potentialpaper

Equivariant Force Field Calibration for Flow-based Protein Design

Import NeurIPS 2026 submission FVSOcen7JO: 5 notes

@openreview[bot] · 2026-11-22 17:55 UTC · a85db8efea55

Evidence

.gitattributes added

+++ b/.gitattributes
@@ -0,0 +1,10 @@
+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),
+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.
+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text
+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text
+/thumbnail.png filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text
+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text
+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text
+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text

.potentialpaper/metadata.json added

+++ b/.potentialpaper/metadata.json
@@ -0,0 +1,21 @@
+{
+ "layout": 5,
+ "identifiers": [
+ {
+ "scheme": "openreview",
+ "value": "FVSOcen7JO"
+ }
+ ],
+ "title": "Equivariant Force Field Calibration for Flow-based Protein Design",
+ "authors": [
+ "Fang Wu"
+ ],
+ "abstract": "Flow models show promise for molecular design due to their fast, expressive sampling capabilities. However, their applicability to complex biological systems remains limited by a lack of physical grounding, which leads to unrealistic or unstable molecular structures.\nThis work presents a framework that integrates force field guidance with consistency-based training to improve the physical fidelity of flow-based generative models. We calibrate pretrained flow models using differentiable physical energy functions to steer generation toward low-energy and sterically valid conformations. A consistency-based training strategy enables accurate, robust generation with very few sampling steps, improving inference efficiency. We evaluate it on three protein design tasks: unconditional backbone generation, full-atom peptide binder co-design, and antibody CDR-H3 redesign. Experiments show that our approach consistently improves physical plausibility and geometric stability, while enabling favorable trade-offs between structural diversity and computational cost. By unifying physical calibration and efficient sampling, we advance the scalability and reliability of flow-based molecular generation.",
+ "year": 2026,
+ "venue": "NeurIPS 2026",
+ "source": "openreview",
+ "license": {
+ "metadata": "CC0-1.0",
+ "abstract": "CC0-1.0"
+ }
+}

community/10-tl-dr.md added

+++ b/community/10-tl-dr.md

community/20-summary.md added

+++ b/community/20-summary.md

community/30-why-it-matters.md added

+++ b/community/30-why-it-matters.md

community/40-critique.md added

+++ b/community/40-critique.md

community/50-errata.md added

+++ b/community/50-errata.md

community/60-reproductions.md added

+++ b/community/60-reproductions.md

community/70-follow-ups.md added

+++ b/community/70-follow-ups.md

owners/10-tl-dr.md added

+++ b/owners/10-tl-dr.md

owners/20-overview.md added

+++ b/owners/20-overview.md

owners/30-results.md added

+++ b/owners/30-results.md

owners/40-demos.md added

+++ b/owners/40-demos.md

owners/50-code-and-data.md added

+++ b/owners/50-code-and-data.md

owners/60-talks.md added

+++ b/owners/60-talks.md

prek.toml added

+++ b/prek.toml
@@ -0,0 +1,36 @@
+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.
+# The site checks every push again; these catch mistakes before you commit. The same on every page.
+
+[[repos]]
+repo = "builtin"
+hooks = [
+ { id = "check-json" },
+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },
+ { id = "end-of-file-fixer", exclude = '^demos/' },
+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },
+ { id = "check-case-conflict" },
+ { id = "check-illegal-windows-names" },
+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },
+]
+
+# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).
+[[repos]]
+repo = "https://github.com/python-jsonschema/check-jsonschema"
+rev = "0.39.0"
+hooks = [
+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },
+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },
+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },
+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },
+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },
+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },
+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },
+]
+
+# Sections formatted the way the web editor formats them.
+[[repos]]
+repo = "https://github.com/rbubley/mirrors-prettier"
+rev = "v3.9.9"
+hooks = [
+ { id = "prettier", files = '^(owners|community)/.*\.md$' },
+]

reviews/openreview/fvsocen7jo/forms.json added

+++ b/reviews/openreview/fvsocen7jo/forms.json
@@ -0,0 +1,227 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ },
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "quality",
+ "clarity",
+ "significance",
+ "originality"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 6
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 5
+ },
+ {
+ "key": "quality",
+ "label": "Quality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "clarity",
+ "label": "Clarity",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "significance",
+ "label": "Significance",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "originality",
+ "label": "Originality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "contribution_type",
+ "label": "Contribution type",
+ "type": "choice"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "strengths_and_weaknesses",
+ "label": "Strengths and weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions",
+ "label": "Questions",
+ "type": "text"
+ },
+ {
+ "key": "limitations",
+ "label": "Limitations",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ },
+ {
+ "key": "paper_formatting_concerns",
+ "label": "Formatting concerns",
+ "type": "text"
+ },
+ {
+ "key": "ethical_concerns",
+ "label": "Ethical concerns",
+ "type": "choice"
+ },
+ {
+ "key": "code_of_conduct_acknowledgement",
+ "label": "Code of conduct",
+ "hidden": true
+ },
+ {
+ "key": "responsible_reviewing_acknowledgement",
+ "label": "Responsible reviewing",
+ "hidden": true
+ }
+ ]
+ },
+ "Rebuttal": {
+ "label": "Rebuttal",
+ "fields": [
+ {
+ "key": "rebuttal",
+ "label": "Rebuttal",
+ "type": "text"
+ }
+ ]
+ },
+ "Ethics_Review": {
+ "label": "Ethics review",
+ "fields": [
+ {
+ "key": "scope_of_ethics_concerns",
+ "label": "Scope",
+ "type": "choice"
+ },
+ {
+ "key": "ethics_review",
+ "label": "Ethics review",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fvsocen7jo/notes/iw5oefhwhy.json added

+++ b/reviews/openreview/fvsocen7jo/notes/iw5oefhwhy.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "iW5OefhwhY",
+ "replyTo": null,
+ "kind": "meta_review",
+ "invitation": "Meta_Review",
+ "signature": "Area Chair idLL",
+ "content": {
+ "metareview": "This paper presents FFC, a method that calibrates a pretrained flow model toward physically valid conformations by aligning its terminal velocity to a differentiable force-field gradient, coupled with a consistency-based training strategy for few-step sampling; it is evaluated on unconditional protein, peptide, and antibody design. Reviewers agree the central idea is interesting, applying the force field at the terminal state neatly sidesteps the problem of scoring non-physical intermediate objects. The disagreement is about theoretical rigor and evaluation completeness. I recommend the authors to address the following problems: \n\n1. Absence of baselines (especially other force field guidance methods). Two reviewers flagged that experiments compare only FFC vs. no-FFC on each base model. However, the introduction of this paper mentioned a lot of related force field guidance / calibration methods. Even though the results in the paper looks good, it is unclear whether the proposed FFC method is better than prior related work. Also, the unconditional protein backbone generation doesn't have any baseline (unless I missed it). Besides absolute performance, the authors should also report sampling efficiency of FFC and compare with previous energy guidance methods.\n\n2. There seem to be some problems in the derivation of FFCs (as flagged by two reviewers). Also, it's unclear whether the consistency flow is learned first and then calibrated (\"once the consistency-regularized flow is learned…\") or jointly optimized, and a reviewer raises a specific failure mode: the consistency loss merely tracking the teacher while calibration independently adjusts the endpoint."
+ },
+ "createdAt": "2026-07-26T10:16:03.548Z",
+ "modifiedAt": "2026-11-18T15:21:28.896Z",
+ "url": "https://openreview.net/forum?id=FVSOcen7JO&noteId=iW5OefhwhY",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fvsocen7jo/notes/rafvwirqxc.json added

+++ b/reviews/openreview/fvsocen7jo/notes/rafvwirqxc.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "rAFvWIRQxC",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer 6bL9",
+ "content": {
+ "summary": "This work proposes FFC, which integrates force field guidance with a pretrained flow model to steer generation toward low-energy and sterically valid conformations. A consistency flow model is learned from a pretrained flow model followed by the force field calibration where a differentiable reward model is used for gradient-based calibration of the terminal velocity. Experiments are conducted for unconditional protein design, peptide design and antibody design.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "The paper addresses an important need of current generative models for biological sequence/molecule design, which is the integration of physically grounded constraints into the training and generation process. \n\nHowever, in its current state the paper has still some weaknesses that I will discuss below. \n\n\nOn the one-step vs. two-step training regime of the consistency loss and the calibration loss. In line 163 it is written “Once the consistency-regularized flow is learned...”, but in the next paragraph the authors state that they jointly optimize over the consistency and calibration loss (Line 167). Please clarify what training regime was used; and consider providing an ablation over the training dynamics. \n\nIn general, the trajectory gets shaped such that the terminal velocity sits in a good place for calibration, rather than the calibration fighting a fixed trajectory at the very end. I believe this would only work with the joint loss (line 167) and not be a subsequent optimization (line 163). The failure mode on the other hand would be that the consistency loss just adheres closely to the teacher dynamics and the calibration loss independently works on the endpoint velocity. Is there any reason to assume that this is not the case? \nPlease clarify and discuss this further. \n\nIn line 171, the authors write on the equivariance of the calibration loss, which in Theorem 2.1 is shown to give an invariant loss under the assumption that vθ is invariant. If I am not mistaken, this property is already given by the model architecture (eg FrameFlow is SO(3)-equivariant by construction), not by FFC, so I would appreciate a discussion on what this theorem adds beyond what the pretrained base flow model already gives us.\n\nIn Table 1 first row, first column for 10 timesteps the increase using FFC is not 0.47 but 0.13 (and in Line 293). This is a discrepancy and needs to be clarified to avoid false statements. \n\nLine 72-73: please provide some example references and state the domain that the claim holds for. \n\nThe ablation in Section H App. suggests that the setup is very sensitive wrt $\\lambda_F$, which controls the influence of the force field model. This should be discussed in more detail, also in the main paper.\n\nPlease correct me if I missed it, but is there an ablation or experiment to dissect which of the components (consistency vs. force field calibration) does the heavy lifting and yields the performance boost? One would imagine it is the calibration loss. If this is the case, is it then also possible to isolate it and apply it to a pretrained flow model without the separate consistency model or a few-step model in general?\n\nAn ablation on regressing the terminal velocity only could also be very useful to convince the reader that this is sufficient. It could be compared to taking the last steps of the trajectory (at the cost of backpropagating through them).",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 3,
+ "questions": "I recommend the authors focus on the following points:\n- Training regimes of one-step vs. two-step discrepancy\n- Detailed ablations on consistency vs. calibration, as well as evaluating the sufficiency of the terminal velocity for the calibration loss\n- Metrics reporting, wrt discrepancy of the increase by FFC (Table 1)\n- Theorem 2.1. equivariance clarification",
+ "limitations": "Yes",
+ "rating": 4,
+ "confidence": 3,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "None that I noticed.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "I thank the authors for their detailed responses. They have addressed my questions and concerns where possible given the timeframe of the rebuttal period.\nI appreciate the authors' commitment to revising some of their claims and updating Table 1 accordingly. I will take these responses and promised updates into account during the final discussion."
+ },
+ "createdAt": "2026-06-10T10:18:28.408Z",
+ "modifiedAt": "2026-11-18T13:39:33.929Z",
+ "url": "https://openreview.net/forum?id=FVSOcen7JO&noteId=rAFvWIRQxC",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fvsocen7jo/notes/tpsw3gd5ct.json added

+++ b/reviews/openreview/fvsocen7jo/notes/tpsw3gd5ct.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "TpSw3gd5Ct",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer Wrss",
+ "content": {
+ "summary": "This paper introduces a technique (FCC) to align a pretrained flow-matching model to a physical energy function. This is done by regressing the terminal velocity function to a force-field model and interleaving training with a consistency loss. The paper evaluates the method on unconditional protein design, peptide design, and antibody design fine-tuning 3 different models and comparing with and without FCC. The authors show improved performance in all three tasks.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "Overall, I thought this paper was very good and warrants acceptance. I thought aligning the terminal velocity to the force field was quite clever: I would expect the force-field to most accurate near a terminal state of the flow-matching process, and by aligning only at the terminal state, this approach should get around the problem of applying a force-field to a non-physical object. The rest of the method builds on prior work, and the results are quite strong.\n\nThere are some minor weaknesses of the paper. The theoretical section largely provides intuition and it’s not clear how well the argument holds when u* and q_t* are not accessible. Empirically, there is a fairly consistent decline in diversity with FCC that are not fully explored. I am also curious how well FCC compares to RL (or related methods) of a flow-matching model on an energy function. Specifically, I wonder how FCC compares to a method like AbFlowNet, which uses a GFlowNet on a similar problem. \n\nMinor\n1. Equation 1 implies that an explicit, differentiable energy function is needed but that’s not true. Subsequent equations use a force-field \n2. It's unclear where the locally relaxed structure \\tilde{x}_1 is used. This seems like a notational problem\n3. Shouldn't the force field in equation 2 be corrected to account for the relaxation step?",
+ "quality": 4,
+ "clarity": 4,
+ "significance": 3,
+ "originality": 4,
+ "questions": "1. A comparison between FCC and an RL or GFlowNet model.\n2. An analysis of why diversity falls for generated proteins.",
+ "limitations": "None were presented",
+ "rating": 5,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "none",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "My assessment of this paper has not changed during the review period. Overall, I think this is a strong paper and while the other reviewers have pointed out some weaknesses in the presentation of the results, I don't think these issues change my view of the paper. Specifically, I am less concerned about the comparison against other methods on the presented tasks (pointed out by both me and reviewer 5iau), as I view the method in and of itself worthy of publication."
+ },
+ "createdAt": "2026-06-22T21:04:31.973Z",
+ "modifiedAt": "2026-11-18T13:39:31.914Z",
+ "url": "https://openreview.net/forum?id=FVSOcen7JO&noteId=TpSw3gd5Ct",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fvsocen7jo/notes/uxxnqq6vh0.json added

+++ b/reviews/openreview/fvsocen7jo/notes/uxxnqq6vh0.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "UXXnQQ6VH0",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer 5iau",
+ "content": {
+ "summary": "This paper studies flow models to generate protein sequences+conformations. The approach is named 'Force Field guided Calibration' (FFC). The idea is to 'fix/amend' the vector field of a flow model using a prior, e.g. the gradient of a molecular potential energy, so as to improve the quality of the designed molecules.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "The approach is interesting and the results appear very good.\n\nPrevious work is not adequately discussed. For example, ref [8] is not found in the main text. in addition, I do not understand why Table [5] qualifies it with No in the Training column.\n\nFrom the theory standpoint, the presentation is sloppy and lacks rigor in many places, jeopardizing the overall piece of work.\n\nExperiments do not compare against *any* competing method, nor do they explain why such a comparison is not feasible.\n\nWith a proper/rigorous presentation of the method and a benchmark against alternatives, this could be a great piece of work.",
+ "quality": 2,
+ "clarity": 2,
+ "significance": 2,
+ "originality": 2,
+ "questions": "## Theory\n\n* Smoothing forces in a pre-treatment. Eq.(4) is suspicious, as seen by considering the case of a single steric clash between atoms i and j.\nIf ||F_i|| is huge, then the corrected \\tilde F_i is close to 0. that is, the proposed correction appears to aggressive. please explain.\n\n* Eq (7): replace g(x_0,x_1) by the tangent to the geodesic.\n\n* In a nutshell, the losses used can be segregated into three groups: (1) the loss \\calL_init (Eq. 8) which measures the discrepancy between v_\\theta and the tangent to a geodesic joining two samples (2) the loss \\calL_cfc for the total consistency flow calibration (3) the terminal calibration at t=1. please provide the pseudo-code for the back propagation, which is critical. as of now, understanding this back-propagation is very difficult.\n\n* Equation 10 appears to be false: plugging t=1 yields v_\\theta = \\bar{v}, which is not plausible.\n\n* Multi-modality flow on torsion angles. the expression \\phi_t^{ang} cannot be correct since the ordering is not taken into account -- there are two paths joining two angles on S^1. also, using complex numbers, how come we do not have : phi^{ang} (t) = phi^{ang}(0) * exp( i * t(delta theta) )?\n\n* Function \\zeta defining the 'differentiable reconstruction module'. the pseudo-code in SI show that this function returns coordinates, but the equation line 227 requires vectors -- as also requires by Eq. (8). your notations are not consistent.\n\n* Theoretical analysis. The assumption 2.2 states \"there exists u^*\", which is fine. but proposition 2.3 does not mention which u^* is concerned !!!\n\nLikewise, in Section 2.6, the text \"in which u^* is recovered...\" seems to imply u^* is unique, which is not the case.\n\nIn general in Section 2.6, the logical links between assumptions - equations - conclusion are not clear at all.\n\n* Appendix : Table 6, L_prog is not defined.\n\n\n## Applications\n\n* The results look very good overall, congrats. but the lack of details makes it very hard to know what we are talking about.\n\n* Protein design. explain why the number of clusters is worse using FFC. also explain how the number of clusters is determined: is this some kind of 'elbow curve' criterion applied to backbones ? it would also be nice to have a 2D embedding based on MDS (using pairwise distances between backbones), to see whether these clusters make sense. as of now, interpreting this statistic is impossible.\n\n* Antibody design. are you processing single domain antibodies (6 CDRs), or nanobodies (3 CDRs)? this changes the size of the context.\nalso, please define AAR and RMSD carefully.\n\nFor AAR, I assume you are talking about 'amino acid recall' or the like ? if so, this is a 'identity' rather than 'homology' statistic ? if this is the case, the 'homology' statistic obtained using a Blosum matrix is required. indeed, trading D for E or K for K (or H) is not significant. (NB: I am using 1 letter amino acid symbols).\n\nFor RMSD, I am assuming this is a RMSD computed on the (N, CA, C (O?)) atoms ? I guess it has to be so since the a.a. may have changed with respect to the CDR removed.\n\nFinally, also report in SI the mutations observed.",
+ "limitations": "Yes.",
+ "rating": 2,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "None.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The paper was really too far from being polished, and there are too many promises in the changes foreseen. A journal submission with another serious review round is mandatory for me."
+ },
+ "createdAt": "2026-06-26T08:47:26.676Z",
+ "modifiedAt": "2026-11-18T13:39:30.593Z",
+ "url": "https://openreview.net/forum?id=FVSOcen7JO&noteId=UXXnQQ6VH0",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fvsocen7jo/notes/ywb1ayhvyw.json added

+++ b/reviews/openreview/fvsocen7jo/notes/ywb1ayhvyw.json
@@ -0,0 +1,19 @@
+{
+ "schema": "review/1",
+ "id": "ywB1AYHVyw",
+ "replyTo": null,
+ "kind": "decision",
+ "invitation": "Decision",
+ "signature": "Program Chairs",
+ "content": {
+ "title": "Paper Decision",
+ "decision": "Accept (poster)",
+ "comment": "",
+ "metareview": "This paper presents FFC, a method that calibrates a pretrained flow model toward physically valid conformations by aligning its terminal velocity to a differentiable force-field gradient, coupled with a consistency-based training strategy for few-step sampling; it is evaluated on unconditional protein, peptide, and antibody design. Reviewers agree the central idea is interesting, applying the force field at the terminal state neatly sidesteps the problem of scoring non-physical intermediate objects. The disagreement is about theoretical rigor and evaluation completeness. I recommend the authors to address the following problems: \n\n1. Absence of baselines (especially other force field guidance methods). Two reviewers flagged that experiments compare only FFC vs. no-FFC on each base model. However, the introduction of this paper mentioned a lot of related force field guidance / calibration methods. Even though the results in the paper looks good, it is unclear whether the proposed FFC method is better than prior related work. Also, the unconditional protein backbone generation doesn't have any baseline (unless I missed it). Besides absolute performance, the authors should also report sampling efficiency of FFC and compare with previous energy guidance methods.\n\n2. There seem to be some problems in the derivation of FFCs (as flagged by two reviewers). Also, it's unclear whether the consistency flow is learned first and then calibrated (\"once the consistency-regularized flow is learned…\") or jointly optimized, and a reviewer raises a specific failure mode: the consistency loss merely tracking the teacher while calibration independently adjusts the endpoint.",
+ "final_justification": "All reviewers have read authors response. Two reviewers remain very positive of the paper, while one reviewer had opposite view. AC has gone through the author response and found that authors have provided sufficient comparison with other guidance methods during rebuttal and additional baseline. While some minor issues remain, the main concern have been addressed. Therefore, AC recommends acceptance."
+ },
+ "createdAt": "2026-09-24T11:20:49.848Z",
+ "modifiedAt": "2026-11-18T14:55:08.371Z",
+ "url": "https://openreview.net/forum?id=FVSOcen7JO&noteId=ywB1AYHVyw",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/fvsocen7jo/submission.json added

+++ b/reviews/openreview/fvsocen7jo/submission.json
@@ -0,0 +1,12 @@
+{
+ "schema": "submission/1",
+ "id": "FVSOcen7JO",
+ "venue": {
+ "id": "NeurIPS.cc/2026/Conference",
+ "name": "NeurIPS 2026",
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"
+ },
+ "number": 14880,
+ "url": "https://openreview.net/forum?id=FVSOcen7JO",
+ "license": "CC-BY-4.0"
+}

versions/v_frai2r8p.json added

+++ b/versions/v_frai2r8p.json
@@ -0,0 +1,22 @@
+{
+ "date": "2026-05-02",
+ "kind": "submitted",
+ "label": "NeurIPS 2026",
+ "submissions": [
+ {
+ "venue": "NeurIPS 2026",
+ "status": "accepted",
+ "decision": "Accept (poster)",
+ "number": 14880,
+ "url": "https://openreview.net/forum?id=FVSOcen7JO",
+ "reviews": "openreview/fvsocen7jo",
+ "evidence": [
+ "https://openreview.net/forum?id=FVSOcen7JO"
+ ]
+ }
+ ],
+ "url": "https://openreview.net/forum?id=FVSOcen7JO",
+ "evidence": [
+ "https://openreview.net/forum?id=FVSOcen7JO"
+ ]
+}