Equivariant Force Field Calibration for Flow-based Protein Design
Update NeurIPS 2026 submission FVSOcen7JO: 10 notes
@openreview[bot] · 2026-11-24 15:48 UTC · 20930f30cdcf ·
reviews/openreview/fvsocen7jo/notes/epbcxo2jv5.json added
+++ b/reviews/openreview/fvsocen7jo/notes/epbcxo2jv5.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "EpBcxo2jV5",+ "replyTo": "TpSw3gd5Ct",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer Wrss",+ "comment": "We thank the reviewer for the positive assessment and for recognizing why force-field supervision is most meaningful near a physical terminal state.\n\n## 1. Inaccessible $u^\\star$ and $q_t^\\star$\n\n> The theoretical argument is largely intuitive because $u^\\star$ and $q_t^\\star$ are inaccessible.\n\nWe agree. The theory is not a practical convergence guarantee. It provides an idealized interpretation conditional on a fixed reference field and path measure. The revision will explicitly state that:\n\n1. a terminal distribution does not identify a unique transport;\n2. the practical algorithm replaces $u^\\star$ with a force-corrected teacher target;\n3. terminal calibration plus consistency is a surrogate, not an exact solution of the ideal objective.\n\n## 2. Comparison with RL or GFlowNet methods such as AbFlowNet\n\n> How does FFC compare with RL or GFlowNet optimization of an energy function?\n\nThe methods differ in their optimization object and assumptions:\n\n| Approach | Optimized object | Reward use | Evaluator at inference | Main requirement |\n|---|---|---|---|---|\n| RL fine-tuning | policy over sampled trajectories | training | no | stochastic policy-gradient optimization |\n| GFlowNet | reward-proportional terminal sampling | training | no | task-specific sequential construction graph |\n| Inference-time force guidance | molecular state at each step | inference | yes | differentiable force calls during sampling |\n| FFC | parameters of a pretrained flow/student | post-training | no | differentiable terminal guidance during calibration |\n\nA direct numerical comparison with published AbFlowNet results would be confounded by the design task, action space, architecture, dataset, and reward. We will discuss AbFlowNet and related work as complementary approaches, but we will not present unmatched cross-paper numbers as a controlled comparison.\n\nThe controlled evidence currently available is the matched PepFlow comparison above. FFC outperforms energy conditioning, inference-time force guidance, idempotent guidance, and consistency-only training while retaining the base model’s 0.05 s/sample inference cost.\n\n## 3. Why diversity decreases\n\n> There is a fairly consistent decline in diversity.\n\nWe agree that the manuscript should distinguish three effects:\n\n1. **Denominator effect:** normalized diversity divides cluster count by the number of designable samples, and FFC increases designability.\n2. **Physical concentration:** force calibration can concentrate samples in lower-energy regions.\n3. **Few-step compression:** consistency training may reduce variation at very small sampling budgets.\n\nThe absolute cluster counts provide a more nuanced picture:\n\n- 10 steps: 124 $\\rightarrow$ 121;\n- 100 steps: 147 $\\rightarrow$ 135;\n- 500 steps: 123 $\\rightarrow$ 126.\n\nWe will revise the claim to acknowledge a modest quality–diversity trade-off and include the absolute counts beside the normalized metric. The appendix sensitivity study already supports this interpretation: moderate force weights improve quality, whereas excessive force strength causes marked deterioration and changes the quality–novelty balance.\n\n## 4. Eq. (1): energy versus force field\n\n> Eq. (1) suggests that an explicit differentiable energy is required, while later equations use a force field.\n\nWe agree. Eq. (1) is a motivating special case for a conservative field. The implemented regression only requires a vector-valued terminal guidance field. When $F=-\\nabla E$, Eq. (1) admits an energy-reweighting interpretation. For a non-conservative learned guidance field, calibration remains possible, but the Gibbs-reweighting interpretation no longer applies.\n\n## 5. Use of the relaxed terminal structure\n\n> It is unclear where $\\widetilde x_1$ is used.\n\nWe will use consistent Cartesian notation:\n\n$ \\widehat y_1=\\zeta(\\widehat z_1), \\qquad \\widetilde y_1 = \\mathrm{sg}[ \\mathrm{Relax}(\\widehat y_1) ], $\n\n$ \\widetilde F_1 = \\mathrm{NormalizeClip} [ F(\\widetilde y_1) ],$\n\n$y_{\\mathrm{target}} = \\mathrm{sg} [ y_{\\mathrm{teacher}} + \\lambda_F\\widetilde F_1 ]. $\n\nRelaxation is used only to obtain a numerically stable force target; no gradient is propagated through minimization.\n\n## 6. Should Eq. (2) account for relaxation?\n\nYes. The practical target uses $F(\\widetilde y_1)$, not $F(\\widehat y_1)$. We will correct Eq. (2) and the surrounding notation.\n\n## 7. Limitations\n\nWe will add a visible limitations section covering:\n\n- dependence on the fidelity of the force field or learned guidance;\n- force-evaluation cost during calibration;\n- sensitivity to $\\lambda_F$;\n- the quality–diversity trade-off;\n- the fact that classical force fields do not guarantee biological function or experimental binding;\n- the absence of wet-lab validation."+ },+ "createdAt": "2026-07-28T19:38:57.772Z",+ "modifiedAt": "2026-11-19T17:10:38.912Z",+ "url": "https://openreview.net/forum?id=FVSOcen7JO¬eId=EpBcxo2jV5",+ "license": "CC-BY-4.0"+}
reviews/openreview/fvsocen7jo/notes/iw5oefhwhy.json modified
+++ b/reviews/openreview/fvsocen7jo/notes/iw5oefhwhy.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair idLL","content": {- "metareview": "This paper presents FFC, a method that calibrates a pretrained flow model toward physically valid conformations by aligning its terminal velocity to a differentiable force-field gradient, coupled with a consistency-based training strategy for few-step sampling; it is evaluated on unconditional protein, peptide, and antibody design. Reviewers agree the central idea is interesting, applying the force field at the terminal state neatly sidesteps the problem of scoring non-physical intermediate objects. The disagreement is about theoretical rigor and evaluation completeness. I recommend the authors to address the following problems: \n\n1. Absence of baselines (especially other force field guidance methods). Two reviewers flagged that experiments compare only FFC vs. no-FFC on each base model. However, the introduction of this paper mentioned a lot of related force field guidance / calibration methods. Even though the results in the paper looks good, it is unclear whether the proposed FFC method is better than prior related work. Also, the unconditional protein backbone generation doesn't have any baseline (unless I missed it). Besides absolute performance, the authors should also report sampling efficiency of FFC and compare with previous energy guidance methods.\n\n2. There seem to be some problems in the derivation of FFCs (as flagged by two reviewers). Also, it's unclear whether the consistency flow is learned first and then calibrated (\"once the consistency-regularized flow is learned…\") or jointly optimized, and a reviewer raises a specific failure mode: the consistency loss merely tracking the teacher while calibration independently adjusts the endpoint."+ "metareview": "This paper presents FFC, a method that calibrates a pretrained flow model toward physically valid conformations by aligning its terminal velocity to a differentiable force-field gradient, coupled with a consistency-based training strategy for few-step sampling; it is evaluated on unconditional protein, peptide, and antibody design. Reviewers agree the central idea is interesting, applying the force field at the terminal state neatly sidesteps the problem of scoring non-physical intermediate objects. The disagreement is about theoretical rigor and evaluation completeness. I recommend the authors to address the following problems: \n\n1. Absence of baselines (especially other force field guidance methods). Two reviewers flagged that experiments compare only FFC vs. no-FFC on each base model. However, the introduction of this paper mentioned a lot of related force field guidance / calibration methods. Even though the results in the paper looks good, it is unclear whether the proposed FFC method is better than prior related work. Also, the unconditional protein backbone generation doesn't have any baseline (unless I missed it). Besides absolute performance, the authors should also report sampling efficiency of FFC and compare with previous energy guidance methods.\n\n2. There seem to be some problems in the derivation of FFCs (as flagged by two reviewers). Also, it's unclear whether the consistency flow is learned first and then calibrated (\"once the consistency-regularized flow is learned…\") or jointly optimized, and a reviewer raises a specific failure mode: the consistency loss merely tracking the teacher while calibration independently adjusts the endpoint.",+ "final_justification": "All reviewers have read authors response. Two reviewers remain very positive of the paper, while one reviewer had opposite view. AC has gone through the author response and found that authors have provided sufficient comparison with other guidance methods during rebuttal and additional baseline. While some minor issues remain, the main concern have been addressed. Therefore, AC recommends acceptance."},"createdAt": "2026-07-26T10:16:03.548Z",- "modifiedAt": "2026-11-18T15:21:28.896Z",+ "modifiedAt": "2026-11-19T05:00:52.681Z","url": "https://openreview.net/forum?id=FVSOcen7JO¬eId=iW5OefhwhY","license": "CC-BY-4.0"}
reviews/openreview/fvsocen7jo/notes/oyzki4o2fc.json added
+++ b/reviews/openreview/fvsocen7jo/notes/oyzki4o2fc.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "OYZkI4o2Fc",+ "replyTo": "t04jF81IdT",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer 5iau (Sec III)",+ "comment": "## 11. Undefined $\\mathcal L_{\\mathrm{prog}}$\n\n> $\\mathcal L_{\\mathrm{prog}}$ in Appendix Table 6 is undefined.\n\nThank you for catching this. $\\mathcal L_{\\mathrm{prog}}$ denotes the **progressive consistency-only baseline** evaluated in the first row of Table 6. We will define it immediately before the table and use one name consistently.\n\nFor completeness, Table 6 reports:\n\n| Loss setting | Val. AAR ↑ | Val. Rot. ↓ | Val. Trans. ↓ |\n|---|---:|---:|---:|\n| Progressive only | 0.030 | 2.486 | 44.78 |\n| $\\mathcal L_{\\mathrm{init}}$ | 0.437 | 1.731 | 4.52 |\n| $\\mathcal L_{t\\text{-time}}+\\mathcal L_{r\\text{-time}}$ | 0.133 | 1.880 | 4.56 |\n| $\\mathcal L_{\\mathrm{init}}+\\mathcal L_{r\\text{-time}}$ | 0.439 | 1.596 | 4.50 |\n| $\\mathcal L_{\\mathrm{init}}+\\mathcal L_{t\\text{-time}}$ | 0.430 | 1.627 | 4.58 |\n| $\\mathcal L_{\\mathrm{init}}+\\mathcal L_{t\\text{-time}}+\\mathcal L_{r\\text{-time}}$ | **0.448** | **1.515** | **4.27** |\n\n## 12. Protein-design clusters and diversity\n\n> Why is the number of clusters worse with FFC, and how are the clusters determined?\n\nTable 1 reports both normalized diversity and the absolute number of structural clusters:\n\n| Steps | Base designability | FFC designability | Base diversity (clusters) | FFC diversity (clusters) |\n|---:|---:|---:|---:|---:|\n| 10 | 0.67 | 0.80 | 0.54 (124) | 0.43 (121) |\n| 100 | 0.77 | 0.83 | 0.28 (147) | 0.26 (135) |\n| 500 | 0.81 | 0.85 | 0.22 (123) | 0.21 (126) |\n\nAt 10 steps, the absolute cluster count changes only from **124 to 121** ($-2.4\\%$), while designability rises from **0.67 to 0.80** ($+19.4\\%$ relative). Therefore, much of the normalized-diversity reduction from 0.54 to 0.43 is a denominator effect: FFC makes more samples designable, and many additional designable samples fall into already occupied structural clusters.\n\nAt 500 steps, the absolute cluster count actually increases from **123 to 126**, even though the normalized ratio changes from 0.22 to 0.21. At 100 steps, the absolute count decreases from 147 to 135, so a real concentration effect remains and should not be dismissed.\n\nWe will add the exact MaxCluster similarity metric, cutoff, and linkage setting used by the evaluation script, and we will revise the interpretation from “diversity is largely preserved” to the more precise claim:\n\n> FFC improves designability and novelty while inducing a modest quality–diversity trade-off; the decline is larger in normalized diversity than in absolute mode count.\n\nWe agree that an MDS visualization and matched-size cluster analysis would be useful supplementary diagnostics. We will include them only if completed and will not rely on unreported results in the rebuttal.\n\n## 13. Antibody setting\n\n> Are the experiments on conventional antibodies or nanobodies?\n\nThe task is **conditional CDR-H3 sequence–structure redesign**, not simultaneous generation of all six CDRs or all three nanobody CDRs. The antigen, framework, and non-designed CDRs are provided as context; only CDR-H3 is masked and generated. We will state this explicitly in the setup to remove the ambiguity.\n\n## 14. Definitions of AAR and RMSD\n\n> AAR measures identity rather than homology; please add a BLOSUM-based statistic and define RMSD precisely.\n\nWe agree. AAR is exact amino-acid recovery:\n\n$ \\mathrm{AAR} = \\frac1L\\sum_{i=1}^{L} \\mathbf 1[ \\widehat a_i=a_i^{\\mathrm{native}} ]. $\n\nIt is an identity statistic, not a homology statistic. The existing antibody result is:\n\n| Method | AAR ↑ | RMSD ↓ |\n|---|---:|---:|\n| UniMoMo-all | 52.34 | 1.04 Å |\n| UniMoMo-all + FFC | **54.03** | **0.99 Å** |\n\nThus, FFC improves exact recovery by **1.69 percentage points** and lowers RMSD by **0.05 Å** (4.8%).\n\nWe will add a BLOSUM-based similarity metric and a mutation matrix in the revision. We will not invent those values before the analysis is complete.\n\nThe RMSD definition will be stated directly from the evaluation script, including:\n\n- the atoms used for alignment;\n- the atoms included in the reported CDR-H3 RMSD;\n- whether carbonyl oxygen is included;\n- treatment of differing residue identities.\n\n## 15. Mutations observed\n\n> Please report the mutations observed.\n\nWe agree. We will add the native-to-generated substitution matrix and summarize exact recovery, conservative substitutions, and non-conservative substitutions. Because these values are not present in the submitted manuscript, we will report them only after rerunning the evaluation, rather than filling them speculatively.\n\n---- \nWe thank the reviewer again for the detailed feedback and constructive suggestions, which definitely help us improve the quality of our manuscript during the rebuttal period. Importantly, these corrections affect the exposition, notation, and theoretical scope, but not the implemented training algorithm or the reported experimental results."+ },+ "createdAt": "2026-07-28T19:51:16.464Z",+ "modifiedAt": "2026-11-19T17:10:38.868Z",+ "url": "https://openreview.net/forum?id=FVSOcen7JO¬eId=OYZkI4o2Fc",+ "license": "CC-BY-4.0"+}
reviews/openreview/fvsocen7jo/notes/pguqqxqbmy.json added
+++ b/reviews/openreview/fvsocen7jo/notes/pguqqxqbmy.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "PgUqQXQbMY",+ "replyTo": "Q0z6m0Rj7m",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Follow-up on the Remaining Concerns",+ "comment": "Dear Reviewer,\n\nWe would like to kindly follow up as the discussion period is approaching its end.\n\nIn our previous response, we clarified the distinction between raw and normalized forces, agreed to remove the unsupported \\(u^\\star\\)-based theoretical claims, and corrected the RMSD transcription error. We also committed to revising the manuscript accordingly.\n\nSince you mentioned that you would further consider these changes during the discussion, we would greatly appreciate any final feedback on whether our response and proposed revisions address your remaining concerns. If any point is still unclear, we would be happy to clarify it promptly.\n\nThank you again for your time and careful consideration."+ },+ "createdAt": "2026-08-02T19:33:15.441Z",+ "modifiedAt": "2026-11-19T17:10:38.678Z",+ "url": "https://openreview.net/forum?id=FVSOcen7JO¬eId=PgUqQXQbMY",+ "license": "CC-BY-4.0"+}
reviews/openreview/fvsocen7jo/notes/q0z6m0rj7m.json added
+++ b/reviews/openreview/fvsocen7jo/notes/q0z6m0rj7m.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Q0z6m0Rj7m",+ "replyTo": "UXXnQQ6VH0",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 5iau",+ "content": {+ "comment": "I thank the authors for their responses and the efforts undertaken to answer my points. Three of them remain unclear:\n\n1. Force normalization. As stated in the text, the max force is normalized to O(1). Consider the case of a steric clash: is the strategy adopted compliant with the need to tame down such clashes, or is it that such cases do not happen ? A comparison between the magnitude of the forces corrected, and those observed from a force field in a MD would help.\n\n2. The claims/usefulness on u^* remains unclear. It looks like this part could be removed.\n\n3. The coherence between the paper and the rebuttal is not always unclear. For example, the first line of Table 2 is the same in the manuscript ms and the rebuttal. But the last line in Table 4 undergoes a change: from RMSD=0.99 (ms) to RMSD=0.83 in the rebuttal.\n\nAt the same time, the rebuttal does not mention a change that could explain this change.\n\nI will also ponder on the promised changes during the discussion."+ },+ "createdAt": "2026-07-30T14:24:52.299Z",+ "modifiedAt": "2026-11-19T17:10:38.862Z",+ "url": "https://openreview.net/forum?id=FVSOcen7JO¬eId=Q0z6m0Rj7m",+ "license": "CC-BY-4.0"+}
reviews/openreview/fvsocen7jo/notes/sjtdzukaro.json added
+++ b/reviews/openreview/fvsocen7jo/notes/sjtdzukaro.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "sjtdzukarO",+ "replyTo": "rAFvWIRQxC",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer 6bL9 (Sec 1)",+ "comment": "We thank the reviewer for identifying the central mechanism question: whether terminal calibration and consistency genuinely interact or merely optimize separate aspects of the model.\n\n## 1. Single-stage versus two-stage training\n\n> Line 163 suggests consistency is learned first, whereas Line 167 states joint optimization.\n\nThe implementation uses **single-stage joint optimization**:\n\n$\\mathcal L = \\alpha_{\\mathrm{init}}\\mathcal L_{\\mathrm{init}} + \\alpha_{\\mathrm{cot}}\\mathcal L_{\\mathrm{cot}} + \\alpha_{\\mathrm{cal}}\\mathcal L_{\\mathrm{cal}}.$\n\nThe phrase “Once the consistency-regularized flow is learned” is inaccurate and will be replaced by:\n\n> “During consistency regularization, we simultaneously apply terminal force-field calibration.”\n\nWe will not claim results for sequential or alternating regimes unless those experiments are completed.\n\n## 2. Could consistency imitate the teacher while calibration changes only the endpoint?\n\n> A failure mode is that consistency follows the teacher dynamics while calibration independently affects the endpoint.\n\nThis is a valid concern. The current controlled one-step results already show that the joint method exceeds consistency-only training:\n\n| Method | Validity ↑ | AAR ↑ | RMSD ↓ | Stability ↑ |\n|---|---:|---:|---:|---:|\n| Base | 19.08 | 40.27 | 3.76 | 10.69 |\n| Consistency only | 24.31 | 42.18 | 3.42 | 11.22 |\n| Joint FFC | **31.48** | **46.73** | **2.89** | **13.83** |\n\nRelative to consistency-only training, adding terminal force calibration improves validity by **7.17 points**, AAR by **4.55 points**, RMSD by **0.53 Å**, and stability by **2.61 points**. Therefore, the result cannot be explained by consistency compression alone.\n\nHowever, these numbers do not by themselves prove how far terminal supervision changes earlier-time predictions. We will therefore make the mechanism claim more modest:\n\n- $\\mathcal L_{\\mathrm{cal}}$ directly supplies terminal physical supervision;\n- $\\mathcal L_{\\mathrm{cot}}$ regularizes the same student across trajectory-paired times;\n- the observed joint gain establishes empirical complementarity, but not an analytical backward-propagation theorem.\n\n## 3. What does the equivariance theorem add?\n\n> Equivariance is already supplied by architectures such as FrameFlow.\n\nWe agree. The theorem is a preservation result, not a source of equivariance. The corrected statement is:\n\n> If $E(Qx)=E(x)$, then $F(Qx)=QF(x)$. If $v_\\theta(Qx,t)=Qv_\\theta(x,t)$, $\\bar v(Qx,t)=Q\\bar v(x,t)$, and the metric is rotation invariant, then $\\mathcal L_{\\mathrm{cal}}(Qx)=\\mathcal L_{\\mathrm{cal}}(x)$. Therefore, FFC preserves the SO(3)-equivariance of the base model.\n\nThe original text incorrectly referred to the vector field as invariant rather than equivariant. We will retitle the result **Equivariance preservation under force-field calibration**.\n\n## 4. Incorrect +0.47 improvement\n\n> The 10-step improvement is +0.13, not +0.47.\n\nThe reviewer is correct:\n\n$$\n0.80-0.67=0.13.\n$$\n\nWe will correct Table 1 and the accompanying text to **+0.13**, replace “relative improvements” with “absolute differences,” and audit all reported arithmetic.\n\nThe corrected designability gains are:\n\n- 10 steps: $0.67\\rightarrow0.80$, **+0.13**;\n- 100 steps: $0.77\\rightarrow0.83$, **+0.06**;\n- 500 steps: $0.81\\rightarrow0.85$, **+0.04**.\n\n## 5. Reward-based alignment claim\n\n> Please provide references and state the domain.\n\nWe will replace the broad statement with the more precise claim:\n\n> “Reward-based post-training has been effective in language-model preference alignment and image-generation alignment, where scalable human or automated feedback is available. Molecular design differs because wet-lab feedback is sparse, costly, and delayed, motivating differentiable physics-based surrogate signals.”\n\nWe will add representative references from language-model alignment, diffusion/image alignment, and molecular reward optimization.\n\n## 6. Sensitivity to $\\lambda_F$\n\n> The appendix suggests substantial sensitivity to the force weight.\n\nWe agree, and this should be discussed in the main paper. The appendix currently reports:\n\n- In peptide design, increasing $\\lambda_F$ from 0 to 1 improves validity, reaching a peak of **52.66%**.\n- At $\\lambda_F=10$, validity falls to **12.55%**.\n- Peptide RMSD remains near **2.07 Å** for small force weights but rises to **5.68 Å** at excessive force strength.\n- In backbone generation, designability is near **0.78** at small weights, peaks at **0.80** at $\\lambda_F=0.1$, and then decreases.\n- The selected values are $\\lambda_F=1.0$ for peptide design and $\\lambda_F=0.1$ for backbone generation, with final tuning in $[0.5,2.0]$ for the peptide setting.\n\nThese results show that FFC is not insensitive to force scaling. The defensible conclusion is:"+ },+ "createdAt": "2026-07-28T19:55:38.531Z",+ "modifiedAt": "2026-11-19T17:10:38.865Z",+ "url": "https://openreview.net/forum?id=FVSOcen7JO¬eId=sjtdzukarO",+ "license": "CC-BY-4.0"+}
reviews/openreview/fvsocen7jo/notes/sowgqujyri.json added
+++ b/reviews/openreview/fvsocen7jo/notes/sowgqujyri.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "SowGqUjyRi",+ "replyTo": "Q0z6m0Rj7m",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Thank you for the immediate response during the discussion period.",+ "comment": "We thank the reviewer for the careful follow-up. \n\n### 1. Force normalization and steric clashes\n\nWe concur that the current text does not clearly distinguish the raw molecular-mechanics force from the normalized target used for learning.\n\nThe normalized force in FFC is not intended to preserve the absolute physical force scale across different structures, nor is it interpreted as the force used for molecular-dynamics integration. Instead, it serves as a bounded directional supervision signal. The raw force field identifies which atoms and directions are responsible for reducing local strain and steric overlap, while per-structure normalization and clipping prevent a small number of extremely large clash forces from dominating the optimization.\n\nFor a severe steric clash, the corresponding raw force is typically large. After normalization, its magnitude is bounded rather than allowed to dominate the minibatch, but its direction and its relative prominence within the same structure are retained. Thus, the strategy is intended to “tame” clashes in the optimization sense: it prevents unstable gradients while still directing the generated structure away from the overlapping configuration.\n\nWe agree that this choice removes information about the absolute severity of forces across structures. This is a deliberate numerical-stability trade-off rather than a claim of physical equivalence to molecular dynamics. A direct comparison between normalized training targets and MD force magnitudes would therefore not be an apples-to-apples physical comparison, because the former are dimensionless bounded targets, whereas the latter retain physical units and depend on the MD state, temperature, constraints, and integration protocol.\n\nWe will revise the manuscript to make the following scope explicit:\n\n1. raw forces come from the molecular-mechanics potential;\n2. normalization is used only to construct a stable supervision target;\n3. the normalized force should not be interpreted as a quantitatively calibrated MD force;\n4. FFC preserves within-structure directional information but not the absolute force scale across structures.\n\nWe appreciate the reviewer for pointing out that the original wording could be read as making a stronger physical claim than intended.\n\n### 2. The \\(u^\\star\\)-based analysis\n\nWe agree with you that the \\(u^\\star\\)-based section is only an idealized fixed-target regression interpretation. It does not provide a guarantee for the practical neural-network algorithm and is not necessary to justify the method.\n\nTo avoid overstating the theoretical contribution, we will remove Assumption 2.2, Proposition 2.3, and the associated claims concerning recovery of \\(u^\\star\\) or theoretical propagation of the terminal correction along the full trajectory. The revised paper will present FFC directly through its implemented training objective and retain only the precise equivariance-preservation statement.\n\n### 3. RMSD inconsistency between the manuscript and rebuttal\n\nThanks for pointing this out. The value of **0.83 Å** in our rebuttal was an inadvertent transcription error. The result corresponding to Table 4 in the submitted manuscript and its stated evaluation protocol is **0.99 Å**:\n\n- UniMoMo-all: 1.04 Å;\n- UniMoMo-all + FFC: 0.99 Å.\n\nThere was no change in the experimental protocol or the underlying result. We apologize for introducing this inconsistency. We have corrected the rebuttal and used 0.99 Å consistently throughout the revision.\n\nWe believe that removing the unsupported theoretical claims, reconciling all reported values, and adding the raw-versus-normalized force analysis will make the method and its scope substantially clearer. If you have any further concerns, please don't hesitate to let us know."+ },+ "createdAt": "2026-07-30T20:04:23.383Z",+ "modifiedAt": "2026-11-19T17:10:38.904Z",+ "url": "https://openreview.net/forum?id=FVSOcen7JO¬eId=SowGqUjyRi",+ "license": "CC-BY-4.0"+}
reviews/openreview/fvsocen7jo/notes/t04jf81idt.json added
+++ b/reviews/openreview/fvsocen7jo/notes/t04jf81idt.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "t04jF81IdT",+ "replyTo": "UXXnQQ6VH0",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer 5iau (Sec I)",+ "comment": "We thank the reviewer for the detailed technical assessment and for noting that the approach is interesting and that the empirical results appear strong. We agree that the current presentation contains notation and rigor issues. We address each point below.\n\n## 1. Related work and the “Training” column\n\n> Previous work is not adequately discussed. Ref. [8] is not found in the main text, and it is unclear why Table 5 marks it as “No” in the Training column.\n\nWe agree. Ref. [8] should have been discussed explicitly. We will add a focused comparison explaining that trajectory-level energy-guided methods differentiate an energy objective through the generative dynamics or an adjoint construction, whereas FFC constructs a stop-gradient, force-corrected terminal target and trains the flow parameters directly. FFC therefore avoids differentiating through the full ODE trajectory and requires no force-field calls at inference.\n\nWe will also replace the ambiguous **Training** column with four explicit attributes:\n\n- whether generator parameters are updated;\n- whether an auxiliary energy/reward model is trained;\n- whether the physical evaluator is called during inference;\n- whether trajectory-level differentiation or an adjoint solver is required.\n\nThe entry for Ref. [8] will be corrected under these definitions.\n\n## 2. Comparison against competing methods\n\n> Experiments do not compare against any competing method.\n\nWe agree that this comparison was insufficiently highlighted. Table 3 already compares FFC against four matched alternatives using the **same PepFlow backbone, same one-step sampling regime, and same evaluation set of 158 complexes**:\n\n| Method | Validity ↑ | AAR ↑ | RMSD ↓ | Stability ↑ | Time/sample ↓ |\n|---|---:|---:|---:|---:|---:|\n| PepFlow | 19.08 | 40.27 | 3.76 | 10.69 | 0.05 s |\n| + Consistency only | 24.31 | 42.18 | 3.42 | 11.22 | 0.05 s |\n| + Inference-time forces | 22.47 | 41.63 | 3.51 | 12.84 | 1.52 s |\n| + Idempotent flow | 26.15 | 43.91 | 3.28 | 11.87 | 1.46 s |\n| + Energy conditioning | 28.52 | 44.85 | 3.08 | 12.43 | 0.07 s |\n| + FFC | **31.48** | **46.73** | **2.89** | **13.83** | **0.05 s** |\n\nRelative to the uncalibrated model, FFC improves one-step validity by **12.40 percentage points**, AAR by **6.46 points**, RMSD by **0.87 Å**, and stability by **3.14 points**. Relative to the strongest competing one-step baseline, energy conditioning, FFC improves validity by **2.96 points**, AAR by **1.88 points**, RMSD by **0.19 Å**, and stability by **1.40 points**. Inference-time forces require **1.52 s/sample**, approximately **30.4×** the 0.05 s/sample cost of FFC.\n\nWe will move this table and its interpretation into the main comparison discussion. We will not claim a matched RL/GFlowNet comparison unless such a baseline is implemented under the same task, architecture, and reward.\n\n## 3. Force normalization and Eq. (4)\n\n> For a very large force on one atom, the written correction appears to attenuate that force toward zero.\n\nThe reviewer is correct that the written equation is ambiguous and can be read as applying two magnitude-dependent attenuations. We will replace it with the exact implemented sequence:\n\n$F_i^{\\mathrm{norm}} = \\frac{F_i}{\\max_j\\|F_j\\|+\\epsilon}$,\n\nfollowed by clipping in normalized space,\n\n$ \\widetilde F_i = F_i^{\\mathrm{norm}} \\min\\left(1, \\frac{c}{\\|F_i^{\\mathrm{norm}}\\|+\\epsilon} \\right). $\n\nThus, the largest force is normalized to $O(1)$ and then bounded; it does not converge toward zero merely because the original raw force is large. We will verify the manuscript equation against the released implementation and state the clipping threshold explicitly.\n\nThe existing robustness observation will also be stated more carefully: replacing per-structure normalization with a global normalization produced nearly identical performance in our implementation, but the manuscript should not imply invariance to arbitrary force preprocessing.\n\n## 4. Eq. (7): tangent to the geodesic\n\n> Replace $g(x_0,x_1)$ by the tangent to the geodesic.\n\nWe agree. A scalar geodesic distance cannot serve as a velocity target. The corrected objective is\n\n$\\mathcal L_{\\mathrm{init}}=\\left\\| v_\\theta(x_0,0) - \\mathrm{Log}_{x_0}(x_1)\\right\\|_g^2,$\n\nwhere $\\mathrm{Log}_{x_0}(x_1)\\in T_{x_0}\\mathcal M$ is the tangent of a shortest geodesic. For the modeled components, this becomes:\n\n- Euclidean positions: $x_1-x_0$;\n- rotations: $\\mathrm{Log}_{O_0}(O_1)$;\n- torsions: the shortest wrapped angular displacement.\n\nWe will distinguish the geodesic distance $d_g$, logarithm map $\\mathrm{Log}$, and tangent norm $\\|\\cdot\\|_g$ throughout."+ },+ "createdAt": "2026-07-28T19:41:53.950Z",+ "modifiedAt": "2026-11-19T17:10:38.876Z",+ "url": "https://openreview.net/forum?id=FVSOcen7JO¬eId=t04jF81IdT",+ "license": "CC-BY-4.0"+}
reviews/openreview/fvsocen7jo/notes/vkzjhtxflj.json added
+++ b/reviews/openreview/fvsocen7jo/notes/vkzjhtxflj.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "vKzjHtXfLJ",+ "replyTo": "t04jF81IdT",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer 5iau (Sec II)",+ "comment": "## 5. Complete backpropagation pseudocode\n\n> Please provide pseudocode for backpropagation.\n\nFFC uses single-stage joint optimization:\n\n```text\nInputs:\n trainable student v_theta\n frozen/EMA teacher v_bar\n differentiable reconstruction zeta\n relaxation operator Relax\n force evaluator F\n\nFor each minibatch:\n 1. Sample clean state z_1 and prior state z_0.\n 2. Sample 0 <= t < r < 1 and construct z_t, z_r\n on the same teacher trajectory.\n 3. L_init = ||v_theta(z_0,0) - Log_{z_0}(z_1)||_g^2.\n 4. target_cot = stopgrad[v_bar(z_r,r)].\n 5. L_cot = w(t,r)||v_theta(z_t,t)-target_cot||_g^2.\n 6. Generate the student terminal state zhat_1.\n 7. yhat_1 = zeta(zhat_1).\n 8. yrelax_1 = stopgrad[Relax(yhat_1)].\n 9. Ftilde = stopgrad[NormalizeClip(F(yrelax_1))].\n 10. ytarget = stopgrad[yteacher_1 + lambda_F Ftilde].\n 11. L_cal = ||zeta(zhat_1)-ytarget||_g^2.\n 12. Update theta using\n L = alpha_init L_init + alpha_cot L_cot + alpha_cal L_cal.\n 13. Update the EMA teacher, when used.\n```\n\nNo gradient is propagated through the teacher target, relaxation, force evaluation, or pseudo-target construction. Gradients flow through the student and through $\\zeta$ on the student side of $\\mathcal L_{\\mathrm{cal}}$.\n\n## 6. Eq. (10)\n\n> Eq. 10 appears false because setting $t=1$ gives an implausible conclusion.\n\nWe agree. Eq. (10) is incorrect as written and derive the algorithm, choose hyperparameters, or compute any reported result. Removing the erroneous bound therefore does not alter the method or empirical conclusions. \n\nThe revised paper will make only the following limited statement: because $\\mathcal L_{\\mathrm{cot}}$ and $\\mathcal L_{\\mathrm{cal}}$ optimize the same student parameters, joint training couples trajectory-paired predictions with terminal physical supervision. This is an empirical mechanism, not a formal guarantee that a terminal perturbation is analytically propagated backward. \n\n## 7. Torsion-angle interpolation\n\n> The expression for $\\phi_t^{\\mathrm{ang}}$ does not account for the two paths on $S^1$.\n\nThe corrected interpolation is $ \\Delta \\chi = \\mathrm{wrap}_{[-\\pi,\\,\\pi)} (\\chi_1-\\chi_0 ). $\nThe angular interpolation is then \n\n $\\phi_t^{\\mathrm{ang}} = \\mathrm{wrap}_{[0, 2\\pi)} (\\chi_0+t \\Delta \\chi). $\n\nEquivalently,\n$e^{i\\phi_t^{\\mathrm{ang}}} = e^{i\\chi_0}e^{it\\Delta\\chi}. $\n\nThis selects a shortest wrapped displacement, except at the measure-zero antipodal ambiguity.\n\n## 8. Reconstruction module $\\zeta$: coordinates versus vectors\n\n> The pseudocode says $\\zeta$ returns coordinates, while the equations appear to require vectors.\n\nWe agree that the manuscript mixes a conceptual terminal-velocity interpretation with the practical Cartesian objective. In the implementation,\n\n$ y_\\theta=\\zeta(z_{\\theta,1}), y_{\\mathrm{target}} = \\mathrm{sg} \\left[ y_{\\mathrm{teacher}} + \\lambda_F\\widetilde F(\\widetilde y_1) \\right],$\n\nand\n\n$ \\mathcal L_{\\mathrm{cal}} = \\|y_\\theta-y_{\\mathrm{target}}\\|_g^2.$\n\nThus, $\\zeta$ maps multimodal latent variables to Cartesian coordinates. Gradients pass through the student-side Jacobian of $\\zeta$ to positions, orientations, and torsions. The teacher, relaxation, force, and pseudo-target branches are stop-gradient. We will clearly separate this implemented Cartesian displacement target from the motivating velocity-field description.\n\n## 9. Existence and non-uniqueness of $u^\\star$\n\n> Assumption 2.2 states only that a calibrated field exists, while Proposition 2.3 appears to imply uniqueness.\n\nWe agree. Multiple vector fields may transport $q_0$ to the same terminal distribution. The corrected proposition will be conditional:\n\n> Let $u^\\star$ be any fixed admissible reference field satisfying Assumption 2.2. Conditional on this chosen field and its path measure, the quadratic functional $ \\mathcal L(v)=\\frac{1}{2}\\|v-u^\\star\\|_{\\mathcal H}^2 $ has the unique minimizer $v=u^\\star$.\n\nThis does **not** establish uniqueness of the transport associated with the energy-biased terminal distribution. We will remove “unique calibrated flow,” “recovers the calibrated flow,” and “rules out spurious minima” when describing the practical neural-network problem. The section will be retitled **Idealized fixed-target regression interpretation**.\n\n## 10. Connection between the idealized theory and practical FFC\n\n> The logical links between assumptions, equations, and conclusions are unclear.\n\nWe explicitly distinguish:\n\n| Idealized object | Practical surrogate |\n|---|---|\n| Fixed calibrated field $u^\\star$ | Force-corrected teacher terminal target |\n| Path marginals $q_t^\\star$ | Teacher/student sampled trajectories |\n| Full-path $L^2$ regression | Terminal calibration plus consistency regularization |\n| Exact functional optimization | Neural-network SGD |\n\nFFC is motivated by this regression view but is not mathematically equivalent to the inaccessible full-path objective. We will not claim exact recovery of $u^\\star$ or of the Gibbs-reweighted terminal distribution."+ },+ "createdAt": "2026-07-28T19:42:25.669Z",+ "modifiedAt": "2026-11-19T17:10:38.867Z",+ "url": "https://openreview.net/forum?id=FVSOcen7JO¬eId=vKzjHtXfLJ",+ "license": "CC-BY-4.0"+}
reviews/openreview/fvsocen7jo/notes/xy7gk3tjet.json added
+++ b/reviews/openreview/fvsocen7jo/notes/xy7gk3tjet.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "XY7gK3TJET",+ "replyTo": "sjtdzukarO",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Reviewer 6bL9 (Sec 2)",+ "comment": "> Moderate force supervision improves physical quality, whereas excessive force strength overwhelms the learned generative prior and degrades geometry. $\\lambda_F$ is therefore a task-level calibration hyperparameter rather than a universally transferable constant.\n\nWe will move this discussion into the main text and avoid describing the method as broadly robust without qualification.\n\n## 7. Which component does the heavy lifting?\n\n> Is the improvement mainly caused by calibration, and can calibration be isolated from consistency?\n\nThe existing one-step ablation shows:\n\n- consistency-only versus base: validity **+5.23**, AAR **+1.91**, RMSD **−0.34 Å**, stability **+0.53**;\n- joint FFC versus consistency-only: validity **+7.17**, AAR **+4.55**, RMSD **−0.53 Å**, stability **+2.61**;\n- joint FFC versus base: validity **+12.40**, AAR **+6.46**, RMSD **−0.87 Å**, stability **+3.14**.\n\nThis indicates that force calibration supplies the larger share of the observed one-step physical-quality gain, while consistency alone also improves few-step generation.\n\nThe submitted experiments do not contain a clean **calibration-only without consistency** row. We will therefore not fabricate that result. We will state this as an important missing ablation and, if completed during rebuttal, report it separately with its exact training protocol.\n\n## 8. Is terminal-only regression sufficient?\n\n> Compare terminal-only calibration with differentiating through the last few trajectory steps.\n\nWe agree that this is a valuable diagnostic. The submitted manuscript does not contain a controlled last-$K$-step backpropagation experiment, so we will not insert unsupported numbers.\n\nOur present evidence supports only the narrower practical claim: terminal calibration plus joint consistency improves one-step and multi-step sampling without differentiating through the ODE trajectory. For example:\n\n| Steps | Base validity | FFC validity | Base RMSD | FFC RMSD |\n|---:|---:|---:|---:|---:|\n| 1 | 19.08 | **31.48** | 3.76 | **2.89** |\n| 2 | 26.72 | **34.92** | 3.53 | **2.64** |\n| 5 | 29.59 | **38.66** | 3.43 | **2.41** |\n| 10 | 33.10 | **41.83** | 3.02 | **2.17** |\n| 200 | 40.27 | **56.83** | 2.07 | **1.97** |\n\nFFC improves validity at every sampling budget by **8.20–16.56 percentage points** and lowers RMSD by **0.10–1.02 Å**. These results demonstrate effectiveness, but they do not establish optimality relative to last-$K$-step differentiation.\n\n## 9. Revised description of consistency\n\nWe will avoid saying that consistency “provably transports” the force correction backward. The revised explanation is:\n\n- $\\mathcal L_{\\mathrm{cal}}$ directly supervises the terminal physical target;\n- $\\mathcal L_{\\mathrm{cot}}$ regularizes trajectory-paired predictions of the same student;\n- joint optimization empirically produces better one-step and multi-step samples than either the uncalibrated base or consistency-only training;\n- no theorem is claimed for exact backward propagation of the terminal correction."+ },+ "createdAt": "2026-07-28T19:55:52.288Z",+ "modifiedAt": "2026-11-19T17:10:38.839Z",+ "url": "https://openreview.net/forum?id=FVSOcen7JO¬eId=XY7gK3TJET",+ "license": "CC-BY-4.0"+}