n- the **12M proxy model** is used for the self-domain and directed-transfer experiments required to estimate the mixture surrogate;\n- the **121M target encoder** is pretrained with the selected mixture and used for downstream classification and segmentation.\n\nThis proxy-to-target design is deliberate: running every domain pair, budget, and seed with the 121M model would remove much of the computational advantage of proxy-based mixture selection. However, the appendix did not separate the two configurations clearly enough. We will revise it to report their architectures, parameter counts, and experimental roles independently, and correct the compute discussion accordingly.\n\nThe downstream results support the specific claim that the proxy-derived allocation remains useful for the larger encoder. They do not prove that the fitted scaling and transfer parameters are invariant across model sizes, which\nwe will clarify as our future investigation."+ },+ "createdAt": "2026-07-28T17:14:44.570Z",+ "modifiedAt": "2026-11-19T16:49:53.995Z",+ "url": "https://openreview.net/forum?id=mLgd1pC49X¬eId=5EnRysPso8",+ "license": "CC-BY-4.0"+}
reviews/openreview/mlgd1pc49x/notes/b0bhk5zqoe.json added
+++ b/reviews/openreview/mlgd1pc49x/notes/b0bhk5zqoe.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "b0bhK5ZQOe",+ "replyTo": "d9M35EuZnc",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Follow-Up on the Rebuttal",+ "comment": "Thank you again for the encouraging assessment and constructive questions. We wanted to briefly follow up if the concerns and the corresponding questions have been well addressed or not.\n\nWe clarified that MAE reconstruction is a representation-learning proxy rather than a measure of anatomical fidelity, and that anatomical usefulness is evaluated through structure-aware organ and lesion segmentation. The Transfer-Aware mixture achieves the highest Dice on all six segmentation benchmarks, and we commit to adding qualitative CT/MRI/PET segmentation overlays in the revision. We also quantified the domains' modality, anatomy, resolution, and signal differences, providing better clarification by removing the unsupported “anatomical regularity” attribution, added an explicit comparison with Transfusion, and\nprovided the anonymized repository link here: https://anonymous.4open.science/r/transfer-aware-scaling-3d-med-4564.\n\nWe hope these changes fully address your three questions. Please let us know if any concern remains. If all the concerns are well addressed, we respectfully hope you will reconsider increasing the score."+ },+ "createdAt": "2026-08-01T19:08:31.582Z",+ "modifiedAt": "2026-11-19T16:49:53.843Z",+ "url": "https://openreview.net/forum?id=mLgd1pC49X¬eId=b0bhK5ZQOe",+ "license": "CC-BY-4.0"+}
reviews/openreview/mlgd1pc49x/notes/gikndbccdg.json added
+++ b/reviews/openreview/mlgd1pc49x/notes/gikndbccdg.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "GiKNdbCcDG",+ "replyTo": "Z1iCnWQnie",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Rebuttal Block 2 for Reviewer R15S",+ "comment": "### W3 / Q7. Comparison with learned and adaptive mixture methods\nWe agree that the original heuristic baselines were insufficient. We therefore added **RegMix** and **Data Mixing Laws** as stronger learned/scaling-law-based comparisons.\n\nFor RegMix, we sample anchored and Dirichlet mixtures under the same $5\\%$ allocation floor, train each with the same 3D MAE proxy, evaluate all six target domains, fit one LightGBM regressor per target, and optimize the mean predicted loss.\n\n| Mixture | 10K | 50K | 100K | 200K |\n|---|---:|---:|---:|---:|\n| Data Mixing Laws | 0.0855 | 0.0739 | 0.0395 | 0.0269 |\n| RegMix | 0.09346 | **0.04367** | 0.03278 | 0.0224 |\n| **Transfer-Aware** | **0.08010** | 0.04510 | **0.02640** | **0.02240** |\n\nTransfer-Aware is 14.3% lower than RegMix at 10K and 19.5% lower at 100K; RegMix is 3.3% lower at 50K, and the methods are effectively tied at 200K. We therefore do not claim uniform dominance.\n\nWe also add Data Mixing Laws to the downstream comparison. RegMix learns a flexible mixture-to-loss regression, while Data Mixing Laws models the joint effect of mixture proportions and data scale. Our method instead explicitly separates domain scaling and directed source-to-target transfer through $\\beta_i$ and $\\tau_{ij}$, yielding budget-dependent and interpretable hub-and-island allocations. We view these methods as complementary.\n\n### W4 / Q1 / Q3. Downstream results for all mixture strategies\n\nWe agree that we should report both the Transfer-Naive and uniform mixture for the downstream performances. We now include Uniform, Transfer-Naïve, Data Mixing Laws, and RegMix.\n\n**Classification: Accuracy (AUC), %.**\n\n| Mixture | OASIS-1 | SynBrain-PET | OrganMNIST3D |\n|---|---:|---:|---:|\n| Uniform | 66.9 (73.6) | 69.7 (94.5) | 88.9 (99.4) |\n| Data-Proportional | 67.5 (76.0) | 71.9 (93.9) | 89.7 (99.4) |\n| Transfer-Naïve | 66.3 (76.3) | 73.6 (95.3) | 90.1 (99.5) |\n| Data Mixing Laws | 67.5 (79.3) | 73.2 (94.2) | 89.8 (99.4) |\n| RegMix | 68.8 (79.7) | 74.6 (95.3) | **91.5 (99.5)** |\n| **Transfer-Aware** | **69.7** (78.4) | **78.1 (95.9)** | 90.3 (99.4) |\n\n| Mixture | AMOS-CT | AMOS-MRI | BraTS-T1 | BraTS-T2 | HECKTOR | BHSD |\n|---|---:|---:|---:|---:|---:|---:|\n| Uniform | 81.6 | 68.8 | 50.4 | 61.4 | 67.8 | 57.2 |\n| Data-Proportional | 82.0 | 68.8 | 52.7 | 63.0 | 68.7 | 59.0 |\n| Transfer-Naïve | 81.3 | 66.9 | 50.5 | 61.1 | 68.0 | 57.5 |\n| Data Mixing Laws | 80.9 | 67.9 | 50.1 | 61.0 | 68.5 | 58.5 |\n| RegMix | 82.3 | 68.9 | 53.0 | 63.1 | 69.3 | 59.3 |\n| **Transfer-Aware** | **83.1** | **69.4** | **55.1** | **65.4** | **71.1** | **61.2** |\n\nTransfer-Aware achieves the highest Dice on all six segmentation tasks with the lowest MAE reconstruction loss, improving over RegMix by 0.5 - 2.3 points, with an average gain of 1.57 Dice. It also obtains the highest mean classification accuracy (79.4% versus 78.3% for RegMix), although RegMix performs best on OrganMNIST3D and slightly better on mean AUC.\n\nAcross the five strategies with corresponding 100K reconstruction MAE, the Spearman correlation is $\\rho=-0.82$ with mean Dice and $\\rho=-0.60$ with mean classification accuracy. Thus, lower MAE is strongly associated with dense prediction performance, but is not perfectly predictive of every classification metric. We therefore treat MAE as a mixture-selection proxy, not as a universal clinical representation metric.\n\n### W5. Budget dependence of the “up to 58%” result\n\nWe agree that emphasizing only the maximum improvement at 50K overstated the consistency of the gain across budgets. Using the paper’s relative-gap definition,\n\n$\\frac{L_{\\mathrm{baseline}}-L_{\\mathrm{TA}}}{L_{\\mathrm{TA}}}$,\n\nSo the complete results are:\n\n| Baseline | 10K | 50K | 100K | 200K | Mean |\n|---|---:|---:|---:|---:|---:|\n| Data-Proportional | 5% | 58% | 38% | 4% | 26% |\n| Uniform | 6% | 49% | 31% | 2% | 22% |\n| Transfer-Naïve | 4% | 77% | 51% | 26% | 40% |\n\nWe will therefore revise the abstract and main text to report the complete budget-dependent trend rather than anchoring the claim on “up to 58%.” A more precise statement is:\n\n> Transfer-Aware reduces reconstruction error most strongly in the intermediate\n> data regime; Data-Proportional incurs approximately 26% higher MAE on average\n> across budgets, with gaps ranging from 4% to 58%.\n\nThe budget dependence is itself informative. At 10K, all methods operate in a strongly data-limited regime and remain relatively close. At 100K, the largest calibration budget before the held-out 200K evaluation and the budget used for\ndownstream experiments -> the gap remains substantial at 38%. At 200K, the strongest methods converge as the fixed-capacity proxy approaches a loss-floor or capacity-limited regime. We therefore do not claim that the relative advantage is constant with scale, and we now explicitly distinguish the strongest intermediate-budget result from the smaller gains observed at the lowest and highest evaluated budgets."+ },+ "createdAt": "2026-07-28T17:00:35.201Z",+ "modifiedAt": "2026-11-19T16:49:54.048Z",+ "url": "https://openreview.net/forum?id=mLgd1pC49X¬eId=GiKNdbCcDG",+ "license": "CC-BY-4.0"+}
reviews/openreview/mlgd1pc49x/notes/gyhbdwjtzc.json added
+++ b/reviews/openreview/mlgd1pc49x/notes/gyhbdwjtzc.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "gYHBdWjtZc",+ "replyTo": "nd6FNk7hhh",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Summary of What We have Addressed",+ "comment": "We thank the meta-reviewer and all reviewers for their careful and constructive assessment. Across the reviews, the paper was recognized as addressing an important and timely problem in heterogeneous medical-image pretraining. Reviewers highlighted the simplicity and interpretability of the formulation, the directional transfer matrix and intuitive hub-and-island structure, the clear presentation, and the promising gains across budgets and downstream tasks. We also appreciate that the initial assessments identified important limitations requiring stronger evidence. We address the two recurring concerns below and summarize the new experiments.\n\n### 1. Robustness of the MAE objective and downstream effectiveness\n\nThis concern is addressed in **R2-W2/Q2**, **R2-W4/Q1/Q3**, and **R4-W1**.\n\nFor cross-modality robustness, CT, MRI, and PET inputs are modality-specifically preprocessed and normalized to $[-1,1]$ before MAE is computed. We further re-optimized the 100K mixture using dimensionless target-wise losses normalized by either each target's best single-domain reference or its Uniform-mixture loss. The resulting allocations remain close to the original solution (cosine similarity $0.93$--$0.97$) and preserve the same hub-and-island structure. Thus, the allocation is not driven by one modality having a larger absolute MAE scale.\n\nFor downstream effectiveness, we expanded the comparison to Uniform, Data-Proportional, Transfer-Naïve, Data Mixing Laws, RegMix, and Transfer-Aware. Transfer-Aware achieves the highest Dice on all six segmentation tasks, averaging $+1.57$ Dice over RegMix, and the highest mean classification accuracy ($79.4\\%$ vs. $78.3\\%$). Across strategies with matched 100K reconstruction losses, MAE correlates with mean Dice at $\\rho=-0.82$ and mean classification accuracy at $\\rho=-0.60$. These results support MAE as a useful mixture-selection proxy, particularly for dense prediction, while showing that it does not perfectly predict every downstream metric.\n\nThe framework is not mathematically restricted to MAE: another scalar per-domain validation objective (i.e. contrastive loss, Dino loss) can replace $L_i$ after refitting the corresponding scaling and transfer parameters. However, the parameters and optimal mixture are objective-specific. We therefore now describe MAE as a validated proxy in the evaluated setting, not as a universal measure of medical representation quality, and explicitly list robustness across alternative self-supervised objectives as future work.\n\n### 2. Differentiation from alternative mixture-optimization methods\n\nThis concern is addressed in **R2-W3/Q7** and **R4-W2**. We expanded both the related-work discussion and empirical evaluation beyond heuristic mixtures by adding **RegMix** and **Data Mixing Laws**.\n\nRegMix learns a flexible black-box mapping from mixture weights to validation loss, while Data Mixing Laws models mixture and data-scale effects. Our method instead separates target-specific scaling, $\\beta_i$, from directed source-to-target transfer, $\\tau_{ij}$. This yields budget-dependent allocations and an interpretable transfer matrix that identifies transferable hubs and domains requiring direct investment.\n\nEmpirically, Transfer-Aware is 14.3% lower than RegMix at 10K and 19.5% lower at 100K; RegMix is 3.3% lower at 50K, and the methods are effectively tied at 200K. Transfer-Aware also outperforms RegMix and Data Mixing Laws on all six segmentation tasks, while RegMix remains competitive on classification. We therefore do not claim uniform dominance.\n\nWe also clarify the distinction from temperature sampling and DoReMi. DoReMi performs online group-robust reweighting and changes the training objective, whereas the evaluated baselines select fixed mixtures under the same pretraining objective and budget. We therefore view DoReMi-style adaptive training as complementary and explicitly acknowledge that our experiments do not exhaust the rapidly growing mixture-optimization literature.\n\n### Overall Summary\nOverall, the rebuttal strengthens the paper along both dimensions emphasized by the meta-reviewer. It shows that the allocation structure is robust to cross-modality loss normalization and that the selected mixture transfers consistently to supervised medical tasks. It also adds stronger learned and scaling-law baselines while clarifying the method's distinct contribution: an interpretable, directional transfer model for budget-dependent mixture design. We have narrowed the claims accordingly: the contribution is a transfer-aware mixture-optimization framework validated in a controlled six-domain 3D setting, rather than a universal objective or exhaustive solution to medical-data mixture optimization."+ },+ "createdAt": "2026-08-01T18:41:04.465Z",+ "modifiedAt": "2026-11-19T16:49:53.943Z",+ "url": "https://openreview.net/forum?id=mLgd1pC49X¬eId=gYHBdWjtZc",+ "license": "CC-BY-4.0"+}
reviews/openreview/mlgd1pc49x/notes/hdeql9v6l0.json added
+++ b/reviews/openreview/mlgd1pc49x/notes/hdeql9v6l0.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "HdeQL9V6L0",+ "replyTo": "5EnRysPso8",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Rebuttal Block 4 for Reviewer R15S",+ "comment": "### Additional limitation: Is the 5% allocation floor arbitrary?\n\nThe floor was selected empirically rather than assumed without evaluation. Figure 5 in Appendix varies $\\epsilon$ from 2.5% to 12.5% and finds that mean MAE across the six targets is minimized at $\\epsilon$=5\\%. Lower floors over-concentrate the mixture on ABD-CT and HN-PET, whereas higher floors force budget toward domains already supported through incoming transfer.\n\nThe qualitative allocation remains stable across the evaluated range: ABD-CT and HN-PET remain the two domains above the floor. Thus, the hub-and-island result is not created by choosing exactly 5%. We nevertheless agree that the optimal regularization level may change for another domain set, and we now describe $\\epsilon$ as a tunable coverage constraint rather than a universal constant.\n\n### Additional limitation: Is validation of $\\tau$ circular?\n\nThe validation uses experimental configurations that are separate from those used to fit the relevant predictions. The transfer coefficients are estimated from pure-source-domain runs. They are then used to predict:\n\n1. held-out mixed-domain configurations, where predicted effective-budget changes correlate with observed loss improvements at $r=0.992$;\n2. the held-out 200K budget, where the predicted mean loss is 0.0227 versus 0.0224 observed, with per-domain $r=0.989$.\n\nThus, the same mixed configurations and held-out budget are not used both to fit and validate the prediction. We will clarify the fitting/evaluation split in the revised manuscript."+ },+ "createdAt": "2026-07-28T17:20:30.489Z",+ "modifiedAt": "2026-11-19T16:49:53.974Z",+ "url": "https://openreview.net/forum?id=mLgd1pC49X¬eId=HdeQL9V6L0",+ "license": "CC-BY-4.0"+}
reviews/openreview/mlgd1pc49x/notes/nd6fnk7hhh.json modified
+++ b/reviews/openreview/mlgd1pc49x/notes/nd6fnk7hhh.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair 7app","content": {- "metareview": "This paper studies the problem of data mixture optimization for medical imaging, where data is drawn from different medical image modalities (CT, MRI, and PET). The paper introduces a mixture-based scaling law and a corresponding optimization problem that minimizes MAE reconstruction error. \n\nInitial reviews of this paper are borderline. I recommend the authors to review and address all comments. I note two key comments observed by multiple reviewers below:\n- MAE as the loss to minimize may be limited both for downstream tasks dealing with medical imaging and with the diversity of modalities. How is the framework robust to alternative losses and are the current optimal data mixtures effective on downstream settings?\n- The paper includes some discussion in related literature corresponding to other mixture optimization algorithms. How does the method sufficiently differentiate itself or compare empirically against these alternatives? Here, I note that while RegMix is mentioned, it is one among a rapidly growing literature."+ "metareview": "This paper studies the problem of data mixture optimization for medical imaging, where data is drawn from different medical image modalities (CT, MRI, and PET). The paper introduces a mixture-based scaling law and a corresponding optimization problem that minimizes MAE reconstruction error. \n\nInitial reviews of this paper are borderline. I recommend the authors to review and address all comments. I note two key comments observed by multiple reviewers below:\n- MAE as the loss to minimize may be limited both for downstream tasks dealing with medical imaging and with the diversity of modalities. How is the framework robust to alternative losses and are the current optimal data mixtures effective on downstream settings?\n- The paper includes some discussion in related literature corresponding to other mixture optimization algorithms. How does the method sufficiently differentiate itself or compare empirically against these alternatives? Here, I note that while RegMix is mentioned, it is one among a rapidly growing literature.",+ "final_justification": "Thanks to the authors for a thorough rebuttal. All reviewers recommend acceptance noting that the rebuttal has addressed most of the initially raised concerns. I recommend the authors to incorporate the new analysis and discussions into the final version of the paper. Moreover, Reviewer foD1's initial review included a request for differentiation of hte work with Transfusion (Raghu et al). While the rebuttal includes some discussion, I strongly urge the authors to expand on this clarification further in their revision."},"createdAt": "2026-07-18T16:07:56.672Z",- "modifiedAt": "2026-11-18T15:20:53.152Z",+ "modifiedAt": "2026-11-19T05:00:33.206Z","url": "https://openreview.net/forum?id=mLgd1pC49X¬eId=nd6FNk7hhh","license": "CC-BY-4.0"}
reviews/openreview/mlgd1pc49x/notes/nyywpmd91b.json added
+++ b/reviews/openreview/mlgd1pc49x/notes/nyywpmd91b.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "NYYWPMd91B",+ "replyTo": "AfrNiyscpC",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Follow-Up on the Rebuttal",+ "comment": "Thank you again for the focused and constructive review. We wanted to follow up now that the additional experiments addressing your main concerns are complete and check if the concerns and the corresponding questions have been well addressed or not.\n\nFirst, we expanded downstream evaluation across Uniform, Data-Proportional, Transfer-Naïve, Data Mixing Laws, RegMix, and Transfer-Aware. Transfer-Aware achieves the highest Dice on all six segmentation tasks and the highest mean classification accuracy, supporting MAE as a useful mixture-selection proxy rather than merely a low-level reconstruction metric.\n\nSecond, we added direct comparisons with **RegMix** and **Data Mixing Laws**. Transfer-Aware is better than RegMix at 10K and 100K, RegMix is slightly better at 50K, and they are effectively tied at 200K; we therefore explicitly avoid a claim of uniform dominance. Finally, we now report the full budget-dependent trend and narrow our claim: the method is most useful in the data-limited regime common to heterogeneous medical pretraining, rather than being claimed to provide constant gains at every scale.\n\nWe hope these new results and the revised framing address your concerns. We would appreciate any remaining feedback and respectfully hope you might reconsider your assessment if the concerns have been resolved."+ },+ "createdAt": "2026-08-01T19:12:37.253Z",+ "modifiedAt": "2026-11-19T16:49:54.366Z",+ "url": "https://openreview.net/forum?id=mLgd1pC49X¬eId=NYYWPMd91B",+ "license": "CC-BY-4.0"+}
reviews/openreview/mlgd1pc49x/notes/ufpnv1xroh.json added
+++ b/reviews/openreview/mlgd1pc49x/notes/ufpnv1xroh.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "UfpNV1XroH",+ "replyTo": "UXviqdDDXi",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Follow-Up on the Rebuttal",+ "comment": "Thank you again for the detailed and technically engaged review. We wanted to follow up now that the additional experiments and analyses described in our responses are complete, and check if the concerns and the corresponding questions have been well addressed or not.\n\nIn particular, we have: (1) tested target-wise normalized objectives, which preserve the hub-and-island allocation structure with cosine similarity $0.93$-$0.97$; (2) expanded downstream evaluation to all mixture strategies; and (3) added RegMix and Data Mixing Laws as stronger learned/scaling-law baselines. Transfer-Aware achieves the highest Dice on all six segmentation tasks, averaging $+1.57$ Dice over RegMix, and the highest mean classification accuracy. We also clarified the budget-dependent gains, the role of the Transfer-Naïve ablation, seed stability, $K^2$ estimation cost, and the 12M-proxy-to-121M-target design.\n\nWe hope these additions address the central concerns in your review. We would be grateful to know whether any major concern remains. If the responses have resolved them, we respectfully hope you might reconsider your assessment."+ },+ "createdAt": "2026-08-01T19:03:26.466Z",+ "modifiedAt": "2026-11-19T16:49:53.867Z",+ "url": "https://openreview.net/forum?id=mLgd1pC49X¬eId=UfpNV1XroH",+ "license": "CC-BY-4.0"+}
reviews/openreview/mlgd1pc49x/notes/yullxhq8hu.json added
+++ b/reviews/openreview/mlgd1pc49x/notes/yullxhq8hu.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "YUlLxhq8HU",+ "replyTo": "fx19sKBbZw",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Updates on RegMix for Abdomen MRI Segmentation",+ "comment": "| Pretraining Mixture | AMOS-CT | AMOS-MRI | BraTS-T1 | BraTS-T2 | HECKTOR | BHSD |\n|---|---:|---:|---:|---:|---:|---:|\n| RegMix | 82.3 | 68.9 | 53.0 | 63.1 | 69.3 | 59.3 |\n| **Transfer-Aware** | **83.1** | **69.4** | **55.1** | **65.4** | **71.1** | **61.2** |"+ },+ "createdAt": "2026-07-29T04:41:54.667Z",+ "modifiedAt": "2026-11-19T16:49:53.945Z",+ "url": "https://openreview.net/forum?id=mLgd1pC49X¬eId=YUlLxhq8HU",+ "license": "CC-BY-4.0"+}
reviews/openreview/mlgd1pc49x/notes/z1icnwqnie.json added
+++ b/reviews/openreview/mlgd1pc49x/notes/z1icnwqnie.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "Z1iCnWQnie",+ "replyTo": "UXviqdDDXi",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Rebuttal Block 1 for Reviewer R15S",+ "comment": "We thank the reviewer for the detailed, constructive, and technically engaged assessment. The review identifies several important issues concerning experimental scale, cross-modality loss aggregation, learned-mixture baselines, downstream validation, and the interpretation of our ablations. These comments motivated new analyses and experiments. Because the concerns are technically\ndistinct, we address them in a sequence of comments following the reviewer’s original ordering.\n\n### W1. Experimental scale and relevance to clinical foundation-model pretraining\nWe agree that experiments on six domains with 150--500 selected volumes per domain are not sufficient to establish generalization to all clinical foundation-model pretraining settings. We will therefore revise the wording from broad “guidance for 3D medical foundation models” to a **transfer-aware mixture-optimization framework validated in a controlled, heterogeneous 3D medical setting**.\n\nThe current experiments are intended as a tractable proof of concept across CT, MRI, PET, multiple anatomies, and imbalanced domain sizes. Within this setting, the proxy-derived scaling law predicts the held-out 200K budget with 1.2% error and $r=0.989$ across domains, and the resulting mixture improves the larger 121M encoder on classification and all six segmentation tasks. These results support generalization beyond the fitted proxy configurations, but not to arbitrarily larger clinical datasets, domain collections, or model capacities. We will also explicitly state this limitation and identify validation on larger clinical data populations, more domains, and multiple model sizes as necessary future work.\n\n### W2 / Q2. Commensurability of the cross-modality MAE objective\n\nWe agree that directly averaging reconstruction losses computed on raw CT, MRI, and PET intensity scales would be inappropriate, because the modality with the largest numerical range could dominate the objective. However, the losses used in our optimization are **not computed on raw HU, MRI intensities, or PET SUVs**. Each domain first undergoes **modality-** and **anatomy-specific preprocessing** and is mapped to the common range $[-1,1]$ before MAE is measured. Therefore, the original intensity dynamic range cannot directly determine a domain’s contribution to the objective.\n\nWe nevertheless agree that placing all modalities on the same numerical range does not guarantee that one unit of MAE has identical semantic meaning across domains. We therefore conducted an additional sensitivity analysis using dimensionless, target-specific relative losses. For a candidate mixture $\\mathbf h$, let $L_i(\\mathbf h,T)$ denote its predicted MAE on target domain $i$ at budget $T$. We evaluate two alternative normalizations:\n\n1. **Relative MAE versus the single-domain reference.** For each target, we divide its predicted loss by the lowest target-domain loss obtained from the pure single-domain pretraining configurations at the same budget.\n\n2. **Relative MAE versus Uniform pretraining.** For each target, we divide its predicted loss by that target’s loss under the Uniform mixture at the same budget.\n\n| Objective at $T=100$K | ABD-CT | ABD-MRI | BRAIN-T1 | BRAIN-T2 | HN-CT | HN-PET | Cosine vs. original |\n|---|---:|---:|---:|---:|---:|---:|---:|\n| Unnormalized mean MAE | 26.7 | 5.0 | 5.0 | 5.0 | 5.0 | 53.3 | 1.000 |\n| Relative MAE vs. single-domain reference | 6.0 | 5.0 | 5.0 | 5.0 | 5.0 | 74.0 | 0.928 |\n| Relative MAE vs. Uniform reference | 14.2 | 5.0 | 5.0 | 5.0 | 5.0 | 65.8 | 0.969 |\n\nAlthough the exact allocation between ABD-CT and HN-PET changes, the main structure is preserved under both alternatives. The normalized solutions have cosine similarity $0.93$--$0.97$ to the original allocation. Thus, the hub-and-island conclusion is not caused by one modality having a larger absolute MAE scale.\n\nWe also clarify that this concern does not directly propagate to the downstream metrics, which are independently measured using supervised accuracy, AUC, and Dice. It could propagate indirectly if the MAE objective selected a poor pretraining mixture. We test this possibility through the expanded downstream comparison across all mixture strategies: the mixture selected by our objective\nachieves the highest Dice on all six segmentation tasks and the highest mean classification accuracy. We therefore treat MAE as a mixture-selection proxy whose validity must be established through downstream transfer, rather than as a direct clinical-quality metric.\n\nFinally, the unweighted mean represents an **equal-target default**, not a claim that all modalities have equal clinical importance. The framework directly supports an application-specific weighted objective, when particular modalities, anatomies, or clinical tasks should receive greater priority. We will clarify this assumption and add the normalization-sensitivity analysis to the revised manuscript."+ },+ "createdAt": "2026-07-28T16:54:58.020Z",+ "modifiedAt": "2026-11-19T16:49:54.048Z",+ "url": "https://openreview.net/forum?id=mLgd1pC49X¬eId=Z1iCnWQnie",+ "license": "CC-BY-4.0"+}