Update NeurIPS 2026 submission GmZxHeBKTq: 11 notes
@openreview[bot] · 2026-11-24 15:48 UTC · e7548358befd ·
reviews/openreview/gmzxhebktq/notes/2nowwv0yx9.json modified
+++ b/reviews/openreview/gmzxhebktq/notes/2nowwv0yx9.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair 6wqj","content": {- "metareview": "The paper proposes a three-stage radiology report generation framework. A self-evolving RadSkill repository is refined by a failure-driven loop; a teacher model uses the repository to generate clinical reasoning trajectories that a report generator internalizes through SFT so no explicit reasoning chain is needed at inference; and Psychometric Preference Optimization (PSY-PO) treats historical checkpoints as examinees under Item Response Theory to select clinically misleading hard negatives for preference training. Experiments on MIMIC-CXR and IU X-Ray report improvements over a report-only baseline and several prior RRG systems.\n\nThe concerns from reviewers are as follows:\n\n1) Hallucination evidence. A trustworthiness/hallucination-reduction paper needs human evaluation beyond NLG and CE metrics (Reviewer oecC); Reviewer jtfF sharpens this by asking for entity/relation, anatomy-location, or negation/uncertainty error analysis.\n\n2) Trajectory faithfulness. CheXbert/RadGraph signals appear both in method construction and evaluation, weakening independence, and the SECR trajectories need auditing on cases where the teacher adds, misses, or contradicts findings (Reviewer jtfF and Reviewer w3ai).\n\n3) Baseline comparability and uncertainty. It is unclear which Table 3 baselines were rerun under identical preprocessing versus cited (Reviewer jtfF); Reviewer oecC notes Tables 1-3 have no error bars, and Reviewer w3ai independently asks why Rep-SFT in Table 2 looks stronger than several SOTA methods in Table 3.\n\n4) Related-work coverage and reproducibility. Reasoning-focused RRG methods (RadAgents, CheXOne, ORGAN, CoMT) are missing (Reviewer oecC); Reviewer jtfF asks for PSY-PO construction details (candidate pool size, perturbation prompts, decoding, 3PL fitting) and flags a stray checklist template block."+ "metareview": "The paper proposes a three-stage radiology report generation framework. A self-evolving RadSkill repository is refined by a failure-driven loop; a teacher model uses the repository to generate clinical reasoning trajectories that a report generator internalizes through SFT so no explicit reasoning chain is needed at inference; and Psychometric Preference Optimization (PSY-PO) treats historical checkpoints as examinees under Item Response Theory to select clinically misleading hard negatives for preference training. Experiments on MIMIC-CXR and IU X-Ray report improvements over a report-only baseline and several prior RRG systems.\n\nThe concerns from reviewers are as follows:\n\n1) Hallucination evidence. A trustworthiness/hallucination-reduction paper needs human evaluation beyond NLG and CE metrics (Reviewer oecC); Reviewer jtfF sharpens this by asking for entity/relation, anatomy-location, or negation/uncertainty error analysis.\n\n2) Trajectory faithfulness. CheXbert/RadGraph signals appear both in method construction and evaluation, weakening independence, and the SECR trajectories need auditing on cases where the teacher adds, misses, or contradicts findings (Reviewer jtfF and Reviewer w3ai).\n\n3) Baseline comparability and uncertainty. It is unclear which Table 3 baselines were rerun under identical preprocessing versus cited (Reviewer jtfF); Reviewer oecC notes Tables 1-3 have no error bars, and Reviewer w3ai independently asks why Rep-SFT in Table 2 looks stronger than several SOTA methods in Table 3.\n\n4) Related-work coverage and reproducibility. Reasoning-focused RRG methods (RadAgents, CheXOne, ORGAN, CoMT) are missing (Reviewer oecC); Reviewer jtfF asks for PSY-PO construction details (candidate pool size, perturbation prompts, decoding, 3PL fitting) and flags a stray checklist template block.",+ "final_justification": "During the rebuttal phase, the reviewers acknowledged that their concerns had been adequately addressed and provided positive evaluations."},"createdAt": "2026-07-22T09:05:31.391Z",- "modifiedAt": "2026-11-18T15:21:02.226Z",+ "modifiedAt": "2026-11-19T05:00:38.269Z","url": "https://openreview.net/forum?id=GmZxHeBKTq¬eId=2nOwwv0yx9","license": "CC-BY-4.0"}
reviews/openreview/gmzxhebktq/notes/4ln76g9b6i.json added
+++ b/reviews/openreview/gmzxhebktq/notes/4ln76g9b6i.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "4LN76g9b6I",+ "replyTo": "K2vo08sONs",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Thank you!",+ "comment": "Thank you for your positive assessment of our rebuttal."+ },+ "createdAt": "2026-07-31T14:55:12.449Z",+ "modifiedAt": "2026-11-19T17:09:51.268Z",+ "url": "https://openreview.net/forum?id=GmZxHeBKTq¬eId=4LN76g9b6I",+ "license": "CC-BY-4.0"+}
reviews/openreview/gmzxhebktq/notes/f8hxqykozw.json added
+++ b/reviews/openreview/gmzxhebktq/notes/f8hxqykozw.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "F8hXqyKOZW",+ "replyTo": "2nOwwv0yx9",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to the Area Chair’s Meta-Review",+ "comment": "Thank you for the constructive feedback. We have addressed the four concerns with additional experiments and corresponding analyses, and clarifications, as summarized below:\n\n**1.Hallucination evidence.** In our rebuttal response to **Reviewer oecC’s Question 1 & Limitation 1**, we have added a radiologist-based evaluation involving five radiologists on 50 cases sampled from each of the MIMIC-CXR and IU X-Ray test sets, together with the corresponding results table and analysis. In our rebuttal response to **Reviewer jtfF’s Question 1**, we have also presented this radiologist-based evaluation, together with an analysis of uncertainty errors and the corresponding tabulated experimental results.\n\n**2.Trajectory faithfulness.** In our rebuttal response to **Reviewer jtfF’s Question 1**, we have added an evaluation independent of CheXbert/RadGraph, in which GPT-5.5 and five radiologists audited reasoning trajectories from 50 cases sampled from each of the MIMIC-CXR and IU X-Ray test sets, together with the corresponding results table and analysis. In our rebuttal response to **Reviewer w3ai’s Question 2**, we have clarified how the Dynamic Evolution Loop identifies and corrects teacher-generated trajectories that add, omit, or contradict findings.\n\n**3.Baseline comparability and uncertainty.** In our rebuttal response to **Reviewer jtfF’s Question 3**, we have clarified that Table 3 reports results cited from the original papers and added a controlled comparison by reproducing several SOTA methods under a unified setting. In response to **Reviewer oecC’s Question 3**, we have repeated the experiments in Tables 1–3 using three random seeds and reported the corresponding results in three tables. In response to **Reviewer w3ai’s Question 1**, we have added an analysis explaining why Rep-SFT outperforms several SOTA methods.\n\n**4.Related-work coverage and reproducibility.** In our rebuttal response to **Reviewer oecC’s Question 2 & Limitation 3**, we have expanded the discussion of reasoning-focused RRG methods, together with the corresponding comparison table and analysis. In our rebuttal response to **Reviewer jtfF’s Question 5**, we have also provided detailed PSY-PO construction settings."+ },+ "createdAt": "2026-07-31T12:00:21.285Z",+ "modifiedAt": "2026-11-19T17:09:51.310Z",+ "url": "https://openreview.net/forum?id=GmZxHeBKTq¬eId=F8hXqyKOZW",+ "license": "CC-BY-4.0"+}
reviews/openreview/gmzxhebktq/notes/ipcejtjitd.json added
+++ b/reviews/openreview/gmzxhebktq/notes/ipcejtjitd.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "iPCeJTjItD",+ "replyTo": "j58gTvV352",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer jtfF",+ "content": {+ "comment": "Thank you for the detailed response. I have read it carefully. The new radiologist evaluation, trajectory audit, controlled IU X-Ray comparisons, three-seed results, and additional PSY-PO details address most of my concerns and make me more positive about the paper.\n\nI have one important clarification about the expert evaluation. Did the radiologists have access to the chest X-rays when assessing both the generated reports and the reasoning trajectories? Were the outputs presented blinded to the method and in randomized order? Please also clarify how the five ratings were aggregated and report inter-reader agreement or uncertainty if available. The response says that image-faithfulness was assessed using the reference report as the evaluation basis; if the images were not shown, this should be described as consistency with the reference report rather than image-faithfulness.\n\nFor the final version, please include the complete expert-evaluation protocol and new results, the exact negative-generation prompt, the three-seed results, the controlled baseline setup, and the expanded limitations. Please also soften the SOTA/small-model claims and remove the remaining checklist instruction block as promised. I am not asking for another large experiment; clarification of the existing evaluation protocol and uncertainty from the collected ratings would be sufficient.\n\nSubject to this clarification, my main concerns are largely resolved."+ },+ "createdAt": "2026-07-29T06:50:25.112Z",+ "modifiedAt": "2026-11-19T17:09:51.525Z",+ "url": "https://openreview.net/forum?id=GmZxHeBKTq¬eId=iPCeJTjItD",+ "license": "CC-BY-4.0"+}
reviews/openreview/gmzxhebktq/notes/k2vo08sons.json added
+++ b/reviews/openreview/gmzxhebktq/notes/k2vo08sons.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "K2vo08sONs",+ "replyTo": "p664bxRfcn",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer jtfF",+ "content": {+ "comment": "Thank you for the clarification. My main concerns are resolved, and I will update my assessment accordingly."+ },+ "createdAt": "2026-07-31T13:31:03.905Z",+ "modifiedAt": "2026-11-19T17:09:51.311Z",+ "url": "https://openreview.net/forum?id=GmZxHeBKTq¬eId=K2vo08sONs",+ "license": "CC-BY-4.0"+}
reviews/openreview/gmzxhebktq/notes/nm9ic5xp8m.json added
+++ b/reviews/openreview/gmzxhebktq/notes/nm9ic5xp8m.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "nm9iC5XP8m",+ "replyTo": "JJFC32glXN",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Supplementary Table for Question 2 & Limitation 3 from Reviewer oecC",+ "comment": "For completeness, we supplement our previous rebuttal response to **Reviewer oecC's Question 2 & Limitation 3** with the table below, which presents the MIMIC-CXR and IU X-Ray results of representative reasoning-focused RRG methods. * denotes results reproduced by us.\n\n| Methods | MIMIC-CXR BLEU-4 | MIMIC-CXR METEOR | MIMIC-CXR ROUGE-L | MIMIC-CXR Precision | MIMIC-CXR Recall | MIMIC-CXR F1 | IU X-Ray BLEU-4 | IU X-Ray METEOR | IU X-Ray ROUGE-L |\n| --- | ---: | ---: | ---: | ---: | ---: | ---: | ---: | ---: | ---: |\n| CheXOne [2]\\* | 0.112 | 0.154 | 0.287 | 0.403 | 0.364 | 0.383 | 0.171 | 0.203 | 0.382 |\n| CoMT [4]\\* | 0.106 | 0.134 | 0.247 |0.398 | 0.356 | 0.376 | 0.140 | 0.171 | 0.324 |\n| ORGAN [3] | 0.123 | 0.162 | 0.293 | 0.416 | 0.385 | 0.418 | 0.195 | 0.205 | **0.399** |\n| **Ours** | **0.165** | **0.181** | **0.310** | **0.636** | **0.476** | **0.546** | **0.241** | **0.230** | 0.395 |"+ },+ "createdAt": "2026-07-29T13:21:10.013Z",+ "modifiedAt": "2026-11-19T17:09:51.518Z",+ "url": "https://openreview.net/forum?id=GmZxHeBKTq¬eId=nm9iC5XP8m",+ "license": "CC-BY-4.0"+}
reviews/openreview/gmzxhebktq/notes/p664bxrfcn.json added
+++ b/reviews/openreview/gmzxhebktq/notes/p664bxrfcn.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "p664bxRfcn",+ "replyTo": "iPCeJTjItD",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer jtfF’s Follow-up Questions",+ "comment": "Thank you for the careful follow-up and positive assessment. We clarify the expert-evaluation protocol below:\n\n**1.Access to chest X-rays:** The radiologists were provided with the corresponding chest X-rays when evaluating the generated reports. However, the chest X-rays were not shown when evaluating the reasoning trajectories; only the reasoning trajectories and reference reports were provided. We will clarify these two evaluation settings in the final manuscript.\n\n**2.Blinding and randomization:** Yes. For the 50 randomly selected cases from each dataset, both the compared methods and their corresponding outputs were anonymized, and the outputs were presented to each radiologist in randomized order. The radiologists remained blinded to the generating method throughout the evaluation.\n\n**3.Rating Aggregation:** Thank you for your suggestion. We further clarify the rating aggregation procedure. 5 radiologists independently evaluated the same set of sampled instances. The expert-evaluation comprises four dimensions: Hallucination Severity and Clinical Usefulness for generated reports, and Reasoning Quality and Report-Faithfulness for reasoning trajectories. Since the corresponding chest X-rays were not provided to the radiologists during the reasoning trajectory evaluation, we rename the original Image-Faithfulness metric as Report-Faithfulness. For an evaluated method or ablation variant m, evaluation dimension q, and sampled instance i, we first average the ratings from the 5 radiologists:\n$$\n\\\\bar{s}\\_{i,m}^{(c)}=\\\\frac{1}{5}\\\\sum\\_{r=1}^{5}s\\_{i,m,r}^{(c)}\n$$\nHere, $s\\_{i,r}^{(m,q)}$ denotes the score assigned by radiologist $r$ to the $i$-th sampled instance, either a generated report or a reasoning trajectory, under method or ablation variant $m$ and evaluation dimension $q$.\n\nWe then sum the instance-level mean scores over the $N$ sampled instances and divide by $N$ to obtain the final evaluation score:\n$$\n\\\\bar{s}^{(m,q)}=\\\\frac{1}{N}\\\\sum\\_{i=1}^{N}\\\\bar{s}\\_{i}^{(m,q)}\n$$\nFor the generated-report evaluation, we randomly sampled 50 cases from each of the IU X-Ray and MIMIC-CXR test sets; therefore, N=50 for each dataset. For the reasoning trajectory evaluation, we randomly sampled 100 generated reasoning trajectories; therefore, N=100. \n\n**4. Inter-Reader Agreement:** To assess agreement among the five radiologists, we compute ordinal Krippendorff’s alpha $\\\\alpha^{(m,q)}$ **[c]** separately for each compared method or ablation variant $m$ and each evaluation dimension $q$. A value closer to 1 indicates stronger agreement among the radiologists, whereas $\\\\alpha^{(m,q)}=0$ indicates agreement equivalent to that expected under random ratings. The resulting inter-reader agreement scores are reported in the two tables below:\n|Datasets|Methods|Hallucination Severity Agreement|Clinical Usefulness Agreement|\n|---|---|---:|---:|\n|IU-X-Ray|Baseline|0.672|0.731|\n|IU-X-Ray|+SECR w/o Evo|0.723|0.660|\n|IU-X-Ray|+SECR|0.681|0.670|\n|IU-X-Ray|+PSY-PO|0.708|0.718|\n|IU-X-Ray|COMG+RL|0.659|0.670|\n|IU-X-Ray|R2Gen-Mamba|0.733|0.698|\n|IU-X-Ray|Ours|0.698|0.729|\n|MIMIC-CXR|Baseline|0.716|0.741|\n|MIMIC-CXR|+SECR w/o Evo|0.664|0.670|\n|MIMIC-CXR|+SECR|0.742|0.701|\n|MIMIC-CXR|+PSY-PO|0.703|0.681|\n|MIMIC-CXR|COMG+RL|0.676|0.730|\n|MIMIC-CXR|R2Gen-Mamba|0.729|0.671|\n|MIMIC-CXR|Ours|0.655|0.662|\n\n|Reasoning Stage|Reasoning Quality Agreement|Image Faithfulness Agreement|\n|---|---:|---:|\n|Reasoning Chain **w/o** Evo|0.712|0.748|\n|Reasoning Chain|0.739|0.733|\n\nOverall, the Krippendorff’s alpha values for Hallucination Severity, Clinical Usefulness, Reasoning Quality, and Report-Faithfulness ranged from 0.655–0.742, 0.660–0.741, 0.712–0.739, and 0.733–0.748, respectively. These results indicate moderate inter-reader agreement among the five radiologists across the four evaluation dimensions. \n\n**[c]** Krippendorff, K. Content Analysis: An Introduction to Its Methodology. 4th ed. SAGE Publications, 2018.\n\n**5.Evaluation Terminology and Definition:** We agree that the term “image-faithfulness” is imprecise because the corresponding chest X-rays were not provided when evaluating the SECR reasoning trajectories. The evaluation was based solely on the clinical findings and related descriptions documented in the reference reports. To avoid ambiguity, we will replace “image-faithfulness” with “report-faithfulness,” which measures the consistency between the statements in a reasoning trajectory and the content of the corresponding reference report. We will also clarify its definition and evaluation protocol in the final version.\n\nIn the final version, we will include the complete expert-evaluation protocol, rating aggregation procedure, uncertainty and inter-reader agreement results, the exact negative-generation prompt, the three-seed results, the controlled baseline setup, and the expanded limitations. We will also soften the SOTA/small-model claims and remove the remaining checklist instruction block as promised."+ },+ "createdAt": "2026-07-31T11:30:09.704Z",+ "modifiedAt": "2026-11-19T17:09:51.400Z",+ "url": "https://openreview.net/forum?id=GmZxHeBKTq¬eId=p664bxRfcn",+ "license": "CC-BY-4.0"+}
reviews/openreview/gmzxhebktq/notes/rgmlwzyzt9.json added
+++ b/reviews/openreview/gmzxhebktq/notes/rgmlwzyzt9.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "RgmlwZYZt9",+ "replyTo": "WH1tifIjYl",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Correction to the Response to Reviewer w3ai's Question 2",+ "comment": "Dear Area Chair and Reviewers,\n\nWe sincerely apologize for the incorrect response to **Reviewer w3ai’s Question 2** in our previous rebuttal and would like to provide the corrected response below:\n\n**Corrected response for Reviewer w3ai’s Question 2:** Thank you for the constructive suggestion. Directly internalizing teacher-generated reasoning that contains additional findings, omits findings, or conflicts with the supervision provided by the report GT could indeed introduce noisy supervision and adversely affect subsequent report generation. Importantly, such problematic reasoning trajectories are not directly used as the final supervision for internalization. The Dynamic Evolution Loop first compares the skill-invocation results in the teacher-generated trajectories with the supervision derived from the report GT to identify inconsistent trajectories. It then revises the corresponding RadSkills using the report GT and guides the teacher model to regenerate more accurate reasoning trajectories. The GRG module subsequently internalizes these evolved trajectories, thereby reducing the impact of reasoning noise. As shown in **Appendix Fig. C.8**, as RadSkills progressively self-evolve, the number of detected trajectories with failed skill invocation decreases from 1,272 to 68, corresponding to a cumulative correction rate of 94.7%. This indicates that most identified errors can be successfully corrected. Although a small number of undetected clinical inconsistencies may still remain, their prevalence is limited. In future work, stronger teacher models or additional self-evolution rounds could be adopted to further reduce noise in teacher-generated reasoning trajectories.\n\nFurthermore, we have conducted additional experiments to evaluate the impact of reasoning trajectories generated by teacher models of different scales and using different prompt styles on report generation performance, as shown in the table below. “Concise” denotes a simplified prompt that preserves the task objective and output format while removing detailed generation rules, constraints, and in-context examples, retaining only the core task instructions.\n\n| Teacher Model | Prompt Style | BLEU-4 | METEOR | ROUGE-L | Precision | Recall | F1 |\n| --- | --- | ---: | ---: | ---: | ---: | ---: | ---: |\n| 9B | Ours | **0.241** | **0.230** | 0.395 | **0.603** | 0.551 | **0.576** |\n| 9B | Concise | 0.240 | 0.223 | **0.396** | 0.596 | **0.553** | 0.573 |\n| 4B | Ours | 0.233 | 0.219 | 0.386 | 0.561 | 0.528 | 0.544 |\n| 4B | Concise | 0.238 | 0.221 | 0.388 | 0.572 | 0.519 | 0.544 |"+ },+ "createdAt": "2026-07-30T13:32:50.791Z",+ "modifiedAt": "2026-11-19T17:09:51.518Z",+ "url": "https://openreview.net/forum?id=GmZxHeBKTq¬eId=RgmlwZYZt9",+ "license": "CC-BY-4.0"+}
reviews/openreview/gmzxhebktq/notes/va0pmmatuh.json added
+++ b/reviews/openreview/gmzxhebktq/notes/va0pmmatuh.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "Va0PMMAtUH",+ "replyTo": "KUkT2imP6Q",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Kind Reminder",+ "comment": "Dear Reviewer w3ai,\n\nWe sincerely appreciate your helpful and constructive comments. As the discussion period is nearing the end, we would greatly appreciate it if you could let us know whether our rebuttal addresses your concerns."+ },+ "createdAt": "2026-08-03T13:06:46.979Z",+ "modifiedAt": "2026-11-19T17:09:51.163Z",+ "url": "https://openreview.net/forum?id=GmZxHeBKTq¬eId=Va0PMMAtUH",+ "license": "CC-BY-4.0"+}
reviews/openreview/gmzxhebktq/notes/wd6iswhtow.json added
+++ b/reviews/openreview/gmzxhebktq/notes/wd6iswhtow.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "wd6IsWHtOW",+ "replyTo": "JJFC32glXN",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Kind Reminder",+ "comment": "Dear Reviewer oecC,\n\nWe sincerely appreciate your helpful and constructive comments. As the discussion period is nearing the end, we would greatly appreciate it if you could let us know whether our rebuttal addresses your concerns.\n\nBest Regards,\n\nAuthors"+ },+ "createdAt": "2026-08-03T13:05:46.710Z",+ "modifiedAt": "2026-11-19T17:09:51.262Z",+ "url": "https://openreview.net/forum?id=GmZxHeBKTq¬eId=wd6IsWHtOW",+ "license": "CC-BY-4.0"+}
reviews/openreview/gmzxhebktq/notes/yvvwprwzrt.json added
+++ b/reviews/openreview/gmzxhebktq/notes/yvvwprwzrt.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "YVvWpRwZrT",+ "replyTo": "JJFC32glXN",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Supplementary MIMIC-CXR Error-Bar Results for Tables 1–2 in Response to Reviewer oecC's Question 3",+ "comment": "For completeness, we supplement our previous rebuttal response to Reviewer oecC's Question 3 with the corresponding MIMIC-CXR Error-Bar Results for Tables 1 and 2, as presented below.\n\n| Different Modules |MIMIC-CXR BLEU-4 |MIMIC-CXR METEOR |MIMIC-CXR ROUGE |MIMIC-CXR Precision |MIMIC-CXR Recall |MIMIC-CXR F1 |\n| --- | ---: | ---: | ---: | ---: | ---: | ---: |\n| Baseline | 0.106 ± 0.003 | 0.138 ± 0.002 | 0.256 ± 0.003 | 0.585 ± 0.005 | 0.333 ± 0.003 | 0.425 ± 0.003 |\n| SECR w/o Evo | 0.126 ± 0.003 | 0.160 ± 0.002 | 0.287 ± 0.003 | 0.621 ± 0.003 | 0.441 ± 0.004 | 0.516 ± 0.003 |\n| SECR | 0.146 ± 0.003 | 0.171 ± 0.004 | 0.292 ± 0.001 | 0.630 ± 0.004 | 0.468 ± 0.007 | 0.537 ± 0.003 |\n| PSY-PO | 0.155 ± 0.003 | 0.175 ± 0.003 | 0.303 ± 0.004 | 0.617 ± 0.003 | 0.446 ± 0.003 | 0.518 ± 0.003 |\n| **Ours** | **0.165 ± 0.003** | **0.181 ± 0.002** | **0.310 ± 0.004** | **0.636 ± 0.008** | **0.476 ± 0.010** | **0.546 ± 0.007** |\n\n| Strategy |MIMIC-CXR BLEU-4 |MIMIC-CXR METEOR |MIMIC-CXR ROUGE-L |MIMIC-CXR Precision |MIMIC-CXR Recall |MIMIC-CXR Clinical F1 |\n|---|---:|---:|---:|---:|---:|---:|\n| Rep SFT | 0.106 ± 0.003 | 0.138 ± 0.002 | 0.256 ± 0.003 | 0.585 ± 0.005 | 0.333 ± 0.003 | 0.425 ± 0.003 |\n| Rea+Rep SFT | 0.102 ± 0.003 | 0.123 ± 0.004 | 0.221 ± 0.005 | 0.456 ± 0.006 | 0.313 ± 0.002 | 0.371 ± 0.007 |\n| Rep→Rea SFT | 0.108 ± 0.005 | 0.115 ± 0.002 | 0.214 ± 0.004 | 0.436 ± 0.008 | 0.304 ± 0.009 | 0.358 ± 0.006 |\n| **Ours** | **0.146 ± 0.003** | **0.171 ± 0.004** | **0.292 ± 0.001** | **0.630 ± 0.004** | **0.468 ± 0.007** | **0.537 ± 0.003** |"+ },+ "createdAt": "2026-07-31T11:48:29.657Z",+ "modifiedAt": "2026-11-19T17:09:51.899Z",+ "url": "https://openreview.net/forum?id=GmZxHeBKTq¬eId=YVvWpRwZrT",+ "license": "CC-BY-4.0"+}