potentialpaper

Fast Accurate Quantum Monte Carlo without Metropolis Adjustment

Update NeurIPS 2026 submission 2qZHSkdQpV: 6 notes

@openreview[bot] · 2026-11-24 15:45 UTC · 22f00dc89c37 ·

Evidence

reviews/openreview/2qzhskdqpv/notes/1uu6qwhau2.json added

+++ b/reviews/openreview/2qzhskdqpv/notes/1uu6qwhau2.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "1Uu6qWhaU2",
+ "replyTo": null,
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Area Chair RacJ",
+ "content": {
+ "title": "Discussion period ending soon",
+ "comment": "Hi Reviewers,\n\nThe discussion period ends August 3. Please respond to the authors' rebuttal on whether or not your concern(s) have been addressed.\n\nThanks!\n\nAC"
+ },
+ "createdAt": "2026-08-02T22:06:10.008Z",
+ "modifiedAt": "2026-11-19T17:19:06.439Z",
+ "url": "https://openreview.net/forum?id=2qZHSkdQpV&noteId=1Uu6qWhaU2",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/2qzhskdqpv/notes/8gnt8xcwon.json modified

+++ b/reviews/openreview/2qzhskdqpv/notes/8gnt8xcwon.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair RacJ",
"content": {
- "metareview": "This paper proposes the use of unadjusted gradient-based samplers for quantum Monte Carlo applications, discussing how to tune them such that the bias-variance is appropriately controlled.\n\nThis paper was originally borderline, with all reviewers falling in the borderline accept/reject recommendation. After the author response, all reviewers were in favor of accepting the paper.\n\nSome concerns from reviewers that could improve the manuscript include:\n1) algorithmic novelty relative to prior work and how this could be improved in the paper\n2) tuning and bias diagnostic's positioning relative to prior work\n3) how to improve the general clarity for a NeurIPS audience and citations of related work\n4) more careful discussion of baselines and why they were included and why others were not (several reviewers commented on this)\n5) clarify runtime/compute budgets of the current experiments\n\nThe author response highlighted the novelty of studying unadjusted HMC for this application. I think the author response played a role in clarifying this paper's contributions, and I think it is appropriate as a \"use inspired\" paper."
+ "metareview": "This paper proposes the use of unadjusted gradient-based samplers for quantum Monte Carlo applications, discussing how to tune them such that the bias-variance is appropriately controlled.\n\nThis paper was originally borderline, with all reviewers falling in the borderline accept/reject recommendation. After the author response, all reviewers were in favor of accepting the paper.\n\nSome concerns from reviewers that could improve the manuscript include:\n1) algorithmic novelty relative to prior work and how this could be improved in the paper\n2) tuning and bias diagnostic's positioning relative to prior work\n3) how to improve the general clarity for a NeurIPS audience and citations of related work\n4) more careful discussion of baselines and why they were included and why others were not (several reviewers commented on this)\n5) clarify runtime/compute budgets of the current experiments\n\nThe author response highlighted the novelty of studying unadjusted HMC for this application. I think the author response played a role in clarifying this paper's contributions, and I think it is appropriate as a \"use inspired\" paper.",
+ "final_justification": "Overall, the author response helped to improve the reviewers' opinion of the paper, and several reviewers increased their scores.\n\nThe paper should be thoroughly revised to address the discussion with the reviewers, from emphasizing the novelty relative to prior work, related work and baselines discussions, and more clearly presenting runtime/compute budgets of the current experiments. Some remaining concerns that reviewers have mentioned include releasing the code and addressing Reviewer xHQA's remaining concern about the $\\epsilon$ vs $\\epsilon/2$ diagnostic."
},
"createdAt": "2026-07-22T14:22:48.059Z",
- "modifiedAt": "2026-11-18T15:21:19.176Z",
+ "modifiedAt": "2026-11-19T05:00:48.204Z",
"url": "https://openreview.net/forum?id=2qZHSkdQpV&noteId=8GNt8xcWON",
"license": "CC-BY-4.0"
}

reviews/openreview/2qzhskdqpv/notes/d27ragckyd.json added

+++ b/reviews/openreview/2qzhskdqpv/notes/d27ragckyd.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "d27rAgckYd",
+ "replyTo": "Z6pRmN1n4g",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Thanks for your reply.\n\nRe the \"order of magnitude\" claim, that's a fair point, we'll reformulate the claim in the paper. The point we'll emphasize in the paper is that the systems of physical relevance are the largest ones (largest $L$ and $N_\\tau$), so the fact that the scaling of the efficiency of the unadjusted samplers with $L$ (and pending further analysis $N_\\tau$) is favorable relative to HMC is really the important contribution of the method. \n\nRegarding the disordered method, the interesting point is that the disorder introduces another source of variance, so relative to the total variance (from both disorder and the finite sample size), the bias is smaller. That is to say, we believe that the unadjusted sampler could be safely used with a larger step size for the disordered system, yielding more favourable results. We will analyze this case in detail if the paper is accepted.\n\nRegarding the code, I think in theory we could provide an anonymized snapshot of at least a subset of the code, but -- at the risk of sounding evasive -- it would be tricky to reach an author consensus, prepare it, and make sure that it is satisfactorily anonymous before the end of the author-reviewer period (which I believe is in a few hours). Sorry, I realize this is frustrating."
+ },
+ "createdAt": "2026-08-04T02:09:38.799Z",
+ "modifiedAt": "2026-11-19T17:19:06.244Z",
+ "url": "https://openreview.net/forum?id=2qZHSkdQpV&noteId=d27rAgckYd",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/2qzhskdqpv/notes/t5oqnfqerl.json added

+++ b/reviews/openreview/2qzhskdqpv/notes/t5oqnfqerl.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "t5OQnfqerl",
+ "replyTo": "TWzoIfk452",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Thanks for your response.\n\nWe agree that the $\\epsilon$ vs $\\epsilon/2$ diagnostic ($b_\\epsilon$) is not guaranteed to control the bias. Our claim, which we will clarify in the paper, is empirical: across $L, N_\\tau, \\lambda$, the true bias is no more than twice \n (we will add a scatter plot showing this). This is in keeping with our finding that the bias $b_a \\sim \\epsilon^p$ with $p > 2$, which we will also include. Re the uncertainty intervals, the point is well taken and we will amend the paper accordingly - however we do note that initialization bias (present also in adjusted HMC) is not typically accounted for in error bars in the literature."
+ },
+ "createdAt": "2026-08-04T02:12:03.824Z",
+ "modifiedAt": "2026-11-19T17:19:06.231Z",
+ "url": "https://openreview.net/forum?id=2qZHSkdQpV&noteId=t5OQnfqerl",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/2qzhskdqpv/notes/twzoifk452.json added

+++ b/reviews/openreview/2qzhskdqpv/notes/twzoifk452.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "TWzoIfk452",
+ "replyTo": "1vw7xE8sPn",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer xHQA",
+ "content": {
+ "comment": "I would like to thank the authors for their detailed rebuttal. They have addressed most of my concerns by clarifying the scope and novelty of their contribution, explaining the comparison with adjusted HMC and the source of the observed efficiency gains, providing the missing citations and methodological clarification, improving the motivation for a machine-learning audience, and providing additional results at $N_\\tau=80$.\n\nHowever, one issue is still only partially resolved. The $\\epsilon$ versus $\\epsilon/2$ diagnostic compares the expectations produced by two discretized samplers, but it does not directly control either sampler’s bias relative to the true target. Two discretizations could agree closely while sharing a similar non-negligible bias. So this diagnostic alone does not fully justify treating discretization bias as negligible, or omitting it from the reported uncertainty intervals, across the considered settings. \n\nStill, the authors have satisfactorily addressed the rest of my concerns so I have therefore raised my score."
+ },
+ "createdAt": "2026-08-03T04:08:35.858Z",
+ "modifiedAt": "2026-11-19T17:19:06.439Z",
+ "url": "https://openreview.net/forum?id=2qZHSkdQpV&noteId=TWzoIfk452",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/2qzhskdqpv/notes/z6prmn1n4g.json added

+++ b/reviews/openreview/2qzhskdqpv/notes/z6prmn1n4g.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "Z6pRmN1n4g",
+ "replyTo": "ccJSJTIkER",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer Cnrs",
+ "content": {
+ "comment": "Thanks for the response and the extra runs.\n\nQ1 is addressed. Confirming everything is counted in gradient evaluations rather than integrator steps was the main thing I needed. Q3 is mostly settled. Please include the table with the error bars and ESS_n as you offered, and state in the paper that the reported ESS is warm start and excludes tuning and burn-in, so it is not read as an end-to-end speedup.\n\nThe disordered system and N_tau=80 answer my fourth weakness, on generalization. One observation from those tables. The advantage over aHMC is about 2.2x to 4x on the disordered system and around 4x at N_tau=80, both at L=64, against about 6x for the clean system at the same L and 10x to 16x at L=128. So \"around an order of magnitude\" in the abstract is the best case rather than the typical one. Could you state the observed range and where the large factors come from instead of one headline number?\n\nThe baseline justification is fine, I do not have a better one in mind.\n\nThat leaves code. My question 2 asked for release of the sampler, compiler and tuning code without the large datasets, or an anonymized snapshot during the rebuttal. The response covers the first option and says release is not possible right now, but does not address the second. Is an anonymized snapshot available?"
+ },
+ "createdAt": "2026-08-04T01:41:04.564Z",
+ "modifiedAt": "2026-11-19T17:19:06.254Z",
+ "url": "https://openreview.net/forum?id=2qZHSkdQpV&noteId=Z6pRmN1n4g",
+ "license": "CC-BY-4.0"
+}