potentialpaper

Less Evidence, Better Answering: Gain-Aware Minimal Evidence Subset Selection for Medical QA

Import NeurIPS 2026 submission PsPjtMRFBs: 8 notes

@openreview[bot] · 2026-11-22 17:56 UTC · cdd99589cf53

Evidence

.gitattributes added

+++ b/.gitattributes
@@ -0,0 +1,10 @@
+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),
+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.
+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text
+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text
+/thumbnail.png filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text
+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text
+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text

.potentialpaper/metadata.json added

+++ b/.potentialpaper/metadata.json
@@ -0,0 +1,24 @@
+{
+ "layout": 5,
+ "identifiers": [
+ {
+ "scheme": "openreview",
+ "value": "PsPjtMRFBs"
+ }
+ ],
+ "title": "Less Evidence, Better Answering: Gain-Aware Minimal Evidence Subset Selection for Medical QA",
+ "authors": [
+ "Songyue Guo",
+ "Zhao CHEN",
+ "Caleb Chen Cao",
+ "Lei Chen"
+ ],
+ "abstract": "Evidence-grounded medical question answering requires not only accurate answers, but also precise, verifiable, and clinically trustworthy evidence. Existing medical RAG systems typically retrieve top-\\(k\\) chunks according to item-wise relevance. Although this design improves recall, it does not explicitly optimize whether the selected evidence set is compact, sufficient, and decision-critical. In this paper, we study medical evidence-grounded QA from a different perspective: instead of retrieving evidence without optimization, the evidence-grounded medical QA system should identify a compact sufficient subset of high-density evidence snippets. We propose **MEGA**, a gain-aware framework for compact supporting medical evidence selection. MEGA first expands clinical queries into complementary subqueries and performs hybrid retrieval to construct a recall-oriented candidate evidence pool. It then introduces hidden-state **Information Gain Scoring**, which uses a frozen LLM to estimate whether each candidate snippet contributes new answer-relevant information beyond surface relevance. Finally, MEGA formulates evidence selection as a budgeted utility maximization problem and proposes an **FPTAS selector** to identify a compact evidence subset under an explicit token budget. We further construct two evidence-grounded medical QA benchmarks, CRC-EvidenceQA and Med-EvidenceQA, to evaluate both answer quality and evidence grounding. Across three LLM backbones and five medical RAG baselines, MEGA consistently achieves the best results, improving over the second-best baseline by \\(8.8\\%\\) on average in answer quality and 38.8\\% on average in evidence F1. Ablation studies and blinded clinical expert evaluation further validate its robustness and clinical relevance.",
+ "year": 2026,
+ "venue": "NeurIPS 2026",
+ "source": "openreview",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}

community/10-tl-dr.md added

+++ b/community/10-tl-dr.md

community/20-summary.md added

+++ b/community/20-summary.md

community/30-why-it-matters.md added

+++ b/community/30-why-it-matters.md

community/40-critique.md added

+++ b/community/40-critique.md

community/50-errata.md added

+++ b/community/50-errata.md

community/60-reproductions.md added

+++ b/community/60-reproductions.md

community/70-follow-ups.md added

+++ b/community/70-follow-ups.md

owners/10-tl-dr.md added

+++ b/owners/10-tl-dr.md

owners/20-overview.md added

+++ b/owners/20-overview.md

owners/30-results.md added

+++ b/owners/30-results.md

owners/40-demos.md added

+++ b/owners/40-demos.md

owners/50-code-and-data.md added

+++ b/owners/50-code-and-data.md

owners/60-talks.md added

+++ b/owners/60-talks.md

prek.toml added

+++ b/prek.toml
@@ -0,0 +1,36 @@
+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.
+# The site checks every push again; these catch mistakes before you commit. The same on every page.
+
+[[repos]]
+repo = "builtin"
+hooks = [
+ { id = "check-json" },
+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },
+ { id = "end-of-file-fixer", exclude = '^demos/' },
+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },
+ { id = "check-case-conflict" },
+ { id = "check-illegal-windows-names" },
+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },
+]
+
+# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).
+[[repos]]
+repo = "https://github.com/python-jsonschema/check-jsonschema"
+rev = "0.39.0"
+hooks = [
+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },
+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },
+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },
+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },
+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },
+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },
+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },
+]
+
+# Sections formatted the way the web editor formats them.
+[[repos]]
+repo = "https://github.com/rbubley/mirrors-prettier"
+rev = "v3.9.9"
+hooks = [
+ { id = "prettier", files = '^(owners|community)/.*\.md$' },
+]

reviews/openreview/pspjtmrfbs/forms.json added

+++ b/reviews/openreview/pspjtmrfbs/forms.json
@@ -0,0 +1,227 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ },
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "quality",
+ "clarity",
+ "significance",
+ "originality"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 6
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 5
+ },
+ {
+ "key": "quality",
+ "label": "Quality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "clarity",
+ "label": "Clarity",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "significance",
+ "label": "Significance",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "originality",
+ "label": "Originality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "contribution_type",
+ "label": "Contribution type",
+ "type": "choice"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "strengths_and_weaknesses",
+ "label": "Strengths and weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions",
+ "label": "Questions",
+ "type": "text"
+ },
+ {
+ "key": "limitations",
+ "label": "Limitations",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ },
+ {
+ "key": "paper_formatting_concerns",
+ "label": "Formatting concerns",
+ "type": "text"
+ },
+ {
+ "key": "ethical_concerns",
+ "label": "Ethical concerns",
+ "type": "choice"
+ },
+ {
+ "key": "code_of_conduct_acknowledgement",
+ "label": "Code of conduct",
+ "hidden": true
+ },
+ {
+ "key": "responsible_reviewing_acknowledgement",
+ "label": "Responsible reviewing",
+ "hidden": true
+ }
+ ]
+ },
+ "Rebuttal": {
+ "label": "Rebuttal",
+ "fields": [
+ {
+ "key": "rebuttal",
+ "label": "Rebuttal",
+ "type": "text"
+ }
+ ]
+ },
+ "Ethics_Review": {
+ "label": "Ethics review",
+ "fields": [
+ {
+ "key": "scope_of_ethics_concerns",
+ "label": "Scope",
+ "type": "choice"
+ },
+ {
+ "key": "ethics_review",
+ "label": "Ethics review",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/pspjtmrfbs/notes/4yl6d6crei.json added

+++ b/reviews/openreview/pspjtmrfbs/notes/4yl6d6crei.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "4yL6d6cReI",
+ "replyTo": null,
+ "kind": "meta_review",
+ "invitation": "Meta_Review",
+ "signature": "Area Chair 52tN",
+ "content": {
+ "metareview": "**Summary:** \nThis paper proposes MEGA, a medical question answering framework that selects compact and decision relevant evidence rather than retaining independently ranked top k passages. The framework combines subquery based hybrid retrieval, hidden state Information Gain Scoring, and an FPTAS selector that optimizes evidence utility under a token budget, while also introducing CRC-EvidenceQA and Med-EvidenceQA for evaluating answer quality and evidence grounding. Experiments across three language model backbones and five medical RAG baselines report substantial improvements in answer quality and Evidence F1 with fewer evidence tokens, supported by ablation studies and clinician evaluation. \n\n**Strengths:** \nReviewers 1JmM, q6S3, and RrbL agree that the paper addresses an important and clearly motivated problem in high stakes medical question answering through a novel shift from passage ranking to compact evidence subset optimization. They also recognize the clear presentation, comprehensive technical pipeline, strong empirical results across multiple models and datasets, detailed ablations, and inclusion of clinician based evaluation. \n\n**Weaknesses:** \nReviewers 1JmM, q6S3, and RrbL question whether the hidden state information gain signals generalize across different frozen models, architectures, middle layer choices, and judge models. Reviewers 1JmM and q6S3 highlight that the considerable inference latency and hardware requirements weaken the claimed efficiency benefits and leave practical clinical integration insufficiently addressed. Reviewer q6S3 notes that the cross layer coherence and gradient signals appear heuristic, provide relatively limited gains, and lack sufficient theoretical or architecture independent validation. Reviewers q6S3 and RrbL request stronger analysis of the selection mechanism, including comparisons with greedy selection using identical IGS scores, sensitivity under tighter token budgets, clearer Evidence F1 definitions, and more informative qualitative success and failure cases. \n\n**Response Direction:** \nA convincing response should demonstrate robustness across scorer and judge families, provide latency and deployment analyses, justify each IGS component, and add controlled greedy, budget sensitivity, metric clarification, and qualitative failure case evaluations.\n\n---\n\nThe authors substantially addressed the flagged technical concerns through new robustness tests, budget-matched and greedy-selector comparisons, latency and deployment clarifications, and failure-case analysis; in discussion, RrbL found the clarifications satisfactory, q6S3 raised the rating from 3 to 4 while retaining concerns about the paper’s framing, and 1JmM provided no further feedback.\n\nI recommend a borderline accept because the paper presents a well-motivated and technically solid approach to compact evidence subset selection, supported by strong multi-model, multi-dataset, ablation, and clinician evaluations, while the remaining concerns about the “less evidence” framing, inference latency, and clinical deployment temper rather than outweigh its contributions."
+ },
+ "createdAt": "2026-07-22T18:44:23.971Z",
+ "modifiedAt": "2026-11-18T15:21:12.691Z",
+ "url": "https://openreview.net/forum?id=PsPjtMRFBs&noteId=4yL6d6cReI",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/pspjtmrfbs/notes/csmpylkxvm.json added

+++ b/reviews/openreview/pspjtmrfbs/notes/csmpylkxvm.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "cSmpyLKxvM",
+ "replyTo": "YkuWMbn9yF",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "We sincerely thank Reviewer 1JmM for the constructive feedback and recognition of the paper’s clarity, significance, and novel formulation. We address all concerns below.\n\n----\n\n#### ***Q1 & L1 : Can the authors provide qualitative success and failure cases for the proposed method MEGA? And discussions about why? And also the influence of each component?***\n\nA1: Thanks for your valuable suggestions. We inspected the experimental logs and categorized cases by their originating stage. We will add representative success/failure cases and component-wise analysis to Appendix E.4.\n\n***Our failure analysis*** identifies two modes:\n\n| Failure mode | Stage | Description | Percentage |\n| ------------------------ | ------------------------ | ------------------------------------------------------------ | ---------- |\n| Candidate recall failure | Hybrid Retrieval | Decision-critical gold evidence is absent from the candidate pool and cannot be recovered downstream. | 76% |\n| IGS scoring failure | Information Gain Scoring | A near-miss candidate with similar terms receives an overly high score, while a decision-critical snippet is underestimated. | 24% |\n\nAmong inspected failures, 76% involve candidate recall and 24% IGS misranking; categories may overlap.\n\n#### Qualitative failure case 1: Missing evidence in the candidate pool $C$\n\nFor QID `13` in CRC-EvidenceQA (`\"What toxicity of oxaliplatin requires the closest clinical monitoring?\"`), a supported answer requires two complementary pieces of evidence: `E1: oxaliplatin is associated with acute and delayed peripheral sensory neuropathy...`; and `E2: persistent or cumulative neuropathy may impair daily functioning...`. However, the retriever includes only `E1` in $C$, so neither IGS nor FPTAS can recover `E2`. MEGA selects `E1`, but the subset remains insufficient.\n\n#### Qualitative failure case 2: Near-miss evidence receives a high IGS score\n\nFor QID `covid_qa_50` in Med-EvidenceQA, `\"How was cross-reaction detection determined?\"`, the gold evidence states that `detection was conducted by applying JEV, YF, and DV cultures`. IGS instead favors `the proper spotting concentration was determined by minimizing cross-reaction...`. Although the snippets use similar terms, only the gold evidence directly answers the question; the second concerns a different experimental step. IGS overestimates the near-miss, so FPTAS retains it under the budget and the generated answer gives the wrong procedure.\n\n#### Qualitative success case : \nIn one success case shown in Figure 1 (QID `28` in CRC-EvidenceQA), the query asks: `\"For MSI-H/dMMR metastatic CRC, what is the preferred first-line therapy?\"` The candidate pool contains directly relevant, partially relevant, and redundant evidence. **IGS** ranks the evidence matching all decision-critical conditions highest, while lowering partially relevant candidates. The **FPTAS selector** then removes redundant snippets that add little coverage but consume tokens. MEGA therefore retains a compact evidence subset sufficient to support the correct answer. This case shows that IGS filters partially applicable evidence, whereas FPTAS reduces redundancy under the token budget.\n\n---\n\n#### ***Q2 & L2: Can the authors show how robust the information gain score is to the choice of the frozen LLM and judge model?***\n\n**A2:** We conducted additional experiments to evaluate (1) IGS across frozen scorer families and scales and (2) robustness to the judge LLM. We use the Appendix E.3.1 setting: 100 CRC-EvidenceQA and 200 Med-EvidenceQA examples (100 PubMedQA and 100 COVID-QA), with GPT-5.1 as the default judge.\n\n#### Robustness to the frozen scorer LLM.\n\nWe evaluate scorer LLMs from three model families: Qwen, Llama, and Mistral, and parameter scales ranging from 4B to 32B.\n\n> **Table 1. Robustness to the choice of the frozen scorer model.** kp is short for key-point coverage.\n\n| Frozen scorer | Params | kp-AUROC | kp-Spearman | Ans. Quality | Evi. F1 | Time |\n| :---: | :---: | ---: | ---: | ---: | ---: | ---: |\n| Qwen3-8B | 8B | 0.77 | 0.66 | 8.74 | 84.6 | 1.0 $\\times$ |\n| Qwen3-4B | 4B | 0.57 | 0.54 | 6.38 | 66.4 | 0.7 $\\times$ |\n| Qwen3-32B | 32B | 0.79 | 0.68 | 8.80 | 85.1 | 3.7 $\\times$ |\n| Llama-3.1-8B-Instruct | 8B | 0.75 | 0.66 | 8.69 | 83.9 | 1.1 $\\times$ |\n| Mistral-7B-v0.1 | 7B | 0.74 | 0.63 | 8.52 | 83.2 | 0.9 $\\times$ |\n\nIGS generalizes consistently across the different LLM families, which obtain similar AUROC $0.74–0.77$, Spearman $0.63–0.66$, answer quality $8.52–8.74$, and Evidence F1 $83.2–84.6$. In particular, replacing Qwen3-8B with Llama-3.1-8B changes answer quality by only 0.05 and Evidence F1 by 0.7 points. The tested 4B scorer degrades substantially, suggesting insufficient capacity for reliable utility estimation. In contrast, scaling from 8B to 32B improves answer quality by only 0.06 and Evidence F1 by 0.5 points, while increasing runtime to $3.7\\times$. Therefore, we use an 8B scorer for the best reliability–cost balance. \n\n#### Robustness to the judge LLM.\n\nWe test whether Figure 3 depends on the relevance judge LLM by fixing the candidate pools and all IGS/reranker scores, re-annotating relevance with three LLMs under the same prompt, and recomputing per-question AUROC and Spearman correlation.\n\n> **Table 2. Robustness across relevance judges.**\n\n| Relevance Judge | Rel. Rate $%$ | Reranker AUROC | IGS AUROC | $\\Delta$ AUROC | Reranker $\\rho$ | IGS $\\rho$ | $\\Delta\\rho$ |\n| ------------------ | ------------: | -------------: | --------: | -------------: | --------------: | ---------: | -----------: |\n| GPT-5.1 $Original$ | 44.8 | 0.65 | 0.63 | −0.02 | 0.55 | 0.58 | +0.03 |\n| DeepSeek-V4-Flash | 46.2 | 0.64 | 0.63 | −0.01 | 0.54 | 0.57 | +0.03 |\n| Gemini-3.6-Flash | 43.9 | 0.66 | 0.64 | −0.02 | 0.56 | 0.60 | +0.04 |\n| **Average** | **45.0** | **0.65** | **0.63** | **−0.02** | **0.55** | **0.58** | **+0.03** |\n\nResults are stable across different judge LLMs. The relevance rate ranges from 43.9% to 46.2%, and all metrics vary by at most 0.03. The reranker retains a small advantage in relevance AUROC, while IGS consistently achieves higher rank correlation. Together with its larger gains on key-point coverage in Figure 3, this shows that IGS captures both topical relevance and decision-critical evidence utility. We will add these results to Appendix E.3.\n\n---\n\n#### ***Q3 & L3: Can MEGA be integrated into practical scenarios, given the high latency?***\n\nA3: Although MEGA requires approximately **32.0 s** to complete the full response, its average time to first token (TTFT) is approximately **17.3 s**, comparable to the **14.15 ± 2.91 s response-initiation time reported for OpenEvidence**. Thus, with streaming generation, MEGA provides comparable user-perceived responsiveness.\n\nAs reported in Appendix D.2, our original latency measures the complete pipeline, from receiving the query until all answer tokens have been generated. Thus, the 32.0 s includes both evidence processing and full-answer generation. In practical deployment, streaming allows users to begin reading after approximately **17.3 s**, without waiting for the full response.\n\n> **Table 3. Stage-wise latency of MEGA.**\n\n| Stage | Average latency | \n|---|---:|\n| Hybrid retrieval | 2.9 s | \n| IGS computation | 14.4 s |\n| FPTAS selection | 0.008 s |\n| Answer generation | 14.7 s | \n| **Time to first token** | **17.3 s** |\n| **Full-response latency** | **32.0 s** | \n\nMost latency comes from IGS and answer generation. The latter takes 14.7 s because MEGA generates detailed, evidence-grounded responses averaging approximately 1,300 tokens, corresponding to an effective GPT-4.1 output rate of about 88 tokens/s.\n\n**Hardware requirements.** The 4-A800 node used in our experiments is not a deployment requirement. We used four A800 80GB GPUs for experimental convenience and throughput because the evaluation repeatedly loaded multiple embedding models, rerankers, scorer LLMs, answer-generation backbones, and baseline systems. For single-query inference, the complete Qwen3-8B-based IGS module runs on **one A800 80GB GPU**, while FPTAS adds negligible memory and computation.\n\nOverall, MEGA introduces 14.4 s of evidence-scoring overhead in exchange for more accurate and better-grounded evidence selection, while maintaining an initial response time comparable to OpenEvidence. We consider it practical for non-emergency clinical consultation and evidence review. We will add this analysis to the Limitations and Discussion section.\n\n---\n\n#### ***Q4: Can the authors discuss and compare with existing information-gain-based methods [1,2]?***\n\nA4: Thank you for pointing out these important connections. We agree that MEGA shares with Information Bottleneck $IB$ and Information Pursuit $IP$ the general principle of retaining compact yet prediction-sufficient information.\n\nHowever, their formulations differ substantially. IB learns a compressed latent representation by balancing $I(X;\\tilde{X})$ and $I(\\tilde{X};Y)$. IP sequentially selects user-defined binary queries according to their conditional mutual information with the prediction target. In contrast, MEGA performs inference-time selection over retrieved textual evidence. It uses frozen-LLM hidden-state changes as an operational utility proxy and jointly selects verifiable evidence sentences under a token budget using FPTAS. \n\nThus, MEGA’s contribution is its operationalization for evidence-grounded medical QA through model-conditioned evidence scoring, explicit token-cost modeling, and globally optimized selection of a directly citable evidence subset. We will clarify these connections and distinctions in the related work section."
+ },
+ "createdAt": "2026-07-27T15:18:42.119Z",
+ "modifiedAt": "2026-11-18T17:15:41.277Z",
+ "url": "https://openreview.net/forum?id=PsPjtMRFBs&noteId=cSmpyLKxvM",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/pspjtmrfbs/notes/kfbfbd2og6.json added

+++ b/reviews/openreview/pspjtmrfbs/notes/kfbfbd2og6.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "kFBfbd2OG6",
+ "replyTo": "WcGsQPgE8E",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "Dear Reviewer q6S3,\n\nThank you for your detailed and constructive feedback. Below, we respond to each comment.\n\n---\n\n#### ***Q1: Large hidden-state shifts may also be caused by misleading or contradictory medical evidence. How does IGS distinguish useful information gain from disruptive noise rather than assuming that larger shifts imply higher utility?***\n\n**A1:** We thank the reviewer for raising this important point. We agree that a large hidden-state shift alone cannot guarantee factual correctness. However, this is not the assumption of IGS. As stated in `Sec. 3.2, Line 158`, IGS is an evidence-utility estimator under imperfect retrieval, not a factual verification module.\n\nLet the candidate pool be $C=C^+\\cup C^-$, where $C^+$ and $C^-$ denote supporting and misleading evidence, respectively. Since no retriever, reranker, or LLM filter can remove all noise, $\\epsilon_R=P(c\\in C^-\\mid c\\in C)>0$. Therefore, the goal of IGS is not to achieve zero error but to avoid noise amplifying noise: $\\epsilon_S=P(c\\in C^-\\mid c\\in S)\\leq\\epsilon_R$.\n\nUnder the weak assumption $P(s(c)>\\tau\\mid c\\in C^+)\\geq P(s(c)>\\tau\\mid c\\in C^-)$, IGS reduces the expected noise proportion after scoring. Figure 3 empirically supports this assumption. Although the reranker is slightly better on general relevance, IGS aligns substantially better with key-point coverage, indicating that it captures answer-relevant utility beyond surface relevance.\n\n---\n\n#### ***Q2 & L1: Discuss the tradeoff between token reduction and time inefficiency.***\n\n**A2:** The **32.0s** reported in `Appendix E.3.2` is end-to-end latency, not IGS-only cost. Stage-wise profiling gives 2.9s for retrieval, 14.4s for IGS, 0.008s for FPTAS, and 14.7s for answer generation, yielding approximately 30–32s total latency and **17.3s TTFT**. OpenEvidence reports approximately **14.15±2.91s** response initiation. Thus, streaming of MEGA can provide comparable user-perceived responsiveness.\n\n> **Table 1. Stage-wise latency of MEGA.**\n\n| Stage | Average latency |\n| ------------------------- | --------------: |\n| Hybrid retrieval | 2.9 s |\n| IGS computation | 14.4 s |\n| FPTAS selection | 0.008 s |\n| Answer generation | 14.7 s |\n| **Time to first token** | **17.3 s** |\n| **Full-response latency** | **32.0 s** |\n\nMoreover, MEGA trades 14.4s of scoring overhead for 35.6% fewer evidence tokens and substantially stronger evidence grounding. We agree that token efficiency does not imply latency efficiency. We will replace “efficiency” with **evidence-token efficiency**, report the latency decomposition, and clarify that MEGA targets non-emergency evidence review rather than latency-critical applications.\n\n---\n\n#### ***Q3: Cross-Layer Coherence and Cross-Layer Gradient lack sufficient theoretical and empirical justification. Are they heuristic signals, and do their limited ablation gains justify their computational cost?***\n\n**A3:** Cross-Layer Coherence and Cross-Layer Gradient **are not arbitrary heuristics, but theory-motivated geometric statistics describing evidence-induced representation trajectories**.\n\nLet $\\hat{\\Delta}_i^{(\\ell)}=\\Delta_i^{(\\ell)}/\\|\\Delta_i^{(\\ell)}\\|_2$. Cross-Layer Coherence can be written as \n\n$g_{i3}=1-\\frac{1}{4(|\\mathcal L|-1)}\\sum_{\\ell\\in\\mathcal L^-}\\left\\|\\hat{\\Delta}_i^{(\\ell+1)}-\\hat{\\Delta}_i^{(\\ell)}\\right\\|_2^2.$\n\nIt is the complement of the discrete directional variation across layers: isolated or oscillatory perturbations obtain low coherence, whereas persistent updates obtain high coherence. Cross-Layer Gradient is the positive ordinary-least-squares trend $g_{i4}=\\left[\\frac{\\operatorname{Cov}(z_\\ell,a_\\ell(c_i))}{\\operatorname{Var}(z_\\ell)}\\right]_+,$\nwhich measures whether the evidence effect strengthens toward deeper semantic layers rather than appearing as a shallow spike. **These designs are motivated by prior findings** [1] [2] [3] that intermediate hidden states encode knowledge-boundary and factuality information, and that **cross-layer cosine trajectories reveal feature persistence and representation development**. \n\n**Empirical contribution.** In Figure 3, Coherence and Gradient individually achieve key-point AUROC of 0.74/0.76 and Spearman $\\rho$ of 0.58/0.60, exceeding the reranker’s 0.60 AUROC and 0.42 $\\rho$. Their smaller drop-one ablation gaps are expected because the four dimensions are correlated. Removal measures unique conditional contribution, whereas Figure 3 measures standalone informativeness.\n\n**Computational overhead.** Neither signal requires additional LLM forward passes. After hidden-state extraction, Coherence costs $O(|\\mathcal L|d)$ adjacent-vector operations and Gradient costs $O(|\\mathcal L|)$ scalar regression, negligible relative to the 12.4s frozen-model forward stage. We will add this geometric interpretation and computational analysis.\n\n[1] Ni et al., *Towards Fully Exploiting LLM Internal States to Enhance Knowledge Boundary Perception*, ACL 2025. \n[2] Laptev et al., *Analyze Feature Flow to Enhance Interpretation and Steering in Language Models*, ICML 2025. \n[3] Jiang et al., *Tracing Representation Progression: Analyzing and Enhancing Layer-Wise Similarity*, ICLR 2025.\n\n---\n\n#### ***Q4: Furthermore, the robustness of these signals remains unproven in architectures beyond Qwen.***\n\n**A4:** We evaluate frozen scorers from Qwen, Llama, and Mistral, spanning 4B–32B parameters, using the Appendix E.3.1 setting: 100 CRC-EvidenceQA and 200 Med-EvidenceQA examples, with GPT-5.1 as judge.\n\n> **Table 2. Robustness to the frozen scorer model.**\n\n| Frozen scorer | Params | AUROC | Spearman | Ans. Quality | Evi. F1 |\n| :-------------------- | -----: | ----: | -------: | -----------: | ------: |\n| Qwen3-8B | 8B | 0.77 | 0.66 | 8.74 | 84.6 |\n| Qwen3-4B | 4B | 0.57 | 0.54 | 6.38 | 66.4 |\n| Qwen3-32B | 32B | 0.79 | 0.68 | 8.80 | 85.1 |\n| Llama-3.1-8B-Instruct | 8B | 0.75 | 0.66 | 8.69 | 83.9 |\n| Mistral-7B-v0.1 | 7B | 0.74 | 0.63 | 8.52 | 83.2 |\n\nThe tested 7B–8B families achieve similar results. Replacing Qwen3-8B with Llama-3.1-8B changes answer quality by only 0.05 and Evidence F1 by 0.7. Scaling to Qwen3-32B improves answer quality by only 0.06 and Evidence F1 by 0.5 while substantially increasing runtime. Qwen3-4B degrades markedly, suggesting insufficient capacity for reliable utility estimation. Thus, IGS generalizes across the different LLM architectures.\n\n---\n\n#### ***Q5: Equation (1) uses both soft length penalties and a manually tuned hard budget $B$. Are these constraints redundant, and which one primarily controls evidence compactness?***\n\n**A5:** The two constraints serve different roles. The hard budget\n\n$\\sum_{c_i\\in S}t_i\\leq B$\n\ndefines the feasible context window and guarantees that evidence never exceeds a deployment-specified limit. In contrast, penalty term $-\\gamma-\\mu t_i$ controls preferences among feasible subsets: $\\gamma$ discourages unnecessary evidence units, while $\\mu$ penalizes long snippets. Thus, $B$ controls worst-case length, whereas the penalties encourage compactness even when the budget is not saturated.\n\nWe conduct a controlled ablation on the same 300 examples, fixing the candidate pools, Qwen3-8B scorer, GPT-4.1 backbone, and $\\epsilon=0.1$. For **Hard $B$ only**, we set $\\gamma=\\mu=0$; for **Penalties only**, we retain $\\gamma$ and $\\mu$ but set $B=\\sum_i t_i$, making the hard constraint inactive.\n\n> **Table 3. Distinct roles of $B$ and the soft penalties.**\n\n| Setting | Avg. tokens $\\downarrow$ | Queries exceeding 1,043 tokens $\\downarrow$ | Evi. F1 $\\uparrow$ | Ans. Quality $\\uparrow$ |\n| -------------------- | -----------------------: | ------------------------------------------: | -----------------: | ----------------------: |\n| Hard $B$ only | 1,016 | 0% | 81.9 | 8.57 |\n| Penalties only | 635 | 11.3% | 79.5 | 8.28 |\n| Hard $B$ + penalties | **612** | **0%** | **84.6** | **8.74** |\n\nThe hard constraint alone admits more weakly useful evidence, whereas penalties alone cannot guarantee the context limit. Their combination is therefore complementary, not redundant. We will also clarify that $B$ is selected once on development data and fixed during testing.\n\n---\n\n#### ***Q6: The Evidence F1 calculation and comparison are insufficiently explained, especially for Context+LLM, and important evaluation details are mostly left to the appendix.***\n\n**A6:** We apologize for the ambiguity. Evidence F1 is defined in `Line 265` and computed identically for all methods by comparing selected evidence $S$ with the gold set $G$:\n\n$P=\\frac{|S\\cap G|}{|S|},\\quad R=\\frac{|S\\cap G|}{|G|},\\quad F_1=\\frac{2PR}{P+R}.$\n\nFor Context+LLM, although the full context is provided as input, $S$ contains only evidence cited in the final answer; the entire input context is not treated as selected evidence. Thus, all methods use the same criterion. We will move this definition and other critical evaluation details into the main experimental setup.\n\n---\n\n#### ***Q7: Improve readability for Fig. 3 and Fig. 4.***\n\n**A7:** We agree. For Figure 3, we will increase spacing and remove overlapping numerical labels. For Figure 4, we will separate the datasets into individual panels, adjust marker placement, and label only Pareto-optimal points. These revisions improve readability without changing the results.\n\n---\n\nThank you again for your careful review and constructive suggestions, which helped us improve both the analysis and presentation of the paper."
+ },
+ "createdAt": "2026-07-28T10:49:51.823Z",
+ "modifiedAt": "2026-11-18T17:15:42.205Z",
+ "url": "https://openreview.net/forum?id=PsPjtMRFBs&noteId=kFBfbd2OG6",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/pspjtmrfbs/notes/shz9p1yit3.json added

+++ b/reviews/openreview/pspjtmrfbs/notes/shz9p1yit3.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "ShZ9p1Yit3",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer RrbL",
+ "content": {
+ "summary": "This work addresses the central challenge of redundancy and noise in medical retrieval-augmented generation (RAG), where standard top-k retrieval often fails to provide a compact, decision-critical evidence set. The authors propose MEGA, a framework that transforms evidence retrieval into a budgeted subset selection problem. MEGA employs sub-query expansion for recall, an Information Gain Scoring (IGS) mechanism using frozen LLM hidden states to estimate evidence utility, and a Fully Polynomial-Time Approximation Scheme (FPTAS) to optimize the evidence subset under a token budget. The claims of the paper are that this gain-aware selection improves both answer quality and evidence grounding while reducing token overhead. Evaluation on the new CRC-EvidenceQA and Med-EvidenceQA benchmarks across multiple LLM backbones shows significant improvements in Evidence F1 and answer metrics compared to five RAG baselines.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "I found this to be a well written paper that addresses a well defined problem in an intelligent and rigorous manner. It was probably the most well written paper I reviewed for this year's conference.",
+ "quality": 4,
+ "clarity": 4,
+ "significance": 4,
+ "originality": 3,
+ "questions": "1. The IGS mechanism relies on hidden states of a frozen LLM to estimate utility. How sensitive is the performance to the choice of the 'middle layers' or the specific frozen model used, and does the information gain signal generalize across different model architectures or is it tightly coupled to the scoring model's internal representations?\n2. The token budget B is tuned on a development split. Since B is a critical hyperparameter for the compactness claim, how does the performance vary across different budget constraints? Specifically, is there a threshold where reducing the budget significantly degrades answer quality, and how does MEGA's Pareto frontier compare to baselines when the budget is extremely tight?\n3. The paper compares MEGA against several RAG baselines, but does not explicitly compare the FPTAS selector against a simple greedy selection based on the same IGS scores. Could the authors provide a comparison between Greedy(IGS) and FPTAS(IGS) to clarify if the optimization complexity is providing the observed gains over a simpler heuristic?",
+ "limitations": "Yes",
+ "rating": 5,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "I have no",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "I thought this was a well written paper on a topic of high importance to medicine. The authors have improved their manuscript through the review process."
+ },
+ "createdAt": "2026-06-24T16:03:41.399Z",
+ "modifiedAt": "2026-11-18T13:39:15.091Z",
+ "url": "https://openreview.net/forum?id=PsPjtMRFBs&noteId=ShZ9p1Yit3",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/pspjtmrfbs/notes/stmwstmgpm.json added

+++ b/reviews/openreview/pspjtmrfbs/notes/stmwstmgpm.json
@@ -0,0 +1,19 @@
+{
+ "schema": "review/1",
+ "id": "STmwstmgpm",
+ "replyTo": null,
+ "kind": "decision",
+ "invitation": "Decision",
+ "signature": "Program Chairs",
+ "content": {
+ "title": "Paper Decision",
+ "decision": "Accept (poster)",
+ "comment": "",
+ "metareview": "**Summary:** \nThis paper proposes MEGA, a medical question answering framework that selects compact and decision relevant evidence rather than retaining independently ranked top k passages. The framework combines subquery based hybrid retrieval, hidden state Information Gain Scoring, and an FPTAS selector that optimizes evidence utility under a token budget, while also introducing CRC-EvidenceQA and Med-EvidenceQA for evaluating answer quality and evidence grounding. Experiments across three language model backbones and five medical RAG baselines report substantial improvements in answer quality and Evidence F1 with fewer evidence tokens, supported by ablation studies and clinician evaluation. \n\n**Strengths:** \nReviewers 1JmM, q6S3, and RrbL agree that the paper addresses an important and clearly motivated problem in high stakes medical question answering through a novel shift from passage ranking to compact evidence subset optimization. They also recognize the clear presentation, comprehensive technical pipeline, strong empirical results across multiple models and datasets, detailed ablations, and inclusion of clinician based evaluation. \n\n**Weaknesses:** \nReviewers 1JmM, q6S3, and RrbL question whether the hidden state information gain signals generalize across different frozen models, architectures, middle layer choices, and judge models. Reviewers 1JmM and q6S3 highlight that the considerable inference latency and hardware requirements weaken the claimed efficiency benefits and leave practical clinical integration insufficiently addressed. Reviewer q6S3 notes that the cross layer coherence and gradient signals appear heuristic, provide relatively limited gains, and lack sufficient theoretical or architecture independent validation. Reviewers q6S3 and RrbL request stronger analysis of the selection mechanism, including comparisons with greedy selection using identical IGS scores, sensitivity under tighter token budgets, clearer Evidence F1 definitions, and more informative qualitative success and failure cases. \n\n**Response Direction:** \nA convincing response should demonstrate robustness across scorer and judge families, provide latency and deployment analyses, justify each IGS component, and add controlled greedy, budget sensitivity, metric clarification, and qualitative failure case evaluations.\n\n---\n\nThe authors substantially addressed the flagged technical concerns through new robustness tests, budget-matched and greedy-selector comparisons, latency and deployment clarifications, and failure-case analysis; in discussion, RrbL found the clarifications satisfactory, q6S3 raised the rating from 3 to 4 while retaining concerns about the paper’s framing, and 1JmM provided no further feedback.\n\nI recommend a borderline accept because the paper presents a well-motivated and technically solid approach to compact evidence subset selection, supported by strong multi-model, multi-dataset, ablation, and clinician evaluations, while the remaining concerns about the “less evidence” framing, inference latency, and clinical deployment temper rather than outweigh its contributions.",
+ "final_justification": "Taking the reviews, author response, and discussion together, I recommend borderline accept, as the additional evidence resolves most technical concerns and leaves the reasons for acceptance narrowly stronger than the remaining limitations."
+ },
+ "createdAt": "2026-09-24T11:20:28.313Z",
+ "modifiedAt": "2026-11-18T14:54:54.328Z",
+ "url": "https://openreview.net/forum?id=PsPjtMRFBs&noteId=STmwstmgpm",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/pspjtmrfbs/notes/wcgsqpge8e.json added

+++ b/reviews/openreview/pspjtmrfbs/notes/wcgsqpge8e.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "WcGsQPgE8E",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer q6S3",
+ "content": {
+ "summary": "This paper addresses the limitations of RAG in medical question answering (QA), where traditional top-k retrieval often yields redundant, partially relevant, or non-critical context. To overcome this, the authors introduce MEGA, a framework that reformulates evidence retrieval as a budgeted minimal sufficient evidence selection problem.\n\nThe MEGA framework operates through three primary components:\n1.Subquery Generation and Hybrid Retrieval: Decomposing complex clinical queries to build a comprehensive, recall-oriented candidate evidence pool.\n2.Information Gain Scoring (IGS): Utilizing the internal hidden states of a frozen Large Language Model (LLM) to measure whether a candidate snippet contributes novel, decision-critical information, rather than merely sharing surface-level relevance with the query.\n3.FPTAS Evidence Selector: Framing the final subset selection as an NP-hard 0/1 knapsack optimization problem and employing a Fully Polynomial-Time Approximation Scheme (FPTAS) to select a compact, high-utility evidence subset under a strict token budget.\n\nAs a other contribution to the field, the authors also construct two new evidence-grounded benchmarks: a clinician-curated colorectal cancer dataset (CRC-EvidenceQA) and an open-data biomedical dataset (Med-EvidenceQA). Through extensive experiments, the paper demonstrates that MEGA consistently outperforms existing medical RAG baselines across different LLM backbones. It achieves significant improvements in both final answer quality and evidence grounding (measured by Evidence F1) while substantially reducing the total number of evidence tokens passed to the generator.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "### 1. Quality\n\nThe overall technical design of the paper is comprehensive but exhibits the following shortcomings in methodological rigor, experimental objectivity, and engineering practicality, which require the author's focused response:\n\na.The IGS algorithm heavily relies on the magnitude of shifts in hidden layer states (e.g., representation drift and cosine shifts). However, in medical contexts, retrieving \"wrong conclusions\" that strongly contradict the current context (e.g., mistaking contraindications for indications) can similarly induce significant internal state oscillations. The framework currently lacks a mechanism to distinguish between \"high-value correct gains\" and \"high-noise disruptive errors,\" revealing a flawed assumption.\nb. The main text highlights that MEGA reduces tokens by 35.6% to improve \"efficiency.\" However, Appendix E.3.2 reveals that when computing IGS with Qwen3-8B, each query takes an average of 32.0 seconds. The paper should discuss the tradeoff between token reduction and time inefficiency.\nc. The concepts of Cross-Layer Coherence and Cross-Layer Gradients are not adequately supported by theory or experimentation. The authors should clarify whether these are purely heuristic designs. More importantly, ablation studies reveal that their actual performance contribution is negligible while introducing substantial computational overhead. This raises questions about their practical value. Furthermore, the robustness of these signals remains unproven in architectures beyond Qwen.\nd. While Equation (1) introduces a penalty term, to dynamically regulate evidence length and approximate a minimum sufficient set, the FPTAS algorithm still depends on a \"hard threshold upper limit B\" manually fine-tuned on the validation set. This dual constraint appears redundant, leaving ambiguity about which component plays the primary role.\n\n\n### 2. Clarity\n\nThe overall structure of the paper is clear and well-written, but there are ambiguities in detailing critical evaluation metrics and visual presentation of results:\n\na. The explanation and comparison of Evidence F1 are insufficiently clear in the main body. For example, MEGA’s ev-F1 and the ev-F1 of Context+LLM differ in their calculation, yet they are presented in the same table without explicit clarification, which can mislead readers. Many critical evaluation details are relegated to the appendix.\nb. In Figure 3, the numerical labels and error bars are heavily overlapping, while in Figure 4, data points are also cluttered. Both issues undermine the intuitive communication of insights from the data.\n\n### 3. Significance\n\nThe clinical motivation of the paper is compelling. In medical evidence-based Q&A contexts, evidence accuracy and traceability (traceability to reliable sources) are equally critical.\n\n### 4. Originality\n\nThe study presents innovative methodology, breaking away from the conventional reliance on traditional cross-encoder calculations of external relevance in medical RAG tasks. It proposes a novel approach that leverages frozen LLM intermediate layer hidden states to quantify information gain and combines this with an FPTAS algorithm to solve a knapsack problem. However, as mentioned under the \"Quality\" dimension, the use of intermediate-layer features currently leans heavily towards \"heuristic engineering design\" and lacks a solid theoretical framework.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 3,
+ "questions": "a.The IGS algorithm heavily relies on the magnitude of shifts in hidden layer states (e.g., representation drift and cosine shifts). However, in medical contexts, retrieving \"wrong conclusions\" that strongly contradict the current context (e.g., mistaking contraindications for indications) can similarly induce significant internal state oscillations. The framework currently lacks a mechanism to distinguish between \"high-value correct gains\" and \"high-noise disruptive errors,\" revealing a flawed assumption.\nb. The main text highlights that MEGA reduces tokens by 35.6% to improve \"efficiency.\" However, Appendix E.3.2 reveals that when computing IGS with Qwen3-8B, each query takes an average of 32.0 seconds. The paper should discuss the tradeoff between token reduction and time inefficiency.\nc. The concepts of Cross-Layer Coherence and Cross-Layer Gradients are not adequately supported by theory or experimentation. The authors should clarify whether these are purely heuristic designs. More importantly, ablation studies reveal that their actual performance contribution is negligible while introducing substantial computational overhead. This raises questions about their practical value. Furthermore, the robustness of these signals remains unproven in architectures beyond Qwen.\nd. While Equation (1) introduces a penalty term, to dynamically regulate evidence length and approximate a minimum sufficient set, the FPTAS algorithm still depends on a \"hard threshold upper limit B\" manually fine-tuned on the validation set. This dual constraint appears redundant, leaving ambiguity about which component plays the primary role.\ne. The explanation and comparison of Evidence F1 are insufficiently clear in the main body. For example, MEGA’s ev-F1 and the ev-F1 of Context+LLM differ in their calculation, yet they are presented in the same table without explicit clarification, which can mislead readers. Many critical evaluation details are relegated to the appendix.\nf. In Figure 3, the numerical labels and error bars are heavily overlapping, while in Figure 4, data points are also cluttered. Both issues undermine the intuitive communication of insights from the data.",
+ "limitations": "The main text highlights that MEGA reduces tokens by 35.6% to improve \"efficiency.\" However, Appendix E.3.2 reveals that when computing IGS with Qwen3-8B, each query takes an average of 32.0 seconds. The paper should discuss the tradeoff between token reduction and time inefficiency.",
+ "rating": 4,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "None",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "I have carefully read the authors’ response, and overall, it has addressed some of my concerns. This is a thoughtfully written and professionally presented paper, and the proposed approach appears to be effective. However, I find the title and the paper’s overall narrative substantially misleading.\n\nFor example, the ablation results suggest that the improvement in QA performance is primarily attributable to the sub-question expansion and hybrid retrieval module, which increases the diversity of the retrieved evidence, rather than to using less evidence. The paper does employ evaluation and selection mechanisms to reduce ineffective evidence tokens as much as possible, but this is not equivalent to claiming that “less evidence leads to better answers.”\n\nFor RAG-based QA systems, the objective at the evidence level has always been to retrieve a complementary, diverse, and effective set of evidence that adequately supports the answer, while minimizing irrelevant, ineffective, and redundant evidence. This objective has not changed, and it does not imply that less evidence is inherently better.\n\nA catchy title may help attract attention and increase the paper’s visibility, but an inaccurate claim can also propagate misconceptions and mislead other researchers, particularly in today’s increasingly attention-driven academic environment.\n\nOverall, I believe the most appropriate rating would be 3.5. Since this option is not available, I have temporarily raised my initial rating to 4. I leave the final assessment to the AC and SAC for their comprehensive consideration."
+ },
+ "createdAt": "2026-06-24T17:47:15.582Z",
+ "modifiedAt": "2026-11-18T13:39:13.754Z",
+ "url": "https://openreview.net/forum?id=PsPjtMRFBs&noteId=WcGsQPgE8E",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/pspjtmrfbs/notes/ykuwmbn9yf.json added

+++ b/reviews/openreview/pspjtmrfbs/notes/ykuwmbn9yf.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "YkuWMbn9yF",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer 1JmM",
+ "content": {
+ "summary": "This manuscript proposes a medical evidence-grounded question-answering method that chooses a small subset of evidence, called MEGA. Main contributions are: 1) It constructs a recall-oriented candidate evidence pool; 2) It uses a frozen LLM to evaluate the information gain; 3) It formulates the evidence selection task as a budgeted utility maximization problem and proposes an FPTAS selector to determine the compact evidence subset. Besides, to evaluate the answer quality and evidence grounding, the manuscript also proposes two QA benchmarks (CRC-EvidenceQA and Med-EvidenceQA).",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "For Quality, this manuscript is complete and well-structured, including a detailed description of the method and ablation studies as well as human studies. But the proposed framework heavily relies on LLMs at multiple stages (e.g., in retrieval, scoring, and LLM-as-a-judge evaluation), which may cause model-dependent bias, and the computational latency is non-negligible (32s per query for Qwen3-8B and 118.4s per query for Qwen3-32B). \n\nFor Clarity, this manuscript is generally clear. The four-stage pipeline is well described, and the appendix is detailed. However, it lacks some qualitative results to show when the method outperforms others and when it fails. \n\nFor Significance, this manuscript studies an important question in question-answering in high-stakes situations such as the medical domain. But considering it costs nontrivial computational resources (4xA100 GPUs, and slow inference time), how to combine it with a real clinical workflow remains less discussed. Moreover, the bias caused by LLMs is also not well addressed, which means the performance may be dependent on the selection of LLMs. \n\nFor Originality, the formulation of the problem is novel and interesting, and constructing a small but compact, sufficient subset as evidence is intuitive. However, there are also other works studying using a small and informative subset to make a prediction, such as Information Bottleneck [1] and Information Pursuit [2]. The discussion and comparison with existing information gain-based methods are expected. \n\n[1] Tishby N, Pereira F C, Bialek W. The information bottleneck method[J]. arXiv preprint physics/0004057, 2000.\n\n[2] Chattopadhyay, et al. Interpretable by design: Learning predictors by composing interpretable queries[J]. IEEE Transactions on Pattern Analysis and Machine Intelligence, 2022, 45(6): 7430-7443.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 3,
+ "questions": "My main questions are as follows:\n\n1.\tCan the authors provide qualitative success and failure cases for the proposed method MEGA? And discussions about why? And also the influence of each component? \n2.\tCan the authors show how robust the information gain score is to the choice of the frozen LLM and judge model? \n3.\tHow can MEGA be integrated into practical scenarios, given the high latency? \n4.\tCan the authors discuss and compare with existing information-gain-based methods [1,2]?\n\n[1] Tishby N, Pereira F C, Bialek W. The information bottleneck method[J]. arXiv preprint physics/0004057, 2000.\n\n[2] Chattopadhyay, et al. Interpretable by design: Learning predictors by composing interpretable queries[J]. IEEE Transactions on Pattern Analysis and Machine Intelligence, 2022, 45(6): 7430-7443.",
+ "limitations": "No. The author acknowledged several limitations, such as limited domain coverage, bilingual but not fully multilingual, text-only setting, and the LLM-as-a-judge bias. However, several important limitations are still insufficiently addressed, for example: \n\n1. The manuscript should provide more explicit discussion of failure modes, especially including qualitative results. In a high-stakes medical QA system, it's important to understand when the MEGA selects insufficient, redundant, or misleading evidence. \n\n2. The manuscript should discuss the heavy dependence on LLMs throughout the pipeline, such as for query decomposition, hidden-state scoring, answer generation, and evaluation. Although the manuscript provides sensitivity analysis for the frozen scorer, the robustness of the score to different LLM families and different judge models remains underexplored. \n\n3. The nontrivial computational cost and latency also need discussion as a practical limitation.\n\n4. The manuscript should also discuss its relationship to other information-gain-based methods, such as Information Bottleneck and Information Pursuit. This will help clarify the novelty of the proposed method.",
+ "rating": 3,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only",
+ "CLEAR MAJOR CONCERN: Check this box if there is a clear, major concern for which you do not need further clarifications. Detail the concern in the Strengths and Weaknesses section. Use another option below if you would benefit from a consultation with an expert."
+ ],
+ "paper_formatting_concerns": "I didn't notice major issues with paper formatting.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes"
+ },
+ "createdAt": "2026-06-26T09:07:28.429Z",
+ "modifiedAt": "2026-11-18T13:39:12.131Z",
+ "url": "https://openreview.net/forum?id=PsPjtMRFBs&noteId=YkuWMbn9yF",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/pspjtmrfbs/notes/zaqwforhgr.json added

+++ b/reviews/openreview/pspjtmrfbs/notes/zaqwforhgr.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "ZAqwfORhGR",
+ "replyTo": "ShZ9p1Yit3",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "We sincerely thank Reviewer RrbL for the time and care devoted to evaluating our work. We greatly appreciate your encouraging assessment of the paper’s quality and clarity, and your recognition that it addresses a well-defined problem rigorously. We provide additional experiments and clarifications below.\n\n---\n\n#### ***Q1: How sensitive is the performance to the choice of the 'middle layers' or the specific frozen model used, and does the information gain signal generalize across different model architectures or is it tightly coupled to the scoring model's internal representations?***\n\n**A1:** We conducted two additional experiments on (1) sensitivity to the middle-layer range and (2) robustness across frozen scorers from different families and scales.\n\nFollowing Appendix E.3.1, we use 100 CRC-EvidenceQA and 200 Med-EvidenceQA examples (100 PubMedQA and 100 COVID-QA). GPT-5.1 is the judge, and all other settings remain fixed.\n\n**Sensitivity to the choice of the middle layers.** We partition normalized model depth into four equal-width regions and additionally test the default middle half, $[L/4,3L/4]$. For the quarter-depth settings, we uniformly sample the same number of layers. Only the IGS layer set changes; the scorer, answer backbone, retrieval results, selector hyperparameters, prompts, and random seeds remain fixed.\n\n> **Table 1. Sensitivity to the hidden-layer region used by IGS.**\n\n| Scoring region | KP-AUROC $\\uparrow$ | KP-Spearman $\\rho\\uparrow$ | Ans. Quality $\\uparrow$ | Evi. F1 (%) $\\uparrow$ |\n| ---------------------------------------- | ------------------: | -------------------------: | ----------------------: | ---------------------: |\n| Early $[0,\\frac14]$ | 0.54 | 0.35 | 7.96 | 68.9 |\n| Lower-middle $[\\frac14,\\frac12]$ | 0.68 | 0.55 | 8.39 | 78.6 |\n| Upper-middle $[\\frac12,\\frac34]$ | 0.72 | 0.59 | 8.53 | 81.2 |\n| Late $[\\frac34,1]$ | 0.57 | 0.38 | 8.08 | 70.7 |\n| Middle-half $[\\frac14,\\frac34]$, default | **0.77** | **0.66** | **8.74** | **84.6** |\n\nThe middle regions clearly outperform the early and late regions, and the default middle-half setting performs best on all metrics. Compared with the strongest individual region, it improves KP-AUROC by 0.05, Spearman correlation by 0.07, answer quality by 0.21, and Evidence F1 by 3.4 points. Early layers mainly encode lexical and local contextual features, while late layers are more oriented toward next-token prediction and response realization. Middle layers better capture query–evidence integration. Aggregating the broader middle half also allows cross-layer coherence and information-gradient signals to model a more stable evidence-integration trajectory. These results support $[L/4,3L/4]$ as a principled default.\n\n> **Table 2. Robustness to the frozen scorer model.**\n\n| Frozen scorer | Params | kp-AUROC | kp-Spearman | Ans. Quality | Evi. F1 | Time |\n| --------------------- | -----: | ----: | -------: | -----------: | ------: | ----------: |\n| Qwen3-8B | 8B | 0.77 | 0.66 | 8.74 | 84.6 | 1.0$\\times$ |\n| Qwen3-4B | 4B | 0.57 | 0.54 | 6.38 | 66.4 | 0.7$\\times$ |\n| Qwen3-32B | 32B | 0.79 | 0.68 | 8.80 | 85.1 | 3.7$\\times$ |\n| Llama-3.1-8B-Instruct | 8B | 0.75 | 0.66 | 8.69 | 83.9 | 1.1$\\times$ |\n| Mistral-7B-v0.1 | 7B | 0.74 | 0.63 | 8.52 | 83.2 | 0.9$\\times$ |\n\nThe signal transfers consistently across Qwen, Llama, and Mistral. The two non-Qwen scorers remain within 1.6 Evidence-F1 points and 0.22 answer-quality points of Qwen3-8B. Increasing Qwen from 8B to 32B yields only +0.5 Evidence F1 and +0.06 answer quality, but costs 3.7$\\times$ more runtime. The 4B scorer is substantially weaker, indicating that very small scorers produce noisier utility estimates. Overall, IGS is not tightly coupled to a particular architecture, although smaller models may require calibration.\n\n---\n\n#### ***Q2: The token budget B is tuned on a development split. Since B is a critical hyperparameter for the compactness claim, how does the performance vary across different budget constraints? Specifically, is there a threshold where reducing the budget significantly degrades answer quality, and how does MEGA's Pareto frontier compare to baselines when the budget is extremely tight?***\n\n**A2:** We sweep $B$ using the same 300 examples as Q1, while fixing the candidate pool, IGS scorer, answer model, and all other hyperparameters.\n\n> **Table 3. Sensitivity to the evidence-token budget $B$.**\n\n| Budget $B$ | Avg. selected tokens | Ans. Quality $\\uparrow$ | Evi. F1 (%) $\\uparrow$ |\n| ---------: | -------------------: | ----------------------: | ---------------------: |\n| 256 | 239 | 7.74 | 65.7 |\n| 384 | 361 | 8.17 | 74.6 |\n| 512 | 476 | 8.48 | 80.9 |\n| 768 | 598 | 8.69 | 83.8 |\n| 1024 | 608 | 8.73 | 84.4 |\n| 1536 | 611 | 8.74 | 84.5 |\n\nA clear transition occurs around $B=512$--$768$. Below this range, the budget excludes clinically necessary evidence, sharply reducing evidence recall and answer quality. Beyond $B\\approx1024$, performance saturates. This is because $B$ is an upper bound rather than a target: the selector need not fill the context, and non-positive-utility candidates are discarded before optimization. Thus, larger budgets do not force noisy evidence into the selected set.\n\nFor a controlled Pareto comparison, we impose the same hard budget on all methods. Baselines without an explicit budget mechanism retain passages in their original ranking order until the next passage would exceed $B$.\n\n> **Table 4. Budget-matched comparison under extremely tight budgets.**\n\n| Method | Quality @256 $\\uparrow$ | Evi. F1 @256 $\\uparrow$ | Quality @512 $\\uparrow$ | Evi. F1 @512 $\\uparrow$ |\n| ----------------------- | ----------------------: | ----------------------: | ----------------------: | ----------------------: |\n| Reranker-TopBudget | 7.18 | 52.8 | 7.84 | 64.6 |\n| DoctorRAG-TopBudget | 7.36 | 57.4 | 8.01 | 68.9 |\n| Greedy$_{\\mathrm{IGS}}$ | 7.55 | 62.8 | 8.31 | 77.4 |\n| MEGA | **7.74** | **65.7** | **8.48** | **80.9** |\n\nMEGA maintains the strongest quality–budget trade-off under both tight settings. The advantage is largest at $B=256$, where an independently ranked long or redundant snippet can consume most of the available budget.\n\n---\n\n#### ***Q3: The paper compares MEGA against several RAG baselines, but does not explicitly compare the FPTAS selector against a simple greedy selection based on the same IGS scores. Could the authors provide a comparison between Greedy(IGS) and FPTAS(IGS) to clarify if the optimization complexity is providing the observed gains over a simpler heuristic?***\n\n**A3:** We add two greedy variants with the same candidate pool and IGS utilities. Greedy-Value sorts by $v_i$, while Greedy-Density sorts by $v_i/t_i$. All other components remain fixed. The surrogate gap is measured against the exact 0/1-knapsack optimum.\n\n> **Table 5. Comparison of selectors using the same IGS utilities.**\n\n| Selector | Surrogate gap $\\downarrow$ | Ans. Quality $\\uparrow$ | Evi. F1 (%) $\\uparrow$ | Tokens $\\downarrow$ | Solver time |\n| --------------------- | -------------------------: | ----------------------: | ---------------------: | ------------------: | ----------: |\n| Greedy-Value | 8.7% | 8.57 | 81.0 | 705 | 0.06 ms |\n| Greedy-Density | 4.2% | 8.65 | 82.6 | 664 | 0.09 ms |\n| FPTAS, $\\epsilon=0.1$ | **0.9%** | **8.74** | **84.6** | **612** | 1.0 ms |\n\nFPTAS improves over the stronger Greedy-Density variant by +2.0 Evidence-F1 points and +0.09 answer quality while selecting fewer tokens. Greedy selection makes irreversible local choices and can be suboptimal when snippets have heterogeneous token costs; one long, high-valued snippet may block several shorter snippets with greater combined utility. It also provides no $(1-\\epsilon)$ guarantee for 0/1 knapsack. In contrast, the value-scaled FPTAS globally considers feasible utility–cost combinations and guarantees at least $(1-\\epsilon)$ of the optimal surrogate utility.\n\nThe end-to-end gains show that more accurately optimizing the surrogate improves evidence grounding and answer quality. The additional solver cost is only about 1 ms per query, negligible relative to hidden-state scoring and answer generation.\n\n---\nThanks again for your comments. If you have any additional concerns or suggestions, please feel free to share them, and we sincerely value your feedback."
+ },
+ "createdAt": "2026-07-27T16:45:08.915Z",
+ "modifiedAt": "2026-11-18T17:15:43.251Z",
+ "url": "https://openreview.net/forum?id=PsPjtMRFBs&noteId=ZAqwfORhGR",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/pspjtmrfbs/submission.json added

+++ b/reviews/openreview/pspjtmrfbs/submission.json
@@ -0,0 +1,12 @@
+{
+ "schema": "submission/1",
+ "id": "PsPjtMRFBs",
+ "venue": {
+ "id": "NeurIPS.cc/2026/Conference",
+ "name": "NeurIPS 2026",
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"
+ },
+ "number": 13920,
+ "url": "https://openreview.net/forum?id=PsPjtMRFBs",
+ "license": "CC-BY-4.0"
+}

versions/v_kjk2eb3w.json added

+++ b/versions/v_kjk2eb3w.json
@@ -0,0 +1,22 @@
+{
+ "date": "2026-05-02",
+ "kind": "submitted",
+ "label": "NeurIPS 2026",
+ "submissions": [
+ {
+ "venue": "NeurIPS 2026",
+ "status": "accepted",
+ "decision": "Accept (poster)",
+ "number": 13920,
+ "url": "https://openreview.net/forum?id=PsPjtMRFBs",
+ "reviews": "openreview/pspjtmrfbs",
+ "evidence": [
+ "https://openreview.net/forum?id=PsPjtMRFBs"
+ ]
+ }
+ ],
+ "url": "https://openreview.net/forum?id=PsPjtMRFBs",
+ "evidence": [
+ "https://openreview.net/forum?id=PsPjtMRFBs"
+ ]
+}